point-fixed glass wall fitting typical product catalog160p

155
bëí~ÄäáëÜÉÇ=áå=NVTR HONGKONG KINLONG CONSTRUCTION HARDWARE(GROUP)CO.,LTD. http://www.kinlong.com ADD: No.1 Xizibian Rd, Tanxia Town, DongGuan City, GuangDong province, China. Zip code:523722 Tel: +86-769-87943133 87943668 +86-13827420353 Fax: +86-769-87942388 +86-769-87943188 E-mail: [email protected] [email protected] HONGKONG KINLONG CONSTRUCTION HARDWARE(GROUP)CO.,LTD. POINT-FIXED GLASS WALL FITTINGS 2006 VERSION TYPICAL PRODUCT CATALOG ^ää=êáÖÜíë=êÉëÉêîÉÇK KIN LONG POINT-FIXED GLASS WALL FITTINGS TYPICAL PROOUCT CATALOG 2006 VERSION ® !"#$% ® !"#$%

Upload: najib-kiwan

Post on 28-Apr-2015

220 views

Category:

Documents


26 download

TRANSCRIPT

Page 1: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

bëí~ÄäáëÜÉÇ=áå=NVTR

HONGKONG KINLONG CONSTRUCTION

HARDWARE(GROUP)CO.,LTD.

http://www.kinlong.com

ADD: No.1 Xizibian Rd, Tanxia Town, DongGuan City, GuangDong

province, China.

Zip code:523722

Tel: +86-769-87943133 87943668 +86-13827420353

Fax: +86-769-87942388 +86-769-87943188

E-mail: [email protected] [email protected]

HONGKONG KINLONG CONSTRUCTION HARDWARE(GROUP)CO.,LTD.

POINT-FIXED GLASS WALL FITTINGS

2006 VERSION

TYPICAL PRODUCT CATALOG

^ää=êáÖÜíë=êÉëÉêîÉÇK

KIN

LON

G PO

INT-FIXED

GLA

SS WA

LL FITTING

S TYPICA

L PRO

OU

CT C

ATALO

G2006 VER

SION

��®

� � ! " # $ %

��®

� � ! " # $ %

Page 2: Point-Fixed Glass Wall Fitting Typical Product Catalog160P
Page 3: Point-Fixed Glass Wall Fitting Typical Product Catalog160P
Page 4: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

UNIQUE VALUE CAN ONLY BE CREATED BY

PROFESSIONALISM, SPECULATION HAS NO FUTURE

Page 5: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

Content

1� Company profile ............................................................................. 5 ~ 6

2� Surface finish of spider ................................................................... 7 ~ 8

3� Technical parameters of products .................................................. 9 ~16

4� Routel Flat cap routel ......................................................... 17 ~ 20

Countersunk routel ................................................. 21~ 23

Splice routel ............................................................ 25 ~ 26

5� Glass drilling and aluminum sleeve of IGU .................................... 24

6� Connector ....................................................................................... 27 ~ 30

7� Spider Spider fixed at centre ............................................. 31 ~ 78

Glass fin spider ....................................................... 79 ~ 93

8� Glass clamp.................................................................................... 94 ~ 102

9� Glass splice plates ......................................................................... 103 ~ 108

10� Spring spider and glass suspension clamp .................................... 109 ~ 110

11� Canopy fitting ................................................................................. 111 ~ 112

12� Fitting for openable window in glass wall ....................................... 113 ~ 116

13� Tension rod system ........................................................................ 117 ~ 124

14� Tension cable system..................................................................... 125 ~ 140

15� Swaged end of tension cable ......................................................... 141 ~ 143

16� Cable tension adjuster.................................................................... 144

17� Cable tension monitor system ........................................................ 145 ~ 146

18� Cable ergometer............................................................................. 147

19� Cable tension assurance device (temperature compensation) ...... 148

20� Cable tension overload protection device ...................................... 149

21� Spanner�Allen screw driver .......................................................... 150

Page 6: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

KINLONG PRODUCT LINE

1

Page 7: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

2

Page 8: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

3

Page 9: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

4

Page 10: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

Since 1975, Hong Kong Kinlong Construction Hardware(Group)Co. Ltd., has been an innovative and

professional company engaged in research, development and manufacture of fittings for point-fixed glass facades

and hardware for doors and windows. The company supplies fittings of best quality and provides consulting services

to the facade industry.

Unique values can only be created by professionalism, and speculation has no future. This motto is practiced

by HongKong Kinlong personnel at all levels in the company, in the continuous quest for constant technology

development, higher product quality, and better customer services. Today, the company has becoming prominent

and the largest supplier of fittings for point-fixed glass facades in the world.

Hongkong Kinlong has a factory of 130,000sq.m.with a construction area of 45,000sq.m.in DongGuan,

GuangDong, China. The company has more than 40 sales offices all over China, with headquarter located in

DongGuan and regional offices in Beijing and Shanghai. The company supplies fittings to more than 50% of the point-

fixed glass facade market in China in 2005. Point-fixed fittings are also exported to European, American and other

Asian countries. The total number of employees of the company exceeds 1200 in 2005.

5

Page 11: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

6

Striving to become the leader to serve the point -fixed glass facade industry in the world, HongKong Kinlong not

only adopts modern management and manufacturing method, but also invests heavily in design and innovation. The

company has achieved acclaim in innovative design, elegant appearance, best quality of its products and

unsurpassed services. HongKong Kinlong takes pride in supplying fittings to many famous signature buildings in

countless cities all over the world.

Hongkong Kinlong maintains its leadership in the industry with unswerving energy and efforts, looking into the

future while examining the past, to face the challenges of developing times and to meet the ever-changing needs.

Kinlong is your best and most reliable partner in the supply of fittings for point-fixed glass facade systems, and

hardware for door and windows.

Page 12: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

Mirror

Satin

Pearl sand finish

Finish to stainless

steel spiders

7

Page 13: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

Flurocarbon coated stainless

steel spiders

1): A wide vareties of color is available

2): Flurocarbon coating finish has superior weathering and corrosion resistance characeristics,

hence, is recommended to use in heavily-polluted and/or marine environment.

8

Page 14: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

Typical spider system assembly (welded to steel structure)9

Routel assembly

ConnectorAssembly

Spider

Page 15: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

Reference design load of routel (Material S.S. 316)

Routel name Design axial load capability, N*(Negative windload)

Design radial load capability, N*(Dead - Weight)

LNo.

HTF11�HTF13

HTF12

HTF14

HTF21�HTF22�HTF23

HTF31

HTF41

HTF42

HTF43

HTF51

HTF81

HTF82

HTF83

HTF84

HTC11

HTC12

HTC13

HTC14

HTC21

HTC42

HTC43

HTC81

HTC82

HTJ11�HTJ12�HTJ13

HTJ15�HTJ16�HTJ25

HTJ21�HTJ23

4500

4500

4500

4500

6000

6000

4500

4500

6000

2500

2500

4500

4500

4500

4500

4500

4500

6000

4500

4500

2500

2500

6000

6000

6000

60

62

68

60

82

81

65

57

65

55

42

45

40

64

59

64

55

82

74

63

54

42

73-93

59-77

73-93

2000

2000

1600

2000

2500

2500

2000

2000

2500

1200

1200

2000

2000

2000

2000

2000

2000

2500

2000

2000

1200

1200

2500

2000

2500

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

10

When length L or any design lod exceeds the value indicated in the above table, the

designer should verify the strength of the head bolt based on the design loading conditions

* Design values shown in the table are considered acceptable in China, and may not be adequate to fulfill acceptance criteria in other countries.

For more stringent requirements, it is suggested to multiply the values in the table with a factor of 0.8. It would be even better for the designer

user to test for adequacy against relevant national standard before use. See also disclaimer on page 150.

Page 16: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

11

Reference design load of spider (Material S.S. 316)

Spider nameNo. Design axial load capability of single arm

N* (Negative windload)

Design radial load capability of single arm

N* (Dead load)

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

H130A

H160A

H160C

H160D

H160E

H200A

H200B

H200C

H210A

H220A

H220B

H220C

HS220D

H250A

H250BA

H250BB

H250BC

H250BD

H250BE

H250BF

H250C

H250D

H250E

H250F

H250G

H250H

H250R

H250K

H250L

H250M

HS250A

H300A

H300B

H300C

4000

1500

1500

1500

1500

2000

1500

2000

3000

2800

2200

3500

3800

3000

2500

2500

2000

4500

3500

2500

3300

4300

3300

2500

3000

4800

3000

4000

3000

5000

5000

6000

6300

6000

1000

1000

1000

1000

1000

1200

1200

1200

1500

1500

1200

2000

2000

2000

2000

2000

1200

2000

1200

2000

2000

2000

1200

2000

2000

2000

2000

2000

2000

2500

2000

2000

2000

2500

* Design values shown in the table are considered acceptable in China, and may not be adequate to fulfill acceptance criteria in other countries.

For more stringent requirements, it is suggested to multiply the values in the table with a factor of 0.8. It would be even better for the designer

user to test for adequacy against relevant national standard before use. See also disclaimer on page 150.

Page 17: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

12

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

H300D

H300E

H300G

H2540A

H3040A

H3060A

H3060B

H3070A

H4706K

H4706G

H2542T

HJ3030T

H3535T

H3060T

HL210A

HL220A

HL220B

HL220C

HL250A

HL250B

HL250C

HL250D

HL250E

HL250F

HL250G

HL250H

HL265A

HL265B

HL300A

HL300B

HL300C

HL300D

HL300E

HL300F

3000

5000

3500

6500

2500

3500

6500

6500

4000

4000

4000

5000

2500

3000

2000

4500

4500

4500

3800

4000

2200

4000

2300

3300

5000

4000

5500

5500

3500

3500

3500

3500

3500

3500

2000

2000

1200

2000

1500

2000

2500

2500

2000

2000

2000

2000

1500

2000

1000

2000

2000

2000

2000

2000

1200

2000

1500

1500

2000

2000

2500

2500

----

1500

1500

1500

-----

-----

Spider nameNo. Design axial load capability of single arm

N* (Negative windload)

Design radial load capability of single arm

N* (Dead load)

* Design values shown in the table are considered acceptable in China, and may not be adequate to fulfill acceptance criteria in other countries.

For more stringent requirements, it is suggested to multiply the values in the table with a factor of 0.8. It would be even better for the designer

user to test for adequacy against relevant national standard before use. See also disclaimer on page 150.

Page 18: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

13

Reference design load of Glass Clamp (Material S.S. 316)

Clamp nameDesign axial load capability, N*

(Negative windload)Design radial load capability, N*

(Dead load)No.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

30000

30000

24000

24000

24000

20000

20000

24000

24000

24000

20000

20000

20000

20000

24000

24000

24000

20000

26000

24000

24000

7000

7000

7000

7000

7000

5000

5000

3500

3000

3000

2000

2000

3500

3500

3000

3000

3000

3000

5000

3000

3000

HJ307S

HJ307G

HJ308S

HJ308Z

HJ308L

HJ288K

HJ257G

HJ159K

HJ120G

HJ120S

HJI45KX

HJ145KH

HJ15OS

HJ15OL

HJ200K1

HJ200K2

HJ200K3

HJ152S1

HJ152S2

HJ170S

HJ2213S

* Design values shown in the table are considered acceptable in China, and may not be adequate to fulfill acceptance criteria in other countries.

For more stringent requirements, it is suggested to multiply the values in the table with a factor of 0.8. It would be even better for the designer

user to test for adequacy against relevant national standard before use. See also disclaimer on page 150.

Page 19: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

14

Design load capability of glass suspension clamp (Material Q 235B)

No. Glass Suspension Clamp Name Design load capability, N*

1 HDY11 4000

2 HDY11B 4000

3 HDY21B 4000

4 HDY12 7000

5 HDY22 7000

* Design values shown in the table are considered acceptable in China, and may not be adequate to fulfill

acceptance criteria in other countries.For more stringent requirements, it is suggested to multiply the values in the

table with a factor of 0.8. It would be even better for the designer user to test for adequacy against relevant national

standard before use. See also disclaimer on page 150.

Page 20: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

Cross-sectional areas of tension rods and mechanical properties(Type A Standard thread) Materials : stainless steel 316

Note: In accordance with Chinese statutory regulation JGJ102-2003, Maximum design load = tensile strength / 1.4 . However, the designer

should use a design load with selected safety factor in compliance with the local government regulations in the respective country. See also

disclaimer on page 150.

Elongation �,%No. Rod diameter, mm Effective sectionarea of rod, mm2

Cross-sectional areaof rod, mm2

Yield Strength�

0.2, MPa

Tensile Strength�

b, MPa

1 Ø8 36.608 50.265

2 Ø10 57.989 78.540

3 Ø12 84.266 113.097

4 Ø14 115.44 153.938

5 Ø16 156.668 201.062

6 Ø18 192.472 254.469

7 Ø20 244.794 314.159 250 625 ≥20

8 Ø22 303.399 380.133

9 Ø25 386.567 490.874

10 Ø28 498.182 615.752

11 Ø30 560.587 706.858

12 Ø32 647.660 804.248

13 Ø36 816.722 1017.876

Elongation �,%No. Rod diameter, mm Effective sectionarea of rod, mm2

Cross-sectional areaof rod, mm2

Yield Strength�

0.2, MPa

Tensile Strength�

b, MPa

(Type B Non-standard thread) Materials : stainless steel 316

15

1 Ø8 50.265 50.265

2 Ø10 78.540 78.540

3 Ø12 113.097 113.097

4 Ø14 153.938 153.938

5 Ø16 201.062 201.062 250 625 ≥20

6 Ø18 254.469 254.469

7 Ø20 314.159 314.159

8 Ø22 380.133 380.133

9 Ø25 490.874 490.874

Note: In accordance with Chinese statutory regulation JGJ102-2003, Maximum design load = tensile strength / 1.4 . However, the designer

should use a design load with selected safety factor in compliance with the local government regulations in the respective country. See also

disclaimer on page 150.

Page 21: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

S.S 316 cable section area and mechanical properties

1250

1200

16

Cablestructure

Cable Diameter Wire Diameter Cable section area Wire breaking strength Breaking Strength Modules Elasticity

(mm) (mm) (mm2) (N/mm2) (KN) (105MPa)

6.0 1.2 21.49 25.53

8.0 1.6 38.20 45.37

1 x 19 10.0 2.0 59.69 70.90 0.9 ~ 1.25

12.0 2.4 85.95 102.10

14.0 2.8 116.99 138.97

16.0 3.2 152.81 181.52

18.0 2.6 192.15 220.39

1 x 37 19.5 2.8 225.51 255.60

21.0 3.0 261.54 1320 293.43

22.5 2.5 299.43 309.76

1 x 61 24.0 2.7 340.69 363.55

26.0 2.9 399.84 421.66 1.25 ~ 1.45

28.0 3.1 463.72 484.0

30.0 2.7 531.60 542.34

1 x 91 32.0 2.9 604.85 628.98

34.0 3.1 682.82 722.04

36.0 3.3 765.51 821.53

38.0 3.5 853.15 964.91

40.0 3.6 945.07 1300 1068.87

42.0 3.8 1041.94 1178.43

44.0 4.0 1143.54 1243.60

46.0 4.2 1249.86 1359.22

48.0 4.4 1360.92 1420.80

50.0 4.5 1476.38 1541.34

Note: In accordance with Chinese statutory regulation JGJ102-2003, Maximum design load = minimum breaking strength / 1.8 . However, the

designer should use a design load with selected safety factor in compliance with the local government regulations in the respective country. See

also disclaimer on page 150.

Page 22: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

17

Flat cap routel

HTF11 (Previous Model: HT02)

HTF12 (Previous Model:HT02B)

HTF13 (Previous Model:HT02C)

HTF14 (Previous Model: HT02D)

Page 23: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

18

Flat cap routel

HTF21 (Previous Model: HT02E)

HTF22 (Previous Model: HT02F)

HTF23 (Previous Model: HT02G)

HTF31 (Previous Model: HT03)

Page 24: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

19

HTF41 (thermal insulated)

(Previous Model: HT04)

HTF42 (Previous Model: HT11A)

HTF43

HTF51 (Previous Model: HT10)

Flat cap routel

Page 25: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

20

HTF81 (Previous Model: HT06A)

HTF82 (Previous Model: HT16A)

HTF83 (Previous Model: HT07A)

HTF84 (Previous Model: HT17)

Flat cap routel

Page 26: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

21

HTC11 (Previous Model: HT01)

HTC12 (Previous Model: HT01B)

HTC13 (Previous Model: HT01C)

HTC14 (Previous Model: HT14A)

Countersunk routel

Page 27: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

22

HTC21 (Previous Model: HT08)

HTC42 (Previous Model: HT12B)

HTC43

HTC81 (Previous Model: HT13)

Countersunk routel

Page 28: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

23

HTC82 (Previous Model: HT15A)

Countersunk Routel

Applicable: HTC11~HTC13�HTC42�HTC43 Applicable: HTC11~HTC13�HTC42�HTC43

Applicable: HTC21Applicable: HTC14

Applicable: HTC82Applicable: HTC81

Page 29: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

24

Al. sleeve for IGU

Glass Drilling

Applicable: HTF31�HTF41 Applicable: HTF31�HTF41

Applicable: HTF11~HTF14�HTF21~HTF23�HTF42�HTF43 Applicable: HTF84

Applicable: HTF82�HTF83

Applicable: HTF51 Applicable: HTF81

Applicable: HTF11~HTF14�HTF21~HTF23�HTF42�HTF43

Page 30: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

25

HTJ11 (Previous Model: HJ03C)

HTJ12 (thermal insulated)

HTJ13 (Previous Model: HJ01C)

HTJ15 (Previous Model: HJ02C)

Splice routel

Page 31: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

26

HTJ16 (thermal insulated)

HTJ 21

HTJ 23

HTJ 25

Splice routel

Page 32: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

27

HZ11

HZ14(Previous Model: HZ01L)

HZ15(Previous Model: HZ01L)

HZ16(Previous Model: HZ01M)

Connector

Page 33: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

28

HZ24(Previous Model: HZ01P)

HZ25(Previous Model: HZ01P)

HZ26(Previous Model: HZ01P)

HZ31

Connector

Page 34: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

29

HZ34(Previous Model: HZ05)

HZ35(Previous Model: HZ05)

HZ36(Previous Model: HZ05A)

HZ38(Previous Model: HZ02C)

Connector

Page 35: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

30

HZ15B

HZ44(Previous Model: HZ01J)

HZ61(Previous Model: HSJ-7A)

Connector

HZ42(Previous Model: HZ01H)

HZ11�HZ44: Unless specified,the base of HZ11�HZ44 will bemade of carbon steel Q235. If stain-less steel is required, please addsuffix “B” to the model. For example,the base of the connector HZ15B inthe left photo is made of stainlesssteel.

Page 36: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H250A11 H250A12 H250A13

H250A21

H250A22 H250A23H250A24

H250A31 H250A32 H250A33

H250A

31

H220C H250D

Page 37: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H220C14 H250A15 H250A16

H250A25 H250A26

H250A34

32

Codification method of KIN LONG X- and H-shaped spiders

Note: If the elliptic hole needs to be 17 x 26 to accommodate

M16 bolt, �*�needs to be added behind the spider series code.

For example, the dimensions of the elliptic hole of 250A is 14.5 x 26

while the dimensions of the elliptic hole of 250A* is 17 x 26.

position of arm(s) as explained in photos below (omit if four-arm)

Number of arms (omit if four arm)

Different spider series�A,B,C, ...etc.)

centre-to-centre span between adjacent arms

�S� indicates use in cable net, otherwise omit

�H� indicates product for export out of China

H

H250A27

Page 38: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H120A Series

33

H120A (Previous Model: H1201A)

H120A21 (Previous Model: H1202A)

Page 39: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H130A Series

34

H130A (Previous Model: H1301)

H130A21 (Previous Model: H1302)

Page 40: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H160A Series

35

H160A (Previous Model: H1601A)

H160A21 (Previous Model: H1602A)

Page 41: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H160C Series

36

H160C (Previous Model: H1601C)

H160C21 (Previous Model: H1602C)

Page 42: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H160D Series

37

H160D (Previous Model: H1601D)

H160D21 (Previous Model: H1602D)

Page 43: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H160E Series

38

H160E (Previous Model: H1601E)

H160E21 (Previous Model: H1602E)

Page 44: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H200A Series

39

H200A (Previous Model: H2001A)

H200A21 (Previous Model: H2002A)

Page 45: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H200B Series

40

H200B (Previous Model: H2001B)

H200B21 (Previous Model: H2002B)

Page 46: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H200C Series

41

H200C (Previous Model: H2001C)

H200CA21 (Previous Model: H2002C)

Page 47: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H210A Series

42

H210A (Previous Model: H2101)

H210A21 (Previous Model: H2102)

Page 48: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H220A Series

43

H220A (Previous Model: H2201E)

H220A21 (Previous Model: H2202E)

Page 49: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H220B Series

44

H220B (Previous Model: H2201B)

H220B21 (Previous Model: H2202B)

Page 50: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H220C Series

45

H220C (Previous Model: H2207)

H220C21 (Previous Model: H2202)

Page 51: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

HS220A Series

HS220A 46

Page 52: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H250A Series

47

H250A (Previous Model: H2501T)

H250A21 (Previous Model: H2502T)

Page 53: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H250AA Series

H250AB Series

H250AA2148

H250AA22

H250AB22

H250AA (Previous Model: H2509)

H250AB (Previous Model: H2511)

H250AB21 (Previous Model: H2512)

Page 54: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H250AC Series

H250AD Series

49

H250AC

H250AC21

H250AC22

H250AD22

H250AD (Previous Model: H2513)

H250AD21 (Previous Model: H2514)

Page 55: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H250AE Series

50

H250AE22

H250AE23

H250AE24

H250AE (Previous Model: H2515)

H250AE21 (Previous Model: H2516)

Page 56: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H250BA Series

51

H250BA (Previous Model: H2501B)

H250BA21 (Previous Model: H2502B)

Page 57: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H250BB Series

52

H250BB21

H250BB (Previous Model: H2504B)

Page 58: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H250BC Series

H250BD Series

53

H250BC (Previous Model: H250BF)

H250BD (Previous Model: H2505B)

Page 59: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H250BE Series

H250BF Series

54

H250BE (Previous Model: H2506B)

H250BE21 (Previous Model: H2507B)

H250BF (Previous Model: HW2501)

Page 60: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H250C Series

55

H250C (Previous Model: H2501C)

H250C21 (Previous Model: H2502C)

Page 61: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H250D Series

56

H250D (Previous Model: H2501D)

H250D23 (Previous Model: H2502D)

H250D31 (Previous Model: H2505D)

H250D32 (Previous Model: H2506D)

Page 62: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H250E Series

57

H250E (Previous Model: H2501E)

Page 63: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H250F Series

58

H250F (Previous Model: H2501S)

Page 64: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H250G Series

59

H250G (Previous Model: H2501F)

H250G22

Page 65: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H250H Series

60

H250H (Previous Model: H2501H)

H250H21 (Previous Model: H2502H)

Page 66: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H250K Series

61

H250K (Previous Model: H2501K)

H250K21 (Previous Model: H2502K)

Page 67: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H250L Series

62

H250L (Previous Model: H2501L)

H250L21 (Previous Model: H2502L)

Page 68: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H250R Series

63

H250R (Previous Model: H2501R)

Page 69: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

HS250A Series

64

HS250A (Previous Model: HSZ250A)

HS250A21 (Previous Model: HSZ2502)

Page 70: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H300A Series

65

H300A (Previous Model: H3001)

H300A21 (Previous Model: H3002)

Page 71: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H300B Series

66

H300B (Previous Model: H3001B)

H300B21 (Previous Model: H3002B)

Page 72: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H300C Series

67

H300C (Previous Model: H3001C)

H300C21 (Previous Model: H3002C)

Page 73: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H300D Series

68

H300D (Previous Model: H3001D)

H300A21 (Previous Model: H3002)

Page 74: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H300E Series

69H300E21

H300E (Previous Model: H3001Y)

Page 75: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H300G Series

70

H300G (Previous Model: H3001A)

H300G23 (Previous Model: H3002A)

H300G01 (Previous Model: H3003A)

Spider

Moder:H300G23

Connector

Page 76: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H2540A Series

71

H2540A (Previous Model: H2541A)

Page 77: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H3040A Series

72

H3040A (Previous Model: H3041A)

Page 78: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H3060A Series

73

H3060A23

H3060A24 H3060A*24

H3060A25 H3060A*25

H3060A (Previous Model: H3061)

H3060A26 H3060A*26

(Previous Model: H3062)

Page 79: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H3060B Series

74

H3060B (Previous Model: H3061B)

H3060B21 (Previous Model: H3062B)

Page 80: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H3070A Series

75

H4706 Series

H3070A (Previous Model: H30701)

H3070A21 (Previous Model: H30702)

H4706K (Previous Model: HW3001)

H4706G

Page 81: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H2542T Series

76

H2542T (Previous Model: H2541)

Page 82: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

HJ3030T Series

H3535T Series

77

HJ3030T (Previous Model:H3001E)

H3535T (Previous Model: H2501Q)

Page 83: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

H3060T Series

78

H3060T (Previous Model: H3061E)

Page 84: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

HL210A1

HL210A2

HL210A3

HL210A5

HL210A4

HL210A6

HL210A7

(Previous Model: HQ2102a)

79

Page 85: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

80

HL220A1 (Previous Model: HL01)

HL220A2 (Previous Model:HL02)

HL220A3 (Previous Model: HL04)

HL220A5 (Previous Model: HL07)

HL220A4 (Previous Model:HL08)

HL220A6 (Previous Model:HL03)

Page 86: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

81HL220B2 (Previous Model: HL15)

HL220B1 (Previous Model: HL14)

HL220B3 (Previous Model: HL19) HL220B4 (Previous Model: HL18)

HL220B5 (Previous Model: HL16) HL220B6 (Previous Model: HL17)

Page 87: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

HL220C1

HL220C2

HL220C3 HL220C4

HL220C5HL220C6

82

Page 88: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

83

HL250A2 (Previous Model: HL2502A-F)

HL250A1 (Previous Model: HL2501A-F)

HL250A3 (Previous Model: HL2503A-F) HL250A4 (Previous Model: HL2504A-F)

HL250A5 (Previous Model: HL2506A-F) HL250A6 (Previous Model: HL2505A-F)

Page 89: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

HL250B2 (Previous Model: HL2501)84

HL250B1 (Previous Model: HL2502)

HL250B3 (Previous Model: HL2507)

HL250B7

(Previous Model: HL2503)HL250B4

(Previous Model: HL2508)

HL250B5 (Previous Model: HL2506) HL250B6 (Previous Model: HL2505)

Page 90: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

HL250C1

HL250C3 HL250C4

HL250C5 HL250C6

85HL250C2 (Previous Model: HL2504)

Page 91: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

86

HL250D1 (Previous Model: HL2510)

HL250D2 (Previous Model: HL2509)

HL250E1 (Previous Model: HL2503C)

HL250E7 (Previous Model: HL2501C)

Page 92: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

87

HL250F1 (Previous Model: HL2501D)

HL250G2 (Previous Model: HL2501E)

Splice routel

Glass fin HL250G2 HL250G2

Example of glass fin spider

Page 93: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

HL250H3 HL250H4

HL250H5 HL250H6

88

HL250H1

HL250H2

Page 94: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

89

HL265A1 (Previous Model: HL2651)

HL265A2 (Previous Model: HL2652)

HL265A3 (Previous Model: HL2653) HL265A4 (Previous Model: HL2655)

HL265A5 (Previous Model: HL2656) HL265A6 (Previous Model: HL2654)

Page 95: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

90

HL265B1 (Previous Model: HL2652B)

HL265B2 (Previous Model: HL2651B)

HL265B3 (Previous Model: HL2654B) HL265B4 (Previous Model: HL2653B)

HL265B5 (Previous Model: HL2656B) HL265B6 (Previous Model: HL2655B)

Page 96: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

91

HL300A (Previous Model: HL06A)

HL300B (Previous Model: HL06B)

HL300C (Previous Model: HL06C)

HL300CY (Previous Model: HL06D)

Page 97: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

92

HL300CN (Previous Model: HL06E)

HL300D (Previous Model: HL06F)

HL300E (Previous Model: HL06N)

HL300F (Previous Model: HL06W)

Page 98: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

93

HL300FY (Previous Model: HL-160)

Page 99: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

94

HJ307S (Previous Model: HJJ01A)

HJ307G (Previous Model: HJJ02A)

HJ308S (thermal insulated)(Previous Model: HJJ-7)

HSJ308Z (thermal insulated)(Previous Model: HJJ-6)

Page 100: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

95

HJ288K (Previous Model: HJJ-12)

HJ257G (Previous Model: HJJ-11)

HJ159K (Previous Model: HSJ-8A)

HJ308L (Previous Model: HL-J2)

Page 101: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

96

HJ120G11 (Previous Model: HSJ-1A)

HJ120G21 (Previous Model: HSJ-2A)

HJ120S11 (Previous Model: HSJ-3B)

HJ120S21 (Previous Model: HSJ-4A)

Page 102: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

97

HJ120S13

HJ120S23 (Previous Model: HSJ-6C)

HJ120S12 (Previous Model: HSJ-3C)

HJ120S22

Page 103: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

98

HJ120S14

HJ120S24 (Previous Model: HSJ-6B)

HJ120S15 (Thermal insulated)

HJ120S25 (Thermal insulated)

Page 104: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

99

HJ120S16 (Thermal insulated)

HJ120S26 (Thermal insulated)

HJ145KX (Previous Model: HSJ-21)

HJ145KH (Previous Model: HSJ-20)

Page 105: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

100

HJ150S (Previous Model: HSJ-11A)

HJ150L (Previous Model: HL-J1)

HJ200K1 (Previous Model: HSJ-5)

HJ200K2 (Previous Model: HSJ-5B)

Page 106: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

101

HJ200K3 (Previous Model: HSJ-5A)

HJ170S1 (Previous Model: HSJ-9A)

HJ152S1

HJ152S2

Page 107: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

102

HJ170S2 (Previous Model: HSJ-10A)

HJ170S3

HJ170S4

HJ2213S

Page 108: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

103

Page 109: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

104

HBL11 (Previous Model: HL340/HL340A)

HBL12 (Previous Model: HL340B)

Page 110: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

105

Glass fin suspension system

Glass Panel

glass fin spider

Glass fin suspension device

Tension rod

Glass fin suspension device

Glass fin

Page 111: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

106

HBL31 (Previous Model: HLC1)

HBL32 (Previous Model: HLC2)

HBL41 (Previous Model: HLD2)

HBL42 (Previous Model: HLD1)

Page 112: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

107

HBL55

Page 113: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

108

HBL51

HBL52

HBL53

HBL54

Page 114: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

109

HDT01 (Previous Model: HTH01)

The shape of DT01 is a product of its function

and anti-vibration, which is to transfer the load of

the glass and exerted to glass into the support

structure across the spring � fuse�(especially for

longer span glass glazing system). The V-geometry

HDY11 (Previous Model: HKLA)

Concealed glass suspension clamp

of the assembly divides the loads of the

glass weight into an oblique tension com-

ponent through the spring assembly and

into a horizontal compression compo-

nent through the compression strut or

body part of the assembly. The glass in

hung from this assembly by articulated

bolt. Generally speaking, the spring as-

sembly must remain fixed under loads of

up to 7.5kN; but when loads above the

threshold are applied, it must sag. The

more load exerted, the more sagging

deflection of the spring.

Spring Spider

Page 115: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

110

HDY11B (Previous Model: HKLA-a)

HDY12 (Previous Model: H2KLA)

HDY21B (Previous Model: HKLB)

HDY22 (Previous Model: H2KLB)

Page 116: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

111HYP11 (Previous Model: HYP-01)

HYP12 (Previous Model: HYP-04)

Page 117: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

112

HYP21 (Previous Model: HYP-02)

HYP22 (Previous Model: HYP-05)

HYP31 (Previous Model: HYP-03)

HYP32 (Previous Model: HYP-06)

Page 118: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

113

Page 119: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

114

Page 120: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

115

H250 31

H250 32

H250 33

H250 34

Page 121: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

116

Refeverce to our window-door catalog

Page 122: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

117

Note: Aforementioned support styles are typical, clients must choose

other support styles in accordance with unique project

Typical support styles to Cable support sytem

Page 123: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

118

Fishtail tension rod support system

Routel Strut Spider Tenion rod head

Page 124: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

119

Application Patch Fitting Elevation to Tension rod system

Page 125: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

120

Routel

H250 spider

tension Rod

Strut

Page 126: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

121

HGC50-1

HGC50-2

HGC50-3

HGC50-4

Page 127: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

122

HGC50-5

HSGP-01(Previous Model: HG10)

HSGP-02(Previous Model: HS05)

HSGP-03

Page 128: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

123

Tension rod head with diameter

less than 22mm (spring clamp pin)

Tension rod head with diameter above 22mm

L is the length you ordered (pin to pin)

Page 129: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

124

TYPE MODE D e f h1 h2 L1 d Single side adjustment

G01A-Ø12(10) Ø12 18 23 11 26.5 100 Ø13 ±12.5

G01A-Ø14 Ø14 20 25 13 31 108 Ø15 ±12.5

G01A-Ø16 Ø16 23 28 15 35 117 Ø16 ±12.5

G01A-Ø18 Ø18 25 35 17 40 130 Ø18 ±12.5

G01A-Ø20 Ø20 30 35 17 42.5 138 Ø20 ±14

G01A-Ø22 Ø22 32.5 42 21 47 148 Ø22 ±14

G01A-Ø25 Ø25 38 48 21 53 170 Ø24 ±15

G01A-Ø28 Ø28 42 52 25 60 182 Ø27 ±15

G01A-Ø30 Ø30 46 60 25 65 195 Ø30 ±15

G01A-Ø32 Ø32 49.5 65 27 68 205 Ø33 ±17.5

G01A-Ø36 Ø36 56.5 72 29 76 220 Ø37 ±17.5

Page 130: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

125

Typical support styles to Cable support sytem

Note: Aforementioned support styles are typical, clients must choose

other support styles in accordance with unique project

Page 131: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

126

Fishery cable support system

Turnbuckle

Fix Anchor

Spider Routel

Strut

Page 132: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

127

HSC65A

HSC75A

Page 133: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

128

HSC65B

HSC75B

Page 134: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

129

HSGP-04(Previous Model: HZC-1)

Page 135: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

130

L is the length you ordered (pin to pin)

Cable with diameter 10 & below 10, the anchor would be hex

Cable with diameter 12 & above 12, the anchor would be round

Page 136: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

D

Ø6

Ø8

Ø10

Ø12

Ø14

Ø16

Ø18

Ø19.5

Ø21

L1

≤ 370

≤ 430

≤ 495

≤ 558

≤ 615

≤ 680

≤ 775

≤ 795

≤ 860

L2

125

145

165

180

195

210

240

240

260

g

11

11

15

17

21

23

25

25

25

h1

30

30

35

44

52

58

62

62

70

h

38.5

38.5

45.5

53.5

60.5

68

80

80

84.5

d

15

15

16

20

22

28

31

31

34

e

19

19

24

26.5

31.5

36

43

43

45.5

f

28

28

28

33

35

42

50

50

60

131

Swaged end with adjustor

ModelW HB05

Page 137: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

D

Ø6

Ø8

Ø10

Ø12

Ø14

Ø16

Ø18

Ø19.5

Ø21

Ø22.5

Ø24

Ø26

Ø28

Ø30

Ø32

Ø34

Ø36

L1

≤ 370

≤ 430

≤ 495

≤ 558

≤ 615

≤ 680

≤ 775

≤ 795

≤ 860

≤ 895

≤ 945

≤ 1030

≤ 1090

≤ 1160

≤ 1235

≤ 1310

≤ 1380

L2

125

145

165

180

195

210

240

240

260

260

280

300

320

340

360

380

400

g

11

11

15

17

21

23

25

25

25

28

32

32

36

42

44

46

49

h1

30

30

35

44

52

58

62

62

70

72

78

82

94

105

110

120

128

h

38.5

38.5

45.5

53.5

60.5

68

80

80

84.5

89.5

94.5

103

109

117.5

126.5

134

141.5

d

15

15

16

20

22

28

31

31

34

36

37

41

45

49

53

56

59

e

19

19

24

26.5

31.5

36

43

43

45.5

48

51.5

55.5

59

62.5

68.5

73.5

76

f

28

28

28

33

35

42

50

50

60

60

60

70

72

75

80

88

95

132

Swaged end with adjustor

Model:HB05-E

Page 138: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

D

Ø6

Ø8

Ø10

Ø12

Ø14

Ø16

Ø18

Ø19.5

Ø21

L1

≤ 380

≤ 445

≤ 510

≤ 575

≤ 640

≤ 705

≤ 800

≤ 820

≤ 880

L2

125

145

165

180

195

210

240

240

260

e

18

20

23

30

35

40

38

38

40

h

36

40

46

60

70

80

76

76

80

d

13

15

17

19

23

28

31

31

34

k

10

12

14

16

20

22

28

28

28

133

Swaged end with adjustor

ModelWHB07

Page 139: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

D

Ø6

Ø8

Ø10

Ø12

Ø14

Ø16

Ø18

Ø19.5

Ø21

L1

≤ 430

≤ 500

≤ 570

≤ 645

≤ 725

≤ 800

≤ 900

≤ 920

≤ 990

L2

125

145

165

180

195

210

240

240

260

g

10

12

14

16

20

22

28

28

28

h1

22

24

26

32

40

46

52

52

56

h

40

44

50

60

70

80

84

84

92

d

13

15

16

18

22

28

31

31

34

e

20

22

25

30

35

40

42

42

46

f

30

33

37

40

50

55

60

60

68

134

Swaged end with adjustor

ModelWHB09

Page 140: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

D

Ø6

Ø8

Ø10

Ø12

Ø14

Ø16

Ø18

Ø19.5

Ø21

L1

≤ 425

≤ 495

≤ 570

≤ 650

≤ 730

≤ 800

≤ 900

≤ 920

≤ 985

L2

125

145

165

180

195

210

240

240

260

g

19

21

23

25

28

35

38

38

41

h

36

40

46

56

66

80

84

84

92

d

13

15

16

18

22

28

31

31

34

e

18

20

23

28

33

40

42

42

46

f

25

30

39

46

53

56

65

65

65

h1

31

33

39

41

48

59

62

62

69

135

Swaged end with adjustor

ModelWHB11

Page 141: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

g

11

11

15

17

21

23

25

25

25

28

32

32

36

42

44

46

49

h1

30

30

35

44

52

58

62

62

70

72

78

82

94

105

110

120

128

h

38.5

38.5

45.5

53.5

60.5

68

80

80

84.5

89.5

94.5

103

109

117.5

126.5

134

141.5

d

15

15

16

20

22

28

31

31

34

36

37

41

42

49

53

56

59

e

19

19

24

26.5

31.5

36

43

43

45.5

48

51.5

55.5

59

62.5

68.5

73.5

76

f

28

28

28

33

35

42

50

50

60

60

60

70

72

75

80

88

95

D

Ø6

Ø8

Ø10

Ø12

Ø14

Ø16

Ø18

Ø19.5

Ø21

Ø22.5

Ø24

Ø26

Ø28

Ø30

Ø32

Ø34

Ø36

L3

120

140

165

200

225

275

305

325

355

377

395

435

462

495

525

565

595

136

Swaged end

ModelWHD06

Page 142: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

D

Ø6

Ø8

Ø10

Ø12

Ø14

Ø16

Ø18

Ø19.5

Ø21

k

10

12

14

16

20

22

28

28

28

h

36

40

46

60

70

80

76

76

80

d

13

15

17

19

23

28

31

31

34

e

18

20

23

30

35

40

38

38

40

L3

130

155

180

220

250

300

330

350

375

137

Swaged end

ModelWHD01

Page 143: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

D

Ø6

Ø8

Ø10

Ø12

Ø14

Ø16

Ø18

Ø19.5

Ø21

L3

175

205

240

295

340

395

430

450

480

g

19

21

23

25

28

35

38

38

41

h1

31

33

39

41

48

59

62

62

69

h

36

40

46

56

66

80

84

84

92

d

13

15

16

18

22

28

31

31

34

e

18

20

23

28

33

40

42

42

46

f

25

30

39

46

53

56

65

65

65

138

Swaged end

ModelWHD02

Page 144: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

D

Ø6

Ø8

Ø10

Ø12

Ø14

Ø16

Ø18

Ø19.5

Ø21

L3

180

210

240

290

335

395

430

450

485

g

10

12

14

16

20

22

28

28

28

h1

22

24

26

32

40

46

52

52

56

h

40

44

50

60

70

80

84

84

92

d

13

15

16

18

22

28

31

31

34

e

20

22

25

30

35

40

42

42

46

f

30

33

37

40

50

55

60

60

68

139

Swaged end

ModelWHD0S3

Page 145: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

D

Ø6

Ø8

Ø10

Ø12

Ø14

Ø16

Ø18

Ø19.5

Ø21

L5

72

82

92

105

115

125

145

145

155

M

M33

M36

M39

M42

M45

M48

M52

M56

L4

145

175

205

240

270

315

355

375

400

M

M12

M14

M16

M20

M22

M27

M30

M30

M33

D

Ø22.5

Ø24

Ø26

Ø28

Ø30

Ø32

Ø34

Ø36

L5

155

160

175

185

192

208

215

230

L4

422

440

480

510

545

580

615

650

140

Swaged end

ModelWHE

Page 146: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

141

L1

≤930

≤952

≤970

≤986

≤1020

≤1020

≤1055

≤1070

≤1090

≤1130

≤1170

d

Ø50

Ø54

Ø58

Ø60

Ø62

Ø66

Ø68

Ø70

Ø72

Ø74

Ø76

g

54

56

58

65

68

70

72

74

76

78

80

D

Ø30

Ø32

Ø34

Ø36

Ø38

Ø40

Ø42

Ø44

Ø46

Ø48

Ø50

h1

104

106

112

121

124

130

134

136

142

146

150

e

55

57

62

65

72

75

78

81

83

85

87

f

98

102

108

110

115

120

130

130

140

150

160

h

102

108

118

124

132

138

146

152

156

160

164

Swaged end with adjustor

ModelWHG01

Page 147: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

142

L6

166

176

190

196

210

230

240

250

260

273

287

d

Ø50

Ø54

Ø58

Ø60

Ø62

Ø66

Ø68

Ø70

Ø72

Ø74

Ø76

g

54

56

58

65

68

70

72

74

76

78

80

D

Ø30

Ø32

Ø34

Ø36

Ø38

Ø40

Ø42

Ø44

Ø46

Ø48

Ø50

h1

104

106

112

121

124

130

134

136

142

146

150

e

55

57

62

65

72

75

78

81

83

85

87

f

68

72

78

80

87

92

100

100

108

117

130

h

102

108

118

124

132

138

146

152

156

160

164

Swaged end

ModelWHH01

Page 148: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

143

D

Ø30

Ø32

Ø34

Ø36

Ø38

Ø40

Ø42

Ø44

Ø46

Ø48

Ø50

L4

450

475

475

485

505

520

530

550

560

585

615

M

56

60

62

65

70

72

76

80

82

85

90

L5

225

233

233

236

243

248

248

252

252

255

270

Swaged end

ModelWHK01

Page 149: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

144

Property and selection of Cable tension facilitator

Series Model Max. tension load KN Applicable

1 HLSQ18 102 Ø14 ~ Ø19.5

2 HLSQ28 195 Ø18 ~ Ø28

3 HLSQ36 330 Ø30 ~ Ø36

It may be difficult to turn

the cable turnbuckle to in

crease or decrease cable ten-

sion during installation , es-

pecially when tension in the

cable is already high. It will

be much easier to turn the

cable turnbuckle if and when

a cssable tension facilitator

with pneumatic jack is used.

Page 150: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

145

Sampling device

Signal assembler

Page 151: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

146

The most transparent support system for a glass wall is the cable net system which is a typical flexible

stucture.For such support system,cables are always under appropriate tension to maintain the form of the

glass wall and the structure to be safe.Tensile forces in the cables are always affected by parameters like

the initial tension in the cables when the glass wall is erected,the temperature change of the environment,

and progressive creep in mateials under forces.It would be difficult to maintain cable tensile forces within

limits for a prolonged period without checking tension in the cable regularly.Hence,it would be desirable to

have a cable tension monitor system to constanly monitor tensile forces in the cables,and alert the concerned

party to take appropriate action when the tensile force in the cable is outside the designed range.

1:Diagram of the cable tension monitor system

CABLE TENSSION MONITOR SYSTEM

2: Components of Monitor System

(1)Sampling device

(2)Signal assembler

(3)Control display

3:Installstion of Monitor System

If a cable monitor system is used of a cable net system,the proper selection of cable monitors is

important to the success of the system. Cable monitors should be installed ideally for all major load

bearing cables,and selectively for minor or secondary load bearing cables provided safety is assured

with the chosen scheme.

Sampling device

Light and sound

alarm system Printer

Control display

Signal assembler

Page 152: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

147

Cable ergometer is a hand-held device divice that can provide real time

tensile force in the cable. During the process of adjusting cable tension,

force magnitude is shown dynamically on the display meter.

Cable ergometer

Page 153: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

148

Cable tension assurance

device device makes use of spring

action to maintain cable tension of

a cable net system within a small

range in the event of base dis-

placement , temperature change

and other adverse conditions.

Hence, the proper functioning of

components of the glass wall is

assured

Page 154: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

149

Cable tension overload protection device and cable tension assurance device are

designed for glass walls supported by cable net systems.

when the tension in the cables of a cable net system exceeds the design load, the

safety rod of the cable tension overload protection device will break,and the sping will

take over to ensure that cable tension will not exceed the designed value. Hance,

thecable net system and the glass wall will be maintained intact and secured.

Page 155: Point-Fixed Glass Wall Fitting Typical Product Catalog160P

150

DisclaimerAlthough the information and recommendations (hereinafter referred to as�information�) set forth

herein are presented in good faith and believed to be correct according to Chinese statutory regulation, theyare intended as a reference only and Hong Kong Kin Long Construction Hardware (Group) CO., Ltd(herinafter referred to as�Company�) will not be liable for any use that does not conform thereto. Thepersons recciving the information contained herein are responsible for determining as to its suitability for theirpurposes and that the product can be used for the purposes for which it is intended. Said persons are solelyresponsible for the methods and techniques they use. The company will not be responsible for any wrongfuluse of the product or any use which departs from the regulations in effect or is made under conditions whichare not suited to the purpose. The persons receiving the information contained herein are responsible forensuring that said information, as well as the product, do not violate patent laws. In no event will the companybe respnsible for any patent infringement by the product user or the information contained herein. Nothingcontained herein is to be constructed as a warranty, express or implied, The information is supplied forreference purposes only and is to be read as such by the user.

Note: The company reserves the right to change models, improve or modify the specifications andillustrated details showed herein, and to effect any change if it may deem necessary, without prior notification.