PISTON ACCUMULATOR INSTALLATION AND OPERATION MANUAL Revision no. 2013-02

Upload: lykhuong

Post on 30-Jan-2018

215 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: PISTON ACCUMULATOR INSTALLATION AND OPERATION MANUAL · PDF filemanual form attached in this document to monitor the accumulator’s ... checked with the aid of the liquid side

PISTON ACCUMULATOR

INSTALLATION AND OPERATION MANUAL

Revision no. 2013-02

Page 2: PISTON ACCUMULATOR INSTALLATION AND OPERATION MANUAL · PDF filemanual form attached in this document to monitor the accumulator’s ... checked with the aid of the liquid side

www.hydroll.com Copyright © Hydroll. All rights reserved. INSTALLATION AND OPERATION MANUAL | 2/15

Table of contents

1 Introduction 3

2 Safety 4

3 Warranty 5

4 Technical specifications and labels 6

5 General illustration of the accumulator structure 7

6 Installation 8

7 Maintenance 9

8 Calculated service life - Dynamic load 10

9 Storage 11

10 Transportation 11

11 Withdrawal from service and disposal 12

12 Practical advices for user 13

13 Monitoring pre-charge pressure 14

Symbols used in the operating instructions

Additional information

Important points that require attention

Points that require caution

Page 3: PISTON ACCUMULATOR INSTALLATION AND OPERATION MANUAL · PDF filemanual form attached in this document to monitor the accumulator’s ... checked with the aid of the liquid side

1 Introduction

EN 14359 standard defines the device described

in this manual as follows: A gas pressurised accu-

mulator for hydraulic applications. Subsequently,

the device is simply referred to as the ‘accumulator’.

The accumulator is designed, manufactured and

tested according to the PED(97/23/EC) guidelines.

Hydroll accumulators also covers SELO Pressure

Vessels A1 certificate as well as ASME for under

6” or 152mm internal diameter

When the instructions of this manual and the limit values for the accumulator are

followed, the operation is safe and accumulator will remain functional throughout

the planned lifecycle. The accumulator is safe and reliable to use when it is serviced

according to the instructions specified in this manual. To avoid injuries and damage

to the devices, it is important to read through these instructions before installation

of the accumulator in a hydraulic system.

Hydroll Oy reserves the right to make changes to its products without prior notice.

The information provided in this instruction manual is valid at the time of its

publication. The manufacturer will not be liable for direct or indirect injuries or

material damages if the instructions provided below are not complied with.

www.hydroll.com Copyright © Hydroll. All rights reserved. INSTALLATION AND OPERATION MANUAL | 3/15

Page 4: PISTON ACCUMULATOR INSTALLATION AND OPERATION MANUAL · PDF filemanual form attached in this document to monitor the accumulator’s ... checked with the aid of the liquid side

2 Safety

Hydraulic accumulators are pressure vessels and must be treated accordingly. Only

trained and qualified individuals should perform installation and maintenance procedures

on the accumulators. Following safety instruction must always be followed.

Only use nitrogen (N2) as a charging gas. Never use air or oxygen for

charging (this may lead to an explosion).

Never loosen the gas valve if the accumulator is pressurised.

Never disassemble a pressurised accumulator. The energy of

pressurised accumulators may discharge suddenly. Contact your dealer

or manufacturer in case of failure and for maintenance procedures.

The accumulator structure and operation may not be modified

in any ways.

Always consider accumulator contain pressure until proven otherwise.

Always wear safety glasses, and chemical resistant protective

gloves, if needed.

www.hydroll.com Copyright © Hydroll. All rights reserved. INSTALLATION AND OPERATION MANUAL | 4/15

Page 5: PISTON ACCUMULATOR INSTALLATION AND OPERATION MANUAL · PDF filemanual form attached in this document to monitor the accumulator’s ... checked with the aid of the liquid side

3 Warranty

Hydroll provides a one-year material guarantee on its accumulators provided that the

instructions for installation and operation are followed and the acceptable accumulator

limit values have not been exceeded. The guarantee does not cover normal wear during

the use of the accumulator. In case of failure of the accumulator during the warranty

period contact to Hydroll personnel. Hydroll is not responsible of changes of any kind

made to accumulator design.

Limitation of the liablity

Only trained and qualified individuals should perform installation and maintenance

on the accumulators. Manufacturer’s installation and maintenance instructions must

always be followed in combination with local working and safety procedures and

guidelines. Hydroll is not in responsible of direct or indirect damages that have been

caused by accumulator misuse, mishandling or faulty installation by not following the

manufacturer’s instructions. Neither is the manufacturer responsible of the direct or

indirect damages caused by neglecting of the local working and safety instruction.

www.hydroll.com Copyright © Hydroll. All rights reserved. INSTALLATION AND OPERATION MANUAL | 5/15

Page 6: PISTON ACCUMULATOR INSTALLATION AND OPERATION MANUAL · PDF filemanual form attached in this document to monitor the accumulator’s ... checked with the aid of the liquid side

4 Technical specifications and labels

These instructions apply to the accumulator sizes ID 50 to 250 mm, with a pressure area

between 250 and 650 bars depending on the accumulator model and a capacity between

0.1 to 100 litres.

Hydroll piston pressure accumulator product groups:

The HPS series includes single piston pressure accumulators.

The HPD series includes dual piston pressure accumulators.

The HDC series includes dual piston and dual mode pressure accumulators.

The accumulator type plate contains the following information:

www.hydroll.com Copyright © Hydroll. All rights reserved. INSTALLATION AND OPERATION MANUAL | 6/15

▪ Hydroll Oy contact details

▪ Serial and lot numbers

▪ Date of manufacture

▪ Type consisting of the accumulator

series, the design pressure and the

sheath inner diameter values

▪ UN number and class

▪ Design pressure

▪ Temperature area

▪ Capacity

▪ Test pressure

▪ Date of proof test

▪ Gas pre-charge pressure

▪ Device warnings

▪ Compliance markings (CE, SELO…)

▪ Test oil cleanliness level

Examples of the product labels

Page 7: PISTON ACCUMULATOR INSTALLATION AND OPERATION MANUAL · PDF filemanual form attached in this document to monitor the accumulator’s ... checked with the aid of the liquid side

5 General illustration of the accumulator structure

Figure 1. HPS10 ø 80 structural image

www.hydroll.com Copyright © Hydroll. All rights reserved. INSTALLATION AND OPERATION MANUAL | 7/15

InnerDiameterID

FluidPort(egG1/2)

OuterDiameterOD

30mm

LengthL

Parts List

Part No. Part Pcs

1 Cylinder Tube 1

2 Gas End-Flange 1

3 Fluid End-Flange 1

4 Piston 1

5 Valve 1

6 Protection Cap 1

7 Support Ring 2

8 O-Ring 2

9 Piston Seal 1

10 Guide Ring 2

Page 8: PISTON ACCUMULATOR INSTALLATION AND OPERATION MANUAL · PDF filemanual form attached in this document to monitor the accumulator’s ... checked with the aid of the liquid side

6 Installation

Following table provides step by step procedure for the accumulator installation.

1. Visually inspect the accumulator for damage.

2. Handle the accumulator with care to avoid damaging the paintwork. Damage

to the paintwork may expose the device to corrosion. Paint damages must

be repaired immediately with 2-component polyurethane paint.

3. Check the capacity and the design pressure of the accumulator on its type

plate. Ensure that the indicated temperature range is appropriate for the

prevailing conditions. Never exceed the design pressure.

4. Ensure the cleanliness of the hydraulic system that will be connected to

the accumulator. The accumulator manufacturer’s guarantee will be void

if the contaminants in the system enter the accumulator and damage it.

5. Where possible, install the accumulator in an upright position with

the gas side upwards. This will ensure the longest possible service life.

Other positions are also allowed since the piston pressure accumulator

construction will be functional regardless of the position.

6. Attach the accumulator with the brackets provided by the manufacturer

as illustrated in Figure 2.

7. Measure the pre-charge within one month after the installation.

Damagedaccumulatorshouldnotbeconnectedtothesystem.

Figure 2. Recommended bracket positions

10-70mm

Note: The torque of the binding bolt between the bracket and the accumulator

▪ M10thread¨20Nm▪ M12thread¨30Nm

www.hydroll.com Copyright © Hydroll. All rights reserved. INSTALLATION AND OPERATION MANUAL | 8/15

Page 9: PISTON ACCUMULATOR INSTALLATION AND OPERATION MANUAL · PDF filemanual form attached in this document to monitor the accumulator’s ... checked with the aid of the liquid side

7 Maintenance

Check the pre-charge pressure at minimum once a year and write the result on the

manual form attached in this document to monitor the accumulator’s condition. Where

necessary, add nitrogen gas (N2) to the accumulator. Detailed instructions for N2 filling

printed in Hydroll accumulator charging kit cover. After inspection the pre-charge

ensure the gas valve functionality by adding soap water in the top of the valve to detect

potential leakages.

Please note that temperature will have an effect on the nitrogen pressure.

The manufacturer will indicate the pre-charge pressure (Po) at +20°C. The

pressure change will comply with formula P=Po*(T+273)/293.

▪ NOTE: The gas pre-charge pressure inspection interval will be

affected by the maximum operating pressure, the extent and speed

of pressure fluctuation, and the frequency of extreme operating

temperatures.

▪ If the operation of the accumulator is unsatisfactory, check the

pressure and add gas where necessary. If the pressure is discharged

from the accumulator after recharging, contact your dealer or

manufacturer.

▪ Ensure the hydraulic system oil contains no contaminants and

change the oil and filter according to the device manufacturer’s

instructions.

▪ Clean the accumulator’s outer surfaces and ensure that the paintwork

is intact when checking the pre-charge pressure. Cleaning helps

prevent corrosion. Damages to the paintwork should be repaired

immediately, since the accumulator structure does not allow for

corrosion. Repair the paintwork with two-component polyurethane

paint.

▪ Check the torque of the accumulator bracket bots during the

periodical maintenance.

▪ Only use the manufacturer’s original spare parts. Contact the

manufacturer when necessary.

www.hydroll.com Copyright © Hydroll. All rights reserved. INSTALLATION AND OPERATION MANUAL | 9/15

Page 10: PISTON ACCUMULATOR INSTALLATION AND OPERATION MANUAL · PDF filemanual form attached in this document to monitor the accumulator’s ... checked with the aid of the liquid side

The accumulator ( exluding HPS14 model) is designed to be serviced by

removing the threaded ends. When removing or attaching the liquid joint or

the gas valve, please note that the end should be prevented from rotating,

for instance by using a spanner wrench illustrated below. Tools are supplied

by Hydroll Oy.

The liquid joint torque with rubber steel sealing:

▪ Rp ¼” 30 Nm; Rp 3/8” 45 Nm

▪ Rp ½” 65 Nm; Rp ¾” 90 Nm

▪ Rp 1” 150 Nm; Rp 1 ¼” 240 Nm

▪ Rp 1 ½” 290 Nm

Figure 3. Spanner wrench

8 Calculated life time - Dynamic load

Theoretical accumulator fatigue based on EN 13345-3 standard. The graph below

illustrates the worst case scenario for structure fatigue.

NOTE: Practical fatigue curve is application dependent however pressure variation

being the main factor that influences on the shape and location of the curve.

www.hydroll.com Copyright © Hydroll. All rights reserved. INSTALLATION AND OPERATION MANUAL | 10/15

DynamicloadΔP/Pmax

Cycles/1000

FatiqueboarderlineUnlimitedzoneline

Cycleamountunlimited

Page 11: PISTON ACCUMULATOR INSTALLATION AND OPERATION MANUAL · PDF filemanual form attached in this document to monitor the accumulator’s ... checked with the aid of the liquid side

9 Storage

The accumulator should be stored in a dry and cool spot with a constant temperature.

All accumulator joints should be plugged. The accumulator should not be exposed to

excessive heat (i.e. temperatures over 40°C for long periods of time). If the accumulator

is stored for more than six months, the pre-charge pressure should be checked taking

the ambient temperature correction into account. Handle the accumulator with care.

Use approved lifting devices to lift and move the accumulator.

Take particular care not to damage the charging valve.

10 Transportation

Pressurised Hydropneumatic Piston Accumulators are considered as dangerous goods

UN 3164, Articles, Pressurized, Pneumatic, 2.2 when the accumulator is pre-charged

with compressed nitrogen on Road, Railway, Sea and Air. For this reason the shipping

company should have qualified personnel to handle the shipments and packaging of

accumulators. EU legistation requires that at least one person has been educated for

shipping dangerous goods in the company (ADR / RID-, IMDG- and IATA-regulations)

Unpressurised accumulator is not considered as dangerous goods UN 3164 and may

also be transported as standard air freight.

Valid documentation and instruction for transportation and packaging are downloadable

in Hydroll www-site: www.hydroll.com

Navigate: Downloads -> Technical Documentation -> Transportation Documentation

www.hydroll.com Copyright © Hydroll. All rights reserved. INSTALLATION AND OPERATION MANUAL | 11/15

Page 12: PISTON ACCUMULATOR INSTALLATION AND OPERATION MANUAL · PDF filemanual form attached in this document to monitor the accumulator’s ... checked with the aid of the liquid side

11 Withdrawal from service and disposal

1. A pressurised accumulator must not be discarded; the pressure should be

discharged before disposal.

2. The pressure can be discharged by using a Hydroll charging device or a connector

compatible with the valve.

3. Once the pressure has been discharged and the gas valve has been removed, the

accumulator may be handed over to metal recycling.

www.hydroll.com Copyright © Hydroll. All rights reserved. INSTALLATION AND OPERATION MANUAL | 12/15

Page 13: PISTON ACCUMULATOR INSTALLATION AND OPERATION MANUAL · PDF filemanual form attached in this document to monitor the accumulator’s ... checked with the aid of the liquid side

12 Practical advices for user

▪ Soapy water may be used to locate gas leakages. Its use is also recommended to

ensure valve performance after pressure checks.

▪ Pre-charge pressure may be checked with the aid of the liquid side pressure

measurement: the system is pressurised to exceed the accumulator’s pre-charge

pressure, and the system pressure is discharged by limiting the outflow in order

for the pressure to decrease slowly (~5 bars/min). Once the system pressure has

reached the accumulator’s pre-charge pressure, the system pressure decreases

rapidly.

Recommendation for system equipment:

▪ Pressure relief valve, the opening pressure should be lower than

the maximum allowed charger pressure retaining valve between the

charger and the pump

▪ Stopcock to allow the isolation of the charger from the system

▪ The figure below depicts normal wear and the resulting leakage in

relation to time

www.hydroll.com Copyright © Hydroll. All rights reserved. INSTALLATION AND OPERATION MANUAL | 13/15

Page 14: PISTON ACCUMULATOR INSTALLATION AND OPERATION MANUAL · PDF filemanual form attached in this document to monitor the accumulator’s ... checked with the aid of the liquid side

13 Monitoring pre-charge pressure

Accumulator serial number Pressure Date Inspector

Notes:

www.hydroll.com Copyright © Hydroll. All rights reserved. INSTALLATION AND OPERATION MANUAL | 14/15

Page 15: PISTON ACCUMULATOR INSTALLATION AND OPERATION MANUAL · PDF filemanual form attached in this document to monitor the accumulator’s ... checked with the aid of the liquid side

Hydroll OyPL 12, Lohkarekuja 6, FIN-62101 Lapua, FINLANDtel. +358 (0)20 765 7900 • fax +358 (0)20 765 7901www.hydroll.com • [email protected]

PISTON ACCUMULATOR

INSTALLATION AND OPERATION MANUALRevision no. 2013-02