pi0011 pievm207 pi0mt pievm107 - co.el.te · pdf filesist e m a con scam biat ore as e st e...

12
1 1 2 2 3 3 4 4 D C B B A A Title Number Revision Size A4 Date: 22/10/2015 Sheet of File: C:\Users\..\IMPIANTO rlx Pr_ 10.SchDocDrawn By: SONDA 1 SONDA 2 FLUSS SISTEMA DOPPIO IMPIANTO FUNZIONANTE A 2 TERMOSTATI PER SONDA PROGRAMMA Pr10 EvM EVM1 LINEA F N CIRC N F E.VALV N Fon Foff CIRC2/ N F AUX1 COM NA NC AUX2 P1 EvM EVM1 LINEA TC= TEMPERATURA CAMINO RELAX = CONDIZIONE IN CUI SI INTERROMPE MANUALMENTE IL RISCALDAMENTO P1 =(TC>=TP1) USCITA CIRCOLATORE CAMINO EV =(TC>=TEV) USCITA ELETTROVALVOLA SCAMBIO SANITARIO AUX1 =(S2>=TAU) USCITA TERMOSTATO AUX A CONTATTI PULITI AUX2 =(S2>=TA2) USCITA TERMOSTATO AUX2 Abilitazione uscita aux2 con funzione Grill permessa. P2 EvM EVM2 EvM EVM2 P2 IMPIANTO 2 PI0MT PI0RT CO PI06 PI07 PI0011 CO0 PI0011 PIEVM106 PIEVM107 PIEVM108 COEVM1 PIEVM106 PIEVM107 PIEVM108 PIEVM206 PIEVM207 PIEVM208 COEVM2 PIEVM206 PIEVM207 PIEVM208 PIP109 PIP1010 COP1 PIP109 PIP1010 PIP209 PIP2010 COP2 PIP209 PIP2010 PIV man?09 PIV man?010 COV man? PIV man?09 PIV man?010 PIV man?09 PIV man?010 PIV man?09 PIV man?010

Upload: phamduong

Post on 30-Jan-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PI0011 PIEVM207 PI0MT PIEVM107 - CO.EL.TE · PDF filesist e m a con scam biat ore as e st e rno con circuit o ant iconde nsa programma pr0 sca p2 ev m a f a f a f v n r t c= t e m

1

1

2

2

3

3

4

4

D D

C C

B B

A A

Title

Number RevisionSize

A4

Date: 22/10/2015 Sheet ofFile: C:\Users\..\IMPIANTO rlx Pr_ 10.SchDocDrawn By:

SONDA 1 SONDA 2FLUSS

SISTEMA DOPPIO IMPIANTO FUNZIONANTE A 2 TERMOSTATI PER SONDA

PROGRAMMA Pr10

P1

EvM

EVM1

LINEA

F N

CIRC

N F

E.VALV

N Fon

Foff

CIRC2/

N F

AUX1

CO

M

NA

NC

AUX2

P1

EvM

EVM1

LINEA

TC= TEMPERATURA CAMINORELAX = CONDIZIONE IN CUI SI INTERROMPE MANUALMENTE IL RISCALDAMENTO

P1 =(TC>=TP1) USCITA CIRCOLATORE CAMINO EV =(TC>=TEV) USCITA ELETTROVALVOLA SCAMBIO SANITARIO AUX1 =(S2>=TAU) USCITA TERMOSTATO AUX A CONTATTI PULITI AUX2 =(S2>=TA2) USCITA TERMOSTATO AUX2

Abilitazione uscita aux2 con funzione Grill permessa.

P2

EvM

EVM2

EvM

EVM2 P2

IMPIANTO 2

PI0MT

PI0RT

CO

PI06

PI07

PI0011CO0

PI0011

PIEVM106

PIEVM107

PIEVM108

COEVM1

PIEVM106

PIEVM107

PIEVM108

PIEVM206

PIEVM207

PIEVM208

COEVM2

PIEVM206

PIEVM207

PIEVM208

PIP109PIP1010

COP1

PIP109 PIP1010

PIP209 PIP2010

COP2

PIP209 PIP2010

PIV man?09 PIV man?010

COV man?

PIV man?09PIV man?010

PIV man?09PIV man?010

PIV man?09PIV man?010

Page 2: PI0011 PIEVM207 PI0MT PIEVM107 - CO.EL.TE · PDF filesist e m a con scam biat ore as e st e rno con circuit o ant iconde nsa programma pr0 sca p2 ev m a f a f a f v n r t c= t e m

1

1

2

2

3

3

4

4

D D

C C

B B

A A

Title

Number RevisionSize

A4

Date: 22/10/2015 Sheet ofFile: C:\Users\..\IMPIANTO rlx Pr0 2 - .SchDocDrawn By:

LINEA

F N

CIRC

N F

E.VALV

N Fon

Foff

CIRC2/

N F

AUX1

CO

M

NA

NC

AUX2

SONDA 1 SONDA 2FLUSS

Flux

P1

SCA

V NR

P1 P2

EvMCALDAIALINEA

SISTEMA CON SCAMBIATORE AS ESTERNO CON CIRCUITO ANTICONDENSA

PROGRAMMA Pr0

SCA

P2

EvM

AF

AF

AF

V NR

TC= TEMPERATURA CAMINORELAX = CONDIZIONE IN CUI SI INTERROMPE MANUALMENTE IL RISCALDAMENTO

P1 =(TC>=TP1) USCITA CIRCOLATORE CAMINO EV =(TC>=TEV) USCITA ELETTROVALVOLA SCAMBIO SANITARIO AUX1 =(TC>=TAU) USCITA TERMOSTATO AUX A CONTATTI PULITI AUX2 =((TC>=TA2) AND (NO RELAX) ) USCITA TERMOSTATO AUX2

Abilitazione uscita aux2 con funzione Grill non permessa.

COMANDO USCITE NELLE SITUAZIONI DISICUREZZA O DI ALLARME P1 =ACCESO EV =ACCESO AUX1 = (TC>=TAU) AUX2 = ACCESO

PI0MT

PI0RT

CO

PI06

PI07

PI0RT

PI0011

CO0

PI0011

PI0011

PI0011

PIEVM06

PIEVM07

PIEVM08

COEVM

PIEVM06

PIEVM07

PIEVM08

PIFL?06 PIFL?08

COFL?

PIP109PIP1010

COP1

PIP109PIP1010

PIP209PIP2010

COP2

PIP209PIP2010

PIV man?09PIV man?010

COV man?

PIV man?09

PIV man?010

PIV NR09PIV NR010

COV NR

PIV NR09

PIV NR010

Page 3: PI0011 PIEVM207 PI0MT PIEVM107 - CO.EL.TE · PDF filesist e m a con scam biat ore as e st e rno con circuit o ant iconde nsa programma pr0 sca p2 ev m a f a f a f v n r t c= t e m

1

1

2

2

3

3

4

4

D D

C C

B B

A A

Title

Number RevisionSize

A4

Date: 22/10/2015 Sheet ofFile: C:\Users\..\IMPIANTO rlx Pr0.SchDoc Drawn By:

LINEA

F N

CIRC

N F

E.VALV

N Fon

Foff

CIRC2/

N F

AUX1

CO

M

NA

NC

AUX2

SONDA 1 SONDA 2FLUSS

Flux

P2P1

SCA

V NR

V NR

EvM

ENTRATA ACQUA FREDDA SANITARIA

P1 P2

EvMCALDAIALINEA

SISTEMA CON SERPENTINA AS INTERNA E CIRCUITO ANTICONDENSA

PROGRAMMA Pr0

TC= TEMPERATURA CAMINORELAX = CONDIZIONE IN CUI SI INTERROMPE MANUALMENTE IL RISCALDAMENTO

P1 =(TC>=TP1) USCITA CIRCOLATORE CAMINO EV =(TC>=TEV) USCITA ELETTROVALVOLA SCAMBIO SANITARIO AUX1 =(TC>=TAU) USCITA TERMOSTATO AUX A CONTATTI PULITI AUX2 =((TC>=TA2) AND (NO RELAX) ) USCITA TERMOSTATO AUX2

Abilitazione uscita aux2 con funzione Grill non permessa.

COMANDO USCITE NELLE SITUAZIONI DISICUREZZA O DI ALLARME P1 =ACCESO EV =ACCESO AUX1 = (TC>=TAU) AUX2 = ACCESO

CO

PI0MT

PI0RT

PI06

PI07

PI0RT

PI0011

CO0

PI0011

PI0011

PIEVM06

PIEVM07

PIEVM08

COEVM

PIEVM06

PIEVM07

PIEVM08

PIFL?06 PIFL?08

COFL?

PIP109PIP1010

COP1

PIP109PIP1010

PIP209PIP2010

COP2

PIP209PIP2010

PIV man?09PIV man?010

COV man?

PIV man?09PIV man?010

PIV man?09PIV man?010

PIV man?09PIV man?010

PIV NR09

PIV NR010

COV NR

PIV NR09PIV NR010

Page 4: PI0011 PIEVM207 PI0MT PIEVM107 - CO.EL.TE · PDF filesist e m a con scam biat ore as e st e rno con circuit o ant iconde nsa programma pr0 sca p2 ev m a f a f a f v n r t c= t e m

1

1

2

2

3

3

4

4

D D

C C

B B

A A

Title

Number RevisionSize

A4

Date: 22/10/2015 Sheet ofFile: C:\Users\..\IMPIANTO rlx Pr1.SchDoc Drawn By:

LINEA

F N

CIRC

N F

E.VALV

N Fon

Foff

CIRC2/

N F

AUX1

CO

M

NA

NC

AUX2

SONDA 1 SONDA 2FLUSS

P1SCA

V NR

P1 P2

EvM

EVM1 + EVM2

CALDAIALINEA

SISTEMA CON SCAMBIATORE AS ESTERNO CON CIRCUITO ANTICONDENSA E EV DI CHIUSURA RISCALDAMENTO

PROGRAMMA Pr1

SCA

EvM

EVM2

AF

AF

V NR

EvM

EVM1

P2

FluxAF

nota questa modalità non prevede funzionamento del tasto relax

TC= TEMPERATURA CAMINOFLUSS= FLUSSOSTATO ACQUA SANITARIA (NORMAL APERTO)

P1 =((TC>=TP1) OR (EV ON)) USCITA CIRCOLATORE CAMINO EV =((TC>=TEV) AND (FLUSS)) USCITA ELETTROVALVOLA SCAMBIO SANITARIO AUX1 =(TC>=TAU) USCITA TERMOSTATO AUX A CONTATTI PULITI AUX2 =((TC>=TA2) AND (EV OFF) ) USCITA TERMOSTATO AUX2

Abilitazione uscita aux2 con funzione Grill non permessa.

COMANDO USCITE NELLE SITUAZIONI DISICUREZZA O DI ALLARME P1 =ACCESO EV =((TC>=TEV) AND (FLUSS)) AUX1 = (TC>=TAU) AUX2 = ACCESO

PI0MT

PI0RT

CO

PI06

PI07

PI0RT

PI0011

CO0

PI0011

PI0011

PI0011

PIEVM106

PIEVM107

PIEVM108

COEVM1

PIEVM1 0 EVM206

PIEVM1 0 EVM207

PIEVM1 0 EVM208

COEVM1 0 EVM2

PIEVM206

PIEVM207

PIEVM208

COEVM2

PIFL?06 PIFL?08

COFL?

PIP109PIP1010

COP1

PIP109

PIP1010PIP209

PIP2010

COP2

PIP209PIP2010

PIV man?09PIV man?010

COV man?

PIV man?09PIV man?010PIV man?09PIV man?010

PIV man?09

PIV man?010

PIV NR09PIV NR010

COV NR

PIV NR09

PIV NR010

Page 5: PI0011 PIEVM207 PI0MT PIEVM107 - CO.EL.TE · PDF filesist e m a con scam biat ore as e st e rno con circuit o ant iconde nsa programma pr0 sca p2 ev m a f a f a f v n r t c= t e m

1

1

2

2

3

3

4

4

D D

C C

B B

A A

Title

Number RevisionSize

A4

Date: 22/10/2015 Sheet ofFile: C:\Users\..\IMPIANTO rlx Pr2.SchDoc Drawn By:

LINEA

F N

CIRC

N F

E.VALV

N Fon

Foff

CIRC2/

N F

AUX1

CO

M

NA

NC

AUX2

SONDA 1 SONDA 2FLUSS

P2

SCA

V NR

P2

EvM CALDAIA

LINEA

SISTEMA CON SERPENTINA AS INTERNA E ABILITAZIONE OPZIONALE FUNZIONE GRILL

PROGRAMMA Pr2

EvM

AF

AF

V NR

P1

FluxAF

GRILLP1

TC= TEMPERATURA CAMINORELAX = CONDIZIONE IN CUI SI INTERROMPE MANUALMENTE IL RISCALDAMENTO

P1 =((TC>=TP1)AND (NO RELAX)) USCITA CIRCOLATORE CAMINO EV =(TC>=TEV) USCITA ELETTROVALVOLA SCAMBIO SANITARIO AUX1 =(TC>=TAU) USCITA TERMOSTATO AUX A CONTATTI PULITI AUX2 =(TC>=TA2) USCITA TERMOSTATO AUX2

Abilitazione uscita aux2 con funzione Grill permessa.

COMANDO USCITE NELLE SITUAZIONI DISICUREZZA O DI ALLARME P1 =ACCESO EV =ACCESO AUX1 = (TC>=TAU) AUX2 = ACCESO se in funzione termostato

PI0MT

PI0RT

CO

PI06

PI07

PI08

PI06

PI07

PI0RT

PI0011

CO0

PI0011

PI0011

PIEVM1 0 EVM206

PIEVM1 0 EVM207

PIEVM1 0 EVM208

COEVM1 0 EVM2

PIFL?06 PIFL?08

COFL?

PIP109PIP1010

COP1

PIP109PIP1010

PIP209PIP2010

COP2

PIP209PIP2010PIV man?09 PIV man?010

COV man?

PIV man?09PIV man?010

PIV man?09PIV man?010

PIV man?09PIV man?010

PIV NR09PIV NR010

COV NR

PIV NR09

PIV NR010

Page 6: PI0011 PIEVM207 PI0MT PIEVM107 - CO.EL.TE · PDF filesist e m a con scam biat ore as e st e rno con circuit o ant iconde nsa programma pr0 sca p2 ev m a f a f a f v n r t c= t e m

1

1

2

2

3

3

4

4

D D

C C

B B

A A

Title

Number RevisionSize

A4

Date: 22/10/2015 Sheet ofFile: C:\Users\..\IMPIANTO rlx Pr3.SchDoc Drawn By:

SONDA 1 SONDA 2FLUSS

SCA

V NR

SISTEMA CON SCAMBIATORE AS ESTERNO E ABILITAZIONE OPZIONALE FUNZIONE GRILL

PROGRAMMA Pr3

EvM

EVM2

AF

AF

P1

AF

O GRILL

EvM

EVM1

V NR

Flux

FLUSS

LINEA

F N

CIRC

N F

E.VALV

N Fon

Foff

CIRC2/

N F

AUX1

CO

M

NA

NC

AUX2

P1

EvM

EVM1

CALDAIALINEA EvM

EVM2

TC= TEMPERATURA CAMINORELAX = CONDIZIONE IN CUI SI INTERROMPE MANUALMENTE IL RISCALDAMENTO

P1 =(TC>=TP1) USCITA CIRCOLATORE CAMINO EV =((TC>=TEV) AND( (NO FLUSS) or (NO RELAX)) USCITA ELETTROVALVOLA SCAMBIO SANITARIO AUX1 =(TC>=TAU) USCITA TERMOSTATO AUX A CONTATTI PULITI AUX2 =(TC>=TA2) USCITA TERMOSTATO AUX2

Abilitazione uscita aux2 con funzione Grill permessa.

COMANDO USCITE NELLE SITUAZIONI DISICUREZZA O DI ALLARME P1 =ACCESO EV =((TC>=TEV) AND( (NO FLUSS) or (NO RELAX)) AUX1 = (TC>=TAU) AUX2 = ACCESO se in funzione termostato

PI0MT

PI0RT

CO

PI06

PI07

PI0RT

PI0011CO0

PI0011

PI0011

PIEVM106

PIEVM107

PIEVM108

COEVM1

PIEVM106

PIEVM107

PIEVM108

PIEVM206

PIEVM207

PIEVM208

COEVM2

PIEVM206

PIEVM207

PIEVM208

PIFL?06 PIFL?08

COFL?

PIP109PIP1010

COP1

PIP109PIP1010PIV man?09 PIV man?010

COV man?

PIV man?09PIV man?010

PIV man?09PIV man?010

PIV man?09PIV man?010

PIV NR09PIV NR010

COV NR

PIV NR09

PIV NR010

Page 7: PI0011 PIEVM207 PI0MT PIEVM107 - CO.EL.TE · PDF filesist e m a con scam biat ore as e st e rno con circuit o ant iconde nsa programma pr0 sca p2 ev m a f a f a f v n r t c= t e m

1

1

2

2

3

3

4

4

D D

C C

B B

A A

Title

Number RevisionSize

A4

Date: 22/10/2015 Sheet ofFile: C:\Users\..\IMPIANTO rlx Pr4 2.SchDoc Drawn By:

LINEA

F N

CIRC

N F

E.VALV

N Fon

Foff

CIRC2/

N F

AUX1

CO

M

NA

NC

AUX2

SONDA 1 SONDA 2FLUSS

V NR

P1

EvM

EVM1

CALDAIALINEA

SISTEMA CON BOYLER ACQUA SANITARIA ESTERNO RICIRCOLO BOYLER E ABILITAZIONE OPZIONALE FUNZIONE GRILL

PROGRAMMA Pr4

AF

AF

P1

GRILL

EvM

EVM1

V NR

SONDA

AF

LINEA

F N

CIRC

N F

E.VALV

N Fon

Foff

CIRC2/

N F

AUX1

CO

M

NA

NC

AUX2

P1

EvM

EVM1

CALDAIALINEA

P2

P2

LOGICA FONZIONAMENTO

TC= Temperatura caminoTB= Temperatura boylerTEH=Impostazione temperatura max boylerTEL=Impostazione temperatura min boylerTAU=Impostazione termostato auxTP2= Impostazione termostato aux2/circ2TP1=non utilizzatoCAR_1 = Condizione in cui è attiva la fase di carico del boylerCAR_0 = Condizione in cui non è attiva la fase di carico del boyler

CAR_1 = (TB<=TEL)CAR_0 = (TB>=TEH)P1 = (CAR_1) AND (TC>TB)E.VALV= CAR uscita a contatti puliti AUX = (TC>=TAU)AUX2=(TB>=TP2)

COMANDO USCITE NELLE SITUAZIONI DISICUREZZA O DI ALLARME P1 =ACCESO EV =ACCESO AUX1 = (TC>=TAU) AUX2 = ACCESO se in funzione termostato

PI0MT

PI0RT

PI0SONDA

PI0SONDA 3

PI0SONDA 4

CO

PI0MT

PI0RT

PI06

PI07

PI0RT

PI0011CO0

PI0011

PI0011

PIEVM106

PIEVM107

PIEVM108

COEVM1

PIEVM106

PIEVM107

PIEVM108

PIEVM106

PIEVM107

PIEVM108 PIP109PIP1010

COP1

PIP109PIP1010

PIP109PIP1010 PIP209 PIP2010

COP2

PIP209

PIP2010

PIV man?09 PIV man?010

COV man?

PIV man?09PIV man?010

PIV man?09PIV man?010

PIV man?09PIV man?010

PIV NR09PIV NR010

COV NR

PIV NR09

PIV NR010

Page 8: PI0011 PIEVM207 PI0MT PIEVM107 - CO.EL.TE · PDF filesist e m a con scam biat ore as e st e rno con circuit o ant iconde nsa programma pr0 sca p2 ev m a f a f a f v n r t c= t e m

1

1

2

2

3

3

4

4

D D

C C

B B

A A

Title

Number RevisionSize

A4

Date: 22/10/2015 Sheet ofFile: C:\Users\..\IMPIANTO rlx Pr4.SchDoc Drawn By:

LINEA

F N

CIRC

N F

E.VALV

N Fon

Foff

CIRC2/

N F

AUX1

CO

M

NA

NC

AUX2

SONDA 1 SONDA 2FLUSS

V NR

P1

EvM

EVM1

CALDAIALINEA

SISTEMA CON BOYLER ACQUA SANITARIA ESTERNO E ABILITAZIONE OPZIONALE FUNZIONE GRILL

PROGRAMMA Pr4

EvM

EVM2

AF

AF

P1

GRILL

EvM

EVM1

V NR

SONDA

AF

LINEA

F N

CIRC

N F

E.VALV

N Fon

Foff

CIRC2/

N F

AUX1

CO

M

NA

NC

AUX2

P1

EvM

EVM1

CALDAIALINEA EvM

EVM2

LOGICA FONZIONAMENTO

TC= Temperatura caminoTB= Temperatura boylerTEH=Impostazione temperatura max boylerTEL=Impostazione temperatura min boylerTAU=Impostazione termostato auxTP2= Impostazione termostato aux2/circ2TP1=non utilizzatoCAR_1 = Condizione in cui è attiva la fase di carico del boylerCAR_0 = Condizione in cui non è attiva la fase di carico del boyler

CAR_1 = (TB<=TEL)CAR_0 = (TB>=TEH)P1 = (CAR_1) AND (TC>TB)E.VALV= CAR uscita a contatti puliti AUX = (TC>=TAU)AUX2=(TB>=TP2)

COMANDO USCITE NELLE SITUAZIONI DISICUREZZA O DI ALLARME P1 =ACCESO EV =ACCESO AUX1 = (TC>=TAU) AUX2 = ACCESO se in funzione termostato

PI0MT

PI0RT

PI0SONDA

PI0SONDA 3

PI0SONDA 4

CO

PI0MT

PI0RT

PI06

PI07

PI0RT

PI0011CO0

PI0011

PI0011

PIEVM106

PIEVM107

PIEVM108

COEVM1

PIEVM106

PIEVM107

PIEVM108

PIEVM106

PIEVM107

PIEVM108PIEVM206

PIEVM207

PIEVM208

COEVM2

PIEVM206

PIEVM207

PIEVM208

PIP109PIP1010

COP1

PIP109PIP1010

PIP109PIP1010

PIV man?09 PIV man?010

COV man?

PIV man?09PIV man?010

PIV man?09PIV man?010

PIV man?09PIV man?010

PIV NR09PIV NR010

COV NR

PIV NR09

PIV NR010

Page 9: PI0011 PIEVM207 PI0MT PIEVM107 - CO.EL.TE · PDF filesist e m a con scam biat ore as e st e rno con circuit o ant iconde nsa programma pr0 sca p2 ev m a f a f a f v n r t c= t e m

1

1

2

2

3

3

4

4

D D

C C

B B

A A

Title

Number RevisionSize

A4

Date: 22/10/2015 Sheet ofFile: C:\Users\..\IMPIANTO rlx Pr5.SchDoc Drawn By:

SONDA 1SONDA 2FLUSS

SISTEMA GESTIONE COLLETTORE SOLARE A CIRCOLAZIONE FORZATA

PROGRAMMA Pr5

EvM

EVM1

AF

AF

SONDA

AF

LINEA

F N

CIRC

N F

E.VALV

N Fon

Foff

CIRC2/

N F

AUX1

CO

M

NA

NC

AUX2

P1

EvM

EVM1

LINEA

SONDA 2

P1

USCITE DISPONIBILI PER INTEGRAZIONI

TC= TEMPERATURA COLLETTORETB= TEMPERATURA BOLLITORED=DELTA DIFFERENZIALE

P1 =(TC>=(TB+D)) USCITA CIRCOLATORE P1 EV =(TB>=TEV) USCITA ELETTROVALVOLA AUX1 =(TB>=TAU) USCITA TERMOSTATO AUX A CONTATTI PULITI AUX2 =(TB>=TA2) USCITA TERMOSTATO AUX2

Abilitazione uscita aux2 con funzione Grill NON permessa.

uscite Aux1 e Aux2 dipendenti da temperatura boyler

PI0MT

PI0RT

PI0SONDA

PI0SONDA 3

PI0SONDA 4

CO

PI06

PI07

PI0RT

PI0011CO0

PI0011

PIEVM106

PIEVM107

PIEVM108

COEVM1

PIEVM106

PIEVM107

PIEVM108

PIP109

PIP1010

COP1

PIP109PIP1010

PIpannello solare0SONDA 2

COpannello solare

PIV man?09 PIV man?010

COV man?

PIV man?09PIV man?010

Page 10: PI0011 PIEVM207 PI0MT PIEVM107 - CO.EL.TE · PDF filesist e m a con scam biat ore as e st e rno con circuit o ant iconde nsa programma pr0 sca p2 ev m a f a f a f v n r t c= t e m

1

1

2

2

3

3

4

4

D D

C C

B B

A A

Title

Number RevisionSize

A4

Date: 22/10/2015 Sheet ofFile: C:\Users\..\IMPIANTO rlx Pr6 fancoil.SchDocDrawn By:

LINEA

F N

CIRC

N F

E.VALV

N Fon

Foff

CIRC2/

N F

AUX1

CO

M

NA

NC

AUX2

SONDA 1 SONDA 2FLUSS

LINEA

SISTEMA CON RADIATORI FANCOIL

PROGRAMMA Pr6

P1

FANCOIL

*

FANCOIL

P1MORSETTIERA VENTILATORE FANCOIL

NEUTRO COMUNEFASE VELOCITA' 1FASE VELOCITA' 2FASE VELOCITA' 3

TS1= TEMPERATURA SONDA 1

P1 =(TS1>=TPO) USCITA CIRCOLATORE P1 EV =((TS1>=TV1) AND (NO AUX) AND( NO AUX2)) USCITA ELETTROVALVOLA AUX =((TS1>=TV2)AND( NO AUX2)) USCITA TERMOSTATO AUX A CONTATTI PULITI AUX2 =(TS1>=TV3) USCITA TERMOSTATO AUX2

Abilitazione uscita aux2 con funzione Grill NON permessa.

COMANDO USCITE NELLE SITUAZIONI DISICUREZZA O DI ALLARME P1 =ACCESO EV =SPENTO AUX1 =SPENTO AUX2 =ACCESO

PI0MT

PI0RT

CO

CO0

PI0011

PI0011

PIP109PIP1010

COP1

PIP109PIP1010PIV man?09 PIV man?010

COV man?

PIV man?09PIV man?010

Page 11: PI0011 PIEVM207 PI0MT PIEVM107 - CO.EL.TE · PDF filesist e m a con scam biat ore as e st e rno con circuit o ant iconde nsa programma pr0 sca p2 ev m a f a f a f v n r t c= t e m

1

1

2

2

3

3

4

4

D D

C C

B B

A A

Title

Number RevisionSize

A4

Date: 22/10/2015 Sheet ofFile: C:\Users\..\IMPIANTO rlx Pr7-8 th fancoil.SchDocDrawn By:

LINEA

F N

CIRC

N F

E.VALV

N Fon

Foff

CIRC2/

N F

AUX1

CO

M

NA

NC

AUX2

SONDA 1 SONDA 2FLUSS

LINEA

REGOLATORE FANCOIL TERMOSTATATO

PROGRAMMA Pr7 è Pr8

FANCOIL

*

FANCOIL

MORSETTIERA VENTILATORE FANCOIL

NEUTRO COMUNEFASE VELOCITA' 1FASE VELOCITA' 2FASE VELOCITA' 3

SONDA CONTROLLO TEMPERATURA ACQUA

SONDA AMBIENTALE

USCITA A CONTATTI PULITI CONTROLLATA DA SONDA AMBIENTE ( S2 )

Programma 7 fino a che la temperatura ambiente è inferiore a quella impostata si ha l'attivazione delle uscite per il termoconvettore, le velocità sono stabilite dalla temperatura dell'acqua di mandata mediante la sonda1.

Programma 8 l'attivazione del termoconvettore si ha quando la temperatura di mandata ha raggiunto il parametro TST(temperatura di start) e la tempearatura ambiente è inferiore al valore di impostatzione Tah .le velocità sono regolate applicando un delta in riferimento della Tah, es:Tah = 20°C Del=2° t.ambiente=20° ventola stopt_ambiente=19° ventola a velocità1 t_ambiente=18° ventola a velocità1 t_ambiente=17° ventola a velocità2 t_ambiente=16° ventola a velocità2 t_ambiente=15° ventola a velocità3 t_ambiente=14° ventola a velocità3 t_ambiente=13° ventola a velocità3

COMANDO USCITE NELLE SITUAZIONI DISICUREZZA O DI ALLARME P1 =SPENTO EV =SPENTO AUX1 =SPENTO AUX2 =ACCESO

CO0

PI0011

PI0011

Page 12: PI0011 PIEVM207 PI0MT PIEVM107 - CO.EL.TE · PDF filesist e m a con scam biat ore as e st e rno con circuit o ant iconde nsa programma pr0 sca p2 ev m a f a f a f v n r t c= t e m

1

1

2

2

3

3

4

4

D D

C C

B B

A A

Title

Number RevisionSize

A4

Date: 22/10/2015 Sheet ofFile: C:\Users\..\IMPIANTO rlx Pr9.SchDoc Drawn By:

P1 OUT CIRC

SONDA

P2 OUT AUX2EvM

EVM1 OUT EV

SONDA 1 SONDA 2FLUSS

LINEA

F N

CIRC

N F

E.VALV

N Fon

Foff

CIRC2/

N F

AUX1

CO

M

NA

NC

AUX2

EvM

EVM1

LINEA

P1 OUT CIRC

SISTEMA GESTIONE RISCALDAMENTO CON PRELIEVO DA PUFFER

FASE

NEUTRO

TC= TEMPERATURA CAMINO TB= TEMPERATURA BOYLER O PUFFER RELAX = CONDIZIONE IN CUI SI INTERROMPE MANUALMENTE IL RISCALDAMENTO

P1 =((TC>=TP1) AND(TC>TB)) USCITA CIRCOLATORE CAMINO EV =(TB>=TEV) USCITA ELETTROVALVOLA SCAMBIO SANITARIO AUX1 =(TB>=TAU) USCITA TERMOSTATO AUX A CONTATTI PULITI AUX2 =(( TB>TA2) AND (NO RELAX) ) USCITA TERMOSTATO AUX2

P2 O UT AUX2

PROGRAMMA Pr9

COMANDO USCITE NELLE SITUAZIONI DISICUREZZA O DI ALLARME P1 =(TC>=TP1) EV =(TB>=TEV) AUX1 =(TB>=TAU) AUX2 =ACCESO

PI0RTCO

PI06

PI07

PI0MT

PI0RT

PI0SONDA

PI0SONDA 3

PI0SONDA 4

PI0MT

PI0RT

PI0011CO0

PI0011

PIEVM106

PIEVM107

PIEVM108

COEVM1

PIEVM1 OUT EV06

PIEVM1 OUT EV07

PIEVM1 OUT EV08

COEVM1 OUT EV

PIP1 OUT CIRC09 PIP1 OUT CIRC010

COP1 OUT CIRC

PIP1 OUT CIRC09 PIP1 OUT CIRC010

PIP2 O UT AUX209 PIP2 O UT AUX2010

COP2 O UT AUX2

PIP2 OUT AUX209 PIP2 OUT AUX2010

COP2 OUT AUX2