power panelboards tmax xt retrofit kits for …...single mount kits 01 available for 250 a, 600 a,...
TRANSCRIPT
—POWER PANELBOARDS
Tmax XT Retrofit Kits for Spectra PanelboardsExtending the life of your Installation
— by ABB
—Your trusted partner
KEEP RUNNINGYour operation is critical. Your goal is to extend the life of your installation. These Tmax XT Retro-fit Kits keep your Spectra Panelboards opera-tional and help to minimize costs due to down time.
UPDATE YOUR INSTALLATION Update your Spectra Panelboards with the latest in breaker technology. These retrofit kits enable the installation of the Tmax XT family of molded case breakers. You benefit by gaining the latest capability in circuit protection, communications, and predictive maintenance technologies.
GET WHAT YOU NEED WHEN YOU NEED ITYou run lean. You need replacement parts today. Our wide network of distributors give you access to the products you need, when you need them.
2
— Table of contents
004 – 005 Tmax XT Retrofit Kits for Spectra Panelboards
006 – 007 Choosing the right retrofit has never been so easy
008 – 009 The Tmax XT range at a glance
010 – 010 Electronic trip units Ekip Dip and Ekip Touch
011 – 011 Spectra Panelboard Accessories for Tmax XT
3
Single mount kits01 available for 250 A, 600 A, 1200 A frames
—01 Maximum of two Tmax XT4, XT5 or XT7 retrofit kits can be installed, side by side, in an existing Spectra panelboard installation
4
—Tmax XT Retrofit Kits for Spectra Panelboards The right choice for your application
Dual mount kits01 available for 150 A, 250 A, 400 A frames
5
6
—Choosing the right retrofit has never been so easyYou consider what you need. We will show you what's possible
Step 1. Select breaker and trip unit
Step 2. Select retrofit kit Step 3. Enter separate breaker and rertrofit kit orders through empower.abb.com using desktop, laptop or mobile devices.
ABB Empower
Step 4. Receive breaker and ret-rofit kit shipments
— 01 Maximum of two Tmax XT4, XT5 or XT7 retrofit kits can be installed, side by side, in an existing Spectra panelboard installation
The world of electrical distribution is a complex one, yet choosing the right device for your individual needs has never been simpler thanks to this Tmax XT retrofit01 offering for Spectra Panelboards. May be you are looking for a basic pro-tection device for a standard distribution system.
Or perhaps you need something more complex, such as a lock-ing mechanisms or devices that integrate protection, automa-tion, measuring and communication into a cloud-based super-vision system. We have whatever you are looking for, with a wealth of customization possibilities and a range of possible solutions depending on your needs.
7
— 02 XT7 breaker handle extension included in this kit
— 01 Maximum of two Tmax XT4, XT5 or XT7 retrofit kits can be installed, side by side, in an existing Spectra panelboard installation
Possible combinations within the range
Legacy Spectra breaker
Spectra E Frame Spectra F Frame Spectra G Frame Spectra K Frame
Tmax XT Breaker
Tmax XT1 Tmax XT4 Tmax XT5 Tmax XT7
Heavy duty
Basic functionality
Thermal-magnetic trip units
Electronic trip units
125 A 250 A 250 A 600 A 600 A 1200 A
Legacy Spectra based Kit AMCB6EBFP AMCB6FJFP AMCB3FJFP AMCB6GBFP AMCB3GMFP AMCB3KMFP
Tmax XT Kit01 SRFB6XT1FPX SRFB6XT4FPX SRFB3XT4FPX SRFTB6XT5BFPX SRFB3XT5MFPX SRFB3XT7MFPX02
Tmax XT Kit with Kirk Provisions01 SRFB6XT1FPK SRFB6XT4FPK SRFB3XT4FPK SRFB6XT5BFPK SRFB3XT5MFPK SRFB3XT7MFPK02
SRFN400GF XT5 UL 400 A NEUTRAL CURRENT TRANSFORMER KIT
SRFN600GF XT5 UL 600 A NEUTRAL CURRENT TRANSFORMER KIT
SRFN800GF XT7 UL 800 A NEUTRAL CURRENT TRANSFORMER KIT
SRFN1000GF XT7 UL 1000 A NEUTRAL CURRENT TRANSFORMER KIT
SRFN1200GF XT7 UL 1200 A NEUTRAL CURRENT TRANSFORMER KIT
8 TM A X X T M O L D ED C A SE CI R C U IT B R E A K ER S (M CCB S U L & C S A S TA N DA R DS)
—The Tmax XT range at a glanceThe world of breaking capability in your hands. According to UL 489 and CSA C22.2 Standards
SACE Tmax XT1"The Founder"
Small, reliable, versatile. Your dependable partner for all standard applications.
At a glance:• 125 A frame available up to 480 V Delta UL• Thermal-magnetic, MCS and MCP trip units • Max. interrupt rating of 65 kA at 480 V• Offers savings versus 600 V-rated systems in
most disrtibustion applications
SACE Tmax XT4"The Entrepreneur"
Capable of supporting both simpleand extremely complex operations.
At a glance:• 250 A frame available up to 600 V UL• Thermal-magnetic, MCS, MCP, basic and
advanced electronic trip units • Max. interrupt rating of 200 kA at 480 V, 100 kA
at 600 V• Adavnced electronic trip units offer embedded
Bluetooth communication for interaction without direct contact
SACE Tmax XT takes circuit breaking to the next level. Designed to perform at extremely high levels, simple to install and able to provide higher level of safety, there's a frame to meet each of your requirements. From a basic solution for commercial and light industrial applications to advanced, heavy-duty applications with cloud connectivity, SACE Tmax XT has you covered: securely, professionally and reliably.
9
SACE Tmax XT5"The Gamechanger"
Compact, powerful and flexible. Shows the world what a circuit breaker of the future can do.
At a glance:• 600 A frame available up to 600 V UL• Thermal-magnetic, MCS, MCP, basic and
advanced electronic trip units • Max. interrupt rating of 200 kA at 480 V, 100 kA
at 600 V• Adavnced electronic trip units are future-ready
with the ability to download additional measurements and logic in the field from the ABB MarketplaceTM
SACE Tmax XT7"The Superhero"
The ultimate choice. Deals with heavy-duty demands effortlessly.
At a glance:• 1200 A frame available up to 600 V UL• MCS, MCP, basic and advanced electronic trip
units • Max. interrupt rating of 100 kA at 480 V, 65 kA
at 600 V• A powerful package capable of monitoring and
controlling distribution
—Electronic trip units Ekip Dip and Ekip TouchThe network under control
When it comes to accurate protection of the network, you cannot go wrong with Ekip Dip and Touch technology.
Prot
ecti
on
and
info
rmat
ion
Accuracy
Thermal-magnetic
Ekip Touch
Ekip Dip
Applications Advanced functionalities
Distribution Generator Selectivity Metering Communication ABB Ability MarketplaceTM
DC AC
Touch
Dip
TM
Thermal-magnetic trip units Thermal-magnetic trip units are intended for the protection of AC and DC networks. They are a solution for basic protection such as overloads and short-circuits.
Ekip Dip trip unitsEkip Dip trip units represent the first level of electronic trip unit and are used to protect AC networks. Compared to thermal-magnetic trip units, they can provide increased accuracy, a wider regulation range, delayed short circuit protection, indi vidual trip information and test capability.
Ekip Touch trip unitsEkip Touch trip units offer state-of-the-art technology for AC-network protection. These trip units integrate a great number of protection and automation functionalities, performed with best-in-class accuracy. Measurement and supervision data can be transmitted both on the local commu-nication network (the most popular communica-tion protocols are available) or directly over the Internet. Configuration of the trip unit is extremely user-friendly, mainly on the sizes where a colour touchscreen display is available. Further-more, as operational requirements evolve, for the first time ever customers can download new func-tions from the ABB MarketPlace, choosing among more than fifty different protection, metering and automation functionalities.
Trip unit range
The protection units available for the SACE Tmax XT range is organized in three layers, characterized by increasing performance, interfaces, information sets and integration functions.
Each layer includes several trip unit versions, de-signed to match specific application needs such as distribution, generator protection.
10 S ACE TM A X X T M O L D ED C A SE CI R C U IT B R E A K ER S (M CCB S U L & C S A S TA N DA R DS)
—Spectra Panelboard Accessories for Tmax XTThe parts you might need for your installation
11
NCT Kits
XT1 Kirk Lock
XT7 Folding Handle
XT4 Kirk Lock
XT5 Kirk Lock
XT7 Kirk Lock
© Copyright 2019 ABB. All rights reserved. Specifications subject to change without notice.
DE
A10
36-
06/
2019
—ABB Inc.305 Gregson DriveCary, NC 27511
—We reserve the right to make technical changes or modify the contents of this doc-ument without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any re-sponsibility whatsoever for potential errors or possible lack of information in this docu-ment.
ABB.com
We reserve all rights in this document and in the subject matter and illustrations con-tained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB AG. Copy-right© 2019 ABBAll rights reserved
Disclaimer : These instructions do not cover all details or variations in equipment nor do they provide for every possible contingency that may be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise that are not covered sufficiently for the purchaser's purposes, the matter should be referred to the ABB Company.