power distribution unit

1
POWER DISTRIBUTION UNIT POWER DISTRIBUTION UNIT AWC-PDU Series 19” wide, 1U Design Supports 1-6 TMAs 20-60V DC, positive or negative Modular and compact AWC-PDU-2 : Supports 1 sector AWC-PDU-4 : Supports 2 sectors AWC-PDU-6 : Supports 3 sectors Benefits Wide range of input voltage, +ve, or -ve High degree of lightning protection Modular – each module support 2 TMA’s Easy to upgrade for site expansion Ultra compact design Specifications Electrical Input Voltage 20-60V, positive or negative Max. Input Current 1A Output Voltage 12V DC +/-1 V (15V DC optional) Max. Output Current 375mA/TMA port Output Protection Automatic short circuit protection Alarm Output Relay NO and NC Mechanical Size 19” x 3.7” x 1.725” Weight 0.4lbs Material Aluminum Finish Brushed Input Voltage Connector 3 pin Molex Alarm Output Connector 3 pin Molex Output Voltage Connector 3 pin Molex Output Voltage LED Steady Green : OK Output Port Current LED Steady Green : OK Flashing Green : Minor Alarm Steady Off : Major Alarm Westell-Antone 720 Avenue F, Suite 106 Plano, TX 75074 USA Tel : 972-423-1666 www.westell.com Function Supplies power to TMA Interprets alarm states, and forwards to main BTS alarm Provides additional lightning protection 1211iArB

Upload: iehor-biss

Post on 27-Jan-2016

216 views

Category:

Documents


1 download

DESCRIPTION

Westell Antone PDU datasheet

TRANSCRIPT

Page 1: POWER DISTRIBUTION UNIT

POWER DISTRIBUTION UNITPOWER DISTRIBUTION UNIT

AWC-PDU Series

19”

wide, 1U Design

Supports 1-6 TMAs

20-60V DC, positive or negative

Modular and compact

AWC-PDU-2: Supports 1 sector

AWC-PDU-4: Supports 2 sectors

AWC-PDU-6: Supports 3

sectors

Benefits

Wide range of input voltage, +ve, or -ve

High degree of lightning protection

Modular –

each module support 2 TMA’s

Easy to upgrade for site expansion

Ultra compact design

Specifications

ElectricalInput Voltage

20-60V, positive or negative Max. Input Current

1AOutput Voltage

12V DC +/-1 V (15V DC optional)Max. Output Current

375mA/TMA portOutput Protection

Automatic short circuit protectionAlarm Output

Relay NO and NC

MechanicalSize

19”

x 3.7”

x 1.725”Weight

0.4lbsMaterial

AluminumFinish

BrushedInput Voltage Connector

3 pin MolexAlarm Output Connector

3 pin MolexOutput Voltage Connector

3 pin MolexOutput Voltage LED

Steady Green : OKOutput Port Current LED

Steady Green : OKFlashing Green : Minor AlarmSteady Off : Major Alarm

Westell-Antone720 Avenue F, Suite 106Plano, TX 75074 USA

Tel : 972-423-1666

www.westell.com

Function

Supplies power to TMA

Interprets alarm states, and forwards to main BTS alarm

Provides additional lightning protection

1211iArB