PowerShield Battery Monitoring Systems protecting your power supply P r o t e c t i n g y o u r p o w e r s u p p l y 1

Upload: ince

Post on 09-Feb-2016

38 views

Category:

Documents


0 download

DESCRIPTION

PowerShield Battery Monitoring Systems protecting your power supply. PowerShield - Data Center Solutions. Permanent monitoring solution designed for stand-by batteries Complete package including hardware & software Designed to allow IEEE/IEC best practice Fast, accurate, safe & smart - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: PowerShield  Battery Monitoring Systems protecting your power supply

P r o t e c t i n g y o u r p o w e r s u p p l y 1

PowerShield Battery Monitoring Systems

protecting your power supply

Page 2: PowerShield  Battery Monitoring Systems protecting your power supply

Permanent monitoring solution designed for stand-by batteriesComplete package including hardware & softwareDesigned to allow IEEE/IEC best practiceFast, accurate, safe & smartVisibility of your battery assets

Be in control of your batteries.

PowerShield - Data Center Solutions

2P r o t e c t i n g y o u r p o w e r s u p p l y

Page 3: PowerShield  Battery Monitoring Systems protecting your power supply

P r o t e c t i n g y o u r p o w e r s u p p l y 3

Modular layout for safety, efficiency, scalability- Sentinel controller + m-Senzor battery sensors

Up to 1280 blocks / 16 strings per hardware systemStand-alone system operation with on-board memory Can operate without PC or external comms

UL, CUL, CE, C-Tick, FCC, KCC certifiedFast & tidy installationBattery & UPS brand neutral

Maintain manufacturer flexibility & capabilityfor future expansion

In the Battery Room

Page 4: PowerShield  Battery Monitoring Systems protecting your power supply

P r o t e c t i n g y o u r p o w e r s u p p l y 4

In the Battery Room

All parameters sampled continuously & automatically Rapid identification of catastrophic failures

Automatic data logging Allows historic & predictive trending over battery lifetime

Automatic data logging of battery discharge Live assessment of performance Capacity analysis

UPS self-test & intermittent charging compatibility Make best use of UPS functionality

All events and alarms time & date stamped

Page 5: PowerShield  Battery Monitoring Systems protecting your power supply

5

At the Battery

Individual block voltage, sampled simultaneously every 4 seconds

True real-time visibilityIndividual block impedance, sampled daily Sampled only in Float for best comparison & life trending Internal high precision reference for self-calibration

Individual block temperature option Measured at negative terminal as per IEEE recommendations Accurate & block specific thermal runaway detection

P r o t e c t i n g y o u r p o w e r s u p p l y

Page 6: PowerShield  Battery Monitoring Systems protecting your power supply

6

At the Battery

750VDC optical isolation at battery Increased safety of personnel & facility Install flexibility & efficiency – consolidate different block & string voltages [UPS, 48V, genset, emergency lighting] Factory terminated cable sets with no fusing required

Intelligence at the battery Ripple & noise rejection Self-protection Bi-colour LED for fast identification

No more manual battery testing.

P r o t e c t i n g y o u r p o w e r s u p p l y

Page 7: PowerShield  Battery Monitoring Systems protecting your power supply

Raising the Alarm

Alarms for block voltage, impedance & temperature [thermal runaway]; string voltage & current; ambient temperature

All alarm settings user-editable, but with initial defaults offeredSelf-learnt automatic baseline for impedanceAll alarm settings are battery & application specificDetailed, specific alarm information – to individual block levelSystem intelligence applies appropriate limit set for battery state –

Float/Charge/Discharge/IdleNotification of change of string stateAlarms for internal system diagnostics

P r o t e c t i n g y o u r p o w e r s u p p l y 7

Page 8: PowerShield  Battery Monitoring Systems protecting your power supply

P r o t e c t i n g y o u r p o w e r s u p p l y 8

In the Control Room

Alarm & data options for data center integration:Ethernet to PowerShield Link software

Allows review at all levels – control room, facility managers, service providers, equipment suppliers. Both life trend and discharge event data presented Battery data stays under your control & ownership

ModbusRTU/TCP or SNMP to local building management system Integrate with existing facility systems Allows implementation of multiple alarm sets

Dry contacts for additional alarm outputs or actionsDedicated serial port for local service & diagnostics

High visibility & ownership of your battery assets.

Page 9: PowerShield  Battery Monitoring Systems protecting your power supply

P r o t e c t i n g y o u r p o w e r s u p p l y 9

Accessing Your Battery Data

Page 10: PowerShield  Battery Monitoring Systems protecting your power supply

P r o t e c t i n g y o u r p o w e r s u p p l y 10

PowerShield Link Software

New Dashboard screen for Link – see all the batteries in your facility at a single screen.

Fast overviewOnscreen alarm pop-upsSingle click for site reportSimple colour coded buttonsDrill down to battery specific

detail & alarmsMulti-seat, multi-user

Page 11: PowerShield  Battery Monitoring Systems protecting your power supply

11

PowerShield Link Software

Permanent connection to multiple sites – unlimited total number of batteries

Real time battery status, including dischargeRemote access via LANAlarm & activity logEmail alarm alertsBattery database for life trendingGraphing & analysis toolsAutomated data management

Battery management is more than just waiting for alarms

P r o t e c t i n g y o u r p o w e r s u p p l y

Page 12: PowerShield  Battery Monitoring Systems protecting your power supply

P r o t e c t i n g y o u r p o w e r s u p p l y 12

PowerShield Link Software

Comprehensive user report set Preformatted PDF or Raw CSV data

Facility summaryDischarge – individual events in detail,

activity summaryTrending – Impedance change, end-of-life,

charge voltage, temperatureAlarm history, fault tracking, service log Warranty claim support documentation Reports suitable for management & service teams

Independent remote Reporting Service available

Page 13: PowerShield  Battery Monitoring Systems protecting your power supply

P r o t e c t i n g y o u r p o w e r s u p p l y 13

PowerShield Users

Equinix – Hong Kong, Singapore, Australia, New Zealand

HP – Austin TX, Australia

IBM – Australia, New Zealand, UK, South Africa, France

Bank of America – UK, Hong Kong, Singapore, Australia

Microsoft - Ireland

Huawei - China

Bloomberg - global

Barclays Bank – UK

"PowerShield gives us the confidence to get on with running our business with the peace of mind that, should there be a power outage, our backup battery is in A1 condition." - Television New Zealand

Page 14: PowerShield  Battery Monitoring Systems protecting your power supply

P r o t e c t i n g y o u r p o w e r s u p p l y 14

PowerShield Ltd

Developing battery monitoring solutions since 1996

In-house hardware & software teams

Strong R&D team with continuous product development and battery research

Independent of battery & UPS suppliers

CTO is working group member of the IEEE Stationary Battery Committee. Current Vice Chair of IEEE 1491 Guide for Selection and Use of Battery Monitoring Equipment in Stationary Applications.

Page 15: PowerShield  Battery Monitoring Systems protecting your power supply

P r o t e c t i n g y o u r p o w e r s u p p l y 15

PowerShield Ltd

Global reach, local focus PowerShield technical & reseller support in territory – USA, Singapore, UK Stock holdings – USA, Singapore, UK Factory trained installation partners globally support@ - direct access to factory support if required

www.powershield.com

Page 16: PowerShield  Battery Monitoring Systems protecting your power supply

P r o t e c t i n g y o u r p o w e r s u p p l y 16

Notes: What We Measure & Why

Individual block voltage – ensure correct charge and performance under load

Individual block impedance – impedance change gives a solid life trend and end of life assessment.

Ambient temperature at the cabinet/rack – high temperatures kill batteries. A 10°C increase gives a 50% decrease in life expectancy

String current – allows detection of unbalanced strings, and provides rapid understanding of battery activity

String voltage – confirmation of UPS operation & compliance with battery specification

Individual block temperature [optional] – better knowledge of temperature gradients in cabinets; pre-empt thermal runaway

Page 17: PowerShield  Battery Monitoring Systems protecting your power supply

P r o t e c t i n g y o u r p o w e r s u p p l y 17

Looking After Your Batteries

A 10°C increase gives a 50% decrease in life expectancy

Page 18: PowerShield  Battery Monitoring Systems protecting your power supply

P r o t e c t i n g y o u r p o w e r s u p p l y 18

Looking After Your Batteries

Incorrect float voltage significantly affects life expectancy