pom
DESCRIPTION
POMTRANSCRIPT
![Page 1: Pom](https://reader036.vdocuments.us/reader036/viewer/2022082715/5695d2111a28ab9b0298f828/html5/thumbnails/1.jpg)
POM-checkup04/21/04
For further Documentation please see drawings AOK-1xxAnd Assembly Drawing AOK-100-1 and-2
![Page 2: Pom](https://reader036.vdocuments.us/reader036/viewer/2022082715/5695d2111a28ab9b0298f828/html5/thumbnails/2.jpg)
BendixPivot2 per GimbalFrame
ActuatorCounterSpring
The function of this Actuator Counter Spring is to preload the Inner Gimbal Frame against the Actuator. In a situation where this spring is not making contact with the Inner Gimbal Frame, we might see the oscillations that were reported in the troublelog on04/21/04.
Inner Gimbal Frame
Outer Gimbal FramePickoffMirrorClipQty=3
![Page 3: Pom](https://reader036.vdocuments.us/reader036/viewer/2022082715/5695d2111a28ab9b0298f828/html5/thumbnails/3.jpg)
OuterGimbalHard Stop
Inner GimbalHard Stop
The 2 Hard Stops shown here prevent the two Gimbal Frames from overtravel.
Actuator
![Page 4: Pom](https://reader036.vdocuments.us/reader036/viewer/2022082715/5695d2111a28ab9b0298f828/html5/thumbnails/4.jpg)
This is how the Outer Gimbal Frame is preloaded against the Actuator.
PlungerBrass(preloadedwith spring)
Actuator is not shownIn right position!!
Bendix Pivot
Actuator Tipwill touch this button when inoperation