INTRODUCTION:

POWER REQUIREMENT IS INCREASING DAY BY DAY DUE TO THE MAXIMUM POWER UTILIZATION. IN ORDER TO MEET THIS DEMAND A LARGE POWER HAS TO BE GENERATED IN AN EFFICIENT WAY. A NEW MACHINE NAMELY “POWERFORMER” CAN DO THIS. THE CONVENTIONAL PLANT GENERATED VOLTAGE IS LIMITED TO 30KV. THIS VOLTAGE IS STEPPED UP TO A HIGH VOLTAGE LEVEL IN THE ORDER OF 800KV WITH THE HELP OF POWER STEP-UP TRANSFORMERS. THE STEP-UP TRANSFORMER IMPOSES GREAT DRAWBACKS ON THE POWER PLANT, STARTING FROM REDUCTION IN EFFICIENCY, HIGH MAINTENANCE COSTS, AND MORE SPACE LESS AVAILABILITY.

Page 3: Power former

• DURING THE LAST CENTURY, A NUMBER OF ATTEMPTS WERE MADE AT DEVELOPING A HIGH-VOLTAGE GENERATOR THAT COULD BE CONNECTED DIRECTLY TO THE POWER GRID, I.E. WITHOUT GOING ANY STEP-UP TRANSFORMER. THE POWERFORMER HAS OPENED A NEW CHAPTER IN THE GENERATION AND TRANSMISSION OF ELECTRICAL ENERGY.

Page 4: Power former

OBJECTIVES:

• POWERFORMER CONCEPT

• INNOVATIVE DESIGN

• THE FIRST POWERFORMER INSTALLATION

• ADVANTAGES OF POWERFORMER

Page 5: Power former

POWERFORMER CONCEPT:

• POWERFORMER IS A NEW MACHINE, IT IS A 3-PHASE AC GENERATOR WITH A ROTOR OF CONVENTIONAL DESIGN.

• THE DIFFERENCE COMPARED WITH CONVENTIONAL GENERATOR LIES IN THE STATOR WINDINGS.

• IN POWERFORMER STATOR WINDING CONSISTS OF HIGH-VOLTAGE CABLES INSTEAD OF TODAY’S WINDINGS WITH A SQUARE CROSS-SECTION.

• BY USING HIGH-VOLTAGE CABLES AS GENERATOR STATOR WINDING, IT IS POSSIBLE TO HIGHLY INCREASE THE GENERATED VOLTAGE.

• THE DECISIVE DIFFERENCE BETWEEN THIS DESIGN AND PRESENT-DAY TECHNOLOGY IS THAT POWERFORMER ALLOWS DIRECT CONNECTION TO THE HIGH-VOLTAGE GRID.

Page 6: Power former

SCHEMATIC DIAGRAM OF A CONVENTIONAL PLANT WITH STEP-UP TRANSFORMER (A), AND THE SAME PLANT WHEN THE NEW

TECHNOLOGY IS USED (B).

1 . GENERATOR 2. GENERATOR CIRCUIT BREAKER

3 . SURGE ARRESTER 4. STEP-UP TRANSFORMER

5. L INE CIRCUIT BREAKER

Page 7: Power former

•THIS DESIGN IMPLIES THE OMISSION OF THE GENERATOR CIRCUIT BREAKER, THE HIGH CURRENT BUS BAR AND THE STEP-UP POWER TRANSFORMER FROM THE POWER PLANT, BECAUSE POWERFORMER COMPRISES THE FUNCTIONS OF BOTH GENERATOR AND STEP-UP TRANSFORMER AS REALIZED FROM ABOVE FIGURE

•AS A CONSEQUENCE THERE IS AN INCREASE UP TO 1.5% IN TOTAL ELECTRIC POWER EFFICIENCY COMPARED WITH TODAY’S BEST DESIGNS, WITHOUT USING SUPERCONDUCTIVE MATERIALS.

Page 8: Power former

INNOVATIVE DESIGN:

•POWERFORMER HAS BEEN DESIGNED WITH SEVERAL UNIQUE FEATURES THAT ALLOW IT TO EXCEED THE 30KV LIMIT, INCLUDING A WINDING CONSISTING OF POWER CABLES AND AN INNOVATIVE STATOR DESIGN.

Page 9: Power former

POWERFORMER WINDINGS:

• THE WINDING CONSISTS OF A POWER CABLE WITH SOLID INSULATION AND TWO SEMICONDUCTING LAYERS, ONE SURROUNDS THE CONDUCTOR AND THE OTHER OUTSIDE THE INSULATION.

•THE INSULATION MATERIAL IS CROSS-LINKED POLYETHYLENE

• HIGH-VOLTAGE POWER CABLES ARE USED IN WINDING.

•THESE CABLES USED TO MANY ADVANTAGES OVER CONVENTIONAL DESIGNS

Page 10: Power former

A CROSS SECTION OF THE POWER CABLE USED IN THE STATOR WINDING OF POWERFORMER:

Page 11: Power former

POWERFORMER CABLE VERSUS CONVENTIONAL

RECTANGULAR CONDUCTORS:

Page 12: Power former

NON CONVENTIONAL STATOR DESIGN: THE STATOR OF POWERFORMER CONSISTS OF A LAMINATED

CORE.THESE LAMINATED CORE ARE BUILT UP FROM ELECTRICAL

SHEET. THE WINDING IS LOCATED IN THE SLOTS FORMED BY THE

TEETH, THE CROSS SECTION OF THE SLOTS DECREASES . THE WINDING TURN REQUIRES LESS CABLE INSULATION THE CLOSER IT IS TO THE ROTOR.

EACH SLOT HAS CIRCULAR BORES AT INTERVALS, FORMING NARROW WAISTS BETWEEN THE WINDING LAYERS, AS SHOWN IN FIGURE BELOW.

Page 13: Power former

SECTION OF THE STATOR IN POWERFORMER:

Page 14: Power former

THE FIRST POWERFORMER INSTALLATION:

•THE WORLD’S FIRST HIGH-VOLTAGE GENERATOR BASED ON THE NEW TECHNOLOGY; A HYDROPOWER MACHINE IS RATED AT 11 MVA, 45 KV, AND 600 RPM. THE MACHINE HAS ALREADY BEEN TESTED IN THE FACTORY AND INSTALLED AT THE PORJUS HYDROPOWER CENTER ON THE LULE RIVER IN NORTHERN SWEDEN. THE MACHINE IS DIRECTLY CONNECTED TO THE 45 KV TRANSMISSION POWER GRIDS; ITS STATOR IS SHOWN IN BELOW FIGURE

Page 15: Power former

STATOR VIEW OF THE FIRST POWERFORMER:STATOR VIEW OF THE FIRST POWERFORMER:

Page 16: Power former

1.It generates Low voltage (<30kv)

1.It generates High voltage (>>30kV)

2. High current 2. Low current

3. Stator has Short teeth 3. Stator Long teeth

4. High weight 4. Less weight

5. Mount winding is used 5. Thread cable is used

6. Impregnating windings 6. Extrusion type winding is used

7. High temperature 7. Low temperature

COMPARISON OF CONVENTIONAL GENERATOR AND POWERFORMER:

Page 17: Power former

•HIGHER EFFICIENCY

•LOW MAINTENANCE COSTS

• POWER TRANSFER FORM GENERATOR TO POWER GRID WITHOUT GOING VIA THE STEP-UP TRANSFORMER

•BETTER AVAILABILITY

ADVANTAGES OF POWERFORMER:

Page 18: Power former

CONCLUSION:

ABB’S NEW HIGH-VOLTAGE GENERATOR (POWERFORMER) HAS BEEN STUDIED THE NEW CONCEPT PROVIDES THE POSSIBILITY TO DIRECTLY CONNECT A ROTATING MACHINE TO THE HIGH-VOLTAGE POWER GRID WITHOUT GOING ANY STEP-UP TRANSFORMER. POWERFORMER IS A HIGH-VOLTAGE GENERATOR; THE LIMITATION IN ITS RATED VOLTAGE IS SET SOLELY BY THE AC

• POWER CABLE AND THE CABLE ACCESSORIES (TERMINATIONS AND JOINTS) USED IN ITS STATOR WINDING. THIS MEANS THAT POWERFORMER OF VOLTAGE RATINGS UP TO 400 KV CAN BE REALIZED, ALTHOUGH HAS NOT BEEN PROVED YET.

Page 19: Power former