153 Caledonian Railway Cables www.caledonian-cables.co.uk Pigtail Rail Connection Cables to SE260L Applications These connection cables are designed for use in signalling equipment rooms. Standards SE260 UNE 21123 Construction Conductors: Stranded plain copper conductors to IEC 60228 class 2 or 5. Insulation: FRPVC. Outer sheath: FRPVC. Optional Limited re hazard pigtail rail connection cables: Stranded tinned copper conductors, LSZH composite insulation. Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.6 Maximum DC Conductor Resistance Ω/km 1.15/1.16* Voltage Rating KV 0.6/1.0 *For LSZH cable Mechanical and Thermal Properties Minimum Bending Radius: 7.5×OD Temperature Range: -25to +85(during operation); -10to +70(during installation) Dimensions and Weight Cable Code No. of cores& Nominal Conductor Cross Sectional Area No.×mm² No. & Nominal Diameter of Strands No/mm Nominal Insulation Thickness mm Nominal Sheath Thickness mm Nominal Overall Diameter mm Nominal Weight kg/km RF260-VV-K-0.6/1KV-1G16 1×16 19/1.04 0.7 1.4 10.3 249 RF260-RZ1-K-0.6/1KV-1G16 1×16 19/1.04 0.7 1.4 10.3 255 K is changed to U if the stranding class is changed from class 5 to class 2 Stranded Copper Conductor FRPVC/LSZH Insulation FRPVC/LSZH Sheath PVC Sheath Flame Retardant NF C32-070-2.1(C2) IEC 60332-1/EN 50265-2-1 LSZH Sheath Flame Retardant NF C32-070-2.1(C2) IEC 60332-1/EN 50265-2-1 NF C32-070-2.2(C1) IEC 60332-3/EN50266 Fire Retardant Zero Halogen IEC 60754-1/NF C20-454 EN 50267-2-1 Zero Low Smoke Emission IEC 61034/NFC20-902 EN 50268/NF C32-073 EN 50267-2-2/NF C32-074 IEC 60754-2/NF C20-453 Low Corrosivity Low Toxicity RAILFEEDER RAILWAY POWER & CONTROL CABLES UK NETWORK RAIL Standard

Upload: others

Post on 11-Nov-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Pigtail Rail Connection Cables to SE260L-railway cables ... · Pigtail Rail Connection Cables to SE260L Applications These connection cables are designed for use in signalling equipment

153

Caledonian Railway Cableswww.caledonian-cables.co.uk

Pigtail Rail Connection Cables to SE260L

Applications These connection cables are designed for use in signalling equipment rooms.

Standards SE260 ●UNE 21123 ●

Construction Conductors: Stranded plain copper conductors to IEC ●

60228 class 2 or 5. Insulation: FRPVC. ●Outer sheath: FRPVC. ●

Optional Limited fi re hazard pigtail rail connection cables: Stranded tinned copper conductors, LSZH composite insulation.

Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.6Maximum DC Conductor Resistance Ω/km 1.15/1.16*Voltage Rating KV 0.6/1.0

*For LSZH cable

Mechanical and Thermal Properties Minimum Bending Radius: 7.5×OD ●Temperature Range: -25℃ to +85℃ (during operation); ●

-10℃ to +70℃ (during installation)

Dimensions and Weight

Cable Code

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

No. & Nominal Diameter of

StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Sheath

Thicknessmm

Nominal Overall

Diametermm

Nominal Weightkg/km

RF260-VV-K-0.6/1KV-1G16 1×16 19/1.04 0.7 1.4 10.3 249RF260-RZ1-K-0.6/1KV-1G16 1×16 19/1.04 0.7 1.4 10.3 255

K is changed to U if the stranding class is changed from class 5 to class 2

Stranded Copper Conductor

FRPVC/LSZH Insulation

FRPVC/LSZH Sheath

PVC Sheath

Flame RetardantNF C32-070-2.1(C2)

IEC 60332-1/EN 50265-2-1

LSZH Sheath

Flame RetardantNF C32-070-2.1(C2)

IEC 60332-1/EN 50265-2-1NF C32-070-2.2(C1)

IEC 60332-3/EN50266

Fire Retardant Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Zero

Low Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity Low Toxicity

RAILFEEDER RAILWAY POWER & CONTROL CABLES

UK NETWORK RAIL Standard