powergear leaflet engelsleaflet+engels+-+web.pdf · safety ∙ hi-pot-test: 3,75 kv, 100% for 2...
TRANSCRIPT
-
PGE bv | Powergear Europe | [email protected] www.powergear.eu | +31 76 3031 405 | Breda | The Netherlands
Driver designed andmanufactured in Europe
SAFETY
AMBIENT
EMI
PROTECTIONS
DIMMING AP/PWM controlled by DALI signal. Minimum dimming level 1%. AM dimming from 100% to 25% load.
PWM dimming from 25% to 1% load.
Against input over voltages from mains (according to EN61547) up to
2KV N-L, 4KVN-GND, 4KV L-GND.
Against short circuit and open circuit.
Thermal protection (C.5.e from EN613471).
According to EN55015.
Tc = 75ºC.
Tc life 50000h = 75ºC.
Case IP00
Hi-Pot-Test: 3,75 kV, 100% for 2 sec.
∙ Nominal: 220-240 Vac±10% 50/60Hz.
∙ 0,5mm² cables, double insulated BLUE,
single isolated BROWN for L-N inputs.
∙ Max Input Current: 0,20A.
∙ Power factor: 0,97.
∙ Harmonic content of mains current:
according to EN61000-3-2-2.
∙ Inrush current: 5A.∙ SELV insulation on output.∙ Terminal block, up to 1x0,2 0,5mm².∙ Selection of current and voltage output through DIP-switch (see table).∙ Max output power and current precision @220-240Vac:
∙ Max. Output voltage: 59VDC.
∙ Efficiency @full-load: 86%.RIPPLEFREE
C
M
Y
CM
MY
CY
CMY
K
1901230 Powergear Leaflet - PRO-T6700 [Drukklaar].pdf 2 04/02/2019 16:03:54
-
SAFETY ∙ Hi-Pot-Test: 3,75 kV, 100% for 2 sec.
AMBIENT
EMI
PROTECTIONS
∙ Tc = 80°C.
∙ Tc life 50000H = 80°C.
∙ Case IP00.
∙ According to EN55015.
∙ Against input over voltages from mains (according to EN61547) up
to 2KV N-L, 4KV N-GND, 4KV L-GND.
∙ Against short circuit.
∙ Thermal protection (C.5.e from EN61347- 1).
∙ Nominal: 220-240 Vac±10% 50/60Hz.
∙ 2x Terminal block 0,2...0,75mm².
∙ Max Input Current: 0,25A.
∙ Power factor: 0.97.
∙ Harmonic content of mains current:
according to EN61000-3-2.
∙ Inrush current: 5A. ∙ SELV-Insulation on output.∙ Terminal block, up to 1 x 0,2...0,5mm².∙ Selection of current and voltage output through Dip-switch.∙ Max output power and current precision @ 220-240Vac:
∙ Max. Output voltage: 59VDC.∙ Efficiency @full load: 86%min.
∙ EN 61347-1; EN 61347-2-13; EN 61547;
EN 55015; EN 61000-3-2;
DIN VDE 0710 teil 14.
∙ KEMA KEUR; ENEC 05 Pending.
PGE bv | Powergear Europe | [email protected] www.powergear.eu | +31 76 3031 405 | Breda | Die Niederlande
Driver designed andmanufactured in Europe
RIPPLEFREE
C
M
Y
CM
MY
CY
CMY
K
1901230 Powergear Leaflet - PRO-41050 - [Drukklaar].pdf 2 04/02/2019 16:04:48