power u ps hip3300 -500 kva

52
AUSTRALIA AUSTRALIA PowerUps UPS PowerUps UPS HIP3300 Series HIP3300 Series 3Phase/3Phase series

Upload: rickyhwk

Post on 11-Aug-2015

262 views

Category:

Sales


10 download

TRANSCRIPT

Page 1: Power u ps hip3300 -500 kva

AUSTRALIA AUSTRALIA

PowerUps UPSPowerUps UPS

HIP3300 SeriesHIP3300 Series

3Phase/3Phase series

Page 2: Power u ps hip3300 -500 kva

HIP series

Module design Online UPS System

Power capacity: 10-500kVA

Page 3: Power u ps hip3300 -500 kva

1. Summary

2. Appearance

3. Display

4. Principle

5. Supplement

6. Communication

7. Specification

Catalog

Page 4: Power u ps hip3300 -500 kva

Mission critical & industrial applications

Operator Centres, Servers, Computer rooms, Telecom Switchgear & Infrastructures, Processing Control Equipments, Security Systems, Emergency Lighting, Fire Protection, Airport Infrastructure, Bank, Hospital, Healthcare Equipment …

Page 5: Power u ps hip3300 -500 kva

Main Features

Digital Signal Processor Control and PFC technology Wide Input Voltage and Frequency Windows Compatible with generator Zero transfer time Output Power Factor at 0.9 or 0.8 (optional) Sinusoidal input current THDI ≤ 2% High efficiency can reach up to 95% Superior MTBF(> 200,000 hrs)and MTTR ( <30 min.) ECO mode for energy saving

Page 6: Power u ps hip3300 -500 kva

Main Features

Optional Battery Voltage from ± 192Vdc to ± 240Vdc Intelligent with three stages charging Modes Adjustable charging current Battery Temperature Compensation Advanced battery management Matching internal Battery also Available

Page 7: Power u ps hip3300 -500 kva

Main Features

Smart Fan Speed Control Both EPO and REPO (Remote EPO) Functions Parallel Redundancy up to 4 Units Common or Separate Battery pack in parallel system Reliable protection function Easy-to-operate LCD display Megatec/Modbus Protocol Versatile Communication Interfaces

Page 8: Power u ps hip3300 -500 kva

1. Summary

2. Appearance

3. Display

4. Principle

5. Supplement

6. Communication

7. Specification

Page 9: Power u ps hip3300 -500 kva

10-80kVA 100-160kVA 200-300kVA 400-500kVA

Page 10: Power u ps hip3300 -500 kva

10/15/20KVA   

Front View(internal) Rear View (internal)

Front View(internal) Rear View (internal)

Page 11: Power u ps hip3300 -500 kva

30/40K Front view (internal) 30/40k Rear view (internal)

30/40kVA

Page 12: Power u ps hip3300 -500 kva

60/80KVA front view ( internal ) 60/80KVA rear view ( internal )

60/80kVA

Page 13: Power u ps hip3300 -500 kva

100-160KVA

100/120KVA 160KVA

Page 14: Power u ps hip3300 -500 kva

200KVA

Page 15: Power u ps hip3300 -500 kva

250-300KVA

Page 16: Power u ps hip3300 -500 kva

400-500KVA

Page 17: Power u ps hip3300 -500 kva

Power module Qty per unit

10-20K 30K 40K 60K 80K 100K

PF0.8 1 1 2 2 3 4

PF0.9 1 2 2 3 3 4

120K 160K 200K 250K 300K 400K 500K

PF0.8 4 6 5 7 8 10 13

PF0.9 5 6 5 7 8 10 13

Page 18: Power u ps hip3300 -500 kva

Dimension and weightModel Dimension (W*D*H) Weight (kg)10KVA (S/H) 600×780×1200 591(S)/123(H)

15KVA (S/H) 600×780×1200 594(S)/126(H)

20KVA (S/H) 600×780×1200 595(S)/127(H)

30KVA (S/H) 600×780×1200 595(S)/127(H)

40KVA 600×780×1200 158

60KVA 600×780×1200 158

80KVA 600×780×1200 195

100KVA 600×780×1600 286

120KVA 600×780×1600 286

160KVA 600×780×1600 348

200KVA 600×850×1600 380

250KVA 600×850×2000 541

300KVA 600×850×2000 575

400KVA 1200×850×2000 900

500KVA 1200×850×2000 1005

Page 19: Power u ps hip3300 -500 kva

1. Applications

2. Appearance

3. Display

4. Principle

5. Supplement

6. Communication

7. Specification

Page 20: Power u ps hip3300 -500 kva

LCD panelLCD panel

100-500k

10-80k

Page 21: Power u ps hip3300 -500 kva

LCD Display ( 10-80K ) Operational status and mode

Input/output Voltage/Frequency

Battery Voltage/Current

Load capacity

Charge Modes/Charger Status

Internal/Ambient Temperature

Software version & model

Alarm Codes

Page 22: Power u ps hip3300 -500 kva

LCD Display ( 100-500K )

Page 23: Power u ps hip3300 -500 kva

Rich settings ( 10-80K) Mode setting Output voltage and frequency setting Bypass voltage upper/lower limit setting

Page 24: Power u ps hip3300 -500 kva

Display

Rich settings (10-80K) Parallel ID/quantity/redundancy quantity setting

Battery capacity/quantity setting

Page 25: Power u ps hip3300 -500 kva

Rich setting ( 100-500K )

Page 26: Power u ps hip3300 -500 kva

1. Summary

2. Appearance

3. Display

4. Principle

5. Supplement

6. Communication

7. Specification

Page 27: Power u ps hip3300 -500 kva

System block diagram

EMI PFC

LCD

BATTERY

BYPASS

BUS INVERTER EMI

AUX POWER

CHARGER

COMMUNICATION

DSP

PARALLELBOARD

I/P O/P

Page 28: Power u ps hip3300 -500 kva

Power unit block diagram

Page 29: Power u ps hip3300 -500 kva

Cabinet block diagram (10-160k)

Page 30: Power u ps hip3300 -500 kva

Cabinet block diagram (200-500k)

Page 31: Power u ps hip3300 -500 kva

Power unit Topology

Page 32: Power u ps hip3300 -500 kva

Working mode

√ Normal mode√ Battery mode (Stored Energy Mode)√ Bypass mode√ Maintenance mode (Manual Bypass)√ ECO Mode√ Parallel redundancy mode (system expansion)

Page 33: Power u ps hip3300 -500 kva

1. Summary

2. Appearance

3. Display

4. Principle

5. Supplement

6. Communication

7. Specification

Page 34: Power u ps hip3300 -500 kva

Supplement

Powerful Charger

Model 10-30k

40-60k 80k 100k 120k 160k 200k 250k 300k 400k 500k

Max charge current

5.7/6A 12A 18A 24A 30A 36A 50A 70A 80A 100A 130

A

Page 35: Power u ps hip3300 -500 kva

Protection type (breaker in bypass mode)

Model 10k 15k 20k 30k 40k 60k 80k

Breaker 20A 32A 40A 50A 80A 100A 125A

Model 100-120k 160k 200k 250-300k 400-500k

Breaker 225A 250A 400A 500A 800A

Page 36: Power u ps hip3300 -500 kva

Built-in Battery

HIP10-30KVAwith 36pcs 38AH

Page 37: Power u ps hip3300 -500 kva

De-rating Operation Available Normal operation Temperature 0~40 C Max. operation Temperature 50 C De-rating operation: 10% per 5 C

Page 38: Power u ps hip3300 -500 kva

Fan Speed Control

Fan running according to load percentage 50%: slow speed over 50%: full Speed

Page 39: Power u ps hip3300 -500 kva

Battery Temperature Compensation Auto-adjusted without any human involvement Compensate from 20 C: Reduce 0.001V*6 of floating voltage per 1 C. 0.002~0.006V * 6 per 1 C settable

Page 40: Power u ps hip3300 -500 kva

Battery Voltage Configurable ±192V\±204V\±216V\±228V\±240Vdc Configurable Selection of the most suitable battery qty & capacity Decrease Initial Investment

Page 41: Power u ps hip3300 -500 kva

3-Stage Intelligent Charging Modes

Constant Current Constant Voltage Floating (Boost Charge 2.30V to 2.35V per cell &Float Charge 2.20V

to 2.29V per cell)

Page 42: Power u ps hip3300 -500 kva

1. Summary

2. Appearance

3. Display

4. Principle

5. Supplement

6. Communication

7. Specification

Page 43: Power u ps hip3300 -500 kva

Versatile Communication Interfaces

RS485 Ports RS232 Port USB port (for 100-500k) Parallel Port Dry contact SNMP slot

Page 44: Power u ps hip3300 -500 kva

Optional card

Megatec Protocol Supported SNMP Card (BP506)

Page 45: Power u ps hip3300 -500 kva

Optional card Dry contact relay

10-500k

option for 100-500k

Page 46: Power u ps hip3300 -500 kva

Monitoring software (Muser4000)

Page 47: Power u ps hip3300 -500 kva

1. Summary

2. Appearance

3. Display

4. Principle

5. Supplement

6. Communication

7. Specification

Page 48: Power u ps hip3300 -500 kva
Page 49: Power u ps hip3300 -500 kva
Page 50: Power u ps hip3300 -500 kva
Page 51: Power u ps hip3300 -500 kva
Page 52: Power u ps hip3300 -500 kva