power & energy industry€¦ · our scope of supply includes, electric motors, variable speed...
TRANSCRIPT
Power & energy Industry
ww
w.m
atri
x-in
dust
ries
.com
WHO WE ARE
Matrix is a global engineering solutions company with over 14 years of experience inexecuting projects in Steel & Mining, Oil & Gas, Power Generation, Utilities &Infrastructure.
We have offices in strategic locations in Europe, Middle East and Asia.
We feel its important to be close to our customers and suppliers and manage ourprojects with a local focus but stay globally connected.
ww
w.m
atri
x-in
dust
ries
.com
WHAT WE DO Our scope of supply includes, electric motors, variable speed drives, soft starts and
transformers. For use in a variety of industries for fans, blowers, compressors, pumps and other
rotating equipment.
ww
w.m
atri
x-in
dust
ries
.com
Products range
Low voltage:0.25Hp – 500Hp200V – 690V2-16 polesIE1, IE2, IE3, IE4Medium & High voltage:75Hp – 30000Hp (up to 60000 Hp Synchronous)1000 – 14500V2 – 42 polesTEFC, TEAAC, TEWAC, ODP, WPI, WPII
Medium Voltage:150kW to 25400kW2400…11000V
Motor voltage:3kV, 3.3kV, 4.16kV, 5kV, 6.6kV, 7.2kV, 10kV, 11kV, 13.8kVStarting current:50A…6000A
Distribution:Up to 69kVCast resin up to 10MVAMedium & High voltage:Up to 500kV
ww
w.m
atri
x-in
dust
ries
.com
HOW WE DO IT
We feel that our strength in the market comes from our close relationship with our customers, OEM factories and our dedicated and experience support team.
We always strive to understand our clients needs and requirements to enable us to put forward the best solution.
ww
w.m
atri
x-in
dust
ries
.com
Germany
Vietnam
Japan
Kingdom of Bahrain
Indonesia
Sri Lanka
Kingdom of Saudi Arabia
Malaysia
Nigeria
Tunisia EgyptKuwait
Jordan
Spain
United States
Iraq
United Kingdom
Brazil Austria
Italy
United Arab Emirates
Country of Customers
TECO’S capability in power generation
ww
w.m
atri
x-in
dust
ries
.com
Typical MV Motors In Power Generation
Conveyor & coal feeders
Condensate extraction pumps
Cooling water districtHeating, & co-generationpumps
Condenser & coolingTower fans
FGD Slurry & Absorberpumps
InducedDraftfans
Oxidation aircompressor
Pulverizers, crushers &Coal millsBoil feed water pump
Forced draft, primary air& secondary air fans
ww
w.m
atri
x-in
dust
ries
.com
Boiler Feed water Pumps
Tandem Train Rated 6700 kW*2
Parameter Description
Power rating 3,000 to 22,380 kW
Pole number 2 or 4
Voltage level 3.3 to 13.8 kV
Installation Indoor
Assembly Single or Tandem Train (Coupling by TECO between Motors)
TECO’s accomplishment
4 Pole 20,500kW for LUENEN, GERMANY.
ww
w.m
atri
x-in
dust
ries
.com
Induced Draft Fan
Parameter Description
Power rating 3,000 to 10,000 kW
Pole number 8 to 14
Voltage level 6.0 to 13.8 kV
Installation Outdoor
Features - Sleeve Bearing(Common System Lubrication from Fan Bearings)- High Inertia (3X + NEMA)
TECO’s accomplishment
8/10 Pole, 9373/4905 kW for FORMOSA, TAIWAN
ww
w.m
atri
x-in
dust
ries
.com
5200 kW, 22 Pole
Circulating Water Pumps
Parameter Description
Power rating 2,500 to 6,500 kW
Pole number 16 to 32
Voltage level 4.0 to 13.8 kV
Installation Outdoor
Features - Plate Type Thrust Bearing - Oil Lubricated Lower Bearing- Surge Capacitor, LightningArrestors, and PD Monitoring
TECO’s accomplishment
22 Pole, 5200kW for TEXAS Utility, U.S.A
ww
w.m
atri
x-in
dust
ries
.com
Forced Draft Fan
Parameter Description
Power rating (kW) 750 to 3,500
Pole number 4 to 8
Voltage level (kV) Generally Medium Voltage, 3.3 kV to 13.8 kV
Installation Indoor or Outdoor
Features - Across the Line Starting- Sleeve Bearing- 2 x NEMA High Inertia
TECO’s accomplishment
8 Pole 3330kW for MHI, JAPAN.
ww
w.m
atri
x-in
dust
ries
.com
Coal Pulverizer
Parameter Description
Power rating 350 to 1,500 kW
Pole number 6 to 10
Voltage level Generally Medium Voltage, 3.3 kV to 13.8 kV
Installation Indoor or Outdoor
Features - High Torque Design, 200-250% Locked Torque at 80% Voltage- May Use Clutch at Times- KVA/ Hp, Code G or Code H- Bi Direction to Even the Wear on the Pulverizer
TECO’s accomplishment
8 Pole 1150kW for MHI JAPAN
ww
w.m
atri
x-in
dust
ries
.com
Squirrel Cage Horizontal
Power (kW) 650Voltage (V) 6600
Pole 10Cooling TEAAC
Mounting IM B3Starting Method DOL
Efficiency 95.5 %
CW Pump Motor replacement Combined-cycle power plant (EGT-Alsthom)
ww
w.m
atri
x-in
dust
ries
.com
Existing motor Siemens
Replacement reason
- Problem in cooling system - high operation temperature
Challenges - The motor most be the same as existed motor functionality due to parallel application(same parameter such as RPM, Efficiency, . . .)
- Dimensional limits- Foundation limits- Cooling system upgrade
from IC511 to IC611
Replacement of SIEMENS-Parallel CW Pump
Existing Motor
TECO Westinghouse
ww
w.m
atri
x-in
dust
ries
.com
Site visit after successful replacementParallel CW Pumps output (flow)
ww
w.m
atri
x-in
dust
ries
.com
Squirrel Cage HorizontalPower (HP) 1000Voltage (V) 2300
Pole 4Cooling IC01 (WPII)
Mounting IM B3Starting Method DOL
Efficiency 95.2 %
Replacement of 1000HP motor (GE) for FD-FanThermal Power plant
ww
w.m
atri
x-in
dust
ries
.com
Replacement of 1000HP motor (GE) for FD-FanThermal Power plant
ww
w.m
atri
x-in
dust
ries
.com
Squirrel Cage Induction Motor
Power (kW) 450
Voltage (V) 6600Frequency (Hz) 50
IP 55IC 411
Mounting B3
TECO-Westinghouse (Main & Spare) MotorNatural Gas Power plant
ww
w.m
atri
x-in
dust
ries
.com
TECO-Westinghouse (Main & Spare) MotorWitnessed Full Load Test With dynamometer In TECO Company