phase delivery over ptp unaware networks

34
Nir Laufer , Director Product Line Management ITSF 2015 Phase Delivery over PTP Unaware Networks

Upload: adva-optical-networking

Post on 12-Apr-2017

582 views

Category:

Technology


0 download

TRANSCRIPT

Nir Laufer , Director Product Line Management

ITSF 2015

Phase Delivery over PTP Unaware Networks

© 2014 ADVA Optical Networking. All rights reserved. Confidential.2

Phase Delivery Challenges in Brownfield Deployments

• Existing network introduce high level of asymmetry and PDV

• The asymmetry and PDV varies over time

• Existing networks include different transport technologies

• Upgrading/forklifting the existing NE to Sync-E/BC is very costly

Do we really need frequency and phase in the core network?

© 2014 ADVA Optical Networking. All rights reserved. Confidential.3

Bypass the problem:Get the Grand Master closer to the Slave

Core/Mobile Backhaul Provider

Mobile Network Operator

High PDV/ Asymmetry

PTPSlave Clock

Slave

4G Base Station / Small Cell

Grand

Master

GNSS

The Solution

© 2014 ADVA Optical Networking. All rights reserved. Confidential.4

Grand

Master

GNSS

Core/Mobile Backhaul Provider

Mobile Network Operator

High PDV/ Asymmetry

PTPSlave Clock

Slave

4G Base Station / Small Cell

Packet-Based Backhaul Network

Grand

Master

GNSS

Bypass the problem:Get the Grand Master closer to the Slave

The Solution

© 2014 ADVA Optical Networking. All rights reserved. Confidential.5

Phase Delivery: Small Scale GM & G.8275.1 – Last Mile

• G.8275.1 – Uses hop by hop , Ethernet multicast

mini-GM

LocalMacro Base Station

GNSS

T-SC

Core/Mobile Backhaul Provider

Mobile Network Operator

High PDV/ Asymmetry

Packet-Based Backhaul Network

PTPSlave Clock

Slave

Each network element needs to bePTP-aware (T-BC) with Sync-E

BC& Sync-E

BC& Sync-E

BC& Sync-E 4G Base Station /

Small Cell

16ppb & +/-1.1us

Ethernet Multicast

G.8275.1

Last mile full on path supportSmall Scale GM as a head of G.8275.1 chain

© 2014 ADVA Optical Networking. All rights reserved. Confidential.6

Phase Delivery: Small Scale GM & G.8275.2 – Last Mile

• G.8275.2 – Uses IP unicast for phase delivery over last mile

mini-GM

LocalMacro Base Station

GNSS

T-SC

Core/Mobile Backhaul Provider

Mobile Network Operator

High PDV/ Asymmetry

Packet-Based Backhaul Network

PTPSlave Clock

Slave

4G Base Station / Small Cell

16ppb & +/-1.1us

G.8275.2

Small Scale GM as a head of G.8275.2 chain

? Slave

Slave

© 2014 ADVA Optical Networking. All rights reserved. Confidential.7

PDV of a single NE

• Single congestion point

Two types of traffic loads have been considered:• Case A: The size of the data traffic packets was variable,

from 64 bytes to 1518 bytes• Case B: All the data traffic packets have a 1518 bytes fixed

size

Source - France Télécom Orange

© 2014 ADVA Optical Networking. All rights reserved. Confidential.8

PDV of a single NE – Case A

1Gbps, variable size data traffic:

Source - France Télécom Orange

© 2014 ADVA Optical Networking. All rights reserved. Confidential.9

PDV of a single NE – Case B

1Gbps, 1518 bytes data traffic::

Source - France Télécom Orange

© 2014 ADVA Optical Networking. All rights reserved. Confidential.10

Setup #1

Tester

Traffic Analyzer

DUT #1 DUT #2

PTP flow

Disturbance traffic

PTP GMPTP TS &Probe

Clk+1pps

pps

Reference PRTC

GPS splitter

ppsTraffic Generator

Congestion point

© 2014 ADVA Optical Networking. All rights reserved. Confidential.11

Test 1: G.8261 Traffic model #1

• Single Congestion , VLAN Priority

• PTP - 64 packets per second (on both directions)

• Single congestion point (on forward)

• Forward load traffic (no load on reverse direction)

• 80% -minimum size packets (64 octets)

• 15% - maximum size packets (1518 octets)

• 5% - medium size packets (576 octets)

© 2014 ADVA Optical Networking. All rights reserved. Confidential.12

Test #1 - Forward & Reverse Filtered Packet TIE (Tester)

• Window size – 200 sec , 0.3%

100%90%

80%70%60%50%40%30%20%10%

800

400

TIE

(nsec)

© 2014 ADVA Optical Networking. All rights reserved. Confidential.13

Test #1 – Probe Measured Forward Delay

• Window size – 5sec , Lucky packet

10%-100% 100%-10%

25265

TE(n

sec)

26505

© 2014 ADVA Optical Networking. All rights reserved. Confidential.14

Test #1 – Probe Measured Reverse Delay

• Window size – 5sec , Lucky packet

10%-100% (Fr) 100%-10% (Fr)

25308

TE(n

sec)

25612

© 2014 ADVA Optical Networking. All rights reserved. Confidential.15

Test #1 – Probe Measured Asymmetry

• Window size – 5sec , Lucky packet

10%-100% 100%-10%

-370

TE(n

sec)

296

© 2014 ADVA Optical Networking. All rights reserved. Confidential.16

Test #1 – 1PPS TE (Tester)

• Time Error within +/- 150nsec – well within +/- 1100nsec

-15

01

00

TE (

nsec)

© 2014 ADVA Optical Networking. All rights reserved. Confidential.17

Test #1 – 1PPS TE Probe Vs ref PRTC• Time Error within +/- 150nsec – well within +/- 1100nsec

-196

TE(n

sec)

56

© 2014 ADVA Optical Networking. All rights reserved. Confidential.18

Test #1 – 1PPS MTIE (Tester)

• MTIE well under G.8271.1 network limits mask

© 2014 ADVA Optical Networking. All rights reserved. Confidential.19

Test #1 – 1PPS MTIE Probe Vs Ref PRTC• MTIE well under G.823 pdh mask

© 2014 ADVA Optical Networking. All rights reserved. Confidential.20

• Single Congestion , VLAN Priority

• PTP - 64 packets per second (on both directions)

• Single congestion point (on forward)

• Forward load traffic (no load on reverse direction)

• 30% -minimum size packets (64 octets)

• 60% - maximum size packets (1518 octets)

• 10% - medium size packets (576 octets)

Test 2: G.8261 Traffic model #2

© 2014 ADVA Optical Networking. All rights reserved. Confidential.21

Test #2 - Forward & Reverse Filtered Packet TIE (Tester)

• Window size – 200 sec , 0.3%

100%90%

80%70%60%50%40%30%20%10%

630

720

TIE

(nsec)

360

© 2014 ADVA Optical Networking. All rights reserved. Confidential.22

Test #2 – 1PPS TE (Tester)

• Time Error within +/- 200nsec – well within +/- 1100nsec

60

TE (

nsec)

-180

© 2014 ADVA Optical Networking. All rights reserved. Confidential.23

Test #2 – 1PPS MTIE (Tester)

• MTIE well under G.8271.1 network limits mask

© 2014 ADVA Optical Networking. All rights reserved. Confidential.24

Setup #2

Tester

Traffic Analyzer

DUT #1 DUT #2

PTP flow

Disturbance traffic

PTP GMPTP TS &Probe

Clk+1pps

pps

Reference PRTC

GPS splitter

ppsTraffic Generator

Congestion point

DUT #3

© 2014 ADVA Optical Networking. All rights reserved. Confidential.25

Test 3: G.8261 Traffic model #1

• Two Congestion points , VLAN Priority

• PTP - 64 packets per second (on both directions)

• Single congestion point (on forward)

• Forward load traffic (no load on reverse direction)

• 60% -minimum size packets (64 octets)

• 15% - maximum size packets (1518 octets)

• 5% - medium size packets (576 octets)

© 2014 ADVA Optical Networking. All rights reserved. Confidential.26

Test #3 - Forward & Reverse Filtered Packet TIE (Tester)

• Window size – 200 sec , 0.3%

100%90%

80%70%60%50%40%30%20%10%

2000

12000

TIE

(nsec)8000

© 2014 ADVA Optical Networking. All rights reserved. Confidential.27

Test #3 – 1PPS TE (Tester)

• Time Error within +/- 250nsec – well within +/- 1100nsec

-60

240

TE(n

sec)

6000

© 2014 ADVA Optical Networking. All rights reserved. Confidential.28

Test #3 – 1PPS MTIE (Tester)

• MTIE well under G.8271.1 network limits mask

© 2014 ADVA Optical Networking. All rights reserved. Confidential.29

Other Access Technologies

• WDM/GPON/DSLAM/MW tend to include high level of PDV & Asymmetry

• In most cases would require on path support (BC/TC) in order to deliver accurate phase

• Highly dependent on the vendor implementation – Sync Survey is recommended

mini-GM

GNSS

Core/Mobile Backhaul Provider

Mobile Network Operator

High PDV/ Asymmetry

Slave

MW+TC

Slave

Slave

BC/TC

© 2014 ADVA Optical Networking. All rights reserved. Confidential.30

GPON

• GPON G.984.3 include mechanism for Time of Day distribution over G-PON –interworking with PTP is still being developed but some proprietary solutions are already proposed

• Very accurate phase delivery can be achieved

mini-GM

GNSS

Slave

Probe

Time Error below 500 nsec

GNSS

© 2014 ADVA Optical Networking. All rights reserved. Confidential.31

Microwave

• Highly dependent on the MW implementation

• PTP should be assigned to the highest QoS flow – can help reduce asymmetry and PDV caused by adaptive modulation

• Proprietary BC/TC implementations are availableGPS

Transport unit Transport unit

PTP Slave & Probe

Grand Master

GPS

Network asymmetry of 14usec over single MW hop

Vendor A

© 2014 ADVA Optical Networking. All rights reserved. Confidential.32

Microwave –Cont

GPS

Transport unit Transport unit

PTP Slave & Probe

Grand Master

GPS

Vendor B

Slave recovered clock within +/-250nsec

© 2014 ADVA Optical Networking. All rights reserved. Confidential.33

Phase Delivery over PTP unaware networks

• Phase delivery over PTP unaware network elements is possible with the following network engineering guidelines:

• Conduct Sync Survey - Test your access network elements PDV and asymmetry under realistic load scenario

• Use QoS to prioritize PTP packets

• Avoid speed mismatch (or compensate for known asymmetry

generated by the mismatch)

• Avoid network traffic utilization above 90%

• If needed , use PTP aware network element for access technologies (MW/WDM/DSLAM/GPON)

[email protected]

Questions? Thank you!

IMPORTANT NOTICE

The content of this presentation is strictly confidential. ADVA Optical Networking is the exclusive owner or licensee of the content, material, and information in this presentation. Any reproduction, publication or reprint, in whole or in part, is strictly prohibited.

The information in this presentation may not be accurate, complete or up to date, and is provided without warranties or representations of any kind, either express or implied. ADVA Optical Networking shall not be responsible for and disclaims any liability for any loss or damages, including without limitation, direct, indirect, incidental, consequential and special damages, alleged to have been caused by or in connection with using and/or relying on the information contained in this presentation.

Copyright © for the entire content of this presentation: ADVA Optical Networking.