planning and system manual access professional - … and system manual access professional issue...

154
Planning and System Manual Access Professional Issue 2017

Upload: trinhdien

Post on 17-Apr-2018

215 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

Planning and System Manual Access ProfessionalIssue 2017

Page 2: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

2

Contents

1 Safety remarks 4

2 System description

Access in general 6

Fields of application 6

Performance features 6

System overview 7

3 System structure, conductor material and range

General planning information 8

Planning areas 8

Supply limits ATLC/NG 670-… 9

Permitted conductor material 9

Network LAN 10

Cabling structure/areas 10

Power over Ethernet (PoE) 10

Network characteristics 10

Cabling for indoor devices 11

Cameras 12

Pick-up range of the camera 13

Location of the video camera 13

4 System components

Overview 18

Door stations (outdoor/indoor area) 20

Access cameras 24

External cameras 25

Indoor stations (audio/video) 26

Accessory 28

Distribution components – Door controller 29

Distribution components – Active/passive system expansion 30

Distribution components – Line rectifiers 31

Distribution components – Transformers 32

Space requirements in distribu-tion boards/IT cabinets (19 inch) 33

Access server variants 34

Minimum requirements – Server hardware / Virtual machine 36

System conditions Access Professional 37

Additional requirements imposed on virtualization 37

Network security 38

Client-Software 38

App 39

Software integration for non-Siedle systems 39

Upgrade (server) 39

Access licences 40

Microsoft licences (CAL) 43

5 Function overview 44

6 Configuration – Access System

Models 48

Server administration – device parameters 51

Button functions 53

7 Access control through the Vario bus

Ranges in the Vario bus 60

Distribution components – Transformers 62

Modules 63

Distribution components – Server/controller 64

8 Access circuit diagrams

Overview 66

Switching outputs/inputs 68

8.1 Siedle Vario 70

8.2 Access custom-fit door loudspeaker 98

8.3 Siedle Classic 104

8.4 Siedle Steel 114

8.5 Camera connection 126

8.6 Storey call button 130

9 Commissioning and operation

Commissioning 132

Commissioning requirements 132

Commissioning instruction 132

Recommendation 133

Operating manual 133

Updates and maintenance 133

Maintenance contract 133

Page 3: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

3

RemarksThis document serves as a guide for the planning and technical implementation of the Siedle Access system. It is designed to provide an overview of the key points that need to be observed.

This document supplements and is supplemented by the Access server commissioning instructions.To supplement this system manual, you will find the latest edition in the download area of our website on www.siedle.com

For complex systems or special requirements, the technical consult-ants in Project Sales will be pleased to advise you.(For detailed information, see page 153)

We accept no liability for modi-fications, mistakes or printing errors.Modifications / additions, mistakes or printing errors do not form grounds for any claim to compensa-tion for damages.

10 Servicing

Service requirement 134

Warranty 134

Exchanging devices 134

Exchanging ATLM/ATLE 670-… 134

Exchanging a defective server AS 670-…/ASH 670-… 134

Update process 134

Start process 134

Initial commissioning/Login 135

Registration at the administrator user interface 135

LED displays 136

Terminal connections and meas-ured values 138

11 Glossary 140

12 Index

Access components 150

Access topics 151

13 Siedle service

Customer support and cus-tomer advice/Siedle centres 152

After-sales service 153

Page 4: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

4

1 Safety remarks

Electrical voltage

Mounting, installation and servicing work on electrical devices may only be performed by a suitably qualified electrician.Failure to observe this regulation could result in the risk of serious damage to health or fatal injury due to electric shocks.

Devices with 230 V connection In accordance with DIN VDE 0100 part 410, section 411.1.3 attention must be paid to ensuring a safe sepa-ration between system lines and the mains voltage; i.e. system and mains cores must not be permitted to touch! The system line cable (extra-low safety voltage) must be stripped back by the minimum possible.

Electrostatic charging

As a result of electrostatic charging, direct contact with the circuit board can result in destruction of the device. Direct contact with the circuit board must therefore be avoided.

• When working at the device, observe the remarks relating to mains cut-off.• Observe the DIN EN 60065 standard! When establishing the electronic connection, observe the requirements of VDE 0805 or EN 60950.• The building installation must include an all-pole mains switch with a contact separation of at least 3 mm.• Ensure maximum fusing of 16 A for the mains connection in the building installation.• When planning large-scale (complex) systems, the distributor space required for the switch panel mounting devices must be taken into consideration in the distributor planning process. • No external voltages >30 V AC/DC may be applied to system users.

Electrical distribution boards and IT cabinet systems

Please make sufficient provisions in the electrical distribution boards/IT cabinet system for later expansion, changes or subsequent disassembly (service/maintenance).

Plan the electrical distribution board/the IT cabinet system so that the heat generated by all installed com-ponents is adequately dissipated and cannot impair any functions or cause damage to the components or infra-structure at the installation site.

During planning, take the applicable legal provisions, standards, directives and safety instructions for the opera-tion/installation site into account.

All system components which are designed for/suitable for installation in an electrical distribution board or in an IT cabinet system/housing may only be installed in the permitted installation position according to the enclosed product information.If system components are operated in improper installation positions or with improper operating parameters (e.g. excessive ambient tempera-ture), this will render their warranty rights void in the event of service.

Page 5: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

5

Legal notice Photographs of individuals taken without their knowledge may not be published or stored in publicly acces-sible video memory facilities.Individuals who have been photo-graphed without their knowledge are entitled to request that pictures be deleted based on the right of persons to their own likeness. Never store pictures of persons you do not know in social networks or send them by email to others/public groups. This will infringe their per-sonal rights.If stored images are used as part of private / criminal law proceedings or in a police investigation, this requires prior clarification with a lawyer or the responsible police authority. Photographs of individuals taken without their knowledge may not be published or stored in publicly acces-sible video memory facilities.Individuals who have been photo-graphed without their knowledge are entitled to request that pictures be deleted based on the right of persons to their own likeness. Never store pictures of persons you do not know in social networks or send them by email to others/public groups. This will infringe their per-sonal rights.If stored images are used as part of private / criminal law proceedings or in a police investigation, this requires prior clarification with a lawyer or the responsible police authority.The legally admissible operation and installation of this device and all its system components (hardware and software) are the responsibility of the user and not of the device manufacturer.

Protect your network! Only use up-to-date components and terminals in the network in line with the latest state of the art. Regularly update the operating sys-tems of all components and termi-nals. Exchange obsolete components and terminals for up-to-date models. Use professional protective software (antivirus, firewall, …) in all termi-nals. Issue secure passwords. Secure your network with the highest secu-rity standards available in the net-work. Protect your network against unauthorized attack from inside and outside.

Protect your property! The Siedle App can be used from any location as a door release! Keep smartphones/tablets on which the Siedle App is activated safe from theft. Protect these devices against unauthorized usage with a code/password/fingerprint. Always use the latest protection mechanisms avail-able for your smartphone/tablet.

Page 6: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

6

Access in general Siedle Access is a server-based IP system for building communication. It offers the whole breadth of Siedle communication system functionality, from the speech or video connec-tion through concierge functionality to complex switching and control functions. Access works in its own IP network.Central management on the Access server permits configuration and administration both over the web browser and remotely. In addition, it facilitates system upgrading by adding and exchanging devices or licence models (e.g. function licences, licences for the use of external makes such as VoIP tel-ephones).The system utilizes the network protocols TCP/IP and UDP, as well as SIP for internet telephony (VoIP), extended to include an access-specific data protocol. The audio encoding standard (G.711) and video encoding standard (H.264) guarantee high picture and tone quality with minimal network loading.

Fields of application Projects with• a large number of users (door stations and/or indoor devices) and long distances• stringent demands on audio and video transmission• several (also geographically) sepa-rate building sections• concierge and surveillance func-tions• heterogeneous utilization (private and commercial mixed use)• fundamental requirement for structured cabling and IP technology

2 System description

Performance features Access offers• Simple planning and installation in conformity with standards• PC-based one-man commissioning• Use of door stations, indoor sta-tions, software clients or apps• Up to 320 users and 25 parallel video and speech channels (full-duplex voice connections) per Access server• Worldwide accessibility with secure door call via Siedle app on iPhone or iPad• An efficient PC-based concierge workstation with video surveillance function• Server for central system manage-ment and update function• Indoor devices that are supplied via PoE (Power over Ethernet) according to IEEE802.3af• Extensive audio/video communica-tion, control and security functions in and outside the Access system• Connection of different commu-nication and control platforms (VoIP, KNX, etc.)• System can be linked to public net-work telephony and telephone sys-tems conforming to the SIP standard• Connection of selected third-party hardware (VoIP TC systems, VoIP telephone, IP cameras (only for app), KNX gateways)• Integration of SIP audio, SIP video and a/b telephones• Integration of external cameras• Intercom functionality• Function extensions via optionally available licences• Call rerouting, call forwarding and call follow-me function• Call differentiation in terminals• Door call via call display or code lock keypad• Storey door loudspeaker (with and without video) and storey door release• Display of messages, statuses, or arriving calls in plain text on devices with displays• Scan mode for connected cameras• Optional group formation (e.g. for announcements)

• Call storage facility with call list and video memory• Polyphonic ringtones

Remarks From Access V 3.1.0, the inte-gration and operation of a building automation server (JUNG Facility Pilot Server) is possible using the Access Video Panel. Please note that the building automation server (JUNG Facility Pilot Server) is not a constituent part of the Siedle Access system. Advisory services and the sale of hardware and licences take place exclusively through ALBRECHT JUNG GmbH & Co. KG.

Page 7: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

7

ATLC/NG 670

ASHT

10:1012 1 20.05.2013Start 08:00 | 16.12.2014

AVP

AHTV AHF AHFV

Router

Internet

Internet

Internet

iPhone

iPad

iPad

iPhone

Router

Internet

ASHT

ASC

iPad

iPhone

Public mobil network

Public WLAN

Local network

Local telephone networkLocal Access network

Door station

Access serverSwitch

Switch

SIP telephone SIP telephone SIP telephone SIP telephone SIP telephone

SIP telephone system

Door release

WLAN

WLAN

Access gateway

Switch Customer server(e.g. mail server)

3G / 4G

System overview

Page 8: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

8

3 System structure, conductor material and range

General planning information The basis for planning an Access system is an IP network configured in accordance with specifications for creating structured cabling (as described under Network cabling).The purpose of the Access security concept is to ensure that network cabling terminates not outside the door but with the ATLC/NG 670-… Consequently, the door connection (as described under cabling in the door area) is not a constituent part of the IP network.For positioning of the Access devices and network components, it is advis-able to provide a construction plan. This should take into consideration the length restrictions of the con-nection types such as copper and optical fibres. The space requirement of network components and Siedle devices must be determined and taken into consideration. Siedle recommends drawing up a schematic drawing of the network structure and the used Siedle devices.

ATLC/NG 670-… ATLC/NG 670-…(+ NG 602-…)

max. 10 m

Door station

Camera

Door area

Network LAN

Range depends on the installed conductor material.

Network LAN

Door release (Tö)

Planning areas Generally speaking, a distinction is drawn between the door area and the protected local area network (LAN).

Door area The installation for the door station is referred to as the door area. If cor-rectly installed, this area is protected from unauthorized access. From the outside, it is not possible to access the network.

Logical and self-explanatory names should be assigned to the various devices, for example FL1AP5 for 1st floor, apartment 5. All cable seg-ments between active components should be listed in an index showing their name, cable length and cable type.In order to permit correctly con-trolled server shutdown, we recom-mend including a UPS (uninter-ruptible power supply) unit in the planning.

Cabling in the door area The IP network terminates with the ATLC/NG 670-… To protect against unauthorized access, the ATLC/NG 670-… must be accommodated without fail inside the building.The cabling from the ATLC/NG 670-… to the door station is executed in the conventional way. Every door station/independent camera is installed in the system with its own ATLC/NG 670-…The cabling between the door release and ATLC/NG 670-… should be tamper-proof with a separate line (direct laying).If an external camera is used, the maximum distance between AIVS 670-… and the camera is 10 m. The AIVS 670-… requires a video input signal of 1 Vss.The following conductor materials with suitable maximum ranges have been officially approved for wiring between ATLC/NG 670-… and the door station:

Page 9: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

9

Permitted conductor material

Cable type Diameter Maximum range

Telecommunications installation cable(Pair-twisted)

J-Y(St)Y… dia. 0.8 mm 200 m

J-Y(St)Y… dia. 0.6 mm 100 m

Telecommunications outdoor cable (Quad-twisted)

A-2Y(L)2Y… dia. 0.8 mm 200 m

A-2Y(L)2Y… dia. 0.6 mm 100 m

Network cable(Pair-twisted)

Cat. 5 AWG22… dia. 0.644 mm 120 m

Cat. 5 AWG23… dia. 0.573 mm 90 m

Cat. 5 AWG24… dia. 0.511 mm 80 m

Cat. 5 AWG26… dia. 0.405 mm 50 m

Terminals Cable type – Pair-twisted Cable type – Quad-twisted

ATLC/NG 670-0 Core Twin core Location Core Twin core Bundle

S1 a1 1

a1

1S2 b b

S3 a2 1

a2

S4 b b

D1 a3 1

a3

2D2 b b

V1 a4 1

a4

V2 b b

Depending on the cable type, pair-twisted or quad-twisted, we rec-ommend the following connection methods for the cabling between the door station and ATLC/NG 670-0:

Supply limits ATLC/NG 670-…

Siedle Vario Video door stations Audio door stations

Standard with COM 611-…

with DRM 612-…

Standard with COM 611-…

with DRM 612-…

ACM 67x-… 1 1 1 - - -

ATLM 670-… 1 1 1 1 1 1

COM 611-… - 1 - - 1 -

DRM 612-… - - 1 - - 1

BTM 650-… 10 1 1 26 12 12

Siedle Classic/Steel

ACM 67x-… 1 1 1 - - -

CATLE/SATLM 670-… 1 1 1 1 1 1

COM 611-… - 1 - - 1 -

DRM 612-… - - 1 - - 1

Call buttons 20 1 1 60 30 30

Page 10: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

10

Network LAN The requirement for integration of an Access system is a network infra-structure created in accordance with the stipulations for generic cabling (from Category 5).Rules for generic cabling are set out in various standards:• DIN 50173-1 General requirementsFor individual building types, the fol-lowing standards apply in addition:• DIN 50173-2 (ISO/IEC 11801) for office buildings• DIN 50173-3 (ISO/IEC 24702) for industrially used locations• DIN 50173-4 (ISO/IEC 15018) for apartmentsInternationally, the ISO/IEC standards apply.

Cabling structure/areas The cabling is broken down into 3 areas.

Primary area • Fibre optic cables• Cabling between individual buildings and/or within buildings between several main building dis-tributors.• In the case of copper wire con-nections, adequate equipotential bonding must be guaranteed.

Secondary area • Fibre optic cables• The storeys are networked by means of storey distributors. Both fibre optic and copper connections can be used. This is dependent upon the switches used and their distance from the main distributor/switch.

Tertiary area • Twisted pair for fixed installation plus patch cable for cabling from the network junction box to the terminal.

ATLC/NG 670

ServerSwitch

Door station

Primary area

Tertiary area

Seco

ndar

y ar

ea

Door release (Tö)

3 System structure, conductor material and range

Network characteristics Access system• Maximum of 50 ms delay in one direction (one way delay)• Maximum of 100 ms total delay• Packet loss < 1%• Maximum of 20 ms jitter

Power over Ethernet (PoE) The supply for the indoor stations must be ensured by the customer via PoE. Depending on the network infrastructure, the decentral PoE supply of individual devices can take place with PoE injectors, and the central PoE supply of several devices can take place with PoE-capable routers/switches. Routers/switches used must be PoE-capable according to IEEE802.3af.

Page 11: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

11

Cabling for indoor devices All indoor devices are always con-nected via an RJ45 8/8 (or RJ45 socket modules 8(8)) network socket. This is divided into two sockets. The left-hand socket is reserved for the network (LAN area). The right-hand socket is independent of the network and is used for connecting other control elements permitting additional uses.Supplementary functions such as a storey call button are also connected via the RJ45 network socket (right-hand socket/side) or the RJ45 socket modules 8(8).The range between ERT and the indoor device is max. 50 m (Cat 5 AWG22).The Access indoor devices can be installed without problems using standard RJ45 flush mounting net-work junction boxes.In this case, simply install the net-work junction box without the frame and panel. The Siedle indoor device can be mounted above the junction box and connected to the network with a plug-in connector.

If there is no flush mounted network socket at the required mounting height due to circumstances on site, the indoor call station can be surface mounted with the AZA 870-… In this case, the connection from the indoor call station to the network is established using a patch cable (not provided).

If the indoor call station is intended for use as a table-top unit, the device can be converted using the AZTV 870-… with 3 metre long con-necting cable.

165

cm

Eye level

Junction boxRJ45

Installation with patch cable

150

cm

165

cm

Eye levelJunction boxRJ45

Installation on flush mounted junctio box

Ideally, an RJ45 flush mounted junc-tion box should be positioned at the mounting height for the indoor device (display height less 15 cm).

Mounting with Access surface mounting accessory AZA 870-… and patch cable provided on site.

Page 12: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

12

3 System structure, conductor material and range Cameras

External cameras Audio door station with external analogue camera: For the external camera, an AIVS 670-… and a matching separate power supply (e.g. NG 602…) is required.

Separately operated external ana-logue camera: One AIVS 670-… and one ATLC/NG 670-… are required for each external analogue camera.

25x23x2

2Tö

AIVS 670

ATLC/NG 670-…NG 602-…

Door stationCamera

LAN

24x23x23x22 2

AIVS 670 AIVS 670

ATLC/NG 670-…ATLC/NG 670-…(NG 602-…)

ATLC/NG 670-…(NG 602-…)

Door stationCamera 1 Camera 2

LAN

If the camera used cannot be oper-ated with 48 V DC, an additional power supply (e.g. NG 602-…) must be selected.

The camera is connected to the ATLC via the AIVS.

The camera is connected to the ATLC via the AIVS.

Page 13: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

13

General Video cameras operating with the Vario door loudspeaker or exter-nally in the background provide an unobtrusive method of surveillance in the entrance area. Call, speech and door release operation of the door station. The visitor appears on screen at one or more of the video call stations.Possible applications include single and multiple family homes, private/commercial premises, practices and surgeries, administrative buildings etc.Other video components for special applications can be combined with our devices on request.

Location of the video camera Selection of the most suitable camera and its location is decisive to ensure good picture quality. The camera must not be directed towards:

• direct backlight• direct sunlight• very bright image backgrounds• highly reflective walls opposite the camera• lamps or direct light sources

Pick-up range of the camera

Diagram showing the pick-up range of external camera CE 600-… with image pick-up chip 1/3".

If the range of a camera module is not sufficient, external cameras such as the CE 600-… or CE 950-… can be used.

Object distance in m (h)

Obj

ect

wid

th in

m (a

)

12.00

10.00

8.00

6.00

4.00

2.00

0.00

3.8

mm

5.0

mm

9.5 mm

Page 14: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

14

Diagram showing the pick-up range of external camera CE 950-… with image pick-up chip 1/4".

Object distance in m (h)

Obj

ect

wid

th in

m (a

)

3.8

mm

5.0 m

m

8.0 mm

45.6 mm

12.00

10.00

8.00

6.00

4.00

2.00

0.00

Diagram pickup rangeCamera ACM 670-… with image pick-up chip 1/3".

Pick-up angle of the camera module ACM 670-…The adjustment range of the ACM 670-… is indicated by shading.

Object distance in m (h)

Obj

ect

wid

th in

m (a

)

12.00

10.00

8.00

6.00

4.00

2.00

0.00

AC

M 6

70

2.9

mm

50 cm

86 c

m10

6 cm

160

cm

214

cm

appr. 60°

113 cm

50 c

mappr. 80°

3 System structure, conductor material and range Pick-up range of the camera

Page 15: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

15

The picture excerpt visible on the display is mechanically set on the ACM 670-… camera by max. 30°.

Diagram pickup rangeCamera ACM 673-… with image pick-up chip 1/3".

Pick-up angle of the camera module ACM 673-…

50 cm

114

cm10

3 cm

217

cm

160

cm

ca. 100°

2 4 6 8 10 12

Object distance in m (h)

Obj

ect

wid

th in

m (a

)

12.00

10.00

8.00

6.00

4.00

2.00

0.00

2.1

mm

205 cm

50 c

m

appr. 130°

Page 16: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

16

The ACM 673-… camera transmits the entire recorded video image.

Diagram pickup rangeCamera ACM 678-… with image pick-up chip 1/3".

Pick-up angle of the camera module ACM 678-… in full screen mode.

ca. 135°

160

cm

50 cm

234

cm

43 c

m

277

cm

2 4 6 8 10 12

12.00

10.00

8.00

6.00

4.00

2.00

0.00

1.4

mm

Object distance in m

Obj

ect

wid

th in

m

appr. 165°

760 cm

50 c

m

3 System structure, conductor material and range Pick-up range of the camera

Page 17: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

17

Select the picture excerpt based on the existing mounting situation.

The pick-up angle of camera module ACM 678-… can be adjusted depending on the mounting situ-ation.Required picture excerpt from the camera view (1 to 9) or full screen (0).

Picture excerpt (1–3) top camera alignmentPicture excerpt (4–6) central camera alignmentPicture excerpt (7–9) bottom camera alignment

70° 70° 70°

160

cm

160

cm

160

cm

50 cm 50 cm 50 cm

277

cm

125

cm 195

cm

124

cm

43 c

m

167

cm

70 c

m

124

cm

1 2 3

456

7 8 9

Page 18: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

18

4 System components Overview

* Can also be used for customer’s existing door stations/letterbox sys-tems.

Door stations (outdoor/indoor area) (Possible designs: Vario/Classic/Steel)• ACM 670-…Access camera 80 for Siedle Vario

• ACM 673-…Access camera 130 for Siedle Vario

• ACM 678-…Access camera 180 for Siedle Vario

• ATLE 670-… *Access custom-fit door loudspeaker incl. Bus call button matrix

• ATLM 670-…Access door loudspeaker module

• BRMA 050-… *Bus call button matrix

• BTM 650-01 to -04Bus call button module

• COM 611-…Code lock module

• DRM 612-…Display call module

• ELM 611-…Electronic-key reading module

• FPM 611-…Fingerprint module

• PME…Mail notification system(Classic/Steel)

• TÖ 61x-…Door release (DIN left or right)

• VTMC 640-…Flush-mounted colour camera

External cameras/ Surface-mounted components • AIVS 670-…Access Interface analog-video standard

• CE 600-…External colour CCD video camera for external mounting

• CE 950-…External colour CCD video camera for external mounting

Indoor stations (audio/video) • AHF 870-…Access handsfree telephone

• AHFV 870-…Access video handsfree telephone

• AHT 870-…Access in-house telephone

• AHTV 870-…Access video in-house telephone

• AVP 870-…Access video panel

Upgrade (audio indoor station) • AUV 870-…Access for video upgrade

Accessory • AZA 870-…Access surface-mount accessory

• AZIO 870-…Access input/output accessory

• AZTV 870-…Access table-top accessory

• AZTVP 870-…Access table-top accessory

• ZRE 600-…19 inch rack mounting accessory

Distribution components • ANG 600-…Access line rectifier

• ATLC/NG 670-…Access door loudspeaker controller with line rectifier

• ATLCE 670-…Access door loudspeaker controller extension

• AVA 670-…Access video decoupler

• ECE 602-…Entrance controller extension

• EC 602-…Entrance controller

• NG 602-…Line rectifier

• TCIP 603-…Door controller IP

• TCIP SRV 603-…Door controller IP server

• VNG 602-…Video line rectifier

• TR 602-…Transformer

• TR 603-…Transformer

• ZWA 640-…Western socket accessory

Page 19: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

19

Client-Software • ASC 170-…Access Software Concierge

• ASHT 170-…Access Software In-house telephone

App • Siedle app for Access

Software integration for non-Siedle systems • ASM 170-…Access software module

Access user licence packages (Server operation) • APR 670-0 10 Access Professional

• APR 670-0 20 Access Professional

• APR 670-0 40 Access Professional

• APR 670-0 80 Access Professional

• APR 670-0 160 Access Professional

• APR 670-0 320 Access Professional

Optional Access application licences (Models) • ALFA 270-…Access licence for external audio device

• ALFS 270-…Access licence for external smart-phone

• ALFT 270-…Access licence for external tablet

• ALFV 270-…Access licence for external video device

• ALKNX 270-… <50Access licence for KNX connection

• ALKNX 270-… <300Access licence for KNX connection

• ALKNX 270-… >300Access licence for KNX connection

• ALT 270-…Access licence for telephony con-nection

• ASC 170-…Access Software Concierge

• ASHT 170-…Access Software In-house telephone

• ASM 170-…Access software module

Access server variantsSoftware variant• Access Professional V 4…

Hardware variant • ASH 670-04 MAccess server hardware M

• ASH 670-04 SAccess server hardware S

Upgrade (server) • ASU 670-04Access server upgrade package

Network security – active components for physical network separation • AGW 670-…Access gateway

Page 20: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

20

Siedle Vario From the door bell to the switching and control centre, modern building communication has a lot to offer. Visitor information and guidance, receiving mail, lighting, security, access control and image projection: The requirements are many and varied. Siedle’s solution is a simple one: The modular principle.Siedle Vario is unmatched in its flex-ibility. As an open-ended, modular system, it fits in with the building owner’s requirements, the design specifications of the architect as well as building constraints. The Vario system design ensures that any com-bination of functional modules com-plies with the most stringent stand-ards of both form and function.Top-quality materials such as alu-minium or weather and UV-resistant polycarbonate guarantee reliable performance over a long service life.The same high standards apply to the planning and processing stage. Thanks to pre-installation, mounting aids and installation compartments, Siedle Vario is quickly and economi-cally planned and installed.

Siedle Classic A metal range with a system:Siedle Classic provides an attractive entry into the use of premium mate-rials at the threshold. The product line is a variable system with a broad range of functions and an enlarged application spectrum. Siedle Classic provides everything you could conceivably need at the front door. Alongside intercom system with bell, access control, the letterbox and movement sensor module supple-ment the audio and video communi-cation functions.Siedle Classic is available in various standard systems. These are designed to cover the majority of door communication requirements. We are able to supply bespoke solu-tions to address special requirements in terms of design and functionality.

Siedle Steel Door stations from the Siedle Steel range are individually produced and supplied as a fully functional com-plete unit. So when planning a new installation, all you need to decide is which type of installation system you require. We take charge of collating all the necessary components and equipping the door station.

4 System components Door stations (outdoor/indoor area)

Page 21: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

21

ATLM 670-0 Access door loudspeaker module in 611 Vario design.Complete module with loudspeaker, microphone and light button with LED illuminated light symbol.Up to max. 48 call button modules can be connected in any optional combination, allowing up to max. 192 users.Acoustic feedback when actuating the call button at the BTM 650-01 to -04 optional.Ambient temperature: –20 °C to +55 °CProtection system: IP 54Height of structure (mm): 9Dimensions (mm) W x H x D: 99 x 99 x 35

The ATLM 670-0 draws 48 V DC over terminals S1-S4 from the ATLC/NG 670-0. This converts the voltage into 15 V DC with max. 400 mA and outputs this to terminals b1 and c1 of the terminal block.

ATLE 670-0 Access custom-fit door loudspeaker with bus call button matrix for mounting in a loudspeaker compart-ment, door constructions, letter-boxes etc.12 of the client’s own call buttons can be directly connected at the bus call button matrix BRMA 050-…Control output for external camera, connection of existing buttons via BRMA 050-…Max. 16 BRMA 050-… can be con-nected to 1 ATLE 670-…Protection system: Dependent on the mounting conditionsDimensions (mm) W x H x D: ATLE 670-0 124 x 60 x 31, BRMA 050-01 53 x 100 x 17Dimensions housing (mm) W x H x D: 100 x 60 x 31

BRMA 050-01 Bus call button matrix for the con-nection of existing call buttons to the custom-fit door loudspeaker BTLE 050-…/ATLE 670-…Max. 160 call buttons can be con-nected. However, a bus call button matrix BRMA 050-… is required for each started group of 12 call but-tons.Max. 14 BRMA 050-… can be con-nected to 1 BTLE 050-…Max. 16 BRMA 050-… can be con-nected to 1 ATLE 670-…

The connection of the call buttons for Siedle Classic is described in the call button wiring diagram.(For detailed information, see page 104)

Page 22: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

22

DRM 612-01 Display call module as an input device with 4-line display for placing door calls.Indication of names in the display in alphabetical order. The DRM 612-… can also be used in combination with the COM 611-… in order to display the input via the DRM 612-…Operating voltage: 12 V ACOperating current: max. 200 mAProtection system: IP 54Ambient temperature: –20 °C to +55 °CDimensions (mm) W x H x D: 99 x 99 x 27

COM 611-02 Code lock module as an input device for the placement of door calls and control functions in conjunction with Access and the Siedle access control system.• With keypad for making calls or• For controlling in conjunction with the Easikey controller EC 602-…• C button for cancelling incorrect inputs• DR button for direct door release via the EC 602-…Operating voltage: 12 V ACOperating current: max. 140 mAProtection system: IP 54Ambient temperature: –20 °C to +55 °CDimensions (mm) W x H x D: 99 x 99 x 27

BTM 650-01 to -04 Bus call button modules BTM 650-… with 1, 2, 3 or 4 call buttons. The BTM 650-… is connected to the ATLM 670-… via ribbon cable.Nameplate size (mm) W x H: 65 x 19.5Call button (mm) W x H: 24 x 24Protection system: IP 54Ambient temperature: –20 °C to +55 °CDimensions (mm) W x H x D: 99 x 99 x 27

4 System components Door stations (outdoor/indoor area)

1 2 3

4 5 6

7 8 9

F 0 COK

Page 23: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

23

PME-… Mail notification system for signal-ling incoming post on any Access indoor station.The mail notification system must be taken into account during planning for the letterbox system, as it is no longer technically possible to retrofit it later on.To use this function, the relevant indoor station must be configured via the Access administration inter-face.

TÖ-… (Door release) Siedle door release units are high-resistance > 20 Ohm and provide operating reliability even over long ranges.Standard commercially available door release units 8 – 12 V AC, 20 Ohm can be connected.

AIVS 670-0 Access analog video standard inter-face in surface-mount housing for connection of an analog camera to the ATLC 670-…Following a door call, the picture from the analog camera automati-cally appears on the Access indoor call station. Manual selection of the door is also possible. The camera cannot be controlled. Protection system: IP 65Ambient temperature: –20 °C to +55 °CDimensions (mm) W x H x D: 122 x 122 x 56Dimensions housing (mm) W x H x D: 93 x 93 x 56

AIVS 670

Access Interface Analog-Video Standard

Page 24: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

24

ACM 673-01 Access camera 130 for Siedle Vario with automatic day/night switchover (True Day/Night) and integrated infrared lighting. Horizontal/vertical pick-up angle: appr. 130°/100°Colour system: PALImage pick-up: CMOS sensor 1/3" 756 x 504 PixelResolution: 550 TV linesLens: 2.1 mmContinuous operation: suitable2-step heating: IntegratedProtection system: IP 54, IK 10Ambient temperature: –20 °C to +55 °CHeight of structure (mm): 15Dimensions (mm) W x H x D: 99 x 99 x 41

ACM 678-01 Access camera 180 for Siedle Vario with automatic day/night switchover. Horizontal/vertical pick-up angle: appr. 165°/135°Colour system: PALImage pick-up: CMOS sensor 1/3" 1280 x 960 PixelResolution: 600 TV linesLens: 1.4 mmContinuous operation: suitable2-step heating: IntegratedProtection system: IP 54, IK 10Ambient temperature: –20 °C to +55 °CHeight of structure (mm): 15Dimensions (mm) W x H x D: 99 x 99 x 41

4 System components Access cameras

ACM 670-02 Access camera 80 for Siedle Vario with automatic day/night switchover (True Day/Night) and integrated infrared lighting. Horizontal/vertical pick-up angle: appr. 80°/60°Colour system: PALImage pick-up: CMOS sensor 1/3" 728 x 488 PixelResolution: 500 TV linesLens: 2.9 mmMechanical adjustment range: 30° horizontal/vertical2-step heating: IntegratedProtection system: IP 54, IK 10Ambient temperature: –20 °C to +55 °CHeight of structure (mm): 32Dimensions (mm) W x H x D: 99 x 99 x 58

Page 25: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

25

VTMC 640-01 Flush-mounted colour camera with automatic day/night switchover and integrated infrared lighting. Horizontal/vertical pick-up angle: appr. 65°/53°Colour system: PALImage pick-up: CCD sensor 1/3" 752 x 582 PixelResolution: 470 TV linesLens: 3.7 mmContinuous operation: suitableHeating: 12 V AC max. 50 mAVideo output: 1 Vss at 75 OhmOperating voltage: 20–30 V DCOperating current: max. 105 mAProtection system: IP 54Ambient temperature: –20 °C to +40 °CDimensions (mm) W x H x D: 99 x 99 x 26

This analogue camera is connected to the ATLC 670-… door con-troller via the Access AIVSE 670-… analogue-video standard interface mounting.An additional power supply is required for the camera heating (e.g. TR 603-…).

CE 950-01 Colour CCD video camera external mounting with automatic day/night switchover (True Day/Night) and inte-grated infrared lighting. Horizontal pick-up angle: ca. 45,6°–4,0°Colour system: PALImage pick-up: CCD sensor 1/4" 976 x 582 PixelResolution: 700 TV linesLens: 3.8–45.6 mmMechanical adjustment range: 180° horizontal/verticalContinuous operation: suitableVideo output: 1 Vss at 75 OhmOperating voltage: 20–50 V DCOperating current: max. 500 mAProtection system: IP 67Ambient temperature: –20 °C to +50 °CDimensions (mm) W x H x D: 100 x 108 x 267

CE 600-01 Colour CCD video camera external mounting with automatic day/night switchover (True Day/Night) and inte-grated infrared lighting. Horizontal pick-up angle: appr. 81.2°–22.5°Colour system: PALImage pick-up: CCD sensor 1/3" 976 x 582 PixelResolution: 750 TV linesLens: 2.8–12 mmMechanical adjustment range: 160° horizontal/180° verticalContinuous operation: suitableVideo output: 1 Vss at 75 OhmOperating voltage: 20–50 V DCOperating current: max. 250 mAProtection system: IP 67Ambient temperature: –20 °C to +50 °CDimensions (mm) W x H x D: 75.3 x 76 x 218.5

External cameras

Page 26: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

26

AVP 870-0 Access video panel with touchscreen 17.8 cm for the Access system, made of high-grade plastic. The panel is a system product with a low-profile surface-mount housing for wall and table-top mounting. It provides ergonomically designed intuitive user prompting with gesture control.

The AVP 870-… can only be used in conjunction with Server Release V.2.1.0 and higher.On a change of release, additional costs could be incurred under certain circumstances.

With the functions calling, speech, vision, door release, light, remote switching and call silencing.Performance features:• Individual crafted design concept offering a wide choice of varied fea-tures and finishes• Display offers graphic scope for individual operation • 17.8 cm (7") touchscreen, resolu-tion 800 x 480 Pixel• Brilliant image reproduction• Excellent audio quality (dual loud-speaker technology)• Input for storey call• Output freely programmable• Additional inputs and outputs with Access input/output accessory AZIO 870-…• Call differentiation between door calls, storey calls, and internal calls• Switching functions• Video memory function• Can be used with table-top acces-sory AZTVP 870-… as a table-top device• Update capability using the Access server

Current consumption of the indoor station: PoE class 3Operating voltage: PoE in accord-ance with 802.3afAmbient temperature: +5 °C to +40 °CDimensions (mm) W x H x D: 202 x 202 x 30

AHTV 870-0 Access in-house telephone video with door release button and 7 additional buttons with 2-colour status LED. All buttons are freely programmable. The display shows the camera image and the graphic menu interface.With the functions calling, speech, door release, vision, light, remote switching and call silencing.Performance features:• Display 8.8 cm• Entrance for storey calls• Exit freely programmable• Call differentiation between door calls, storey calls and indoor calls• Switching functions• Status indications• Video memory function• Integrated 5-way control button• Can be used with table-top acces-sory AZTV 870-… as a table-top deviceCurrent consumption of the indoor station: PoE class 2Operating voltage: PoE in accord-ance with 802.3afAmbient temperature: +5 °C to +40 °CDimensions (mm) W x H x D: 106 x 278 x 51

4 System components Indoor stations (audio/video)

Page 27: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

27

AHT 870-0 Access in-house telephone with door release button and 7 additional but-tons with 2-colour status LED. All buttons are freely programmable. The display shows the graphic menu interface, but not a camera image. It is possible to upgrade to a fully functional video station.With the functions calling, speech, door release, light, remote switching and call barring.With the additional purchase of the AUV 870-… T, the AHT 870-… can be transformed into a fully valid video indoor device.Performance features:• Display 8.8 cm• Input for storey call• Output freely programmable• Call differentiation between door calls, storey calls, and internal calls• Switching functions• Status messages• Can be used with table-top acces-sory AZTV 870-… as a table-top deviceCurrent consumption of the indoor station: PoE class 2Operating voltage: PoE in accord-ance with 802.3afAmbient temperature: +5 °C to +40 °CDimensions (mm) W x H x D: 106 x 278 x 51

AHFV 870-0 Access handsfree telephone video with speech/control button, door release button and 7 additional but-tons with 2-colour status LED. All buttons are freely programmable. The display shows the camera image and the graphic menu interface.With the functions calling, speech, door release, vision, light, remote switching and call silencing. Performance features:• Display 8.8 cm• Entrance for storey calls• Exit freely programmable• Call differentiation between door calls, storey calls and indoor calls• Switching functions• Status indications• Video memory function• Integrated 5-way control button• Can be used with table-top acces-sory AZTV 870-… as a table-top deviceCurrent consumption of the indoor station: PoE class 2Operating voltage: PoE in accord-ance with 802.3afAmbient temperature: +5 °C to +40 °CDimensions (mm) W x H x D: 106 x 278 x 32

AHF 870-0 Access handsfree telephone with speech/control button, door release button and 7 additional buttons with 2-colour status LED. All buttons are freely programmable. The display shows the graphic menu interface, but not a camera image. It is pos-sible to upgrade to a fully functional video station.With the functions calling, speech, door release, light, remote switching and call barring.With the additional purchase of the AUV 870-… F, the AHF 870-… can be transformed into a fully valid video indoor device.Performance features:• Display 8.8 cm• Input for storey call• Output freely programmable• Call differentiation between door calls, storey calls, and internal calls• Switching functions• Status messages• Can be used with table-top acces-sory AZTV 870-… as a table-top deviceCurrent consumption of the indoor station: PoE class 2Operating voltage: PoE in accord-ance with 802.3afAmbient temperature: +5 °C to +40 °CDimensions (mm) W x H x D: 106 x 278 x 32

Page 28: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

28

AUV 870-0 T/F Access upgrade video subsequently enables the video function in an audio device.For the in-house telephone AHT 870-…, the AUV 870-0 T is required / for the handsfree telephone AHF 870-…, the AUV 870-0 F.

4 System components Accessory

AZTV 870-0 Access table-top accessory for Access in-house and handsfree telephones for conversion from wall mounted to table-top device, slip-proof console.Connecting cable: 2 x 8-core 3 m long with RJ45 plug

AZA 870-0 Access surface-mounting accessory for professional surface mounting of Access in-house and handsfree telephones.Comprises a connection adapter and 4 spacers. The raised height is increased by 8 mm.

AZIO 870-0 Access input/output accessory as circuit board for integration in an indoor unit with an additional input/output.Switching output:n.o. contact 30 V AC/DC, 1 ASwitching input for potential-free contacts (min. 20 V DC, 10 mA)

AZTVP 870-0 Table-top accessory for the video panel AVP 870-… for conversion from a wall to a table unit.Performance features:• Individual design concept with 3 design variants• Slip-proof table foot• Cable guide• 2 connecting cables with RJ45 plugConnecting cable: 2 x 8-core 3 m long with RJ45 plug

ZRE 600-0 19 inch rack mounting accessory for the Access Server S and the TCIP server. Comprising retaining plate including mounted handles and mounting accessories.Dimensions (mm) W x H x D: 483 x 88 x 132

TopOben

Page 29: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

29

ATLC/NG 670-0 Access door loudspeaker controller with line rectifier in switch panel housing as an interface for the con-nection and power supply of door components to the Access network.

Set consisting of ATLC 670-0 and ANG 600-0.

ATLC 670-0 Access door loudspeaker controller in switch panel housing as interface for connecting the door station to a network.Switch contact for door release and freely programmable switching input.Optional connection facility for a maximum of 3 extension modules ATLCE 670-…Supply via ANG 600-0Supply voltage 48 V DCOutput voltage: 10–16 VOutput current: max. 700/300 mA AC/DCContact type: Contact 30 V, 2 AProtection system: IP 20Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 6Dimensions (mm) W x H x D: 107 x 89 x 60

Distribution components – Door controller

ANG 600-0 Access line rectifier in switch panel housing for power supply e.g. to the ATLC 670-… with 230 V AC switching contact.Admissible switching output:• Light bulbs max. 1300 W• Fluorescent lamps max. 800 W• Twin fluorescent lamps max. 1200 W• Parallel compensated fluorescent lamps max. 400 WOperating voltage: 100–240 V AC, +/-10 %, 50/60 HzOperating current: 0.5–1 AOutput voltage: 48 V DCOutput current: 800 mAFusing: primary T 2 A, secondary short circuit proofContact type: changeover switch max. 250 V AC, 6 AProtection system: IP 20Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 6Dimensions (mm) W x H x D: 107 x 89 x 60

Page 30: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

30

ATLCE 670-0 Access door loudspeaker controller extension in switch panel housing with 4 outputs and 2 inputs.A maximum of 3 ATLCE 670-… units can be connected in series to an ATLC 670-… by means of ribbon cable.Protection system: IP 20Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 3Dimensions (mm) W x H x D: 53.5 x 89 x 60

AVA 670-0 Access video decoupler in switch panel housing. Permits the decou-pling of an analogue video signal from the Access system.Operating voltage: 10–50 V DCOperating current: max. 25 mAProtection system: IP 20Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 3Dimensions (mm) W x H x D: 53.5 x 89 x 60

ZWA 640-0 Western socket accessory for switch panel mounting. Integrated socket for 4/6/8-pin western plug.Connection by means of screw-type terminals.Protection system: IP 20Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 1Dimensions (mm) W x H x D: 18 x 90 x 60

4 System components Distribution components – Active/passive system expansion

DSC 602-0 Pilfer safeguard controller in a switch panel housing to control a maximum of 2 pilfer safeguard accessories ZDS 601-…Using 2 integrated buttons, the mounting frame can be locked and unlocked. An LED flashes to indi-cate that the release button at the DSC 602-… has been activated. It is only possible to lock the mounting frame after removing the Vario key.Operating voltage: 12 V ACOperating current: max. 100 mAProtection system: IP 20Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 3Dimensions (mm) W x H x D: 53.5 x 89 x 60

Page 31: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

31

VNG 602-02 Video line rectifier in switch panel housing for centrally supplying video door intercom systems or for sup-plying additional components (e.g. external camera).Operating voltage: 230 V AC, +/-10 %, 50/60 HzOperating current: 200 mAOutput voltage: 30 V DCOutput current: 1.1 AFusing: Si 1 T 200 mA, secondary side thermal fuseProtection system: IP 20Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 10Dimensions (mm) W x H x D: 180 x 89 x 60

NG 602-01 Line rectifier in switch panel housing for supplying additional components (e.g. external camera).Operating voltage: 230 V AC, +/-10 %, 50/60 HzTypical current consumption: 41 VAOutput voltage: 23.3 V DC, 12 V ACOutput current: 0.3 A DC, 1.6 A ACProtection system: IP 20Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 6Dimensions (mm) W x H x D: 107 x 89 x 60

Distribution components – Line rectifiers

ANG 600-0 Access line rectifier in switch panel housing for power supply e.g. to the ATLC 670-… with 230 V AC switching contact.Admissible switching output:• Light bulbs max. 1300 W• Fluorescent lamps max. 800 W• Twin fluorescent lamps max. 1200 W• Parallel compensated fluorescent lamps max. 400 WOperating voltage: 100–240 V AC, +/-10 %, 50/60 HzOperating current: 0.5–1 AOutput voltage: 48 V DCOutput current: 800 mAFusing: primary T 2 A, secondary short circuit proofContact type: changeover switch max. 250 V AC, 6 AProtection system: IP 20Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 6Dimensions (mm) W x H x D: 107 x 89 x 60

Page 32: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

32

TR 602-01Transformer in switch panel housing for supplying additional components (e.g. easikey controller for access control).Operating voltage: 230 V AC, +/-10 %, 50/60 HzOperating current: 170 mAOutput voltage: 12 V ACOutput current: max. 2.5 AFusing: Secondary side with thermal fuseProtection system: IP 20Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 6Dimensions (mm) W x H x D: 107 x 89 x 60

TR 603-0Transformer in switch panel housing for supplying additional components (e.g. mail notification system or door release via potential-free contact).Operating voltage: 230 V AC, +/-10 %, 50/60 HzOperating current: 100 mAOutput voltage: 12 V ACOutput current: max. 1.3 AFusing: Secondary side with thermal fuseProtection system: IP 30Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 3Dimensions (mm) W x H x D: 53.5 x 89 x 60

4 System components Distribution components – Transformers

Page 33: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

33

Space requirements in distribution boards/IT cabinets (19 inch)

Space required (height) in IT cabinet system/housing (19 inch)

Models Rack units (RU)

AGW 670-0 2

ASH 670-04 M 2

ASH 670-04 S * (2)

TCIP SRV 603-0* (2)

* with rack installation kit: ZRE 600-0 2

Please make sufficient provisions in the electrical distribution boards/IT cabinet system for later expansion, changes or subsequent disassembly (service/maintenance).All system components which are designed for/suitable for installation in an electrical distribution board or in an IT cabinet system/housing may only be installed in the permitted installation position according to the enclosed product information. If system components are operated in improper installation positions or with improper operating parameters (e.g. excessive ambient tempera-ture), this will render their warranty rights void in the event of service.During planning, take the applicable legal provisions, standards, directives and safety instructions for the opera-tion/installation site into account.

Space requirement in the distributor

Models Horizontal pitches (TE)

ANG 600-0 6

ASH 670-04 S * 3 x 12 TE

ATLC 670-0 6

ATLCE 670-0 3

ATLC/NG 670-0 2 x 6 TE

AVA 670-0 3

EC 602-03 6

ECE 602-0 3

NG 602-01 6

TCIP SRV 603-0 * 3 x 12 TE

TCIP 603-03 8

TR 602-01 6

TR 603-0 3

VNG 602-02 10

* with top hat rail mounting kit.Please ensure enough space is provided for service and maintenance.

Page 34: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

34

ASH 670-04 S Access Server hardware S for the IP-based building communication system Siedle Access Professional for up to 50 users. An Access user licence is required for the regular use of Access Server hardware.Version in a metal housing suitable for top hat rail mounting (space requirement distribution: 3 x 12 horizontal pitch units (TE)). Capable of integration in the existing IT landscape (with optional acces-sory ZRE 600-0 rack installation kit (486.6mm/19") – space requirement (height): 2 rack units (HE)). Scope of supply: Access Server hardware in desktop housing incl. pre-installed server operating system Windows Server 2012 R2 for Telecommunication and Access Professional with 30-day test licence as well as electrical con-necting cable and small mounting items for top hat rail mounting.Components:CPU: Intel Atom D510; 1.6 GHz Dual-CoreWorking memory: 2 GB DDR3Graphic: Intel GMA3150Hard disc: 320 GB SATA-IILAN: 2 x gigabitOperating voltage: 90–264 V AC, 47–63 HzTypical current consumption: max. 45 WHorizontal pitch (HP): 3 x 12Ambient temperature: +10 °C to +50 °CDimensions (mm) W x H x D: 328 x 88.8 x 201

ASH 670-04 M Access Server hardware M for the IP-based building communication system Siedle Access Professional for up to 320 users. An Access user licence is required for the regular use of Access Server hardware.Version in a housing for IT cabinet systems (482.6 mm / 19") – space requirement (height): 2 rack units (HE).Scope of supply: Access Server hardware in 19" housing incl. pre-installed server operating system Windows Server 2012 R2 for Telecommunication and Access Professional with 30-day test licence as well as electrical con-necting cable and small mounting items for installation in an existing 19" IT cabinet system.Components:CPU: Intel Xeon X3430; 2.4 GHz Quad-CoreWorking memory: 4 GB DDR3Graphics: Matrox G200eWHard disc: 250 GB SATA-IILAN: 2 x gigabitOperating voltage: 90–264 V AC, 47–63 HzTypical current consumption: max. 78 WAmbient temperature: +10 °C to +35 °CDimensions (mm) W x H x D: 463 x 88 x 460

4 System components Access server variants

Access Professional Access system software for installa-tion and operation on existing server hardware/virtualization with installed server operating system according to requirements. For regular operation of the Access system, an Access user licence for up to 320 users/devices must be purchased for a fee. The trial period for an Access system without a valid Access user licence ends after 30 days. In order to operate Access Professional correctly as a software variant, the provided server hardware/virtual machine and the network infrastructure must meet the minimum requirements of the Access system:• Processor output: min. Intel Xeon Quad Core Processor 64 Bit (from launch year 2014 or more recent)• Random access memory (RAM): at least 4 GB• Storage location (HD): at least 256 GB• Network connection (LAN): at least 1 x 1000 Mbit/s• Recommended number of line rectifiers: 2• Operating system: Microsoft Server 2012 R2 Standard or Datacenter (installation: Standard full installation -> Server with graphic user interface)• Role of the server operating system: optionally: DHCP server ser-vice, if no DHCP server is operated in the existing network.• Necessary DHCP options: Time Server, Log Servers, NTP Servers, Boot Server Host Name, Bootfile NameOptionally: Router (Default Gateway), Domain Name and DNS-Server

Page 35: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

35

A comparison of Access server variants

Access server variant Access Professional ASH 670-04 M ASH 670-04 S

Finish Software without server oper-ating system/virtualization

Hardware server + pre-installed Access Professional

Hardware server + pre-installed Access Professional

Access system version Access Professional V 4… Access Professional V 4… Access Professional V 4…

Possible number of users (User licences)

10–320 10–320 10–50

Possible number of com-munication connections (simultaneously)

25 25 10

Conditions • Hardware server• Server operating system (MS Server 2012 R2 Standard)• Microsoft .NET Framework 4.6.1 for Windows Server 2012 R2 (offline installer or web installer if internet connection exists).• Network/VLAN as required• Indoor stations with POE supply • Software clients/apps on terminals with network con-nection

• Network/VLAN as required• Indoor stations with POE supply • Software clients/apps on terminals with network connection

• Network/VLAN as required• Indoor stations with POE supply • Software clients/apps on terminals with network connection

As-delivered status • The Access server must be installed and commissioned.• For regular operation of the Access system, an Access user licence for up to 320 users/devices must be purchased for a fee. The trial period for an Access system without a valid Access user licence ends after 30 days.• The server hardware/virtu-alization and server operating system must be provided by the customer and must be available.• Microsoft licences: Please check whether any Microsoft server access licences (Client Access License – CAL) are required by the customer for operation of the Access users, or whether these already exist. (For detailed informa-tion, see page 43)

• The Access server is installed ready for operation and prepared for commissioning by the customer.• An Access user licence is required for the regular use of Access Professional. The Access user licence allows Siedle Access Professional to be enabled and used in Version V 4.0.0 for up to 320 users/terminals per system (optionally inclusive of licensed hardware indoor stations/door stations and/or optional hardware and software terminals to be licensed). Access user licences can be purchased for 10, 20, 40, 80, 160 or 320 users/terminals and combined as required. The trial period for an Access system without a valid Access user licence ends after 30 days.• Optional application licences enable the use of addi-tional performance features.

RemarkThe standard password for the server operating system of a Access Server Hardware (from ASH 670-04…) is: SiedleAccessMain2015

Please change the password on initial commis-sioning, taking note of the security instructions.

Maintenance contract Maintenance contracts for the Siedle Access system can be purchased both through the Siedle Project Sales and through an Access Certified Partner (ACP).(For detailed information, see page 133)

Page 36: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

36

Minimum requirements – Server hardware / Virtual machine *

Possible number of users (User licences)

320 50

Processor output min. Intel Xeon Quad Core Processor 64 Bit (from launch year 2014 or more recent)

min. Intel Atom D510; 1.6 GHz dual-core *

Random access memory (RAM) at least 4 GB at least 2 GB

Storage location (HD) at least 256 GB

Network connection (LAN) at least 1 x 1000 Mbit/s

Server operating system/software

Operating system Microsoft Server 2012 R2 Standard or Datacenter (installation: Standard full installation -> Server with graphic user interface)

Role of the server operating system optionally: DHCP server service, if no DHCP server is operated in the existing network.

Other server services optionally: NTP server

Necessary DHCP options Time Server, Log Servers, NTP Servers, Boot Server Host Name, Bootfile NameOptionally: Router (Default Gateway), Domain Name and DNS-Server

Access system version Access Professional – from Version 4.0.0

Access licences For regular operation of Access Professional, an Access user licence must be purchased against a fee.Optional application licences enable the use of additional performance features.

Network connection

Network Own physical network from CAT-5 and optionally with modified VLAN with Quality of Service (IEEE802.1p)

Transmission speed 100 MBit/sec (End devices)1000 MBit/sec (Server hardware)

Internet protocol IPv4

Multicast capability(only if you wish the video signal to be transferred in the network as a multicast stream. As an alterna-tive, the unicast operation mode can be used. With unicast, every video stream is separately generated and can cause very high network capacity utilization where there are high number of users with approx. 1 MBit per user.)

Throughout the entire network

Distribution list The use of switches is a requirement.

Power over Ethernet (PoE) Access indoor stations require PoE-capable switches or PoE injectors in compliance with IEEE802.3af

4 System components A comparison of Access server variants

Page 37: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

37

System conditions Access Professional In order to operate Access Professional correctly as a soft-ware variant, the provided server hardware/virtual machine and the network infrastructure must meet the minimum requirements of the Access system

Remarks• In order to work with Access Server Administration, you need an PC with the latest version of the web browser Mozilla Firefox.If you use a different web browser to the Mozilla Firefox, display errors can occur.• Two network sockets are affixed to the back of the Access server hardware (Service and Access). For linking the Access devices to the Access network, the Access socket must be used.

Notice on the scope of supply The Access server hardware is delivered as standard with the fol-lowing additional software tools and releases:• 7-Zip (x64)• Firefox• Notepad++• Putty• Wireshark• WinPcap• Remote desktop release

The listed files and programs are required for configuration and servicing purposes and should only be used by specialist and servicing personnel.The Access system (software variant) is delivered without these additional software tools and releases.

Additional requirements imposed on virtualization • For virtualization, from VMware  vSphere 6 upwards a virtualization solution configured for server sys-tems must be used.• The minimum requirements imposed on the virtual machine are the same on principle as server hardware provided by the customer for up to 320 users. With the virtual machine, remember that at least 2 virtual and separate processor units (CPUs) must be made available.• If virtualization is used, the host (physically present server on which the virtual machine is operated) must have sufficient performance to make available the output needed for the virtual machine.

RemarksThe size of the hard disk storage capacity which should be selected depends on various factors when using a virtualization solution:• Number of users, groups and terminals• Utilization scenario and incidence of communication• Activated video memory func-tion: If no video memory function is used, we recommend a hard disk storage capacity of at least 30 Gigabytes. When using the video memory function, please contact the Access Service Center to be advised on the minimum capacity required for the hard disk memory.• For Access systems with up to 50 users, server hardware can be used which corresponds to the performance data of Access server hardware S:• - Processor output: At least Intel Atom D510; 1.6 GHz dual-core• - Random access memory (RAM): at least 2 GB• Important: Please note that in this configuration, no virtualization and no additional system expansion are possible.

* For Access systems with up to 50 users, server hardware can be used which corresponds to the performance data of Access server hardware S:- Processor output: At least Intel Atom D510; 1.6 GHz dual-core- Random access memory (RAM): at least 2 GBImportant: Please note that in this configuration, no virtualization and no additional system expansion are possible.

Virtualization

Page 38: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

38

4 System components Network security

AGW 670-01 Access gateway for the physical sep-aration of 2 networks (e.g. customer network and Access network) at an Access server. To operate Access terminals in different networks, using one or more Access gateways in large network structures allows two or more proprietary networks to be linked to an Access system while ensuring that they remain strictly separate.The AGW 670-… can only be used in conjunction with Server Release V.2.1.3 Build 938 and higher.On a change of release, additional costs could be incurred under certain circumstances.Operating voltage: 12 V DCTypical current consumption: max. 24 WAmbient temperature: 0 °C to +50 °CDimensions (mm) W x H x D: 200 x 200 x 52

ASHT 170-0 Access application licence “Access Software In-house telephone” for the operation of ASHT software on the Access system. The ASHT enables audio and video door communication via Windows-based PCs or control panels.Function overview:• Call differentiation between door calls, storey calls and indoor calls• Device and user overview • Users, doors and devices can be selected from lists• Global contact list• Status displays of switchgear • Switching functions via ATLC/ATLCE or KNXSystem requirements:• Microsoft® Windows 7, 8, 8.1, 10• Microsoft® .NET Framework 4.6.1• Microsoft® VC++ 2013 Redistributable Package (x86)• Microsoft® VC++ 2015 Redistributable Package (x86)• At least Microsoft® DirectX® 9.0c• CPU: Dual-Core from 2.0 GHz• At least 2 GB RAM• Graphics card with at least 1280 x 720 pixel, 128 MB RAM• Ethernet card/Network connection: 100 Mbit• Sound card

Client-Software

ASC 170-0 Access application licence “Access Software Concierge” for the opera-tion of the ASC software on the Access system.The ASC is the central communica-tion interface at the reception.Function overview:• Several audio and video links can be depicted simultaneously• Convenient forwarding functions • Music-on-hold• Status overview of all Doormatic door statuses• Convenient switching/control and display functions• Global contact list (incl. personal contact management)• Camera scan function • Answering machine functionsSystem requirements:• Microsoft® Windows 7, 8, 8.1, 10• Microsoft® .NET Framework 4.6.1• Microsoft® VC++ 2013 Redistributable Package (x86)• Microsoft® VC++ 2015 Redistributable Package (x86)• At least Microsoft® DirectX® 9.0c• CPU: Dual-Core from 2.0 GHz• At least 2 GB RAM• Graphics card with at least 1280 x 720 pixel, 128 MB RAM• Ethernet card/Network connection: 100 Mbit• Sound card

www.siedle.de/access www.siedle.de/access

Page 39: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

39

Upgrade (server)

ASM 170-0 Access application licence “Access software module” for the opera-tion of ASM software on the Access system.The ASM enables Siedle Access to be integrated into non-Siedle systems (e.g. touch panels).You will be kept up to date with the latest information by our Project Sales DepartmentSystem requirements:• Microsoft® Windows 7, 8, 8.1, 10• Microsoft® .NET Framework 4.6.1• Microsoft® VC++ 2013 Redistributable Package (x86)• Microsoft® VC++ 2015 Redistributable Package (x86)• At least Microsoft® DirectX® 9.0c• CPU: Dual-Core from 2.0 GHz• At least 2 GB RAM• Graphics card with at least 128 MB RAM• Ethernet card/Network connection: 100 Mbit• Sound card

Software integration for non-Siedle systems

Siedle app for Access The Siedle app for Access turns the iPhone or iPad into a mobile exten-sion of an Access door intercom from Siedle: It allows you to see who is standing outside your door, talk to visitors at the entrance and open the door if you choose – no matter where you happen to be. The con-nection is established via WLAN or via the mobile phone network.If the app is not activated or if the bandwidth of the data network is not sufficient, the Access server automatically establishes a speech connection via the telephone net-work (call function). The call func-tion is only available for the iPhone.The Siedle app for Access can also perform switching and control func-tions, for example door release, light, garage door or shutters. Switching and control functions are encrypted for security purposes.

The complete functional scope of the Siedle app is described in the Apple App Store.

App

ASU 670-04 Access Server upgrade package for upgrading existing Access Server hardware with Access server software V. 1.x.x or V 2.x.x to Access Professional V 4.0.0.The Access server upgrade package can be purchased exclusively through an Access Certified Partner. To place the order, the serial number of the server hardware and the hardware ID of the existing access system are required. The upgrade may only be performed by an Access Certified Partner (ACP) or by the Access Service Center (ASC).Existing licences for the previous Access system remain valid, but must be converted.Scope of supply:• USB stick with system image (Microsoft Windows Server 2012 R2 for Telecommunication and Access Professional with 30-day test licence)• Microsoft End User Licence Agreement (EULA)• Windows Certificate of Authenticity (COA)• Upgrade instructions

www.siedle.de/accesswww.siedle.de/access

Page 40: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

40

4 System components Access licences

Licence management/Licence purchasing For regular operation of the Access system, an Access user licence for up to 320 users/devices must be pur-chased for a fee. Optional application licences enable the use of additional performance features.

Do you need Access licences?• Customers and sales partners from Germany, please consult one of our Siedle centres or one of our Access Certified Partners. * Also in your area.• Qualified staff are on hand to offer a fast, competent service.• By telephone, or where neces-sary we will be pleased to visit you on site.• Customers outside of Germany can contact one of our international representatives.(For detailed information, see page 152)

* Access Certified Partners (ACPs) are authorized to commission Access systems. They have proven their competency as planners and admin-istrators of Siedle Access systems, have passed independent audits per-formed by the accredited body TÜV Süd and are certified by Siedle.Contact details are available on the internet at www.siedle.com/acp

Notices – third party device licences For many requirements, the market is flooded by a large number of ideas and devices. Communication and compatibility between the dif-ferent components can sometimes be an issue. For this reason, it is advisable to make contact at an early stage with our project sales depart-ment. The link-up of new third-party devices / technical systems can be checked on customer request. For testing, a test device must be made available by the customer.

Procedure – Licence order

Access Professional(Software variant)

ASH 670-04 M/S(Access server hardware)

Test licencesThe trial period for an Access system without a valid Access user licence ends after 30 days.For regular operation of Access Professional, an Access user licence must be purchased against a fee.After expiry of the 30-day test period, the Access system is deacti-vated and cannot be used until the Access user licence is imported.Optional application licences enable the use of additional performance features.

Test licencesThe trial period for an Access system without a valid Access user licence ends after 30 days.For regular operation of Access Professional, an Access user licence must be purchased against a fee.After expiry of the 30-day test period, the Access system is deacti-vated and cannot be used until the Access user licence is imported.Optional application licences enable the use of additional performance features.

Time of placement of orderThe Access user licence and optional application licences must be ordered from an Access Certified Partner after Access Professional has been started for initial commissioning and the hardware ID has been gener-ated. For licence orders, the hard-ware ID generated by the Access system is required.

Time of placement of orderThe Access user licence and optional application licences must be ordered from an Access Certified Partner after Access Professional has been started for initial commissioning and the hardware ID has been gener-ated. For licence orders, the hard-ware ID generated by the Access system is required.

Microsoft licencesPlease check whether any Microsoft server access licences (Client Access License – CAL) are required by the customer for operation of the Access users, or whether these already exist. Microsoft Client Licences (CAL) are not included in the scope of supply of the Access server.

Microsoft licencesNo additional Microsoft server access licences (Client Access License – CAL) required.

Page 41: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

41

Access user licence packages – Server operation (All Access server variants)

Licence package – APR 670-0 [xx] Description

APR 670-0 10APR 670-0 20APR 670-0 40APR 670-0 80APR 670-0 160APR 670-0 320

An Access user licence is required for the regular use of Access Professional. The Access user licence allows Siedle Access Professional to be enabled and used in Version V 4.0.0 for up to 320 users/terminals per system (optionally inclusive of licensed hardware indoor stations/door stations and/or optional hardware and software terminals to be licensed). Access user licences can be purchased for 10, 20, 40, 80, 160 or 320 users/terminals and combined as required. The trial period for an Access system without a valid Access user licence ends after 30 days. Existing licences for the previous Access system remain valid, but must be converted.

Page 42: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

42

Optional Access application licences (All Access server variants) Optional application licences enable the use of additional performance features. These are sold exclusively through our Access Certified Partners, who will then also enable the licences for you.

Licence type Description

Third-party audio device (ALFA 270-0)

Access licence for third-party audio device, for link-up of a VoIP audio tele-phone to the Access system. An analogue telephone can be connected via a VoIP-ATA adapter. Third-party devices are subject to authorization by Siedle.

Non-Siedle smartphone device (ALFS 270-0)

The third-party smartphone Access licence permits connection of the smart-phone to the Access server. A separate licence is required per device. The smartphone functions as a mobile indoor device with video. An additional app is required for operation. This must be purchased from the App Store. (Currently only iPhones and not Android or Windows smartphones).

Non-Siedle tablet device (ALFT 270-0)

The Access licence for third-party tablets permits connection of the tablet to the Access server. A separate licence is required per device. The tablet functions as a mobile indoor device with video. An additional app is required for operation. This must be purchased from the App Store. (Currently only iPhones or iPads and not Android or Windows tablets).

Non-Siedle video device (ALFV 270-0)

Access licence for third-party video device, for link-up of a VoIP video tel-ephone to the Access system. A separate licence is required per device. Third-party devices are subject to authorization by Siedle.

KNX link (ALKNX 270-0 <50, <300, >300)

Access licence KNX connection for the import and management of KNX addresses; assignment of < 50 / < 300 / > 300 data points. You can send and receive KNX telegrams. Only one KNX gateway can be connected to the Access server.

Telephony link (ALT 270-0)

Access licence for telephone connection, for utilization of an external con-necting channel. A separate licence is required per channel.Third-party devices are subject to authorization by Siedle.

Access software concierge(ASC 170-0)

Access concierge licence for connection of the software client Access con-cierge software to the Access server. A separate licence is required per client.(Currently only PCs/laptops/tablets with Windows 7, 8, 8.1, 10)

Access in-house telephone(ASHT 170-0)

Access in-house telephone licence for connection of the software client in-house telephone to the Access server. A separate licence is required per client.(Currently only PCs/laptops/tablets with Windows 7, 8, 8.1, 10)

Software module(ASM 170-0)

Access software module licence for connection of the Access software module to the Access server. A separate licence is required per client.(Currently only PCs/laptops/tablets with Windows 7, 8, 8.1, 10)

4 System components Access licences

Page 43: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

43

Microsoft licences (CAL)

Microsoft Client Licences (CAL) are not included in the scope of supply of the Access server.

The Microsoft Client Access License (CAL) licences access by devices or users to Microsoft server operating systems whose licence model envis-ages that additional licensing is required every time the server soft-ware is accessed.

Customers who wish to operate the Access system on their own server must check whether CALS have to be purchased or whether the existing provision (in respect of the server type and CAL variant) is sufficient (e.g. the customer already has user CALs for all employees for the Windows server 2012. The cus-tomer is required to check its own licence agreements to determine whether these entitle users to access the Windows server of the Access system.).

CAL variants• Device CAL: A device CAL entitles all users to use a certain device with server access (e.g. PC in the workshop which is used by different employees.).• User CAL: A user CAL entitles a certain user to use any optional number of devices with server access (e.g. employee uses a PC, laptop and smartphone).

Page 44: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

44

5 Function overview

Calling, speech and video functions between door station and the con-nected Access indoor stations.An existing call can not be listened in to or viewed by other Access indoor call stations. Door release button for the door release function and 7 other buttons which can be assigned any optional functions. The defini-tion of functions and the relevant buttons take place during configura-tion of the server which assumes the function of central overall system administrator. The number of Access users is determined by the server.

Connection facility for a storey call button (ERT) for calling an apart-ment door and potential-free con-tact is available as standard.Different ringtones for calling from the front door, the apartment door, concierge or internal call.

Supplementary functions • Internal calls and speech commu-nication between Access indoor call stations are possible.• Connection of an analogue camera to the ATLC 670-… via the interface AIVS 670-…• Concierge function as central interface, e.g. at the reception• 8 freely selectable ringtones• Call forwarding• Call follow-me function• Parallel door and storey call• Group formation possible• Selective dialling of the door sta-tion using additional free buttons• Central video memory module (server) possible

Access system function Access system version

Communication V 4.0.x

Internal calls/internal conversations •

Audio and video privacy device •

Door call and door conversation with video •

Direct door call with video •

Storey call •

Echo compensation •

Active background noise suppression •

Call list with history (ASC/ASHT) •

Send and receive text messages (ASC/ASHT) •

Voicebox (ASC/ASHT) •

Storey call to groups configurable •

Acoustic feedback after pressing a call button •

AZIO configurable (additional input and output for AHT/AHTV, AHF/AHFV, AVP) •

Support of the ZAM 670 (Status display module) •

CTI-Call support with ASC/ASHT and external IP telephone •

• = available- = Not available

Page 45: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

45

Access system function Access system version

Video functions V 4.0.x

Central image memory •

Automatic and selective capture of a camera image per door call •

Selective capture, display and deletion of camera images/pictures •

Camera dialling via contact list or in video area •

Camera scan mode (ASC) •

Telephony functions

Connection of a telecommunications system to the Access Server (only VoIP) •

Selection of public network numbers •

Call using the landline network using a code lock •

Hold (ASC/ASHT) •

Brokering (ASC) •

Music on hold •

Call rerouting •

Call forwarding (ASC) •

Display of participant status •

Individual language setting (AHT/AHTV, AHF/AHFV, AVP) •

Supports DTMF tones (SIP info) for telephony connection •

Supports DTMF tones (RCF2833) for telephony connection •

Control functions (switching/control)

Doormatic function (target-, doorbased) with status indicator •

Support for binary KNX functions •

Switching functions configurable to call buttons •

ATLC input configurable •

Support for the ATLCE •

Inverting an output •

Retriggering an output •

Support for the mail notification system •

Page 46: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

46

5 Function overview

Access system function Access system version

Commissioning functions V 4.0.x

Browser-based commissioning •

Central management and configuration of participants and devices •

Group administration •

Several administrators with different authorisation levels •

Extended DHCP setting possibilities (from V 3.0.0 in the server operating system)

-

DHCP IP address range can be set •

NTP server can be set •

Remote configuration via the Access server's web interface •

Service functions

Configuration backup •

Remote maintenance and updates(Internet connection required!)

Monitoring of system capacity utilization (via dashboard) •

Manual line / user monitoring •

Management of software statuses in the Access server •

Detailed logging for Siedle support •

Interfaces

Connection to standardised IP telephone systems •

Integration of a / b converters •

External analogue cameras (with Access Interface Analog Video Standard – AIVS 670… to ATLC)

KNX or other building automation systems (e.g. Crestron or Control4) •

Link to video recording devices, operating displays and video servers via the den Access video decoupler

Compilation of customer-specific scripts for the automation of functions (optional and subject to charge)

Access control (via Vario bus) •

Page 47: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

47

Access system function Access system version

Client-Software V 4.0.x

ASHT: Overlay entire application on an incoming call •

ASHT: Automatic login and minimizing on Windows start-up •

ASC/ASHT: Confirmation request prior to closing the application •

ASM: Software module (integration in non-Siedle systems) •

App

Siedle app for Access (iPhone) •

Siedle app for Access (iPad) •

Hardware clients

AVP •

AVP with KNX •

AHF/AHFV •

AHT/AHTV •

Non-Siedle devices (SIP) •

• = available- = Not available

Page 48: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

48

* from Access-Server V 3.1… • = available- = Not available

6 Configuration – Access System Models

ATL

C 6

70-…

AH

F 87

0-…

AH

FV 8

70-…

AH

T 87

0-…

AH

TV 8

70-…

AV

P 87

0-…

ASC

 170

-…

ASH

T 17

0-…

ASM

 170

-…

Sied

le A

pp iP

ad

Sied

le a

pp iP

hone

SIP

vide

o te

leph

one

SIP

audi

o te

leph

one

Exte

rnal

tel

epho

nes

Bina

ry s

witc

hing

dev

ice

General

Name • • • • • • • • • • • • • • •

Description • • • • • • • • • • • • • • •

Address (KNX) - - - - - - - - - - - - - - •

Data type (KNX) - - - - - - - - - - - - - - •

Call number (Internal) • • • • • • • • • • • • • - -

Assignment • • • • • • • • • • • • • • -

Software type - - - - - - • • • • • - - - -

Account name - - - - - - • • • • • - - - -

Password (info field: Password is adopted from the user.)

- - - - - - • • • • • • • - -

Using as an autonomous telephone - - - - - - • • • - - - - - -

CTI device - - - - - - • • • - - - - - -

MAC address • • • • • • - - - - - - - - -

Installation type (Wall / table) - • • • • • - - - - - - - - -

Hardware revision • • • • • • - - - - - • • - -

Activate building automation * - - - - - • - - - - - - - - -

URL building automation * - - - - - • - - - - - - - - -

Ringtone volume - • • • • • - - - - - - - - -

Speech volume • • • • • • - - - - - - - - -

Display time at the terminal - • • • • • - - - - - - - - -

Microphone sensitivity • - - - - - - - - - - - - - -

Camera available • - - - - - - - - - - - - - -

Telephone script • • • • • • • • • • • • • • -

Size of audio frame [ms] - - - - - - - - - - - • • - -

Acoustic button acknowledgements • - - - - - - - - - - - - - -

Line prefix and (external) call number - - - - - - - - - - • - - • -

Page 49: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

49

ATL

C 6

70-…

AH

F 87

0-…

AH

FV 8

70-…

AH

T 87

0-…

AH

TV 8

70-…

AV

P 87

0-…

ASC

 170

-…

ASH

T 17

0-…

ASM

 170

-…

Sied

le A

pp iP

ad

Sied

le a

pp iP

hone

SIP

vide

o te

leph

one

SIP

audi

o te

leph

one

Exte

rnal

tel

epho

nes

Bina

ry s

witc

hing

dev

ice

Button configuration

Expert mode - • • • • - - - - - - - - - -

Single click - • • • • - - - - - - - - - -

Double click - • • • • - - - - - - - - - -

Press button - • • • • - - - - - - - - - -

Release button - • • • • - - - - - - - - - -

Entrance door light •

Buttons (The number is dependent on the equipment of the door stations)

• - - - - - - - - - - - - - -

Door release button / 2–8 - • • • • - - - - - - - - - -

Button / tile 1–44 - - - - - • - - - - - - - - -

Switching outputs/inputs

Voltage mode output 23,24 • - - - - - - - - - - - - - -

Output Terminals 23,24 • - - - - - - - - - - - - - -

Output Terminals 13,14 • - - - - - - - - - - - - - -

Output ANG Terminals 11,12,14 • - - - - - - - - - - - - - -

Output RJ45 Terminals 4,5 - • • • • • - - - - - - - - -

Inversion • • • • • • - - - - - - - - -

Retriggering • • • • • • - - - - - - - - -

Input Terminals 15,16,17,18 • - - - - - - - - - - - - - -

Input RJ45 Terminals 3,6 - • • • • • - - - - - - - - -

Page 50: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

50

6 Configuration – Access System Models

ATL

C 6

70-…

AH

F 87

0-…

AH

FV 8

70-…

AH

T 87

0-…

AH

TV 8

70-…

AV

P 87

0-…

ASC

 170

-…

ASH

T 17

0-…

ASM

 170

-…

Sied

le A

pp iP

ad

Sied

le a

pp iP

hone

SIP

vide

o te

leph

one

SIP

audi

o te

leph

one

Exte

rnal

tel

epho

nes

Bina

ry s

witc

hing

dev

ice

Extension of the switching out-puts/inputs

Door controller extension ATLCE 670-… (max. 3 ATLCE units per ATLC)

• - - - - - - - - - - - - - -

Hardware device extension AZIO 870-…(max. 1 AZIO per hardware terminal)

- • • • • • - - - - - - - - -

Doormatic

Time in seconds • • • • • • • • - • • - - - -

Doormatic function can be activated • • • • • • • (•)* - (•)* (•)* - - - -

• = available- = Not available

* The doormatic function is exclu-sively user-based with the Access in-house telephone software (ASHT) and the Siedle iPhone/iPad app and is only possible with Access server V 3.2 and above.

Page 51: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

51

Server administration – device parameters

General

Name Displayed device name in the Access system (contacts, phonebooks etc.).

Description Short description (e.g. model designation of the manufacturer or other information for device differentiation or logical assignment).

Address (KNX) Physical address of a KNX device in the KNX network (e.g. 10.12.200)

Data type (KNX) KNX function which can be initiated via the Access server. The Access server can send exclusively binary switching commands (On/Off).

Call number Internally assigned call number of the device (e.g. 121).

Assignment The standard entry is the designation of the higher-level user (e.g. Mr. Maier). The designation can be changed at any time.

Software type Unchangeable information field for categorization of the software client's software.

Account name Unchangeable information field. The account name is generated by the Access server and is required for login at the Access server.

Password Central password which was adopted from the higher-level users and is required for login at the Access server. The password is automatically assigned by the Access server and can be changed on the user level at any time.

Using as an autonomous telephone Selection of whether the software client should be used with or without a parallel operated CTI device (hardware terminal - e.g. AHT) (default set-ting: Yes = without). If the option No (No = with) has been defined, the additional configuration point CTI device appears in the menu. Via the selectable CTI device, speech input/output takes place while the software client continues to display the video image.

CTI device Terminal which takes over audio communication for a software client when the option Use as autonomous telephone has been configured with No.

MAC address Unique physical hardware address of the Access indoor station or the Access door loudspeaker controller.

Installation type Only with Access indoor stations AHF and AHFV. Depending on the mounting method (wall or table-top operation), the microphone behaviour changes (echo cancelling). With table-top operation, echo formation can occur when choosing the wrong mounting method, as the microphone is located on the underneath of the device and feedback can be created at the loudspeaker due to reflections from the tabletop.

Hardware revision Unchangeable information field which indicates the revision status of this indoor device.

Page 52: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

52

* Only SIP provider/gateway, non-Siedle devices (with ALFA/V licence)

6 Configuration – Access System Server administration – device parameters

Activate building automation * Activate or deactivate access to the building automation.

URL building automation * URL of the building automation server (Facility Pilot Server) with port indication (8080) in the prescribed form http://[IP address]:[Port] whose user interface you wish to be displayed in the AVP (e.g. http://192.168.1.10:8080).

Ringtone volume Ringtone volume of the device, which can be set from 0 to 100 %.

Speech volume Voice volume of the receiver or handsfree speaker, which can be set from 0 to 100 %.

Display time at the terminal Selection of whether the time should be displayed at the indoor device or not.Note: If you operate an Access system in several time zones, this option should be deactivated, as the Access server can only make available one time for the Access indoor stations.

Microphone sensitivity Microphone sensitivity of the door station, which can be set from 0 to 100 %.

Camera available Non changeable information field indicating whether there is a camera installed at the respective door station or not.

Telephone script Server logic deployed for calls at the door (e.g. standard telephone script). Several telephone scripts are available to choose from as standard in the Access system:

• Standard telephone script: Standard script used to allow communica-tion and standard functions to be carried out.• Secondary signal unit: Extended standard script to allow the additional connection of a secondary signal unit (e.g. visual signal unit in loud environ-ments). Can only be used if this terminal makes available a potential-free contact which is addressable.• Camera actuation: Extended standard script to allow the additional con-nection of a camera actuating device (e.g. video surveillance system covers the door area if a door call is initiated by a person).

A potential-free switching contact is required for the “secondary signal unit” and the “camera actuation” script in order to enable signalling to third-party devices/systems. These two scripts can only be used for Siedle hardware terminals, as the PC software and app cannot make switching contacts available. In addition, the third-party device/system must enable the connection of potential-free contacts. Only use the scripts in case of a concrete requirement and not as a standard selection.

Page 53: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

53

Size of audio frame [ms] * For transporting audio signals in the network, a length of 20 ms or 40 ms can be selected for the audio frames. The value to be selected depends on the external SIP device used.

Acoustic button acknowledgements Acoustic feedback at the door station when pressing a call button. A standard acknowledgement tone is output. Alternatively a suitable audio file can be imported and used for output of a button acknowledgement (see menu System maintenance > Acoustic button acknowledgements).

Line prefix and (external) call number

Telephony route which determines which telephony gateway can be reached using which call number including country dialling code (e.g. 0 and 004977231234567890). For this, a preconfigured telephony gateway and a call number plan are required.

Button configuration

Expert mode The button configuration is assigned as standard with the single click and double click modes and can be upgraded by activating the expert mode to include the press button and release button modes.

Single click A function is initiated when pressing the button.

Double click A function is initiated when quickly pressing a button twice and releasing.

Press button When pressing the button (rising signal / edge) a function is initiated.

Release button When releasing the button (dropping signal / edge) a function is initiated.

Button functions

No action Button has no function.

Device call Call a selected device (e.g. ASHT – Mr. Maier).

User call Call to all the devices of the selected user (e.g. Mr Maier).

Group call Call to all devices of the users that are configured in the called call group (e.g. Purchasing department group).

External call Calling any optional (external) call number (preconfigured telephony gateway and call number plan required).

Page 54: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

54

Rerouting to device/participant/group/external

Optional call rerouting to devices of the same or a different user, to a dif-ferent user, to a different group or to an external call number (preconfigured telephony gateway and call number plan required).In this way, you can configure a call rerouting function in the Access system from any call number (rerouting source) to any call number (rerouting destination) and assign the function to a device button. The devices, users, groups or external call number to which a call rerouting function can be established depends on the rights.

Explanation:• Rerouting source: The call number from which the incoming calls have to be rerouted. Users or groups can be selected as the rerouting source – not devices. The user of the device for which you are configuring the call rerouting is always pre-selected as standard as the rerouting source. If you want to reroute calls to a group or another user (depending on their rights), you must adjust the rerouting source accordingly. Only the calls to the call number specified in the rerouting source are rerouted to the stored rerouting destination. The rerouting destination can be a device, a user, a group or an external call number. Direct calls to a device are not covered by call rerouting! Example: Incoming calls to the Purchasing group should be rerouted to Mr Maier. Configuration in Access system: Rerouting to user -> Mr Maier // rerouting source: Purchasing groupThe devices or users to which calls can be rerouted depends on the logical grouping in the user tree and the relevant user rights settings.• Rerouting destination: The call number to which all incoming calls are rerouted at the configured rerouting source. The rerouting destination can be a device, a user, a group or an external call number.

6 Configuration – Access System Server administration – device parameters

Page 55: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

55

Scripts and switching functions Selection of available scripts and switching functions for devices and doors (selection is dependent on the devices and Access door loudspeaker control-lers used):• Switching point: Selection of a function in order to be able to trigger this remotely: • Switching output for an Access indoor station (AHF/AHFV, AHT/AHTV, AVP) or a door station (ATLC+ANG/ATLCE) with switching right (e.g. pressing the button switches the light on in the cellar). An active switching output is indicated by a red LED button. • Doormatic function for one’s own user. In order to be able to select the option, “Doormatic can be activated” must be activated for one’s own user. An active doormatic is indicated by a white LED button. • Binary switching device (KNX) which has been integrated into the Access system.• Status point display: With the “Set” button you can determine whether an active switching output or an active doormatic function should be indi-cated via the LED button. Active switching outputs are indicated in “red” and active doormatic functions in “white”. A button with configured status point indicator is used as a pure status element.• Door release last door: If this button is pressed, the door release of the currently calling door is triggered, otherwise the door release of the door last connected to the device is triggered. This function is not indicated visu-ally.• Door light last door: If this button is pressed, the door light of the cur-rently calling door is switched, otherwise the door light of the door last con-nected to the device is switched. This function is not indicated visually.• Muting the microphone: The microphone of an Access indoor station can be deactivated and reactivated using the device button (e.g. for private comments in the room which are not to be heard by the call partner at the door station). If the microphone is muted, the device button lights up red. If a call is ended while the microphone is deactivated, the microphone is automatically reactivated.• Muting the ring tone: The ring tone of an Access indoor station can be muted via the device button when there is a call pending or when there is no call pending. If this function is active, incoming calls are only visually displayed on the terminals (depending on the device, by a flashing button/call button). If the ring tone is muted, the device button lights up red. After a restart of the Access server, incoming calls are indicated both acoustically and visually again.• Setting the user to Do not disturb: If this function is activated, no user or device calls are indicated on any of this user’s devices. The user is marked red in the contact list. Callers receive the engaged tone. The device button lights up red when the function is active.

Page 56: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

56

Scripts and switching functions • Setting the user to Do not disturb: If this function is activated, no user or device calls are indicated on any of this user’s devices. The user is marked red in the contact list. Callers receive the engaged tone. The device button lights up red when the function is active.• Parameterized button script: Individual control script which has been integrated in the Access server for implementing customer-side special requests (e.g. special functions or control sequences which are to be controlled via the Access server), can be assigned to a button with an Access indoor station and configured via the “Set” button. The scripts need to be imported into the “Scripts” menu in advance. The displayed name Parameterized button script is only an example and can be changed for the scripts before import.

Remarks• If other parameters have to be configured stored for a particular button assignment (e.g. with one switching point), the button Setting becomes active. After clicking on Setting, a dialogue is displayed in which the rel-evant required data can be selected or entered.• The devices or users to which calls can be rerouted depends on the logical grouping in the user tree and the relevant user rights settings. • Using Scripts and switching functions > Switching point, the Doormatic function can be assigned to one of the buttons – provided the Doormatic function is activated for the user to which the device assigned.

Switching outputs/inputs The number of switching outputs/inputs available for configuration depends on the equipment of the Access door loudspeaker controller (e.g. additional extension module).

Switching function – Switching outputs

The functions (no action, free switching time, door release, door light) can be assigned to the relevant switching output.

Switching function – Switching inputs

The functions (no action, switching point, storey call, and signal status) can be assigned to this switching output.

Static switching operation (Toggle 0s)

Binary switching operation (ON / OFF)

Timed switching operation (door release / door light / free switching time)

Free switching time - timed switching operation (for door release / door light / free switching time): ON for (0.4 s / 1-59 s / 1-10 Min / 15-20-…-55 Min / 1-12 h) / OFF / (0 s) Toggle

Inverted The functions Free switching time, Door release and Light switching can be operated inverted (ON becomes OFF / OFF becomes ON).

6 Configuration – Access System Server administration – device parameters

Page 57: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

57

Retriggerable Timed switching operation can additionally be retriggered (restart of the timed switching operation for the programmed switching time from when the button is pressed again in running switching operation).

Switching point The following functions can be triggered via a switching point:• Switching output of an Access end device located and enabled in the Access system (e.g. key-operated switch on the ground floor triggers a door release in the cellar via an indoor station)• Doormatic of an Access door controller located and enabled in the Access system (e.g. pressing the call button triggers the door release – doctor’s surgery)• Binary switching device (KNX) which is integrated into the Access system (e.g. pressing a button of an indoor station switches the light on via the KNX system)

To allow the Doormatic function to be activated from an Access indoor sta-tion, Access software client, at the relevant door/door station and the users of the affected devices, the option Doormatic can be activated must be activated. In addition, the Doormatic function must then be configured to a button of the relevant device in order to allow the Doormatic function to be activated and deactivated at a device.

If a configurable button on an Access indoor station is used as a trigger, then the function of a switching point can be triggered by a selectable actuation version:• Single click• Double click• Press button• Release button

For all other triggers (tile, button, switching input), the function of the switching point, where available, is only triggered when there is an incoming input signal (rising edge change) (e.g. potential-free button on a switching input is pressed).A switching output can be configured both for toggle or temporal switching operation as well as for invertibility and/or for retriggering. Doormatic can be activated and deactivated depending on the trigger in a user-based manner or depending on the door station. A binary switching device can be activated and deactivated.

Page 58: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

58

6 Configuration – Access System Server administration – device parameters

Switching point Depending on the end device and its trigger, the following functions can be activated via a switching point:

End

dev

ice

Trig

ger

/fu

nct

ion

Swit

chin

g o

utp

ut

Do

orm

atic

use

r-re

late

d

Do

orm

atic

do

or-

bas

ed

Bin

ary

swit

chin

g

dev

ice

AHT/AHTV, AHF/AHFV

Configured button • • • •

Operating menu • • – •

AVP Configured tile • • • •

Operating menu • • – •

ASHT Function button • • – –

Operating menu • – – •

ASC Function button • • – –

Operating menu • – • •

App Function button • • – •

Operating menu • • – •

Favourites list • * • – •

Configured rooms • – – •

Configured scenes • * – – •

AHT/AHTV, AHF/AHFV,AVP, ATLC

Switching input • – – •

* no DR contacts

Page 59: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

59

Story call Call signalling that can be displayed on your own device or a freely selectable user or a freely selectable group. If the potential-free contact at the input terminal of the terminal is closed, then the storey call is indicated for approx. 5 seconds. Here you can configure the device/user/group for which the storey call is to be indicated. Before you can assign a group to the storey call, a group must be configured.

Signal status Signal that is triggered when the potential-free contact at the input ter-minal of the terminal is closed (e.g. mail notification system). To assign this function to a button, you need to configure the switching input to “Signal status” and then save it. Then you can assign this switching input to one of the buttons on your devices in the “Button configuration > Status point display” area. Every user which has the right to display this input signal can have the input signal displayed at any optional device which is capable of visualizing status displays.If other parameters have to be configured for a particular button assign-ment (e.g. with one switching point), the Set button becomes active.After clicking on Set, a dialogue is displayed in which the relevant required data can be selected or entered.

Page 60: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

60

7 Access control through the Vario bus Ranges in the Vario bus

The modules COM/ELM or FPM 611-… are used to actuate con-trol functions which are evaluated and implemented by the evaluating unit EC 602-…In order to utilize Vario bus control functions, an additional conductor with 4 cores is required from the input module to the EC 602-…For more information on access con-trol, contact our Project Service.

The range depends on the type of installation, the core diameter and the connected load values “AW” of the connected devices.

Range between the transformer and input modules with star-shaped installation. Max. 250 m using 0.8 mm core diameter and with connected load value “AW” 1. A second connected load value in the same line halves the range.

Connected load values AW

FPM 611-… 2

COM 611-… 1

ELM 611-… 1

EC 602-… 1

One TR 603-… supplies 2 AWsOne TR 602-… supplies 5 AWs

The conductor network laid throughout the entire Vario bus must not exceed 2000 m.

Page 61: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

61

Access control with Easikey con-troller EC 602-… as independent system

Access control with door controller IP TCIP 603-… as independent system

4ECE 602-...EC 602-...

TR 603-...

FPM 611-...

COM 611-...

ELM 611-...

ELM/COM max. 250 m

FPM max. 130 m

4 TCIP 603-...

VNG 602-...

FPM 611-...

COM 611-...

ELM 611-...

ELM/COM max. 250 m

FPM max. 130 m

Page 62: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

62

7 Access control through the Vario bus Distribution components – Transformers

TR 602-01 Transformer in switch panel housing for supplying additional components (e.g. easikey controller for access control).Operating voltage: 230 V AC, +/-10 %, 50/60 HzOperating current: 170 mAOutput voltage: 12 V ACOutput current: max. 2.5 AFusing: Secondary side with thermal fuseProtection system: IP 20Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 6Dimensions (mm) W x H x D: 107 x 89 x 60

TR 603-0 Transformer in switch panel housing for supplying additional components (e.g. mail notification system or door release via potential-free contact).Operating voltage: 230 V AC, +/-10 %, 50/60 HzOperating current: 100 mAOutput voltage: 12 V ACOutput current: max. 1.3 AFusing: Secondary side with thermal fuseProtection system: IP 30Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 3Dimensions (mm) W x H x D: 53.5 x 89 x 60

Page 63: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

63

Modules

ELM 611-01 Electronic key reading module as a contactless access control system with LED function.As reading unit of electronic keys or cards for opening doors, gates etc.Suitable for:• “stand-alone” mode, a maximum of 9 electronic keys or cards can be used.• in conjunction with entrance con-troller EC 602-… a maximum of 899 electronic keys or cards can be used.Programming takes place using PRI 602-… or PRI 602-… USB.• in conjunction with door con-troller IP TCIP 603-… a maximum of 500 users possible (larger systems on request).Programming via web browser.Operating voltage: 12 V ACOperating current: 120 mAContact type: contact 24 V, 1 AProtection system: IP 54Ambient temperature: –20 °C to +55 °CDimensions (mm) W x H x D: 99 x 99 x 27

COM 611-02 Code lock module as an input device for the placement of door calls and control functions in conjunction with Access and the Siedle access control system.• in conjunction with entrance con-troller EC 602-… for setting control function and access control codes.Programming takes place using PRI 602-… or PRI 602-… USB and provided PRS 602-…• in conjunction with door con-troller IP TCIP 603-… for setting control function and access control codes.Programming via web browser• Operation with call controller RC 602-…, for programming codes for door calls, a C button to delete incorrect entries and a DR button for direct door release. This door release function can additionally be con-trolled by a time switch provided by the user. An integrated LED can be used via an external potential-free contact as a status indication.Operating voltage: 12 V ACOperating current: max. 140 mAProtection system: IP 54Ambient temperature: –20 °C to +55 °CDimensions (mm) W x H x D: 99 x 99 x 27

FPM 611-02 Fingerprint module as access control system with function LED.Suitable for:• Stand-alone operation• Operation with entrance controller EC 602-…Programming takes place using PRI 602-… USB or PRI 602-… and provided PRS 602-…• Operation with door controller TCIP 603-…Programming by means of web browserOperating voltage: 12 V ACOperating current: max. 250 mAContact type: contact 24 V, 2 ASwitching time: 3 secProtection system: IP 54Ambient temperature: –20 °C to +55 °CHeight of structure (mm): 17Dimensions (mm) W x H x D: 99 x 99 x 43

1 2 3

4 5 6

7 8 9

F 0 C

Page 64: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

64

TCIP 603-03 Door controller IP TCIP 603-… as a control unit for management of access entitlement in private homes and commercial properties.It is operated directly via a PC network (Ethernet standard 10/100 Mbit). Operation takes place using Microsoft Internet Explorer, current Version.• Actuation possible via code lock module COM 611-…, electronic key reading module ELM 611-… or fingerprint module FPM 611-… To increase security, two different access modules – e.g. COM/FPM 611-… – can be used in com-bination.• Password protected• Central management in the net-work via any optional PC (Internet Explorer current version)• Logging of access and system data• Attendance/absentee list as log (when using separate entrance and exit readers, i.e. 2 readers per door)• 5 entrances (e.g. door contacts)• 4 exits (e.g. door release)• with FSM 740-… and SCE 640-… extension possible by further inputs and outputs• Connection to Ethernet via RJ45 interface• LEDs for status display of entrances• 20 different time models possible• Max. 40 access groups• Management of up to 8 doors• Max. 500 users with 4 character-istics per user such as fingerprint, card or code• Max. 100 fingerprints can be scanned in

TCIP SRV 603-0 The Door controller IP server TCIP SRV 603-… is used to net-work several door controllers IP TCIP 603-… and to extend the maximum number of users which can be managed to over 500.Frequent settings and changes under the headings Time profiles, Public holi-days/vacation, Access groups and users are centrally managed and stored for several TCIP 603-… units.• Password protected• Central management in the network via any optional PC (Internet Explorer current version)• Logging of access and system data• Attendance/absentee list as log (when using separate entrance and exit readers, i.e. 2 readers per door)• Over 500 users, depending on the capacity of the network• Max. 100 fingerprints can be scanned in• Local configuration of menu points Inputs, Outputs, Readers, Network, System time/Time change and Doors• Automatic time adjustment (when accessing NTP time server)Operating voltage: 90–264 V AC, 47–63 HzTypical current consumption: max. 45 WHorizontal pitch (HP): 3 x 12Ambient temperature: +10 °C to +50 °CDimensions (mm) W x H x D: 328 x 88.8 x 201

• Variable public holiday and vaca-tion profiles• Automatic time changeover (sum-mertime/normal time)Operating voltage: 20–30 V DCOperating current: max. 700 mAContact type: Contact 15 V AC, 30 V DC, 2 AProtection system: IP 20Ambient temperature: 0 °C to +40 °CDimensions (mm) W x H x D: 131 x 111 x 52

7 Access control through the Vario bus Distribution components – Server/controller

TCIP 603

Page 65: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

65

EC 602-03 Entrance controller in switch panel housing for code lock module COM 611-…, electronic key reading module ELM 611-… or fingerprint module FPM 611-…Display-supported programming of integrated buttons, or by means of PC software via additional program-ming interface PRI 602-… Electronic evaluating circuit with 2 switching outputs, extendable to 8 with ECE 602-…, 2 control inputs for time-controlled access rights.Entrance controller as electronic evaluating circuit for switching func-tions in conjunction with modules COM 611-02, ELM 611-01 and FPM 611-02*Operating voltage: 12 V ACOperating current: 150 mAContact type: 2 changeover switches 24 V, 2 AAmbient temperature: 0 °C to +40 °CProtection system: IP 20Horizontal pitch (HP): 6Dimensions (mm) W x H x D: 107 x 89 x 60

*FPM 611-02 programming only possible at the PC, accessories required.

ECE 602-0 Entry controller extension in switch panel housing. Upgrades the EC 602-… by a further 6 working contacts.Operating voltage: 12 V ACOperating current: max. 400 mAContact type: 6 n.o. contacts, 24 V, 2 AAmbient temperature: 0 °C to +40 °CProtection system: IP 20Horizontal pitch (HP): 3Dimensions (mm) W x H x D: 53.5 x 89 x 60

ZRE 600-0 19 inch rack mounting accessory for the Access Server S and the TCIP server. Comprising retaining plate including mounted handles and mounting accessories.Dimensions (mm) W x H x D: 483 x 88 x 132

Page 66: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

66

8 Access circuit diagrams Overview

Device category Page Door loudspeaker Con-troller

Cameras/distributors Video inter-faces

Function modules

Peripherals

Models

ATL

M 6

70-…

CA

TLE 

670-

SATL

M 6

70-…

ATL

E 67

0-…

ATL

C/

NG

 670

-…

AC

M 6

73-…

CA

CM

 673

-…

SAC

M 6

73-…

SVTM

C 6

40-…

Exte

rnal

cam

era

Vid

eo d

istr

ibut

or

AIV

S 67

0-…

AVA

670

-…

DRM

 612

-…

CO

M 6

11-…

/ EC

602

-…

ZWA

 640

-…

DSC

  602

-0

PME 

600-

Siedle Vario Basic circuit diagram (Video) 70 • • •

Potential-free door release work contact A2 72 • • •

Potential-free door release changeover contact A3 74 • • •

Additional power supply 76 • • •

Pilfer safeguard 78 • • • •

Video decoupler (camera in switching operation) 80 • • • •

Video decoupler (camera in continuous operation) 82 • • • •

External camera 84 • • • •

External camera and video decoupler 86 • • • • •

Code lock module as access control and direct dial 88 • • • •

Display call module 90 • • • • •

2 door stations/display call modules 92 • • • • •

Radio chime 94 • • •

Basic circuit diagram (Audio) 96 • •

Access custom-fit door loud-speaker

Access camera module 98 • • • •

External camera 100 • • • •

Basic circuit diagram (Audio) 102 • •

Siedle Classic Wiring diagram for call buttons 104

Basic circuit diagram (Video) 106 • • •

Video decoupler (camera in continuous operation) 108 • • • •

2 mail notification systems 110 • • • •

Code lock module as access control and direct dial 112 • • • •

Siedle Steel Basic circuit diagram (Video) 114 • • •

Video decoupler (camera in continuous operation) 116 • • • •

2 mail notification systems 118 • • • •

Code lock module as access control and direct dial 120 • • • •

Flush mounted camera 122 • • •

Display call module 124 • • • • •

Camera connection

External camera with video distributor 126 • • • •

External camera 128 • • •

Storey call button

Customer-side signalling device130

• = available

Page 67: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

67

Device category Page Door loudspeaker Con-troller

Cameras/distributors Video inter-faces

Function modules

Peripherals

Models

ATL

M 6

70-…

CA

TLE 

670-

SATL

M 6

70-…

ATL

E 67

0-…

ATL

C/

NG

 670

-…

AC

M 6

73-…

CA

CM

 673

-…

SAC

M 6

73-…

SVTM

C 6

40-…

Exte

rnal

cam

era

Vid

eo d

istr

ibut

or

AIV

S 67

0-…

AVA

670

-…

DRM

 612

-…

CO

M 6

11-…

/ EC

602

-…

ZWA

 640

-…

DSC

  602

-0

PME 

600-

Siedle Vario Basic circuit diagram (Video) 70 • • •

Potential-free door release work contact A2 72 • • •

Potential-free door release changeover contact A3 74 • • •

Additional power supply 76 • • •

Pilfer safeguard 78 • • • •

Video decoupler (camera in switching operation) 80 • • • •

Video decoupler (camera in continuous operation) 82 • • • •

External camera 84 • • • •

External camera and video decoupler 86 • • • • •

Code lock module as access control and direct dial 88 • • • •

Display call module 90 • • • • •

2 door stations/display call modules 92 • • • • •

Radio chime 94 • • •

Basic circuit diagram (Audio) 96 • •

Access custom-fit door loud-speaker

Access camera module 98 • • • •

External camera 100 • • • •

Basic circuit diagram (Audio) 102 • •

Siedle Classic Wiring diagram for call buttons 104

Basic circuit diagram (Video) 106 • • •

Video decoupler (camera in continuous operation) 108 • • • •

2 mail notification systems 110 • • • •

Code lock module as access control and direct dial 112 • • • •

Siedle Steel Basic circuit diagram (Video) 114 • • •

Video decoupler (camera in continuous operation) 116 • • • •

2 mail notification systems 118 • • • •

Code lock module as access control and direct dial 120 • • • •

Flush mounted camera 122 • • •

Display call module 124 • • • • •

Camera connection

External camera with video distributor 126 • • • •

External camera 128 • • •

Storey call button

Customer-side signalling device130

Page 68: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

68

8 Access circuit diagrams Switching outputs/inputs

Model Number of switching outputs Number of switching inputs

Indoor stations Standard max. fully extended system

Standard max. fully extended system

AHF/AHFV/AHT/AHTV/AVP 1 2 1 2

Fully extended system with max. 1 extension (AZIO) per indoor station 1 - 1 -

Door controller

ATLC/NG 670-0 3 15 1/1 7/7

ATLCE extension 4 - 2/2 -

Fully extended system with max. 3 extensions (ATLCE) per ATLC 12 - 6/6 -

Device type Switching outputs

A1 A2 A3 A4

Indoor stationsAHF/AHFV/AHT/AHTV/AVP

N.O. contact 30 V, 1 ATerminals (4, 5)

- - -

Indoor stationsExtension AZIO

- N.O. contact 30 V, 1 ATerminals (7, 8)

- -

Door controllerATLC

Prog. door release output10-16 V AC, max. 700 mA13 V DC, max. 300 mATerminals (23, 24)

N.O. contact 30 V, 2 ATerminals (13, 14)

Changeover contact 250 V, 6 ATerminals (11, 12, 14)

-

Door controller extensionATLCE

Changeover contact 30 V, 2 ATerminals (11, 12, 14)

Changeover contact 30 V, 2 ATerminals (21, 22, 24)

N.O. contact 30 V, 2 ATerminals (31, 34)

N.O. contact 30 V, 2 ATerminals (41, 44)

The number of switching outputs and inputs can be extended for each indoor station and each door controller. The following list contains the as-delivered status and the max-imum full extension per device type.

Page 69: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

69

Device type Switching inputs

E1 E2

Indoor stationsAHF/AHFV/AHT/AHTV/AVP

Potential-free contactmin. 20 V DC, 10 mATerminals (3, 6)Storey call button (ERT)

- - -

Indoor station upgrade AZIO - Potential-free contactmin. 20 V DC, 10 mATerminals (1, 2)

-

Door controllerATLC

Potential-free contactmin. 20 V DC, 10 mATerminals (15, 16)

Galvanically iso-latedmax. 4-30 V DC, 10 mATerminals (17, 18)

- -

Door controller extensionATLCE

Potential-free contactmin. 20 V DC, 10 mATerminals (15, 16)

Galvanically iso-latedmax. 4-30 V DC, 10 mATerminals (17, 18)

Potential-free contactmin. 20 V DC, 10 mATerminals (25, 26)

Galvanically iso-latedmax. 4-30 V DC, 10 mATerminals (27, 28)

The Siedle Access device log is avail-able for commissioning support and documenting the switching outputs and inputs used.The Siedle Access device log can be found in the Siedle download area/as a supplement for each of the network-capable Access compo-nents at www.siedle.com

Page 70: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

70

ATL

M

BTM

23 24 V1

D2

S2S1 S3 D1

S4V2

V5

V6

V6

V5

S4S3 D2

D1

S2V2

S1V1 c1 bc V2

V1

V4

V3

L1N

AC

M

ATL

C 6

70-.

..A

NG

600

-...

LAN

a)m

)b1

Sied

le V

ario

AC

M 6

73-.

..A

TLM

670

-...

BTM

650

-...

IN

Rem

arks

Dev

ice

requ

irem

ent

Doo

r re

leas

e (T

ö) 1

2 V

AC

/DC

min

. 20

Ohm

230 V AC

8.1 Siedle Vario Basic circuit diagram (Video)

Page 71: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

71

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• The use of the potential-free switching outputs is described in separate diagrams.(For detailed information, see page 72, 74)

m) Where there are more than 10 BTM 650-… units, an addi-tional 12 V AC supply, for instance TR 603-…, must be installed due to the current consumption. To use the additional supply, the jumpers on the ATLM are removed from b1/c1 to b/c and the b/c terminals are directly connected to the additional supply. The jumpers for the ACM camera module between the terminals V3/V4 and the terminals b1/c1 remain as they are.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of an additional power supply is described in a separate diagram.(For detailed information, see page 76)

Page 72: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

72

Sied

le V

ario

ATL

M 6

70-.

..BT

M 6

50-.

..

AC

M 6

73-.

..

ATL

M

BTM

13 14 V1

D2

S2S1 S3 D1

S4V2

V5

V6

V6

V5

S4S3 D2

D1

S2V2

S1V1 c1 bc V2

V1

V4

V3

L1

230 V AC

N

AC

M

ATL

C 6

70-.

..A

NG

600

-...

LAN

a)

b1

A2

m)

IN

Rem

arks

Dev

ice

requ

irem

ent

Pote

ntia

l-fre

e co

ntac

tD

oor

rele

ase

actu

atio

nm

ax. 3

0 V

AC

/DC

, 2 A

e.g.

for

exi

stin

g ac

cess

con

trol

or

doo

r re

leas

e on

site

8.1 Siedle Vario Potential-free door release work contact A2

Page 73: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

73

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• The use of the door release switching output A1 (ATLC terminals 23, 24) is described in the video basic circuit diagram.(For detailed information, see page 70)

m) Where there are more than 10 BTM 650-… units, an addi-tional 12 V AC supply, for instance TR 603-…, must be installed due to the current consumption. To use the additional supply, the jumpers on the ATLM are removed from b1/c1 to b/c and the b/c terminals are directly connected to the additional supply. The jumpers for the ACM camera module between the terminals V3/V4 and the terminals b1/c1 remain as they are.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of an additional power supply is described in a separate diagram.(For detailed information, see page 76)

Page 74: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

74

A3

14 11 12

Sied

le V

ario

ATL

M 6

70-.

..BT

M 6

50-.

..

AC

M 6

73-.

..

ATL

M

BTM

V1

D2

S2S1 S3 D1

S4V2

V5

V6

V6

V5

S4S3 D2

D1

S2V2

S1V1 c1 bc V2

V1

V4

V3

L1

230 V AC

N

AC

M

ATL

C 6

70-.

..A

NG

600

-...

LAN

a)

b1

m)

IN

Rem

arks

Dev

ice

requ

irem

ent

Pote

ntia

l-fre

e co

ntac

tm

ax. 2

50 V

AC

/DC

, 6 A

e.g.

for

exi

stin

g ac

cess

con

trol

or

doo

r re

leas

e on

site

8.1 Siedle Vario Potential-free door release changeover contact A3

Page 75: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

75

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• The use of the door release switching output A1 (ATLC terminals 23, 24) is described in the video basic circuit diagram.(For detailed information, see page 70)

m) Where there are more than 10 BTM 650-… units, an addi-tional 12 V AC supply, for instance TR 603-…, must be installed due to the current consumption. To use the additional supply, the jumpers on the ATLM are removed from b1/c1 to b/c and the b/c terminals are directly connected to the additional supply. The jumpers for the ACM camera module between the terminals V3/V4 and the terminals b1/c1 remain as they are.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of an additional power supply is described in a separate diagram.(For detailed information, see page 76)

Page 76: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

76

8.1 Siedle Vario Additional power supply

Sied

le V

ario

ATL

M 6

70-.

..BT

M 6

50-.

..

AC

M 6

73-.

..

ATL

M

BTM

23 24 V1

D2

S2S1 S3 D1

S4V2

V5

V6

V6

V5

S4S3 D2

D1

S2V2

S1V1 c1 bb1

V2

V1

V4

V3

L1

230 V AC

NN

L1c b

230 V AC

AC

M

ATL

C 6

70-.

..A

NG

600

-...

LAN

TR 6

03-.

..

a)g)

, k)

c

IN

Rem

arks

Dev

ice

requ

irem

ent

Doo

r re

leas

e (T

ö) 1

2 V

AC

/DC

min

. 20

Ohm

Page 77: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

77

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• The use of the potential-free switching outputs is described in separate diagrams. (For detailed information, see page 72, 74)

g) Is only required if more than 10 BTM 650-… units are installed at this door station.

k) If the BTM 650-… units are sup-plied via a separate transformer, no connection between c1 and c / b1 and b may exist at the ATLM 670-… terminal block.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)

Page 78: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

78

Sied

le V

ario

ATL

M 6

70-.

..BT

M 6

50-.

..

AC

M 6

73-.

..

ATL

M

BTM

23 24 V1

D2

S2S1 S3 D1

S4V2

V5

V6

V6

V5

S4S3 D2

D1

S2V2

S1V1 c1 bc V2

V1

V4

V3

L1

230 V AC

NN

L1c b

230 V AC

AC

M

ATL

C 6

70-.

..A

NG

600

-...

LAN

TR 6

03-.

..

c b M1

M2

DSC

602

-...

a)m

)b1

bl

bl

gr

gr

IN

Rem

arks

Dev

ice

requ

irem

ent

Doo

r re

leas

e (T

ö) 1

2 V

AC

/DC

min

. 20

Ohm

8.1 Siedle Vario Pilfer safeguard

Page 79: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

79

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• The use of the potential-free switching outputs is described in separate diagrams.(For detailed information, see page 72, 74)

m) Where there are more than 10 BTM 650-… units, an addi-tional 12 V AC supply, for instance TR 603-…, must be installed due to the current consumption. To use the additional supply, the jumpers on the ATLM are removed from b1/c1 to b/c and the b/c terminals are directly connected to the additional supply. The jumpers for the ACM camera module between the terminals V3/V4 and the terminals b1/c1 remain as they are.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of an additional power supply is described in a separate diagram.(For detailed information, see page 76)

Page 80: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

80

Sied

le V

ario

ATL

M 6

70-.

..BT

M 6

50-.

..

AC

M 6

73-.

..

ATL

M

BTM

23 24 V1

D2

S2S1 S3 D1

S4V2

V3

V6

V5

L/S

V4

+ -

V1I

V2I

V1O

V2O

V5

V6

V6

V5

S4S3 D2

D1

S2V2

S1V1 c1 bc V2

V1

V4

V3

L1

230 V AC

N

AC

M

ATL

C 6

70-.

..A

NG

600

-...

AVA

670

-...

LAN

b1

Koa

x

a)m

)

IN

Dev

ice

requ

irem

ent

Rem

arks

Doo

r re

leas

e (T

ö) 1

2 V

AC

/DC

min

. 20

Ohm

8.1 Siedle Vario Video decoupler (camera in switching operation)

Page 81: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

81

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• The use of the potential-free switching outputs is described in separate diagrams.(For detailed information, see page 72, 74)

m) Where there are more than 10 BTM 650-… units, an addi-tional 12 V AC supply, for instance TR 603-…, must be installed due to the current consumption. To use the additional supply, the jumpers on the ATLM are removed from b1/c1 to b/c and the b/c terminals are directly connected to the additional supply. The jumpers for the ACM camera module between the terminals V3/V4 and the terminals b1/c1 remain as they are.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of an additional power supply is described in a separate diagram.(For detailed information, see page 76)

Page 82: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

82

Sied

le V

ario

ATL

M 6

70-.

..BT

M 6

50-.

..

AC

M 6

73-.

..

ATL

M

BTM

23 24 V1

D2

S2S1 S3 D1

S4V2

V3

V6

V5

L/S

V4

+ –

V1I

V2I

V1O

V2O

V5

V6

V6

V5

S4S3 D2

D1

S2V2

S1V1 c1 bc V2

V1

V4

V3

L1

230 V AC

N

AC

M

ATL

C 6

70-.

..A

NG

600

-...

AVA

670

-...

LAN

b1

Koa

x

a)c)

, m)

IN

Dev

ice

requ

irem

ent

Rem

arks

Doo

r re

leas

e (T

ö) 1

2 V

AC

/DC

min

. 20

Ohm

8.1 Siedle Vario Video decoupler (camera in continuous operation)

Page 83: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

83

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• The use of the potential-free switching outputs is described in separate diagrams.(For detailed information, see page 72, 74)

c) The camera used must be suitable for continuous operation. Alternatively, the camera must be used in switching operation. (For detailed information, see page 80)• In addition, the camera should only be used in continuous opera-tion within its permitted operating parameters (e.g. ambient tempera-ture).(For detailed information, see page 24)

m) Where there are more than 10 BTM 650-… units, an addi-tional 12 V AC supply, for instance TR 603-…, must be installed due to the current consumption. To use the additional supply, the jumpers on the ATLM are removed from b1/c1 to b/c and the b/c terminals are directly connected to the additional supply. The jumpers for the ACM camera module between the terminals V3/V4 and the terminals b1/c1 remain as they are.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of an additional power supply is described in a separate diagram.(For detailed information, see page 76)

Page 84: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

84

8.1 Siedle Vario External camera

Sied

le V

ario

ATL

M 6

70-.

..BT

M 6

50-.

..

ATL

M

BTM

L/S + -

+ -

N L1+ -

L/S

V6

23 24

V5

V4

V1

V3

V2

b1c1 cbV6

V5

V2

V1

S4 D2

D1

D2

D1

S1 S3S2

S4S1 S3S2

ATL

C 6

70-…

AN

G 6

00-…

CE

600-

…A

IVS

670-

...

b)

230 V AC

N L1

230 V AC

LAN

a)

NG

602

-…

j)w

)

IN

Rem

arks

Dev

ice

requ

irem

ent

Doo

r re

leas

e (T

ö)12

V A

C/D

Cm

in. 2

0 O

hm

Page 85: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

85

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• The use of the potential-free switching outputs is described in separate diagrams.(For detailed information, see page 72, 74)

b) Distance between the camera and AIVS 670-… max. 10 m

j) Where there are more than 26 BTM 650-… units, an addi-tional 12 V AC supply, for instance TR 603-…, must be installed due to the current consumption. To use the additional supply, the jumpers on the ATLM are removed from b1/c1 to b/c and the b/c terminals are directly connected to the additional supply.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of an additional power supply is described in a separate diagram.(For detailed information, see page 76)

w) Separate power supply required.

Page 86: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

86

8.1 Siedle Vario External camera and video decoupler

Sied

le V

ario

ATL

M 6

70-.

..BT

M 6

50-.

..

ATL

M

BTM

L/S + -

N L1+ -

L/S

V6

23 24

V5

V4

V1

V3

V2

cb V6

V5

V2

V1

S4 D2

D1

D2

D1

S1 S3S2

S4S1 S3S2

ATL

C 6

70-…

AN

G 6

00-…

CE

600-

…A

IVS

670-

...

b)

LAN

a)

AVA

670

-…

V1I

V2I

V1O

V2O

V6

V5

V4

V3

b1c1

+ -

L/S

NG

602

-…

N L1

w)

j)

IN

Dev

ice

requ

irem

ent

Rem

arks

Supp

ly v

olta

ge

48 V

DC

!C

oaxi

al

conn

ectio

nL

= le

adS

= s

hiel

d

230 V AC

230 V AC

Doo

r re

leas

e (T

ö)

12 V

AC

/DC

min

. 20

Ohm

Page 87: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

87

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• The use of the potential-free switching outputs is described in separate diagrams.(For detailed information, see page 72, 74)

b) Distance between the camera and AIVS 670-… max. 10 m

j) Where there are more than 26 BTM 650-… units, an addi-tional 12 V AC supply, for instance TR 603-…, must be installed due to the current consumption. To use the additional supply, the jumpers on the ATLM are removed from b1/c1 to b/c and the b/c terminals are directly connected to the additional supply.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of an additional power supply is described in a separate diagram.(For detailed information, see page 76)

w) Separate power supply required.

Page 88: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

88

8.1 Siedle Vario Code lock module as access control and direct dial

Sied

le V

ario

ATL

M 6

70-.

..BT

M 6

50-.

..C

OM

611

-...

AC

M 6

73-.

..

ATL

M

BTM

14 13

W2

V1

D2

S2S1 S3 D1

S4V2

V5

V6

V6

V5

S4S3 D2

D1

Da

Db

bcb

v

S2V2

S1V1 c1 c b

Da

W0

Db cv bv

b1

V2

V1

V4

V3

N L1N L1

230 V AC

230 V AC

AC

M

ATL

C 6

70-.

..A

NG

600

-...

TR 6

02-.

..EC

602

-...

LAN

cvC

OM

a)m

), o

)

TR 6

03-.

..

b c

r)t)

IN

Büch

ner

Cla

udia

Mai

er K

laus

Schu

hmac

her

Bern

dN

amen

such

e m

it

Rem

arks

Dev

ice

requ

irem

ent

Doo

r re

leas

e (T

ö) 1

2 V

AC

/DC

min

. 20

Ohm

Page 89: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

89

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• The use of the potential-free switching outputs is described in separate diagrams.(For detailed information, see page 72, 74)

m) Where there are more than 10 BTM 650-… units, an addi-tional 12 V AC supply, for instance TR 603-…, must be installed due to the current consumption. To use the additional supply, the jumpers on the ATLM are removed from b1/c1 to b/c and the b/c terminals are directly connected to the additional supply. The jumpers for the ACM camera module between the terminals V3/V4 and the terminals b1/c1 remain as they are.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of an additional power supply is described in a separate diagram.(For detailed information, see page 76)

o) The COM 611-… code lock module is always available for making calls (direct dial via numeric code).Together with the EC 602-… easikey controller, additional control func-tions (e.g. access control) can be car-ried out for this door station.

r) To ensure smooth operation, the COM 611-… code lock module and the EC 600-… easikey controller must be supplied with their own power supply.

t) If only control functions (access control) are run, the Da/Db terminals of the COM 611-… and EC 600-… must be connected directly to one another (without connection to D1/D2). Only in this case may the COM 611-…/ EC 600-… of the var-ious door stations be interconnected to a group. If no control functions are needed, then the COM 611-… code lock module can also be used without the EC 600-… easikey controller.

Page 90: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

90

8.1 Siedle Vario Display call module

Sied

le V

ario

ATL

M 6

70-.

..BT

M 6

50-.

..D

RM 6

12-.

..

AC

M 6

73-.

..

ATL

M

BTM

23 24 V1

D2

S2S1 S3 D1

S4V2

V5

V6

V6

V5

S4S3 D2

D1

Da

Db

W5

W6

bvS2V2

S1V1 c1 c bb1

V2

V1

V4

V3

N L1

230 V AC

AC

M

ATL

C 6

70-.

..A

NG

600

-...

N L1

230 V ACTR

603

-...

LAN

cvbc

W3

W4

DRM

a)n)

g),

m)

ZWA

640

-...

IN

Büch

ner

Cla

udia

Schu

hmac

her

Mic

hael

Nam

ensu

che

mit

OK

Mai

er K

laus

Büch

ner

Cla

udia

Schu

hmac

her

Mic

hael

Nam

ensu

che

mit

OK

Mai

er K

laus

Rem

arks

Dev

ice

requ

irem

ent

Doo

r re

leas

e (T

ö) 1

2 V

AC

/DC

min

. 20

Ohm

Page 91: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

91

Notes on the circuit diagramThe wiring of 2 door stations with a display call module each is described in a separate diagram(For detailed information, see page 92)

a) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• The use of the potential-free switching outputs is described in separate diagrams. (For detailed information, see page 72, 74)

g) To ensure smooth operation, the DRM 612-… display call module must be supplied with its own power supply.

m) Where there are more than 10 BTM 650-… units, an addi-tional 12 V AC supply, for instance TR 603-…, must be installed due to the current consumption. To use the additional supply, the jumpers on the ATLM are removed from b1/c1 to b/c and the b/c terminals are directly connected to the additional supply. The jumpers for the ACM camera module between the terminals V3/V4 and the terminals b1/c1 remain as they are.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of an additional power supply is described in a separate diagram.(For detailed information, see page 76)

n) For programming the names, pro-gramming software PRS 602-… and programming interface PRI 602-… are required. The names are now entered in the display call module using the PRS 602-… • The PRI 602-… is supplied via the power supply connected to the ZWA 640-…, (terminals W3/W4).

Page 92: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

92

8.1 Siedle Vario 2 door stations/display call modules

Sied

le V

ario

ATL

M 6

70-.

..BT

M 6

50-.

..D

RM 6

12-.

..

AC

M 6

73-.

..

ATL

M

BTM

23 24 V1

D2

S2S1 S3 D1

S4V2

V5

V6

V6

V5

S4S3 D2

D1

Da

Db

W5

W6

bvS2V2

S1V1 c1 c bb1

V2

V1

V4

V3

N L1

AC

M

ATL

C 6

70-.

..A

NG

600

-...

N L1

TR 6

03-..

.

cv

bc

W3

W4

DRM

a)n)

g),

m)

ZWA

640

-...

IN

Büch

ner

Cla

udia

Schu

hmac

her

Mic

hael

Nam

ensu

che

mit

OK

Mai

er K

laus

Büch

ner

Cla

udia

Schu

hmac

her

Mic

hael

Nam

ensu

che

mit

OK

Mai

er K

laus

Sied

le V

ario

ATL

M 6

70-.

..BT

M 6

50-.

..D

RM 6

12-.

..

AC

M 6

73-.

..

23 24 V1

D2

S2S1 S3 D1

S4V2

V5

V6

V6

V5

S4S3 D2

D1

Da

Db

W5

W6

bvS2V2

S1V1 c1 c bb1

V2

V1

V4

V3

N L1

ATL

C 6

70-.

..A

NG

600

-...

N L1

TR 6

03-..

.

cv

bc

W3

W4

a)n)

g),

m)

ZWA

640

-...

LAN

Büch

ner

Cla

udia

Schu

hmac

her

Mic

hael

Nam

ensu

che

mit

OK

Mai

er K

laus

LAN

PRI

PRI

Rem

arks

Dev

ice

requ

irem

ent

Doo

r st

atio

n 1

Doo

r st

atio

n 2

230 V AC

230 V AC

230 V AC

230 V AC

Doo

r re

leas

e (T

ö) 1

2 V

AC

/DC

min

. 20

Ohm

Doo

r re

leas

e (T

ö) 1

2 V

AC

/DC

min

. 20

Ohm

Page 93: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

93

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• The use of the potential-free switching outputs is described in separate diagrams.(For detailed information, see page 72, 74)

g) To ensure smooth operation, the DRM 612-… display call module must be supplied with its own power supply.

m) Where there are more than 10 BTM 650-… units, an addi-tional 12 V AC supply, for instance TR 603-…, must be installed due to the current consumption. To use the additional supply, the jumpers on the ATLM are removed from b1/c1 to b/c and the b/c terminals are directly connected to the additional supply. The jumpers for the ACM camera module between the terminals V3/V4 and the terminals b1/c1 remain as they are.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of an additional power supply is described in a separate diagram.(For detailed information, see page 76)

n) For programming the names, pro-gramming software PRS 602-… and programming interface PRI 602-… are required. The names are now entered in the display call module using the PRS 602-… • The PRI 602-… is supplied via the power supply connected to the ZWA 640-…, (terminals W3/W4).

In the case of several door stations, the wiring of one door station must not be connected to the wiring of another door station (bridged).

Page 94: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

94

8.1 Siedle Vario Radio chime

c b N L1

Sied

le V

ario

TR 6

03-.

..

ATL

M 6

70-.

..BT

M 6

50-.

..

AC

M 6

73-.

..

ATL

M

BTM

23 24 V1

D2

S2S1 S3 D1

S4V2

V5

V6

V6

V5

S4S3 D2

D1

S2V2

S1V1 c1 bc V2

V1

V4

V3

L1N

AC

M

ATL

C 6

70-.

..A

NG

600

-...

LAN

a)m

)b1

45

IN/O

UT

36

RJ45

8/8

G D

LAN

AH

FV 8

70-…

AH

TV 8

70-…

AV

P 87

0-…

u)u)

RTS1

7

230 V AC

230 V AC

IN

Rem

arks

Dev

ice

requ

irem

ent

Tele

com

soc

ket

Radi

o tr

ansm

itter

Stor

ey c

all b

utto

n

Doo

r re

leas

e (T

ö)12

V A

C/D

C m

in. 2

0 O

hm

Page 95: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

95

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• The use of the potential-free switching outputs is described in separate diagrams. (For detailed information, see page 72, 74)

m) Where there are more than 10 BTM 650-… units, an addi-tional 12 V AC supply, for instance TR 603-…, must be installed due to the current consumption. To use the additional supply, the jumpers on the ATLM are removed from b1/c1 to b/c and the b/c terminals are directly connected to the additional supply. The jumpers for the ACM camera module between the terminals V3/V4 and the terminals b1/c1 remain as they are.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of an additional power supply is described in a separate diagram.(For detailed information, see page 76)

u) To use the RTS17 radio trans-mitter, the secondary signal unit aux-iliary script must be imported into the Access server and the affected indoor station must be configured. Incoming calls are signalled on the indoor station and on the plug-in socket pager.

Page 96: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

96

8.1 Siedle Vario Basic circuit diagram (Audio)

Sied

le V

ario

ATL

M 6

70-.

..BT

M 6

50-.

..

ATL

M

BTM

N111214 L1

23 24

c1b1 bc

S4 D2

D1

D2

D1

S1 S3S2

S4S1 S3S2

ATL

C 6

70-.

..A

NG

600

-...

230 V AC

LAN

a)j)

IN

Rem

arks

Dev

ice

requ

irem

ent

Doo

r re

leas

e (T

ö) 1

2 V

AC

/DC

min

. 20

Ohm

Page 97: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

97

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• The use of the potential-free switching outputs is described in separate diagrams.(For detailed information, see page 72, 74)

j) Where there are more than 26 BTM 650-… units, an addi-tional 12 V AC supply, for instance TR 603-…, must be installed due to the current consumption. To use the additional supply, the jumpers on the ATLM are removed from b1/c1 to b/c and the b/c terminals are directly connected to the additional supply.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of an additional power supply is described in a separate diagram.(For detailed information, see page 76)

Page 98: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

98

8.2 Access custom-fit door loudspeaker Access camera module

ATL

E

BRM

A

ATL

C 6

70-.

..

6 7.1

7.2

7.3

7.11

230 V AC

N L1

AN

G 6

00-.

..

7.12

V6

23 24

V5

D2

S2S1 D1

S4S3

V5

V4

V1

V3

c1b1

V2

V2

V1

S4 D2

D1

S1 S3S2

LAN

a)d)

AC

M 6

73-.

..

IN

Dev

ice

requ

irem

ent

Rem

arks

Cus

tom

-fit

door

loud

spea

ker

ATL

E 67

0-...

BRM

A 0

50-.

..

Doo

r re

leas

e (T

ö) 1

2 V

AC

/DC

min

. 20

Ohm

Page 99: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

99

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• The use of the potential-free switching outputs is described in separate diagrams.(For detailed information, see page 72, 74)

d) A maximum of 12 call but-tons can be connected at one BRMA 050-…The maximum configuration is 16 BRMA 050-… units/192 buttons.

Page 100: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

100

8.2 Access custom-fit door loudspeaker External camera

ATL

E

BRM

A

b)

ATL

C 6

70-.

..

c1 6 7.1

7.2

7.3

7.11

L/S + -

230 V AC

N L1

AN

G 6

00-.

..

+ -

L/S

7.12

V6

23 24

V5

D2

S2S1 D1

S4S3

V5

V4

V1

V3

V2

V2

V1

S4 D2

D1

S1 S3S2

CE

600-

…A

IVS

670-

...

LAN

a)d)

+ - N L1

230 V ACN

G 6

02-…

w)

IN

Dev

ice

requ

irem

ent

Rem

arks

Cus

tom

-fit

door

loud

spea

ker

ATL

E 67

0-...

BRM

A 0

50-.

..

Doo

r re

leas

e (T

ö)

12 V

AC

/DC

min

. 20

Ohm

Page 101: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

101

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• The use of the potential-free switching outputs is described in separate diagrams.(For detailed information, see page 72, 74)

b) Distance between the camera and AIVS 670-… max. 10 m

d) A maximum of 12 call but-tons can be connected at one BRMA 050-…The maximum configuration is 16 BRMA 050-… units/192 buttons.

w) Separate power supply required.

Page 102: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

102

8.2 Access custom-fit door loudspeaker Basic circuit diagram (Audio)

ATL

E

BRM

A

ATL

C 6

70-.

..

6 7.1

7.2

7.3

7.11

230 V AC

N L1

AN

G 6

00-.

..

7.12

23 24

D2

S2S1 D1

S4S3

S4 D2

D1

S1 S3S2

LAN

d)a)

IN

Rem

arks

Acc

ess

cust

om-fi

t do

or lo

udsp

eake

rA

TLE

670-

...BR

MA

050

-...

Dev

ice

requ

irem

ent

Doo

r re

leas

e (T

ö) 1

2 V

AC

/DC

min

. 20

Ohm

Page 103: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

103

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• The use of the potential-free switching outputs is described in separate diagrams.(For detailed information, see page 72, 74)

d) A maximum of 12 call but-tons can be connected at one BRMA 050-…The maximum configuration is 16 BRMA 050-… units/192 buttons.

Page 104: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

104

ACM

ATLE

BRMA

Tö 12 V ACmin. 20 Ohm

ATLC 670-...

c1

6

7.1

7.2

7.3

7.11

230

V A

C

N

L1

ANG 600-...

+-

7.12

V2

23

24

V5

D2

S2

S1

D1

S4

S3

V1

V4

V5

V3

V6

V2

V1

S4

D2

D1

S1

S3

S2

LAN

a)d)

IN

Gerätebedarf

Hinweise

Classic TürstationACM 670-...ATLE 670-...BRMA 050-...

l), q) y)Remarks

8.3 Siedle Classic Wiring diagram for call buttons

Page 105: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

105

Notes on the circuit diagraml) The internal wiring of the Classic door station is completed on site by the customer.

q) Where there are more than 20 backlit call buttons, an additional 12 V AC supply, for instance TR 603-…, must be installed due to the current consumption. To use the additional supply, the jumpers between the CATLE and the call but-tons from b1/c1 to b/c are removed and the b/c terminals are directly connected to the additional supply. The jumpers from the ACM camera module to CATLE between the ter-minals V3/V4 and the terminals b1/c1 remain as they are.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)

y) The circuit diagram shows an exemplary connection of call buttons with the BRMA.• The call button modules come in designs with 1, 2, 3 and 4 buttons. On all call button modules with more than one button, all terminals 6… are internally bridged on the call button module. The jumpers can be removed if required.• If more than 4 call buttons are required, the call button modules are cascaded accordingly (e.g. 7 call buttons = call button module with 4 and 3 call buttons).• If there is more than one call button module, then at least one of the terminal 6… must be connected straight through between all call button modules.

Call button module

Button Terminal designations for the button

Button back-lighting

1 Button 1 6 7 b, c

2 Buttons 1 6.1 7.1 b, c

2 6.2 7.2

3 Buttons 1 6.1 7.1 b, c

2 6.2 7.2

3 6.3 7.3

4 Buttons 1 6.1 7.1 b, c

2 6.2 7.2

3 6.3 7.3

4 6.4 7.4

Example: In the case of 7 call but-tons, terminal 6.1 of the first call button module is bridged with ter-minal 6.1 of the second call button (see wiring diagram). Terminals 6… are bridged with one another on each call button module and do not need to be additionally wired/bridged (exception: A button is used independently as a potential-free contact and the jumpers have been disconnected).

Page 106: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

106

ACM

ATLE

BRMA

Tö 12 V ACmin. 20 Ohm

ATLC 670-...

c1

6

7.1

7.2

7.3

7.11

230

V A

C

N

L1

ANG 600-...

+-

7.12

V2

23

24

V5

D2

S2

S1

D1

S4

S3

V1

V4

V5

V3

V6

V2

V1

S4

D2

D1

S1

S3

S2

LAN

a)d)

IN

Gerätebedarf

Hinweise

Classic TürstationACM 670-...ATLE 670-...BRMA 050-...

CA

CM

CA

TLE

BRM

A

ATL

C 6

70-.

..

c1 6 7.1

7.2

7.3

7.11

230 V AC

N L1

AN

G 6

00-.

..

b1

7.12V2

23 24

V5

D2

S2S1 D1

S4S3V1

V4

V6

V3

V5

V2

V1

S4 D2

D1

S1 S3S2

LAN

a)

Sied

le C

lass

icC

AC

M 6

73-.

..C

ATL

E 67

0-...

BRM

A 0

50-.

..

l), q

)

Sied

le C

lass

ic

y)

IN

Dev

ice

requ

irem

ent

Rem

arks

Doo

r re

leas

e (T

ö) 1

2 V

AC

/DC

min

. 20

Ohm

Cal

l but

tons

8.3 Siedle Classic Basic circuit diagram (Video)

Page 107: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

107

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• The use of the potential-free switching outputs is described in separate diagrams.(For detailed information, see page 72, 74)

l) The internal wiring of the Classic door station is completed on site by the customer.• The connection of the call button modules is described in a separate diagram. (For detailed information, see page 104)

q) Where there are more than 20 backlit call buttons, an additional 12 V AC supply, for instance TR 603-…, must be installed due to the current consumption. To use the additional supply, the jumpers between the CATLE and the call but-tons from b1/c1 to b/c are removed and the b/c terminals are directly connected to the additional supply. The jumpers from the ACM camera module to CATLE between the ter-minals V3/V4 and the terminals b1/c1 remain as they are.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of an additional power supply is described in a separate diagram.(For detailed information, see page 76)

y) The circuit diagram shows an exemplary connection of call buttons with the BRMA.• (For detailed information, see page 105)

Page 108: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

108

8.3 Siedle ClassicVideo decoupler (camera in continuous operation)

Sied

le C

lass

ic

CA

TLE

670-

...BR

MA

050

-...

CA

CM

673

-...

CAT

LE

BRM

A

23 24V1

D2

S2S1 S3 D1

S4V2

V3

V6

V5

L/S

V4

+ –

V1I

V2I

V1O

V2O

V5

V6

V5

S4S3 D2

D1

S2V1

S1V2 c1V4

V3

L1

230 V AC

N

ATL

C 6

70-.

..A

NG

600

-...

AVA

670

-...

LAN

b1

Koa

x

a)i),

q)

CA

CM

6 7.1

7.2

7.3

7.11

7.12

y)Sied

le C

lass

ic

IN

Dev

ice

requ

irem

ent

Rem

arks

Doo

r re

leas

e (T

ö) 1

2 V

AC

/DC

min

. 20

Ohm

Cal

l but

tons

Page 109: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

109

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• The use of the potential-free switching outputs is described in separate diagrams.(For detailed information, see page 72, 74)

i) The camera used must be suitable for continuous operation. Alternatively, the camera must be used in switching operation.• In addition, the camera should only be used in continuous opera-tion within its permitted operating parameters (e.g. ambient tempera-ture).(For detailed information, see page 24)

q) Where there are more than 20 backlit call buttons, an additional 12 V AC supply, for instance TR 603-…, must be installed due to the current consumption. To use the additional supply, the jumpers between the CATLE and the call but-tons from b1/c1 to b/c are removed and the b/c terminals are directly connected to the additional supply. The jumpers from the ACM camera module to CATLE between the ter-minals V3/V4 and the terminals b1/c1 remain as they are.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of an additional power supply is described in a separate diagram.(Examples: For detailed information, see page 76)

y) The circuit diagram shows an exemplary connection of call buttons with the BRMA.• (For detailed information, see page 105)

Page 110: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

110

8.3 Siedle Classic 2 mail notification systems

ACM

ATLE

BRMA

Tö 12 V ACmin. 20 Ohm

ATLC 670-...

c1

6

7.1

7.2

7.3

7.11

230

V A

C

N

L1

ANG 600-...

+-

7.12

V2

23

24

V5

D2

S2

S1

D1

S4

S3

V1

V4

V5

V3

V6

V2

V1

S4

D2

D1

S1

S3

S2

LAN

a)d)

IN

Gerätebedarf

Hinweise

Classic TürstationACM 670-...ATLE 670-...BRMA 050-...

ACM

ATLE

BRMA

Tö 12 V ACmin. 20 Ohm

ATLC 670-...

c1

6

7.1

7.2

7.3

7.11

230

V A

C

N

L1

ANG 600-...

+-

7.12

V2

23

24

V5

D2

S2

S1

D1

S4

S3

V1

V4

V5

V3

V6

V2

V1

S4

D2

D1

S1

S3

S2

LAN

a)d)

IN

Gerätebedarf

Hinweise

Classic TürstationACM 670-...ATLE 670-...BRMA 050-...

CA

CM

CA

TLE

BRM

A

ATL

C 6

70-.

..

c1 6 7.1

7.2

7.3

7.11

230 V AC

N L1

AN

G 6

00-.

..

b1

7.12V2

23 24V

5

D2

S2S1 D1

S4S3V1

V4

V6

V3

V5

V2

V1

S4 D2

D1

S1 S3S2

LAN

a)

Sied

le C

lass

icC

AC

M 6

73-.

..C

ATL

E 67

0-...

BRM

A 0

50-.

..

l), q

)

ATL

CE

670-

...

1615

1615

PME

600-

...PM

E 60

0-...

1615

1615 bc

bc

x)x)

230 V AC

N L1bc

TR 6

03-.

..

w)

Sied

le C

lass

ic

y)

IN

Dev

ice

requ

irem

ent

Rem

arks

Doo

r re

leas

e (T

ö) 1

2 V

AC

/DC

min

. 20

Ohm

Cal

l but

tons

Page 111: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

111

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.The use of the potential-free switching outputs is described in separate diagrams.(For detailed information, see page 72, 74)

l) The internal wiring of the Classic door station is completed on site by the customer.The connection of the call button modules is described in a separate diagram. (For detailed information, see page 104)

q) Where there are more than 20 backlit call buttons, an additional 12 V AC supply, for instance TR 603-…, must be installed due to the current consumption. To use the additional supply, the jumpers between the CATLE and the call but-tons from b1/c1 to b/c are removed and the b/c terminals are directly connected to the additional supply. The jumpers from the ACM camera module to CATLE between the ter-minals V3/V4 and the terminals b1/c1 remain as they are.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of an additional power supply is described in a separate diagram.(For detailed information, see page 76)

w) Separate power supply required.

x) A separate potential-free switching input is required for each mail notification system. You must configure each switching input in the Access administration interface. You can run up to 7 mail notifica-tion systems with the fully extended system (1 ATLC and 3 ATLCEs).

y) The circuit diagram shows an exemplary connection of call buttons with the BRMA.• (For detailed information, see page 105)

Page 112: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

112

8.3 Siedle Classic Code lock module as access control and direct dial

Sied

le C

lass

ic

CA

TLE

670-

...BR

MA

050

-...

CO

M 6

11-.

..

CA

CM

673

-...

CA

TLE

BRM

A

14 13

W2

V1

D2

S2S1 S3 D1

S4V2

c1V5

V5

V6

S4S3 D2

D1

Da

Db

bcb

vS2V1

S1V2

b1

Da

W0

Db cv bv

V4

V3

N L1N L1

230 V AC

230 V AC

CA

CM

ATL

C 6

70-.

..A

NG

600

-...

TR 6

02-.

..EC

602

-...

LAN

cvC

OM

a)o)

, q)

TR 6

03-.

..

b c

r)t)

7.3

7.2

7.117.16

7.12

Sied

le C

lass

ic

y)

IN

Rem

arks

Device

requ

iremen

t

Doo

r re

leas

e (T

ö) 1

2 V

AC

/DC

min

. 20

Ohm

Cal

l but

tons

Page 113: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

113

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.The use of the potential-free switching outputs is described in separate diagrams.(For detailed information, see page 72, 74)

o) The COM 611-… code lock module is always available for making calls (direct dial via numeric code).Together with the EC 602-… easikey controller, additional control func-tions (e.g. access control) can be car-ried out for this door station.

q) Where there are more than 20 backlit call buttons, an additional 12 V AC supply, for instance TR 603-…, must be installed due to the current consumption. To use the additional supply, the jumpers between the CATLE and the call but-tons from b1/c1 to b/c are removed and the b/c terminals are directly connected to the additional supply. The jumpers from the ACM camera module to CATLE between the ter-minals V3/V4 and the terminals b1/c1 remain as they are.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of an additional power supply is described in a separate diagram.(Examples: For detailed information, see page 76)

r) To ensure smooth operation, the COM 611-… code lock module and the EC 600-… easikey controller must be supplied with their own power supply.

t) If only control functions (access control) are run, the Da/Db terminals of the COM 611-… and EC 600-… must be connected directly to one another (without connection to D1/D2). Only in this case may the COM 611-…/ EC 600-… of the var-ious door stations be interconnected to a group. If no control functions are needed, then the COM 611-… code lock module can also be used without the EC 600-… easikey controller.

y) The circuit diagram shows an exemplary connection of call buttons with the BRMA.• (For detailed information, see page 105)

Page 114: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

114

Siedle Steel

SATLM 670-...SACM 673-...

SATLM

23

24

V1

D2

S2

S1

S3

D1

S4

V2

S4

S3

D2

D1

S2

S1

V2

V1

N

L1

230

V A

C

SACM

ATLC 670-...ANG 600-...

LAN

a)Remarks

Devicerequirement

Buttons

Door release (Tö) 12 V AC/DCmin. 20 Ohm

8.4 Siedle Steel Basic circuit diagram (Video)

Page 115: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

115

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of the potential-free switching outputs is described in separate diagrams.(For detailed information, see page 72, 74)

Page 116: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

116

8.4 Siedle Steel Video decoupler (camera in continuous operation)

Sied

le S

teel

SATL

M 6

70-.

..SA

CM

673

-...

SATL

M

23 24 V1

D2

S2S1 S3 D1

S4V2

V3

V6

V5

L/S

V4

+ –

V1I

V2I

V1O

V2O

V5

V6

V6

V5

S4S3 D2

D1

S2V2

S1V1 c1 bc V2

V1

V4

V3

L1

230 V AC

N

ATL

C 6

70-.

..A

NG

600

-...

AVA

670

-...

LAN

b1

Koa

x

a)i),

z)

SAC

M

Dev

ice

requ

irem

ent

Rem

arks

Doo

r re

leas

e (T

ö) 1

2 V

AC

/DC

min

. 20

Ohm

Butt

ons

Page 117: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

117

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of the potential-free switching outputs is described in separate diagrams.(Examples: For detailed information, see page 72, 74)

i) The camera used must be suitable for continuous operation. Alternatively, the camera must be used in switching operation.• In addition, the camera should only be used in continuous opera-tion within its permitted operating parameters (e.g. ambient tempera-ture).(For detailed information, see page 24)

z) Before wiring, the 6-pole ribbon cable between the connection pcb SACM and the connection pcb SATLM must be removed.

Page 118: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

118

8.4 Siedle Steel 2 mail notification systems

SAC

M

ATL

C 6

70-.

..

230 V AC

N L1

AN

G 6

00-.

..

V2

23 24

D2

S2S1 D1

S4S3V1

V2

V1

S4 D2

D1

S1 S3S2

LAN

a)

Sied

le S

teel

SAC

M 6

73-.

..SA

TLM

670

-...

ATL

CE

670-

...

1615

1615

PME

600-

...PM

E 60

0-...

1615

1615 bc

bc

x)x)

230 V AC

N L1bc

TR 6

03-.

..

w)

SATL

M

Dev

ice

requ

irem

ent

Rem

arks

Butt

ons

Doo

r re

leas

e (T

ö) 1

2 V

AC

/DC

min

. 20

Ohm

Page 119: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

119

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of the potential-free switching outputs is described in separate diagrams.(For detailed information, see page 72, 74)

w) Separate power supply required.

x) A separate potential-free switching input is required for each mail notification system.• You must configure each switching input in the Access administration interface.• You can run up to 7 mail notifica-tion systems with the fully extended system (1 ATLC and 3 ATLCEs).

Page 120: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

120

8.4 Siedle Steel Code lock module as access control and direct dial

Sied

le S

teel

SATL

M 6

70-.

..C

OM

611

-...

SAC

M 6

73-.

..

SATL

M

14 13

W2

V1

D2

S2S1 S3 D1

S4V2

S4S3 D2

D1

Da

Db

bcb

vS2V1

S1V2

Da

W0

Db cv bv

N L1N L1

230 V AC

230 V AC

SAC

M

ATL

C 6

70-.

..A

NG

600

-...

TR 6

02-.

..EC

602

-...

LAN

cvC

OM

a)o)

TR 6

03-.

..

b c

r)t)

Rem

arks

Device

requ

iremen

t

Butt

ons

Doo

r re

leas

e (T

ö) 1

2 V

AC

/DC

min

. 20

Ohm

Page 121: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

121

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of the potential-free switching outputs is described in separate diagrams.(For detailed information, see page 72, 74)

o) The COM 611-… code lock module is always available for making calls (direct dial via numeric code).Together with the EC 602-… easikey controller, additional control func-tions (e.g. access control) can be car-ried out for this door station.

r) To ensure smooth operation, the COM 611-… code lock module and the EC 600-… easikey controller must be supplied with their own power supply.

t) If only control functions (access control) are run, the Da/Db terminals of the COM 611-… and EC 600-… must be connected directly to one another (without connection to D1/D2). Only in this case may the COM 611-…/ EC 600-… of the var-ious door stations be interconnected to a group. If no control functions are needed, then the COM 611-… code lock module can also be used without the EC 600-… easikey controller.

Page 122: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

122

SATL

M

ATL

C 6

70-.

..

N L1

AN

G 6

00-.

..

+ -

N L1

TR 6

03-.

..

b c

23 24

D2

S2S1 D1

S4S3cb V4

V1

V3

V2

V2

V1

S4 D2

D1

S1 S3S2

AIV

SE

LAN

SVTM

C

Sied

le S

teel

SVTM

C 6

40-.

.. +

AIV

SE 6

70-…

SATL

M 6

70-.

..

a)

Dev

ice

requ

irem

ent

230 V AC

230 V AC

Rem

arks

Doo

r rel

ease

12

V A

C/D

Cm

in. 2

0 O

hm

Butt

ons

8.4 Siedle Steel Flush mounted camera

Page 123: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

123

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of the potential-free switching outputs is described in separate diagrams.(For detailed information, see page 72, 74)

Page 124: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

124

SATLM

ATLC 670-...

N

L1

ANG 600-...

N

L1

TR 603-...

c

b

23

24

D2

S2

S1

D1

S4

S3

V1

V2 V2

V1

S4

D2

D1

S1

S3

S2

LAN

SACM

Siedle SteelSACM 673-...SATLM 670-...SDRM 612-...

SDRM W4

W3

W6

W5

PRI

Da

Db

cv

bv

ZWA 640-...

g) a)n)

Büchner Claudia

Schuhmacher Michael

Namensuche mit

OK

Maier Klaus

Büchner Claudia

Schuhmacher Michael

Namensuche mit

OK

Maier Klaus

Devicerequirement

230

V A

C

230

V A

C

Remarks

Door release (Tö) 12 V AC/DCmin. 20 Ohm

8.4 Siedle Steel Display call module

Page 125: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

125

Notes on the circuit diagrama) If door releases or gate control systems are fitted and their con-nected values do not correspond to 12 V AC/DC and min. 20 Ohm, then either switching output 2 (ATLC ter-minals 13/14 (output)) or switching output 3 (ANG terminals 11/12/14 (output)) can be used as a potential-free door release contact.To use switching output 2 or 3 as a potential-free door release contact, you must configure the corre-sponding ATLC switching output in the Access administration interface.• Supply limits ATLC/NG 670-… (For detailed information, see page 9)• The use of the potential-free switching outputs is described in separate diagrams.(For detailed information, see page 72, 74)

g) To ensure smooth operation, the DRM 612-… display call module must be supplied with its own power supply.

n) For programming the names, pro-gramming software PRS 602-… and programming interface PRI 602-… are required. The names are now entered in the display call module using the PRS 602-… • The PRI 602-… is supplied via the power supply connected to the ZWA 640-…, (terminals W3/W4).

Page 126: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

126

y)p)

ATL

C 6

70-.

..

L/S

E D A

+ -

+ -

230 V AC

N L1

AN

G 6

00-.

..

230 V AC

N L1

NG

602

-...

+ -

L/S

V5

V6

V4

V1

V3

V2

V2

V1

CE

600-

...A

IVS

670-

...

LAN

Vid

eo

Rem

arks

Dev

ice

requ

irem

ent

Vid

eo

dist

ribut

or

8.5 Camera connection External camera with video distributor

Page 127: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

127

FunctionalViewing/monitoring a certain area using an Access indoor call station set up for the purpose.Each camera is specifically selected via the ATLC 670-… The number of cameras/Access users is limited by the server used.Using the buttons defined during configuration, each camera can be selected. This function must be con-figured for every authorized user.The video signal is split using the video distributor supplied by the cus-tomer. This allows the signal to be shown on a continuous surveillance monitor and also on an event-con-trolled basis on an assigned Access indoor device.Terminal assignment of the video distributor provided by the customer: E = Input D = Throughput A = Output

Notes on the circuit diagramp) Camera in continuous operationThe camera used must be suit-able for continuous operation. Alternatively, the camera must be used in switching operation. (For detailed information, see page 80)• In addition, the camera should only be used in continuous opera-tion within its permitted operating parameters (e.g. ambient tempera-ture).(For detailed information, see page 24)

y) Distance between the camera and AIVS 670-… max. 10 m

Page 128: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

128

8.5 Camera connection External camera

p)y)

ATL

C 6

70-.

..

L/S + -

+ -

230 V AC

N L1

AN

G 6

00-.

..

230 V AC

N L1

NG

602

-...

+ -

L/S

V5

V6

V4

V1

V3

V2

V2

V1

CE

600-

...A

IVS

670-

...

LAN

Rem

arks

Dev

ice

requ

irem

ent

Page 129: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

129

FunctionalViewing/monitoring a certain area using an Access indoor call station set up for the purpose.Each camera is specifically selected via the ATLC 670-… The number of cameras/Access users is limited by the server used.Using the buttons defined during configuration, each camera can be selected. This function must be con-figured for every authorized user.

Notes on the circuit diagramp) Camera in continuous operationThe camera used must be suit-able for continuous operation. Alternatively, the camera must be used in switching operation. (For detailed information, see page 80)• In addition, the camera should only be used in continuous opera-tion within its permitted operating parameters (e.g. ambient tempera-ture).(For detailed information, see page 24)

y) Distance between the camera and AIVS 670-… max. 10 m

Page 130: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

130

8.6 Storey call button Customer-side signalling device

4

5

RJ45 8/8

LAN

e)

ERT3

6

Remarks

Devicerequirement

RJ45 8/8

LAN

ERT3

6

4

5

1

2

7

8

e), f)Remarks

Devicerequirement

Notes on the circuit diagrame) A suitable intermediate relay may be required for the customer’s own existing signalling device.

f) By mounting accessory AZIO 870-… terminals 1 and 2 as well as 7 and 8 of the right-hand RJ45 telecom socket are occupied, as listed in the terminal assignment. The terminal assignment changes if a different accessory is mounted.

Terminal assignment RJ45

Left RJ45 socket

1–8 LAN (Access)

Right RJ45 socket

3, 6 Storey call button ERT

4, 5 switching contact 30 V AC/DC, 1 A

1, 2 input via potential-free contact

7, 8 switching contact 30 V AC/DC, 1 A

Page 131: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

131

An indoor device may only be con-nected to the network using an RJ45 8/8 (8) network socket or RJ45 socket modules 8(8).

The connection between the junc-tion box and the circuit board of the indoor station is established with the RJ45 connectors included in the scope of supply.First connect the RJ45 plug with the circuit board and then with the junc-tion box.

Page 132: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

132

Commissioning Coordination/initial commissioning of an Access system should be performed by Siedle or an Access Certified Partner. The system must be ready installed, documented and made ready for operation (see com-missioning requirements) by the date of commissioning.Access to all parts of the system must be guaranteed, the system administrator must be available. Commissioning is performed against a charge. The relevant charging rates are shown in the quotation/the com-missioning form sheet.The Access system is configured using a computer running the cur-rent Firefox browser on the Access server. The necessary configuration is carried out directly on the Access server using the web user interface. Any necessary support for configura-tion-related questions can be found in the commissioning instructions or the Access help function. Careful documentation of the system and any configuration-related require-ments with an indication of the device mounting locations are par-ticularly helpful and should be made a constituent part of the operating manual without fail.

Commissioning requirements Installation• The installation complies with structured cabling requirements as outlined in DIN 50173-1/2/3/4. A suitable network plan is provided• All necessary network connections are available• The cabling complies with at least Category 5

Network requirements: • Separate physical network or VLAN with quality of service (IEEE802.1p)* • Active network components fea-ture Ethernet technology • Minimum network requirement: 100Base Tx • Consistent multicast-capable network • Connection of indoor devices to conventional network sockets • The use of switches is a prerequi-site (no hubs in the network) • The Access indoor call stations (AHT/AHTV/AHF/AHFV/AVP) require PoE-capable switches or PoE injec-tors to IEEE802.3af • Broadband requirement approx. 1 Mbit per connection

* The perfect operational reliability of a VLAN integration can only be ensured by agreement with the Access Service Center (ASC).

Call number table • (who is calling whom and how) is available, KNX configuration is clarified• Required key configuration avail-able

9 Commissioning and operation

Commissioning encompasses the following services• Review of submitted documents• Initialization of the system (server)• Identification and assignment of devices used, licensing arrangements• Set-up and configuration of door stations• Set-up and configuration of indoor stations• Set-up and configuration of soft-ware clients• Set-up and configuration of gateways (connection of non-Siedle devices)• Instruction and data transfer to the administrator/user on site

Commissioning instruction The commissioning process for the Access system is described in detail in the Access server commissioning instructions which can be found in the Siedle download area.

Page 133: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

133

Recommendation

• Be aware of inrush currents, including when power is restored after power failures. • Protect max. 6 ATLC/NG 670-… with a B 16A circuit breaker; if necessary, an appropriate inrush cur-rent limiter must be provided by the customer.• To prevent supply problems, we recommend the use of PoE switches which can supply each PoE port according to standard “IEEE 802.3af” with up to PoE class 3.

Access indoor station PoE class

AHF 870-…/AHFV 870-… 2

AHT 870-…/AHTV 870-… 2

AVP 870-… 3

Operating manual To ensure that you can retrace the status of a system at any time, an operating manual should be drawn up and regularly maintained.Siedle recommends compiling an operating manual to document the network and the Access system.The operating manual must be accessible to servicing personnel and contain fundamental information:• Contact data of the system admin-istrator (with deputization arrange-ments)• Hardware list• Documentation of the server con-figuration• Server backup• Documentation of the software status and device configuration• Construction plan with structured cabling (LAN policy)• Issue of passwords and possibilities for remote login access• IP address and device names of the network components

• Process descriptions (e.g. creating a user, exchanging devices etc.)• Documentation of changes made• Documentation of errors/remedy of errors

Updates and maintenance

During the update process, the power supply to the devices must not be interrupted, as this can result in damage. In this case, a repeat update is no longer possible, and the devices will have to be sent in for repair.

The software for all Siedle Access products with network connection is capable of updating.The updates for system components can be centrally imported via the Access server (from Access server V 3.0 and above as installer).From Access-Server V 3.0 and above, the system software and updates are supplied to the market solely by the Access Certified Partners (http://www.siedle.com/mysiedle).New Access performance features are also announced at www.siedle.com.The software status of the Access system must be recorded in the operating manual. Ensure that the active network components (switches, routers, firewall) are working with the latest software status.Siedle Access permits system access by remote login for maintenance and troubleshooting.For this purpose, online access to the Access server is required.

Maintenance contract With Access Professional V 4.0.0 and upwards, the field “End main-tenance contract” is located on the dashboard of the Access administra-tion user interface. The relevant date indicates up to when the customer will receive automatic updates/upgrades and can carry out a system update. The maintenance period is initially 1 year after first commis-sioning of the Access server for all systems. After this, all customers can decide whether they wish to extend the maintenance period for their system by paying for an extended maintenance contract. Alternatively a fee is payable for every update/upgrade.Maintenance contracts for the Siedle Access system can be pur-chased both through the Siedle Project Sales and through an Access Certified Partner (ACP).

Page 134: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

134

10 Servicing

Service requirement Access systems are serviced by the regional Access Certified Partner (service specialists). Customers/administrators request this services as the need arises.For services specialists, access must be afforded to all parts of the system at all times. The administrator and all necessary documents appertaining to the system must be available for the duration of the servicing work.

Warranty Siedle only provides a guarantee for configurable functions and system properties on hardware and soft-ware supplied by Siedle if commis-sioning was carried out by the Siedle Access Service Centre or our Access Certified Partners and this can be verified.Statutory rights for the delivery of defect-free goods are not affected.All system components which are designed for/suitable for installation in an electrical distribution board or in an IT cabinet system/housing may only be installed in the permitted installation position according to the enclosed product information.If system components are operated in improper installation positions or with improper operating parameters (e.g. excessive ambient tempera-ture), this will render their warranty rights void in the event of service.

Exchanging devices All devices which are connected directly to the network (indoor devices and ATLC 670-…) can be exchanged in running operation.Procedure:The administrator overwrites the MAC address for the device with the MAC address of the new replace-ment device in the server.Exchange the defective device.The configuration remains unchanged, making the function identical with the predecessor device.

Exchanging ATLM/ATLE 670-… Procedure:• Only the line rectifier which sup-plies the ATLC 670-… has to be disconnected from the mains. The Access system can remain opera-tional.• Exchange the defective ATLM/ATLE 670-…• Switch the line rectifier back on.• The system is now completely ready to resume operation. No con-figuration is required.

Exchanging a defective server AS 670-…/ASH 670-… Procedure:1 Sever all connections to the mains and the power supply.2 Exchange the defective server and restore all the connections3 Set up the supplied licences on the new server4 Restore the backup of the current configuration. If no backup exists, the system must be reconfigured.

Update process The update is initialised by the administrator and centrally executed at the server for all the devices. It is not possible to carry out a single update for an individual indoor device or server.During the update process, the entire system is non-operational. No calls or functions can be initiated or received. Updates should therefore be carried out during periods of minimal activity and with sufficient advance notice. All buttons flash yellow to visually indicate that the indoor devices are being updated. After the update is complete, the devices are automatically restarted.During the update process, the power supply to the devices must not be interrupted, as this can result in damage. In this case, a repeat update is no longer possible, and the devices will have to be sent in for repair.

Start process The start process can be initiated centrally by the administrator at the server. Unplugging and reconnecting the internal devices also initiates a restart. The Access door loudspeaker controller can be restarted by briefly disconnecting the relevant line recti-fier or by actuating the reset button.A restart of the internal devices is signalled by a yellow flashing light, starting with button 8 and ending with button 6, and the display lights up in white. If the start is successful and when the device has received all the information from the server, the system goes to the operating status. In the event of a fault, e.g. the internal device is not configured, all the buttons light up continuously in red.

Page 135: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

135

Initial commissioning/Login

Requirements:• PC with installed browser (Firefox, latest version)• The PC and Access Server must be in the same network/linked using a crossover cable• The Access Server commissioning instructions can be found in the Siedle download area.

Registration at the administrator user interface From Access server version 3.0.0, the login confirmation prompt on the login page is deactivated as standard. In order to reactivate the security code request, please follow the procedure described in the Access commissioning instructions (chapter Activating the security code request).

Login via a web interface takes place on the Access server. For this, enter the IP address of the server. This is defined as 192.168.1.1 in the as-delivered status.

The administrator set in the factory has the account name “admin” and the password “admin”. In addition, a randomly generated security code is required with each login. This is entered in the security code field. If the security code is not legible, click onto it to generate a new code. Start the login process using the “login” button. Further con-figuration is prompted by the server instructions and using the integrated help function.

Page 136: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

136

10 Servicing LED displays

ATLC 670-0

LED display LED operating status Functional characteristics

LED 1 off no operating voltage

lights up in green operating voltage applied

Link lights up in green connection to switch exists

flashes green data communication with the device

off no connection to the switch

Status lights up in green Vario bus ready for operation

flashes green data communication in the Vario bus

Error/OK lights up briefly in green after Power On for around 5 seconds

flashes green during ramp-up, flashing starts up appr. 20 seconds after Power On

lights up in green ATLC is logged in at the server

lights up in red error logging into server

A1 lights up in green output 1 HIGH (DR)

off output 1 LOW (DR)

A2 lights up in green output 2 HIGH

off output 2 HIGH

A3 lights up in green output 3 HIGH (LI)

off output 3 LOW

E lights up in green input 1 HIGH (LI)

off input 1 LOW

ATLC 670-0

SN 0000000000

IP 20

Access Türlautsprecher-ControllerAccess Door loudspeaker controllerAccess Contrôleur de platine de rue

Link

Status

Error / OK

A1 A2 A3 E

23 24 13 14 15 16 17 18 S1 S2 S3 S4 D1 D2 V1 V2

Output Input ATLM/ACM

LED 1

Reset

Page 137: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

137

AHTV/AHFV 670-…

LED display LED operating status Functional characteristics

LED 8 flashes yellow Searching for the server

off server found

LED 7 flashes yellow loading configuration from server

off export successfully completed

LED 6 flashes yellow login to server

off login successful

LED 1-8 lights up briefly in yellow after Power On for around 5 sec-onds

lights up in red error logging into server

off successfully logged into server

LED 1-8 Flashes for appr. 2 mins. Software update for terminals

ATLM 670-...

LED display LED operating status Functional characteristics

LED 1 flashes 3x in green Device starts up

off Ramp up successfully completed

lights up in green Audio active

Flashes briefly 3x in green unassigned/unprogrammed call button is actuated

LED 1

LED 4

LED 5

LED 8

LED 1

LED 8LED 1

Page 138: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

138

10 Servicing Terminal connections and measured values

ATLC 670-0

Terminal Description Measured values

V1V2

Video signal (two-wire FBAS) appr. 40 – 200 mV AConly with active video connection

S1S3

Microphone +Microphone -

appr. 42,1 – 47,4 V DC(Typical: 46,2 V DC)

S2S4

Loudspeaker +Loudspeaker -

appr. 42,1 – 47,4 V DC(Typical: 46,2 V DC)

D1D2

Variobus +Variobus -

appr. 230 – 270 mV DC(Typical: 250 mV  DC)

13/14 Output 2 potential-free -

15/16 Input 1 potential-free * -

17/18 Input 1 electrically isolated * -

23/24 Output 1 potential AC/DC programmable: appr. 10-16 V AC, 13 V DC

* The switching input can either be used potential-free or electrically isolated. It is not intended for simul-taneous use.

ANG 600-0

Terminal Description Measured values

11 Changeover contact A3 common -

12 Changeover contact A3 N.C. con-tact

-

14 Changeover contact A3 N.O. con-tact

-

+/– Output voltage 48 V DC, 800 mA appr. 48 V DC

Specification of the changeover contact:• Contact load at least 5 V, 100 mA 10 V, 10 mA 24 V, 1 mA• Admissible switching outputs: • Motor max. 3 A bulbs max. 1300 W• Energy saving lamps max. 18 x Silvania 7 W or 12 x Osram 11 W• Fluorescent lamps uncompensated cos j 0.5 max. 800 VA Duo fluores-cent lamps max. 1200 VA• Parallel compensated fluorescent lamps max. 400 VA• Iron core transformers for low-voltage halogen lamps max. 1000 W• Electronic transformers for low-voltage halogen lamps max. 1300 W

Page 139: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

139

AIVS 670-0

Terminal Description Measured values

V1V2

Video signal (two-wire FBAS) appr. 40 – 200 mV AConly with active video connection

V3V4

Supply AIVS 670-0 +Supply AIVS 670-0 -

appr. 48 V DC

V5V6

Camera actuation +Camera actuation -

appr. 48 V DC

S5S6S7

Camera supply permanent +Camera supply control signal +Camera supply -

appr. 12/24 V DC

* The total current from S5 - S7 and S6 - S7 is limited to 200 mA. The output voltage always corresponds to the set switch position.

Page 140: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

140

11 Glossary

3G (UMTS)Third generation mobile network standard with transfer rates of up to 42 Mbps if improved data transfer methods (HSDPA+) are used.-> UMTS, HSDPA(+)

4G (LTE-Advanced)Advanced 4th generation LTE mobile network standard (also called LTE Max). Currently transfer rates of up to 300 Mbps are offered. The maximum possible transfer rates may vary from country to country. According to the standard, transfer rates of up to 1000 Mbps are envis-aged.-> LTE-Advanced

Access controlSecurity system which controls the access to a property (plot, building, room, etc.) via a set of rules defined by the user (access for whom, when and where). Thus only authorised persons obtain (time-limited) access to the areas for which they have been approved. Siedle offers a modular access control system which can also be operated in parallel with Access via the Variobus.

BackupBackup copy/backed up data of a system on a separate storage medium for the purpose of data recovery if data is lost. System-dependent configuration and/or operating data can be recovered. There are different methods for cre-ating a backup.-> Data backup

BandwidthParameter of signal transmission systems in telecommunications (e.g. IP-based networks) which describes and classifies the theoretical data transmission performance. The bandwidth of the transmission path (e.g. network cable) determines the maximum theoretical data trans-mission rate which can be reliably transmitted per unit of time and is the difference between an upper and lower frequency value within a frequency range in which the data transmission takes place by means of signals.The greater the bandwidth, the more information can be trans-mitted per unit of time. Bandwidth is expressed as a frequency value in units of Hertz (Hz), if necessary with unit suffixes (M for Mega = mil-lions) (e.g. 300 MHz). Colloquially, bandwidth is also used as a synonym for the data transmission rate within IP-based networks, although nor-mally the transfer rate or data rate is meant.

Cat. 5 – Category 5Class (stage) of a standardised multi-stage classification system of TP cables (twisted pair data cable) for use in telecommunications and infor-mation technology. The classification system specifies the transfer property requirements of a data cable in the relevant class and thereby forms the basic for the specification (link class) of an end-to-end data transmis-sion path with all components. The requirements on a data cable increase with the suffix (digit). Cat. 5 contains data cable specifications for a data transfer path (data cable and junc-tion boxes) of up to 90 m and data transfer rates of over 20 Mbps or operating frequencies (bandwidth) of up to 100 MHz (Megahertz) and thereby for the 100 BASE-TX (2-pair) Ethernet application in IP-based networks.-> TP – Twisted Pair

Data backupCopying or exporting system confi-guration and/or operating data for creating a backup copy for the pur-pose of data recovery if data is lost.-.> Backup

Delay (information technology)-> Latency time

Page 141: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

141

DHCP – Dynamic Host Configuration ProtocolNetwork/communication protocol which enables the integration of any computers (clients) in an existing network based on a leading instance (server, router, etc.) without manu-ally configuring the network inter-face. Information needed for net-work traffic and data exchange, such as IP address, subnet mask, gateway, DNS and, where applicable, other settings, are automatically assigned, provided the operating system/its configuration of the computer (client) supports this.

DistributionThis is the place where several devices are switched together (con-nected). This often takes place in a distributor cabinet, although this is not mandatory. Large distribution panels can fill an entire room.

Door areaIn the door area are all devices connected to the system via an Access door loudspeaker controller ATLC 670-… This also includes cam-eras which monitor different areas.

DoormaticProgrammable function which actu-ates a contact in the ATLC 670-… with a time delay (door release).Example: The entrance doors to a doctor’s surgery can be opened directly after pressing the call button, as the door release is auto-matically triggered.

DNS – Domain Name SystemDirectory service (database) in larger networks and the Internet for con-verting domain names (e.g. www.siedle.com) into IP addresses (e.g. 10.11.12.13). DNS is automatically managed and continuously updated on the Internet by numerous decen-trally positioned servers. Without DNS, a company homepage on the Internet could only be called up by entering the IP address (if known).

DynDNS – dynamic DNS (DDNS)Service for automatically updating the associated domain entry (speci-fied domain name) in the DNS in real time after a (public) IP address is changed. In this way, a computer can always be reached under the same domain name, even if the user does not know the actual IP address. For example, a typical application is the accessibility of a computer via the Internet, which is operated on a private DSL connection with daily forced disconnection and a newly assigned IP address. DynDNS can be run as a service via various DynDNS providers.

FirewallSecurity system which can protect an individual computer, server or an entire network against unwanted network access, based on config-ured network communication rules. The firewall may be software on an end device or an independent device in the network.

FirmwareSoftware that can be embedded in electronic devices (e.g. indoor stations) and is needed for their fundamental operation. Firmware only works with its intended device. It is only possible for the end user to change the firmware themselves when the manufacturer provides a software package which is able to carry out the software replacement on the device.

G.711Standard (recommended) for codecs used for digital audio compression of analogue audio signals with the aid of pulse code modulation (PCM) for IP telephony (VoIP) and classic landline telephony (ISDN) applica-tions. The audio codec G.711 is lossless and requires very little pro-cessing power.

Page 142: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

142

11 Glossary

GatewayNetwork-capable components (cou-pling element) which connects or disconnects networks which can be based on completely different archi-tectures and protocols.Example: KNX (bus system) is con-nected to the Access system (TCP/IP network) via a KNX gateway. In the Access system, gateways for KNX and an external connection to SIP telephony (SIP gateway and SIP provider) can be created.

H.264/MPEG-4 AVCRecommended and functionally-extensive standard for video com-pression of digitalised and high-reso-lution video sequences (e.g. HDTV).

HSDPA(+) – High Speed Downlink Packet AccessData transfer method of the 3G mobile network standard (UMTS) with standard transmission rates of up to 7.2 Mbps (HSDPA) or 42 Mbps (HSDPA+) (also called 3.5G, 3G+ or UMTS broadband). The maximum possible transfer rates may vary from country to country. According to HSDPA end device categories, transfer rates of up to 337.5 Mbps are possible.

HTTP – Hypertext Transfer ProtocolProtocol for data/file transfer of text, image, audio or video files within an IP-based network or via the Internet. The http protocol is used to transmit single frames of the MJPEG video sequence from IP cameras, for example.-> IP camera, MJPEG

Indoor stationCall station and accessory for use indoors as duplex call station for the door area (door station) outdoors. All hardware-based Access call sta-tions for indoors (AHT/V, AHF/V, AVP) are regarded as indoor stations. However, computers or smartphones which can provide a similar range of functions through the use of the rel-evant client software or app are not included in this definition.

IP cameraNetwork (video) camera which provides a retrievable video image in the digital form of a video stream via the IP protocol in an IP-based network or Internet. IP cameras can be remotely configured via network access and offer a user-dependent extended range of functions as well as security functions for convenient video surveillance. The network bandwidth required to transmit the video stream depends on the camera’s single frame resolution and frame rate as well as the video com-pression method used. To access the video stream, the relevant URL of the IP camera must be known. An URL contains the information with which the video stream of an IP camera can be reached in the network and gen-erally contains an IP address or host name, as well as further-reaching information about the video stream.

Page 143: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

143

KNX standard – Konnex standardGlobally accepted bus standard (bus system) for building automa-tion, where the device control (KNX bus system) and the power supply (230 V AC) are operated separately from one another in two networks. Both networks can be installed inde-pendent from one another or in par-allel in the building. The individual components are controlled via the control network (KNW bus system) by means of a telegram which con-tains the relevant control commands. KNX is sold by various providers as a building automation solution.

LAN – Local Area NetworkLocal Area Network Network which connects the system components.The term LAN is used to make a rela-tive classification/distinction between wired, non-public (private) and/or locally-operated, networks and other networks.-> WAN, WLAN

Latency time (delay time)Technically-limited time difference (delayed response time) of technical devices in an IP-based network (Internet) between the initiated query and the response (answer) received by the remote station awaiting response. The following requirements apply to the Access system:• Maximum 50 ms delay in one direction (one-way delay)• Maximum 100 ms overall delay• Packet loss < 1%• Maximum 20 ms jitter (variation)In IP-based networks, an excessive latency time can result in a notice-able service delay and malfunctions through to non-availability of indi-vidual or several devices/systems.

LicencesActivated usage right on the Access server, the scope of functions of which is provided by the relevant licence. An Access basic licence is required for standard operation of the Access server (included in the scope of supply of the hardware versions, optional with the soft-ware versions). The relevant device licences are included in the scope of supply for operation of the Access indoor stations. Additional perfor-mance features are activated via optional licences. For details see the Access licences chapter (For detailed information, see page 40).

LTE Advanced – Long Term Evolution AdvancedAdvanced 4th generation LTE mobile network standard (also called LTE Max). According to the standard, transfer rates of up to 1000 Mbps are envisaged. Currently transfer rates of up to 300 Mbps are offered. LTE is being continually expanded in Germany. The maximum possible transfer rates depend on method and expansion and may vary from country to country.-> 4G (LTE-Advanced)

Page 144: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

144

11 Glossary

MAC address – Media Access Control addressTwelve-character hexadecimal hard-ware address organised in pairs (e.g. 1A-2B-3C-4E-5F-66) of an internal or external network adapter/network-capable device interface (computer, router, etc.) for wireless and/or wired network connection (also called Ethernet address, Ethernet ID, air-port ID or Wi-Fi address). The MAC address can be used as a basis for automatic configuration of devices connected to an IP-based network and is used by various network proto-cols (e.g. DHCP). In theory, the MAC address of a network-capable device should be globally unique and it was regarded as a unique identifier within a network. The preset MAC address of a network adapter itself cannot be changed. However, the MAC addresses to be communicated can be changed as desired by software or created at random using existing device functions (e.g. smartphones) in order to prevent unique identifica-tion or to use replacement devices with the same ID. The MAC address also contains the manufacturer code as a six-character prefix.

MJPEG – Motion JPEGProcess (video codec) for single frame compression of a video sequence to be transmitted, which is used on network cameras. MJPEG is a process used to compress the content of the single frames. The video stream is transmitted in JPEG-compressed single frames via the HTTP protocol.

MulticastAn information and communica-tion technology type of point-to-multipoint connection for efficiently sending data via a multicast IP address. Information is sent from the source just once, duplicated in the IP-based network and automatically forwarded to all the pre-determined recipients. This relieves the load on the sending network components (e.g. server) as the duplication and distribution of the sent informa-tion takes place via the distribution components (e.g. multicast-capable switches). All distribution compo-nents within a network must be multicast-capable. Access is multi-cast-capable.-> Unicast

NAT – Network Address TranslationNetwork address translation method for automatic replacement of address information in data packets with other information, to connect various networks (e.g. private and public IP-based network). For each established connection, the request-er’s connection information and the destination are stored so that the answer can be assigned to the right requester. In the public IP-based net-work, the private network address of the requester is not known. NAT is required in iPv4 networks due to the existing shortage of iPv4 addresses. Private networks receive just one public network address instead of several. There are two different NAT methods. NAT is also used within an IP-based network for the internal separation or connection of several private networks with different net-work address spaces.

Page 145: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

145

NTP – Network Time ProtocolSynchronisation protocol which syn-chronises the time within IP-based networks and the Internet. NTP is realised via decentral and synchro-nised time servers which are located on the Internet. Without a central time server, time differences could arise between devices in IP-based networks. Significant time differ-ences can lead to malfunctions within IP-based networks.

Operating manualCurrent Access system documenta-tion including all changes to hard-ware and software components. In addition, responsible contact partners, regular measures for safe-guarding operation and instructions for emergencies can be documented (logbook).

PoE – Power over EthernetPower over Ethernet supplies an indoor station or another PoE-capable device via the connected network cable. Network-capable devices can be decentrally and indi-vidually supplied with PoE injectors or centrally supplied via PoE-capable distribution components (e.g. switches). PoE is divided into various power classes. PoE is standardised according to IEEE 802.3… and is continually developed and improved.

QoS – Quality of ServiceProcess for determining the transfer behaviour of selected services in net-works. With QoS, different network protocols are parametrised in order to influence factors such as band-width and transport priority of a net-work protocol to ensure the required network behaviour. For example, QoS provides high transport priority and bandwidth for the telephony in an IP-based network in order to ensure that it works correctly.

RouterNetwork components which connect two or more IP-based networks with, if necessary, different network proto-cols and/or network address spaces and enable data traffic between these networks or even the Internet. A router can also be used within an IP-based network for the internal separation or connection of several private networks with different net-work address spaces. Routers come in a variety of designs with different equipment versions relating to the range of functions and the security functions.-> NAT

RTP – Real-Time Transport ProtocolProtocol for continuous and packet-based transmission of real-time sensitive multimedia data streams (audio, video, text, etc.) in IP-based networks. RTP is used with SIP to transport the audio and video streams of the call and is normally operated via the UDP protocol.-> SIP, UDP

SIP – Session Initiation ProtocolNetwork protocol for standardised control and implementation of a communication connection (session) between at least two location-independent users in IP-based net-works. SIP is used as a protocol in the Access system and IP telephony (VoIP). SIP is internationally accepted.-> VoIP, SIP Client

SIP ClientHardware or software-based applica-tion which uses the SIP standard for location-independent communica-tion with other SIP-capable applica-tions within IP-based networks. SIP clients include SIP telephones (VoIP) or VoIP apps on mobile phones, for example.

Page 146: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

146

11 Glossary

SIP-GatewaySoftware-based SIP interface of the Access server for connecting a SIP-capable telephone system with one or more (bundled) speech channels (SIP trunk) to the Access server via an IP-based network. SIP gateways enable connection of the Siedle Access server on the network side to a SIP-capable telephone system provided by the customer via a SIP trunk. The Access-side configuration takes place via the administration interface of the Access server. The trunk connection is established using the static IP address of the telephone system and the Access server and without SIP account login data.-> SIP Trunk

SIP-ProviderSoftware-based SIP interface of the Access server for connecting a SIP provider account to the Access server via an IP-based network. The Access-side configuration takes place via the administration interface of the Access server. SIP provider accounts link the Access server over the Internet to the VoIP telephony connection of a VoIP provider by means of the Session Initiation Protocol (SIP). Log on as SIP user at a SIP provider with 1 speech channel (TC system, Cloud, …). In addition, you are given a central overview for configuration of the SIP provider account.-> SIP user, SIP Client

SIP TrunkTechnique (method) with which the Access server can be connected to an IP-based telephone system via an access point. Via this trunk connec-tion, (several) bundled call numbers can be used from the Access server for telephony purposes through the IP-based telephone network. The telephony connection of several call numbers with one access point takes place on the Access server via the SIP gateway. To connect a SIP-capable telephone system to the Access server, the trunk connection is estab-lished based on the static IP address of the telephone system and the Access server and entirely without SIP account login data.-> SIP-Gateway

Page 147: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

147

SIP User (SIP account)User account which has been cre-ated with a VoIP provider and contains the required access and operating data of a VoIP telephony connection of a VoIP telephone con-nection and is linked to an associ-ated call number. The login data of the user account can be created in the Access server as SIP provider in order to log the Access server onto the VoIP telephony connection of a VoIP provider by means of the session initiation protocol (SIP) via the Internet, and thereby be able to make telephone calls.-> SIP Client, SIP-Provider

Storey call buttonThe storey call button (ERT) is used to call from a storey door to the indoor device. This can be connected as standard on all Access indoor stations via the right-hand R45 jack (switching input E1 – terminal 3,6) of the indoor station and addition-ally configured via the administration interface of the Access system.

SwitchCentral coupling element and distri-bution component which links indi-vidual network components to an IP-based network and is responsible for forwarding data traffic within the IP-based network (also called a net-work switch or distributor). Switches come in a variety of hardware-based designs with different equipment versions relating to the range of functions and the security functions.

TCP – Transmission Control net-work ProtocolTransport protocol for data traffic between network-capable devices (servers, computers, etc.) in IP-based networks. TCP is used for packet-based data transfer in almost all operating systems and is part of the IP protocol for the Internet. For bidi-rectional data traffic, there must be a connection between the devices.TCP includes:• Transport service• End-to-end control (reliable data transfer)• Connection management• Data flow and time control• Multiplexing connections• Error handling

Telecom socket RJ45 8/8Standardised connection unit for network cabling with two eight-pin RJ45 jacks for correct connection of Access indoor stations.The left-hand jack is used for the LAN network. The storey call button and if applicable the customer’s own existing signalling device are con-nected using the right-hand jack.

TP – Twisted PairA TP cable (TP) is a symmetrical copper cable used for data transfer, which consists of two cores (1 core pair) which are twisted around one another. In IP-based networks, cables with four core pairs are normally used. The data transfer takes place in a single direction per core pair. For a data connection 2 core pairs are required (sending and receiving). In the case of higher data transfer standards (e.g. 1000 BASE-T Ethernet) all 4 core pairs are used (2x sending and 2x receiving). TP cables come in various unshielded and shielded designs, each with different core diameters. The performance capability of a TP cable is specified by its category (e.g. Cat 5).-> Cat. 5

Page 148: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

148

11 Glossary

UDP – User Datagram ProtocolTransport protocol for data traffic between network-capable devices (servers, computers, etc.) in IP-based networks. Data transmission used in almost all operating systems and is part of the IP protocol for the Internet. For data traffic, a connec-tion is not necessary between the devices. UDP is a limited-reliability, insecure and unprotected transfer protocol, as no mechanisms are provided for this. In return, UDP uses less transport management data (overhead), thereby creating a lower additional data volume and is char-acterised by a lower latency time. In contrast to TCP, UDP has a reduced range of functions:• Transport service• Multiplexing connections• Error handling• UDP is used in voice transmission, as a low latency time is required.

UMTS – Universal Mobile Telecommunications System-> 3G (UMTS)

UnicastAn information and communication technology type of point-to-point connection for sending data from a sender to a recipient via an IP address. Information is sent from the source to the pre-defined recipient on an individual basis. Standard switches can be used for this type of data transmission. Existing networks without multicast ability do not have to be upgraded. Access is unicast-capable.-> Multicast

VLAN – Virtual Local Area NetworkClosed subnetwork within IP-based networks. A VLAN separates physical IP-based networks into any number of subnetworks. VLAN-capable switches ensure that data packets are only sent within this VLAN and are not forwarded to another VLAN, even though different VLANs can be connected to a shared switch or via several switches. Different methods are available for setting up a VLAN:• Port-based (old method)• Static (old method)• Tagged• Dynamic

VoIP – Voice over IPNetwork protocol for voice, data and video transmission which is used for IP/internet telephony and enables telephony in IP-based stationary and mobile networks. SIP, RTP and UDP are used for VoIP, to name a few. VoIP can only be used with suitable end devices, adapters or software clients. In addition, internal or external VoIP provision (e.g. VoIP provider) is required. Access provides an optional internal VoIP provision.

WAN – Wide Area NetworkWide area network which is designed for voice and/or data transfer over large distances. A WAN (e.g. Internet) covers a large distance and can be used without restrictions for business and private communica-tion. The term WAN serves to make a distinction between the relevant network sizes. The term WAN is used to make a relative classification/distinction between cross region and/or public IP-based networks and other networks.-> LAN, WLAN

Page 149: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

149

WLAN – Wireless LANWireless local network based on radio, for communication and data transfer between network-capable devices (computer, smartphone, etc.) and, if necessary, the Internet. The data transfer rate is continually being improved with the standard IEEE 802.11…. (Gross) data rates of up to 6.9 Gbps are currently possible (IEEE 802.11ac).The term WLAN is used to make a relative classification/distinc-tion between wireless, non-public (private) and/or locally-operated, IP-based networks and other net-works.-> LAN, WAN, Wi-Fi

Wi-Fi – Wireless FidelityCertification for WLAN products based on IEEE standards for ensuring interoperability/compatibility of the various WLAN products from dif-ferent manufacturers. Wi-Fi-certified products therefore comply with the WLAN standard IEEE 802.11… This is why Wi-Fi is incorrectly used as a synonym for a wireless network (WLAN). Wi-Fi is represented by the Wi-Fi-Alliance which includes all renowned manufacturers of network-capable devices.

Page 150: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

150

12 Index Access components

Designation Summarized description

ACM 670/673/678-… Camera module 24

AGW 670-… Gateway – network separation 38

AHT/AHF 870-… Indoor station 27

AHTV/AHFV 870-… Indoor station 26, 27

AIVS 670-… Video interface (coupler) 23

ALFA 270-… Access application licence 42

ALFS/ALFT 270-… Access application licence 42

ALFV 270-… Access application licence 42

ALKNX 270-… Access application licence 42

ALT 270-… Access application licence 42

ANG 600-… Line rectifier 29, 31

APR 670-0 10/20/40/80/160/320 Access user licence packages 41

ASC/ASHT 170-… Client software/access licence 38

ASM 170-… Software module/access licence 39

ASH 670-04 S/M Access server hardware 34

ATLC/NG 670-… Door controller 29

ASU 670-… Access server upgrade (HW) 39

ATLCE 670-… Door controller extension 30

ATLE/ATLM 670-… Function module for door station 21

AUV 870-… Indoor station upgrade 28

AVA 670-… Video interface (decoupler) 30

AVP 870-… Indoor station 26

AZA/AZIO 870-… Indoor station accessory 28

AZTV/AZTVP 870-… Indoor station accessory 28

BRMA 050-… Call button connection module 21

BTM 650-… Function module for door station 22

CE 600/950-… External camera 25

COM 611-… Function module for door station 22, 63

DRM 612-… Function module for door station 22

DSC 602-… Pilfer safeguard controller 30

EC 602-… Access control controller 65

ECE 602-… Access control controller extension 65

ELM 611-… Function module for door station 63

FPM 611-… Function module for door station 63

NG 602-… Line rectifier 31

PME-… Mail notification system 23

Siedle app for Access… App (iPhone/iPad) 39

TCIP SRV 603-… Access control IP server 64

TCIP 603-… Access control IP controller 32

TR 602/603-… Transformer 32

TÖ 61x-… Door release 23

VNG 602-… Line rectifier 31

VTMC 640-… Camera module 25

ZRE 600-… Server mounting accessories 28, 65

ZWA 640-… Connection accessories 30

Page 151: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

151

Access topics

Access cameras 24

Access Certified Partners 153

Access circuit diagrams 66

Access control 60

Access control connected values 60

Access control controller 64

Access custom-fit door loud-speaker circuit diagrams 98

Access licences 40

Access server variants 34

Access system functions 44

Accessory 28

After-sales service 153

App 39

Architect and project service 153

Button configuration 49, 53

Cabling for indoor devices 11

Cabling in the door area 8

Cabling structure/areas 10

CAL (Microsoft licences) 40, 43

Camera connection circuit diagrams 126

Cameras 24

Circuit diagrams – overview 66

Client-Software 38

Commissioning 132

Commissioning functions 46

Commissioning instruction 132

Commissioning requirements 132

Configuration – Access System 48

Control functions (switching/control) 45

Customer support and cus-tomer advice/Siedle centres 153

Distribution components 29, 64

Door area 8

Door controller 29

Door stations (outdoor/indoor area) 20

Doormatic 50

Electrical distribution board and IT cabinet systems 4

Electrical voltage 4

Electrostatic charging 4

Exchanging devices 134

Extension of the switching outputs/inputs 50

External cameras 25

External device licences 42

Function overview 44

General planning information 8

Glossary 140

Hardware clients 47

Index for Access components 150

Indoor stations 26

Initial commissioning/Login 135

Interfaces 46

LED displays 136

LED operating status 137

Legal notice 5

Licences 40

Line rectifiers 31

Location of the video camera 13

Maintenance contract 133

Microsoft licences (CAL) 40, 43

Minimum requirements – Server hardware / Virtual machine 36

Modules – access control 62

Network characteristics – Access system 10

Network LAN 10

Network security 38

Optional Access licences 42

Performance features – Access 6

Permitted conductor material 9

Pick-up range of the camera 13

Power over Ethernet (PoE) 10

Protect your network! 5

Protect your property! 5

Registration at the administrator user interface 135

Safety remarks 4

Server access control 64

Server administration – device parameters 51

Service functions 46

Service requirement 134

Servicing 134

Siedle centres 153

Siedle Classic 20

Siedle Classic circuit diagrams 104

Siedle service 153

Siedle Steel 20

Siedle Steel circuit diagrams 114

Siedle Vario 20

Siedle Vario circuit diagrams 70

Software integration for non-Siedle systems 39

Space requirements in distribu-tion boards/IT cabinets 33

Specification – switching outputs / inputs 68

Start process 134

Storey call button circuit diagrams 130

Supplementary functions 11, 44

Supply limits ATLC/NG 670-… 9, 12

Switching outputs/inputs 49, 56, 68

System components 18

System description 6

System extension 30

System overview 7

System structure, conductor material and range 8

System update 4

Telephony functions 45

Terminal assignment RJ45 131

Terminal connections and measured values 138

Transformers 32, 62

Updates and maintenance 133

Upgrade (indoor station) 28

Upgrade (server) 39

Video functions 45

Virtualization 37

Warranty 134

Page 152: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

152

13 Siedle service Customer support and customer advice/Siedle centres

Welcome to Siedle!Also in your area.Qualified staff are on hand to offer a fast, competent service.By telephone, or where necessary we will be pleased to visit you on site.Customers outside of Germany can contact one of our international rep-resentatives.

The current overview broken down according to regions is located in the download area on www.siedle.com

Page 153: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

153

After-sales service

Services and information Siedle websitewww.siedle.com

Access Certified Partner near to you

www.siedle.en/acp

Page 154: Planning and System Manual Access Professional - … and System Manual Access Professional Issue 2017. 2 ... 9 Commissioning and operation ... iPad iPad iPhone Router Internet ASHT

S. Siedle & SöhneTelefon- und Telegrafenwerke OHG

Postfach 115578113 FurtwangenBregstraße 178120 Furtwangen

Telefon +49 7723 63-0Telefax +49 7723 [email protected]