B.F.VB.F.V
T.O.W T.O.WT.O.W
CAP.=10KL.DOMESTIC
CAP.=8KL.
O.H FIRE WATER TANK
O.H
WATER TANK
TERRACE FLOOR.
BASEMENT FLOOR
GROUND FLOOR.
8th FLOOR.
7th FLOOR.
6th FLOOR.
5th FLOOR.
4th FLOOR.
2nd FLOOR.
3rd FLOOR.
1st FLOOR.
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
65Ø F.W.S80Ø D.W.S
FILLING PIPE FROM S.T.P32Ø F.W.S O.H TANK
FILLING PIPE FROM PUMP ROOM40Ø D.W.S O.H TANK
FILLING PIPE FROM S.T.P32Ø F.W.S O.H TANK
TO KITCHEN
FILLING PIPE FROM PUMP ROOM40Ø D.W.S O.H TANK
FILLING PIPE FROM S.T.P32Ø F.W.S O.H TANK
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
FLUSHING
CAP.=4KL.
O.H
WATER TANK
40Ø F.W.S50Ø D.W.S
40Ø H.W.S
FILLING PIPE FROM PUMP ROOM40Ø D.W.S O.H TANK
FILLING PIPE FROM S.T.P32Ø F.W.S O.H TANK
FILLING PIPE FROM S.T.P32Ø F.W.S O.H TANK
FILLING PIPE FROM PUMP ROOM40Ø D.W.S O.H TANK
FILLING PIPE FROM PUMP ROOM40Ø D.W.S O.H TANK FILLING PIPE FROM S.T.P32Ø F.W.S O.H TANK
* ALL VALVE 50mm DIA & ABOVE SHALL BE BUTTER FLY VALVE.
* ALL VALVE UP TO 40mm DIA SHALL BE BALL VALVE.
LEGEND FOR PLUMBINGDOMESTIC WATER SUPPLY PIPED.W.SFLUSHING WATER SUPPLY PIPEF.W.S
HOT WATER SUPPLY PIPEH.W.STOP OF WATERT.O.W
VALVE
NON-RETURN VALVE
FHCLV
FHR
DOWN-COMER PIPE CONNECTEDWITH BASEMENT RING MAIN B.
F.V
N.R.
V
2 WAY FIRE BRIGADE INLET CONNECTION
FHCLV
FHR
FHCLV
FHR
FHCLV
FHR
FHCLV
FHR
FHCLV
FHR
FHCLV
FHR
FHCLV
FHR
FHCLV
FHR
LVA.R.V
B.F.V
100Ø M.S FIRE WETRISER CUM
CUM DOWN-COMER PIPE100Ø M.S FIRE WETRISER
CUM DOWN-COMER PIPE100Ø M.S FIRE WETRISER
DOMESTIC TANK OVERFLOW PIPE65Ø FIRE WATER TANK TO
NON-RETURN VALVEN.R.V
BUTTER FLY VALVEB.F.V
DRG. TITLE
SCALE1:150DEALTHITESH
ARCHITECT:V A S T U N I D H IARCHITECT, PLANNER & INT. DESIGNERSB-135, SECTOR 44,NOIDAPHONE:2432190 FAX:4331407
PROJECT:
VILLAGE BHANKROTA, AJMER ROAD, JAIPUR
CLIENT:
208,OCEAN COMPLEX SEC-18,NOIDA
REV. NO.
DRG. NO.D'T(9)-PL-SYS-7
DATE12-03-2014
TOWER NO.
MAJESTIC PROPERTIES PVT.LTD.
WATER SUPPLY SYSTEM
TOWER NO. B&C
THIS DRAWING IS THE PROPERTY OF M/SVASTUNIDHI AND SHALL NOT BEREPRODUCED OR USED FOR ANYOTHER PURPOSE THAN SPECIFIEDWITHOUT WRITTEN PERMISSION
CHECKEDMAHENDRA
T17 ( G+8)
PRINT DATA:S.NO. DATE (PRINTS)ISSUED TO
REVISIONS:S.NO. REV.NO. PARTICULARS
NO.
NOTES:
N
LAVANYA
I-HOMES AND
DIAGRAM (PLUMBING)
KAKROLA ROAD NAJAFGARHNEW DELHI-110043PH:- [email protected]
1/30 ROSHAN GARDEN-IIARK CONSULTANTSPLUMBING CONSULTANTS