power quality analyzers & data loggers...pm4000 pm3000hf pm2000f pm2000f-300 pm7000 flm pm7503...

8
POWER QUALITY ANALYZERS & DATA LOGGERS Volts, Amps, KW, VARS, PF, Phase Angle, Harmonics, Interharmonics, Flicker, Transients, and Waveform Capture (248) 656-2727 (800) 338-4505 [email protected] rangerpq.com

Upload: others

Post on 29-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • POWER QUALITY ANALYZERS & DATA LOGGERS

    Volts, Amps, KW, VARS, PF, Phase Angle, Harmonics, Interharmonics, Flicker, Transients, and Waveform Capture

    (248) 656-2727 (800) 338-4505 [email protected] rangerpq.com

  • Four 24" 6000A/400.0A Flexible Current Clamps (other lengths available)

    Five Fused Voltage probes 600V

    Pronto for Windows Analysis Software

    16GB Flash Drive for Expanded Memory

    Bluetooth Adapter for Laptop or PC

    12 Volt Charger & Carrying Case

    1 year warranty

    No cost lifetime upgrades for Software & Firmware

    PM7000 POWER QUALITY RECORDING ANALYZER

    (248) 656-2727 (800) 338-4505 [email protected] rangerpq.com

    Each Unit Includes:

    2

    Auto-ranking of waveform capture greatest disturbances-Ranger exclusive

    Records 32 Detail Channels simultaneously with single cycle resolution on changes, because of our Exclusive Patented Single Cycle Adaptive Store

    128 MB on board memory. Expandable memory though USB Flash Port that automatically writes to drive when recording finishes

    Wireless communications to remote PC or Android Device allows access to PM7000 display, without suiting up as required by NFPA 70

    Compliant to IEEE 1453 Flicker Specification. Only Ranger Loggers measure Instantaneous Flicker

    High speed sampling on ALL inputs including 4 Currents and 4 Voltages

    Input leads fusing is Standard

    lnterharmonics Option

    Why you should consider a PM7000

    Quick Specs

    Voltage Channels 4 (0-600 VAC)

    Current Channels 4 (2 ranges- 6000A or 400.0A)

    PowerRequirements 90–660 VRMS(V1), 12Vdc (DC Charger)

    RecordingChannels 32 Detailed, >470 General Parameters

    SampleRate

    PM7000S @ 320 Samples/cyclePM7000H @ 2,056 Samples/cyclePM7000T @ 20,480 Samples/cycle

    Memory storage forrecorded data

    128MB, Expandable with External Flash Drive

    Communications Bluetooth, USB, USB Flashdrive, Ethernet, Remote

    WaveformTriggers

    WaveformMemory

    Transient, Ring, Sag, Swell, RMS Fall,THD Current, THD Voltage

    32 MB

  • (248) 656-2727 (800) 338-4505 [email protected] rangerpq.com

    3

    Four 24" 6000A/400.0A Flexible Current Clamps (other lengths available)

    Five Fused Voltage probes 600V

    Pronto for Windows Analysis Software

    16GB Flash Drive for Expanded Memory

    Bluetooth Adapter for Laptop or PC

    12 Volt Charger & Carrying Case

    1 year warranty

    No cost lifetime upgrades for Software & Firmware

    PM4000 POWER QUALITY RECORDING ANALYZER

    (248) 656-2727 (800) 338-4505 [email protected] rangerpq.com

    Each Unit Includes:

    Auto-ranking of waveform capture greatest disturbances-Ranger exclusive

    Records 32 Detail Channels simultaneously with single cycle resolution on changes, because of our Exclusive Patented Single Cycle Adaptive Store

    32 MB on board memory. Expandable memory though USB Flash Port that automatically writes to drive when recording finishes

    Wireless communications to remote PC or Android Device allows access to PM4000 display, without suiting up as required by NFPA 70

    Compliant to IEEE 1453 Flicker Specification. Only Ranger Loggers measure Instantaneous Flicker

    High speed sampling on ALL inputs including 4 Currents and 4 Voltages

    Input leads fusing is Standard

    lnterharmonics Option

    Why you should consider a PM4000

    Quick Specs

    Voltage Channels 4 (0-600 VAC)

    Current Channels 4 (2 ranges- 6000A or 400.0A)

    PowerRequirements

    90–660 VRMS(V1), 12Vdc (DC Charger)

    RecordingChannels 32 Detailed

    SampleRate

    320 Samples/cycle

    Memory storage forrecorded data

    32MB, Expandable with External Flash Drive

    Communications Bluetooth, USB, USB Flashdrive, Ethernet, Remote

    WaveformTriggers

    WaveformMemory

    Transient, Ring, Sag, Swell, RMS Fall,THD Current, THD Voltage

    2 MB

  • 4

    (248) 656-2727 (800) 338-4505 [email protected] rangerpq.com

    Three 24" 6000A/400.0A Flexible Current Clamps (other lengths available)

    Four Fused Voltage Input Cables

    Pronto for Windows Analysis Software

    12 Volt Charger & Carrying Case

    8 MB Memory and Bluetooth Capability

    1 year warranty

    No cost lifetime upgrades for Software & Firmware

    PM3000 POWER QUALITY RECORDING ANALYZER

    (248) 656-2727 (800) 338-4505 [email protected] rangerpq.com

    Each Unit Includes:

    Records 16 Detail Channels simultaneously with single cycle resolution on changes, because of our Exclusive Patented Single Cycle Adaptive Store

    Wireless communications to remote PC or Android Device allows access to PM3000 display, without suiting up as required by NFPA 70

    Records and displays harmonics: Odd, Even, Triplens, THD%, and individual harmonics (including harmonic direction} to the 15th

    Compliant to IEEE 1453 Flicker Specification. Only Ranger Loggers measure Instantaneous Flicker

    High speed sampling on ALL inputs including 3 Currents and 3 Voltages

    Optional DC Measurement

    Input leads fusing is Standard

    Easy to use graphical touchscreen

    Why you should consider a PM3000Quick Specs

    Voltage Channels 3 (0-525 VAC)

    Current Channels 3 (3 ranges- 6000A/ 400.0A/50.00A)

    PowerRequirements

    100-500 VAC from L1 to L2, 12Vdc (DC Charger)

    RecordingChannels 16 Detailed

    SampleRate

    3,840 Samples/sec

    Communications Bluetooth, USB, Remote

    Memory 8MB, 16MB, 32MB

    5 pre-stored configurations for quick set-up

  • (248) 656-2727 (800) 338-4505 [email protected] rangerpq.com

    Neutral Blade and Neutral Clip Lead

    Infrared USB Download Cable

    Pronto for Windows Analysis Software

    12 Volt Charger & Carrying Case

    1 MB Memory and Bluetooth Capability

    1 year warranty

    No cost lifetime upgrades for Software & Firmware

    PM2000 POWER QUALITY METER SOCKET LOGGERS

    (248) 656-2727 (800) 338-4505 [email protected] rangerpq.com

    Each Unit Includes:

    PM2000-300BT

    Records 16 Detail Channels simultaneously with single cycle resolution on changes, because of our Exclusive Patented Single Cycle Adaptive Store

    PM2000F-300BT version for socket class 320 (also compatible with socket class 200).

    Compliant to IEEE 1453 Flicker Specification. Only Ranger Loggers measure Instantaneous Flicker

    Recording automatically starts after 1 minute of installation

    Why you should consider a PM2000Quick Specs

    Voltage Channels 5 (0-500 VAC)

    Current Channels 2 (0-220A)

    PowerRequirements

    50-525 VRMS (Vl), 12Vdc (DC Charger)

    RecordingChannels

    16 Detailed

    SampleRate 3,840 Samples/sec

    Communications Bluetooth, Infrared, Remote

    Memory 1 MB RAM

    L1 to L2 is measured, not calculated

    Pre-stored configurations for quick set-up

    5

  • PM7000

    RANGER FULL SPEC SHEET COMPARISON

    PM4000 PM3000HF PM2000F PM2000F-300 PM7000 FLM PM7503

    Interharmonics

    THD and THC

    kW

    KVA

    KVAR

    Power Factor

    Unbalance (V & I)

    InRush Current

    4 (0-600 VAC)

    Memory storage for recorded data

    GeneralParameters*1

    DetailedRecording Channels

    Sample Rate

    Current Channels

    Voltage Channels

    32

    4 (2 ranges- 6000A or 400.0A)

    128MB

    Optional

    Optional

    50th (127th Optional)

    PM7000S @ 320 Samples/cycle PM7000H @ 2,056 Samples/cycle

    PM7000T @ 20,480 Samples/cycle

    Expandable Memory with a memory Stick or Hard Drive

    Flicker (Plt, Pst, Pinst, Pflag)

    Highest order of individual harmonics*2

    Frequency 45-65Hz (can automatically detect 50 or 60Hz nominal)

    4 (0-600 VAC)

    32

    4 (2 ranges- 6000A or 400.0A)t

    32MB

    50th

    320 Samples/cycle

    3 (0-525 VAC)

    16

    3 (2 ranges- 6000A or 400.0A)

    8MB, 16MB, 32MB

    15th N/A N/A

    3,840 Samples/sec

    3 (0-300 VAC True RMS)

    16

    2 (Two 0-220 Amp Rogowski Type

    Rigid Coil Sensors)

    1MB

    3,840 Samples/sec

    3 (0-300 VAC True RMS)

    16

    2 (Two 0-300 Amp Rogowski Type

    Rigid Coil Sensors)

    1MB

    3,840 Samples/sec

    4 (0-600 VAC)

    32

    4 (2 ranges- 6000A or 400.0A)

    128MB

    Optional

    50th (127th Optional)

    320 Samples/cycle 19.2k Samples/sec

    4 (0-600 VAC, 0-300 VDC)

    32

    4 (0-1V RMS. Current to Voltage CT’s

    supplied, nominal input 1A)

    Measures to Class A or more accurate

    Measures to Class A or more accurate

    Measures to Class A or more accurate

    Measures to Class A or more accurate

    Class S

    128MB

    Optional

    50th (127th Optional)

    IEC6100-4-30

    Symmetrical Components

    DC Measurement

    K Factor

    6

  • PM7000 PM4000 PM3000HF PM2000F PM2000F-300 PM7000 FLM PM7503

    Transient detection

    Time Interval Store

    Single Cycle Adaptive Store

    (both cycle & sub-cycle)

    32MB 32MB 32MB2MB

    Sag / Swell / Outage Monitoring

    High Speed Waveforms with AutoRanking Waveform Capture

    CBEMA / ANSI / ITIC curve plots

    Onboard Display

    Bluetooth

    Ethernet

    USB or Infra-Red Communication

    Remote screen with PMScreen

    Waveform Capture Memory

    Remote Communications via PMGateway

    Time Synchronization over mobile phone or PC

    Baud Rate

    Power Requirements

    Portable/Fixed

    Dimension

    Weight

    Operating Temperature

    Accuracy

    Safety Rating

    IP Rating

    Software

    N/A N/A N/A

    USB USB USBUSB USB Infra-Red Infra-Red

    P P FP P P P

    9" x 7.5" x 4.3" 9" x 7.5" x 4.3" 11.3" x 8.1" x 2.8" 9" x 7.5" x 4.3" 8" x 6.5" x 3.5" 6.75" x 6.75" x 5" 6.75" x 6.75" x 6"

    -20 to 60°C -20 to 60°C -20 to 60°C-20 to 60°C -10 to 60°C -30 to 65°C -30 to 65°C

    IP65 IP65 IP40IP65 IP51 N/A N/A

    Pronto for Windows Pronto for Windows Pronto for WindowsPronto for Windows Pronto for Windows Pronto for Windows Pronto for Windows

    7.7lbs 7.7lbs7.7lbs 2.5lbs 2.6lbs 2.6lbs

    Up to 921.6k Up to 921.6k Up to 921.6kUp to 921.6k 115.2k 115.2k 115.2k

    (both cycle & sub-cycle) (down to single cycle) (down to single cycle) (down to single cycle) (both cycle & sub-cycle) (both cycle & sub-cycle)

    Powered from V1 input (90-660 VRMS, 15W

    Max) OR from charger input @ 12Vdc, 6W Max.

    Powered from V1 input (90-660 VRMS, 15W

    Max) OR from charger input @ 12Vdc, 6W Max.

    Powered from V1 input (50-525 VRMS,) OR from charger input @ 12Vdc,

    6W Max.

    Volts and wide range current < 0.25% True RMS Narrow range

    current < 1% True RMS

    0.2%. 0.1% in reference range 20-30°C

    (excluding sensors). +/-2LSB.

    < 0.25% excluding sensors, +/- 2LSDs (in

    target ranges)

    < 0.25% excluding sensors, +/- 2LSDs (in

    target ranges)

    0.2%. 0.1% in reference range 20-30°C

    (excluding sensors). +/-2LSB.

    Voltage < 0.25% True RMS of Reading

    Current < 0.5% True RMS of Reading

    Voltage < 0.25% True RMS of Reading

    Current < 0.5% True RMS of Reading

    100-300 Vac from L1 to L2 voltage

    measurement or separate power supply

    100-300 Vac from L1 to L2 voltage

    measurement or separate power supply

    Powered from V1 input (90-660 VRMS, 15W

    Max) OR from charger input @ 12Vdc, 6W Max.

    Optional Optional Optional

    600V Cat IV, 1000V Cat III (Fuses removed)

    600V Cat IV, 1000V Cat III (Fuses removed)

    600V Cat III 600V Cat III 600V Cat III 600V Cat III600V Cat IV, 1000V Cat III (Fuses removed)

    PM7000S @ 320 Samples/cycle PM7000H @ 2,056 Samples/cycle

    PM7000T @ 20,480 Samples/cycle

    320 Samples/cycle 3,840 Samples/sec 3,840 Samples/sec 3,840 Samples/sec 320 Samples/cycle 19.2k Samples/sec

  • 21623 E. 9 Mile Rd, Saint Clair Shores, MI 48081

    (248) 656-2727 (800) 338-4505 [email protected] rangerpq.com

    ASK US ABOUT...

    Pronto for Windows Software Pronto Windows Software

    Still have questions?

    Reach out to us by calling the number below so we can answer any

    questions you might have.

    (248) 656-2727

    PM7000 Fault Level Monitor 5A Secondary Current Transformers (CTs) Monitoring

    PM7503 Panel Mount Power Quality Analyzer

    Meter Socket Interface