pkg pkg-pump package - deaerator...high npsh models can be fabricated in multiple stages for ease of...

2
HS Series Up to 350,000 #/hr Low Headroom PKG – Pump Package SPECIFICATION SHEET Performance Fill in and send to Kansas City Deaerator or request a detailed specification sheet. Add additional thermal cases as needed. 80 ITEM DESCRIPTION ACC PKG PUMP PKG SELECT M BFP RECIRC M1 BFP Recirc Shutoff NA OPT M2 BFP Recirc Check NA OPT M3 BFP Recirc Orifice NA OPT BFP Recirc ARC Valve NA OPT M4 BFP Recirc Piping NA OPT M5 BFP Recirc Pressure Gauge NA OPT N BFP SUCTION N1 BF Pumps (2) 100% Capacity NA STD (3) 50% Capacity NA OPT Motors ODP NA STD TEFC NA OPT N2 BFP Suction Isolation Valve NA STD N3 BFP Suction Strainer NA STD N4 BFP Suction Piping NA STD N5 BFP Suction Expansion Joint NA STD N6 BFP Discharge Pressure Gauge NA OPT N7 BFP Discharge Check Valve NA OPT N8 BFP Discharge Isolation Valve NA OPT O CHEMICAL FEED O Chemical Feed Quill OPT OPT Q OVERFLOW Q1 Overflow Valve/Trap STD STD Q3 Overflow Piping OPT STD R LEVEL SWITCH R1 Level Switches High & Low (TWO) STD STD High High (ADDITIONAL) OPT OPT R2 Level Switch Bridle Piping OPT STD S GAUGE GLASS S1 Gauge Glass Red Line Pyrex STD STD Reflex OPT OPT Magnetic OPT OPT S2 Gauge Glass Bridle OPT STD ITEM DESCRIPTION ACC PKG PUMP PKG SELECT A WATER INLET A1 Inlet Valve Mechanical STD STD Pneumatic OPT OPT A2 Level Controller STD STD Level Transmitter OPT OPT A3 Inlet Valve Bypass Valves OPT STD A4 Inlet Valve Bypass Piping OPT STD A5 Inlet Valve Bypass Strainer OPT STD B STEAM CONTROL B1 Steam PRV OPT Self Contained OPT OPT Pneumatic OPT OPT B2 Steam PRV Controller OPT OPT B3 Steam PRV Bypass Valves OPT OPT B4 Steam PRV Bypass Piping OPT OPT B5 Steam PRV Bypass Strainer OPT OPT C RELIEF VALVE C1 Relief Valve Sentinel STD STD Full OPT OPT C2 Relief Valve Exhaust Piping OPT OPT D THERMOMETER D1 (2) 5" Thermometer w/ss wells STD STD E PRESSURE GUAGE E1 (1) 4 1/2" Pressure Gauge STD STD E2 Siphon & Cock STD STD E3 Pressure Transmitter OPT OPT F VENT F1 Vent Valve STD STD F2 Vent Orifice w/Flange OPT OPT F3 Vent Bypass Valves OPT OPT F4 Vent Bypass Piping OPT OPT H VACUUM BREAKER H1 Vacuum Breaker STD STD PKG – Pump Package Standard Deaerating Units K K A A N N S S A A S S C C I I T T Y Y D D E E A A E E R R A A T T O O R R Kansas City Deaerator’s Pump Package System can be provided with any model deaerator. Standard Pump Packages are available with optional special design packages and available in any configuration. Standard packages include vertical centrifugal pumps. PKG-Pump Package Pump Package Principles of Operation Standard flows up to 331 GPM,165,000 #/HR per pump Standard pump discharge pressure up to 750 feet Continuous operation pumps with recirculation lines Control panel with pump start- stop station Optional: a. Triplex Pumps b. Pump Starters FEATURES Kansas City Deaerator Company 6731 West 121 st Street, Overland Park, KS 66209 Tel (913) 338-2111 Fax (913) 338-2144 Website: www.deaerator.com Email: [email protected] OPERATING CONDITIONS Operating Pressure FEEDWATER INLET % Makeup MU Temperature %Condensate Cond. Temperature STORAGE CAPACITY Minutes at Overflow Gallon at Overflow Accessories Select package or individual items TC Series Up to 250,000 #/hr Tray Unit Meets HEI BDS Series Up to 250,000 #/hr Tray Unit Meets HEI DS Series Up to 800,000 #/hr Tray Unit Meets HEI VS & VT Series Up to 800,000 #/hr Tray Unit Minimal Plan Area Meets HEI HH Series Up to 16,000,000 #/hr Tray Unit-Meets HEI SPECIAL REQUIREMENTS Post Weld Heat Treatment Minimum Radiography WFMP Testing HEI BF PUMPS Quantity Capacity TDH PROJECT DEAERATOR Quantity Capacity DESIGN ASME SEC. VIII, DIV.1 Design Pressure Full Vacuum Design Design Temperature Corrosion Allowance Copyright © January 2004

Upload: others

Post on 19-Mar-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PKG PKG-Pump Package - Deaerator...High NPSH models can be fabricated in multiple stages for ease of shipping and quick assembly. Complete packaged, skid-mounted deaerator for a paperboard

HS

Serie

s U

p to

350

,000

#/h

r Lo

w H

eadr

oom

PKG –

Pum

p Pac

kage

S

PECI

FICAT

ION S

HEET

P

erfo

rman

ce –

Fi

ll in

and

sen

d to

Kan

sas

City

Dea

erat

or o

r req

uest

a d

etai

led

spec

ifica

tion

shee

t. A

dd a

dditi

onal

ther

mal

cas

es a

s ne

eded

.

80

ITEM

D

ESC

RIP

TIO

N

ACC

PKG

PUMP

PK

G √

SE

LECT

M

B

FP R

ECIR

C

M

1 B

FP R

ecirc

Shu

toff

NA

O

PT

M

2 B

FP R

ecirc

Che

ck

NA

O

PT

M

3 B

FP R

ecirc

Orif

ice

NA

O

PT

BFP

Rec

irc A

RC

Val

ve

NA

O

PT

M

4 B

FP R

ecirc

Pip

ing

NA

O

PT

M

5 B

FP R

ecirc

Pre

ssur

e G

auge

N

A

OP

T

N

BFP

SU

CTI

ON

N1

BF

Pum

ps

(2

) 100

% C

apac

ity

NA

S

TD

(3

) 50%

Cap

acity

N

A

OP

T

M

otor

s

OD

P N

A

STD

TEFC

N

A

OP

T

N2

BFP

Suc

tion

Isol

atio

n Va

lve

NA

S

TD

N

3 B

FP S

uctio

n St

rain

er

NA

S

TD

N

4 B

FP S

uctio

n Pi

ping

N

A

STD

N5

BFP

Suc

tion

Expa

nsio

n Jo

int

NA

S

TD

N6

BFP

Dis

char

ge P

ress

ure

Gau

ge

NA

O

PT

N

7 B

FP D

isch

arge

Che

ck V

alve

N

A

OP

T

N8

BFP

Dis

char

ge Is

olat

ion

Valv

e N

A

OP

T

O

CH

EMIC

AL

FEED

O

Che

mic

al F

eed

Qui

ll O

PT

O

PT

Q

O

VER

FLO

W

Q

1 O

verf

low

Val

ve/T

rap

STD

S

TD

Q

3 O

verf

low

Pip

ing

OP

T S

TD

R

LEVE

L SW

ITC

H

R

1 Le

vel S

witc

hes

H

igh

& L

ow (T

WO

) S

TD

STD

Hig

h H

igh

(AD

DIT

ION

AL)

O

PT

OP

T

R2

Leve

l Sw

itch

Brid

le P

ipin

g O

PT

STD

S G

AU

GE

GLA

SS

S1

G

auge

Gla

ss

R

ed L

ine

Pyre

x S

TD

STD

Ref

lex

OP

T O

PT

M

agne

tic

OP

T O

PT

S2

G

auge

Gla

ss B

ridle

O

PT

STD

ITEM

D

ESC

RIP

TIO

N

ACC

PKG

PUMP

PK

G √

SE

LECT

A

W

ATE

R IN

LET

A1

Inle

t Val

ve

M

echa

nica

l S

TD

STD

Pneu

mat

ic

OP

T O

PT

A

2 Le

vel C

ontr

olle

r S

TD

STD

Le

vel T

rans

mitt

er

OP

T O

PT

A

3 In

let V

alve

Byp

ass

Valv

es

OP

T S

TD

A

4 In

let V

alve

Byp

ass

Pipi

ng

OP

T S

TD

A

5 In

let V

alve

Byp

ass

Stra

iner

O

PT

STD

B

STEA

M C

ON

TRO

L

B1

Stea

m P

RV

O

PT

Se

lf C

onta

ined

O

PT

OP

T

Pneu

mat

ic

OP

T O

PT

B

2 St

eam

PR

V C

ontr

olle

r O

PT

OP

T

B3

Stea

m P

RV

Byp

ass

Valv

es

OP

T O

PT

B

4 St

eam

PR

V B

ypas

s Pi

ping

O

PT

OP

T

B5

Stea

m P

RV

Byp

ass

Stra

iner

O

PT

OP

T

C

REL

IEF

VALV

E

C1

Rel

ief V

alve

Sent

inel

S

TD

STD

Full

OP

T O

PT

C

2 R

elie

f Val

ve E

xhau

st P

ipin

g O

PT

OP

T

D

THER

MO

MET

ER

D

1 (2

) 5"

Ther

mom

eter

w/s

s w

ells

S

TD

STD

E PR

ESSU

RE

GU

AG

E

E1

(1) 4

1/2

" Pr

essu

re G

auge

S

TD

STD

E2

Siph

on &

Coc

k S

TD

STD

E3

Pres

sure

Tra

nsm

itter

O

PT

OP

T

F VE

NT

F1

Ve

nt V

alve

S

TD

STD

F2

Vent

Orif

ice

w/F

lang

e O

PT

OP

T

F3

Vent

Byp

ass

Valv

es

OP

T O

PT

F4

Ve

nt B

ypas

s Pi

ping

O

PT

OP

T

H

VAC

UU

M B

REA

KER

H1

Vacu

um B

reak

er

STD

S

TD

PKG

–Pu

mp

Pack

age

Stan

dard

D

eaer

atin

g U

nits

KK AA

NN SSAA SS

CCII TT

YY DDEE AA

EE RRAA TT

OO RR

K

ansa

s C

ity D

eaer

ator

’s P

ump

Pac

kage

Sys

tem

can

be

prov

ided

w

ith a

ny m

odel

dea

erat

or.

Sta

ndar

d P

ump

Pac

kage

s ar

e av

aila

ble

with

op

tiona

l sp

ecia

l de

sign

pac

kage

s an

d av

aila

ble

in a

ny c

onfig

urat

ion.

S

tand

ard

pack

ages

incl

ude

verti

cal c

entri

fuga

l pum

ps.

PKG-

Pum

p Pac

kage

Pu

mp

Pack

age

Prin

cipl

es o

f Ope

ratio

n

Sta

ndar

d flo

ws

up to

331

GP

M,1

65,0

00 #

/HR

per

pum

p

Sta

ndar

d pu

mp

disc

harg

e

pres

sure

up

to 7

50 fe

et

C

ontin

uous

ope

ratio

n pu

mps

with

reci

rcul

atio

n lin

es

Con

trol p

anel

with

pum

p st

art-

stop

sta

tion

O

ptio

nal:

a.

Trip

lex

Pum

ps

b.

Pum

p S

tarte

rs

FEA

TUR

ES

1

Kan

sas

City

Dea

erat

or C

ompa

ny

6

731

Wes

t 121

st S

treet

, Ove

rland

Par

k, K

S 6

6209

Tel

(913

) 338

-211

1 F

ax (9

13) 3

38-2

144

W

ebsi

te: w

ww

.dea

erat

or.c

om E

mai

l: in

fo@

deae

rato

r.com

OPE

RATI

NG C

ONDI

TION

S

Ope

ratin

g Pre

ssur

e

FEED

WAT

ER IN

LET

%

Mak

eup

M

U Te

mper

ature

%Co

nden

sate

C

ond.

Temp

eratu

re

ST

ORAG

E CA

PACI

TY

M

inutes

at O

verflo

w

Gall

on at

Ove

rflow

Acc

esso

ries

– S

elec

t pac

kage

or i

ndiv

idua

l ite

ms

TC S

erie

s

Up

to 2

50,0

00 #

/hr

Tray

Uni

t M

eets

HE

I

BD

S Se

ries

Up

to 2

50,0

00 #

/hr

Tray

Uni

t M

eets

HE

I

DS

Serie

s U

p to

800

,000

#/h

r Tr

ay U

nit

Mee

ts H

EI

VS &

VT

Serie

s U

p to

800

,000

#/h

r Tr

ay U

nit

Min

imal

Pla

n A

rea

Mee

ts H

EI

HH

Ser

ies

Up

to 1

6,00

0,00

0 #/

hr

Tray

Uni

t-Mee

ts H

EI

SPEC

IAL

REQU

IREM

ENTS

Pos

t Weld

Hea

t Tre

atmen

t

Mini

mum

Radio

grap

hy

W

FMP

Testi

ng

H

EI

BF

PUM

PS

Q

uanti

ty

Cap

acity

TDH

PROJ

ECT

DE

AERA

TOR

Q

uanti

ty

Cap

acity

DESI

GN

A

SME

SEC.

VIII,

DIV

.1

Des

ign P

ress

ure

F

ull V

acuu

m De

sign

D

esign

Tem

pera

ture

C

orro

sion A

llowa

nce

Cop

yrig

ht ©

Jan

uary

200

4

Page 2: PKG PKG-Pump Package - Deaerator...High NPSH models can be fabricated in multiple stages for ease of shipping and quick assembly. Complete packaged, skid-mounted deaerator for a paperboard

HS=

Hor

izon

tal S

pray

(S

ee fr

ont c

over

for a

dditi

onal

serie

s)

400

6 =

Size

from

Cha

rt

(577

HP

20,0

00#/

HR

) (S

elec

t acc

ordi

ng to

requ

ired c

apac

ity)

018

=18,

000

#/H

R

(Use

actu

al ca

paci

ty, c

harts

show

max

imum

capa

city)

M

=Mec

hani

cal

or P

=Pne

umat

ic

(Lea

ve bl

ank f

or no

ne)

P=P

ipin

g In

clud

ed

O=P

ipin

g N

ot In

clud

ed

PK

G=P

acka

ge

(Lea

ve bl

ank f

or no

ne)

2 =

# o

f Pum

ps

040

= F

low

(GPM

) 1

50 =

Hea

d (P

SI)

PKG –

Pum

p Pac

kage

M

ODEL

S

SER

IES

S

IZE

CA

PACI

TY

TYPE

PI

PED

#/P

UMPS

FL

OW

HE

AD

PKG –

Pum

p Pac

kage

CHAR

TMo

del N

umbe

r Sel

ectio

n

Ser

ies

Size

C

apac

ity

T

ype

P

ipin

g

P

KG #

/ Pum

ps

Flow

H

ead

D

EAER

ATO

R

AC

CES

SOR

IES

S

TAN

D &

PU

MP/

PAC

KA

GE

EXAM

PLE:

H S

4 0

0 6

--

0 1

8 -

-

M

--

0

P K

G -

- 2

--

0 4

0 -

- 1

5 0

_

_

_ _

_ _

_

_ _

_

_

_ _

_

_

_ _

_

_

_ _

Typi

cal A

rrang

emen

t

H

igh

NPS

H m

odel

s ca

n be

fabr

icat

ed in

mul

tiple

st

ages

for e

ase

of s

hipp

ing

and

quic

k as

sem

bly.

C

ompl

ete

pack

aged

, ski

d-m

ount

ed

deae

rato

r for

a p

aper

boar

d pr

oduc

er.

D

eaer

ator

shi

pped

sep

arat

e fr

om p

ump

pack

age

to

mee

t shi

ppin

g cl

eara

nce.