PM-icx the Intelligent answer Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 1 01-12 PM-icx Power Monitors GAS SUPPLY CONTROL STATION with Fan Power Ventilation Inter-lock For Models: PM-1icx / PM-2icx INSTALLATION and COMMISSIONING INSTRUCTIONS

Upload: voduong

Post on 12-Aug-2018

224 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: PM-icx Power Monitors - - Trent Products 0_03 PM... · PM-icx the Intelligent answer Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 1 01-12 PM-icx Power Monitors GAS SUPPLY CONTROL

PM-icx the Intelligent answer

Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 1 01-12

PM-icx Power Monitors

GAS SUPPLY CONTROL STATION with

Fan Power Ventilation Inter-lock

For Models: PM-1icx / PM-2icx

INSTALLATION and COMMISSIONING INSTRUCTIONS

Page 2: PM-icx Power Monitors - - Trent Products 0_03 PM... · PM-icx the Intelligent answer Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 1 01-12 PM-icx Power Monitors GAS SUPPLY CONTROL

PM-icx the Intelligent answer

Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 2 01-12

Product Overview The PM-icx Fan power monitor unit is part of a range of products and ancillary equipment designed to meet the ever changing requirements of the catering industry and associated regulations. The system comes in a number of models for you to select which are based on our patented system.

The controller has been designed to make for easy system commissioning.

Contents

1.0 General Info

1.01 Opening the unit 1.02 Fixing details 1.03 Cable entry 1.04 Electrical connections 1.05 Component locations

2.0 Set-up and commissioning

2.01 Initial Set-up 2.02 Functional Set-up

3.0 Fault finding 4.0 Wiring and connection details 5.0 Technical specification

1.01 Opening the unit The PM-icx unit is made up of three (3) main component parts, one (1) PCB (printed circuit board), base enclosure and facia. The enclosure and facia are held together via four screws, the base enclosure houses the main PCB (printed circuit board) and the facia is attached to it via a multi-core ribbon cable. To open the enclosure, first remove the four screws; lift off the facia and unclip the ribbon cable from the main PCB. Place the screws and facia in a safe place until the base enclosure has been fixed, wired and is ready for reassembly and set-up. 1.02 Fixing details The PM-icx unit has four (4) mounting holes which can be used (as shown) Note: Ensure that the enclosure is mounted on a clean and level surface away from the direct cooking area or surfaces.

223

248

92.5

235

111.5

Page 3: PM-icx Power Monitors - - Trent Products 0_03 PM... · PM-icx the Intelligent answer Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 1 01-12 PM-icx Power Monitors GAS SUPPLY CONTROL

PM-icx the Intelligent answer

Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 3 01-12

1.03 Cable entry The PM-icx unit has space above, below and from behind the unit to allow for cable entry holes to be drilled. Care should be taken to prevent the PCB from damage. 1.04 Electrical connections The PM-icx unit has a 5Amp MCB on/off rocker switch for protection of the unit. There are two sets of terminals mounted along the edges of the main PCB circuit board. Terminals 1 to 18 are the smaller terminals (1.5 mm! cable) and are used for the inter-locking devices such as

“fire alarm” and “remote knock-off units”.(Screened cable must be used) Terminals 19 to 41 are the larger terminals (4 mm! cable) and are for the power connections for the fans, gas

valve and power supply to the unit. The terminals are of the rising clamp type with protection. All cabling should be kept to the top or bottom of the unit within the designated area. No cables should be placed or laid across the PCBs as they may cause damage.

19 20 21 22 23 24 25 26 27

USER DEFINABLE SELECTABLE INPUTS

ANTI-FLUTTER INSTANTANEOUS

181716 6 5 4 3 2 1

T6 T5 T4 T3 T2 T1

28 29 30 31 32 33 34 35 36 37 38 39 40 41

(NOT FITTED)

POWER SUPPLY GAS VALVE OUTPUT

ANCILLARY

OUTPUT

CHANNEL 2 CHANNEL 1

IN OUT IN OUT

N L E

IN OUT

N L E N L E N L EN L E N L EN L EN E

1.05 Component Locations The PM-icx unit has a number of components which need to be adjusted to set the system correctly. These are located at the top of the main PCB, under the left hand terminals and bottom right as detailed.

USER DEFINABLE INPUTS SYSTEMSET-POINTS

CHANNEL LINKS

POWERLINKS

MAIN PCB

CH 2 CH 1

MAX

MIN

T6 T5 T4 T3 T2 T1

J10

J16 J13 J11 J28J12

J26

J23

LINK 1

LINK 3

LINK 2

R64

R8

R65

R56

(NOT FITTED)

Page 4: PM-icx Power Monitors - - Trent Products 0_03 PM... · PM-icx the Intelligent answer Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 1 01-12 PM-icx Power Monitors GAS SUPPLY CONTROL

PM-icx the Intelligent answer

Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 4 01-12

Follow these instructions to correctly set-up your unit. 2.0 Set-up and Commissioning The set-up and commissioning of your PM-icx unit is in two parts, Initial and Functional. 2.01 Initial Set-up Once all of the wiring has been completed and tested and the system is ready to be set-up and commissioned, the following sequence MUST be followed to ensure the PM-icx unit and system operate correctly.

a) Input Jumpers, Ensure that the correct input jumpers have been removed as detailed in sections: 4.0 & 5.0. (located as detailed in 1.05)

b) Power Links, Ensure that these links have been selected correctly for your installation as detailed in sections: 4.0 & 5.0.

(located as detailed in 1.05) c) Channel Link, If you are using the PM-2ic as a single channel unit, remove Link J23 and place it in position J10 located

as detailed in 1.05. Note: When the system has been set to a single channel unit – channel 2 is ignored for fan proving purposes

d) Ensure that fire alarm and knock-off switches (if fitted) are all in the operational position.

e) Refit the PM-icx unit facia plate by plugging in the ribbon cable and fixing the four screws of the facia, with the top cover

plate removed so the system can be commissioned.

f) Ensure that you have set-up your fans, balanced the air system and you have set the min speed on the speed controllers (if fitted) to the minimum design air flow rate for the area.

2.02 Functional Set-up Once the above has been carried out, the system is now ready to be powered up. The upper and lower current limits need to be established to ensure correct operation of the gas valve interlock. 2.02.1 Working on one channel at a time, (CH 1 and then CH 2): Before you start, turn the MAX pot (R65 / R64) approximately 30 times CLOCKWISE. To set the MINIMUM current:

1. Set the respective fan to its MIN speed and then set the MIN pot (R56 / R8) to its set point by adjusting the pot ANTI-CLOCKWISE until the green LED above the pot is on. (If green LED is on to start with, adjust CLOCKWISE until it goes off and back ANTI-CLOCKWISE to bring it on again).

2. Adjust the same fan slowly from its MIN speed to its MAX speed; if the green LED goes off at any point, adjust the

MIN pot ANTI-CLOCKWISE until it comes back on. 3. When the fan is at its MAX speed, turn the MIN pot one further full turn ANTI-CLOCKWISE to allow for any

fluctuations. This pot is now set, and does not need to be adjusted again. To set the MAXIMUM current: 1. Set the MAX pot (R56 / R8) to its set point by adjusting the pot ANTI-CLOCKWISE until the green LED above the

pot is off, and then turning the pot CLOCKWISE until the LED comes back on. 2. Adjust the same fan slowly from its MAX speed to its MIN speed; if the green LED goes off at any point, adjust the

MAX pot CLOCKWISE until it comes back on. 3. When the fan is at its MIN speed, turn the MAX pot one further full turn CLOCKWISE to allow for any fluctuations.

This channel is now set correctly, and you can proceed to the second channel (if required). 2.02.2 When both channels have been set, press the green SYSTEM SET pad once, the gas valve LED will go to GREEN and the gas valve output and ancillary output will be activated.

Page 5: PM-icx Power Monitors - - Trent Products 0_03 PM... · PM-icx the Intelligent answer Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 1 01-12 PM-icx Power Monitors GAS SUPPLY CONTROL

PM-icx the Intelligent answer

Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 5 01-12

2.02.3 With the system running and the gas valve output on, the following tests should be carried out.

1) Press the Emergency Gas Shut Off on the front of the panel; the gas valve output will go off and the gas valve output LED will go out and the alarm will sound.

2) Press the blue ALARM MUTE pad and twist Emergency Gas Shut Off to release it and press the green SYSTEM

SET pad to restart. 3) Repeat this for any remote knock-off button fitted and the fire alarm. 4) Switch off each fan in turn and watch the gas valve output go off. 5) Switch the fans back on, and press the green SYSTEM SET pad to restart. Set each fan to a few different

speeds and leave for a short time to ensure the gas valve output stays on. 6) The set-up is now complete and the system is ready for normal operation.

2.02.5 Adjustment POTs

The two adjustment POTs per channel are multi-turn units (approx: 30 turns). These enable fine setting of the two switching points (min & max).

3.0 Fault finding In the event that your PM-icx unit has not operated, the following has been designed to help you identify your problem and offer a course of action for you to take. Fault finding Only to be carried out by a qualified engineer

Fault Possible cause Action No Power On LED a. No power to the unit Check power supply to unit, mains cables and

terminals b. Primary transformer fuse “blown” Remove cover and check if “blown”. If yes, check

for any signs of a wiring fault and rectify before replacing with a new fuse.

c. None of the above Call for further assistance Gas valve output lamp is not lit and gas valve is closed

a. Fans are not running Check that the fans are running correctly

b. Fans are running but unit not set correctly Check that the respective channel lamps are on. Action as detailed in set-up instructions

c. User definable input operated Check if remote knock-off and fire alarm inputs and any other remote circuits have been activated

d. Emergency Gas Shut off push button on the front of the unit has been pressed

Twist and reset

Gas valve output lamp is on and gas valve is closed

a. No power to gas valve Check in / out terminals to see if 240Vac is present and check cables to gas valve.

b. Gas valve not operational Check if 240Vac is present at gas valve terminals. If yes replace gas valve.

Gas valve open but no gas at appliance

a. Gas supply has been isolated or is blocked

Check gas supply

b. No gas pressure Check gas supply Channel lamp not on a. Fans are not running Check that the fans are running correctly b. Fans are running but unit not set correctly Check that the respective channel lamps are on.

Action as detailed in set-up instructions

ONOFF

MULTI-TURN

ON OFF

MULTI-TURN

MAX POTMIN POT

= GREEN CHANNEL LEDON

Page 6: PM-icx Power Monitors - - Trent Products 0_03 PM... · PM-icx the Intelligent answer Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 1 01-12 PM-icx Power Monitors GAS SUPPLY CONTROL

PM-icx the Intelligent answer

Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 6 01-12

4.0 Wiring and connection details

The following information should be read in conjunction with the respective PM wiring diagram for your model. User definable inputs (Screened cable recommended)

Gas Valve Output

Ancillary Output (Electric Fryer etc)

REMOVE JUMPERTO ACTIVATEINPUT TERMINALS

MAX 1.5mm CABLE

E

INSTANTANEOUS INPUT

E

CN/O

MAX 1.5mm CABLE

REMOVE JUMPERTO ACTIVATEINPUT TERMINALS

INSTANTANEOUS INPUT

REMOTE KNOCK-OFF FIRE ALARM CONTACTPUSH BUTTON

E

CN/O

AIR FLOW PROVING DEVICE

MAX 1.5mm CABLE

REMOVE JUMPERTO ACTIVATEINPUT TERMINALS

ANTI-FLUTTER INPUT

MAX 4mm CABLE

REMOVE LINKS

N L E N L E

N L E

GAS VALVE

OUTIN

LINK 1

LINK 2

GAS VALVE OUTPUTWITH POWER SUPPLY FROM PM UNIT

MAX 4mm CABLE

N L E N L E

N L E

GAS VALVE

OUTIN

LINK 1

LINK 2

GAS VALVE OUTPUTWITH POWER SUPPLY FROM LOCAL CIRCUIT

N L E

LOCAL SUPPLY

MAX 1.5mm CABLE

LINK 3

N L

LINK 3

Page 7: PM-icx Power Monitors - - Trent Products 0_03 PM... · PM-icx the Intelligent answer Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 1 01-12 PM-icx Power Monitors GAS SUPPLY CONTROL

PM-icx the Intelligent answer

Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 7 01-12

5.0 Technical Specification The following information should be read in conjunction with the wiring diagram for the model being fitted and commissioned. It is correct at the time of going to print, but we reserve the right to change at any time the materials and information hereto detailed.

Inputs:

• fan Power 240Vac 50Hz (0 – 10 Amps max each channel) Optional 20Amp • optional Fire alarm and / or Carbon Monoxide sensor • optional Air Flow differential pressure switch or proving product • optional Remote emergency stop

Outputs:

• fan Power 240Vac 50Hz (0 – 10 Amps max each channel) Optional 20Amp • gas Valve output selectable 240Vac or Volt-free contact (6 Amp 240Vac 50Hz) • ancillary output selectable 240Vac or Volt-free contact (4 Amp 240Vac 50Hz)

PCB adjustments and jumper links (Main PCB – issue 9): MIN Current level switch point 0 to 10 Amps (each channel)

MAX Current level switch point 0 to 10 Amps (each channel) 30 sec delay * J28 Remote emergency stop Yes/No J11 Fire alarm Yes/No J26 Air flow DPS (if required) Yes/No (Anti-flutter) J10/23 Channel select Yes/No

LED Green indicator Current switch point (each channel) LED Red indicator Gas valve output activated

Front of unit indication and pads (Facia PCB – issue 2): LEDs Power on Gas Valve Output Off = Closed Green = Open Fan 1 & 2 Off = Fault Green = Running PADS System Set Green = Start system when fans are running Alarm Mute Blue = Mute audible alarm Power supply: 240Vac 50Hz 5Amp MCB rocker switch (illuminated Red) Transformer: F3 1Amp Primary Transformer Fuse Consumption: Approx 5VA Housing: IP 54 Dimensions: 250 x 235 x 60mm (approx) Ambient range: -10 to +40 Deg.C Country of Origin: UK Note: The MAX current level settings have a 30 sec over current delay before switching off the gas valve and ancillary outputs.

Page 8: PM-icx Power Monitors - - Trent Products 0_03 PM... · PM-icx the Intelligent answer Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 1 01-12 PM-icx Power Monitors GAS SUPPLY CONTROL

PM-icx the Intelligent answer

Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 8 01-12

T1T2

2 CORE SCREENCABLE

REMOVE BLUE JUMPER J11

J11 J28

SELECTABLE INPUTS

SCREEN CONNECTEDAT CONTROLLER END ONLYFRONT VIEW VIEW INSIDE LID

PM-ICX CIRCUIT BOARD

NOTE: KNOCK-OFF PUSH BUTTON REQUIRESA NORMALLY CLOSED CONTACT. OPEN WHENBUTTON IS PRESSED

T1T2

2 CORE SCREENCABLE

REMOVE BLUE JUMPER J28

J11 J28

SELECTABLE INPUTS

SCREEN CONNECTEDAT CONTROLLER END ONLY

PM-ICX CIRCUIT BOARD

NOTE: FIRE ALARM OUTPUT REQUIRESA NORMALLY CLOSED CONTACT. OPEN WHENIN FIRE ALARM MODE

NC

NO

COM

FIRE ALARM OUTPUTRELAY MODULE

VOLT-FREE CONTACT

Page 9: PM-icx Power Monitors - - Trent Products 0_03 PM... · PM-icx the Intelligent answer Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 1 01-12 PM-icx Power Monitors GAS SUPPLY CONTROL

DR

AW

N B

YD

RA

WIN

G N

o:D

AT

E:

01

23

45

67

89

NN

LE

E

NL

EN

LE

LIN

K 1

LIN

K 3

LIN

K 2

INO

UT

GA

S V

ALV

E

NL

EN

LE

NL

EN

LE

ININ

OU

TO

UT

FAN

UN

IT C

H: 2

FAN

UN

IT C

H:1

SC

AN

CIL

NL

EN

LE

INO

UT

FAN

UN

IT C

H:1

ELN

ELNE L N

LOC

AL

ISO

LATO

R(S

ee N

ote:

1)

FAN

MO

TOR

STA

RT

/ STO

PC

ON

TRO

L(S

ee N

ote:

2)

ELN

LOC

AL

240V

acFU

SE

D S

UP

PLY

(See

Not

e: 3

)

TYPI

CAL

WIR

ING

AR

RAN

GEM

ENT

FOR

A F

AN M

OTO

RW

ITH

A M

ANU

AL S

TAR

T ST

OP

CO

NTR

OL

NL

EN

LE

INO

UT

FAN

UN

IT C

H:1

E L N

E L N

E L N

LOC

AL

ISO

LATO

R(S

ee N

ote:

1)

FAN

MO

TOR

SP

EE

DC

ON

TRO

LLE

R(S

ee N

ote:

2)

ELN

LOC

AL

240V

acFU

SE

D S

UP

PLY

(See

Not

e: 3

)

TYPI

CAL

WIR

ING

AR

RAN

GEM

ENT

FOR

A F

AN M

OTO

RW

ITH

A M

ANU

AL S

PEED

CO

NTR

OLL

ER

NO

TES

:1)

LO

CA

L IS

OLA

TIO

N M

US

T B

E P

RO

VID

ED

IN A

CC

OR

DA

NC

EW

ITH

TH

E C

UR

RE

NT

ED

ITIO

N O

F TH

E IE

E R

EG

ULA

TIO

NS

.

2)

CH

EC

K M

AN

UFA

CTU

RE

R'S

WIR

ING

DE

TAIL

S F

OR

CO

RR

EC

TC

ON

NE

CTI

ON

S A

ND

SE

T-U

P R

EQ

UIR

EM

EN

TS.

3)

EN

SU

RE

TH

AT

THE

PO

WE

R S

UP

PLY

IS C

OR

RE

CTL

Y FU

SE

DTO

TH

E S

IZE

OF

THE

FA

N M

OTO

R A

ND

TH

AT

OV

ER

LOA

DP

RO

TEC

TIO

N IS

FIT

TED

TO

TH

E C

UR

RE

NT

RE

GU

LATI

ON

S.

4)

EN

SU

RE

TH

AT

THE

PO

WE

R S

UP

PLY

IS C

OR

RE

CT

FOR

THE

LO

AD

ING

OF

THE

PO

WE

R M

ON

ITO

R A

ND

/ O

R G

AS

VA

LVE

.

NN

LE

E

E LN

LOC

AL

240V

acP

OW

ER

SU

PP

LY(S

ee N

ote:

4)

PO

WE

R S

UP

PLY

PO

WE

R S

UP

PLY

LIN

K 1

LIN

K 3

LIN

K 2

NL

EN

LE

INO

UT

GA

S V

ALV

E

NL

E

LOC

AL

ISO

LATO

R(S

ee N

ote:

1)

GA

S V

ALV

E

GAS

VAL

VE O

UTP

UT

WIT

H P

OW

ER S

UPP

LY F

RO

M P

M U

NIT

LIN

K 1

LIN

K 3

LIN

K 2

NL

EN

LE

INO

UT

GA

S V

ALV

E

NL

E

LOC

AL

ISO

LATO

R(S

ee N

ote:

1)

GA

S V

ALV

EELN

LOC

AL

240V

acFU

SE

D S

UP

PLY

(See

Not

e: 4

) GAS

VAL

VE O

UTP

UT

WIT

H P

OW

ER S

UPP

LY F

RO

M L

OC

AL S

UPP

LY(w

ith L

INK

S 1

& 2

rem

oved

)

PM U

NIT

PO

WER

SU

PPLY

RE

MO

VE

JU

MP

ER

TO A

CTI

VA

TEIN

PU

T TE

RM

INA

LS

RE

MO

TE K

NO

CK

-OFF

PU

SH

BU

TTO

N

MA

X 1.

5mm

CA

BLE

E

INST

ANTA

NEO

US

INPU

T

E

CN

/OFIR

E A

LAR

MC

ON

TAC

T

RE

MO

VE

JU

MP

ER

TO A

CTI

VA

TEIN

PU

T TE

RM

INA

LS

INST

ANTA

NEO

US

INPU

T

E

CN

/OAIR

FLO

WP

RO

VIN

G D

EV

ICE

MA

X 1.

5mm

CA

BLE

RE

MO

VE

JU

MP

ER

TO A

CTI

VA

TEIN

PU

T TE

RM

INA

LS

AN

TI-F

LUTT

ER

INP

UT

T6T5

T4T3

T2T1

SE

LEC

TAB

LE IN

PU

TS

INS

TAN

TAN

EO

US

AN

TI-F

LUTT

ER

CIR

CU

IT B

OAR

D L

AYO

UT

SELE

CTA

BLE

INPU

TS

01/1

1/06

PM

-icx-

WD

01M

AE

PM

-1ic

x &

PM

-2ic

x FA

N P

OW

ER

MO

NIT

OR

WIR

ING

& C

ON

NE

CTI

ON

DIA

GR

AM

Tel:

0178

2 - 8

4468

8 F

ax: 0

1782

- 84

4772

IF IN

DO

UB

T, A

SK

RE

PE

AT

PO

WER

WIR

ING

FO

R C

HA

NN

EL

2 A

S P

ER

CH

AN

NE

L 1

5 A

MP

MC

BR

OC

KE

R S

WIT

CH

Page 10: PM-icx Power Monitors - - Trent Products 0_03 PM... · PM-icx the Intelligent answer Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 1 01-12 PM-icx Power Monitors GAS SUPPLY CONTROL

DR

AW

B

YD

RA

WI

G

o:D

ATE

:

01

23

45

67

89

NN

LE

E

LIN

K 1

LIN

K 3

LIN

K 2

ININ

OU

TO

UT

TYPI

CAL

WIR

ING

AR

RAN

GEM

ENT

FOR

A FA

N M

OTO

R W

ITH

A M

ANU

AL S

TAR

T ST

OP

CO

NTR

OL

L1 L2 L3

L1 L2 L3

LOC

AL

ISO

LATO

R(S

ee N

ote:

1)

FAN

MO

TOR

SP

EE

DC

ON

TRO

LLE

R(S

ee N

ote:

2)

L3L2L1

LOC

AL

415V

acFU

SE

D S

UP

PLY

(See

Not

e: 3

)

TYPI

CAL

WIR

ING

AR

RAN

GEM

ENT

FOR

A FA

N M

OTO

R W

ITH

A M

ANU

AL S

PEED

CO

NTR

OLL

ER

NO

TES

:1)

LO

CA

L IS

OLA

TIO

N M

US

T B

E P

RO

VID

ED

IN A

CC

OR

DA

NC

EW

ITH

TH

E C

UR

RE

NT

ED

ITIO

N O

F TH

E IE

E R

EG

ULA

TIO

NS

.

2)

CH

EC

K M

AN

UFA

CTU

RE

R'S

WIR

ING

DE

TAIL

S F

OR

CO

RR

EC

TC

ON

NE

CTI

ON

S A

ND

SE

T-U

P R

EQ

UIR

EM

EN

TS.

3)

EN

SU

RE

TH

AT

THE

PO

WE

R S

UP

PLY

IS C

OR

RE

CTL

Y FU

SE

DTO

TH

E S

IZE

OF

THE

FA

N M

OTO

R A

ND

TH

AT

OV

ER

LOA

DP

RO

TEC

TIO

N IS

FIT

TED

TO

TH

E C

UR

RE

NT

RE

GU

LATI

ON

S.

4)

EN

SU

RE

TH

AT

THE

SW

ITC

HE

D P

OW

ER

IS C

OR

RE

CTL

Y FU

SE

DTO

TH

E L

OA

DIN

G O

F TH

E P

OW

ER

MO

NIT

OR

AN

D /

OR

GA

S V

ALV

E.

NN

LE

E

ELN

LOC

AL

240V

acS

WIT

CH

ED

FU

SE

DP

OW

ER

SU

PP

LY(S

ee N

ote:

4)

PO

WE

R S

UP

PLY

PO

WE

R S

UP

PLY

LIN

K 1

LIN

K 3

LIN

K 2

NL

EN

LE

INO

UT

GA

S V

ALV

E

NL

E

LOC

AL

ISO

LATO

R(S

ee N

ote:

1)

GA

S V

ALV

E

GAS

VAL

VE O

UTP

UT

WIT

H P

OW

ER S

UPP

LY F

RO

M P

M U

NIT

LIN

K 1

LIN

K 3

LIN

K 2

NL

EN

LE

INO

UT

GA

S V

ALV

E

NL

E

LOC

AL

ISO

LATO

R(S

ee N

ote:

1)

GA

S V

ALV

EELN

LOC

AL

240V

acFU

SE

D S

UP

PLY

(See

Not

e: 4

) GAS

VAL

VE O

UTP

UT

WIT

H P

OW

ER S

UPP

LY F

RO

M L

OC

AL S

UPP

LY(w

ith L

INK

S 1

& 2

rem

oved

)

PM U

NIT

PO

WER

SU

PPLY

RE

MO

VE

JU

MP

ER

TO A

CTI

VA

TEIN

PU

T TE

RM

INA

LS

REM

OTE

KN

OC

K-O

FFPU

SH B

UTT

ON

MA

X 1

.5m

m C

AB

LE

E

INST

ANTA

NEO

US

INPU

T

E

CN

/OFIR

E AL

ARM

CO

NTA

CT

RE

MO

VE

JU

MP

ER

TO A

CTI

VA

TEIN

PU

T TE

RM

INA

LS

INST

ANTA

NEO

US

INPU

T

E

CN

/OAIR

FLO

WPR

OVI

NG

DEV

ICE

MA

X 1

.5m

m C

AB

LE

RE

MO

VE

JU

MP

ER

TO A

CTI

VA

TEIN

PU

T TE

RM

INA

LS

ANTI

-FLU

TTER

INPU

T

T6T5

T4T3

T2T1

SE

LEC

TAB

LE IN

PU

TS INS

TAN

TAN

EO

US

AN

TI-F

LUTT

ER

CIR

CU

IT B

OAR

D L

AYO

UT

SELE

CTA

BLE

INPU

TS

17/0

1/12

PM

-icx-

3P-W

D02

JH-P

PM

-1ic

x &

PM

-2ic

x FA

N P

OW

ER

MO

NIT

OR

THR

EE

PH

AS

E W

IRIN

G &

CO

NN

EC

TIO

N D

IAG

RA

MTe

l: 01

782

- 844

688

Fax

: 017

82 -

8447

72

IF IN

DO

UB

T, A

SK

RE

PE

AT

PO

WE

R W

IRIN

G F

OR

CH

AN

NE

L 2

AS

PE

R C

HA

NN

EL

1

L2L3

EL1 L2 L3

FAN

UN

IT C

H: 2

FAN

UN

IT C

H:1

L1 L2 L3

LOC

AL

ISO

LATO

R(S

ee N

ote:

1)

FAN

MO

TOR

L3L2L1LOC

AL

415V

acFU

SE

D S

UP

PLY

(See

Not

e: 3

)

E

L3L2L1

L3L2L1

STA

RT

/ STO

PC

ON

TRO

L(S

ee N

ote:

2)

NL

EN

LE

INO

UT

GA

S V

ALV

E

NL

EN

LE

NL

EN

LE

ININ

OU

TO

UT

FAN

UN

IT C

H: 2

FAN

UN

IT C

H:1

SC

AN

CIL

L2L3

L2L3

L2L3

LE

LE

INO

UT

FAN

UN

IT C

H:1

FAN

UN

IT C

H: 2

FAN

UN

IT C

H:1

LE

LE

INO

UT

FAN

UN

IT C

H:1

Page 11: PM-icx Power Monitors - - Trent Products 0_03 PM... · PM-icx the Intelligent answer Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 1 01-12 PM-icx Power Monitors GAS SUPPLY CONTROL

DR

AW

B

YD

RA

WI

G

o:D

ATE

:

01

23

45

67

89

NN

LE

E

NL

EN

LE

LIN

K 1

LIN

K 3

LIN

K 2

INO

UT

GA

S V

ALV

E

ININ

OU

TO

UT

FAN

UN

IT C

H: 2

FAN

UN

IT C

H:1

SC

AN

CIL

TYPI

CAL

WIR

ING

AR

RAN

GEM

ENT

FOR

A F

AN M

OTO

RW

ITH

A M

ANU

AL S

TAR

T ST

OP

CO

NTR

OL

E L N

E L N

LOC

AL

ISO

LATO

R(S

ee N

ote:

1)

FAN

MO

TOR

SP

EE

DC

ON

TRO

LLE

R(S

ee N

ote:

2)

NLE

LOC

AL

240V

acFU

SE

D S

UP

PLY

(See

Not

e: 3

)

TYPI

CAL

WIR

ING

AR

RAN

GEM

ENT

FOR

A F

AN M

OTO

RW

ITH

A M

ANU

AL S

PEED

CO

NTR

OLL

ER

NO

TES

:1)

LO

CA

L IS

OLA

TIO

N M

US

T B

E P

RO

VID

ED

IN A

CC

OR

DA

NC

EW

ITH

TH

E C

UR

RE

NT

ED

ITIO

N O

F TH

E IE

E R

EG

ULA

TIO

NS

.

2)

CH

EC

K M

AN

UFA

CTU

RE

R'S

WIR

ING

DE

TAIL

S F

OR

CO

RR

EC

TC

ON

NE

CTI

ON

S A

ND

SE

T-U

P R

EQ

UIR

EM

EN

TS.

3)

EN

SU

RE

TH

AT

THE

PO

WE

R S

UP

PLY

IS C

OR

RE

CTL

Y FU

SE

DTO

TH

E S

IZE

OF

THE

FA

N M

OTO

R A

ND

TH

AT

OV

ER

LOA

DP

RO

TEC

TIO

N IS

FIT

TED

TO

TH

E C

UR

RE

NT

RE

GU

LATI

ON

S.

4)

EN

SU

RE

TH

AT

THE

SW

ITC

HE

D P

OW

ER

IS C

OR

RE

CTL

Y FU

SE

DTO

TH

E L

OA

DIN

G O

F TH

E P

OW

ER

MO

NIT

OR

AN

D /

OR

GA

S V

ALV

E.

NN

LE

E

ELN

LOC

AL

240V

acS

WIT

CH

ED

FU

SE

DP

OW

ER

SU

PP

LY(S

ee N

ote:

4)

PO

WE

R S

UP

PLY

PO

WE

R S

UP

PLY

LIN

K 1

LIN

K 3

LIN

K 2

NL

EN

LE

INO

UT

GA

S V

ALV

E

NL

E

LOC

AL

ISO

LATO

R(S

ee N

ote:

1)

GA

S V

ALV

E

GAS

VAL

VE O

UTP

UT

WIT

H P

OW

ER S

UPP

LY F

RO

M P

M U

NIT

LIN

K 1

LIN

K 3

LIN

K 2

NL

EN

LE

INO

UT

GA

S V

ALV

E

NL

E

LOC

AL

ISO

LATO

R(S

ee N

ote:

1)

GA

S V

ALV

EELN

LOC

AL

240V

acFU

SE

D S

UP

PLY

(See

Not

e: 4

) GAS

VAL

VE O

UTP

UT

WIT

H P

OW

ER S

UPP

LY F

RO

M L

OC

AL S

UPP

LY(w

ith L

INK

S 1

& 2

rem

oved

)

PM U

NIT

PO

WER

SU

PPLY

RE

MO

VE

JU

MP

ER

TO A

CTI

VA

TEIN

PU

T TE

RM

INA

LS

REM

OTE

KN

OC

K-O

FFPU

SH B

UTT

ON

MA

X 1

.5m

m C

AB

LE

E

INST

ANTA

NEO

US

INPU

T

E

CN

/OFIR

E AL

ARM

CO

NTA

CT

RE

MO

VE

JU

MP

ER

TO A

CTI

VA

TEIN

PU

T TE

RM

INA

LS

INST

ANTA

NEO

US

INPU

T

E

CN

/OAIR

FLO

WPR

OVI

NG

DEV

ICE

MA

X 1

.5m

m C

AB

LE

RE

MO

VE

JU

MP

ER

TO A

CTI

VA

TEIN

PU

T TE

RM

INA

LS

ANTI

-FLU

TTER

INPU

T

T6T5

T4T3

T2T1

SE

LEC

TAB

LE IN

PU

TS INS

TAN

TAN

EO

US

AN

TI-F

LUTT

ER

CIR

CU

IT B

OA

RD

LA

YOU

T

SELE

CTA

BLE

INPU

TS

17/0

1/12

PM

-icx-

20-W

D01

JH-P

PM

-1ic

x &

PM

-2ic

x FA

N P

OW

ER

MO

NIT

OR

SIN

GLE

PH

AS

E W

IRIN

G &

CO

NN

EC

TIO

N D

IAG

RA

MTe

l: 01

782

- 844

688

Fax

: 017

82 -

8447

72

IF IN

DO

UB

T, A

SK

RE

PE

AT

PO

WE

R W

IRIN

G F

OR

CH

AN

NE

L 2

AS

PE

R C

HA

NN

EL

1

Max

20A

FLC

Max

20A

FLC

EN

L

E L N

FAN

UN

IT C

H: 2

FAN

UN

IT C

H:1

LOC

AL

ISO

LATO

R(S

ee N

ote:

1)

FAN

MO

TOR

LOC

AL

240V

acFU

SE

D S

UP

PLY

(See

Not

e: 3

)

FAN

UN

IT C

H: 2

FAN

UN

IT C

H:1

STA

RT

/ STO

PC

ON

TRO

L(S

ee N

ote:

2)

EN

LE

NL

EN

L

E L N

E L N

E L N

E L N

Page 12: PM-icx Power Monitors - - Trent Products 0_03 PM... · PM-icx the Intelligent answer Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 1 01-12 PM-icx Power Monitors GAS SUPPLY CONTROL

DR

AW

B

YD

RA

WI

G

o:D

ATE

:

01

23

45

67

89

NN

LE

E

NL

EN

LE

LIN

K 1

LIN

K 3

LIN

K 2

INO

UT

GA

S V

ALV

E

ININ

OU

TO

UT

FAN

UN

IT C

H: 2

FAN

UN

IT C

H:1

SC

AN

CIL

TYPI

CAL

WIR

ING

AR

RAN

GEM

ENT

FOR

A F

AN M

OTO

RW

ITH

A M

ANU

AL S

TAR

T ST

OP

CO

NTR

OL

L1 L2 L3

L1 L2 L3

LOC

AL

ISO

LATO

R(S

ee N

ote:

1)

FAN

MO

TOR

SP

EE

DC

ON

TRO

LLE

R(S

ee N

ote:

2)

L3L2L1

LOC

AL

240V

acFU

SE

D S

UP

PLY

(See

Not

e: 3

)

TYPI

CAL

WIR

ING

AR

RAN

GEM

ENT

FOR

A F

AN M

OTO

RW

ITH

A M

ANU

AL S

PEED

CO

NTR

OLL

ER

NO

TES:

1)

LOC

AL

ISO

LATI

ON

MU

ST

BE

PR

OV

IDE

D IN

AC

CO

RD

AN

CE

WIT

H T

HE

CU

RR

EN

T E

DIT

ION

OF

THE

IEE

RE

GU

LATI

ON

S.

2)

CH

EC

K M

AN

UFA

CTU

RE

R'S

WIR

ING

DE

TAIL

S F

OR

CO

RR

EC

TC

ON

NE

CTI

ON

S A

ND

SE

T-U

P R

EQ

UIR

EM

EN

TS.

3)

EN

SU

RE

TH

AT

THE

PO

WE

R S

UP

PLY

IS C

OR

RE

CTL

Y FU

SE

DTO

TH

E S

IZE

OF

THE

FA

N M

OTO

R A

ND

TH

AT

OV

ER

LOA

DP

RO

TEC

TIO

N IS

FIT

TED

TO

TH

E C

UR

RE

NT

RE

GU

LATI

ON

S.

4)

EN

SU

RE

TH

AT

THE

SW

ITC

HE

D P

OW

ER

IS C

OR

RE

CTL

Y FU

SE

DTO

TH

E L

OA

DIN

G O

F TH

E P

OW

ER

MO

NIT

OR

AN

D /

OR

GA

S V

ALV

E.

NN

LE

E

ELN

LOC

AL

240V

acS

WIT

CH

ED

FU

SE

DP

OW

ER

SU

PP

LY(S

ee N

ote:

4)

PO

WE

R S

UP

PLY

PO

WE

R S

UP

PLY

LIN

K 1

LIN

K 3

LIN

K 2

NL

EN

LE

INO

UT

GA

S V

ALV

E

NL

E

LOC

AL

ISO

LATO

R(S

ee N

ote:

1)

GA

S V

ALV

E

GAS

VAL

VE O

UTP

UT

WIT

H P

OW

ER S

UPP

LY F

RO

M P

M U

NIT

LIN

K 1

LIN

K 3

LIN

K 2

NL

EN

LE

INO

UT

GA

S V

ALV

E

NL

E

LOC

AL

ISO

LATO

R(S

ee N

ote:

1)

GA

S V

ALV

EELN

LOC

AL

240V

acFU

SE

D S

UP

PLY

(See

Not

e: 4

) GAS

VAL

VE O

UTP

UT

WIT

H P

OW

ER S

UPP

LY F

RO

M L

OC

AL S

UPP

LY(w

ith L

INK

S 1

& 2

rem

oved

)

PM U

NIT

PO

WER

SU

PPLY

RE

MO

VE

JU

MP

ER

TO A

CTI

VA

TEIN

PU

T TE

RM

INA

LS

REM

OTE

KN

OC

K-O

FFPU

SH B

UTT

ON

MA

X 1

.5m

m C

AB

LE

E

INST

ANTA

NEO

US

INPU

T

E

CN

/OFIR

E AL

ARM

CO

NTA

CT

RE

MO

VE

JU

MP

ER

TO A

CTI

VA

TEIN

PU

T TE

RM

INA

LS

INST

ANTA

NEO

US

INPU

T

E

CN

/OAIR

FLO

WP

RO

VIN

G D

EV

ICE

MA

X 1

.5m

m C

AB

LE

RE

MO

VE

JU

MP

ER

TO A

CTI

VA

TEIN

PU

T TE

RM

INA

LS

ANTI

-FLU

TTER

INPU

T

T6T5

T4T3

T2T1

SE

LEC

TAB

LE IN

PU

TS INS

TAN

TAN

EO

US

AN

TI-F

LUTT

ER

CIR

CU

IT B

OAR

D L

AYO

UT

SELE

CTA

BLE

INPU

TS

17/0

1/12

PM

-icx-

20-W

D02

JH-P

PM

-1ic

x &

PM

-2ic

x FA

N P

OW

ER

MO

NIT

OR

THR

EE

PH

AS

E W

IRIN

G &

CO

NN

EC

TIO

N D

IAG

RA

MTe

l: 01

782

- 844

688

Fax

: 017

82 -

8447

72

IF IN

DO

UB

T, A

SK

RE

PE

AT

PO

WE

R W

IRIN

G F

OR

CH

AN

NE

L 2

AS

PE

R C

HA

NN

EL

1

Max

20A

FLC

Max

20A

FLC

L1L2

L3L1

L2L3

EE

L1L2

L3L1

L2L3

EL1 L2 L3

FAN

UN

IT C

H: 2

FAN

UN

IT C

H:1

L1 L2 L3

LOC

AL

ISO

LATO

R(S

ee N

ote:

1)

FAN

MO

TOR

L3L2L1

LOC

AL

240V

acFU

SE

D S

UP

PLY

(See

Not

e: 3

)

E

FAN

UN

IT C

H: 2

FAN

UN

IT C

H:1

L3L2L1

L3L2L1

STA

RT

/ STO

PC

ON

TRO

L(S

ee N

ote:

2)

Page 13: PM-icx Power Monitors - - Trent Products 0_03 PM... · PM-icx the Intelligent answer Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 1 01-12 PM-icx Power Monitors GAS SUPPLY CONTROL

TO C

HA

NG

E A

TW

IN C

HA

NN

EL

UN

IT

TO A

SIN

GLE

CH

AN

NE

L U

NIT

JU

ST

MO

VE

BLU

E J

UM

PER

FR

OM

J23

A

ND

PLA

CE

ON

J10

CH

ANN

EL 1

& 2

LE

D

IND

ICA

TOR

S

AU

TO R

ES

ET

JUM

PER

J20

D13

GA

S V

ALV

E

OP

EN

LE

D

GAS

VAL

VE R

ELA

Y

PO

WE

R F

EED

LIN

KS

1, 2

, 3

MA

X P

OTS

R

64 &

R65

M

IN P

OTS

R

8 &

R56

PM-2

icx

Twin

Cha

nnel

PC

B

Page 14: PM-icx Power Monitors - - Trent Products 0_03 PM... · PM-icx the Intelligent answer Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 1 01-12 PM-icx Power Monitors GAS SUPPLY CONTROL

PM-icx the Intelligent answer

Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 14 01-12

Notes:

Page 15: PM-icx Power Monitors - - Trent Products 0_03 PM... · PM-icx the Intelligent answer Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 1 01-12 PM-icx Power Monitors GAS SUPPLY CONTROL

PM-icx the Intelligent answer

Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 15 01-12

Notes:

Page 16: PM-icx Power Monitors - - Trent Products 0_03 PM... · PM-icx the Intelligent answer Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 1 01-12 PM-icx Power Monitors GAS SUPPLY CONTROL

PM-icx the Intelligent answer

Model: PM-1icx / PM-2icx REF: PM-INST1 0.01 Page 16 01-12

FOR FURTHER TECHNICAL ASSISTANCE, PLEASE CONTACT US BY Phone: 01782 844688 Fax: 01782 844772 E-mail: [email protected] Web site: www.trentproducts.com Note: i) Ensure that the electrical installation has been installed in

accordance with the current edition of the IEE regulations.

ii) Ensure that the gas installation has been installed in accordance with the current gas regulations and CORGI guide-lines.

iii) Ensure that the ventilation and extract system has been set to the correct air flow

design levels in accordance with the current regulations. iv) If in doubt, ask! (contact us on or by any of the above).

v) Ensure that the client has been shown how to operate the system and that they have

been handed the users guide.

This symbol on this product or the package indicates that disposal of this product after its lifecycle could harm the environment. DO NOT dispose of this product (or batteries if used) as unsorted municipal waste. It should be disposed by a specialised company for recycling. This product should be returned to your distributor or to a local recycling service. Respect the local environment rules.

TRENT PRODUCTS Trent House

Dewsbury Road Fenton

Stoke-on-Trent Tel: 01782 844688 Fax: 01782 844772

Web: www.trentproducts.com e-mail: [email protected]