pneumatic
TRANSCRIPT
PNEUMATIC & HYDRAULIC
CHAPTER 1 : Introduction of Pneumatic System
Types of Air Compressor
Dynamic compressor
Piston compressor Rotary compressor Screw compressor
1. Single cylinder compressor 2. Double acting cylinder 3. Two stage compressor 4. Combined two stage compressor 5. Diaphragm compressor
Types of Rotary Compressor
Lobe compressor
Liquid ring compressor Vane compressor
Air Cooler
1. Cooling process done by using atmospheric air as a medium.
2. Using water as a medium of cooling.
Air Dryer
1. Adsorrption dryer
2. Refrigeration dryer
3. Air filter & water trap
CHAPTER 2 : Elements in Pneumatic Working System
Types of Linear Cylinder
Pneumatic cylinders : are mechanical devices use the power of compressed gas to produce a force in a reciprocating
linear motion.
Double acting cylinder
Single acting cylinder
Deliquescent dryer
Absorption dryer (heating)
Is a cylinder in which the working
fluid acts on one side of the piston only.
Is a cylinder in which the working fluid acts
alternately on both sides of the piston.
Cushioning in Pneumatic System
To decelerate a cylinder's piston before it strikes the end cap.
Reducing the piston velocity and reduces vibration transmitted to the machine structure.
Mounting Cylinder
Standard cylinders are not designed to absorb the load from the piston side.
The cylinder must be fitted with care and precision to ensure that the load movement parallel and balanced with the
center line of the cylinder.
Type of mounting cylinder.
Mounting directly (Direct)
• Cylinder mounted directly to the front surface of the rod
Mounting Threads (Threaded Neck)
• Cylinder fitted with lock nuts that are on the front of the cylinder.
Mounting Legged (Foot Mount)
• Cylinder mounted horizontally by installing two feet in front and behind the cylinder.
Suspension Mounting Rear (Rear Flange)
• Cylinder mounted on the back of the keyboard.
Front Suspension Mounting (Front Flange)
• Cylinder mounted on the front of the keyboard.
Oscillation Mounting Rear (Rear Clevis)
• Cylinder mounted on the front of the joints that can swing.
Trunnion Mounting
• Mounting hinge mounted on the center of the cylinder to allow it swing
Valve
Methods of how the valve is moved Figure Symbol
Human
Moved by the operator by means of pressing the
button provided.
Mechanical
Valve is actuated by a mechanical mechanism
such as wheeled switch and the cylinder rod.
Pneumatic
Valve is actuated by the compressed air that
act to move the position of wind channel.
Electrical
Valve is actuated by a solenoid powered by
electricity.
CHAPTER 3 : Pneumatic Circuit Design
CYLINDER NUMEROUS CONTROL
For operating multi-cylinder sequence control circuit below, there are two action pneumatic cylinder rod is moved or controlled
will take turns using the aid of pneumatic components.
TIME MOTION DIAGRAM
Figure movement time (RGM) or "Time Motion Chart", can describe a sequence of two or more cylinders are moved
automatically.
BUIDING CIRCUIT WITH CASCADE METHOD
To build a counter circuit step, you need a step counter module consists of valve 3/2 and valve AND. It has 6 points of
connection as pictured below. WARNING! You must draw a counter module form in step 3.9 diagram below so as not to
confuse the counter circuit construction step.
CHAPTER 4 : Hydraulic Component
CHAPTER 5 : Basic Hydraulic Circuit
To perform a useful task a hydraulic simple circuit consists of a group of parts such as pumps, actuators (motors and cylinders),
control valves and conductors (pipe and hoses).Hydraulic simple circuit is categorized into 2 types: open center and closed
center. The type of circuit is usually designated by directional control valves.
The basic design of an open circuit
Simple design with a fixed displacement pump, fixed displacement motor and cylinder block.
Direction of stroke and output are on one side.
A direction control valve (10) and bi-directional motor (3) was included in the system. By direction control valve the movement
of the actuators could be changed.
The basic design of a close circuit
This type of hydraulic system comprises a variable displacement pump and motor with interconnecting hydraulic lines. The flow
rate and direction of flow is controlled by the pump swivel angle. The motor may swivel on one side of centre and is also
adjustable.
Two relief valves were added in hydraulic system. Their function ensures maximum pressure and also protecting the system
against overload.
CHAPTER 6 : Hydraulic Circuit Design
Bleed-off speed control
Bleed-off circuits do not work with a running-away load.
When using a bleed-off circuit with a running-away load, use the counterbalance circuit.
Notice that a bypass check valve forces fluid through an adjustable orifice just before it enters the actuator. With a meter-in circuit, fluid enters the actuator at a controlled rate.
The action of meter-out flow controls is smooth and steady in hydraulic circuits.
meter-out flow controls are controlling the load on a down-acting vertical cylinder.
Diaphragm type Accumulators
Diaphragm type Accumulators Operations
Bladder type Accumulators
Operations Bladder Type Accumulators