PME5230 Midterm Presentation PME5230 Midterm Presentation 1
Temperature measurement and comTemperature measurement and compensation based on two vibrating mpensation based on two vibrating modes of a bulk acoustic mode microrodes of a bulk acoustic mode micror
esonator esonator
Teacher Teacher : : Cheng-Hsien Liu RReportereporter :: Chien Thanh NguyenChien Thanh Nguyen
DateDate :: 2008.4.162008.4.16
M.Koskenvuori1, V.Kaajakri2, T.Mattila and I. Tittonen1
1. Micro and Nanosciences laboratory and Center for New Materials, Helsinki University of Technology,Finland
2. VTT – Technical Research Center of Finland, Finland
MEMS 2008, Tucson, AZ, USA, January 13-17, 2008
PME5230 Midterm Presentation PME5230 Midterm Presentation 2
OutlineOutline Introduction Device Method Measurement results Discussion Conclusion
PME5230 Midterm Presentation PME5230 Midterm Presentation 3
IntroductionIntroduction
Temperature induced drift
MEMS resonator
Compensated electronicallyMaterial compensation SiO2
, Al2O3
PME5230 Midterm Presentation PME5230 Midterm Presentation 4
DeviceDevice
Single crystal silicon, square-extensional bulk-acoustic-mode resonator (SE-BAW)
Fundamental mode of vibration
Lame’ Mode
Square-extension mode
PME5230 Midterm Presentation PME5230 Midterm Presentation 5
MethodMethodDetermine temperature coefficients of the frequency of two mode
α1= ((df/f)/dT)lame= -22.3 ppm/K
α2 = ((df/f)/dT)SE = -27.3 ppm/K
PME5230 Midterm Presentation PME5230 Midterm Presentation 6
MethodMethod
(1)
(2)
PME5230 Midterm Presentation PME5230 Midterm Presentation 7
Measurement ResultsExperiment setup
1) Pt-100 sensor next to resonator chip
2) Resonator as a thermometer itself
PME5230 Midterm Presentation PME5230 Midterm Presentation 8
PT-100: frequency error: 15ppm
PT-100: compensation error df/f > 2 ppm
Resonator thermometer: compensated df/f < 1 ppm
PME5230 Midterm Presentation PME5230 Midterm Presentation 9
PME5230 Midterm Presentation PME5230 Midterm Presentation 10
DiscussionDiscussionDisadvantage:
1) A very accurate frequency measurement is needed
2) The beat frequency of the two modes is fairly high reducing the sensitivity
3) Any mixing products of the two excited modes will degenerate the reference oscillator noise performance
PME5230 Midterm Presentation PME5230 Midterm Presentation 11
ConclusionConclusionA resonator can be used as a thermometer by measuring the frequency change of the Lame- and SE- mode Temperature induced frequency shift can be compensated to better Provide a cost effective way to obtain crystal oscillator (TCXO) performance with inexpensive silicon resonator.
PME5230 Midterm Presentation PME5230 Midterm Presentation 12
Thank you for your attention!Thank you for your attention!
PME5230 Midterm Presentation PME5230 Midterm Presentation 13
ReferenceReferenceCMOS-compatible dual-resonator MEMS temperature se
nsor with mili-degree accuracyC.M. Jha, G. BAhl, R. Melamud, S.A. Chandorkar, M.A. Hopcroft, B. Kim, M. A
garwwal, J. Salvia, H. Mehta and T.W. Keny(transducer 2007)