pre-tensioned high strength spun concrete piles - · pdf fileclass c (effective prestress =...

2
Pre-tensioned High Strength Spun Concrete Piles ® HBL

Upload: lethuy

Post on 30-Jan-2018

219 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Pre-tensioned High Strength Spun Concrete Piles - · PDF fileClass C (Effective Prestress = 7.0 N/mm2) Abbreviations - IS : Indian Standard Note: The loads represents the structural

Pre-tensioned High Strength Spun Concrete Piles

®

HBL

Page 2: Pre-tensioned High Strength Spun Concrete Piles - · PDF fileClass C (Effective Prestress = 7.0 N/mm2) Abbreviations - IS : Indian Standard Note: The loads represents the structural

2Class C (Effective Prestress = 7.0 N/mm )

Abbreviations - IS : Indian Standard

Note: The loads represents the structural capacities of the piles without considering the soil conditions and slenderness ratio.

Special Features of HBL Piles

Product Attributes:

Spinning Process results in more durable concrete with high resistance to corrosion.

Grade 80 Concrete enables the piles to be driven through hard strata.

Can be manufactured to the lengths & dia as required customer's requirement.

Environmentally friendly installation by hydraulic Hammers.

Precast Spun Pile Deep Foundation is faster, easier & highly cost effective and require much less time.

Welded Joint Detail

Steel band

Butt weld

SeeDetail ‘y’

End Plate

Pre-stressingSteelBar

SteelSpairal

t

10

0m

m t

o 1

50

mm

ST

EE

L S

PIR

AL

AT

PIT

CH

OF

50 m

m

t022

Deatail ‘x’

Corp

Com

m /

Feb.

2017

HBL Power Systems LimitedHBL

®

Reg. Office: No. 8-2-601, Rd. No.10, Banjara Hills, Hyderabad – 500 034, India

Mfg. Unit1: S. No. 583, Laxmapur Road, Alliabad, Shamirpet (Mandal), R. R. Dist., Hyderabad – 500078

Mfg. Unit2: S. No. 123-126, 138 (P) to 144 (P), Kandivalasa, Pusapatirega Mandaa, Vizianagaram Dist., AP

Mfg. Unit3: S. No. 456-458 Kanaparru, Nadendla Mandal, Guntur Dist., Andhra Pradesh – 522549

Mobile Nos.: 98483 08088, 98480 23276, 80969 67933

E-mail: [email protected], [email protected], [email protected], [email protected], Web site: www.hbl.in

Area ofconcrete

2(cm )

Descri

pti

on

OD(mm)

Wallthickness

(mm)

Steel Bars PC wire

(Фmm/Nos)

Effective Pre-stress of concrete

2(N/mm )

NominalWeight(kg/m)

Crack BendingMoment(kNm)

UltimateBendingMoment(kNm)

Design Value of single

pile Strength Vertical Load Bearing (t)

Pre

cast

P

restr

essed

Sp

un

C

on

cre

te

Pil

e

804

1571

80

100

9.0 / 12

9.0 / 24

7.50

7.00

209.00

408.00

67.00

195.00

148.00

365.00

144.00

286.00

Ф 400

Ф 600

2565120 9.0 / 36 7.00 666.00 450.00 810.00 467.00Ф 800

Detail ‘Y’

a=EFFECTIVE THROAT THICKNESSPLUS 2mm CORROSION ALLOWANCE

022

b

t

t

b

WELDED JOINT DETAIL

a

WELDED JOINT DETAIL

Steel Band

Steel Band

‘X’