Tech Sheet Do not discard W10249266A / 461965199723 FOR SERVICE TECHNICIAN’S USE ONLY PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY a. Do not operate or allow the oven to be operated with the door open. b. Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary: 1. Interlock Operation 2. Proper Door Closing 3. Seal and Sealing Surfaces (Arcing, Wear and Other Damage) 4. Damage to or Loosening of Hinges and Latches 5. Evidence of Dropping or Abuse c. Before turning on microwave power for any service test or inspection within the microwave generating compartments, check the magnetron, waveguide or transmission line, and cavity for proper alignment, integrity and connections. d. Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation and transmission systems shall be repaired, replaced, or adjusted by procedures described in service manual before the oven is released to the owner. e. A microwave leakage check to verify compliance with the CSA should be performed on each oven prior to release to the owner. f. Do not attempt to operate the oven if the door glass is broken. WARNING Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock.

Upload: others

Post on 27-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PRECAUTIONS TO BE OBSERVED BEFORE AND DURING … · 2016. 7. 5. · 4901 TT L.V. BR Transformer H.V. Transformer BU Cavity Light CL P5-2 R GY W BK Filter Board BU OR P5-4 HF Relay

Tech Sheet Do not discard

W10249266A / 461965199723 FOR SERVICE TECHNICIAN’S USE ONLY

PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE

EXPOSURE TO EXCESSIVE MICROWAVE ENERGYa. Do not operate or allow the oven to be operated with the

door open.b. Make the following safety checks on all ovens to be serviced

before activating the magnetron or other microwave source, and make repairs as necessary:

1. Interlock Operation2. Proper Door Closing3. Seal and Sealing Surfaces (Arcing, Wear and Other Damage)4. Damage to or Loosening of Hinges and Latches5. Evidence of Dropping or Abuse

c. Before turning on microwave power for any service test or inspection within the microwave generating compartments, check the magnetron, waveguide or transmission line, and cavity for proper alignment, integrity and connections.

d. Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation and transmission systems shall be repaired, replaced, or adjusted by procedures described in service manual before the oven is released to the owner.

e. A microwave leakage check to verify compliance with the CSA should be performed on each oven prior to release to the owner.

f. Do not attempt to operate the oven if the door glass is broken.

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

Page 2: PRECAUTIONS TO BE OBSERVED BEFORE AND DURING … · 2016. 7. 5. · 4901 TT L.V. BR Transformer H.V. Transformer BU Cavity Light CL P5-2 R GY W BK Filter Board BU OR P5-4 HF Relay

2

WIRING DIAGRAMSSchematic Diagram

Cy

Cy

Cx

R

L

AC 120V 60HzPower Cord

Cav

ity Th

erm

osta

t 1BU

Whi

teTa

b

Gol

den

Tab

Dio

de 6

101

Cav

ity T

herm

osta

t 2

P5-4

AC L

ine

Filt

er B

oard

LBK

BK

G

L

N

Y/G

P2-2

Fuse

20

Amp

P5-5

P6-2

P6-1

HL

HF

P6-3

P6-5

Mot

orC

apac

itor

R

Y

Whi

teTa

b

Gol

den

TabC

LTT

Mon

itor

Inte

rlock

Switc

h

W

BUBK

P5-2

P5-1

Prim

ary

Inte

rlock

Switc

h

Sec

onda

ry In

terlo

ckS

witc

hW

BU

Mag

netr

on T

herm

osta

t

Red

Tub

e

Blac

k T

ube

W

R

Mag

netro

n

H.V

.C

apac

itor H

.V.

Dio

de

FAF

R (HV)

HF NTC

MW

Rel

ay49

03P7

L.V.

Tran

sfor

mer

PCBA

33K

21

Fuse

P4-2

BR

HF

Rel

ay49

02 HF

Rel

ay49

05

HL

Rel

ay49

11

HL

Rel

ay49

12

CL

Rel

ay49

01

Dw

g. N

o.:

MU

-097

-T - R

ev. C

Con

ditio

n: D

oor

Ope

n.Sy

mbo

l N

otes

:BK

W

ire C

olor

P6-1

Pin

No.

1C

onne

ctor

Nam

e

Y/G

H.V

.Tr

ansf

orm

erL-

INL-

OU

T

N-IN

N-O

UT

P2/

P3/

P4/

P5/

P6/

P7:

Con

nect

ors

W

RHF

Y

BK

BU

Hoo

d Fa

n M

otor

CL

HL

Cav

ity L

ight

Turn

tabl

e M

otor

Hoo

d (C

ookt

op)

Ligh

tTT

BK

: B

U:

R:

BR

:O

R:

W:

G:

Y:

GY

:

Bla

ckB

lue

Red

Bro

wn

Ora

nge

Whi

teG

reen

Yel

low

Gra

y

BK

BKW

W

BR

BKW

R

W R

R

Y

Y

P4-1

P2-4BU

GY

OR

G

P4-3

P2-1

P3-2

P3-1

W BK

P2-3

Page 3: PRECAUTIONS TO BE OBSERVED BEFORE AND DURING … · 2016. 7. 5. · 4901 TT L.V. BR Transformer H.V. Transformer BU Cavity Light CL P5-2 R GY W BK Filter Board BU OR P5-4 HF Relay

3

Parts Layout (not to scale)

(+) Continuity (-) No ContinuityNOTE: These diagrams are not intended to show a complete circuit; they represent the position of switches during “DOOR OPEN” or “DOOR CLOSED” (continuity checks only).

Door Closed Door Open

A. Hood exhaust fan motor B. Motor capacitor C. H.V. capacitor D. Magnetron E. Magnetron thermostat—opens at

257ºF (125ºC), closes at 185ºF (85ºC)F. Cavity thermostat 2—opens at 221ºF

(105ºC), closes at -31ºF (-35ºC)

G. Cavity thermostat 1—opens at 221ºF (105ºC), closes at -31ºF (-35ºC)

H. NTC thermistor I. H.V. transformer J. H.V. diode K Electronic controlL. Touch panel

M. Secondary interlock switch

N. Monitor interlock switchO. Primary interlock switch P. Light holders Q. Hood (cooktop) light R. Turntable motor S. Cavity light T. Line fuse (20 amp) U. AC filter board

Primary, Secondary, and Monitor Interlock Switch Checkout Procedures

Switch Check By Door Open Door Closed

PrimaryInterlock

1. Unplug microwave oven or disconnect power.2. Disconnect the wires at the Primary Interlock Switch.3. Check from the common terminal (black/brown wires) to the normally open

terminal (black/white wires).

- +

1. Unplug microwave oven or disconnect power.2. Disconnect the wires at the Primary Interlock Switch.3. Check from the common terminal (black/brown wires) to the normally closed

terminal (orange wire).

+ -

Secondary Interlock

1. Unplug microwave oven or disconnect power.2. Disconnect the wires at the Secondary Interlock Switch.3. Check from the common terminal (blue/white wires) to the normally open

terminal (blue/blue wires).

- +

Monitor Interlock

1. Unplug microwave oven or disconnect power.2. Disconnect the wires at the Monitor Interlock Switch.3. Check from the common terminal (white wire) to the normally closed terminal

(blue/white wires).

+ -

A

BC D

E

F

G

IJ

H

U

KL

MNO

T

Q

P

P

3551

3551

P5 P5

R

S

V052

ESUF

A02

L NI-

LTUO-

NTUO-

N NI-

MonitorInterlockSwitch

SecondaryInterlockSwitch

PrimaryInterlockSwitch

(NC) (NO)(NO) (NC) (NO)

L N

MonitorInterlockSwitch

SecondaryInterlockSwitch

PrimaryInterlockSwitch

(NC) (NO)(NO) (NC) (NO)

L N

Page 4: PRECAUTIONS TO BE OBSERVED BEFORE AND DURING … · 2016. 7. 5. · 4901 TT L.V. BR Transformer H.V. Transformer BU Cavity Light CL P5-2 R GY W BK Filter Board BU OR P5-4 HF Relay

4

TROUBLESHOOTINGDo not continue with the diagnostics of appliance if the household fuse is blown, a circuit breaker is tripped or if there is less than 120-volt power supply at the wall outlet.Complete the following steps before checking microwave oven circuitry:1. Unplug microwave oven or disconnect power.2. Discharge high-voltage capacitor and disconnect white wire

from power transformer.

3. Check for loose wiring or incorrect wiring within microwave oven.

4. All testing must be done with an ohmmeter having a sensitivity of 20,000 ohms per volt DC or greater, and powered by at least a 9-volt battery.

5. All operational checks using microwave energy must be done with the microwave oven loaded with a minimum of 8 oz (250 mL) of water in a microwave-safe container.

Microwave Cooking

Hood Exhaust Fan on High Automatically

TurntableMotor

BU

24903BK

1 BR W WBU

SecondaryInterlockSwitch

N

MagnetronThermostat Cavity

Thermostat 1

PrimaryInterlockSwitch

Electronic Control

MWRelay

G

W

P5-1

CL Relay 4901

TT

L.V.TransformerBR

H.V.Transformer

BU

CavityLight

CL

P5-2BUR

GY

W

BK

Filte

rB

oard

BU

OR

P5-4

HF Relay 4902

BK

BUH FWW

BU

BK

Motor Capacitor

Y

R

Y

R

P6-1

P6-5

HF Relay 4905

BK

P2-4

P3-2

BU

P4-3

P2-3

P4-1

P4-2

P2-1L

BK BK

CavityThermostat 2

Fuse20Amp

Filter Board

W

N

CavityThermostat 1

Electronic Control

G

W

L.V. TransformerBR BU

BK

BU

W

Filte

rB

oard

BUP5-4

HFHF Relay

4902BU

BK

MotorCapacitor

Y

R

Y

R

P6-1

P6-5

HF Relay4905

P3-2

P2-3

HF NTC

P7

BU

P4-1BKL

BK BK

CavityThermostat 2

Fuse20Amp

Filter Board

Page 5: PRECAUTIONS TO BE OBSERVED BEFORE AND DURING … · 2016. 7. 5. · 4901 TT L.V. BR Transformer H.V. Transformer BU Cavity Light CL P5-2 R GY W BK Filter Board BU OR P5-4 HF Relay

5

Hood Exhaust Fan on Low Speed

Hood Exhaust Fan on High Manually

Microwave Oven Plugged In—Time of Day Displayed

W

N

CavityThermostat 1

Electronic Control

G

W

L.V. TransformerBR BU

BU

W

Filte

rB

oard

BUP5-4

HFHF Relay

4902

WW

BU

MotorCapacitor

Y

R

Y

R

P6-2

P6-5

HF Relay4905

P3-2

P2-4

BU

P4-1BKL

BK BK

CavityThermostat 2

Fuse20Amp

Filter Board

W

N

CavityThermostat 1

Electronic Control

G

W

L.V. TransformerBR BU

BK

BU

W

Filte

rB

oard

BUP5-4

H FHF Relay

4902BU

BK

MotorCapacitor

Y

R

Y

R

P6-1

P6-5

HF Relay4905 P2-3

P3-2BU

P4-1BKL

BK BK

CavityThermostat 2

Fuse20Amp

Filter Board

BUN

Electronic Control

GBR W

CavityThermostat 1

W L.V. Transformer BU

FilterBoardP5-4

P3-2P4-1BKL

BK BK

CavityThermostat 2

Fuse20Amp

Filter Board

Page 6: PRECAUTIONS TO BE OBSERVED BEFORE AND DURING … · 2016. 7. 5. · 4901 TT L.V. BR Transformer H.V. Transformer BU Cavity Light CL P5-2 R GY W BK Filter Board BU OR P5-4 HF Relay

6

Door Open—Oven Cavity Light Is On

Cooktop Light on High

Cooktop Light on Low (Night Light)

Electronic Control

G BU W

CavityThermostat 1

L.V. TransformerBR

Cavity Light

CL

CL Relay4901 GYPrimary

SwitchInterlock

OR

NWBU

FilterBoardP5-4

W

P3-2

P4-3 BU

P4-1

P2-1BK

L

BK BK

CavityThermostat 2

Fuse20Amp

Filter Board

Electronic Control

G BU

CavityThermostat 1

L.V. Transformer

HL4911

Y

HL Relay

W

P5-4

P5-5

Hood (Cooktop) Light

BRN

WBU

FilterBoard

W

R

P3-2

P2-2

P4-1BKL

BK BK

CavityThermostat 2

Fuse20Amp

Filter Board

Electronic Control

G BU

CavityThermostat 1

L.V. Transformer

HLY

HL Relay4912

Diode6101

W

R

P5-4

P5-5

Hood(Cooktop) Light

BRN

WBU

FilterBoard

W

P2-2

P3-2P4-1BKL

BK BK

CavityThermostat 2

Fuse20Amp

Filter Board

Page 7: PRECAUTIONS TO BE OBSERVED BEFORE AND DURING … · 2016. 7. 5. · 4901 TT L.V. BR Transformer H.V. Transformer BU Cavity Light CL P5-2 R GY W BK Filter Board BU OR P5-4 HF Relay

7

Touch Panel

Touch Panel and Electronic Control Test

The microwave hood combination is provided with a self-diagnostic routine that can be accessed through the touch keypad.

To initiate this routine:1. Press and hold the OFF/CANCEL button while opening the

door. 2. While still holding the OFF/CANCEL button, unplug the

microwave oven for 2 seconds, then plug it back in.

All VFD segments will be lit to indicate the test mode has been entered.

3. Release the OFF/CANCEL button and close the door. NOTE: If the OFF/CANCEL button is pressed during this diagnostic routine, you will exit the test mode.

Key Tables for Test Mode

Key Name Function Display Buzzer

Start/Enter - Key 1 1 beep

Light - Key 3 1 beep

Vent - Key 4 1 beep

Clock - Key 6 1 beep

Kitchen Timer - Key 7 1 beep

Add 30 Sec - Key 9 1 beep

Cook Time - Key 10 1 beep

Cook Power - Key 11 1 beep

Cook - Key 13 1 beep

Reheat - Key 14 1 beep

Defrost - Key 15 1 beep

Popcorn - Key 18 1 beep

Baked Potato - Key 19 1 beep

Pizza Slice - Key 20 1 beep

Options - Key 25 1 beep

Key Name Function Display Buzzer

0 - Key 32 1 beep

1 Cavity Light On—Relay 4901

Key 33 1 beep

2 Cooktop Light On (High)—Relay 4911

Key 34 1 beep

3 Microwave Oven On for 10 Seconds—Relay 4903

Key 35 1 beep

4 Hood Thermistor “XXX” 1 beep

5 - Key 37 1 beep

6 Cavity Light & Turntable On—Relay 4901

Key 38 1 beep

7 - Key 39 1 beep

8 Cooktop Light On (Night)— Relay 4912

Key 40 1 beep

9 HF On (High Speed)— Relay 4902 & Relay 4905

Key 41 1 beep

Off/Cancel Exit Test Mode to Standby

- 1 beep

Page 8: PRECAUTIONS TO BE OBSERVED BEFORE AND DURING … · 2016. 7. 5. · 4901 TT L.V. BR Transformer H.V. Transformer BU Cavity Light CL P5-2 R GY W BK Filter Board BU OR P5-4 HF Relay

8

Microwave Oven Power Output Test1. Place 8 oz (250 mL) of lukewarm water in the center of the

microwave oven.2. Operate on HIGH power level for 2 minutes. Water should be

hot.

NOTE: If the water takes longer than 2 minutes to heat, this may indicate either the operating voltage is lower than 110 volts or there is a problem with the microwave oven.

Failure Codes IndicationsNOTE: Many of the problems listed in the chart below may be solved by power cycling: Unplug microwave oven or disconnect power. After 1 minute, plug in microwave oven or reconnect power.

Display Likely Failure Condition Recommended Repair Procedure

Flashing colon “:”

Power failure After a power failure, the colon “:” will be flashing. Press any key to end this indication. The colon will then be steady when in standby.

F2 Touch panel failure 1. Unplug microwave oven or disconnect power.2. Replace touch panel. 3. Replace all parts and panels before operating.4. Plug in microwave oven or reconnect power.5. If problem persists, unplug microwave oven or disconnect power.6. Replace electronic control.7. Replace all parts and panels before operating.8. Plug in microwave oven or reconnect power.

F6 MW relay 1. Unplug microwave oven or disconnect power.2. Check wiring to Relay 4903.3. Check to see if the Relay 4903 contacts (on the relay electronic control) have welded

closed. If the relay contacts have welded closed, proceed to Step 7.4. Replace all parts and panels before operating.5. Plug in microwave oven or reconnect power.6. If problem persists, unplug microwave oven or disconnect power.7. Replace electronic control.8. Replace all parts and panels before operating.9. Plug in microwave oven or reconnect power.

Page 9: PRECAUTIONS TO BE OBSERVED BEFORE AND DURING … · 2016. 7. 5. · 4901 TT L.V. BR Transformer H.V. Transformer BU Cavity Light CL P5-2 R GY W BK Filter Board BU OR P5-4 HF Relay

9

Component Tests

IMPORTANT:

■ Unplug microwave oven or disconnect power.

■ Discharge the high-voltage capacitor and remove the lead wires from the primary winding of the high-voltage transformer before conducting any of the following tests.

■ Remove the lead wires from the related component before conducting any of the following tests.

■ All operational checks using microwave energy must be done with the microwave oven loaded with a minimum of 8 oz (250 mL) of water in a microwave-safe container.

■ Conduct a microwave energy test after performing any tests or repairs to the microwave oven.

■ Check that all wire leads are in the correct positions before operating the microwave oven.

■ Grasp wire connectors when removing the wire leads from microwave oven parts.

■ All testing must be done with an ohmmeter having a sensitivity of 20,000 ohms per volt DC or greater, and powered by at least a 9-volt battery.

Components Test/Results

H.V. Transformer 1. Unplug microwave oven or disconnect power.2. Remove wire leads.3. Measure resistance:

■ Primary winding: Less than 0.5 ohm (approximate)

■ Secondary winding: 80 ohms (approximate)

■ Filament winding: 0 ohms

■ Primary winding to grounding: Normal: Infinite

■ Filament winding to grounding: Normal: Infinite

Magnetron 1. Unplug microwave oven or disconnect power.2. Remove wire leads. 3. Measure resistance:

■ Filament terminal: Normal: Less than 1 ohm

■ Filament to chassis: Normal: Infinite

H.V. Capacitor 1. Unplug microwave oven or disconnect power.2. Remove wire leads.3. Measure resistance:

■ Terminal to terminal: Normal: Momentarily indicates several ohms, gradually returns to Infinite

■ Terminal to case: Normal: Infinite

H.V. Diode NOTE: Some inexpensive meters may indicate infinite resistance in both directions.1. Unplug microwave oven or disconnect power.2. Measure resistance:

■ Forward: Normal: Continuity; Abnormal: Infinite

■ Reverse: Normal: Infinite; Abnormal: Continuity

Primary

Secondary (white wire - ground to transformer case)

Filament(orange/red wires)

Page 10: PRECAUTIONS TO BE OBSERVED BEFORE AND DURING … · 2016. 7. 5. · 4901 TT L.V. BR Transformer H.V. Transformer BU Cavity Light CL P5-2 R GY W BK Filter Board BU OR P5-4 HF Relay

10

Turntable Motor 1. Unplug microwave oven or disconnect power.2. Remove wire leads.3. Measure resistance:

■ Normal: 2.7k to 3.8k ohms (approximate)

■ Abnormal: Infinite

Motor Capacitor 1. Unplug microwave oven or disconnect power.2. Remove wire leads.3. Measure resistance:

■ Normal: Momentarily 0 ohms, then goes to infinite

■ Abnormal: Infinite

Hood Exhaust Fan Motor 1. Unplug microwave oven or disconnect power.2. Remove wire leads.3. Measure resistance:

■ High Speed—Normal: Red (R) and Blue (BU) wires: 100 to 200 ohms (approximate); Blue (BU) and Black (BK) wires: 40 to 100 ohms (approximate); Abnormal: Infinite

■ Low Speed—Normal: Red (R) and Blue (BU) wires: 100 to 200 ohms (approximate); Blue (BU) and White (W) wires: 80 to 150 ohms (approximate); Abnormal: Infinite

NTC Thermistor 1. If “NTC SHORT, CALL FOR SERVICE” or “NTC OPEN, CALL FOR SERVICE” scrolls on display, unplug microwave oven or disconnect power.

2. Measure hood thermistor:■ Normal: 10k ohms +/- 5% at 77ºF (25ºC)

■ Abnormal: Infinite/continuity

AC Line Filter Board 1. Unplug microwave oven or disconnect power.2. Remove wire leads.3. Measure resistance:

■ Normal: L-IN to L-OUT (coil): Less than 1 ohm; N-IN to N-OUT (coil): Less than 1 ohm

■ Abnormal: Infinite

Thermostats NOTE: Refer to “Parts Layout” for opening and closing temperatures.1. Unplug microwave oven or disconnect power.2. Remove wire leads.3. Measure continuity:

■ Normal: Continuity

■ Abnormal: Infinite

Components Test/Results

3551

P5

V0

52

ES

UF

A0

2

L NI-

L TUO-

N TUO-N NI-

Cavity ThermostatsMagnetron Thermostat

Page 11: PRECAUTIONS TO BE OBSERVED BEFORE AND DURING … · 2016. 7. 5. · 4901 TT L.V. BR Transformer H.V. Transformer BU Cavity Light CL P5-2 R GY W BK Filter Board BU OR P5-4 HF Relay

11

Fiche technique À conserver

PRÉCAUTIONS À PRENDRE AVANT ET PENDANT LES RÉPARATIONS POUR ÉVITER UNE EXPOSITION EXCESSIVE À L'ÉNERGIE DES MICRO-ONDES

a. Ne pas faire fonctionner le four lorsque la porte est ouverte.b. Sur chaque four, avant d'alimenter le magnétron ou une

autre source de micro-ondes, exécuter les contrôles de sécurité suivants et effectuer les réparations nécessaires :

1. Système d’interverrouillage—fonctionnement2. Porte—fermeture correcte3. Joint et surfaces de scellement (formation d’arcs, usure et

autres détériorations)4. Charnières et loquets—détérioration ou mauvais

ajustements (desserrage)5. Indices de détérioration par chute ou d’emploi abusif

c. Avant de mettre le four à micro-ondes sous tension pour des opérations de test ou d’inspection dans les compartiments de génération de micro-ondes, contrôler le magnétron, le guide d'ondes/canal de transmission et la cavité —contrôler l’alignement correct, l’intégrité, les connexions.

d. Avant de remettre le four à son propriétaire, toute défectuosité ou mauvais ajustement de composant affectant l’interverrouillage, le moniteur, le joint de porte et les systèmes de génération/transmission de micro-ondes, devra être éliminé par réparation/remplacement/réglage conformément aux procédures décrites dans ce manuel.

e. Avant de remettre l’appareil à son propriétaire, on doit effectuer un test de mesure du taux de fuite de micro-ondes, pour vérifier que l’appareil satisfait aux critères des normes CSA.

f. Ne pas tenter de faire fonctionner le four si la vitre de la porte est brisée.

AVERTISSEMENT

Risque de choc électrique

Déconnecter la source de courant électrique avant l'entretien.

Replacer pièces et panneaux avant de faire la remise en marche.

Le non-respect de ces instructions peut causer un décès ou un choc électrique.

W10249266A / 461965199723 À L’USAGE DU TECHNICIEN SEULEMENT

Page 12: PRECAUTIONS TO BE OBSERVED BEFORE AND DURING … · 2016. 7. 5. · 4901 TT L.V. BR Transformer H.V. Transformer BU Cavity Light CL P5-2 R GY W BK Filter Board BU OR P5-4 HF Relay

12

SCHÉMAS DE CÂBLAGESchéma des circuits

Cy

Cy

Cx

R

L

120 V / CA/60 HzCordon

d'alimentation

Ther

mos

tat 1

- ca

vité

du

four

BU

Term

inal

blan

c

Term

inal

doré

Dio

de 6

101

Ther

mos

tat

2 -

cavi

té d

u fo

ur

P5-4

Car

te

de fi

ltrag

eLN

N

VE

L

N

JA/VE

P2-2

Fusi

ble

20 A

P5-5

P6-2

P6-1

HL

HF

P6-3

P6-5

Con

dens

ateu

rdu

mot

eur

R

JA

CL

TT

Contacteurinterverrouillage

de contrôle BL

BUN

P5-2

P5-1

Contacteurinterverrouillage

primaireCon

tact

eur

inte

rver

roui

llage

sec

onda

ireBL

BU

Ther

mos

tat m

agné

tron

Tube

roug

e

Tube

noi

r

BL

R

Mag

nétro

n

Con

dens

ateu

rha

ute

tens

ion

Dio

deha

ute

tens

ionFA

F

R (HV)

HF NTC

Rel

ais -

mic

ro-o

ndes

4903

P7

Tran

sfor

mat

eur

bass

e te

nsio

nPC

BA

33K

21

Fusible

P4-2

MAR

Rel

ais

HF

4902

Rel

ais

HF

4905

Rel

ais

HL

4911

Rel

ais

HL

4912

Rel

ais

CL

4901

Des

sin

Nº :

MU

-097

-T -

Rév

. CS

ituat

ion

: Por

te o

uver

te.

Sym

bol e

s :

N

C

oule

ur d

u f

il

P6-

1

B

roch

e N

º 1

Nom

du

conn

ecte

ur

JA/VE

Tran

sfor

mat

eur

haut

e te

nsio

nE

ntré

eph

ase

Sor

tieph

ase

Ent

rée

neut

reS

ortie

neut

re

BL

RHF

JA

N BU

Mot

eur

-ve

ntila

teur

hot

teC

LH

LLa

mpe

- c

avité

du

four

Mot

eur

- pl

atea

u ro

tatif

Lam

pe -

hot

te(t

able

de

cuis

son)

TT

N :

BU

:R

:M

AR

:O

R :

BL

:V

E :

JA :

Noi

rB

leu

Rou

geM

arro

nO

rang

eB

lanc

Ver

tJa

une

N

NBL

BL

MAR

NBL

R

BL R

R

JA

JA

P4-1

P2-4BU

GRIS

OR

VE

P4-3

P2-1

P3-2

P3-1

BL N

P2-3

P2/

P3/

P4/

P5/

P6/

P7

: Con

nect

eurs

Term

inal

doré

Term

inal

blan

c

Page 13: PRECAUTIONS TO BE OBSERVED BEFORE AND DURING … · 2016. 7. 5. · 4901 TT L.V. BR Transformer H.V. Transformer BU Cavity Light CL P5-2 R GY W BK Filter Board BU OR P5-4 HF Relay

13

Répartition des composants (Pas à l’échelle)

(+) Continuité (-) Circuit ouvertREMARQUE : Ces schémas ne présentent pas un circuit complet; ils représentent la position des contacteurs pour PORTE OUVERTE ou PORTE FERMÉE (pour contrôle de continuité seulement).

Porte fermée Porte ouverte

A. Ensemble moteur—ventilateur—hotte B. Condensateur du moteur C. Condensateur haute tension D. Magnétron E. Thermostat—magnétron—ouvert à 257ºF

(125ºC), fermé à 185ºF (85ºC)F. Thermostat 2—cavité du four—ouvert à

221ºF (105ºC), fermé à -31ºF (-35ºC)

G. Thermostat 1—cavité du four—ouvert à 221ºF (105ºC), fermé à -31ºF (-35ºC)

H. NTC ThermistorI. Transformateur haute tension J. Diode haute tension K. Carte des circuits de commande L. Tableau de commande tactile

M. Contacteur interverrouillage secondaire

N. Contacteur interverrouillage de contrôleO. Contacteur interverrouillage primaireP. Douilles de lampe Q. Lampe de la hotte (table de cuisson) R. Moteur—plateau rotatifS. Lampe—cavité du four T. Fusible (alimentation) (20 A) U. Filtre sur ligne CA

Processus de contrôle des contacteurs d’interverrouillage—primaire, secondaire et contrôle

Contacteur Pour contrôler Porte ouverte Porte fermée

Interverrouillage primaire

1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique.

2. Déconnecter les conducteurs du contacteur d’interverrouillage primaire.3. Vérifier l’alimentation de la borne commune (conducteurs noir/marron) à la

borne normalement ouverte (conducteurs noir/blanc).

- +

1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique.

2. Déconnecter les conducteurs du contacteur d’interverrouillage primaire.3. Vérifier l’alimentation de la borne commune (conducteurs noir/marron) à la

borne normalement fermée (conducteur orange).

+ -

Interverrouillage secondaire

1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique.

2. Déconnecter les conducteurs du contacteur d’interverrouillage secondaire.3. Vérifier l’alimentation de la borne commune (conducteurs bleu/blanc) à la

borne normalement ouverte (conducteurs bleus).

- +

Interverrouillage de contrôle

1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique.

2. Déconnecter les conducteurs du contacteur d’interverrouillage de contrôle.3. Vérifier l’alimentation de la borne commune (conducteur blanc) à la borne

normalement fermée (conducteur bleu/blanc).

+ -

A

BC D

E

F

G

IJ

H

U

KL

MNO

T

Q

P

P

3551

3551

P5 P5

R

S

V052

ESUF

A02

L NI-

LTUO-

NTUO-

N NI-

(NF) (NO)(NO) (NF) (NO)

L NEU

Contacteurinterverrouillage

primaire

Contacteurinterverrouillage

de contrôle

Contacteurinterverrouillage

secondaire

(NF) (NO)(NO) (NF) (NO)L NEU

Contacteurinterverrouillage

primaire

Contacteurinterverrouillage

de contrôle

Contacteurinterverrouillage

secondaire

Page 14: PRECAUTIONS TO BE OBSERVED BEFORE AND DURING … · 2016. 7. 5. · 4901 TT L.V. BR Transformer H.V. Transformer BU Cavity Light CL P5-2 R GY W BK Filter Board BU OR P5-4 HF Relay

14

DÉPANNAGENe pas poursuivre le diagnostic de l’appareil si le fusible est grillé, si un disjoncteur est ouvert, ou si la tension d’alimentation de la prise murale est inférieure à 120 volts.Exécuter les opérations suivantes avant de contrôler les circuits du four à micro-ondes :1. Débrancher le four à micro-ondes ou déconnecter la source

de courant électrique.2. Décharger le condensateur haute tension, et déconnecter le

fil blanc du transformateur d’alimentation.

3. Rechercher des fils du four à micro-ondes mal connectés ou déconnectés.

4. Exécuter tous les contrôles avec un ohmmètre à résistance interne de 20 000 ohms par volt CC ou plus, alimenté par une pile d’au moins 9 volts.

5. Pour tous les contrôles impliquant la génération de micro-ondes, on doit placer à l’intérieur du four au moins 8 oz (250 mL) d’eau dans un récipient compatible avec les micro-ondes.

Cuisson aux micro-ondes

Ventilateur—mise en marche automatique à vitesse élevée

N

Moteur -plateau rotatif

BU

P2-1

24903N

1 MAR BL BLBU

Contacteurinterverrouillagesecondaire

N

magnétronThermostat

Thermostat 1 -cavité du four

Fusible20A

Contacteur

primaireinterverrouillage

Car te des circuits de commande

Relais -micro-ondes

VE

BL

P5-1

Relais CL4901

TT

Transformateurbasse tensionMAR

Transformeurhaute tension

BU

Lampe -cavité

du fourCL

P5-2BUR

GRIS

BL

NN

Carte de filtrage

Car

te d

e fi

ltrag

e

BU

OR

P5-4

Relais HF4902

N

BUH FBLBL

BU

N

Condensateur du moteur

JA

R

JA

R

P6-1

P6-5

Relais HF4905

N

P4-3

P2-4

P2-3

P3-2

BU

cavité du fourThermostat 2 -

P4-2

P4-1

P

BL

N

cavité du fourThermostat 1 -

Car te de circuits de commande

VE

BL

Transformateurbasse tensionMAR BU

N

BU

BL

Car

te d

e fi

ltrag

e

BUP5-4

HFRelais HF

4902BU

N

Condensateur du moteur

JA

R

JA

R

P6-1

P6-5

Relais HF4905

P3-2

P2-3

Thermistancede la hotte

BU

P7

P4-1N

Fusible20A

NN

Carte de filtrage

cavité du fourThermostat 2 -

P

Page 15: PRECAUTIONS TO BE OBSERVED BEFORE AND DURING … · 2016. 7. 5. · 4901 TT L.V. BR Transformer H.V. Transformer BU Cavity Light CL P5-2 R GY W BK Filter Board BU OR P5-4 HF Relay

15

Ventilateur—mise en marche à basse vitesse

Ventilateur—mise en marche manuelle à vitesse élevée

Four à micro-ondes branché—heure affichée

BL

N

Thermostat 1 - cavité du four

Carte de circuits de commande

VE

BL

Transformateurbasse tensionMAR BU

BU

BL

Car

te d

e fi

ltrag

e

BUP5-4

HFRelais HF

4902

BLBL

BU

Condensateur du moteur

JA

R

JA

R

P6-2

P6-5

Relais HF4905

P3-2

P2-4

BUP4-1N

Fusible20A

NN

Carte de filtrage

cavité du fourThermostat 2 -

P

BL

N

Carte de circuits de commande

VE

BL

Transformateurbasse tensionMAR BU

N

BU

BL

Car

te d

e fi

ltrag

e

BUP5-4

H FRelais HF

4902BU

N

Condensateur du moteur

JA

R

JA

R

P6-1

P6-5

Relais HF4905

P2-3

P3-2BU

Thermostat 1 - cavité du four

P4-1N

Fusible20A

NN

Carte de filtrage

cavité du fourThermostat 2 -

P

BUN

Carte de circuits de commande

VEMAR BL

Thermostat 1-cavité du four

BLTransformateurbasse tension BU

Carte de filtrageP5-4

P3-2P4-1N

Fusible20A

NN

Carte de filtrage

cavité du fourThermostat 2 -

P

Page 16: PRECAUTIONS TO BE OBSERVED BEFORE AND DURING … · 2016. 7. 5. · 4901 TT L.V. BR Transformer H.V. Transformer BU Cavity Light CL P5-2 R GY W BK Filter Board BU OR P5-4 HF Relay

16

Porte ouverte—lampe cavité du four allumée

Lampe table de cuisson—éclairage fort

Lampe table de cuisson—éclairage faible (veilleuse)

Carte de circuits de commande

VE BU BL

Transformateurbasse tensionMAR

Lampe - cavitédu four

CL

Relais CL4901 GRIS

OR

NBLBU

Carte de filtrageP5-4

BLP4-3Contacteur

interverrouillageprimaire

BU

Thermostat 1 - cavité du four

P4-1

P2-1

P3-2

N

Fusible20A

NN

Carte de filtrage

cavité du fourThermostat 2 -

P

Carte de circuits de commande

VE BU

Thermostat 1-cavité du four

Transformateurbasse tension

HL4911 JA

Relais HL

BL

P5-4

P5-5

MARN

BLBU

Carte defiltrage

BL

R

P3-2

P2-2

Lampe - hotte(table de cuisson)

P4-1N

Fusible20A

NN

Carte de filtrage

cavité du fourThermostat 2 -

P

Carte de circuits de commande

VE BU

Thermostat 1-cavité du four

Transformateurbasse tension

HLJA

Relais HL4912

Diode6101

BL

R

P5-4

P5-5 Lampe - hotte(table de cuisson)

MARN

BLBUCarte de filtrage

BL

P2-2

P3-2P4-1N

Fusible20A

NN

Carte de filtrage

cavité du fourThermostat 2 -

P

Page 17: PRECAUTIONS TO BE OBSERVED BEFORE AND DURING … · 2016. 7. 5. · 4901 TT L.V. BR Transformer H.V. Transformer BU Cavity Light CL P5-2 R GY W BK Filter Board BU OR P5-4 HF Relay

17

Tableau de commande tactile

Test du tableau de commande tactile et de la carte des circuits de commande

L’ensemble four à micro-ondes/hotte comporte un système d’autodiagnostic commandé par l’intermédiaire du clavier tactile.

Pour exécuter le processus :1. Appuyer sur la touche OFF/CANCEL (arrêt/annulation)

lorsque la porte est ouverte. 2. Tout en appuyant sur la touche OFF/CANCEL, débrancher

l’appareil pendant deux secondes, puis rebrancher l’appareil.

Tous les segments VFD seront allumés pour indiquer que le mode test est en cours.

3. Lâcher la touche OFF/CANCEL et fermer la porte. REMARQUE : Si on appuie sur la touche OFF/CANCEL pendant ce diagnostic, le mode de test est annulé.

Tableau des touches pour le mode de test

Touche Fonction Affichage Avertisseur

Start (mise en marche)/Enter

- Key 1 1 signal sonore

Light (lampe) - Key 3 1 signal sonore

Vent (ventilateur) - Key 4 1 signal sonore

Clock (horloge) - Key 6 1 signal sonore

Kitchen Timer (minuterie) - Key 7 1 signal sonore

Add 30 Sec (ajouter 30 secondes)

- Key 9 1 signal sonore

Cook Time (temps de cuisson)

- Key 10 1 signal sonore

Cook Power (puissance de cuisson)

- Key 11 1 signal sonore

Cook (cuisson) - Key 13 1 signal sonore

Reheat (réchauffage) - Key 14 1 signal sonore

Defrost (décongélation) - Key 15 1 signal sonore

Popcorn (maïs éclaté) - Key 18 1 signal sonore

Baked Potato (pommes de terre au four)

- Key 19 1 signal sonore

Pizza Slice (part de pizza) - Key 20 1 signal sonore

Touche Fonction Affichage Avertisseur

Options - Key 25 1 signal sonore

0 - Key 32 1 signal sonore

1 Relais 4901— lampe cavité allumée

Key 33 1 signal sonore

2 Relais 4911— lampe table de cuisson allumée (éclairage fort)

Key 34 1 signal sonore

3 Relais 4903—four à micro-ondes allumé pendant 10 sec.

Key 35 1 signal sonore

4 Thermistance de la hotte

“XXX” 1 signal sonore

5 - Key 37 1 signal sonore

6 Relais 4901— lampe cavité du four et plateau rotatif allumés

Key 38 1 signal sonore

7 - Key 39 1 signal sonore

8 Relais 4912— lampe table de cuisson allumée (veilleuse)

Key 40 1 signal sonore

9 Relais 4902 et 4905—ventilateur en marche (vitesse élevée)

Key 41 1 signal sonore

Off/Cancel (arrêt/annulation)

Quitter le mode de test - 1 signal sonore

Page 18: PRECAUTIONS TO BE OBSERVED BEFORE AND DURING … · 2016. 7. 5. · 4901 TT L.V. BR Transformer H.V. Transformer BU Cavity Light CL P5-2 R GY W BK Filter Board BU OR P5-4 HF Relay

18

Test de la puissance du four à micro-ondes1. Placer un récipient d'eau tiède (8 oz [250 mL]) au centre du

four.2. Faire fonctionner le four au niveau de puissance maximum

(HIGH) pendant 2 minutes. L'eau devrait être chaude.

REMARQUE : Si plus de 2 minutes sont nécessaires pour chauffer l'eau, il se peut que le voltage soit inférieur à 110 volts ou qu'il y ait un problème avec le four à micro-ondes.

Identification des codes de défaillanceREMARQUE : De nombreux problèmes reportés dans le tableau ci-dessous peuvent être résolus en arrêtant et relançant l'alimentation électrique : débrancher le four à micro-ondes ou déconnecter la source de courant électrique. Après une minute, brancher le four à micro-ondes ou reconnecter la source de courant électrique.

Affichage Défaillance probable Méthode de réparation recommandée

Clignotement “:” Panned’électricité

Après une panne d’électricité, on observe le clignotement du “:”. Appuyer sur une touche quelconque pour mettre fin au clignotement. L’affichage devient stable (mode d’attente).

F2 Défaillance—tableau de commande tactile

1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique.2. Remplacer le tableau de commande tactile. 3. Replacer pièces et panneaux avant de faire la remise en marche.4. Brancher le four à micro-ondes ou reconnecter la source de courant électrique.5. Si le problème persiste, débrancher le four à micro-ondes ou déconnecter la source de

courant électrique.6. Remplacer la carte des circuits de commande.7. Replacer pièces et panneaux avant de faire la remise en marche.8. Brancher le four à micro-ondes ou reconnecter la source de courant électrique.

F6 Défaillance—relais micro-ondes

1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique.2. Contrôler les connexions du relais 4903.3. Vérifier si les contacts du relais 4903 (sur le module de commande électronique du

relais) se sont soudés en position fermée. Si les contacts sont soudés en position fermée, passer à l’étape 7.

4. Replacer pièces et panneaux avant de faire la remise en marche.5. Brancher le four à micro-ondes ou reconnecter la source de courant électrique. 6. Si le problème persiste, débrancher le four à micro-ondes ou déconnecter la source de

courant électrique.7. Remplacer la carte des circuits de commande.8. Replacer pièces et panneaux avant de faire la remise en marche.9. Brancher le four à micro-ondes ou reconnecter la source de courant électrique.

Page 19: PRECAUTIONS TO BE OBSERVED BEFORE AND DURING … · 2016. 7. 5. · 4901 TT L.V. BR Transformer H.V. Transformer BU Cavity Light CL P5-2 R GY W BK Filter Board BU OR P5-4 HF Relay

19

Tests des composants

IMPORTANT :

■ Débrancher le four à micro-ondes ou déconnecter la source de courant électrique.

■ Décharger le condensateur haute tension et débrancher les conducteurs du bobinage primaire du transformateur haute tension avant d’effectuer l’un des tests suivants.

■ Avant d’exécuter les tests suivants, débrancher les fils de connexion du composant.

■ Pour tous les contrôles impliquant la génération de micro-ondes, on doit placer à l’intérieur du four au moins 8 oz (250 mL) d’eau dans un récipient compatible avec les micro-ondes.

■ Après tout test ou réparation du four à micro-ondes, exécuter un test de contrôle de l’énergie émise par les micro-ondes.

■ Avant de faire fonctionner le four à micro-ondes, vérifier que tous les fils du câblage sont à la position correcte.

■ Pour débrancher les conducteurs des composants du four à micro-ondes, saisir chaque connecteur.

■ Exécuter tous les contrôles avec un ohmmètre à résistance interne de 20 000 ohms par volt CC ou plus, alimenté par une pile d’au moins 9 volts.

Composants Test/Résultats

Transformateur haute tension 1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique.2. Débrancher les conducteurs.3. Mesurer la résistance :

■ Bobinage primaire : Moins de 0,5 ohm (environ)

■ Bobinage secondaire : 80 ohms (environ)

■ Bobinage filament : 0 ohm

■ Bobinage primaire—masse : Normal : résistance infinie

■ Bobinage filament—masse : Normal : résistance infinie

Magnétron 1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique.2. Débrancher les conducteurs. 3. Mesurer la résistance :

■ Bobinage filament : Normal : Moins de 1 ohm

■ Bobinage filament—châssis : Normal : résistance infinie

Condensateur haute tension 1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique.2. Débrancher les conducteurs.3. Mesurer la résistance :

■ Borne—borne : Normal : indique momentanément une résistance de quelques ohms; retour graduel à résistance infinie

■ Borne—boîtier : Normal : résistance infinie

Bobinage primaire

Bobinage secondaire (conducteursblanc - masse - boîtier du transformateur)

Bobinage filament(conducteursorange/rouge)

Page 20: PRECAUTIONS TO BE OBSERVED BEFORE AND DURING … · 2016. 7. 5. · 4901 TT L.V. BR Transformer H.V. Transformer BU Cavity Light CL P5-2 R GY W BK Filter Board BU OR P5-4 HF Relay

Diode haute tension REMARQUE : Certains instruments de mesure peu coûteux peuvent indiquer une résistance infinie dans les deux directions.1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique.2. Mesurer la résistance :

■ Sens direct : Normal : continuité; Anormal : résistance infinie

■ Sens inverse : Normal : résistance infinie; Anormal : continuité

Moteur—Plateau rotatif 1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique.2. Débrancher les conducteurs.3. Mesurer la résistance :

■ Normal : 2,7 à 3,8k ohms (environ)

■ Anormal : résistance infinie

Condensateur du moteur 1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique.2. Débrancher les conducteurs.3. Mesurer la résistance :

■ Normal : indique momentanément 0 ohm puis retour à résistance infinie.

■ Anormal : résistance infinie

Moteur du ventilateur—hotte 1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique.2. Débrancher les conducteurs.3. Mesurer la résistance :

■ Vitesse haute—Normal : Conducteurs rouge (R) et bleu (BU) : 100 à 200 ohms (environ); Conducteurs bleu (BU) et noir (N) : 40 à 100 ohms (environ); Anormal : résistance infinie

■ Vitesse basse—Normal : Conducteurs rouge (R) et bleu (BU) : 100 à 200 ohms (environ); Conducteurs bleu (BU) et blanc (BL) : 80 à 150 ohms (environ); Anormal : résistance infinie

Thermistance de la hotte 1. Si “NTC SHORT, CALL FOR SERVICE” ou “NTC OPEN, CALL FOR SERVICE” défile sur l'afficheur, débrancher le four à micro-ondes ou déconnecter la source de courant électrique.

2. Mesurer la résistance :■ Normal : 10k ohms +/- 5% à 77ºF (25ºC).

■ Anormal : résistance infinie/continuité.

Carte de filtrage CA 1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique.2. Débrancher les conducteurs.3. Mesurer la résistance :

■ Normal : L-IN à L-OUT (bobine) : moins de 1 ohm; N-IN à N-OUT (bobine) : moins de 1 ohm

■ Anormal : résistance infinie

Thermostats REMARQUE : Pour les températures d’ouverture et de fermeture, voir le schéma de “Répartition des composants”.1. Débrancher le four à micro-ondes ou déconnecter la source de courant électrique.2. Débrancher les conducteurs.3. Mesurer la continuité :

■ Normal : continuité

■ Anormal : résistance infinie

Composants Test/Résultats

3551

P5

V0

52

ES

UF

A0

2

L NI-

L TUO-

N TUO-N NI-

Thermostats - cavitéThermostat - magnétron

W10249266A / 461965199723 © 2010. All rights reserved.Tous droits réservés.

3/10FOR SERVICE TECHNICIAN’S USE ONLY

À L’USAGE DU TECHNICIEN SEULEMENT