pica (california office) 3445 kashiwa street torrance, ca ... · pica (california office) 3445...

70
PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager [email protected] c. 412-999-4783

Upload: others

Post on 20-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

PICA (California Office)3445 Kashiwa StreetTorrance, CA 90505 1-800-661-0127

Kristopher Embry, Regional [email protected]. 412-999-4783

Page 2: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Who is PICA/Russell NDE?

PICA is a U.S. based subsidiary to Russell NDE in:

➢ Los Angeles / San Antonio / New Orleans / Washington, D.C.

Experience: Over 30 years of R&D and condition assessment.

Leaders in the Industry: Our president, Dave Russell, was one of

the original founders of PPIC (50 yrs exp.). Our Operations

Manager, Ad Shatat, MA in Engineering Physics, is a leader in

adapting RFT for large diameter pipes (25 yrs exp.).

Standards: We have developed NDE standards for ASTM, ASME,

ASNT, EPRI and recently contributed to the AWWA/M77 Manual.

Develop / Manufacture / Deploy / Data Interpretation / Reports

Page 3: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Inspection Solutions

Prescreening:

Free Swimming

Visual:

CCTV & Laser

NDE:

Electromagnetic

Page 4: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Inspection Solutions

Prescreening:

Free Swimming

Page 5: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Pre-Screening Inspection – RECON+

<<<<<<<<2.3”>>>>>>>

Sensors On-Board

• Hydrophone (leak detection)

• Pressure

• Magnetometer

• XYZ (accelerometer and IMU)

• Temperature (not reportable)

Gross Wall Anomalies

Page 6: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

RECON+ - Leak Detection

The hydrophone identifies and quantifies a leak’s signature (amplitude

and frequency) and localizes it by combining all sensor data.

Page 7: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

RECON+ - Leak Detection

Recent project example: 4.5 miles between access points.

Page 8: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

RECON+ - Pressure Log

Page 9: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

RECON+ - Pressure Log

Page 10: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

RECON+ - Magnetic Log

Page 11: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

RECON+ - Magnetic Log

RECON+ gross defect results compared to MFL results

Page 12: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

RECON+ - Geolocation (X, Y, Z)

• Accelerometer and Gyroscope on board measure Pitch & Yaw Deflections without need for above ground markers. This is correlated to known locations of construction fittings and client As-built information

• More accurate when mounted on a soft foam pig.

Page 13: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

RECON+ - Extraction

Extraction plans and devices

Page 14: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

RECON+ - Advantages

Simple!

Fast!

Flexible!

Disruptive!

Page 15: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Inspection Solutions

Visual:

CCTV and Laser

Page 16: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Visual and Laser Scans

• Dedicated potable water equipment.

Page 17: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Visual and Laser Scans

• Laser Profilometry (Triangulation with CCTV)

• Lidar (Ranging)

Page 18: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Visual and Laser Scans

• Spalled liner identification/measurement

• Identify/measurement of ovality and deflection

Page 19: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Inspection Solutions

NDE/NDT:

Electromagnetics

Page 20: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Lines of Magnetic Flux

Field disturbances due to

PipeCrossSection

Probe Travel Direction

local wall loss

Near FieldZone

TransitionZone

RemoteFieldZone

Pipe

Exciter

Energy Flow Path

Receiver

Liner

NDE - Electromagnetic Basics

Page 21: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Where wall is thinner the signal arrives faster and is larger in amplitude

+V

-V

Sig

nal

Am

pli

tud

e [

Vo

lts]

Time →

Exciter Output

Flaw Signal

Signal

Nom Signal

Electromagnetic RFT – Basis of Measurement

Page 22: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

22

Electromagnetic Remote Field

Page 23: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

SeeSnake Line of Tools

3” to 78” ID Capable

Page 24: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

PICA’s NDE - Electromagnetics

Electromagnetic tools were developed to condition assess metallic pipelines and assets.

Two Methods of Data Collection

In-Line Tools External Tools

3”-78” Capable Tools >6” Capable Tools

Page 25: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Typical ‘SeeSnake’ Tool

Page 26: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

1. Tethered (dual and single tether)

2. Free Swimming

3. Manned Entry

Types of Tool Deployments

Page 27: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Tethered

Single Tether Connection to Tool

Double Tether Connection to

Tool (at each end)

Range: 6,000’

Maximum bends 270 degrees

Tethered Tool Deployments

Page 28: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Single Tether Inspection

Hydrant Launch Tethered

Single Tether Connection to Tool

Range: 6,000’

Maximum bends 270 degrees

Page 29: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Untethered or ‘Free Swimming’

Full Bore Access Required

No Maximum bends (no capstan effect)

Launch Assembly Required

Range: 20+ Miles

Monitored by on-grade TPM

Untethered Inspection

Page 30: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Typical Pig Launch Assembly

Page 31: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Manned Entry

Tool is pushed/pulled by tech

Often works in conjunction with

tethered deployment

Manned Tool Deployments

Page 32: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Pre-Cleaning – Non-Contact

This pipe is clean enough to inspect!

Page 33: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Ensure Success – Test Disc

Aluminum Body with fingers at tool circumference.

Page 34: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

High Resolution Data• Scans every 1/10” over entire

circumference

Page 35: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

0.253-inch nominal

0.253-inch nominal

0.222-inch nominal

High Resolution Results

Primary Area at 1982.6:

6”x5” corrosion

area

100% Wall Loss.

Secondary Area:

1” diameter

100% Wall Loss.

6-inches upstream

of the large

corrosion patch

Page 36: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Accuracy Determined

36

• Industry Standard Unity Plot

compares the RFT predicted depth

(vertical axis) to the known or

measured (dig verification UT) depth

(horizontal axis).

• Depth tolerances are +/-20% with

85% confidence, which is comparable

to oil & gas inspection technologies.

• Data in the graph on the right is based

on data for defects at or above the

TOD.

• Defects below the TOD (2” dia x 25%)

are still detected.

Page 37: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

External EM RFT ‘Bracelet’ Probe

Page 38: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

External EM Validation

Validate findings on-site with a UT gauge.

Page 39: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

External Probe Results

Page 40: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

How Can PICA Help?

Actionable Data:

Repair? Replace? Where?

Pre-Screening:

Narrow down the areas of concern.

Higher Accuracy:

Locate AND size defects

Family owned, small business.

We’re a SBA standard/SBE.

We are client centric.

We are data diligent.

Page 41: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Case Study – Mount Pleasant, SC

Background:

Mount Pleasant, SC (suburb of Charleston)

Services 70,000 people

~458 miles of wastewater pipe

Average Capacity of 6.35 MGD

Page 42: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Case Study – Mount Pleasant, SC

4,200 feet of DI. Section 1: 2,940; Section 2: 1,35516” DIP: Class 50; .34” WT2 – 45 degree bends; 2 – 22.5 degree bends

Client assumed areas with past failures were in poor condition. Better access was found upstream at Pit 1 in an area with no previous failures, thus that scope was added.

Past Failures

No Past Failures

Page 43: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Case Study – Mount Pleasant, SC

Estimated Replacement Cost: $4 million

Criticality: 25-30% of WW flow runs through this line

Page 44: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Case Study – Mount Pleasant, SC

Page 45: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Case Study – Mount Pleasant, SC

Start – 0 ft End– 4,200 ft550 ft 2,940 ft

Re

mai

nin

g W

all %

The vast majority of defects were found upstream near brackish water at the creek, but had exhibited no past failures.

Page 46: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Case Study – Mount Pleasant, SC

Through-hole indication at 42.12 feet (from start) at the 6:00 position (bottom of pipe)

Page 47: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Case Study – Mount Pleasant, SC

Page 48: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Case Study – Mount Pleasant, SC

Results:

Client replaced first 550 feet and upsized the last 2,000 feet

Cost: $1.5 million

Deferred cost: $2.5 million

Provided a better planning horizon

“So far, in the two condition assessment projects that we have used the SeeSnake, we

have spent less than 5% of the pipe replacement cost using this technology. In

return we have saved at least 65% of the pipe replacement cost by only replacing

and rehabilitating those sections of the pipe that really needed it.”

David Niesse, Engineering Manager, Mount Pleasant Waterworks.

Page 49: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Kris Embry, Regional Manager

e. [email protected]

c. 412-999-4783

“Good Decisions Start with Good Information!”

Thank you!

Page 50: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Recent Video – Vallecitos WD, CA

Link to Article/Video Online:https://www.waternewsnetwork.com/new-inspection-tool-aids-vallecitos-pipeline-assessments/

Page 51: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Appendix – Additional Information

Page 52: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Remote Field Testing Characteristics:

RFT is a non-contact technique that relies on time varying EM fields.

RFT technology is thus not limited to collecting a single parameter of information (Amplitude) but additionally collects a time differential element which is used in enhancing the depth calibration of defects.

RFT technology has been in commercial use since the late 1980’s

RFT Technology has been validated by such organizations as the EPA, EPRI, Battelle, and AWWARF.

Industry standards for applying the technology are in place (e.g. ASTM Standard Practice E-2096-00)

Will locate and quantify amount (depth) of missing metal.

Can see through internal liners & deposits.

Sensitive only to the metallic components of the pipe.

Equally sensitive to external or internal corrosion.

Page 53: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Cylinder Information Provided by PICA Inspection Tools

For every defect above the Threshold of Detection:

- Depth

- Length

Upon request, PICA will calculate the safe operating (or

rupture) pressure for the steel shell using either modified

B31G (also known as RSTRENG) or DNV-RP-F101.

Stresses working on the pipe (cylinder).

Page 54: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Inspection speeds of 15ft/min (ideal) up to 60ft/min (maximum).

Defect depth measurements within +/-20%.

Reporting of the axial (in 0.1ft) and circumferential location of wall loss indications.

The tools measure the deflection angle of mitered bends in the line, and distinguish if the bends are up/down (+/- 3 degree pitch) or left/right (+/- 5 degree yaw).

Flagging of pipes with stress loading.

Defects can be sorted on depth or B31G burst pressure calculations.

References back to AGM (grade location sensor) locations within 0.3%.

Inspection Numbers

Page 55: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Inspection Tool Launch – 24”

Page 56: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Typical Stuffing Box Installed

Page 57: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Modular to facilitate introduction through Manholes.

PICA’s PCCP Tools

36” – 48” Tool

RAFT: High Res EM In-Line

Inspection Tool

Page 58: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

RECON+ - Extraction

Page 59: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

RECON+ - Extraction

Page 60: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Wire breaks are important for the understanding the

structural integrity/strength of PCCP.

Cylinders are important as a water barrier.

If the cylinder is compromised, it could corrode the wires

and is arguably a pre-cursor to wire breaks.

PICA’s remote field tool will also detects both wire breaks

and corrosion defects

PCCP – Wire Breaks and Cylinder

Page 61: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

No Calibration Pipe Available

Use a close representative pipe sample to confirm tool is

sensitive to wall loss.

Estimate optimal tool settings based on representative pipe.

Perform a mathematical calibration and utilize histogram.

Page 62: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Calibration Process

Calibration Pipe Available?

Scan the cal pipe for a baseline.

After baselining, machine defects into the pipe.

Examples: Simplest Defect Morphology for depth sizing:

Six 25.4mm diameter, round, flat bottom holes (Depths: 20%, 40%, 50%, 60%, 80%, 100%)

Simplest Defect Morphology for volumetric sizing and determining Threshold of Detection: (Through Hole Diameters-THD) [25.4mm, 19.1mm, 12.7mm, 6.4mm, 4.8mm, 3.2mm, 1.6mm]

Scan the machined cal pipe for optimal accuracy.

No Pipe available?

Use close representative pipe sample.

Perform a mathematical calibration and utilize histogram.

Page 63: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

24-inch Calibration Example

Page 64: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

EMIT: High Res EM In-Line Inspection Tool

48” – 78” Tool

PICA’s PCCP Tools

Page 65: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Flexible and modular.

PICA’s PCCP Tools

EMIT: High Res EM In-Line Inspection Tool

Page 66: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Full Bore Access

All of our EM tools =<36” require full bore

access.

All PICA tools can pass through bends.

Butterfly and Plug valves must be removed or

avoided.

Butterfly valves in dewatered pipes, if large

enough, can be passed manually by a crew and

tool (rebuilt in pipe).

Access Requirements

Page 67: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Ongoing R&D – PCCP Inspection

Page 68: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Field Wire Break Detection

10+ broken wires in body of pipe.

Page 69: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

Cylinder Failure with Intact Wires

Page 70: PICA (California Office) 3445 Kashiwa Street Torrance, CA ... · PICA (California Office) 3445 Kashiwa Street Torrance, CA 90505 1-800-661-0127 Kristopher Embry, Regional Manager

On-Going R&D