PIPE & MECHANICAL INSULATION
SSL II® with ASJ Max & No Wrap Fiberglas™ Pipe Insulation
VaporWick® Pipe Insulation
FOAMULAR® XPS Pipe Insulation
Fiberglas™ Pipe & Tank Insulation
Flexwrap® Fiberglas™ Insulation
UtiliCore® Fiberglas™ Insulation
700 Series Fiberglas™ Insulation
Insul-Quick® Fiberglas™ Insulation
Fiberglas™ SCR Insulation
Fiberglas™ TIW Insulation
SoftR® Duct Wrap
2
No matter your pipe and mechanical insulation needs, we've got you covered
SSL II® with ASJ Max Fiberglas™ Pipe Insulation• Durable, cleanable ASJ Max jacket• SSL II® positive closure system• Maximum operating temperature 1,000° F
SoftR® Duct Wrap• Condensation control• Enhanced comfort control• Flexible and easy to install
700 Series Fiberglas™ Insulation• Flexible, semi-rigid or rigid boards for acoustic
and thermal insulation• Variety of density, thickness and facing
options to match your job needs
• Easy to handle, fabricate and install
UtiliCore® Fiberglas™ Insulation• Lightweight core insulation for removable/
reusable covers• Flexibility to conform to unconventional
surfaces and shapes• Easy fabrication, assembly and installation
3
TABLE OF CONTENTS
Owens Corning has a long history of helping solve the day-to-day problems of insulating pipes and equipment. That history of reliability continues as we complement our proven, effective insulation with new manufacturing processes and technologies.
8-11
FOAMULAR® XPS Pipe Insulation
VaporWick® Pipe Insulation
SSL II® with ASJ Max & No Wrap Fiberglas™
Pipe Insulation
12-14
Fiberglas™ Pipe and Tank Insulation
4-7 15-17
700 Series Fiberglas™ Insulation
UtiliCore® Fiberglas™ Insulation
Flexwrap® Fiberglas™ Insulation
24-28
Insul-Quick® Fiberglas™ Insulation
29-31
SoftR® Duct Wrap
Fiberglas™ TIW Insulation
Fiberglas™ SCR Insulation
32-33 34-36 37-39
21-2318-20
4 SSL II ® with ASJ Max and No Wrap Fiberglas™ Pipe Insulation
Fiberglas™ Pipe Insulation is a cost-effective solution for hot, cold, concealed and exposed piping in commercial and industrial buildings.
DESCRIPTIONSSL II® with ASJ Max and No Wrap Pipe Insulation products are one-piece, 36" (914mm) long hinged sections of Fiberglas™ Pipe Insulation that are opened, placed over the pipe and secured in place. They are molded from heavy-density, resin-bonded, inorganic glass fibers.
APPLICATION/USEUse to insulate pipes with operating temperatures between 0°F (-18°C) and 1,000°F (538°C) (with heat-up schedule).
• Commercial buildings
• Industrial facilities
SSL II® with ASJ Max & No Wrap Fiberglas™ Pipe Insulation
FEATURES & BENEFITSSSL II® positive closure system
• Developed specifically to work with the ASJ Max jacket to provide a tight, reliable seal without glue or staples
• Finger Lift Edge (FLE) allows for easy removal of the release liner
• Matching butt strips
ASJ Max jacket
• Durable, cleanable ASJ Max jacket
• Resists/sheds water when exposed to intermittent, short-duration precipitation during construction
• Less wicking and curling than standard ASJ
• Accepts paint and mastic as well as standard ASJ
• Higher puncture resistance than standard ASJ
• Has a finished appearance that is compatible with standard ASJ
Most sizes 3" and smaller fit over press
fittings without filleting
Maximum operating
temperature 1,000°F
ASJ Max polymer film exterior surface
Doesn’t support mold or mildew
growth1
SSL II® positive closure system seals
without glue or staples
• Process or power plants
• Hi-rise residential buildings
1. ASJ Max jacket does not support mold growth when tested in accordance with ASTM C1338
* SSL II® positive closure system available on most pipe sizes
5SSL II ® with ASJ Max and No Wrap Fiberglas™ Pipe Insulation
SSL II® with ASJ Max installation instructions1. Ambient application temperatures are from 25°F
(-4°C) to 110°F (43°C).
2. To open the hinged insulation section, pull the lap with the release strip from the jacket.
3. Open the hinged sections and place the insulation over the pipe, taking care not to get dirt, dust or moisture on the overlap area. While preparing to close the insulation, take care not to allow the adhesive on the jacket to contact anything until the insulation is properly lined up and closed over the pipe.
4. Pull the release strip from the jacket lap. Start by pulling the lap down at the middle until the adhesive touches the adhesive strip on the jacket. Press together. Rub firmly with nylon sealing tool or squeegee from the middle of the section towards the end until the lap is securely adhered to the jacket.
5. Apply the matching butt strip centered over the adjoining pipe sections, and rub with firm pressure to complete the positive closure.
6. If the operating temperature of the system is above 100°F (37°C), it is recommend that if the pipe insulation terminates with an exposed end, apply mastic over the exposed end, per the mastic manufacturer’s instructions.
Physical property data
Property Value Test Method
Density (size dependent) 3.5 to 5.5 pcf ASTM C302
Operating Temperature Range2 0° to 1,000°F3 (–18°C to 538°C) ASTM C411
Jacket Temperature Limitation –20°F to 150°F (–29°C to 66°C) ASTM C1136
Jacket Permeance 0.02 perm ASTM E96, Proc. A
Minimum Burst Strength 100 psi ASTM D774/D774M
Fungi Resistance Meets requirements ASTM C1338
Composite Surface Burning Characteristics4Flame Spread: 25
Smoke Developed: 50UL 723, ASTM E84 or CAN/ULC-S102
2. Limited to single-layer applications above 650°F (343°C), but not greater than 6" (152mm) thickness.3. With heat-up schedule.4. The surface burning characteristics of these products have been determined in accordance with UL 723, ASTM E84 or CAN/ULC-S102. These standards should be used
to measure and describe the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating.
7. If the operating temperature of the system is below 100°F (37°C), the pipe insulation terminated exposed end shall be sealed with a vapor barrier mastic applied over the exposed end per the mastic manufacturer’s instructions.
8. Apply systems identification labels by pressure-sensitive labels, or by stencil with spray paint.
No Wrap installation instructions1. Open the hinged sections and place over the pipe,
carefully aligned and secured by wires or bands.
2. Jacket and vapor seal as required by the application.
Additional installation instructions for both
1. Outdoor applications must be protected from weather.
2. If painting is required, use only water based latex paint.
Heat-up schedule• Pipe insulation may be installed while the system is
in operation at temperatures up to 1,000°F (538°C) at a maximum thickness of 6".
• For insulation thicknesses greater than 6" (152 mm), the temperature must be increased from 500°F (260°C) to maximum temperature at a rate not exceeding 100°F (56°C) per hour.
SPECIFICATIONS
6 SSL II ® with ASJ Max and No Wrap Fiberglas™ Pipe Insulation
No Wrap availability
Pipe Size 1/2"
1"
1-1/
2"
2"
2-1/
2"
3"
3-1/
2"
4"
4-1/
2"
5/8 CT X7/8 CT 1/2 X X X1-1/8 CT 3/4 X X X X1-3/8 CT 1 X X X1-5/8 CT 1-1/4 X X X1-1/2 X X X2-1/8 CT X X2 X X X X X2-5/8 CT X2-1/2 X X X3-1/8 CT X3 X X X X X3-5/8 CT X3-1/2 X X X4-1/8 CT 4 X X X X X4-1/2 X X X5-1/8 CT 5 X X X6-1/8 CT 6 X X X X X X X7 X X X8 X X X X X X9 X X X X10 X X X X X X11 X X X12 X X X X X14 X X X15 16 X X X X17 X X18 X X X X X X X19 20 X X X X21 22 X X23 24 X X X X X25 26 X X27 28 X X29 30 X X X X31 32 X33
MTO (Made to Order). Product availability subject to change. View product guide for details. No Wrap Vaccum Pack is also available in select sizes. However, the No Wrap Vacuum packaging process may cause some breakdown of the mechanical properties, such as the hinge, or cause additional dust in the package. It also may impact the outside diameter of the insulation pertaining to ASTM C585. The user assumes all responsibility for meeting project insulation requirements.
SSL II® with ASJ Max availability
Pipe Size 1/2"
1"
1-1/
2"
2"
2-1/
2"
3"
3-1/
2"
4"
4-1/
2"
5"
5/8 CT X X X7/8 CT 1/2 X X X X1-1/8 CT 3/4 X X X X1-3/8 CT 1 X X X X1-5/8 CT 1-1/4 X X X X1-1/2 X X X X2-1/8 CT X X X X2 X X X X X2-5/8 CT X X X X2-1/2 X X X X X3-1/8 CT X X X3 X X X X X3-5/8 CT X X X3-1/2 X X X X X4-1/8 CT X X X X X4 X X X X X4-1/2 X X X X X X5-1/8 CT X X X5 X X X X X X X6-1/8 CT X X X X6 X X X X X X X X X7 X X X X X X X8 X X X X X X X X X9 X X X X X X X X10 X X X X X X X X X11 X X X X X X X12 X X X X X X X X X14 X X X X X X X X X15 X X X X X X X16 X X X X X X X X X17 X X X X X X18 X X X X X X X X19 X X X X X X20 X X X X X X X21 X X X X X22 X X X X X23 X X24 X X X X X X X25 X X X X X26 X X X X X27 X X28 X X X X X X29 X30 X X X X X31 X32 X X X X33 X X
MTO (Made to Order). Product availability subject to change. View product guide for details.SSL II® with ASJ Max is available in select metric sizes for use with Aquatherm® piping systems.
7
STANDARDS & CODES COMPLIANCE• ASTM C547, Mineral Fiber Pipe Insulation, Type I to
850°F (454°C) (no heat-up schedule needed), and Type IV to 1,000°F (538°C) (with heat-up schedule)
• ASTM C585, Inner and Outer Diameters of Thermal Insulation for Nominal Sizes of Pipe and Tubing
• ASTM C1136, Flexible Low Permeance Vapor Retarders for Thermal Insulation, Type I, II, III, IV
• ASTM C1338, Fungi Resistance of Insulation Materials and Facings
• ASTM C795, Thermal Insulation for Use in Contact with Austenitic Stainless Steel1
• MIL-PRF-22344E, Insulation, Pipe, Thermal, Fibrous Glass
• Nuclear Regulatory Commission Guide 1.36, Non-Metallic Thermal Insulation1
• MIL-DTL-24244D (Ships) Insulation Material with Special Corrosion, Chloride, and Fluoride Requirements1
• US Coast Guard 164.109/70/0 Non-Combustible
• NFPA 90A, 90B
• FHC 25/50
• Does not contain the fire retardant decabrominated diphenyl ether (decaBDE)
• New York City MEA No. 344-83, 408-07-M
Thermal conductivity
Mean Temperature
°F k*
Mean Temperature
°C λ*50 0.22 10 0.03275 0.23 25 0.034
100 0.24 50 0.037150 0.27 100 0.043200 0.29 125 0.047250 0.32 150 0.051300 0.35 175 0.056350 0.39 200 0.062400 0.43 225 0.068450 0.48 250 0.075500 0.54 275 0.082
SSL II ® with ASJ Max and No Wrap Fiberglas™ Pipe Insulation
* k = Btu•in/hr•ft2•°F; λ = W/m•°CApparent thermal conductivity values determined in accordance with ASTM practice C1045 with data obtained by ASTM Test Method C335. Values are nominal, subject to normal testing and manufacturing tolerances.
Understanding k-value and R-valuek-value is the rate of heat flow through a homogeneous material. A simplified equation to determine approximate R-value, is your insulation thickness divided by your k-value (at 75°F Mean Temperature). So, the lower the k-value, the greater the insulating value for a given set of conditions. Pipe and mechanical insulation usually communicates in terms of k-value. However, R-values for pipe insulation can be found on the Fiberglas™ Pipe Insulation Dimensional Data and Nesting Chart (Pub. No. 10018078) or you can visit www.owenscorning.com and use the 3E Plus® program to get more information based on your specific project parameters.
CERTIFICATIONS & SUSTAINABILITY• Certified by SCS Global Services to contain
a minimum of 53% recycled glass content, 31% pre-consumer and 22% post-consumer.
• Jacketed pipe insulation is certified to meet indoor air quality standards under the GREENGUARD Certification Program and the GREENGUARD Gold Certification.
• This product’s Environmental Product Declaration (EPD) has been certified by UL Environment.
• Fiberglas™ Pipe Insulation has received the Cradle to Cradle Products Innovation Institute’s Bronze Level Material Health Certificate
1. Preproduction qualification testing complete and on file. Chemical analysis of each production lot required for total conformance. Certification needs to be specified at time of order.
AVERAGE 53% RECYCLED CONTENT31% PRE-CONSUMER
22% POST-CONSUMER
No Wrap availability
Pipe Size 1/2"
1"
1-1/
2"
2"
2-1/
2"
3"
3-1/
2"
4"
4-1/
2"
5/8 CT X7/8 CT 1/2 X X X1-1/8 CT 3/4 X X X X1-3/8 CT 1 X X X1-5/8 CT 1-1/4 X X X1-1/2 X X X2-1/8 CT X X2 X X X X X2-5/8 CT X2-1/2 X X X3-1/8 CT X3 X X X X X3-5/8 CT X3-1/2 X X X4-1/8 CT 4 X X X X X4-1/2 X X X5-1/8 CT 5 X X X6-1/8 CT 6 X X X X X X X7 X X X8 X X X X X X9 X X X X10 X X X X X X11 X X X12 X X X X X14 X X X15 16 X X X X17 X X18 X X X X X X X19 20 X X X X21 22 X X23 24 X X X X X25 26 X X27 28 X X29 30 X X X X31 32 X33
MTO (Made to Order). Product availability subject to change. View product guide for details. No Wrap Vaccum Pack is also available in select sizes. However, the No Wrap Vacuum packaging process may cause some breakdown of the mechanical properties, such as the hinge, or cause additional dust in the package. It also may impact the outside diameter of the insulation pertaining to ASTM C585. The user assumes all responsibility for meeting project insulation requirements.
8
DESCRIPTIONVaporWick® pipe insulation is a heavy-density Fiberglas™ insulation surrounded by a vented, paper-free jacket. The heart of VaporWick® insulation is a wicking material that transports condensed water to the outside of the system so it can evaporate.
APPLICATION/USEDesigned for pipes with operating temperatures from 32°F (0°C) to 220°F (104°C) where condensation or dripping are concerns.
• Chilled water lines
• Hot, humid operating environments
• Below-ambient-temperature applications
• New construction or retrofit jobs
FEATURES & BENEFITS• Wicking material keeps the insulation dry, minimizing
loss in insulating capacity
• Can be installed directly on wet pipes, so you don’t have to shut the system down
• SSL® Max closure system was developed specifically to work with the jacket to provide a tight, reliable seal without glue or staples
• Good short-term bond, outstanding long-term bond as the acrylic adhesive “grows” on the jacket during the 48-hour wet out period
• 20-year limited warranty** See actual warranty for details, limitations and requirements.
VaporWick® pipe insulation is an innovative product for below-ambient-temperature pipes that wicks moisture away from the pipe to keep the insulation dry.
VaporWick® Pipe Insulation
VaporWick ® Pipe Insulation
SSL® Max closure system
Evaporation vents
Wicking material
Fiberglas™ insulation
Paper-free jacket doesn’t support mold or fungi
VaporWick® pipe insulation
9
Additional installation instructions• Care must be taken during installation to ensure
wick material stays in place while sliding, twisting, turning and aligning insulation sections.
• For complete and detailed installation guidelines, refer to the separate VaporWick® Pipe Insulation Installation Instructions. (Pub. No. 102462)
SPECIFICATIONSPhysical property data
Property Value Test Method
Operating Temperature Range 32°F to 220°F (0°C to 104°C) —Jacket Permeance <0.15 perm ASTM E96, desiccant methodJacket Temperature Limitation 225°F (107°C) ASTM C1136Minimum Burst Strength 55 psi ASTM D774/D774MCorrosion Resistance Meets requirements ASTM C665Fungi Resistance Meets requirements ASTM C1338
Composite Surface Burning Characteristics1Flame Spread: <25
Smoke Developed: <50ASTM E84, UL 723 and
CAN/ULC-S1021. The standards used to determine surface burning characteristics measure and describe the properties of materials, products or assemblies in response to heat and flame under
controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment, which takes into account all of the factors that are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating.
Installation instructions1. VaporWick® pipe insulation is designed for
installation on cold piping and dual-temperature piping operating at temperatures from 32°F (0°C) to 220°F (104°C).
2. Wick material must make a continuous connection (path) through all pipe, flanges, fittings, valves and hangers.
3. Open the hinged sections and place the insulation over the pipe, taking care not to get dirt, dust or moisture on the overlap area. Because the wicking action is aided by gravity, horizontal runs must have the series of evaporating holes located in the down position.
4. Pull the release strip from the lap and seal the insulation.
5. Apply the butt strip centered over the adjoining pipe sections and rub with firm pressure to complete the positive closure.
6. All system terminations should be sealed with mastic, including end-of-run transitions to other material.
Note: Auxiliary items include rolls of wick material, VaporWick® Pipe Insulation evaporation skirt (hula skirt) for verticals and butt joint sealing tape for system closure.
0.150.170.190.210.230.250.270.290.31
50 75 100 150 200Mean Temperature, ºF
Con
duct
ivity
Btu
• in/h
r• ft.2 •
ºF
Thermal conductivity
Mean Temperature
°F k*
Mean Temperature
°C λ*50 0.22 10 0.032
75 0.23 25 0.034
100 0.24 50 0.037
150 0.27 100 0.043
200 0.29 125 0.047
* k = Btu•in/hr•ft2•°F; λ = W/m•°CApparent thermal conductivity data determined in accordance with ASTM Practice C1045 with data obtained by ASTM Test Method C335. Values are nominal, subject to normal testing and manufacturing tolerances.
VaporWick ® Pipe Insulation
Fiberglas™ insulation
10
STANDARDS & CODES COMPLIANCE• ASTM C547, Mineral Fiber Pre-Formed Pipe
Insulation, Type I1
• ASTM C585, Inner and Outer Diameters of Thermal Insulation for Nominal Sizes of Pipe and Tubing
• ASTM C795, Thermal Insulation for Use in Contact with Austenitic Stainless Steel2
• Nuclear Regulatory Commission Guide 1.362
• NFPA 90A
• NYC MEA No. 349-02M
• Does not contain the fire retardant decabrominated dophenyl ether (decaBDE)
CERTIFICATIONS & SUSTAINABILITY• Certified by SCS Global Services to contain
a minimum of 53% recycled glass content, 31% pre-consumer and 22% post-consumer.
• Certified to meet indoor air quality standards under the GREENGUARD Indoor Air Quality Certification Program and the GREENGUARD Gold Certification.
• This product’s Environmental Product Declaration (EPD) has been certified by UL Environment.
• Fiberglas™ Pipe Insulation has received the Cradle to Cradle Products Innovation Institute’s Bronze Level Material Health Certificate
1. Exception required for max use temp.
2. Preproduction qualification testing complete and on file. Chemical analysis of each production lot required for total conformance.
VaporWick ® Pipe Insulation
Availability
Pipe Size 1"
1-1/
2"
2"
2-1/
2"
3"
5/8 CT X X7/8 CT 1/2 X X X1-1/8 CT 3/4 X X X1-3/8 CT 1 X X X1-5/8 CT 1-1/4 X X X1-1/2 X X X2-1/8 CT X X X2 X X X X2-5/8 CT X X X2-1/2 X X X X3-1/8 CT X X X3 X X X X3-5/8 CT 3-1/2 X X4-1/8 CT X X X4 X X X X X4-1/2 5-1/8 CT X5 X X X X6-1/8 CT X6 X X X X7 X X X8 X X X X9 X X X10 X X X X X11 X X X X12 X X X14 X X X15 16 X X X17 18 X X19 20 X X21 22 X23 24 X X25 26 27 28 X
MTO (Made to Order). Product availability subject to change. View product guide for details.
11
Thickness to prevent surface condensation
Fluid temperature 35°F Pipe size, NPS, in.
Ambient temperature °F Relative humidity % ½ 1 1-½ 2 4 6 8 10 12 80 70 1 1 1 1 1 1 1 1 1
80 1 1 1 1 1 1 1 1-½ 1-½
90 1-½ 1-½ 2 2 2 2 2-½ 2-½ 2-½
90 70 1 1 1 1 1 1 1 1 1
80 1 1 1 1 1 1-½ 1-½ 1-½ 1-½
90 2 2 2 2-½ 3 3 3 3 3-½
Fluid temperature 45°F Pipe size, NPS, in.
Ambient temperature °F Relative humidity % ½ 1 1-½ 2 4 6 8 10 12 80 70 1 1 1 1 1 1 1 1 1
80 1 1 1 1 1 1 1 1 1
90 1 1-½ 1-½ 1-½ 1-½ 2 2 2 2
90 70 1 1 1 1 1 1 1 1 1
80 1 1 1 1 1 1 1 1 1
90 1-½ 2 2 2 2-½ 2-½ 2-½ 2-½ 3
Fluid temperature 55°F Pipe size, NPS, in.
Ambient temperature °F Relative humidity % ½ 1 1-½ 2 4 6 8 10 12 80 70 1 1 1 1 1 1 1 1 1
80 1 1 1 1 1 1 1 1 1
90 1 1 1 1 1-½ 1-½ 1-½ 1-½ 1-½
90 70 1 1 1 1 1 1 1 1 1
80 1 1 1 1 1 1 1 1 1
90 1-½ 1-½ 1-½ 1-½ 2 2 2 2 2
VaporWick® pipe insulation does not prevent surface condensation. Sufficient thickness must be selected to minimize condensation on the outer surface.All thicknesses are in inches rounded up to the nearest half inch.
Recommendations were developed using the NAIMA 3E Plus® computer program, assuming wind speed of 0 mph and outer jacket emittance of 0.9.
AVERAGE 53% RECYCLED CONTENT31% PRE-CONSUMER
22% POST-CONSUMER
VaporWick ® Pipe Insulation
12
FOAMULAR® XPS Pipe Insulation can be cut to fit many types of pipe installations.
FOAMULAR® XPS Pipe InsulationExtruded Polystyrene (XPS) fabrication billets have a unique closed-cell structure that resists water absorption and maintains R-value in low-temperature systems and conditions of high humidity and moisture.
DESCRIPTIONFOAMULAR® XPS Pipe Insulation is a raw block of insulation which can be cut to fit a variety of applications. They are manufactured using Owens Corning’s patented Hydrovac® process, and factory-laminated using a specially formulated polyurethane-based adhesive.
APPLICATION/USECommercial pipe fabricators can cut FOAMULAR® XPS Pipe Insulation to fit a variety of applications and individual pipe insulation parts.
• Ammonia/refrigeration lines
• Chilled water piping
• Refrigeration and cold storage systems
• Freezer rooms
• Pharmaceutical plants
• Transport pipelines
• Direct burial applications
• Saddle supports in fiberglass pipe insulation systems
FEATURES & BENEFITS• Highly resistant to moisture
• Low water absorption
• High insulating capabilities
• Long service life with consistent R-values
• Durable compressive strength of 25 PSI
• Manufactured in the USA
• Limited lifetime warranty** Warranted that the insulation will maintain 90% of its R-value for the lifetime of
the building and covers all ASTM C578 properties. See actual warranty for details, limitations and requirements.
FOAMULAR ® XPS Pipe Insulation
Pipe
Thin coat of Vapor Retarder Joint Sealant
PVC jacket
Pipe support saddle
Vapor Retarder
Vapor Retarder Joint Sealant “Buttered”
Pipe support hanger
13
Samples modified as required to meet applicable test methods. 1. XPS foam core value2. k = Btu•in./hr•ft2•°F; λ = W/m•°C. The lower the value, the greater the insulation power.3. Values at yield or 10% deflection, whichever occurs first.4. Water vapor permeance decreases as thickness increases.5. Burning characteristics laboratory tests are not intended to describe the hazard presented by this material under actual fire conditions. 6. Test results are for FOAMULAR 4" thick product only. Thicker products may have different fire performance characteristics. Due to limits on the equipment used to test per ASTM
E84, Owens Corning FOAMULAR XPS Pipe Insulation have not been tested.7. Fire performance of products fabricated using FOAMULAR XPS Pipe Insulation may vary in the field depending on facings and adhesives used in the fabrication process.
Fabricators should be consulted if composite fire performance is required.
Physical property data
Property Value Test Method
Density 1.55 lb./ft3 (25 kg/m3) ASTM D1622
Maximum Thermal Conductivity1,2
180 days at 75°F mean temperature k = 0.200 (λ = 0.029) ASTM C518
Maximum Compressive Strength1,3 25 psi (173 kPa) ASTM D1621
Maximum Water Absorption1 0.00–0.15% by volume ASTM E96
Maximum Water Vapor Permeance1,4 1.5 perm (86 ng/Pa × s × m2) ASTM E96
Dimensional Stability1 1.0% linear change ASTM D2126
Composite Surface Burning Characteristics1,5,6,7
Flame Spread: 5Smoke Developed: 175
ASTM E84
Maximum Service Temperature –100°F to 165°F (–73°C to 74°C)
Linear Coefficient of Thermal Expansionin/in × °F: 3.5 × 10–5
(mm/mm × °C: 6.3 × 10–5)ASTM E228
SPECIFICATIONSAvailabilityFOAMULAR® XPS Pipe Insulation is available in several sizes:
• Thicknesses: - 8", 16", 20", 24"
• Width: - 24", 48"
• Length: - 37" - 120"
• Standard stock: - 24" x 48" x 74"
FOAMULAR ® XPS Pipe Insulation
Thermal conductivity
Mean Temperature
°F k*
Mean Temperature
°C λ*100 .214 37.7 .031
75 .200 23.9 .029
50 .188 10.0 .027
25 .179 -5.9 .026
0 .173 -17.8 .025
-25 .169 -31.7 .025
-50 .166 -45.6 .024
-75 .164 -59.4 .024
-100 .160 -73.3 .023
* k = Btu•in/hr•ft2•°F; λ = W/m•°CApparent thermal conductivity data determined in accordance with ASTM Practice C1045 with data obtained by ASTM Test Method C335. Values are nominal, subject to normal testing and manufacturing tolerances.
14
Installation instructions1. Insulation materials and accessories should be
installed only by experienced chilled water or refrigeration insulation professionals. Ultimate design and installation are the responsibility of the engineer or architect.
2. Insulation should be free from all moisture prior to installation.
3. Ensure joints are staggered in multi-layer applications.
4. Refer to ASTM C755 for information on selection and specification of vapor retarders and sealing tape.
5. Protective jacketing should be installed in accordance to the application and location needs.
6. See FOAMULAR® XPS Pipe Insulation Installation Guidelines (Pub. No. 10013974) for more detailed installation instructions.
Additional installation instructions
• FOAMULAR® XPS Pipe Insulation is subject to deterioration from prolonged exposure to ultraviolet light. Exposure to ultraviolet light should be limited to 30 days over the life of the material.
CERTIFICATIONS & SUSTAINABILITY• Certified by SCS Global Services to contain a
minimum 20% recycled polystyrene content.
• Certified to meet indoor air quality standards under the GREENGUARD Indoor Air Quality Certification Program and the GREENGUARD Gold Certification.
• This product’s Environmental Product Declaration (EPD) has been certified by UL Environment.
FOAMULAR ® XPS Pipe Insulation
15
Availability
Thickness Facing Recommended Pipe Size Roll Lengthin. (mm) NPS in. (DN, mm) ft. (m)1 (25) ASJ Max 10 (250) + 42 (12.8)
1-½ (38) ASJ Max 10 (250) + 27 (8.2)2 (51) ASJ Max 10 (250) + 20 (6.1)2 (51) FRK 10 (250) + 20 (6.1)
2-½ (64) ASJ Max 14 (350) + 26 (7.9)2-½ (64) FRK 14 (350) + 26 (7.9)
3 (76) ASJ Max 17 (425) + 21 (6.4)3-½ (89) ASJ Max 20 (500) + 18 (5.5)
4 (102) ASJ Max 23 (575) + 16 (4.9)
DESCRIPTIONOwens Corning’s versatile Fiberglas™ pipe and tank insulation is a semi-rigid insulation with a factory-jacketed FRK or ASJ Max encapsulated-paper jacket. It’s flexible enough to be used in many different applications while providing the rigidity and thermal performance you need for a well-insulated system.
APPLICATION/USEFiberglas™ Pipe and Tank insulation provides thermal protection for a variety of objects and shapes. Fits pipes and equipment of 10" NPS and larger.
• Pipes
• Tanks
• Pipe flanges
Fiberglas™ Pipe and Tank Insulation provides a flexible insulation product for wrapping pipes, tanks, or irregularly shaped objects while providing excellent rigidity and abuse resistance.
Fiberglas™ Pipe & Tank Insulation
FEATURES & BENEFITS• May be applied over existing insulation to increase
thickness and conserve energy
• Vertical fiber orientation with a durable, high-compressive strength makes it strong and abuse resistant
ASJ Max Jacket
• Durable, cleanable poly-encapsulate paper jacket that doesn’t support mold or mildew growth
• Resists/sheds water when exposed to intermittent, short-duration precipitation during construction
• Less wicking and curling than standard ASJ
• Accepts paint and mastic as well as standard ASJ
• Higher puncture resistance than standard ASJ
• Has a finished appearance that is compatible with standard ASJ
• Valves
• Groups of parallel pipes
• Pipes with heat tracing lines
SPECIFICATIONS
Fiberglas ™ Pipe and Tank Insulation
MTO (Made to Order). Product availability subject to change. View product guide for details. All rolls are 36" wide.
16
Thermal conductivity
Mean Temperature
°F k*
Mean Temperature
°C λ*50 0.26 10 0.03775 0.27 25 0.040
100 0.29 50 0.045150 0.33 75 0.050200 0.38 100 0.056250 0.43 125 0.063300 0.49 150 0.070350 0.55 175 0.078
Con
duct
ivity
Btu
• in/h
r• ft.2 •
ºF
50 100 150 20075 250 300 350Mean Temperature, ºF
0.2
0.3
0.4
0.5
0.6
* k = Btu•in/hr•ft2•°F; λ = W/m•°CApparent thermal conductivity data determined in accordance with ASTM Practice C1045 with data obtained by ASTM Test Method C335. Values are nominal, subject to normal testing and manufacturing tolerances.
Installation instructions1. Measure the length of insulation required according
to the fabrication guide located on the carton.
2. Cut completely through the insulation and jacket. Use a flap tool to fillet a stapling flange on one end of the insulation.
3. Each section of insulation may be secured around the pipe using either outward-clenching staples and mastic or outward-clenching staples and pressure-sensitive, vapor-retarder tape.
4. Adjacent sections must be tightly butted together and then sealed with vapor-retarder tape.
Additional installation instructions• Special care must be taken to vapor-seal systems
operating below ambient temperatures.
• If indoor applications will be painted, use only a water-based latex paint.
• Outdoor applications require protection from weather.
1. The standard used to determine surface burning characteristics measures and describes the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment, which takes into account all of the factors that are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating.
Physical property data
Property Value Test Method
Pipe/equipment Operating Temperature(single-layer application)
0°F to 650°F (–18°C to 343°C) ASTM C411
Insulation Jacket Temperature Limitation –20°F to 150°F (–29°C to 66°C) ASTM C1136
Jacket Permeance 0.02 perm ASTM E96, Proc. A
Minimum Burst Strength 100 psi ASTM D774/D774M
Compressive Strength at 10% Deformation 125 lb./ft2 (5985 Pa) min. ASTM C165
Surface Burning Characteristics1Flame Spread: 25
Smoke Developed: 50ASTM E84
Fiberglas ™ Pipe and Tank Insulation
17
STANDARDS & CODES COMPLIANCE• ASTM C1393, Standard Specification for
Perpendicularly Oriented Mineral Fiber Roll and Sheet Thermal Insulation for Pipes and Tanks, Types I, II, IIIA, IIIB and Category 2
• ASTM C795, Thermal Insulation for Use in Contact with Austenitic Stainless Steel2
• ASTM C1136, Flexible Low Permeance Vapor Retarders for Thermal Insulation, Types I, II, III, IV
• Mil. Spec. MIL-1-24244C, Insulation Materials, Special Requirements, Type XVlh2
• Nuclear Regulatory Commission Guide 1.36, Non-Metallic Thermal Insulation2
• Does not contain the fire retardant decabrominated diphenyl ether (decaBDE)
Thermal performance
InsulationNPS x Thk. In. (DN x Thk. mm) Heat Loss Btu/hr x ft (W/m) Surface Temperature °F (°C)
300°F (149°C) Pipe Operating Temperature12 × 1 (300 × 25) 251 (241) 121 (49)18 × 1 (450 × 25) 345 (332) 122 (50)24 × 1 (600 × 25) 453 (436) 123 (51)30 × 1 (750 × 25) 561 (539) 123 (51)
450°F (232°C) Pipe Operating Temperature12 × 2 (300 × 51) 292 (281) 122 (50)18 × 2 (400 × 51) 414 (398) 126 (52)24 × 2 (600 × 51) 539 (518) 127 (53)30 × 2 (750 × 51) 663 (637) 127 (53)
600°F (316°C) Pipe Operating Temperature12 × 3 (300 × 76) 370 (356) 127 (53)
18 × 3-½ (450 × 89) 449 (432) 124 (51)24 × 3-½ (600 × 89) 576 (554) 125 (52)30 × 3-½ (750 × 89) 702 (675) 126 (52)
Data determined in accordance with ASTM C680. Design conditions: horizontal piping, 80°F (27°C) average ambient temperature, 0 mph wind speed, ASJ Max jacket.
2. Preproduction qualification testing complete and on file. Chemical analysis of each production lot required for total conformance.
CERTIFICATIONS & SUSTAINABILITY• Certified by SCS Global Services to contain
a minimum of 53% recycled glass content, 31% pre-consumer and 22% post-consumer.
AVERAGE 53% RECYCLED CONTENT31% PRE-CONSUMER
22% POST-CONSUMER
Fiberglas ™ Pipe and Tank Insulation
18
DESCRIPTIONFlexwrap® Fiberglas™ insulation is a flexible pipe and tank wrap made from Fiberglas™ blanket bonded together with a thermosetting resin and backed with an ASJ, FRK, or PSK facing. It is a cost-effective alternative to larger-sized, preformed pipe insulation.
APPLICATION/USE It provides a continuous blanket for round or irregularly shaped surfaces in indoor settings.
• Pipes
• Tanks
• Pipe flanges
• Valves
• Groups of parallel pipes
FEATURES & BENEFITS
Flexwrap® Fiberglas™ Insulation provides flexibility for insulating pipes, tanks or irregularly shaped objects and features a low thermal conductivity.
Flexwrap® Fiberglas™ Insulation
• Low thermal conductivity compared with segmented products, which means less thickness is required
• It fits pipes and equipment of 10" NPS or larger, reducing the need to stock insulation to fit pipes in multiple diameters
• Delivers good compressive strength while providing flexibility during installation
• May be applied over existing insulation to increase thickness and conserve energy
Flexwrap® Fiberglas™ Insulation is an economic and versatile choice for insulating pipes, tanks and irregularly shaped surfaces.
Flexwrap ® Fiberglas™ Insulation
19
Physical property data
Property Value Test Method
Maximum Use Temperature 850°F (454°C) ASTM C411
Density 2.5 pcf (40 kg/m3) ASTM C303
Compressive Resistance 25 psf (1200 Pa) ASTM C165
Corrosiveness Meets requirements ASTM C665
Fungi Resistance Meets requirements ASTM C1338
Facing Temperature Limit 150°F (66°C) ASTM C1136
Water Vapor Permeance (Facing) 0.02 perm ASTM E96
Surface Burning Characteristics1Flame Spread: 25
Smoke Developed: 50ASTM E84
1. The standard used to determine surface burning characteristics measures and describes the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment, which takes into account all of the factors that are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating.
MTO (Made to Order). Product availability subject to change. View product guide for details.All rolls are 48" (1,219 mm) wide.
Installation instructions1. When determining length requirements, remember
to add twice the thickness of Flexwrap® insulation to the diameter when calculating the circumference of the piece being insulated.
2. If a lap is desired, add 3" to 4" of length and remove the additional insulation, taking care not to cut the facing, to form the lap.
3. Flexwrap® insulation is installed around the surface to be insulated, secured and either taped or stapled with outward-clenching staples. If necessary, apply a vapor-retarder mastic.
Additional installation instructions• Adjacent sections should be butted together and
sealed with tape.
• Use of bands or impalement pins for securement purposes is permitted but should be sealed as necessary with mastic.
• When the application requires a vapor seal, all joints and facing penetrations must be sealed with appropriate pressure-sensitive tape or vapor-retarder mastic.
SPECIFICATIONS
Flexwrap ® Fiberglas™ Insulation
Availability
Thickness Facing Length
Minimum Wrap
Diameter (NPS)
in. (mm) ft. (m) in. (mm)
1.5 (38) FRK 30 (9.14) 8 (203)
1.5 (38) ASJ 30 (9.14) 8 (203)
1.5 (38) PSK 30 (9.14) 8 (203)
2 (51) FRK 26 (7.92) 10 (254)
2 (51) ASJ 26 (7.92) 10 (254)
2.5 (64) FRK 20 (6.1) 12 (305)
2.5 (64) ASJ 20 (6.1) 12 (305)
2.5 (64) PSK 20 (6.1) 12 (305)
3 (76) FRK 18 (5.48) 16 (406)
3 (76) ASJ 18 (5.48) 16 (406)
20
Thermal conductivity
Mean Temperature
°F k*
Mean Temperature
°C λ*75 0.24 25 0.035
100 0.25 50 0.038200 0.32 100 0.047300 0.40 150 0.058400 0.48 200 0.069500 0.58 250 0.081
0 200100 300 400 500Mean Temperature, ºF
0.0
0.1
0.2
0.3
0.4
0.5
0.6
Con
duct
ivity
Btu
• in/h
r• ft.2 •
ºF
Stretch-out requirements
Flexwrap ThicknessPipe OD 1.5 in. (38mm) 2 in. (51mm) 2.5 in. (64mm) 3 in. (76mm)
NPS in. in. (mm) in. (mm) in. (mm) in. (mm)
6 6.6
8 8.6 36.5 (928)
10 10.8 43.5 (1,104) 46.6 (1,184)
12 12.8 49.7 (1,263) 52.9 (1,343) 56.0 (1,423)
14 14 53.5 (1,359) 56.6 (1,439) 59.8 (1,519)
16 16 59.8 (1,519) 62.9 (1,598) 66.1 (1,678) 69.2 (1,758)
18 18 66.1 (1,678) 69.2 (1,758) 72.4 (1,838) 75.5 (1,917)
20 20 72.3 (1,838) 75.5 (1,917) 78.6 (1,997) 81.8 (2,077)
22 22 78.6 (1,997) 81.8 (2,077) 84.9 (2,157) 88.0 (2,236)
24 24 84.9 (2,157) 88.1 (2,236) 91.2 (2,316) 94.3 (2,396)
26 26 91.2 (2,316) 94.3 (2,396) 97.5 (2,476) 100.6 (2,555)
28 28 97.5 (2,476) 100.6 (2,555) 103.7 (2,635) 106.9 (2,715)
30 30 103.7 (2,635) 106.9 (2,715) 110.0 (2,795) 113.2 (2,874)
32 32 110.0 (2,795) 113.2 (2,874) 116.3 (2,954) 119.5 (3,034)
34 34 116.3 (2,954) 119.4 (3,034) 122.6 (3,114) 125.7 (3,193)
36 36 122.6 (3,114) 125.7 (3,193) 128.9 (3,273) 132.0 (3,353)Lengths provided do not include a staple flap. Add 3–4 inches of length if a staple flap is desired.
STANDARDS AND CODES COMPLIANCE• ASTM C1393, Standard Specification for
Perpendicularly Oriented Mineral Fiber Roll and Sheet Thermal Insulation for Pipes and Tanks, Types I, II, IIIA, IIIB, and Category 2
* k = Btu•in/hr•ft2•°F; λ = W/m•°C
• Does not contain the fire retardant decabrominated diphenyl ether (decaBDE)
Flexwrap ® Fiberglas™ Insulation
21
DESCRIPTIONUtiliCore® Fiberglas™ insulation is a lightweight, flexible blanket for use as core insulation in removable and reusable pipe covers and other industrial pads and blankets. The L Series products are low-binder blankets, while the HP5 II Mat is a needled blanket with no binder.
APPLICATION/USEUtiliCore® Fiberglas™ insulation has a maximum operating temperature of 1,000°F. The dimensional stability and thermal performance make fabrication, assembly and installation easy.
• Industrial piping system insulation covers
• Valve insulation covers
• Flange insulation covers
• Exchanger covers
• Boiler covers
• Tank covers
UtiliCore® Fiberglas™ insulation products are flexible white blankets designed as core insulation for commercial and industrial applications.
UtiliCore® Fiberglas™ Insulation
FEATURES & BENEFITS• Lighter weight than traditional E glass products
at equivalent R-values• Flexible, lightweight structure easily fits into the
corners of pads and allows you to sew directly through the material
• Soft fibers have less dust and cause less itch and irritation
• Available in a variety of densities from 1 – 5 PCF to suit your application and needs
• Good tensile strength, resilience and thickness control
• Contains no RCF (Refractory Ceramic Fibers)
SPECIFICATIONS Installation instructions
Installation will vary by application depending on insulation requirements, jacket requirements and mechanical closure needs.
UtiliCore ® Fiberglas™ Insulation
22
Physical property data
Property Value Test Method
Operating Temperature Range up to 1,000°F (538°C) ASTM C411
Corrosion Resistance Meets requirements ASTM C665
Fungi Resistance Meets requirements ASTM C1338
Odor No objectionable odor ASTM C1304
Moisture Sorption <3% by weight ASTM C1104
Composite Surface Burning Characteristics1Flame Spread: <25
Smoke Developed: <50ASTM E84, UL 723
and CAN/ULC-S102
UtiliCore ® Fiberglas™ Insulation
1. The standards used to determine surface burning characteristics measure and describe the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of these tests may be used as elements of a fire risk assessment, which takes into account all of the factors that are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating.
Thermal conductivity (Core insulation only)
UtiliCore Insulation
L1 L1.3 L1.8 L2.5 L3.7 HP5 II Mat
Thickness2 (in.) 1.0 1.0 1.0 1.0 1.0 1.0
Density (pcf) 1.0 1.3 1.8 2.5 3.7 5.0
Nominal k3
75°F 0.26 0.24 0.23 0.22 0.21 0.21
300°F 0.51 0.46 0.39 0.35 0.31 0.30
500°F 0.85 0.75 0.62 0.52 0.44 0.42
Nominal λ4
23°C 0.037 0.035 0.033 0.032 0.031 0.031
149°C 0.074 0.066 0.056 0.050 0.045 0.044
260°C 0.123 0.108 0.089 0.075 0.063 0.060
2. Thickness value is nominal. Product control is on thermal conductivity. 3. k = Btu•in./hr•ft.2•°F (R-value = thickness/K) 4. λ = W/mK
Availability
Product Single Roll/ Double Roll Thickness Width Length
L1 Single Roll 1” 60” 87’L1 Double Roll 1” 60” 87’L1.3 Single Roll 1” 60” 87’L1.3 Double Roll 1” 60” 87’L1.8 Single Roll 1” 60” 54’L1.8 Double Roll 1” 60” 54’L2.5 Single Roll 1” 60” 43’L2.5 Double Roll 1” 60” 43’L2.5 Single Roll 1.5” 60” 58’
MTO (Made to Order). Product availability subject to change. View product guide for details.
Product Single Roll/ Double Roll Thickness Width Length
L2.5 Single Roll 2” 24” 28’L2.5 Single Roll 2” 60” 43’L3.7 Single Roll 1” 60” 28’L3.7 Double Roll 1” 60” 28’L3.7 Single Roll 2” 24” 28’L3.7 Single Roll 2” 60” 28’HP5 Mat Single Roll .5” 30” 100’HP5 Mat Single Roll 1” 60” 45’HP5 Mat Single Roll 1” 60” 50’
23UtiliCore ® Fiberglas™ Insulation
Density Variance for MIL-I-22023DUtiliCore® insulation complies with MIL-I-22023D, with the exception of Section 1.2 Classification; Table I Nominal Density; Type I and Type II, for Class 4 and Class 6, which are slightly below the -10% allowance, but complies to all properties required for these classes. The table below aligns the UtiliCore® insulation product for Type I and Type II Classes.
Density Required pcf (lb/ft3) UtiliCore Product Product Product Density (lb/ft3)Class 3 1.0 L1 1.0
Class 4 1.5 L1.3 1.3
Class 5 2.0 L1.8 1.8
Class 6 3.0 L2.5 2.5
Sound absorption coefficient
Octave Band Center Frequencies, Hz
ProductThickness
(in.) 125 250 500 1000 2000 4000 NRC SAAL1 1.0 0.09 0.31 0.65 0.85 0.90 0.90 0.70 0.68
L1.3 1.0 0.17 0.45 0.84 0.94 0.96 0.93 0.80 0.80
L1.8 1.0 0.13 0.39 0.77 0.94 1.01 0.99 0.80 0.78
L2.5 1.0 0.08 0.34 0.81 0.98 1.03 1.03 0.80 0.79
L3.7 1.0 0.10 0.57 1.09 1.17 1.12 1.17 1.00 0.99
HP5 Mat 1.0 0.13 0.43 0.84 1.05 1.02 0.94 0.85 0.83
Nominal samples were measured in accordance with ASTM C423 with Type A mounting. These measured absorption coefficients were adjusted to values representative of the product with mean specification properties. While these values are an accurate representation of our product, they are for design approximation only. Production, testing and application variabilities will alter results. Specific designs should be evaluated in end-use configurations.
STANDARDS & CODES COMPLIANCE• ASTM C553, Mineral Fiber Blanket Thermal
Insulation, Type V - All UtiliCore
• ASTM C1086, Glass Fiber Mechanically Bonded Felt Thermal Insulation (HP5 Mat)
• ASTM C1139 Fibrous Glass Thermal Insulation and Sound Absorbing Blanket and Board for Military Applications
• MIL-I-16411E, Insulation Felt, Thermal, Glass Fiber
• MIL-I-22023D, Insulation Felt, Thermal and Sound Absorbing Felt, Fibrous Glass, Flexible
• ASTM C795, Thermal Insulation for Use in Contact with Austenitic Stainless Steel5
• Nuclear Regulatory Commission Guide 1.36, Non-Metallic Thermal Insulation5
• MIL-I-24244D (Ships) Insulation Material with Special Corrosion, Chloride, and Fluoride Requirements5
• U.S. Coast Guard Approval No. 164.109, Noncombustible Materials
CERTIFICATIONS & SUSTAINABILITY6
• Certified by SCS Global Services to contain a minimum of 53% recycled glass content, 31% pre-consumer and 22% post-consumer.
• Certified to meet indoor air quality standards under the GREENGUARD Indoor Air Quality Certification Program and the GREENGUARD Gold Certification.
5. Preproduction qualification testing complete and on file. Chemical analysis of each production lot required for total conformance.
6. Results representative of core insulation only.
• ASTM E136, Behavior of Materials in a Vertical Tube Furnace at 750°C (Noncombustible rating)
• Does not contain the fire retardant decabrominated diphenyl ether (decaBDE)
UtiliCore offers no Class 2 product.
AVERAGE 53% RECYCLED CONTENT31% PRE-CONSUMER
22% POST-CONSUMER
24
DESCRIPTION700 Series Fiberglas™ Insulation is made of inorganic glass fibers with a thermosetting resin binder and formed into flexible, semi-rigid or rigid rectangular boards in a variety of densities, thicknesses and facing options.
APPLICATION/USEThe range of options available for 700 Series Fiberglas™ Insulation, make it incredibly versatile and a great choice for a wide range of acoustic and thermal insulating needs.
Type 701• A lightweight, flexible option used as acoustic
insulation batts• Insulate items with irregularly-shaped surfaces
where compressive strength is not a performance criterion and the exterior finish will be supported mechanically
Type 703• Semi-rigid boards for use on mechanical equipment
and HVAC ductworkType 705• High strength, rigid board for use on chillers,
other mechanical equipment and HVAC ductwork where high abuse resistance and good finished appearance are important
Types 706 & 707• Smooth surface, high density, rigid boards used
for acoustical wall panels and specialized ceiling applications
700 Series Fiberglas™ Insulation
FEATURES & BENEFITS• Lightweight and resilient
• Easy to handle, fabricate and install
• Wide variety of options allows you to match your job requirements
• Types 703 and 705 are available with a factory-applied FRK or ASJ Max vapor retarder facing
ASJ Max Facing
• Durable, cleanable, poly-encapsulated paper facing that doesn’t support mold or mildew growth
• Resists/sheds water when exposed to intermittent, short-duration precipitation during construction
• Accepts paint and mastic as well as standard ASJ.
• Higher puncture resistance than standard ASJ
• Has a finished appearance that is compatible with standard ASJ
This versatile line of Fiberglas™ insulation is great for acoustic and thermal insulation. It helps reduce sound transmission, heat transfer and helps save energy which can lead to lower operating costs.*
700 Series Fiberglas ™ Insulation
*Savings vary.
25
Physical property data
Property Value Test Method
Equipment Operating Temperature Limitation1 0 to 450˚F (-18˚C to 232˚C) ASTM C411
Insulation Jacket Temperature Limitation -20˚F to 150˚F (-29˚C to 66˚C) ASTM C1136
Jacket Permeance 0.02 perm ASTM E96, Proc. A
Jacket Burst Strength FRK: 35 psi; ASJ Max: 100 psi ASTM D774
Compressive Strength (minimum) at 10% deformation at 25% deformation
Type 70325 lb/ft2 (1197 Pa)90 lb/ft2 (4309 Pa)
Type 705200 lb/ft2 (9576 Pa)
—ASTM C165
Water Vapor Sorption <2% by weight at 120°F (49°C), 95% R.H. ASTM C1104
Nominal Density Type 701: 1.5 pcf (24 kg/m3) ASTM C167
Type 703: 3.0 pcf (48 kg/m3) ASTM C303
Type 705, 706: 6.0 pcf (96 kg/m3)
Type 707: 7.0 pcf (112 kg/m3)
Surface Burning Characteristics2Flame Spread: 25
Smoke Developed: 50UL 723, ASTM E84 or CAN/ULC-S102
1. Maximum thickness at 450˚F (232˚C): Type 701: 6" (152mm); Type 703, 705, 706: 4" (102mm).2. The surface burning characteristics of these products have been determined in accordance with UL 723, ASTM E84 or CAN/ULC-S102. This standard should be used to measure
and describe the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating.
SPECIFICATIONS
Thermal performanceASTM C680 (Type 703)
Operating Temperature, ˚F (˚C)Thickness 250 (121) 300 (149) 350 (177) 400 (204) 450 (232)
in. (mm) HL ST HL ST HL ST HL ST HL ST1.0 (25) 27 98 42 106 57 114 75 123 95 1331.5 (38) 19 93 29 99 40 105 52 112 66 1192.0 (5l) 15 90 22 95 31 100 40 105 50 1112.5 (64) 12 88 18 92 25 96 32 101 41 1063.0 (76) 10 87 15 91 21 94 27 98 34 1023.5 (89) 9 86 13 89 18 92 23 96 30 994.0 (102) 8 86 11 88 16 91 21 94 26 97
The above table provides approximate heat loss values (HL), Btu/hr•ft2, and Surface Temperatures (ST), °F, for flat surfaces. Values are based on horizontal heat flow, vertical flat surface, 80°F ambient temperature, still air, ASJ Max facing. To convert heat loss values to W/m2, multiply values by 3.15. To convert surface temperatures, use the formula: °C = (°F-32)/1.8. For similar information using other assumptions, contact your Owens Corning Representative.
700 Series Fiberglas ™ Insulation
26
AvailabilityType Facing Thickness Size Pieces/Pack701 UF (Unfaced) 1” 24”x48” 32701 UF 1.5” 24”x48” 24701 UF 2” 24”x48” 16701 UF 2.5” 24”x48” 13701 UF 3” 24”x48” 12701 UF 4” 24”x48” 9703 UF 1” 24”x48” 24703 UF 1” 24”x48” 72703 UF 1” 48”x96” 12703 UF 1” 48”x96” 40703 UF 1” 48”x96” 42703 UF 1” 48”x96” 48703 UF 1” 48”x120” 44703 UF 1” 49”x72” 44703 UF 1.5” 24”x48” 16703 UF 1.5” 24”x48” 48703 UF 1.5” 48”x60” 12703 UF 1.5” 48”x96” 8703 UF 2” 24”x48” 12703 UF 2” 24”x48” 36703 UF 2” 24”x48” 96703 UF 2” 48”x96” 6703 UF 2” 48”x96” 24703 UF 2.5” 24x48” 8703 UF 3” 24x48” 8703 UF 3” 24x48” 60703 UF 3” 36x49” 28703 UF 3” 39x48” 7703 UF 3” 48x96” 4703 UF 4” 24x48” 6703 UF 4” 24x48” 48703 UF 4” 48x96” 12703 UF 4” 37x48” 5703 FRK (Foil Faced) 1” 24x48” 12703 FRK 1” 24x48” 72703 FRK 1” 48x96” 4703 FRK 1.5” 24x48” 8703 FRK 1.5” 24x48” 48703 FRK 1.5” 48x96” 4703 FRK 2” 24x48” 6703 FRK 2” 24x48” 6703 FRK 2” 24x48” 36703 FRK 2” 48x96” 2703 FRK 2.5” 24x48” 5703 FRK 3” 24x48” 4703 FRK 3.5” 24x48” 3703 FRK 4” 24x48” 3703 ASJ Max 1” 24x48” 12703 ASJ Max 1.5” 24x48” 8703 ASJ Max 2” 24x48” 6
Type Facing Thickness Size Pieces/Pack703 ASJ Max 2” 48x96” 2703 ASJ Max 3” 24x48” 4703 ASJ Max 4” 48x96” 2705 UF 0.5” 48x96” 80705 UF 0.75” 24x48” 16705 UF 1” 24x48” 10705 UF 1” 48x96” 42705 UF 1.5” 24x48” 7705 UF 2” 24x48” 5705 UF 2” 36x48” 6705 UF 2” 48x96” 24705 UF 2.5” 48x96” 18705 UF 3” 24x48” 4705 UF 3” 48x96” 15705 FRK 1” 24x48” 12705 FRK 1” 24x48” 12705 FRK 1.5” 24x48” 8705 FRK 1.5” 24x48” 8705 FRK 2” 24x48” 6705 FRK 2” 48x96” 3705 FRK 2.5” 48x96” 18705 FRK 3” 48x96” 15705 ASJ Max 1” 24x48” 12705 ASJ Max 1.5” 24x48” 8705 ASJ Max 2” 24x48” 6705 ASJ Max 3” 48x96” 15
706
SS (Smooth Surface)
UF (Unfaced)
1” 48x96.625” 44
706 SS UF 1” 49x73” 42706 SS UF 1” 49x97” 42706 SS UF 1” 49x121” 42706 SS UF 1.5” 48x96.625” 30706 SS UF 1.5” 48x120” 30706 SS UF 1.5” 49x97” 30706 SS UF 1.5” 49x121” 30706 SS UF 2” 48x96.625” 22706 SS UF 2” 49x73” 22706 SS UF 2” 49x97” 22706 SS UF 2” 49x121” 22706 SS UF 2.5” 48x96.625” 18707 SS UF 1” 49x73” 42707 SS UF 1” 49x97” 42707 SS UF 1” 49x121” 42707 SS UF 1.5” 49x97” 30707 SS UF 1.5” 49x121” 30707 SS UF 2” 49x73” 22707 SS UF 2” 49x97” 22707 SS UF 2” 49x121” 22
MTO (Made to Order). Product availability subject to change. View product guide for details.
700 Series Fiberglas ™ Insulation
27
Sound absorption coefficientsASTM C423; Mounting: Type A–Material placed against a solid backing.
Thickness Octave Band Center Frequencies, HzProduct Type in. (mm) 125 250 500 1000 2000 4000 NRC701, unfaced 1 (25) 0.17 0.33 0.64 0.83 0.90 0.92 0.70
2 (51) 0.22 0.67 0.98 1.02 0.98 1.00 0.90703, unfaced 1 (25) 0.11 0.28 0.68 0.90 0.93 0.96 0.70
2 (51) 0.17 0.86 1.14 1.07 1.02 0.98 1.00705, unfaced and 706 smooth surface
1 (25) 0.02 0.27 0.63 0.85 0.93 0.95 0.65
2 (51) 0.16 0.71 1.02 1.01 0.99 0.99 0.95
703, FRK 1 (25) 0.18 0.75 0.58 0.72 0.62 0.35 0.652 (51) 0.63 0.56 0.95 0.79 0.60 0.35 0.75
705, FRK 1 (25) 0.27 0.66 0.33 0.66 0.51 0.41 0.552 (51) 0.60 0.50 0.63 0.82 0.45 0.34 0.60
703, ASJ Max 1 (25) 0.17 0.71 0.59 0.68 0.54 0.30 0.652 (51) 0.47 0.62 1.01 0.81 0.51 0.32 0.75
705, ASJ Max 1 (25) 0.20 0.64 0.33 0.56 0.54 0.33 0.502 (51) 0.58 0.49 0.73 0.76 0.55 0.35 0.65
Values given are for design approximations only; production and test variabilities will alter results. Specific designs should be evaluated in end-use configurations.
Thermal conductivity
k, Btu•in/hr•ft2•°F λ, W/m•CMean Temperature ˚F 701 703 705, 706 Mean Temperature ˚C 701 703 705, 706
50 0.22 0.21 0.22 10 0.032 0.030 0.03275 0.24 0.23 0.23 25 0.035 0.033 0.034
100 0.26 0.24 0.25 50 0.040 0.036 0.037150 0.30 0.27 0.27 75 0.045 0.040 0.041200 0.35 0.30 0.30 100 0.052 0.045 0.045250 0.40 0.34 0.33 125 0.059 0.050 0.049300 0.46 0.38 0.37 150 0.067 0.055 0.053
700 Series Fiberglas ™ Insulation
Up
to 4
8”
Up to 96”
Up to 48”
Up
to 2
4”U
p to
48”
Up to 96”
Up
to 4
8”
Up to 96”
Up to 48”
Up
to 2
4”U
p to
48”
Up to 96”
Ceilings: 703 and 705 Series insulationInstallation instructions
703 and 705 Series recommended impaling pin patterns
Pins should be located 3-8" from the edges of the board.
Walls: 703 and 705 Series insulation
Up
to 4
8”
Up to 96”
Up to 48”
Up
to 2
4”U
p to
48”
Up to 96”
28
STANDARDS & CODES COMPLIANCE• ASTM C553, Mineral Fiber Blanket Thermal
Insulation, Type III – Type 701
• ASTM C612, Mineral Fiber Block and Board Thermal Insulation, Types IA, IB – Types 703, 705, 706, 707
• ASTM C795, Thermal Insulation For Use Over Austenitic Stainless Steel1 (except 701)
• ASTM C1136, Flexible Low Permeance Vapor Retarders for Thermal Insulation, Type I: ASJ Max; Type II: FRK
• Nuclear Regulatory Commission Guide 1.36, Non-Metallic Thermal Insulation1 (except 701)
• Doesn't contain the fire retardant decabrominated diphenyl ether (decaBDE)
• CAN/CGSB-51.10 – Type I, Class I – Types 703
• NFPA 90A and 90B
• California Insulation Quality Standards CA-T052
CERTIFICATIONS & SUSTAINABILITY• Certified by SCS Global Services to contain
a minimum of 53% recycled glass content, 31% pre-consumer and 22% post-consumer.
• This product’s Environmental Product Declaration (EPD) has been certified by UL Environment.
• 700 Series Fiberglas™ Insulation has received the Cradle to Cradle Products Innovation Institute’s Bronze Level Material Health Certificate
1. Preproduction qualification testing complete and on file. Chemical analysis of each production lot required for total conformance. Certification needs to be specified at time of order.
1. Boards with ASJ Max or FRK facings shall be applied with mechanical fasteners.
2. Fasteners shall not be located less than 3” (75mm) from each edge or corner and pin spacing should be no greater than 12” (300mm) on centers.
3. Pin lengths must be selected for tight fit, but avoid “oil-canning”.
4. In multi-layer applications, use faced material on the outer layer only.
5. Where a vapor retarder is required, cover pins and clips, and repair any facing tears/punctures with matching vapor sealing, pressure-sensitive patches/tape.
6. All joints should be sealed with matching pressure-sensitive tape, or glass fabric and mastic. 3” (76mm) tape for flat surfaces, or edges that are shiplapped and stapled; 5” in lieu of shiplapping.
7. For all tape and patches, seal firmly with squeegee or nylon sealing tool.
8. If applying to sheet metal duct work, all sheet metal joints must be sealed prior to insulating.
9. For vertical applications, install between furring strips, hat channels and Z-shaped furring when a finish will be applied. Exposed applications can use impaling pins or adhesive.
10. Horizontal applications should be installed using impaling pins.
11. On curtain walls, mount on impaling pins or use support clips. (Follow curtain wall manufacturer’s instructions for clearance.)
12. Masonry applications can be installed between withes, on the interior face with stick pins, or adhesive.
13. For precast concrete, use impaling pins or adhesive.
14. When using adhesive or impaling pins, follow manufacturers’ recommendations for surface preparation and use.
15. Product should be kept dry during shipping, storage and installation.
700 Series Fiberglas ™ Insulation
AVERAGE 53% RECYCLED CONTENT31% PRE-CONSUMER
22% POST-CONSUMER
29Insul-Quick ® Fiberglas ™ Insulation
DESCRIPTIONLightweight, semi-rigid Fiberglas™ board insulation that is easy to handle and install. It can be used with operating temperatures up to 850°F.
APPLICATION/USEIt’s a great option where an outside facing of metal or metal mesh with a finishing cement, is required. It can also be used as insulation in a metal panel system.
• Breechings
• Ducts
• Power and process boilers
Insul-Quick® Fiberglas™ InsulationInsul-Quick® Fiberglas™ Insulation provides a low thermal conductivity and high compressive strength.
FEATURES & BENEFITS• Resists crumbling and breaking during installation
• Large boards help reduce the number of joints and speed installation
Physical property dataProperty Value Test Method
Hot Surface Performance Up to 850°F (454°C)Maximum thickness 6" (152mm)
Up to 650°F (343°C)Maximum thickness 8" (203mm)
ASTM C411
Compressive Strength at 10% Deformation at 20% Deformation
90 lb/ft2 (4309 Pa)130 lb/ft2 (6225 Pa)
ASTM C165
Nominal Density 3.0 pcf (48 kg/m3) ASTM C303
Water Vapor Sorption < 2.0% by weight, at 120°F (49°C), 95% R.H. ASTM C1104
Shot Content Negligible ASTM C1335
Composite Surface Burning Characteristics1Flame Spread: 25
Smoke Developed: 50UL 723, ASTM E84or CAN/ULC-S102
1. The surface burning characteristics of these products have been determined in accordance with UL 723, ASTM E84 or CAN/ULC-S102. This standard should be used to measure and describe the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating.
SPECIFICATIONS
• Precipitators
• Chimney liners
30
Thermal Performance, ASTM C680
Operating Temperature, ˚F (˚C)Thickness 450 (232) 550 (288) 650 (343) 750 (399) 850 (454)
in. (mm) HL ST HL ST HL ST HL ST HL ST1 (25) 106 179 154 213 213 251 285 294 372 3412 (51) 58 141 84 162 117 187 156 214 203 2453 (76) 40 125 58 141 80 159 107 180 140 2034 (102) 31 116 44 129 61 144 82 160 107 1795 (127) 25 110 36 121 50 134 66 148 86 1646 (152) 21 106 30 116 42 126 56 139 72 1537 (178) 18 103 26 112 36 121 48 1328 (203) 16 101 23 108 32 117 42 127
The above table provides approximate heat loss values (HL), Btu/hr•ft2, and Surface Temperatures (ST), ˚F, for flat surfaces. Values are based on horizontal heat flow, vertical flat surface, 80˚F ambient temperature, still air, weathered aluminum jacket. To convert heat loss values to W/m2, multiply values by 3.15. To convert surface temperatures, use the formula: °C=(°F-32) 1.8.
Insul-Quick ® Fiberglas ™ Insulation
Thermal conductivity
Mean Temperature
°F k*
Mean Temperature
°C λ*75 0.23 25 0.033
100 0.24 50 0.037
200 0.30 100 0.045
300 0.37 150 0.054
400 0.46 200 0.066
500 0.58 250 0.081
* k = Btu•in/hr•ft2•°F; λ = W/m•°CApparent thermal conductivity curve determined in accordance with ASTM Practice C1045 with data obtained by ASTM Test Method C177. Values are nominal, subject to normal testing and manufacturing tolerances.
0 200100 300 400 500Mean Temperature, ºF
0.2
0.3
0.4
0.5
0.6
Con
duct
ivity
Btu
• in/h
r• ft.2 •
ºF
Installation instructions
1. Can be installed directly on hot flat or curved surfaces.
2. Attach using welding pins or studs.
3. Pins with speed washers or studs and nuts should be installed on 12”x18” (300mmx450mm) centers.
4. The sheet metal or metal mesh is secured to the same fasteners.
5. Joints of sheet metal should be offset from the joints of the insulation.
6. Panels can be erected flush to heated surfaces or away from them and secured to buckstays or breeching and ductwork angle iron stiffeners.
7. Double-layer construction with staggered joints is recommended for temeratures over 400º F.
8. Install to a maximum of 6” (152mm) at all temperatures up to 850°F, or 8” (203mm) at temperatures not over 650°F
31Insul-Quick ® Fiberglas ™ Insulation
AvailabilityThickness Size Pieces/Pack
1” 24x48” 24
1” 24x48” 96
1” 24x48” 192
1” 36x48” 24
1” 36x48” 48
1” 36x48” 96
1.5” 24x48” 56
1.5” 36.25x48” 60
1.75” 24x48” 14
1.75” 24x48” 28
2” 24x48” 12
2” 24x48” 48
2” 24x48” 96
2” 24x48” 40
2” 36x48” 12
2” 36x48” 24
2” 36x48” 48
2” 36.25x48” 44
2” 48x96” 22
2.5” 24x48” 32
2.5” 36.25x48” 36
3” 24x48” 8
3” 24x48” 32
3” 24x48” 64
3” 24x48” 28
3” 36x48” 8
3” 36x48” 16
3” 36x48” 32
3” 36.25x48” 28
3” 36.25x48” 30
3.5” 24x48” 24
4” 24x36” 44
4” 24x48” 24
4” 24x48” 48
4” 24x48” 40
4” 24x48” 20
4” 36x48” 4
4” 36x48” 12
4” 36x48” 6
4” 36x48” 24
4” 36x49” 22
4” 48x96” 11 MTO (Made to Order). Product availability subject to change. View product guide
for details.
STANDARDS & CODES COMPLIANCE• ASTM C612, Mineral Fiber Block and Board Thermal
Insulation, Types IA, IB, II
• ASTM C795, Thermal Insulation for Use Over Austenitic Stainless Steel1
• Nuclear Regulatory Commission Guide 1.36, Non-Metallic Thermal Insulation1
• U.S. Coast Guard Approval No. 164.109, Noncombustible Materials
• CAN/CGSB-51.10–Type 1, Class 1
CERTIFICATIONS & SUSTAINABILITY• Certified by SCS Global Services to contain
a minimum of 53% recycled glass content, 31% pre-consumer and 22% post-consumer
1. Preproduction qualification testing complete and on file. Chemical analysis of each production lot required for total conformance.
AVERAGE 53% RECYCLED CONTENT31% PRE-CONSUMER
22% POST-CONSUMER
32 Fiberglas ™ SCR Insulation
DESCRIPTIONLightweight insulation board composed of inorganic Fiberglas™ bonded with a thermosetting resin.
APPLICATION/USEIt is designed specifically for use on selective catalytic reduction (SCR) units in power plants. It can also be used on other industrial equipment with operating temperatures up to 1,000°F.
• Boilers
• Ducts
Fiberglas™ SCR InsulationFiberglas™ SCR Insulation is a lightweight thermal insulation solution that helps reduce heat loss and lower operating costs.*
FEATURES & BENEFITS• Free of shot, and lighter than mineral wools with
comparable thermal performance.
• No tendency for pin-hole elongation under vibration situations.
• Large boards for fewer joints.
Physical property data
Property Value Test Method
Max Operating Temperature1,000°F (538°C)
Max thickness, 8" (203mm)ASTM C411
Nominal Density 2.8 pcf (43 kg/m3) ASTM C167
Water Vapor Sorption <2% by weight ASTM C1104
Surface Burning Characteristics1Flame Spread: <25
Smoke Developed: <50UL 723, ASTM E84,or CAN/ULC-S102
1. The surface burning characteristics of these products have been determined in accordance with UL 723, ASTM E84, or CAN/ULC-S102. These standards should be used to measure and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, the results of these tests may be used as elements of a fire risk assessment that takes into account all of the factors that are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating.
SPECIFICATIONS
• Baghouses
• Scrubbers
Thermal conductivity
Mean Temperature
°F k*
Mean Temperature
°C λ*75 .23 25 0.033
100 .24 50 0.037200 .30 100 0.045300 .37 150 0.054400 .46 200 0.066500 .58 250 0.081600 .73 300 0.098
* k = Btu•in/hr•ft2•°F; λ = W/m•°CApparent thermal conductivity curve determined in accordance with ASTM Practice C 1045 with data obtained by ASTM Test Method C177. Values are nominal, subject to normal testing and manufacturing tolerances.
*Savings vary.
33Fiberglas ™ SCR Insulation
Thermal Performance, ATSM, C680
Operating Temperature, ˚F (˚C)Thickness 450 (232) 550 (288) 650 (343) 750 (399) 850 (454)
in. (mm) HL ST HL ST HL ST HL ST HL ST2 (51) 58 141 84 1623 (76) 40 125 58 141 80 1594 (102) 31 116 44 129 61 144 82 160 107 1795 (127) 25 110 36 121 50 134 66 148 86 1646 (152) 21 106 30 116 42 126 56 139 72 1537 (178) 18 103 26 112 36 121 48 132 62 1458 (203) 16 101 23 108 32 117 42 127 55 138
The above table provides approximate heat loss values (HL) Btu/hr•ft2•°F, and Surface Temperatures (ST), °F, for flat surfaces. Values are based on horizontal heat flow, vertical flat surface, 80°F ambient temperature, still air, weathered aluminum jacket with emmitance of 0.2. To convert heat loss values to W/m2, multiply values by 3.15. To convert surface temperatures, use the formula: °C=(°F-32) 1.8.
Installation instructions1. Can be installed directly on hot flat or curved
surfaces.
2. Attach using welding pins or studs and hold in place with wire ties, metal lath or lagging
3 Pins with speed washers or studs and nuts should be installed on 12”x18” (300mmx450mm) centers.
4. The sheet metal lagging is secured to the same fasteners.
5. Joints of sheet metal should be offset from the joints of the insulation.
6. Panels can be erected flush to heated surfaces or away from them and secured to buckstays or breeching and ductwork angle iron stiffeners.
7. Install to a maximum of 8” up to 1,000°F
8. Double-layer constructions with staggered joints is recommended.
9. During initial heat-up to operating temperatures above 400°F the organic binders decompose and an acrid odor and some smoke may be given off. Make sure area is properly ventilated.
AvailabilityThickness Size Pieces/Pack
1” 24x48” 24
1.5” 24x48” 16
1.5” 24x48” 56
1.5” 36.125x48” 14
1.5” 36.125x48.25” 14
1.5” 36.25x48.25” 14
1.5” 48x96” 32
2” 24x48” 12
2” 24x48” 48
2” 24x48.25” 10
2” 36.125x48.25” 10
2” 40.25x48” 10
2” 44.125x48” 10
2” 48x96” 24
2.5” 24x48” 8
3” 24x48” 8
3” 24x48” 32
3” 36.125x48” 7
3” 36.125x48.25” 7
3” 44.125x48” 32
4” 24x48” 6
4” 48x96” 3
MTO (Made to Order). Product availability subject to change. View product guide for details.STANDARDS & CODES COMPLIANCE
• ASTM C612 Mineral Fiber Block and Board Thermal Insulation, (Types IA, IB, II and III, Category 1)
AVERAGE 53% RECYCLED CONTENT31% PRE-CONSUMER
22% POST-CONSUMER
CERTIFICATIONS & SUSTAINABILITY• Certified by SCS Global Services to contain
a minimum of 53% recycled glass content, 31% pre-consumer and 22% post-consumer.
34
DESCRIPTIONNoncombustible insulation made from Inorganic Fiberglas™ bonded with a thermosetting resin. Type I-HP is manufactured in roll form, while Type II-HP comes in batt form.
APPLICATION/USEIt is available in a variety of density and thickness combinations, making this incredibly versatile and well-suited for a variety of commercial and industrial uses with operating temperatures up to 1,000°F.
• Panel systems
• Industrial ovens
• Flexible wrap for irregular surfaces
• Metal mesh blankets (Type II-HP only)
Fiberglas™ TIW InsulationFiberglas™ TIW Insulation is available in a batt or roll. It offers a high operating temperature and the lightweight, low-density construction makes it easy to cover large areas to lower equipment operating costs.
FEATURES & BENEFITS• Easy to handle and install
• No tendency for pin-hole elongation under vibration situations
• Large batts/blankets cover areas quickly with no need to drill for studs
• Type II-HP has a higher density and is better suited for applications where more compressive resistance is needed
Physical property data
PropertyType I-HP
ValueType II-HP
ValueTest Method
Equipment Operating Temperature Range1 Up to 1,000°F (538°C) ASTM C411
Nominal Density 1.0 pcf (16 kg/m3) 2.5 pcf (40 kg/m3) ASTM C167
Shot Content Negligible ASTM C1335
Water Vapor Sorption < 2.0% by weight at 120°F (49°C), 95% R.H. ASTM C1104
Surface Burning Characteristics2Flame Spread: 25
Smoke Developed:50UL 723, ASTM E84or CAN/ULC-S102
1. Maximum allowable thickness at 1,000°F (538°C): Type I-HP - 8.5" (216mm); Type II-HP - 6" (152mm).2. The surface burning characteristics of these products have been determined in accordance with UL 723, ASTM E84 or CAN/ULC-S102. This standard should be used to measure
and describe the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating.
SPECIFICATIONS
Fiberglas ™ TIW Insulation
• Boilers
• Precipitators
35
Thermal performance, ASTM C680Operating Temperature, ˚F (˚C)
Thickness 400 (204) 600 (316) 800 (427) 1,000 (538)in. (mm) HL ST HL ST HL ST HL ST
TIW
Typ
e I-H
P
1 (25) 109 182 241 275 435 394 699 5332 (51) 61 143 136 201 249 281 409 3793 (76) 43 126 95 171 174 230 287 3054 (102) 32 116 73 153 133 201 221 2625 (127) 27 110 59 141 108 182 179 2336 (152) 22 106 49 133 91 168 151 2137 (178) 19 102 43 126 79 157 130 1988 (203) 17 99 38 121 69 150 114 186
TIW
Typ
e II-
HP
1 (25) 81 160 167 225 289 306 453 4042 (51) 45 128 92 167 159 219 251 2823 (76) 31 115 63 145 109 183 173 2294 (102) 23 107 48 131 84 162 132 1985 (127) 19 109 39 123 68 148 106 1806 (152) 16 99 33 117 57 139 89 167
The above table provides approximate heat loss values (HL), Btu/hr•ft2, and Surface Temperatures (ST), ˚F, for flat surfaces. Values are based on horizontal heat flow, vertical flat surface, 80˚F ambient temperature, still air, weathered aluminum jacket. To convert heat loss values to W/m2, multiply values by 3.15. To convert surface temperatures, use the formula: °C = (°F-32)/1.8.
Fiberglas ™ TIW Insulation
Thermal conductivity
Mean Temperature
°F k*
Mean Temperature
°C λ*
TIW
Typ
e I-H
P
75 0.26 25 0.037
100 0.28 50 0.040
200 0.38 100 0.055
300 0.52 150 0.075
400 0.68 200 0.098
500 0.86 250 0.124
600 1.06 300 0.156
TIW
Typ
e II-
HP
75 0.22 25 0.032
100 0.23 50 0.033
200 0.28 100 0.040
300 0.35 150 0.050
400 0.43 200 0.062
500 0.53 250 0.076
600 0.64 300 0.092
Installation instructions
1. Can be installed directly on hot flat or curved surfaces.
2. Attach using welding pins or studs and finish with sheet metal or metal mesh and insulating cement, then canvassed and painted.
3. Pins with speed washers or studs and nuts should be installed on 16” (400mm) maximum spacing, not more than 4” from the edge of the insulation.
4. The sheet metal lagging is secured to the same fasteners.
5. Joints of sheet metal should be offset from the joints of the insulation.
6. Install to a maximum of 8.5” (Type I-HP) and 6” (Type II-HP) up to 1,000°F
7. Double-layer constructions with staggered joints is recommended for temperatures over 400°F
36
AvailabilityProduct Style Thickness Width Length
Type I-HP Bisected Roll 1” 24” 87’
Type I-HP Bisected Roll 1” 48” 87’
Type I-HP Bisected Roll 1.5” 36” 58’
Type I-HP Bisected Roll 1.5” 48” 58’
Type I-HP Single Roll 2” 24” 87’
Type I-HP Single Roll 2” 36” 87’
Type I-HP Single Roll 2” 48” 87’
Type I-HP Single Roll 3” 48” 44’
Type I-HP Single Roll 3” 48” 50’
Type I-HP Single Roll 4” 48” 39’
Type I-HP Single Roll 4” 48” 40’
Type I-HP Single Roll 4” 48” 44’
TYPE II-HP Bisected Batt 1” 24” 48”
TYPE II-HP Bisected Batt 1.5” 24” 48”
TYPE II-HP Single Layer Loose 1.5” 48” 46.5”
TYPE II-HP Single Layer Batt 2” 24” 48”
TYPE II-HP Single Layer Roll 2.125” 72” 26’
TYPE II-HP Single Layer Roll 2.125” 72” 52’
TYPE II-HP Single Layer Batt 2.5” 24” 48”
TYPE II-HP Single Layer Batt 3” 24” 48”
TYPE II-HP Single Layer Roll 4” 24” 48”
MTO (Made to Order). Product availability subject to change. View product guide for details.
STANDARDS & CODES COMPLIANCE• ASTM C553, Mineral Fiber Blanket Thermal
Insulation, Types I, II, V – TIW Type I-HP; all types – TIW Type II-HP when specification Type VII is limited to 1,000°F maximum use temperature.
• ASTM C612, Mineral Fiber Block & Board Thermal Insulation, Types IA, II, III – TIW Type II-HP
• ASTM C795, Thermal Insulation for Use Over Austenitic Stainless Steel1
• ASTM C1139, Fibrous Glass Thermal Insulation and Sound Absorbing Blanket and Board for Military Applications, Type 1, Grade 2 – TIW Type I-HP; Type 2, Grade 2 – TIW Type II-HP
• Mil. Spec. MIL-I-22023D (Ships), Insulation Felt, Thermal and Sound Absorbing Felt, Fibrous Glass, Flexible, Types 1 & 2, Class 3 – TIW Type I-HP
• Nuclear Regulatory Commission Guide 1.36, Non-Metallic Thermal Insulation1
• U.S. Coast Guard Approval No. 164.109, Noncombustible Materials
• CAN/CGSB-51.11 – Type 1, Class 4 – Fiberglas™ TIW Types I-HP & II-HP Insulation
CERTIFICATIONS & SUSTAINABILITY• Certified by SCS Global Services to contain
a minimum of 53% recycled glass content, 31% pre-consumer and 22% post-consumer.
AVERAGE 53% RECYCLED CONTENT31% PRE-CONSUMER
22% POST-CONSUMER
1. Preproduction qualification testing complete and on file. Chemical analysis of each production lot testing required for total conformance.
Fiberglas ™ TIW Insulation
37SoftR ® Duct Wrap
DESCRIPTIONFiberglas™ blanket with a factory-applied, vapor-retarder facing, and a 2” stapling/taping flange along one edge.
APPLICATION/USEUse to insulate the exterior of commercial or residential ductwork with operating temperatures from 40°F to 250°F.
• Heating ducts
• Air conditioning ducts
• Dual-temp ducts
SoftR® Duct WrapRolled insulation that can be applied to the exterior of residential or commercial ductwork to help provide condensation control and increased comfort.
FEATURES & BENEFITS• Flexible and easy to install
• Foil Reinforced Kraft (FRK) facing is easy to clean
• Condensation control
• Increased comfort control
SPECIFICATIONSMaterial requirements to achieve installed R-value
Nominal Thickness Installed Thickness Stretch Out Dimensions, in. (mm)in. (mm) in. (mm) Round and Oval Ducts Square Ducts Rectangular Ducts
1-½ (38) 1-⅛ (29) P+9-½ (240) P+8 (205) P+7 (180)2 (51) 1-½ (38) P+12 (305) P+10 (255) P+8 (205)
2-� (56) 1-⅝ (41) P+13 (330) P+11 (280) P+8-½ (215)3 (76) 2-¼ (57) P+17 (430) P+14-½ (370) P+11-½ (290)4 (102) 3 (76) P+22 (560) P+19 (483) P+16 (406)
P = measured duct perimeter
38
Physical property data
Property Value Test Method
Operating Temperature up to 250°F (121°C) ASTM C411
Insulation Jacket Temperature Limit up to 150°F (66°C) ASTM C1136
Jacket Puncture Resistance 25 units (0.7 joules) ASTM C1136
Water Vapor Permeance 0.02 perms ASTM E96
Water Vapor Sorption <3% by weight at 120°F (49°C), 95% R.H. ASTM C1104
Fungi Resistance Meets requirements ASTM C1338
Thermal ConductivityOut-of-Package k-Valuek Btu•in/hr•ft2•°F(λ at 24°C Mean, W/m•°C)
Installed (Compressed) k-Valuek Btu•in/hr•ft2•°F(λ at 24°C Mean, W/m•°C)
Type 750.30
(0.043)
Type 750.27
(0.039)
Type 1000.27
(0.039)
Type 1000.25
(0.036)
Type 1500.25
(0.036)
Type 1500.23
(0.033)
ASTM C518
Surface Burning Characteristics1Flame Spread: 25
Smoke Developed: 50ASTM E84
1. The surface burning characteristics of these products have been determined in accordance with ASTM E 84. This standard should be used to measure and describe the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating.
SoftR ® Duct Wrap
Availability & installed R-valuesStandard roll width: 48” (1.2m)Installed R (RSI) values: When installed in accordance with recommended installation procedures, SoftR® Duct Wrap will provide installed R (RSI) values as follows:
Nominal Thickness Out-of-Package
R (RSI) Value1
Installed Thickness2Installed R
(RSI) Value1,2
Roll Lengthin. mm in. mm
TYPE 75 – 0.75 pcf (12 kg/m3)1.5 (38) 5.1 (0.90) 1-1/8 (29) 4.2 (0.74) 100’2.0 (50) 6.8 (1.17) 1-1/2 (38) 5.6 (0.98) 75’2.2 (56) 7.4 (1.30) 1-5/8 (42) 6.0 (1.06) 75’3.0 (76) 10.0 (1.76) 2-1/4 (57) 8.3 (1.46) 50’
TYPE 100 – 1.00 pcf (16 kg/m3)1.5 (38) 5.6 (0.99) 1-1/8 (29) 4.5 (0.79) 100’2.0 (51) 7.4 (1.30) 1-1/2 (38) 6.0 (1.06) 75’
TYPE 150 – 1.50 pcf (24 kg/m3)1.5 (38) 6.0 (1.06) 1-1/8 (29) 4.8 (0.85) 75’2.0 (51) 8.0 (1.41) 1-1/2 (38) 6.4 (1.13) 50’
1. hr•ft2•°F/Btu (m2•°C/W) at 75°F (24°C) mean temperature.2. Assumes 25% compression of insulation.
39
STANDARDS & CODES COMPLIANCE• NFPA 90A and 90B
• ASTM C1290, Flexible Fibrous Glass Blanket Insulation Used to Externally Insulate HVAC Ducts, Type III
• ASTM C1136, Flexible Low Permeance Vapor Retarders for Thermal Insulation, Type II (facing only)
• ASTM C553* Mineral Fiber Thermal Insulation: Type I – Fiberglas™ Duct Wrap Type 75; Type II – SOFTR® Duct Wrap FRK Types 100 and 150. (Operating temperatures to 250°F (121°C) and thermal values to 150°F (66°C) mean.*Preferred specification is ASTM C1290.
NOTE TO SPECIFIERS – Federal Specification HH-I-558B (Amendment 3), Form B (covering the duct wrap), and Federal Specification HH-B-100B (Covering the facing and CAN/CGSB-51.11), are obsolete. These are replaced by the above referenced ASTM specifications.
CERTIFICATIONS & SUSTAINABILITY• Certified by SCS Global Services to contain
a minimum of 53% recycled glass content, 31% pre-consumer and 22% post-consumer.
• Certified to meet indoor air quality standards under the GREENGUARD Indoor Air Quality Certification Program, and the GREENGUARD Gold Certification.
• SoftR® Duct Wrap has received the Cradle to Cradle Products Innovation Institute's Bronze Level Material Health Certificate.
Nominal duct wrap thickness to prevent surface condensation
The above chart is based on indoor conditions so far as wind and other factors are concerned.
Thermal conductivity
Apparent thermal conductivity curve determined in accordance with ASTM Practice C1045 with data obtained by ASTM Test Method C177. Values are nominal, subject to normal testing and manufacturing tolerances.
SoftR ® Duct Wrap
Installation instructions
1. Ensure that ducts are clean, dry and tightly sealed at joints and seams.
2. Cut to stretch-out dimensions and remove 2" of insulation from facing.
3. Install duct wrap tightly butted with facing outside. (Make sure to not excessively compress at duct corners).
4. Adjacent sections should have the 2" tape flap overlapping
5. Seams should be stapled 6" on center with outward clinching staples.
6. Seal all seams and joints with matching pressure sensitive tape or with glass fabric and mastic.
7. On rectangular ducts 24" or wider, SoftR® Duct Wrap should be secured at the bottom of the duct with mechanical fasteners to prevent sagging of insulation.
8. Where a vapor retarder is required, cover and repair any facing tears/punctures with matching vapor sealing, pressure-sensitive patches/tape.
Product should be kept dry during shipping, storage and installation. It should not be used on the inside of ducts.
AVERAGE 53% RECYCLED CONTENT31% PRE-CONSUMER
22% POST-CONSUMER
40 50 60 70 80 90
90
80
70
100
110 (43)
(38)
(32)
(27)
(21)
Ambient temperatureºF ºC
1½"(38mm)required
More than3" (75mm)required
Nonerequired
2"(51mm)required
3"(75mm)required
More than3" (75mm)required
2"(51mm)required
3"(75mm)required
25(-38)
50(10)
75(23.8)
100(37.7)
125(51.6)
150 (ºF)
(65.5) (ºC)
0.45
0.40
0.35
0.30
0.25
0.20
k, Btu•in/hr•ft2•ºF
Type 750.30
(0.043)
Type 1000.27
(0.030)
Type 1500.25
(0.036)
40 50 60 70 80 90
90
80
70
100
110 (43)
(38)
(32)
(27)
(21)
Ambient temperatureºF ºC
1½"(38mm)required
More than3" (75mm)required
Nonerequired
2"(51mm)required
3"(75mm)required
More than3" (75mm)required
2"(51mm)required
3"(75mm)required
25(-38)
50(10)
75(23.8)
100(37.7)
125(51.6)
150 (ºF)
(65.5) (ºC)
0.45
0.40
0.35
0.30
0.25
0.20
k, Btu•in/hr•ft2•ºF
Type 750.30
(0.043)
Type 1000.27
(0.030)
Type 1500.25
(0.036)
Pub. No. 10020231-C. Printed in U.S.A. January 2017.THE PINK PANTHER™ & © 1964–2017 Metro-Goldwyn-Mayer Studios Inc.All Rights Reserved. The color PINK is a registered trademark of Owens Corning. © 2017 Owens Corning. All Rights Reserved.
OWENS CORNING INSULATING SYSTEMS, LLC ONE OWENS CORNING PARKWAY TOLEDO, OHIO, USA 43659
1-800-GET-PINK® www.owenscorning.com
Disclaimer of Liability
Technical information contained herein is furnished without charge or obligation and is given and accepted at recipient’s sole risk. Because conditions of use may vary and are beyond our control, Owens Corning makes no representation about, and is not responsible or liable for the accuracy or reliability of, data associated with particular uses of any product described herein.
SCS Global Services provides independent verification of recycled content in building materials and verifies recycled content claims made by manufacturers. For more information, visit www.SCSglobalservices.com.
GREENGUARD Certified products are certified to GREENGUARD standards for low chemical emissions into indoor air during product usage. For more information, visit ul.com/gg.
Owens Corning delivers high-performance residential and commercial building and industrial insulation solutions through a full line of fiberglass, foam and mineral wool products and systems. These products and system solutions help conserve energy, improve acoustics and ease installation and use.
Owens Corning applies the principles of building science to develop safe, sustainable, durable, efficient and affordable solutions that address thermal, air, and moisture performance for the entire building envelope.
• Owens Corning is the most recognized brand in the insulation industry thanks to our long history and proven reputation.
• Owens Corning has the building materials expertise to help you succeed. Whether leading building science initiatives or taking an active role in code and standard updates – we have the experience to help.
• Our belief in proven product performance quality and stewardship shows in our commitment to testing and doing the right thing.
• We are dedicated to the insulation market and the depth and breadth of our product portfolio shows that. You’ll find fiberglass, mineral wool, and XPS all under one roof.
• Our support extends to fast, reliable, transparent and flexible replenishment. From designing solutions that are channel/market specific to portals, end-to-end supply chain visibility and more.
Learn more at www.owenscorning.com