plate exchanger
DESCRIPTION
SHEETDATATRANSCRIPT
EXCHANGER SPECIFICATION SHEET01 Plant Item no. E-100
02 Service of Unit STEAM CONDENSATE Rev. No 0 Date - 29.01.15
03 Size Type PLATE Position horizontal
04 Surface of Unit Sq.M. Surface Per Shell
05 No. Of Units Shell Arrangement Prep. By MF
06 Ref. Dwg. App. By SS
07 P E R F O R M A N C E O F O N E U N I T
08 HOT SIDE COLD SIDE
09 Fluid Circulated FLASH STEAM CONDENSATE TURBINE CONDENSATE
10 Total fluid entering
11 Vapor Kg/Hr
12 Liquid Kg/Hr 1450 2100
17 Density Kg/M3 943 990
18 Viscosity - CST Liq..
19 Therm. Cond @ oC Kcal/hr.Mo Liq.
20 Mol. Weight 18 18
21 Sp.HeatKcal/Kg/Liq.Oc 1 1
22 Temperature In |Crit. Temp. 120 45
23 Temperature Out 47 95
24 Operating Kg/cm2 (G.) 1 2
25 Number of Passes Per Shell NA NA
26 Velocity Cross: Long: In Avg
27 Pressure Drop Allow 0.2 Calc: Allowed: 0.2
28 Fouling Resistance Hr. M2 oC/Kcal
29 Heat Exchanged - Kcal/Hr. 174000 L.M.T.D.
30 Transfer Rate - Service Kcal/hr.M2 oC Calc.
31 % Excess Surface - Required Actual
32 C O N S T R U C T I O N - E A C H S H E L L33 Design Pressure Kg/cm2 G. 6 6
34 Test Pressure Kg/cm2 G.
35 Design Temperature oC 160 110
36 Tubes na No. O.D. BWG Wall mm Length mm Pitch mm
37 plate MOCSS304 I.D. na O.D. na Thickness mm
38 Shell Cover na
39 Channel I.D. mm Channel Cover
40 Tube Sheets
42 Baffle Type Tube Supports
43 Tube To Tube Sheet Joint
44 Gaskets - MOC - Compressed Asbestos Fibre45 Connections - Shell In- " Out " Drain "
47 Corrosion Allowance - Hot Side mm cold Side mm
48 Code Requirements
49 Weights - Each Shell and Bundle Kg. Bundle Only Kg. Full of Water Kg.
50 REMARKS:
E-100
Date - 29.01.15
Sq.M.
COLD SIDE
TURBINE CONDENSATE
2100
990
1
45
95
2
Out
Calc:
9.2
Pitch mm