Goals
• Being skilled to use microscope
• To know some important principle so that student could operate microscope: good in short time.
• Determine alternatif procedure which be wanted
• Making adaptor self and taking photo (optional)
![Page 3: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/3.jpg)
Assignment in Practice Microscope January 2008
1. Mention the parts of a microscope!2. What is the function of those parts?3. How to optimalize the functions?4. What should be done to maximize your RP?5. What is the NA of your microscope?6. And from your right and left hand side microscope? 7. RP of no. 5 and 6: what is better? What is your argument?8. Figure the tissue with low, medium and high power
(magnification of objective 10x, 40x, and 100x)! Write the overall magnification 100x, 400x, 1000x.
9. Report your experiences in using microscope: The steps!10.What is the difference with the steps mention in theory?
![Page 4: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/4.jpg)
Micoscope Figure
• Oculer: 10x, 15x, 20x• Objektive 10x, 40 x, 100x dan NA 0,45,
0,65• Condensor • Light source or mirror• Immersion oil• Magnification• Object glass
![Page 5: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/5.jpg)
![Page 6: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/6.jpg)
Optical Pathways (Magnifying)
![Page 7: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/7.jpg)
Several theory
• Resolving Power
• NA: Numerical Aperture
• Immersion oil
• How to use Condensor
![Page 8: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/8.jpg)
Lens protection and putting slide while
• Bringing microscope
• Cleaning lens
• Focusing small objective power 4x and medium 10x
• Studying slides with high power 40-45x or when using immersion oil
• Rapikan mik setelah selesai !
![Page 9: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/9.jpg)
Identify part of the microscope• Do it several times, think about the
function
![Page 10: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/10.jpg)
![Page 11: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/11.jpg)
Different location of coarse and fine adjustment
![Page 12: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/12.jpg)
Fine ajustment
![Page 13: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/13.jpg)
How to get the best RP from a microscope incl. how and when to
do:
• Cleaning the lenses
• Illuminate the specimen
• Focusing the condenser
• Ajust the diagfragma
• Using immersion
• Setting light intensity
![Page 14: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/14.jpg)
Ocular and objective lens
![Page 15: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/15.jpg)
Magnification & Numeric Aperture
![Page 16: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/16.jpg)
NA = n sin
![Page 17: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/17.jpg)
![Page 18: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/18.jpg)
Resolving Power
Resolution of lens camera is revealed by how many lines per inch (lpi)
![Page 19: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/19.jpg)
Lens resolution• Is the ability of a lens to free shadow from
2 point of thing that is very close.• Resolusion limit = 1.22/D (Resolusion depend
on )
• Daya urai (=Resolving Power;RP;s)= f= 1.22f/D (D=2sin) where f=jarak objek ke lensa objektif
How smaller how smaller RP
How larger D how smallerRP
How bigger how smaller RP
![Page 20: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/20.jpg)
Light source
![Page 21: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/21.jpg)
Long wave length have greater energy
![Page 23: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/23.jpg)
Step in focusing microscope
![Page 24: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/24.jpg)
Step
![Page 25: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/25.jpg)
Step
![Page 26: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/26.jpg)
The best RP visual microscope +- 200 nm
Magnification is not the same with RP
RP microscope mainly depend on obj lens (oculer-max 10x, only magnify image which is found from obj lens-max 100x). Oculer lens didn’t make better the resolusion. Higher magnification with low resolution image blur which is < function
NA= n sin
RP=K.
NA
L objOn the objective was wrote Plan 25/0.45 (Magnification/NA) 160/0.17Tube length in mm
Thickness(in mm) deck glass for which obj lens is corected (dry field)
RP = 0,61 NA
=(0,61)(5,50 x 10-7 m
1,62 x 10 –7 m 200
nmn=1,8 (n immersion oil)
sin 0,90
![Page 27: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/27.jpg)
Large (Fast) NA vs. Small (slow) NA
![Page 28: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/28.jpg)
Thus, NA:
![Page 29: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/29.jpg)
Condensor
• Make better RP with making light lamp 100% of the image-forming kind
• How: with focusing light in the shape of inverse cone, with apex at the specimen and base at the objective
![Page 30: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/30.jpg)
Modern Research Microscope
![Page 31: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/31.jpg)
Tempo, 22 Juni 2003: hal. 16
![Page 32: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/32.jpg)
NA 1.40
![Page 33: Praktikum Mikroskop](https://reader035.vdocuments.us/reader035/viewer/2022081717/54e57ffe4a795943458b48ce/html5/thumbnails/33.jpg)
CCD camera US$3500