pixel mechanical

13
1 PIXEL Mechanical H. Wieman face to face Integration 15-May-2008

Upload: quin-ortega

Post on 03-Jan-2016

19 views

Category:

Documents


3 download

DESCRIPTION

PIXEL Mechanical. H. Wieman face to face Integration 15-May-2008. topics. Introduction – mechanical design Pixel specifications and parameters Review insertion mechanics Kinematic mounts air flow analysis cooling air requirements. Pixel geometry. End view. 8 cm radius. 20 cm. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: PIXEL Mechanical

1

PIXEL Mechanical

H. Wiemanface to face Integration15-May-2008

Page 2: PIXEL Mechanical

2

topics

Introduction – mechanical design Pixel specifications and parameters Review insertion mechanics

Kinematic mounts air flow analysis

cooling air requirements

Page 3: PIXEL Mechanical

3

Pixel geometry

2.5 cm radius

8 cm radius

Inner layer

Outer layer

End view

One of two half cylinders

20 cm

coverage +-1

total 40 ladders

Page 4: PIXEL Mechanical

4

Some pixel features and specifications

Pointing resolution (13 19GeV/pc) m

Layers Layer 1 at 2.5 cm radiusLayer 2 at 8 cm radius

Pixel size 18.4 m X 18.4 m

Hit resolution 10 m rms

Position stability 6 m (20 m envelope)

Radiation thickness per layer

X/X0 = 0.28%

Number of pixels 436 M

Integration time (affects pileup) 0.2 ms

Radiation tolerance 300 kRad

Rapid installation and replacement to cover rad damage and other detector failure

Installation and reproducible positioning in a shift

criticalanddifficult

(ATLAS Pixels 1.2%)

Page 5: PIXEL Mechanical

5

New details on kinematic mounts

Page 6: PIXEL Mechanical

6

Pixel kinematic mounts

Page 7: PIXEL Mechanical

7

Pixel kinematic mounts

Page 8: PIXEL Mechanical

8

Pixel kinematic mounts

Page 9: PIXEL Mechanical

9

Pixel kinematic mounts

Page 10: PIXEL Mechanical

10

Pixel kinematic mounts

Page 11: PIXEL Mechanical

11

preliminary air flow study

ANSYS CFX FEE Flow analysis simplified geometry to limit

mesh input velocity 8 m/s down

module support tube ISC blank off to force return

flow over silicon surfaces Result:

good flow velocity over both inner and outer silicon

Page 12: PIXEL Mechanical

12

Pixel air cooling system

Internal duct 2 in diameter X 5 ft

Internal duct 2 in diameter X 5 ft

external duct 6 in diameter X 50 ft

external duct 6 in diameter X 50 ft

chiller

pump

Wide angle hall ISC

Air flow: 400 SCFM

Total pressure drop: 22 inches water

Temperature: 75 deg F/34 deg C or maybe -10 deg C

Page 13: PIXEL Mechanical

13

Pixel heat load break down

Heat source Power (watts)

detector silicon 160

on ladder signal drivers 80

voltage regulators in ISC 24

heat influx through ducting and ISC if 35 deg C below ambient

600 - 2000

pumping 1000

Total load on chiller 1900 - 3300