phenix beam use proposal for runs 9-13 status of phenix

61
1 PHENIX Beam Use Proposal for Runs 9-13 Barbara Jacak for the PHENIX Collaboration Status of PHENIX & our science Beam Use Proposal Summary Spin Goals (& what it takes to get there) 200 GeV Au+Au collision goals Search for Onset of the Perfect Liquid Are b quarks stopped? Data Taking Efficiency

Upload: others

Post on 30-Nov-2021

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

1

PHENIX Beam Use Proposal for Runs 9-13

Barbara Jacakfor the PHENIX Collaboration

• Status of PHENIX & our science• Beam Use Proposal Summary

Spin Goals (& what it takes to get there)200 GeV Au+Au collision goalsSearch for Onset of the Perfect LiquidAre b quarks stopped?

• Data Taking Efficiency

Page 2: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

2

PHENIX CollaborationUniversity of São Paulo, São Paulo, BrazilAcademia Sinica, Taipei 11529, ChinaChina Institute of Atomic Energy (CIAE), Beijing, P. R. ChinaPeking University, Beijing, P. R. ChinaCharles University, Faculty of Mathematics and Physics, Ke Karlovu 3, 12116 Prague, Czech RepublicCzech Technical University, Faculty of Nuclear Sciences and Physical Engineering, Brehova 7, 11519 Prague, CzechRepublicInstitute of Physics, Academy of Sciences of the Czech Republic, Na Slovance 2, 182 21 Prague, Czech RepublicUniversity of Jyvaskyla, P.O.Box 35, FI-40014 Jyvaskyla, FinlandLaboratoire de Physique Corpusculaire (LPC), Universite de Clermont-Ferrand, F-63170 Aubiere, Clermont-Ferrand,FranceDapnia, CEA Saclay, Bat. 703, F-91191 Gif-sur-Yvette, FranceIPN-Orsay, Universite Paris Sud, CNRS-IN2P3, BP1, F-91406 Orsay, FranceLaboratoire Leprince-Ringuet, Ecole Polytechnique, CNRS-IN2P3, Route de Saclay, F-91128 Palaiseau, FranceSUBATECH, Ecòle des Mines at Nantes, F-44307 Nantes, FranceUniversity of Muenster, Muenster, GermanyKFKI Research Institute for Particle and Nuclear Physics at the Hungarian Academy of Sciences (MTA KFKI RMKI),Budapest, HungaryDebrecen University, Debrecen, HungaryEövös Loránd University (ELTE), Budapest, HungaryBanaras Hindu University, Banaras, IndiaBhabha Atomic Research Centre (BARC), Bombay, IndiaWeizmann Institute, Rehovot 76100, IsraelCenter for Nuclear Study (CNS-Tokyo), University of Tokyo, Tanashi, Tokyo 188, JapanHiroshima University, Higashi-Hiroshima 739, JapanKEK - High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801, JapanKyoto University, Kyoto, JapanNagasaki Institute of Applied Science, Nagasaki-shi, Nagasaki, JapanRIKEN, The Institute of Physical and Chemical Research, Wako, Saitama 351-0198, JapanRIKEN – BNL Research Center, Japan, located at BNLPhysics Department, Rikkyo University, 3-34-1 Nishi-Ikebukuro, Toshima, Tokyo 171-8501, JapanTokyo Institute of Technology, Oh-okayama, Meguro, Tokyo 152-8551, JapanUniversity of Tsukuba, 1-1-1 Tennodai, Tsukuba-shi Ibaraki-ken 305-8577, JapanWaseda University, Tokyo, JapanCyclotron Application Laboratory, KAERI, Seoul, South KoreaEwha Womans University, Seoul, KoreaKangnung National University, Kangnung 210-702, South KoreaKorea University, Seoul 136-701, KoreaMyong Ji University, Yongin City 449-728, KoreaSystem Electronics Laboratory, Seoul National University, Seoul, South KoreaYonsei University, Seoul 120-749, KoreaIHEP (Protvino), State Research Center of Russian Federation , Protvino 142281, RussiaJoint Institute for Nuclear Research (JINR-Dubna), Dubna, RussiaKurchatov Institute, Moscow, RussiaPNPI, Petersburg Nuclear Physics Institute, Gatchina, Leningrad region 188300, RussiaSkobeltsyn Institute of Nuclear Physics, Lomonosov Moscow State University, Vorob'evy Gory, Moscow 119992, RussiaSaint-Petersburg State Polytechnical Univiversity , Politechnicheskayastr, 29, St. Petersburg 195251, RussiaLund University, Lund, Sweden

14 Countries; 68 Institutions; 550 Participants*Abilene Christian University, Abilene, Texas, USABrookhaven National Laboratory (BNL), Chemistry Dept., Upton, NY 11973, USABrookhaven National Laboratory (BNL), Collider Accelerator Dept., Upton, NY 11973, USABrookhaven National Laboratory (BNL), Physics Dept., Upton, NY 11973, USAUniversity of California - Riverside (UCR), Riverside, CA 92521, USAUniversity of Colorado, Boulder, CO, USAColumbia University, Nevis Laboratories, Irvington, NY 10533, USAFlorida Institute of Technology, Melbourne, FL 32901, USAFlorida State University (FSU), Tallahassee, FL 32306, USAGeorgia State University (GSU), Atlanta, GA 30303, USAUniversity of Illinois Urbana-Champaign, Urbana-Champaign, IL, USAIowa State University (ISU) and Ames Laboratory, Ames, IA 50011, USALos Alamos National Laboratory (LANL), Los Alamos, NM 87545, USALawrence Livermore National Laboratory (LLNL), Livermore, CA 94550, USAUniversity of Maryland, College Park, MD 20742, USADepartment of Physics, University of Massachusetts, Amherst, MA 01003-9337, USAOld Dominion University, Norfolk, VA 23529, USAUniversity of New Mexico, Albuquerque, New Mexico, USANew Mexico State University, Las Cruces, New Mexico, USADepartment of Chemistry, State University of New York at Stony Brook (USB), Stony Brook, NY 11794,USADepartment of Physics and Astronomy, State University of New York at Stony Brook (USB), StonyBrook, NY 11794, USAOak Ridge National Laboratory (ORNL), Oak Ridge, TN 37831, USAUniversity of Tennessee (UT), Knoxville, TN 37996, USAVanderbilt University, Nashville, TN 37235, USA

Page 3: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

3

Recent scientific accomplishments

First measurement of initial temperature at RHIC 0804.4168

Discovery of low mass dilepton excess in central Au+Au0706.3034

Quantitative analysis of energy loss 0801.1665; 0801.4020

Opacity emergence between 22.4 and 62.4 GeV √ s NN 0801.4555

Mapping the medium response to jets0801.4545; 0712.3033; PRC77, 011901(2007)

+ 8 additional papers: high pT hadron suppression, J/Ψ suppression, source imaging, dielectrons (p+p), d+Au/p+Au/n+Au, fluctuations, phi flow, ALL.

Page 4: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

4

Tinit via low mass, high pT dileptons

exp + TAA scaled pp

Fit to pp

NLO pQCD (W. Vogelsang)

T = 221 ± 23 ± 18 MeV (central)T = 224 ± 16 ± 19 MeV (MB)

arXiv: 0804.4168

Page 5: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

5

Initial temperature (with aid of models)*

Hydrodynamical models in qualitative agreement with the data: Eur.Phys.J. C46 (2006) 451

D.d’Enterria &D.Peressounko T=590MeV, τ0=0.15fm/cS. Rasanen et al. T=580MeV, τ0=0.17fm/cD. K. Srivastava T=450-600MeV, τ0=0.2fm/cS. Turbide et al. T=370MeV, τ0=0.33fm/cJ. Alam et al. T=300MeV, τ0=0.5fm/c

Tinit (MeV)

τ 0 (f

m/c

)

Tinit > Tc even for simple exponential!

* and 1 billion events …

Page 6: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

6

Quantitative Analysis of Energy Loss

Page 7: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

7

Impact

Since 2001:41 PRL’s18 Phys. Rev. C 5 Phys. Rev. D 2 Phys. Lett. B 1 Nucl. Phys. A

(White Paper) > 5700 citations

Most-cited single result from RHIC (421 citations):“Suppression of hadrons with large transverse momentum in central

Au+Au collisions at √ sNN= 130 GeV ”,K. Adcox et al. , Phys.Rev.Lett. 88:022301 (2002), nucl-ex/0109003

+ 5 other papers with > 250 citations

Cumulative PHENIX Citations

0

1000

2000

3000

4000

5000

6000

Jan-

03

Jul-

03

Jan-

04

Jul-

04

Jan-

05

Jul-

05

Jan-

06

Jul-

06

Jan-

07

Jul-

07

Jan-

08

Jul-

08

Jan-

09

Cit

ati

on

s

Page 8: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

8

PHENIX Detector Status

TOF-W(PID)

Hadron Blind,Reaction Planedetectors

Muon PistonCalorimeter (N & S)

Page 9: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

9

NCCNCC

VTX & FVTX MPCMPC

-3 -2 -1 0 1 2 3 rapidity

0

φ c

over

age

HBD

EMC

AL

EMC

AL

(i) π0 and direct γ with additional forward EM calorimeters (NCC)

(ii) heavy flavor with silicon vertex trackers (VTX, FVTX) (i)+(ii) for large acceptance γ-jet

Detector Upgrades

FY08-FY11

FY07-10; FY08-11

Page 10: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

10

PHENIX Beam Use Proposal*

* Complexity from $ uncertainty

1.2-1.4nb-1

8-10 weeks

Page 11: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

11

Driving the requested schedule

Spin ProgramProgress hampered by ~ no p+p since Run-6

→ p+p highest priority for Run-9 Physics Opportunities + Upgrades

Rare Probes with good precision in near termPlan to replace HBD by VTX (pixels) for Run-10

→ low mass e+e-: 200 GeV Au+Au run with HBDFull VTX in Run-11

→first look at b quark: 200 GeV Au+Au (or U+U) Search for onset of perfect liquid behavior

→ Au+Au from 29-62.4 GeV Milestones

First W physics in 2011 (RIKEN)Di-electrons in 0.5 < mee < 1.0 GeV in 2010

Page 12: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

12

200 GeV polarized protons - the elusive ΔG

Run-9 sensitivity for ΔGGRSV-std(x)/2 (i.e. total=0.2, or 0.1 in measured region)Sensitivity if ΔG=0

Global fits, DSSV arXiv:0804.0422

RHIC Constraint

Run-6 result

Page 13: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

13

The role of PHENIX

Run-6

status

Run-9

Projection

PHENIX will providebest constraint ifΔG is positive(in the range0.05<x<0.2)

In that case, thebest sensitivity isvia gluon-gluoninteractions - highrates at low pT.

Page 14: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

14

200 GeV p+p (65% polarization)*

~65/pb delivered21.7/pb recorded

* assumed, and projected by CAD

Run-8 ratio recorded/delivered = 0.3

Page 15: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

15

500 GeV p+p goals for Run-9

Measure backgrounds under high pT muons Test muon trigger electronics (currently being installed) Measure production cross sections

π0, γ to pT ~ 30 GeV, J/ψ, ϒ With 25 /pb can record W’s in central arm

~ 500 W+ and ~ 90 W-First look at AL with ΔAL ~ 0.05.

Estimate 4 or 5 Physics Weeks needed

Page 16: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

16

Compelling questions in Au+Au at √ sNN=200 GeV

Does J/ψ flow (final state coalescence)?J/ψ v2

How is energy deposited to/transported in the medium?γ-h correlations, h-h correlations, fate of direct γ?

Source of the low mass dileptons? Evidence for chiralsymmetry restoration?

Are b quarks stopped by the medium? How do highest energy densities differ?→ Extend sensitivity via increased integrated luminosity

Order of magnitude ∫L over existing Run-4!Collect in Run-7 + Run-9

→ Run full energy Au+Au with VTX for c,b separation→ U+U in Run-12

Page 17: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

17

Open charm flows!

PRELIMINARY Run-4Run-7

Rapp & van Hees,PRC 71, 034907 (2005)

minimum-bias

Do b’s flow too, or just charm? ANS: VTX in Run-11Does thermalized charm contribute to J/ψ?

i.e. does J/ψ flow too? ANS: Run-9 + Run-7!

Elliptic flow of non-photonic electrons

Page 18: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

18

PHENIX preliminary

J/ψ v2

J/ψ→e+e-

But we only got

0.8 nb-1 !

Page 19: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

19

Precision of J/ψ v2 measurement

This would require 1.6 nb-1 in Run-9

PHENIX would be happy with 1.4 nb-1

Page 20: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

20

Low mass dielectrons

We have 6 bins from 0.5 - 1 GeV mass

We need morelike 24 bins

arXiv:0706.3034

Page 21: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

21

Hadron Blind Detectornovel concept for e ID → Dalitz rejection

6 active panels2 side coverswith frame

2 vertical panels

window support

HV panels frame

windowless CF4 Cherenkov detector50 cm radiator lengthCsI reflective photocathodeTriple GEM with pad readout

Page 22: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

22

HBD current status

Rebuild underway at Stony BrookPrevious problems diagnosedDamaged GEMs replacedHV distribution replaces, operating point optimizedAll surfaces cleaned

Run-7 data being analyzedOnly partial coverage with functioning modulesDiagnostics, software development using electrons

identified in PHENIX central arms Performance

14 photoelectrons in Run-7Up to 25% improvement anticipated

Page 23: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

23

HBD performance study from Run-7 data

Functioning modules being analyzed, approx. order ofmagnitude improvement in S/B

e+e- no HBDinfo

After HBD cutscombinatorial

subtracted

Page 24: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

24

HBD impact in Run-9

Improves effective signal by factor 6-16

∫ L (units of Run-4)

1.2 /nb recordedimproves effectivestatistics by ≥ 25 error bars ÷ 5→ finer mass bins!

~ what’s needed

Page 25: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

25

Run-9 200 GeV/A Au+Au projection

assume efficiency factor 0.33, as in Run-8 d+Au

Run-4 0.25/nb rec.

1.2 /nb rec.

1.4/nb rec.1.75 * Run7

8 weeks → 1-1.2 times Run-7; 10 weeks → 1.75 x Run-7

Run-7

Page 26: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

26

Third Priority

After p+p and 1.4 /nb of 200 GeV Au+Au

For Run-10Lower energy runningAddress two questions

(which may not be different …)

Page 27: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

27

Onset of RHIC’s perfect liquid

Cu+Cu

Au+Au

Somewhere between 22.4 and 62.4!Where? Properties?(temperature, etc.)

Emergence of opacity

Approach to constant v2 and hydrodynamic limit?

Page 28: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

28

Onset of heavy quark energy loss?

PHENIX preliminary

62.4 GeV Au+Au

Page 29: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

29

Where is the critical end point?

M.A. Stephanov, PoS(LAT2006)024

Range accessible with RHIC withsubstantial luminosity (above√ sNN = 22 GeV

Page 30: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

30

Predicted observables of interest

Perfect liquid onset:Emergence of opacity (heavy quarks too?)Departure of v2 from hydrodynamic predictionDi-electrons for hadron modification, temperature

Critical endpoint:v2 centrality dependence, p vs. πFluctuations in Nch, baryon number

(to find susceptibility divergence)K/π, p/π ratios and their fluctuationspT fluctuations

NB: need p+p reference data!!

were investigatedAt CERN SPS

Page 31: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

31

What does it take to do this well?

, K/pi fluctuations

To do this well need 50M events at least! 300M for charm, J/ψ (at higher √ s ) 300M for pi,p v2 vs. centralityMUST also take p+p, d+Au comparison data!

Measure multiple signals with good statistical and systematic precision make a significant improvement over existing SPS results

Page 32: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

32

The problem

+ technical challenges in triggering, timing,rejection of beam-gas interactions at thelowest energies(solving these is cheaper, but not free)

Page 33: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

33

Run time required grows for low energy

Lower energies offer insufficient bang per operations buck without very substantial luminosity increase & vertex tightening

Run-10 plan assuming 200 GeV Au+Au in Run-8

Page 34: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

34

U+U for increased energy density: Run-12

Conditions bridge between RHIC Au+Au and LHC

Energy density ~60% more than central Au+AuControl the geometryOrientations differ by ~15%

in dN/dy

η

ε 0

ε

Heinz & Kuhlman, PRL94, 132301(2005)& PRC72, 037901 (2005)

Page 35: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

35

Summary of proposal for Run 9-13

Q500p+p13

25-QvariousAu+Au

N25-N

200200

U+Up+p12

25-M500p+p

M200Au+Au11

2.515

62.4,39,28, 22.462.4, 39. 28

p+pAu+Au

25 pb-125 pb-15 or 10500/200p+p10

25 pb-1

56 pb-1

25/25 pb-1

1.2-1.4 nb-1

10 or 5~10

200 or 500200

p+pAu+Au9

p+pEquiv.

∫ L dt(recorded)

PHYSICSWEEKS

√ s NN

(GeV)SPECIESRUN

Page 36: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

36

Concluding Remarks

Running Priorities for Run-9 + Run-10:1) Constrain ΔG from positive side with π0, charged π and/or First look at 500 GeV p+p2) Low mass dileptons at 200 GeV Au+Au3) Onset/critical point scan between 22.4 and 62.4 GeV

Au+Au

Running Priorities for Run-11 + Run-12: *1) Heavy Quark separation with vertex detector in full

energy Au+Au2) W asymmetry measurement with 500 GeV p+p3) Increase energy density using U+U collisions

* top priority is not necessarily finishing the first list

Page 37: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

37

Data Taking Efficiency

PHENIX response to S&T review charge

Page 38: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

38Black vertical lines are markers forMaintenance and/or APEX days

200 GeV p+p• Live Time – 89%• PHENIX up – 69%• Overall (w/o vertex) – 62%(where 10% correction for loss dueto CNI measurements is made)

Vertex eff ~50% in both cases!• will be improved by StochasticCooling (SC) & RF advances• but vertex detector upgradesuse ±10 cm so even with SC canexpect only 38% eff!!

200 GeV d+Au• Live Time – 89%• PHENIX up – 77%• Overall (w/o vertex) – 68%

Page 39: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

39

Recorded/Delivered Luminosity Ratio

σBBCeff σZDC

eff

dAu 2.26 b x 88% 0.52 b

pp 42 mb x 53% 0.31 mb

AuAu 9.8 b x 92% ?

εPHENIX LT

dAu 68% 89%

pp 62% 89%

AuAu* 65% 90%

The useful delivered luminosity is the fractionwithin zvtx = ±30 cm, about 50% of what CAquotes

The recorded and delivered luminosity come fromthe BBC and ZDC, respectively; and their ratiowith a small loss due to livetime (LT), gives thePHENIX efficiency

Uncertainty is from σZDC & what fraction of nZDCto count (stable beam at beginning of store, notduring CNI measurements, etc)

Wide

BBC

cm

BBCvtxNN

30±=!

vtx

eff

ZDCZDC

eff

BBC

cm

BBCPHENIX

n

LTn

!"

"!

#

#=

± )( 30

* Last two weeks of Run7 AuAu

εPHENIX * εVTX = 0.68 * 0.5 = 0.34

Page 40: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

40

Run control improvements

Extensive DAQ development in Run7 →≈ 5 khz rate (AuAu)

•Run8 “easy” with up to 7 khz dAu event ratesImprovements for Run8:• zero-suppression• front-end (FPGA) data compression• upgrade HV control –reliable turn-on & off

Improvements planned for Run9 → 7 khz pp event rate• faster recovery from timing glitches• improved buffer-box disks for local data storage• fix recurring small problems, especially in event builder• improve HV control & reliability• explore clock stabilization through ramps & dumps• faster RHIC work/improved communication with us

collimation & background cleanup at beginning of storefaster dump at endfaster polarization measurements

Run7 AuAu

Page 41: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

41

In Run 4, 7, 9 PHENIX takes ~ ALL Au+Au collisions In the future (RHIC-II): luminosity goes up

PHENIX event size also increases→ Need to upgrade DAQ & Trigger accordingly

PHENIX DAQ efficiency

Fraction of presentedcollisions recordedWhile DAQ is running

Page 42: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

42

DAQ/Trigger Upgrade Plan

$500-700KReal Time TriggerAnalysis Farm

Purchase

~$185KUpgrade EVB machines

Manpower,planning, $

De-multiplex FEE

~$625KUpgrade EVB switch(10 Gb/s)

~$700KFaster DCM-II

~$200-400KUpgrade Local Level 1trigger

Development

~$2M?EMCAL FEE bettertrigger match/rejection

Replace

Page 43: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

43

backup slides

Page 44: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

44

PHENIX data sets

Page 45: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

45

NSAC performance measures

Page 46: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

46

RXNP: 2x better reaction plane resolution

equivalent to x4 statistics

charged multiplicity in RXN (a.u.)

< co

s 2(Φ

sout

h - Φ

nort

h ) >

inner + outer combinedinner segmentsouter segments

< sin 2(ΔΦ) >

BBC r.p. ~ 0.08

Page 47: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

47

J/ψ pT spectrum precision

Page 48: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

48

Direct photons – suppressed or not?

Current result w/ 10x Run4 Stats.

PHENIX Preliminary

Page 49: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

49

Inmprove pT range & errors

current

Run-7 + 9

Run-7 alone

Page 50: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

50

0

50

100

150

200

250

300

350

400

Authors

Ru

n-1

Ru

n-3

Ru

n-5

Ru

n-7

Ru

n-9

Ru

n-

11

P

F

R

GT

GS

Run

PHENIX is, and will remain, strong

1 119753

Run

Page 51: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

51

a closer look

Page 52: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

52

VirtualPhotonMeasurement

CaseofHadrons

ObviouslyS=0atMee>MhadronCaseofdirectγ*–IfpT2>>Mee2

Possibletoseparatehadrondecaycomponentsfromrealsignalinthepropermasswindow.

Anysourceofrealγcanemitγ*withverylowmass.Relationbetweentheγ*yieldandrealphotonyieldisknown.

!"

#SdN

MM

m

M

m

dM

Nd

eeee

e

ee

e

ee

121

41

3

2

2

2

2

22

$$%

&''(

)+*=

S:Processdependentfactor

( )3

2

22

21 !!

"

#$$%

&'=

hadron

ee

ee

M

MMFS

1=S

Eq. (1)

Page 53: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

53

Comparison of hydro models to photons

Page 54: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

54

dielectron spectrum vs. hadronic cocktail

Page 55: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

55

MEASURE the hadron cocktail ingredients!

Page 56: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

56

R.Rapp, Phys.Lett. B 473 (2000)R.Rapp, Phys.Rev.C 63 (2001)R.Rapp, nucl/th/0204003

low mass enhancement at150 < mee < 750 MeV3.4±0.2(stat.) ±1.3(syst.)±0.7(model)

Comparison with conventional theory

calculations: min bias Au+Authey include:QGP thermal radiationchiral symmetry restoration

Page 57: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

57

direct γ – jet coincidence: calibrated jet probe

current result Run 7 + 9 (+8)

Page 58: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

58

Toward quantifying η/S

PHENIX preliminary data

Curves fromRomatschke & Romatschke, arXiv:0706.1522

Page 59: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

59

Charged pions sensitive to sign of ΔG

q+g dominates for pT > 5 GeV/c, ALL ~ linear with ΔG

Page 60: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX

60

What about b quarks?

PRL 98, 172301 (2007)

e± from heavy flavor

b quark contribution tosingle electrons becomessignificant. do they alsolose energy?

Page 61: PHENIX Beam Use Proposal for Runs 9-13 Status of PHENIX