pl2011 fad eu euro
TRANSCRIPT
valid from 31 JANUARY 2011
2011 Devices Price List€
Firelock Devices
Series 751 Firelock® Alarm Check Valve UL/FM
Series 751 Firelock Alarm Check Valve CE/Vds/LPCB
Series 759 Wet Alarm Check Valve
Series 764 Firelock NXT™ Alternate (Wet/Dry) Valve
Series 768 Firelock NXT Dry Valve
Series 769 Firelock NXT Deluge Valve
Series 769 Firelock NXT Deluge Valve Trim Kits
Series 769 Firelock NXT Preaction Valve
Accessories
Device Replacement Parts
Trim Optional Parts
Trim Replacement Parts
Electrical Accessories
Submitted By: __________________________________ Date: __________________________________
Approved By: ___________________________________ Date: __________________________________
1
Index
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Table of contents
FIRELocK® automatIc DEvIcES anD accESSoRIESSeries 751 FireLock Alarm Check Valve . . . . . . . . . . . . . . . . . . . . . . . . 4Series 764 FireLock NXT Alternate (Wet/Dry) Valve . . . . . . . . . . . . . . . 7Series 768 FireLock NXT Dry Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Series 769 FireLock NXT Deluge Valve . . . . . . . . . . . . . . . . . . . . . . . 12Series 769 FireLock NXT Preaction Valve . . . . . . . . . . . . . . . . . . . . . 19accESSoRIESDevice Replacement Parts
Series 751, 756, 758 Clapper Seal Kit with Cover Gasket . . . . . . . . . . . . . . . . . . . . . . . . . 26
Series 751 Clapper and Seal Kit Assembly (114, 165, and 168mm) . . . . . . . . . . . . . . . . . . . . 26
Series 751 Clapper and Seal Kit Assembly (all sizes except 114, 165, 168, and 89 mm CE) . . 26
Series 751 Cover Bolts . . . . . . . . . . . . . . . . . . . . . . . . . 26Series 751 Clapper Spring . . . . . . . . . . . . . . . . . . . . . . 26Series 751 Spacer . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Series 751 Clapper Shaft – FM . . . . . . . . . . . . . . . . . . 26Series 751 Clapper Shaft – CE . . . . . . . . . . . . . . . . . . . 26Series 751 Clapper Shaft O-Ring – CE . . . . . . . . . . . . . 27Series 768/769 Diaphragm . . . . . . . . . . . . . . . . . . . . . 27Re-Build Kits for Series 756/758 and
FireLock NXT Valves . . . . . . . . . . . . . . . . . . . . . . . 27trim optional Parts
Series 751 Drain Connection Kit – FM . . . . . . . . . . . . . 27Series 751 Drain Connection Kit – CE . . . . . . . . . . . . . 27Series 768/769 FireLock NXT
Deluge/Preaction Systems Drain Connection Kit . . 27Series 752 Retard Chamber – FM . . . . . . . . . . . . . . . . 28Series 752 Retard Chamber – CE . . . . . . . . . . . . . . . . . 28Series 752V Retard Vent Kit . . . . . . . . . . . . . . . . . . . . . 28Series 746-LPA Dry Accelerator . . . . . . . . . . . . . . . . . . 28Series 760 Water Motor Alarm – UL, FM, CE, VdS . . . . 28Series 757 Air Maintenance Trim Assembly for
Series 768/769 . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Series 757P Air Maintenance Trim Assembly for
Series 768/769 with Pressure Switch . . . . . . . . . . 28Series 75D Water Column (Component Drain) Kit . . . . . 29Series 755 Manual Pull Station . . . . . . . . . . . . . . . . . . 29
trim Replacement Parts90° Drain Valve – FM . . . . . . . . . . . . . . . . . . . . . . . . . . 2990° Drain Test Valve – CE . . . . . . . . . . . . . . . . . . . . . . 2990° Angle Valve for Series 768/769
FireLock NXT Valves . . . . . . . . . . . . . . . . . . . . . . . 29Series 722 Trim Ball Valve . . . . . . . . . . . . . . . . . . . . . . 30Gauge Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Series 748 Ball Check Valve . . . . . . . . . . . . . . . . . . . . . 30
Wye Strainer (Air/Water) . . . . . . . . . . . . . . . . . . . . . . . . 30Series 729 Ball Drip Assembly – FM . . . . . . . . . . . . . . 30Series 749 Ball Drip Assembly – CE . . . . . . . . . . . . . . . 30Pressure Gauge Air/Water . . . . . . . . . . . . . . . . . . . . . . 30Restrictors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Swing Check Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Drip Cup Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Series 749 Auto Drain Assembly . . . . . . . . . . . . . . . . . 31Male Straight Piece for
Series 749 Auto Drain Assembly . . . . . . . . . . . . . . 31In-Line Spring Loaded Ball Check Valve for
Series 757 Air Maintenance Trim . . . . . . . . . . . . . 313-in-1 Strainer/Check/Restrictor Assembly . . . . . . . . . . 31Airline Manifold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Series 776 Low Pressure Actuator . . . . . . . . . . . . . . . . 32Replacement Kit for Series 776
Low Pressure Actuator . . . . . . . . . . . . . . . . . . . . . 32Auto Vent Assembly for 776 Actuator . . . . . . . . . . . . . . 32Series 798 Double Pneumatic Actuator . . . . . . . . . . . . 32Series 753E Solenoid Actuator . . . . . . . . . . . . . . . . . . . 32Replacement Coil Kit for
Series 753E Solenoid Actuator . . . . . . . . . . . . . . . 32Air Regulator for Series 757 Air Maintenance Trim . . . . 32Repair Kit for Series 746 Dry Accelerator . . . . . . . . . . . 32
Electrical accessoriesPressure Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Alarm Release Panels . . . . . . . . . . . . . . . . . . . . . . . . . 33Electric Pull Station . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Tamper Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Alarm Bells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Terms and Conditions of Sale . . . . . . . . . . Inside Back CoverWarranty . . . . . . . . . . . . . . . . . . . . . . . . . . Inside Back Cover
2
table of contents
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
FireLock® Automatic Devices and Accessories
FireLock automatic Devices and accessories
3www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Series 751, FireLock® Alarm Check Valve
Fire Protection Valves and Devices
Series 751
FIRELocK® aLaRm cHEcK vaLvERequest publication 30.01
VNIIPO
SERIES 751 aLaRm cHEcK vaLvE – uL/Fm
Valve Size Bare Valve Weight Price Each
[mm] [kg] Valve Pre-Trimmed
Groove by Groove
48,3 6,4 €1855,31
60,3 6,4 1855,31
73,0 15,6 1986,27
76,1 15,6 1986,27
88,9 16,0 1986,27
114,3 22,2 2180,37
165,1 31,3 2520,03
168,3 31,3 2520,03
219,1 64,4 3503,39
NOTE: All devices are non-returnable and non-cancellable.
For trim diagrams, see following page(s).
Order optional accessories as separate items.
Series 751, Alarm Check Valve Station
Series 751
FIRELocK aLaRm cHEcK vaLvE StatIonRequest publication 30.01
SERIES 751 aLaRm cHEcK vaLvE StatIon
Valve Size Bare Valve Weight Price Each
[mm] [kg] Valve Pre-Trimmed
DN80 24,0 €2666,85
DN100 54,0 2909,00
DN150 69,0 3459,02
DN200 83,0 4809,01
NOTE: All devices are non-returnable and non-cancellable.
For trim diagrams, see following page(s).
Order optional accessories as separate items.
4
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Exploded View Drawing – Trim ComponentsSERIES 751 FIRELocK aLaRm cHEcK vaLvE – vERtIcaL tRIm DIagRam (REtaRD cHambER oPtIonaL)
Grooved x Grooved
Optional Series 752VRetard Vent Kit
To Water MotorAlarm or Optional
Series 752V RetardVent Kit
Pipe toOpen Drain
Optional Locationfor Item 13
To Drain
To Drain
9
10
7
6
13
12
8
2
3
1
5
14
4
From WaterSupply
ToSystem
11
15
15
Bill of Materials 1 Series 751 FireLock Alarm Check Valve 2 Water Supply Pressure Gauge (0-300 psi/0-2068 kPa) 3 Swing Check Valve 4 System Pressure Gauge (0-300 psi/0-2068 kPa) 5 Alarm Line Ball Valve (Normally Open) 6 Alarm Test Line Ball Valve (Normally Closed) 7 Alarm Line Drain Restrictor (1/16-inch) 8 System Main Drain Valve 9 Series 752 Retard Chamber Assembly (Optional/Sold Separately) 10 Series 760 Water Motor Alarm (Optional/Sold Separately) 11 Water Supply Main Control Valve (Optional/Sold Separately – Comes Standard when VQR Assembly is Ordered) 12 FireLock Rigid Coupling (Optional/Sold Separately – Comes Standard when VQR Assembly is Ordered) 13 Alarm Pressure Switch (Optional/Sold Separately) 14 Series 752V Retard Vent Kit (Optional/Sold Separately) *15 Gauge Valve
5
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Exploded View Drawing – Trim ComponentsSERIES 751 FIRELocK aLaRm cHEcK vaLvE – vERtIcaL tRIm DIagRam cE/vDS/LPcb (REtaRD cHambER oPtIonaL)
Grooved x Grooved
Optional Series 752VRetard Vent Kit
To Water MotorAlarm or Optional
Series 752V RetardVent Kit
Pipe toOpen Drain
10
9
15
12
From WaterSupply
ToSystem
ToDrain
ToDrain
3
2
5
14
4
4
1
11
7
8
Normally Open
(Lockable)
6
13
Bill of Materials 1 Series 751 FireLock European Alarm Check Valve 2 FireLock Rigid Coupling 3 Water Supply Main Control Valve 4 Gauge Valve 5 Water Supply Pressure Gauge (0-25 Bar) 6 Drain Swing Check Valve 7 Restricted Orifice/Alarm Line Drain 8 System Main Drain Valve 9 Series 752 VdS Retarding Chamber Assembly (Optional/Sold Separately)10 Alarm Pressure Switch11 Alarm Line Ball Valve (Lockable - Normally Open)12 Series 760 European Water Motor Alarm Assembly (Optional/Sold Separately)13 System Test Valve14 System Pressure Gauge (0-25 Bar)15 Series 752V Retard Vent Kit * (Optional/Sold Separately)
* The Series 752V Retard Vent Kit is required any time an air break is needed above the Series 752 VdS Retarding Chamber Assembly. In addition, the Series 752V Retard Vent Kit is required if multiple valves are tied into one water motor alarm and a check valve isolates each line.
6
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Series 764, FireLock NXT Alternate (Wet/Dry) Valve
Series 764
FIRELocK nXt® aLtERnatE (wEt/DRy) vaLvERequest publication 30.83
FIRELocK SERIES 764 aLtERnatE (wEt/DRy) vaLvE
Valve Size Bare Valve WeightVic-Quick Riser
Pre-Trimmed with 776-LPA
[mm] [kg] Price Each
Groove by Groove
48,3 7,5 €6853,91
60,3 7,7 6853,91
73,0 18,7 7534,16
76,1 18,7 7534,16
88,9 18,7 7534,16
114,3 26,7 7918,99
165,1 36,2 9098,36
168,3 36,2 9098,36
219,1 55,3 12808,15
NOTE: All devices are non-returnable and non-cancellable.
For trim diagrams, see following page(s).
Order optional accessories as separate items.
7
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Exploded View Drawing – Trim ComponentsSERIES 764 FIRELocK nXt aLtERnatE vaLvE (oPtIonaL accESSoRIES aLSo SHown)
5
4
BLocation
2
3
From WaterSupply
ToSystem
From SystemAir Feed
Open – DryClosed – Wet
Remove trim from this point up wheninstalling the optional dry accelerator.
The air gauge (Item 18) must remain in place.Add a tee to the accelerator to
re-position the air gauge
Remove this plug when utilizing a
supervisory switch
15
24
9
26
8
2313
14
16
6
2930
22
20
22
12
10
27
11
17
22
7
1
Alarm Test Valve(Normally Closed)
Closed – DryOpen – Wet
Closed – DryOpen – Wet
Remove this plugwhen utilizing a
supervisory switch
Open – DryClosed – Wet
28
21
When field installation ofa “manual pull station” is
performed, remove this plugand install necessary fittings.
Open – DryClosed – Wet
25
B
To Drip CupLocation
B
To Drip CupLocation
BTo Drip CupLocation
BTo Drip CupLocation
19
18
14a
14b
Bill of Materials 1 Series 764 FireLock NXT Alternate Wet/Dry Valve 2 FireLock Rigid Coupling 3 Water Supply Main Control Valve 4 Drain Swing Check Valve 5 Drip Cup with Cap 6 Alarm Pressure Switch 7 Series 729 Drip Check Valve 8 Diaphragm-Charge-Line Ball Valve (Lockable – Open/Dry, Closed/Wet) 9 3-in-1 Strainer/Check/Restrictor Assembly 10 Series 760 Water Motor Alarm (Optional/Sold Separately) 11 Alarm Test Ball Valve 12 Diaphragm-Charge-Line Pressure Gauge (0 – 300 psi/0 – 2068 kPa/0 – 20.7 Bar) 13 Series 749 Auto Drain 14 Series 746-LPA Dry Accelerator Assembly (Optional/Sold Separately) 15 Series 776 Low-Pressure Actuator 16 Air Manifold 17 Air Supervisory Pressure Switch 18 Dry System Air Pressure Gauge (0 – 80 psi/0 – 552 kPa/0 – 5.5 Bar with Retard) 19 Water Supply Main Drain Valve - Flow Test 20 Water Supply Pressure Gauge (0 – 300 psi/0 – 2068 kPa/0 – 20.7 Bar) 21 Drain Connection Kit 22 Gauge Valve 23 System Main Drain Valve 24 Series 748 Ball Check Valve 25 Dry System Air Supply Ball Valve (Lockable – Open/Dry, Closed/Wet) 26 Wet System Bypass Ball Valve (Lockable – Closed/Dry, Open/Wet) 27 Dry Check Isolation Ball Valve (Lockable – Open/Dry, Closed/Wet) 28 Alarm Line Drain Ball Valve (Lockable – Closed/Dry, Open/Wet) 29 Series 755 Manual Pull Station (Optional/ Sold Separately)30 Wet System Pressure Gauge (0 – 300 psi/0 – 2068 kPa/0 – 20.7 Bar)
Note 1
8
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Series 768, FireLock NXT Dry Valve
Series 768
FIRELocK nXt DRy vaLvERequest publication 30.80
VNIIPO
Valve SizeBare Valve
WeightVic-Quick Riser
Pre-Trimmed with 776-LPA
[mm] [kg] Price Each
Groove by Groove
48,3 7,5 €5298,53
60,3 7,7 5876,32
73,0 18,7 6478,73
76,1 18,7 6478,73
88,9 18,7 6234,66
114,3 26,7 6599,15
165,1 36,2 7581,97
168,3 36,2 7581,97
219,1 55,3 10673,47
NOTE: All devices are non-returnable and non-cancellable.
Some assembly required - instructions included.
For trim diagrams, see following page(s).
Order optional accessories as separate items.
9
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Exploded View Drawing – Trim ComponentsSERIES 768 FIRELocK nXt DRy vaLvE (oPtIonaL accESSoRIES aLSo SHown)
From WaterSupply
ToSystem
From SystemAir Feed
24
15
9
8
23
2
14
16
6
10
17
1318
22
1920
22
12
7
11
1
22
3
4
5
21
ALocation
A
To Drip CupLocation A
To Drip CupLocation
A
To Drip CupLocation
Bill of Materials 1 Series 768 FireLock NXT Dry Valve 2 FireLock Rigid Coupling 3 Water Supply Main Control Valve 4 Drain Swing Check Valve 5 Drip Cup with Cap 6 Alarm Pressure Switch 7 Series 729 Drip Check Valve 8 Diaphragm-Charge-Line Ball Valve (Normally Open) 9 3-in-1 Strainer/Check/Restrictor Assembly 10 Series 760 Water Motor Alarm (Optional/Sold Separately) 11 Alarm Test Ball Valve 12 Diaphragm-Charge-Line Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar) 13 Series 749 Auto Drain 14 Series 746-LPA Dry Accelerator Assembly (Optional/Sold Separately) 15 Series 776 Low-Pressure Actuator 16 Air Manifold 17 Air Supervisory Pressure Switch 18 System Pressure Gauge (0-80 psi/0-552 kPa/0-5.5 Bar with Retard) 19 Water Supply Main Drain Valve - Flow Test 20 Water Supply Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar) 21 Drain Connection Kit 22 Gauge Valve 23 System Main Drain Valve 24 Series 748 Ball Check Valve
14a
14b
Note 1
10
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Exploded View Drawing – Trim ComponentsSERIES 768 FIRELocK nXt DRy vaLvE (oPtIonaL accESSoRIES aLSo SHown)
From WaterSupply
2
3
ToSystem
From SystemAir Feed
24
15
9
8
23
14
16
6
1025
17
1318
22
1920
22
12
7
11
1
22
4
21
5
ALocation
A
To Drip CupLocation
A
To DripCup
Location
A
To DripCup
Location
Note 1
Bill of Materials 1 Series 768 FireLock NXT Dry Valve 2 FireLock Rigid Coupling 3 Water Supply Main Control Valve 4 Drain Swing Check Valve 5 Drip Cup with Cap 6 Alarm Pressure Switch 7 Series 729 Drip Check Valve 8 Diaphragm-Charge-Line Ball Valve (Normally Open) 9 3-in-1 Strainer/Check/Restrictor Assembly 10 Series 760 Water Motor Alarm (Optional/Sold Separately) 11 Alarm Test Ball Valve 12 Diaphragm-Charge-Line Pressure Gauge (0 – 300 psi/0 – 2068 kPa/0 – 20.7 Bar) 13 Series 749 Auto Drain 14 Series 746-LPA Dry Accelerator Assembly (Optional/Sold Separately) 15 Series 776 Low-Pressure Actuator 16 Air Manifold 17 Air Supervisory Pressure Switch 18 System Pressure Gauge (0 – 80 psi/0 – 552 kPa/0 – 5.5 Bar with Retard) 19 Water Supply Main Drain Valve – Flow Test 20 Water Supply Pressure Gauge (0 – 300 psi/0 – 2068 kPa/0 – 20.7 Bar) 21 Drain Connection Kit 22 Gauge Valve 23 System Main Drain Valve 24 Series 748 Ball Check Valve 25 Water Motor Alarm Shutoff Valve (Normally Open)*
*Item 25, water motor alarm shutoff valve, can be closed to prevent water from flowing into the Series 760 Water Motor alarm during conditions that are not favorable for the alarm to sound (i.e. during a trip test).
14a
14b
11
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Series 769, FireLock NXT Deluge Valve
Series 769
FIRELocK nXt® DELugE vaLvERequest publication 30.81
PRE-tRImmED *
VNIIPO
Valve Size Vic-Quick Riser Assemblies
[mm]
Wet Pilot Valve with VQR
Valve with Series 753-E Electric
Solenoid with VQR
Dry Pilot Valve with Series 776
Low Pressure Actuator with VQR
Price Each
48,3 €5497,76 €6094,11 €6918,30
60,3 5497,76 6094,11 6918,30
73,0 6557,85 7152,40 8010,37
76,1 6557,85 7152,40 8010,37
88,9 6557,85 7152,40 8010,37
114,3 7593,92 8190,20 8541,32
165,1 9162,05 9758,39 10831,74
168,3 9162,07 9758,39 10831,74
219,1 12860,98 13731,47 12997,17
European trim configurations are not available in 73 mm pipe sizes.
NOTE: All devices are non-returnable and non-cancellable.
Some assembly required - instructions included.
For trim diagrams, see following page(s).
Order optional accessories as separate items.
Vic-Quick Riser configuration is required for VdS approval.
12
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Exploded View Drawing – Trim ComponentsSERIES 769 FIRELocK nXt DELugE vaLvE – wItH PnEumatIc RELEaSE (DRy PILot) DELugE tRIm (oPtIonaL accESSoRIES aLSo SHown)
From WaterSupply
2
3
1
11
19
20
14
13
16
18
1722
15
6
2112
8
4
7
9
10
From SystemAir Feed
To PilotLine
To System
22
5
ALocation
A
To DripCup
Location
A
To Drip CupLocation
A
To Drip CupLocation
Note 1
Bill of Materials 1 Series 769 FireLock NXT Deluge Valve 2 FireLock Rigid Coupling 3 Water Supply Main Control Valve 4 Drain Swing Check Valve 5 Drip Cup with Cap 6 Alarm Pressure Switch 7 Series 729 Drip Check Valve 8 Diaphragm-Charge-Line Ball Valve (Normally Open) 9 3-in-1 Strainer/Check/Restrictor Assembly 10 Series 760 Water Motor Alarm (Optional/Sold Separately) 11 Alarm Test Ball Valve 12 Diaphragm-Charge-Line Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7Bar) 13 Series 749 Auto Drain 14 Series 776 Low-Pressure Actuator 15 Air Manifold 16 Air Supervisory Pressure Switch 17 Water Supply Main Drain Valve - Flow Test 18 Water Supply Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar) 19 Drain Connection Kit 20 System Main Drain Valve 21 Series 755 Manual Pull Station 22 Gauge Valve
13
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Exploded View Drawing – Trim ComponentsSERIES 769 FIRELocK nXt DELugE vaLvE – wItH PnEumatIc RELEaSE (DRy PILot) DELugE tRIm (oPtIonaL accESSoRIES aLSo SHown)
Bill of Materials 1 Series 769 FireLock NXT Deluge Valve 2 FireLock Rigid Coupling 3 Water Supply Main Control Valve 4 Drain Swing Check Valve 5 Drip Cup with Cap 6 Alarm Pressure Switch 7 Series 729 Drip Check Valve 8 Diaphragm-Charge-Line Ball Valve (Normally Open – Lockable) 9 3-in-1 Strainer/Check/Restrictor Assembly 10 Series 760 Water Motor Alarm (Optional/Sold Separately) 11 Alarm Test Ball Valve (Normally Closed – Lockable) 12 Diaphragm-Charge-Line Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar) 13 Series 749 Auto Drain 14 Series 776 Low-Pressure Actuator 15 Air Manifold 16 Air Supervisory Pressure Switch 17 Water Supply Main Drain Valve - Flow Test 18 Water Supply Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar) 19 Drain Connection Kit 20 System Main Drain Valve 21 Series 755 Manual Pull Station 22 Gauge Valve 23 Alarm Line Ball Valve (Normally Open – Lockable) 24 Water Motor Alarm Shutoff Valve (Normally Open – Lockable)*
Note 1
2
3
From WaterSupply
10
1
11
19
20
16
1817
22
15
6
21
14
23
13
12
8
24
4
7
9
22
5
From SystemAir Feed
To PilotLine
To System
ALocation
ATo Location
BLocation
B
To Drip CupLocation
B
To Drip CupLocation
B
To Drip CupLocation
14
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Exploded View Drawing – Trim ComponentsSERIES 769 FIRELocK nXt DELugE vaLvE – wItH HyDRauLIc RELEaSE (wEt PIoLot) DELugE tRIm oPtIonaL accESSoRIES aLSo SHown)
From WaterSupply
2
3
1
11
16
17
13
19
15
14 19
6
10
18
124
7
9
To Wet PilotSystem
To System
8
5
ALocation
A
To DripCup
Location
A
To Drip CupLocation
Note 1
Bill of Materials 1 Series 769 FireLock NXT Deluge Valve 2 FireLock Rigid Coupling 3 Water Supply Main Control Valve 4 Drain Swing Check Valve 5 Drip Cup with Cap 6 Alarm Pressure Switch 7 Series 729 Drip Check Valve 8 Diaphragm-Charge-Line Ball Valve (Normally Open) 9 3-in-1 Strainer/Check/Restrictor Assembly 10 Series 760 Water Motor Alarm (Optional/Sold Separately) 11 Alarm Test Ball Valve12 Diaphragm-Charge-Line Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar)13 Series 749 AutoDrain14 Water Supply Main Drain Valve – Flow Test15 Water Supply Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar)16 Drain Connection Kit17 System Main Drain Valve18 Series 755 Manual Pull Station19 Gauge Valve
15
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Exploded View Drawing – Trim ComponentsSERIES 769 FIRELocK nXt DELugE vaLvE – wItH HyDRauLIc RELEaSE (wEt PILot) DELugE tRIm oPtIonaL accESSoRIES aLSo SHown)
10
6
16
To System
To Wet PilotSystem
18
1
11
17
21
13
19
15
19
12
20
4
7
9
8
5
14
ATo Location
BLocation
B
To DripCup
Location
B
To Drip CupLocation
2
3
From WaterSupply
ALocation
Bill of Materials 1 Series 769 FireLock NXT Deluge Valve 2 FireLock Rigid Coupling 3 Water Supply Main Control Valve 4 Drain Swing Check Valve 5 Drip Cup with Cap 6 Alarm Pressure Switch 7 Series 729 Drip Check Valve 8 Diaphragm-Charge-Line Ball Valve (Normally Open – Lockable) 9 3-in-1 Strainer/Check/Restrictor Assembly 10 Series 760 Water Motor Alarm (Optional/Sold Separately) 11 Alarm Test Ball Valve (Normally Closed – Lockable)12 Diaphragm-Charge-Line Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar)13 Series 749 AutoDrain14 Water Supply Main Drain Valve – Flow Test15 Water Supply Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar)16 Drain Connection Kit17 System Main Drain Valve18 Series 755 Manual Pull Station19 Gauge Valve20 Alarm Line Ball Valve (Normally Open – Lockable) 21 Water Motor Alarm Shutoff Valve (Normally Open – Lockable)*
Note 1
16
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Exploded View Drawing – Trim ComponentsSERIES 769 FIRELocK nXt DELugE vaLvE – wItH ELEctRIc RELEaSE DELugE tRIm oPtIonaL accESSoRIES aLSo SHown)
From WaterSupply
2
3
1
11
16
18
13
17
15
14
5
17
6
10
19
12
20
8
4
7
9
To System
ALocation
A
To DripCup
LocationA
To DripCup
Location
A
To Drip CupLocation
Note 1
Bill of Materials 1 Series 769 FireLock NXT Deluge Valve 2 FireLock Rigid Coupling 3 Water Supply Main Control Valve 4 Drain Swing Check Valve 5 Drip Cup with Cap 6 Alarm Pressure Switch 7 Series 729 Drip Check Valve 8 Diaphragm-Charge-Line Ball Valve (Normally Open) 9 3-in-1 Strainer/Check/Restrictor Assembly 10 Series 760 Water Motor Alarm (Optional/Sold Separately) 11 Alarm Test Ball Valve 12 Diaphragm-Charge-Line Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar)13 Series 749 AutoDrain14 Water Supply Main Drain Valve – Flow Test15 Water Supply Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar)16 Drain Connection Kit17 Gauge Valve18 System Main Drain Valve19 Series 755 Manual Pull Station20 Series 753-E Solenoid Valve
17
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Exploded View Drawing – Trim ComponentsSERIES 769 FIRELocK nXt DELugE vaLvE – wItH ELEctRIc RELEaSE DELugE tRIm oPtIonaL accESSoRIES aLSo SHown)
Bill of Materials 1 Series 769 FireLock NXT Deluge Valve 2 FireLock Rigid Coupling 3 Water Supply Main Control Valve 4 Drain Swing Check Valve 5 Drip Cup with Cap 6 Alarm Pressure Switch 7 Series 729 Drip Check Valve 8 Diaphragm-Charge-Line Ball Valve (Normally Open – Lockable) 9 3-in-1 Strainer/Check/Restrictor Assembly 10 Series 760 Water Motor Alarm (Optional/ Sold Separately) 11 Alarm Test Ball Valve (Normally Closed – Lockable) 12 Diaphragm-Charge-Line Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar) 13 Series 749 AutoDrain 14 Water Supply Main Drain Valve – Flow Test 15 Water Supply Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar) 16 Drain Connection Kit 17 Gauge Valve 18 System Main Drain Valve 19 Series 755 Manual Pull Station 20 Series 753-E Solenoid Valve 21 Alarm Line Ball Valve (Normally Open – Lockable) 22 Water Motor Alarm Shutoff Valve (Normally Open – Lockable)*
1
11
16
1813
17
21
14
5
17
6
19
12
20
8
4
7
22
9
10
2
3
ATo Location
From WaterSupply
To System
ALocation
B
To Drip CupLocation
B
To Drip CupLocation
B
To Drip CupLocation
BLocation
Note 1
18
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Series 769, FireLock NXT Preaction Valve
Series 769
FIRELocK nXt® PREactIon vaLvERequest publication 30.82
VNIIPO
FIRELocK nXt SERIES 769 wItH vIc-QuIcK RISER PRE-tRImmED
Valve Size
Non-Interlock or Single Interlock Pneumatic
Actuation with Series 776-LPA*
Series 753-E Electric Solenoid Actuation
Non-Interlock Pneumatic Electric with Series 776LPA
and 753E
Inches Price Each
Groove by Groove
48,3 €7403,05 €6546,13 +
60,3 7403,05 6546,13 +
73,0 7501,00 7720,19 +
76,1 7501,00 7720,19 +
88,9 7704,20 7720,19 +
114,3 7926,61 8898,58 +
165,1 9582,93 11032,89 +
168,3 9875,83 11032,89 +
219,1 10006,68 14997,06 +
NOTE: All devices are non-returnable and non-cancellable.
+ Quoted on application. Contact Victaulic for pricing and availability.
For trim diagrams, see following page(s).
Order optional accessories as separate items.
Valve Size
Double Interlock Pneumatic/Pneumatic Actuator
with Series 798 DPA
Double Interlock Pneumatic/Electric
with Series 768
[mm] Price Each
Groove by Groove
48,3 €6189,65 €7743,18
60,3 6189,65 7743,18
73,0 6834,45 9387,76
76.1 6834,45 9387,76
88,9 7110,36 9387,76
114,3 7252,12 10649,20
165,1 9102,67 12934,69
168,3 8347,13 12934,69
219,1 10221,23 14630,12
19
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Exploded View Drawing – Trim ComponentsSERIES 769 FIRELocK nXt PREactIon vaLvE – wItH non-IntERLocKED, PnEumatIc RELEaSE tRIm (oPtIonaL accESSoRIES aLSo SHown)
From WaterSupply
2
3
1
11
20
22
24
14
13
21
16
19
21
17
18
21
15
6
10
2312
8
4
7
9
From SystemAir Feed
To System
To PilotLine
5
ALocation
A
To DripCup
Location
A
To DripCup
Location
A
To DripCup
Location
Bill of Materials 1 Series 769 FireLock NXT Preaction Valve 2 FireLock Rigid Coupling 3 Water Supply Main Control Valve 4 Drain Swing Check Valve 5 Drip Cup with Cap 6 Alarm Pressure Switch 7 Series 729 Drip Check Valve 8 Diaphragm-Charge-Line Ball Valve (Normally Open) 9 3-in-1 Strainer/Check/Restrictor Assembly 10 Series 760 Water Motor Alarm (Optional/Sold Separately) 11 Alarm Test Ball Valve 12 Diaphragm-Charge-Line Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar) 13 Series 749 Auto Drain 14 Series 776 Low-Pressure Actuator 15 Air Manifold 16 Air Supervisory Pressure Switch 17 System Pressure Gauge (0-80 psi/0-552 kPa/0-5.5 Bar with Retard) 18 Water Supply Main Drain Valve - Flow Test 19 Water Supply Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar) 20 Drain Connection Kit 21 Gauge Valve 22 System Main Drain Valve 23 Series 755 Manual Pull Station 24 Series 748 Ball Check Valve
Note 1
20
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Exploded View Drawing – Trim ComponentsSERIES 769 FIRELocK nXt PREactIon vaLvE – wItH non-IntERLocKED, PnEumatIc/ELEctRIc RELEaSE tRIm (oPtIonaL accESSoRIES aLSo SHown)
2
3
From WaterSupply
1
11
20
22
24
14
13
21
16
19
21
17
18
21
15
6
10
23
26
1225
8
4
7
9
From SystemAir Feed
To System
5
ALocation
A
To Drip CupLocation
A
To Drip CupLocation
A
To Drip CupLocation
A
To DripCup
Location
Bill of Materials 1 Series 769 FireLock NXT Preaction Valve 2 FireLock Rigid Coupling 3 Water Supply Main Control Valve 4 Drain Swing Check Valve 5 Drip Cup with Cap 6 Alarm Pressure Switch 7 Series 729 Drip Check Valve 8 Diaphragm-Charge-Line Ball Valve (Normally Open) 9 3-in-1 Strainer/Check/Restrictor Assembly 10 Series 760 Water Motor Alarm (Optional/Sold Separately) 11 Alarm Test Ball Valve 12 Diaphragm-Charge-Line Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar) 13 Series 749 Auto Drain 14 Series 776 Low-Pressure Actuator 15 Air Manifold 16 Air Supervisory Pressure Switch 17 System Pressure Gauge (0-80 psi/0-552 kPa/0-5.5 Bar with Retard) 18 Water Supply Main Drain Valve - Flow Test 19 Water Supply Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar) 20 Drain Connection Kit 21 Gauge Valve 22 System Main Drain Valve 23 Series 755 Manual Pull Station 24 Series 748 Ball Check Valve 25 Series 753-E Solenoid Valve 26 Series 746-LPA Dry Accelerator (Optional/Sold Separately)
Note 1
26b
26a
21
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Exploded View Drawing – Trim ComponentsSERIES 769 FIRELocK nXt PREactIon vaLvE – wItH SIngLE-IntERLocKED, PnEumatIc RELEaSE tRIm (oPtIonaL accESSoRIES aLSo SHown)
ALocation
2
3
From WaterSupply
1
11
20
22
14
13
21
16
19
21
17
18
5
21
15
6
10
23
25
12
8
4
7
9
To PilotLine
From SystemAir Feed
To System
24
A
To DripCup
Location
A
To DripCup
Location
A
To Drip CupLocation
Bill of Materials 1 Series 769 FireLock NXT Preaction Valve 2 FireLock Rigid Coupling 3 Water Supply Main Control Valve 4 Drain Swing Check Valve 5 Drip Cup with Cap 6 Alarm Pressure Switch 7 Series 729 Drip Check Valve 8 Diaphragm-Charge-Line Ball Valve (Normally Open) 9 3-in-1 Strainer/Check/Restrictor Assembly 10 Series 760 Water Motor Alarm (Optional/Sold Separately) 11 Alarm Test Ball Valve 12 Diaphragm-Charge-Line Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar) 13 Series 749 Auto Drain 14 Series 776 Low-Pressure Actuator 15 Air Manifold 16 Air Supervisory Pressure Switch 17 System Pressure Gauge (0-80 psi/0-552 kPa/0-5.5 Bar with Retard) 18 Water Supply Main Drain Valve - Flow Test 19 Water Supply Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar) 20 Drain Connection Kit 21 Gauge Valve 22 System Main Drain Valve 23 Series 755 Manual Pull Station 24 Series 748 Ball Check Valve 25 Series 746-LPA Dry Accelerator (Optional/Sold Separately)
Note 1
25b
25a
22
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Exploded View Drawing – Trim ComponentsSERIES 769 FIRELocK nXt PREactIon vaLvE – wItH SIngLE-IntERLocKED, ELEctRIc RELEaSE tRIm DoubLE-IntERLocKED, ELEctRIc RELEaSE (ELEctRIc-PnEumatIc/ELEctRIc) tRIm (oPtIonaL accESSoRIES aLSo SHown)
2
3
From WaterSupply
1
15
11
21
23
14
13
20
18
20
16
17
5
20
19
6
10
22
12
8
4
7
9
From SystemAir Feed
To System
ALocation
A
To DripCup
Location A
To DripCup
Location
A
To Drip CupLocation
Note 1
Bill of Materials 1 Series 769 FireLock NXT Preaction Valve 2 FireLock Rigid Coupling 3 Water Supply Main Control Valve 4 Drain Swing Check Valve 5 Drip Cup with Cap 6 Alarm Pressure Switch 7 Series 729 Drip Check Valve 8 Diaphragm-Charge-Line Ball Valve (Normally Open) 9 3-in-1 Strainer/Check/Restrictor Assembly 10 Series 760 Water Motor Alarm (Optional/Sold Separately) 11 Alarm Test Ball Valve 12 Diaphragm-Charge-Line Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar) 13 Series 749 Auto Drain 14 Series 753-E Solenoid Valve 15 Air Supervisory Pressure Switch** 16 System Pressure Gauge (0-80 psi/0-552 kPa/0-5.5 Bar with Retard) 17 Water Supply Main Drain Valve - Flow Test 18 Water Supply Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar) 19 Drain Connection Kit 20 Gauge Valve 21 System Main Drain Valve 22 Series 755 Manual Pull Station 23 Series 748 Ball Check Valve
**Item #15 is optional/sold separately (or standard when VQR assembly is ordered) for single-interlocked, electric release trim.**Item #15 is standard for double-interlocked, electric release (electric-pneumatic/electric) trim.
23
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Exploded View Drawing – Trim ComponentsSERIES 769 FIRELocK nXt PREactIon vaLvE – wItH DoubLE-IntERLocKED, ELEctRIc/PnEumatIc RELEaSE tRIm (oPtIonaL accESSoRIES aLSo SHown)
2
3
From WaterSupply
30
1
11
20
22
24
14
27
13
21
16
19
21
17
18
5
21
15
6
10
23
26
25
12
8
4
29
28
7
9
From SystemAir Feed
To System
NOTE: When installing the optional Series 746-LPA Dry Accelerator, relocate the auto vent to the location of the indicated plug.
ALocation
B
To Drip CupLocation
B
To DripCup
Location
B
To DripCup
Location
25a
25b
Bill of Materials 1 Series 769 FireLock NXT Preaction Valve 2 FireLock Rigid Coupling 3 Water Supply Main Control Valve 4 Drain Swing Check Valve 5 Drip Cup with Cap 6 Alarm Pressure Switch 7 Series 729 Drip Check Valve 8 Diaphragm-Charge-Line Ball Valve (Normally Open) 9 3-in-1 Strainer/Check/Restrictor Assembly 10 Series 760 Water Motor Alarm (Optional/Sold Separately) 11 Alarm Test Ball Valve 12 Diaphragm-Charge-Line Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar) 13 Series 749 Auto Drain 14 Series 767 Electric/Pneumatic Actuator 15 Air Manifold 16 Air Supervisory Pressure Switch 17 System Pressure Gauge (0-80 psi/0-552 kPa/0-5.5 Bar with Retard) 18 Water Supply Main Drain Valve - Flow Test 19 Water Supply Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar) 20 Drain Connection Kit 21 Gauge Valve 22 System Main Drain Valve 23 Series 755 Manual Pull Station 24 Series 748 Ball Check Valve 25 Series 746-LPA Dry Accelerator (Optional/Sold Separately) 26 Upper Chamber Strainer (100 Mesh) 27 Upper Chamber Pressure Gauge for Series 767 Electric/Pneumatic Actuator 28 Auto Vent for Series 767 Electric/ Pneumatic Actuator 29 Upper Chamber Inlet Restrictor .032-inch) for Series 767 Electric/ Pneumatic Actuator 30 Upper Chamber Check Valve (¼-inch) for Series 767 Electric/Pneumatic Actuator
Note 1
24
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Exploded View Drawing – Trim ComponentsSERIES 769 FIRELocK nXt PREactIon vaLvE – wItH DoubLE-IntERLocKED, PnEumatIc RELEaSE tRIm (oPtIonaL accESSoRIES aLSo SHown)
A
To Drip CupLocation
From WaterSupply
NOTE: When installing the optional Series 746-LPA Dry Accelerator(s), relocate the auto vent to the location of
the indicated plug.
1
21
11
16
22
24
26
28
27
26
13
21
16
19
21
21
17
18
5
15
6
10
23
14
20
29
25
15
3025
12
8
4
7
9
From SystemAir Feed
To PilotLine
To System
26a PilotLine
26b SystemLine
2
3
A
To Drip CupLocation
A
To Drip CupLocation
25a
25b
ALocation
Bill of Materials 1 Series 769 FireLock NXT Preaction Valve 2 FireLock Rigid Coupling 3 Water Supply Main Control Valve 4 Drain Swing Check Valve 5 Drip Cup with Cap 6 Alarm Pressure Switch 7 Series 729 Drip Check Valve 8 Diaphragm-Charge-Line Ball Valve (Normally Open) 9 3-in-1 Strainer/Check/Restrictor Assembly 10 Series 760 Water Motor Alarm (Optional/Sold Separately) 11 Alarm Test Ball Valve 12 Diaphragm-Charge-Line Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar) 13 Series 749 Auto Drain 14 Series 798 Pneumatic/Pneumatic Actuator 15 Air Manifold 16 Air Supervisory Pressure Switch 17 System Pressure Gauge (0-80 psi/0-552 kPa/0-5.5 Bar with Retard) 18 Water Supply Main Drain Valve - Flow Test 19 Water Supply Pressure Gauge (0-300 psi/0-2068 kPa/0-20.7 Bar) 20 Drain Connection Kit 21 Gauge Valve 22 System Main Drain Valve 23 Series 755 Manual Pull Station 24 Series 748 Ball Check Valve 25 Series 746-LPA Dry Accelerator (Optional/Sold Separately) 26 Air Feed Valve Assembly 26a Pilot Line Fill Valve and Shutoff Valve (Shutoff Valve has Yellow Handle) 26b System Line Fill Valve and Shutoff Valve (Shutoff Valve has Yellow Handle) 27 System Air Line Strainer (100 Mesh) 28 Pilot Line Strainer (100 Mesh) 29 Pilot Line Pressure Gauge (0-80 psi/0-552 kPa/0-5.5 Bar with Retard) 30 Auto Vent for Series 798 Pneumatic/ Pneumatic Actuators
Note 1
25
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Device Replacement Parts
Series 751, 756, 758 Clapper Seal Kit with Cover Gasket
Device Replacement PartsSERIES 751, 756, 758 cLaPPER SEaL KIt wItH covER gaSKEt
Product IDSize
[mm]Price Each
DRPCSK000000048 48,3 – 60,3 €59,52
DRPCSK000000073 73,0 – 88,9 85,36
DRPCSK756000114 114,3 125,37
DRPCSK756000165 165,1 – 168,3 198,70
DRPCSK000000219 219,1 228,25
Series 751 Clapper and Seal Kit Assembly (114, 165, and 168mm)
SERIES 751 cLaPPER anD SEaL KIt aSSEmbLy
(114 mm, 165 mm and 168 mm)
Product IDSize
[mm] Price Each
DRPCSA751000114 114,3 €513,90
DRPCSA751000165 165,1 – 168,3 725,79
Series 751 Clapper and Seal Kit Assembly (all sizes except 114, 165, 168, and 89 mm CE)
SERIES 751 cLaPPER anD SEaL KIt aSSEmbLy
(All sizes except 114 mm, 165 mm, 168 mm and 89 mm CE)
Product IDSize
[mm] Price Each
DRPCSA000000048 48,3 – 60,3 €474,28
DRPCSA000000073 73,0 – 88,9 474,28
DRPCSA000000219 219,1 1044,00
Series 751 Cover Bolts
SERIES 751 covER boLtS
Product IDSize
[mm] Price Each
DRPCB0000000048 48,3 – 60,3 €0,72
DRPCB0000000073 73,0 – 88,9 0,77
DRPCB0000000114 114,3 – 168,3 1,06
DRPCB0000000219 219,1 1,34
NOTE: Items listed in shaded areas are non-cancellable and n on-returnable.
Series 751 Clapper Spring
SERIES 751 cLaPPER SPRIng
Product IDSize
[mm] Price Each
DRPCSP000000048 48,3 – 60,3 €75,52
DRPCSP000000073 73,0 – 88,9 116,64
DRPCSP000000114 114,3 106,41
DRPCSP000000165 165,1 – 168,3 102,51
DRPCSP000000219 219,1 130,78
NOTE: Items listed in shaded areas are non-cancellable and non-returnable.
Series 751 Spacer
SERIES 751 SPacER
Product IDSize
[mm] Price Each
DRPSPA0000FM048 48,3 – 60,3 €2,17
DRPSPA0000FM073 73,0 – 88,9 1,91
DRPSPA0000FM114 114,3 – 165.1 – 168.3 2,17
DRPSPA0000FM219 219,1 3,69
NOTE: Items listed in shaded areas are non-cancellable and non-re-turnable.
Series 751 Clapper Shaft – FM
SERIES 751 cLaPPER SHaFt
Product IDSize
[mm] Price Each
DRPCSH0000FM048 48,3 – 60,3 €34,97
DRPCSH0000FM073 73,0 – 88,9 34,97
DRPCSH0000FM114 114,3 48,37
DRPCSH0000FM165 165,1 – 168,3 53,75
DRPCSH0000FM219 219,1 78,31
NOTE: Items listed in shaded areas are non-cancellable and non-returnable.
Series 751 Clapper Shaft – CE
SERIES 751 cLaPPER SHaFt
0786
Product IDSize
[mm] Price Each
DRPCSH0000CE089 88,9 €42,22
DRPCSH0000CE114 114,3 42,22
DRPCSH0000CE165 165,1 – 168,3 44,66
DRPCSH0000CE219 219,1 108,82
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
26
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Series 751 Clapper Shaft O-Ring – CE
SERIES 751 cLaPPER SHaFt o-RIng
0786
Product IDSize
[mm] Price Each
DRPCSO0000CE089 88,9 €0,74
DRPCSO0000CE114 114,3 – 168,3 0,74
DRPCSO0000CE219 219,1 0,74
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
Series 768/769 Diaphragm
SERIES 768/769 DIaPHRagm
Product IDSize
[mm] Price Each
TRPD00000000060 48,3 – 60,3 €55,86
TRPD00000000073 73,0 – 88,9 36,93
TRPD00000000114 114,3 – 219,1 36,93
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
RE-buILD KItS FoR SERIES 756/758 anD FIRELocK nXt vaLvES
Size [mm] Price Each
Series 756 and 758 Re-Build Kit Includes: Clapper Seal, Seal Ring, Seal Washer, Bolt Seal, Clapper Shaft, Latch Shaft, Latch Spring, Latch Spring Insert Tool, Spacer, Cover Plate Gasket, Shaft Seal, Piston
Shaft, Diaphragm, Compression Spring, Washer for Piston Shaft Retaining Bolt, O-Ring, Clapper Spring, Piston Shaft Protective Sleeve, Piston Shaft Lubricant
48,3 – 60,3 +
73,0 – 88,9 +
114,3 +
168,3 +
219,1 + NXT Re-Build Kit
Indludes: Seal, Seal Ring, Washer Seal, Self-Sealing Lock Washer, Clapper Shaft, Latch Shaft, Clapper Torsion Spring, Latch Torsion Spring, Spring Insert Tools,
Diaphragm, Gasket
48,3 – 60,3 +
73,0 – 88,9 +
114,3 +
168,3 +
219,1 +
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
trim optional Parts
Series 751 Drain Connection Kit – FM
Trim Optional PartsSERIES 751 DRaIn connEctIon KIt
From Drain Valve(System side)
To Drain
Product IDSize
[mm] Price Each
TOPDCK7510FM048 48,3 – 60,3 €126,86
TOPDCK7510FM073 73,0 – 88,9 148,91
TOPDCK7510FM114 114,3 191,62
TOPDCK7510FM165 165,1 – 168,3 191,62
TOPDCK7510FM219 219,1 191,62
Series 751 Drain Connection Kit – CE
SERIES 751 DRaIn connEctIon KIt
0786
TO DRAIN
RED PAINTED
RED PAINTED
FROM DRAIN VALVE
Product IDSize
[mm] Price Each
TOPDCK7510CE076 76,1 – 88,9 €551,86
TOPDCK7510CE114 114,3 551,86
TOPDCK7510CE165 165,1 – 168,3 551,86
TOPDCK7510CE219 219,1 551,86
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
Series 768/769 FireLock NXT Deluge/Preaction Systems Drain Connection Kit
SERIES 768/769 FIRELocK nXt DELugE/PREactIon SyStEmS DRaIn connEctIon KIt
Product IDSize
Inches Price Each
TOPDCK768000048 1Z\x– 2 €302,73
TOPDCK768000073 2Z\x– 3 401,82
TOPDCK768000114 4 – 8 321,99
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
27
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
Series 752 Retard Chamber – FM
SERIES 752 REtaRD cHambER
Product IDSize
[mm] Price Each
TOPRC07520FM000 48,3 – 219,1 €398,71
Series 752 Retard Chamber – CE
SERIES 752 REtaRD cHambER
0786
Product IDSize
[mm] Price Each
TOPRC07520CE000 48,3 – 219,1 €398,71
Series 752V Retard Vent Kit
SERIES 752v REtaRD vEnt KIt
Pipe toOpen Drain
Product IDSize
[mm] Price Each
TOPRVK752000000 219,1 €181,47
Series 746-LPA Dry Accelerator
SERIES 746-LPa DRy accELERatoR *
Product ID Price Each
TOPDAL746000000 €948,27
* For use only with Series 768/769 FireLock NXT Valves.
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
Series 760 Water Motor Alarm – UL, FM, CE, VdS
SERIES 760 watER motoR aLaRm
Product ID Description Price Each
TOPWMA760000000 Water Motor Alarm with Wye Strainer €791,04
Series 757 Air Maintenance Trim Assembly for Series 768/769
SERIES 757 aIR maIntEnancE tRIm aSSEmbLy
for Series 768 – 769
Product ID Price Each
TOPAMT757000000 €599,99
Series 757P Air Maintenance Trim Assembly for Series 768/769 with Pressure Switch
SERIES 757P aIR maIntEnancE tRIm aSSEmbLy
for Series 768 – 769 with Pressure Switch
Product ID PSI Price Each
TOPAMT757000001 13 – 18 €1187,93
TOPAMT757000002 25 – 40 922,85
Series 75D Water Column (Component Drain) Kit
28
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
SERIES 75D watER coLumn (comPonEnt DRaIn) KIt
Product ID Price Each
TOPWCK75D000000 €473,45
Series 755 Manual Pull Station
SERIES 755 manuaL PuLL StatIon
Product ID Price Each
TOPMPS755000000 €189,76
trim Replacement Parts
90° Drain Valve – FM
Trim Replacement Parts90° DRaIn vaLvE
Product IDSize
[mm] Price Each
TRPDV00000FM048 48,3 - 60,3 NPT €84,01
TRPDV00000FM073 73,0 - 88,9 NPT 110,40
TRPDV00000FM114 114,3 - 219,1 NPT 178,17
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
90° Drain Test Valve – CE
90° DRaIn tESt vaLvE
0786
Product IDSize
[mm] Price Each
TRPDV00000CE076 76,1 - 88,9 BSP €224,68
TRPDV00000CE114 114,3 - 219,1 BSP 233,12
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
90° Angle Valve for Series 768/769 FireLock NXT Valves
90° angLE vaLvE FoR SERIES 768/769 FIRELocK nXt vaLvES
Product IDSize
Inches Price Each
TRPDV0000000048 C\v (1Z\x– 2”) NPT €122,63
TRPDV0000000073 1Z\v (2Z\x– 3”) NPT 186,49
TRPDV0000000114 2 (4 – 8”) NPT 216,43
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
+ Quoted on application. Contact Victaulic for pricing and availability.
Series 722 Trim Ball Valve
29
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
SERIES 722 tRIm baLL vaLvE
0786
Product IDSize
InchesDescription
Price Each
TRPTBV000000014 Z\v Trim Ball Valve €14,81
TRPTBV000000021 Z\x Trim Ball Valve 15,61
TRPTBV0000CE021 Z\x Trim Ball Valve CE (Lockable) 23,54
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
Gauge Valve
gaugE vaLvE
Product IDSize
Inches Description Price Each
TRPGV0000000014 Z\v Gauge Valve Brass €36,84
TRPGV0000000021 Z\x Gauge Valve Brass 60,68
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
Series 748 Ball Check Valve
SERIES 748 baLL cHEcK vaLvE
Product IDSize
Inches Price Each
TRPBCV748000000 Z\x €59,24
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
Wye Strainer (Air/Water)
wyE StRaInER
(Air/Water)
Product IDSize
Inches DescriptionPrice Each
TRPWS0000000014 Z\v Wye Strainer Mesh 100 Brass €21,73
TRPWS0000000021 Z\x Wye Strainer Mesh 100 Brass 67,39
TRPWS0000000026 C\vWye Strainer Mesh 50 Brass – C\v NPT for Water Motor Alarm 100,10
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
Series 729 Ball Drip Assembly – FM
SERIES 729 baLL DRIP aSSEmbLy
Product IDSize
Inches Price Each
TRPBDA7290FM000 Z\x €77,07
Series 749 Ball Drip Assembly – CE
SERIES 749 baLL DRIP aSSEmbLy
0786
Product IDSize
Inches Price Each
TRPBDA7490CE000 Z\x” €90,93
Pressure Gauge Air/Water
PRESSuRE gaugE
Air/Water
Product IDSize
Inches DescriptionPrice Each
TRPPGW0000FM014 Z\vPressure Gauge Water 0 – 300 Ppsi/0 – 20 BAR FM €63,46
TRPPGW0000CE021 Z\xPressure Gauge Water 0 –350 psi/0 – 25 BAR CE 99,53
TRPPGW0000CE02R Z\xPressure Gauge Water 0 – 350 psi/0 – 25 BAR CE – Rear Mount 102,96
TRPPGA0000FM014 Z\vPressure Gauge Air/Water Retard 0 – 80 psi/0 – 250 psi/0 – 17 BAR FM 63,46
TRPPGA0000CE021 Z\xPressure Gauge Air/Water Retard 0 – 16 BAR CE 158,38
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
Restrictors
REStRIctoRS
Product ID Description Price Each
TRPR00000000125 Z\x x Z\v– Z\, (0,125) Orifice for S/757 €51,00
TRPR00000000063 Z\x x Z\v– Z\zn (0,063) Orifice 51,00
TRPR000000CE063 Z\x x Z\x– Z\zn (0,063) Orifice 51,00
TRPR000000FM063 Z\v x Z\v– Z\zn (0,063) Orifice 51,00
TRPR00000000032 Z\v x Z\v– Z\cx (0,032) Orifice 51,00
TRPR00000000070 Z\x– (0,070) Orifice 54,01
TRPR0075P000125 Z\x x Z\x– Z\, (0,125) Orifice for S/757P 61,96
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
Swing Check Valve
30
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
SwIng cHEcK vaLvE
Product IDSize
Inches Description Price Each
TRPSCV000000421 Z\x NPT 45° Brass €46,84
TRPSCV000000426 C\v NPT 45° Brass 55,02
TRPSCV000000921 Z\x NPT 90° Brass 55,02
TRPSCV000000926 C\v NPT 90° Brass 65,40
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
Drip Cup Kit
DRIP cuP KIt
Product ID Description Price Each
TRPDCK768000026 PVC Drip Cup Kit with Z\v” Reducer €82,50
Series 749 Auto Drain Assembly
SERIES 749 auto DRaIn aSSEmbLy
Product ID Price Each
TRPADA749000000 €95,02
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
Male Straight Piece for Series 749 Auto Drain Assembly
maLE StRaIgHt PIEcE
for Series 749 Auto Drain Assembly
Product IDSize
Inches Description Price Each
TRPMSP000000000 Z\v x C\, Brass €15,16
In-Line Spring Loaded Ball Check Valve for Series 757 Air Maintenance Trim
In-LInE SPRIng LoaDED baLL cHEcK vaLvE
for Series 757 Air Maintenance Trim
Product IDSize
Inches Price Each
TRPSLB000000014 Z\v €45,25
TRPSLB000000021 Z\x 27,58
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
3-in-1 Strainer/Check/Restrictor Assembly
3-In-1 StRaInER/cHEcK/REStRIctoR aSSEmbLy
Product IDSize
Inches Price Each
TRPSCR000000021 Z\x €88,28
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
Airline Manifold
aIRLInE manIFoLD
Product IDSize
Inches Price Each
TRPAM0000000021 Z\x €140,09
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
Series 776 Low Pressure Actuator
31
FireLock Devices
www.vIctauLIc.com vaLID FRom 31 JanuaRy 2011 untIL FuRtHER notIcE PL2011-FaD-Eu-EuRo
SERiES 776 Low PRESSuRE ActuAtoR
Product IDSize
Inches Price Each
TRPLPA776000014 Z\v €1370,22
TRPLPA776000021 Z\x 1370,22
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
Replacement Kit for Series 776 Low Pressure Actuator
REPLAcEmEnt kit FoR SERiES 776 Low PRESSuRE ActuAtoR
Product ID Price Each
TRPRKA776000000 €87,46
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
Auto vEnt ASSEmbLy FoR 776 ActuAtoR
Size [mm] Price Each
21,3 +
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
Series 798 Double Pneumatic Actuator
SERiES 798 DoubLE PnEumAtic ActuAtoR
Product ID Price Each
TRPDPA798000000 €1694,47
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
Series 753E Solenoid Actuator
SERiES 753E SoLEnoiD ActuAtoR
Product ID Description Price Each
TRPSA0753000000 24 VDC NEMA 4 €570,44
TRPSA075300000E 24 VDC NEMA 4 Explosion Proof 596,29
Replacement Coil Kit for Series 753E Solenoid Actuator
REPLAcEmEnt coiL kit FoR SERiES 753E SoLEnoiD ActuAtoR
Product ID Price Each
TRPRCK000000000 €288,43
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
Air Regulator for Series 757 Air Maintenance Trim
AiR REguLAtoR
for Series 757 Air Maintenance Trim
Product IDSize
Inches Description Price Each
TRPAR0000000000 Z\x” 5 – 60 psi with Gauge €309,68
Repair Kit for Series 746 Dry Accelerator
REPAiR kit FoR SERiES 746 DRy AccELERAtoR
Product ID Price Each
TRPRKA746000000 €131,93
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
Electrical Accessories
32
FireLock Devices
www.victAuLic.com vALiD FRom 31 JAnuARy 2011 untiL FuRtHER noticE PL2011-FAD-Eu-EuRo
Pressure Switches
Electrical AccessoriesPRESSuRE SwitcHES
Model Number Type of Pressure Switch
No. of SPDT
Switches
Adjust. Press. Range
(psi) Price Each
EPS10-1 Alarm Pressure Switch 1 4 – 20 €195,78
EPS10-2 Alarm Pressure Switch 2 4 – 20 219,17
EPS10-2 VdS Alarm Pressure Switch 2 4 – 20 219,17
EPS40-1 Supervisory Switch 1 10 – 100 195,78
EPS40-2 Supervisory Switch 2 10 – 100 219,17
EPS45-2V † Supervisory High/Low 2 10 – 20 +
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
† Preset pressure switch for Series 768 Dry and Series 769 Preaction and Deluge NXT Valves.
Alarm Release Panels
ALARm RELEASE PAnELS
Model Number Description Price Each
PDRP-2001E Deluge – Preaction Control Panel, 240 VAC €3586,63
ANN-80 80-Character LCD Serial Annunciator +
ANN-RLY Remote Relay +
ANN-LED LED Annunciator +
CAC-5X Class A Converter (2 Required) +
BAT-12260 Battery 12, 26AH +
4XTM Transmitter Module † +
BB-17 Battery Box +
71252 4.7k End-of-Line Relay Assembly +
BAT-1270 Battery, 12V, 7AH 160,13
BAT-12120 Battery, 12V, 12AH 365,31
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
+ Quoted on application. Contact Victaulic for pricing and availability.
† Contact Victaulic for availability.
Electric Pull Station
ELEctRic PuLL StAtionModel Price Each
2099-9754 €168,32
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
Tamper Kits
tAmPER kitSModel Description Price Each
546-7000 Tamper Kit - WFD, WFDT, OSY2, PIBV2 €52,95
546-8000 Tamper Kit - EPS Series 88,97
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
Alarm Bells
ALARm bELLS
ModelBell Size
[mm] Voltage Polarized Price Each
SSV120-6 168,3 120VAC No €68,08
SSV120-8 219,1 120VAC No 91,27
SSV120-10 273,0 120VAC No 107,16
SSM24-6 168,3 24VDC Yes 93,17
SSM24-8 219,1 24VDC Yes 115,54
SSM24-10 273,0 24VDC Yes 118,52
NOTE: Items listed in shaded areas are non-cancellable and non- returnable.
33
FireLock Devices
www.victAuLic.com vALiD FRom 31 JAnuARy 2011 untiL FuRtHER noticE PL2011-FAD-Eu-EuRo
Terms and Conditions of Sale
tERmS anD conDItIonS oF SaLE1. ACCEPTANCE: No contract shall be valid unless accepted in writing by seller. Verbal orders as well as deviations of our general terms and conditions of sale are not valid unless accepted in writing. Seller’s delivery consists only of the goods, documents and services as specified in the quotation. Acceptance of a quotation by Buyer includes also his acceptance of Seller’s general terms and conditions of sales and the present terms and conditions supersede any contrary conditions of Buyer. 2. VALIDITY: Unless otherwise agreed, Seller’s quotations are valid for 30 days. After this period they are subject to confirmation. 3. SHIPPING TERMS: EX WORKS. Unless otherwise stated in the order acknowledgement, all taxes, levies, duties, charges and expens-es payable at or after the time of delivery with respect to the goods shall be borne by the Buyer. 4. MINIMUM INVOICE: A minimum charge of 100 EUR will be made for any single order for tool parts. Orders from Distributors are only accepted if the total order value minimum is 500 EUR. 5. RISK OF LOSS AND DAMAGE: Unless otherwise stated in the order acknowledgement, delivery shall take place ex-factory from the logistics center as mentioned at the bottom of the order confirmation, at which time risk of loss shall pass to the Buyer. Upon the writ-ten request of Buyer, Seller will, without any responsibility, arrange for insurance of shipments against loss or damage in transit but in Buyer’s name and at his expense. 6. PAYMENT: Unless otherwise stated on the invoice, all payments due shall be made in EUR to Seller’s bank account. Unless otherwise agreed in writing, terms are net 30 days from invoice. Failure to pay within said period of time shall entail automatically without further notice at 2 % (two percent) increase per month on the unpaid amounts. 7. PROPERTY: The goods sold hereunder shall remain the property of Seller until paid for in full. If Buyer refuses delivery of the goods for any reason whatsoever, Seller reserves the right to store the goods in a warehouse of his choice at the risk and expense of Buyer. 8. DELIVERY: The quoted delivery times are for information only. Exceeding the delivery time by Seller does not entitle Buyer to indemnities nor to refusal of the goods unless this has been agreed by registered mail by Seller. However, Seller shall use all reasonable effort to deliver the goods within the term specified in the acknowledgement of order. No liability shall result from delay in perfor-mance or non-performance caused by circumstances beyond the control of the Seller including but not limited to acts of God, fire, flood, war, government action, strikes, inability to obtain raw materials or delays of carriers. Quantities so affected may be eliminated from the contract without liability but the contract shall remain otherwise unaffected. 9. Orders, when accepted, cannot be cancelled without our written consent. No material will be taken back without our written consent. Orders for non-standard (i.e. non-cancellable/non-returnable) material may not be cancelled nor will Victaulic accept return of such material for credit. Victaulic reserves the right to change the designation of products from stan-dard to non-standard and vice versa. This may be done at any time without notice, and without incurring obligation. For further information contact Victaulic. 10. RETURNED MATERIAL: No returns of goods shipped are accepted unless Seller has previously been informed in writing of the reason for the return and has been given the opportunity to verify the defect or deficiency claimed to exist and has agreed to the exis-tence thereof. If Seller accepts the return of goods, in writing, for any reason other than their being defective or deficient, Seller reserves the right to make a charge for transportation and refinishing and, in addition, a handling charge equal to thirty percent (30 %) of the invoice price relating to the goods so returned. 11. PRODUCT CHANGE: The right to make changes in design or materials when necessary, without prior notice, is reserved. 12. DRAWINGS: Drawings and technical data included in Seller’s quotations are for information only. They shall not be binding for construction unless certified. All such documents transmitted to Buyer remain Seller’s property. They shall not be transmitted to third parties nor copied and shall not be used in conjunction with this contract. 13. INSPECTION: Buyer’s inspectors or expeditors will only be received after appointment with Seller’s Customer Service Department. It is Seller’s policy not to accept any expediting on its vendors. In case inspection is required, goods will be invoiced two weeks after our advice “goods ready for inspection” and our invoice will be payable as per the conditions stated above from the date of issue of our invoice. 14. CHOICE OF LAW AND JURISDICTION: The validity, performance construction and effect of these terms and conditions shall be governed by Belgian Law, including the Uniform Laws on International Sale of Goods which have been ratified by Belgium. Any litigation in connection with these terms and conditions shall be decided upon by the Court of Seller’s principal place of business. Notwithstanding the foregoing, Seller may at its option bring a legal action against Buyer before the Court of the latter’s principal place of business. 15. CLAIMS: Failure to give notice in writing of claim ten (10) days from the date of receipt shall constitute a waiver by Buyer on all claims in respect of such goods.
Warranty
waRRantyWe warrant all products to be free from defects in materials and workmanship under normal conditions of use and service. Our obliga-tion under this warranty is limited to repairing or replacing at our option at our factory any product which shall within one year after delivery to original buyer be returned with transportation charges prepaid, and which our examination shall show to our satisfaction to have been defective. THIS WARRANTY IS MADE EXPRESSLY IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THE BUYER’S SOLE AND EXCLUSIVE REMEDY SHALL BE FOR THE REPAIR OR REPLACEMENT OF DEFECTIVE PRODUCTS AS PROVIDED HEREIN. THE BUYER AGREES THAT NO OTHER REMEDY (INCLUDING, BUT NOT LIMITED TO, INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR LOST PROFITS, LOST SALES, INJURY TO PERSON OR PROPERTY OR ANY OTHER INCIDENTAL OR CONSEQUENTIAL LOSS) SHALL BE AVAILABLE TO HIM. Victaulic neither assumes nor authorizes any person to assume for it any other liability in connection with the sale of such products. This warranty shall not apply to any product which has been subject to misuse, negligence or accident, which has been repaired or altered in any manner outside of Victaulic’s factory or which has been used in a manner contrary to Victaulic’s instructions or recom-mendations. Victaulic shall not be responsible for design errors due to inaccurate or incomplete information supplied by Buyer or its representatives. Items purchased by Victaulic and resold will have the original equipment manufacturer’s warranty extended to Victaulic customers.
EFFECTIVE AUGUST 4, 2008
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY . © 2010 VICTAULIC COMPANY . ALL RIGHTS RESERVED .
www .victaulic .comThe Victaulic website is an information resource that can help you with your piping projects . Among the many resources available at the site:
• Fully searchable product and project databases • Free product submittals • Free product literature • Piping software demos and modules • Information on new product innovations • Support services, and more . . .
Piping. Systems. Solutions.
uPDatED 1/2011 PL2011-FaD-Eu-EuRo 4642 REv g
VICTAULIC
BELGIUM (EUROPE HEADQUARTERS)
Prijkelstraat 36 B9810 Nazareth (Belgium) tel. +32 93 81 1500 fax +32 93 80 4438
UNITED ARAB EMIRATES
P.O. Box 17683 Jebel Ali Dubai (United Arab Emirates) tel. +971 48 838 870 fax +971 48 838 860
UNITED KINGDOM
Units B1 & B2, SG1 Industrial Park Cockerell Close Gunnels Wood Road, Stevenage Hertfordshire SG1 2NB (UK) tel. +44 (0) 143 831 0690 fax +44 (0) 143 831 0699
www.victaulic.com
SPAIN
Autovia Madrid-Barcelona KM 45,000 Avda. De Milan 1819200 Azuqueca De Henares (Spain)tel. +34 949 348 490fax +34 949 266 848
ITALY
Via M. Biagi 23/25/2727022 Casorate Primo (Italy)tel. +39 02 900 58 256fax +39 02 900 58 292
GERMANY
LOGICPARK
Gutenbergstraße 19D-64331 Weiterstadt (Germany)tel. +49 (0) 6151 9573 - 0fax +49 (0) 6151 9573 - 150
UNITED STATES (WORLD HEADQUARTERS)
P.O. Box 314901 Kesslersville RoadEaston, PA 18044-0031 (USA)tel. +1 610 559 3300fax +1 610 250 8817 CANADA
123 Newkirk RoadRichmond Hill, ON L4C 3G5 (Canada)tel. +1 905 884 7444fax +1 905 884 9774
ASIA
Unit 06-10, Floor 3AA Mansion 291 Fumin RoadShanghai 200031 (China)tel. +86 21 6170 1222fax +86 21 6170 1221