photo album - waterfall bath enclosures...place the door inside the shower. 3 measure the centerline...
TRANSCRIPT
WaterSlide Installation Instructions 1
WaterSlide offers Homeowners a unique alternative to conventional hinged or pivoting Heavy Glass Doors. WaterSlide is designed to be used exclusively with 3/8” Glass.
WaterSlide may be installed in smaller bathrooms where obstructions inhibit the operation of a conventional swing door.
Slide
Slide
Slide
WaterSlide may be installed with the Sliding Panel adjacent to a Return Panel…
…or with the Sliding Panel next to the wall for easy access to the Shower Controls.
This Instruction Manual will detail the step-by-step procedures required to install this WaterSlide with a Return Panel adjacent to the Sliding Panel. Doors shown on the previous page are installed in a similar manner. WaterSlide hardware is conveniently packaged in Assemblies, note the assemblies used to install this door.
Drill Guide used to locate holes in Header for Side Attach Assembly
Wall Clips
Bottom Guide Assembly
Side Attach Assembly – 2 Required
Roller Assembly – 2 Required
WaterSlide Installation Instructions 2
Wall Mount Bracket
End Attach Assembly
Finger Pull (Other Hardware May Be
Substituted)
Slide
Tools Required: Tape Measure & Level Drill With 3/16”, 9/32” & 1/4” Bits Phillips Screw Driver Saw (To Cut Header to Length) 1.5mm & 3mm Allen Wrenches Caulking Gun & Clear Sealant
Place the Door inside the shower.
3
Measure the centerline of the unit and check all surfaces for plumb & level. Use the WaterSlide Detail Sheets to determine glass sizes and hardware required. Detail sheets are included at the end of this document.
Install the Return Panel on the centerline of the Curb.
Centerline
Before installing the Fixed Panel, mount the Dovetail Retainer for the Bottom Guide 1-1/16” inches from the inside of the In-Line Panel
Note the Inside Surface of the In-Line Panel lines up with the end of the Return Panel. Install the Fixed Panel.
Note the Clip at the top of the Fixed Panel is optional. However, the Header is easier to install with the panel held securely in place.
Clip 1-1/16”
In-Line Panel
WaterSlide Installation Instructions
Measure from the wall to the centerline of the holes in the top of the panel.
WaterSlide Installation Instructions 4
Make sure the Return Panel is plumb….
…and measure from the Return Panel to the wall. Cut the Header to this dimension.
Transfer these dimensions to the face of the header and use the drill guide to drill 9/32” Diameter Holes.
Drill a 1/4” Diameter Hole 7/16” from the end of the header
Install the End Attach Bracket with the 3/16”x1/4” screw.
Insert the Wall Mounting Bracket into the header and tighten the set screws with a 3mm Allen wrench.
Slide the two Side Mount Retainers into the header. Line up with the holes drilled in Step 6 and secure with masking tape.
Disassemble the Roller Bracket paying close attention to the orientation of the components.
Support the header with a clamp or suction cup and attach the Header Bracket to the wall with the #8 x 1-1/2” screw.
WaterSlide Installation Instructions 5
Slide the Brackets into the header with the notched hole to the exterior.
If using the plastic wall plug, drill a 3/16” Dia. Hole in the wall to attach the Wall Mount Bracket. If not using the plug, drill a 1/8” hole. Drill the hole at a 20 Deg. Angle.
Use the End Attach Bracket to secure the header to the fixed panel. Tighten with the Spanner Wrench
¼”
1-1/16”
Top of In-Line Panel 20 Deg. Angle
WaterSlide Installation Instructions 6
Insert the Spacer and Washer for the Side Attach Brackets between the Fixed Panel and the Header.
Thread the Cap Screw into the Retainers installed in Step 8 and tighten with the Spanner Wrench. Repeat for the remaining Side Attach Bracket.
Move the Door into position and support with two ½” blocks or wooden shims. Insert the Elliptical Spacer into the hole in the top of the glass with the serrated face to the exterior. Slide the Roller Bracket over the glass and line up with the Elliptical Spacer.
Hand-tighten the Exterior Cap Screw into the Interior Cap Screw. Repeat for the remaining Bracket.
Place the washer over the Interior Cap Screw and insert into the Elliptical Spacer. Be sure the slots in the Cap Screw engage the tabs on the Spacer.
Insert the Serrated Washer on the outside of the Bracket. Be sure the tabs on the Washer lock into the notches in the Bracket.
WaterSlide Installation Instructions 7
Check the door for alignment with the return panel. To adjust, place a Spanner Wrench on both the Interior and Exterior Cap Screws. Loosen the Exterior Screw slightly and rotate the Interior Cap screw to move the corner of the Door up or down to align with the Return Panel. If necessary, repeat for the remaining bracket. Once the adjustment is correct, tighten the Exterior Cap Screws with the Spanner Wrench.
Slide the Bottom Guide over the Dovetail Retainer installed in Step 3. Tighten the Set Screw with a 1.5mm Allen Wrench
Attach the Finger Pull.
Apply a thin bead of Clear Silicone Sealant around the edges of the Fixed Panel and Return Panel. Refer to the WaterSlide Detail Sheets for optional Polycarbonate Seals which may be installed on the Sliding Panel. Waterfall recommends you install a S1LB Seal on the leading edge of the Sliding Panel to avoid glass-to-glass contact with the return panel or wall. Clean your WaterSlide with a mild non-abrasive cleaner with a neutral PH.
Description Req.
A W-937 Header 1
B WB-1 Wall Mounting Bracket 2
C HD-4067 Side Attachment Assembly 2
D WA-938 Hanger Bracket Set of 2 2
E WA-941 Bottom Guide Assembly 1
F DK-112 Pull 1
A
Un
it H
eig
ht
Fixe
d P
ane
l = U
nit
He
igh
t
Slid
ing
Pan
el =
Un
it H
eig
ht
–2-1
/8”
1-5
/8”
1/2”
B
C
D
E
WaterSlide Heavy-Glass Sliding Door Wall-To-Wall Installation
9/16”
1-5/8”
1-1/4”
7/8”
Use W-940 Drill-Guide to Locate 9/32” Dia. Hole
3”
Unit Width
Fixed Panel = (Unit Width / 2) – 1/4”
Sliding Panel = (Unit Width / 2) + 2-1/4”
F
B
B
2” Optional PC-1090 Seal
Optional SDTW Seal
Optional S1LB Seal (edge of glass)
3/4” Dia. (2)
1-1/8”
3” 3”
Un
it H
eig
ht
Un
it H
eig
ht
-2-1
/8”
1-5/8”
1/2”
2”
Center
Sliding Panel Width
Panel Width ± Wall Condition
9/16” Dia. (2)
15/16”
3”
Fixed Panel Width
Panel Width ± Wall Condition
1.375
1.062
1.250
.625 Dia.
Notch Detail
Description Req.
A W-937 Header 1
B WB-1 Wall Mounting Bracket 1
C HD-4067 Side Attachment Assembly 2
D WA-938 Roller Bracket Set of 2 1
E WA-941 Bottom Guide Assembly 1
F DK-112 Pull 1
G HD-4071 End Attachment Assembly 1
Use W-940 Drill-Guide to Locate 9/32” Dia. Hole
Unit Width = Centerline -3/16”
Fixed Panel = (Unit Width / 2) – 1/4”
Sliding Panel = (Unit Width / 2) + 2-1/4”
F
B 2”
Centerline
3/16”
A
Un
it H
eig
ht
Fixe
d P
ane
l = U
nit
He
igh
t
Slid
ing
Pan
el =
Un
it H
eig
ht
–2-1
/8”
1-5
/8”
1/2”
B
C
D
E
9/16”
1-5/8”
1-1/4”
7/8”
13/16” Centerline of Unit
Ce
nte
rlin
e
7/16”
Pan
el =
Ce
nte
rlin
e +
7/1
6”
G
Optional PC-1090 Seal
Optional SDTW Seal
Optional S1LB Seal
WaterSlide Heavy-Glass Sliding Door With Fixed Panel Adjacent to Wall
Page 1 of 2
Description Req.
A W-937 Header 1
B WB-1 Wall Mounting Bracket 1
C HD-4067 Side Attachment Assembly 2
E WA-941 Bottom Guide Assembly 1
F DK-112 Pull 1
G HD-4071 End Attachment Assembly 1
** WA-939 Bumper Assembly 2
WaterSlide Heavy-Glass Sliding Door With Fixed Panel Adjacent to Wall
** Not Shown
9/16” Dia.
15/16”
1-1/16”
Return Panel Width
Return Panel Width ± Wall Condition
Un
it H
eigh
t
See Door-Only Detail for Layout of Sliding
& Fixed Panel
Page 2 of 2
Optional S1LB Seal (edge of glass)
3/4” Dia. (2)
1-1/8”
3” 3”
Un
it H
eigh
t
Un
it H
eigh
t -2
-1/8
”
1-5/8”
1/2”
Center of Glass
Sliding Panel Width
Sliding Panel Width
9/16” Dia. (2)
15/16”
3”
Fixed Panel Width
Fixed Panel Width ± Wall Condition
3”
1/2” Dia.
2”
3” 3”
6”
Un
it H
eigh
t
±
Cu
rb C
on
dit
ion
Description Req.
A W-937 Header 1
B WB-1 Wall Mounting Bracket 1
C HD-4067 Side Attachment Assembly 2
D WA-938 Roller Bracket Set of 2 1
E WA-941 Bottom Guide Assembly 1
F DK-112 Pull 1
G HD-4071 End Attachment Assembly 1
WaterSlide Heavy-Glass Sliding Door With Fixed Panel Adjacent To Return Panel
Use W-940 Drill-Guide to Locate 9/32” Dia. Hole A
Un
it H
eig
ht
Fixe
d P
ane
l = U
nit
He
igh
t
Slid
ing
Pan
el =
Un
it H
eig
ht
–2-1
/8”
1-5
/8”
1/2”
B
C
D
E
9/16”
1-5/8”
1-1/4”
7/8”
13/16” Centerline of Unit
Optional SDTW Seal
Unit Width = Centerline – 3/16”
Fixed Panel = (Unit Width / 2) + 1/8”
Sliding Panel = (Unit Width / 2) + 2-1/4”
F B
2” Optional PC-1090 Seal
3/16”
Ce
nte
rlin
e
7/16”
Pan
el =
Ce
nte
rlin
e +
7/1
6”
G
Centerline
Optional S1LB Seal Edge of Glass
Page 1 of 2
Description Req.
A W-937 Header 1
B WB-1 Wall Mounting Bracket 1
C HD-4067 Side Attachment Assembly 2
E WA-941 Bottom Guide Assembly 1
F DK-112 Pull 1
G HD-4071 End Attachment Assembly 1
** WA-939 Bumper Assembly 2
WaterSlide Heavy-Glass Sliding Door With Fixed Panel Adjacent to Return Panel
** Not Shown
9/16” Dia.
15/16”
1-1/16”
Return Panel Width
Return Panel Width ± Wall Condition
Un
it H
eigh
t See Door-Only Detail for Layout of Sliding
& Fixed Panel
Page 2 of 2
9/16” Dia. (2)
15/16”
3”
Fixed Panel Width
Fixed Panel Width
3”
Optional S1LB Seal (edge of glass)
3/4” Dia. (2)
1-1/8”
2”
3”
Un
it H
eigh
t
Un
it H
eigh
t -2
-1/8
”
1-5/8”
1/2”
Center of Glass
Sliding Panel Width
Sliding Panel Width ± Wall Condition
1/2” Dia.
3”
3” 3”
6”
Un
it H
eigh
t
±
Cu
rb C
on
dit
ion