Page 1: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

KIM LIGHTINGCVR1

PARKING STRUCTURE

PGL5SERIES

U n i v e r s a l P a r k i n g G a r a g e L u m i n a i r e

PGL5

Page 2: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

30"

60"

A

B

C

PGL5

Today’s parking garage illuminationguidelines involve both horizontal and verticalfootcandles up to 60" above the floor.Sources: IES Illuminating Engineering Society

NPA National Parking Association

Level A – IES recommendation: At 60" above the floor,minimum maintained vertical illumination should be:

Basic 0.5FcRamps - Day 1.0Fc

Night 0.5FcEntrance Areas - Day 25Fc

Night 0.5FcStairways 1.0Fc

Level B – NPA recommendation: At 30" above the floor,minimum maintained horizontal illumination should be:

Interior Parking and Driving Areas 6FcMin. at Perimeters or Vehicle Restraints 2FcSurface and Roof Parking Areas 2FcVehicle Entrances 40FcVehicle Exits 20FcStairways and Exits 20FcAverage to Minimum Illumination 3:1

Level C – IES recommendation: Minimum maintainedillumination on the floor should be:

Basic 1.0FcRamps - Day 2.0Fc

Night 1.0FcEntrance Areas - Day 50Fc

Night 1.0FcStairways 2.0Fc

SITE / AREAPARKING STRUCTURE

ROADWAYARCHITECTURAL FLOOD

ACCENTLANDSCAPE

MAILING ADDRESS:P.O. BOX 60080

CITY OF INDUSTRY, CA91716-0080

BUSINESS ADDRESS:16555 EAST GALE AVENUE

CITY OF INDUSTRY, CA 91745U.S.A.

PHONE 626 / 968 - 5666FAX 626 / 369 - 2695

ENTIRE CONTENTS © COPYRIGHT 2012 KIM LIGHTING INC.

ALL RIGHTS RESERVEDREPRODUCTION IN WHOLE OR IN PART

WITHOUT PERMISSION IS STRICTLY PROHIBITED.PATENTS PENDING

www.kimlighting.com

Printed in U.S.A.5502712282

Version 3 (10/12)

AdaptabilityThe PGL5 is available in 8 basic light patterns for completeapplication flexibility.

Ceilings – While no specific recommendationsexist for ceilings, it is widely accepted thatceilings must be well lighted to eliminate theinsecure feeling of entering a dark, cave-likestructure. To accomplish this, between 12%-15%of the luminaire’s output must be projected upward.

A Universal ParkingGarage Luminaire

Since Kim Lighting invented the first true Parking GarageLuminaire in 1988, we havecontinuously refined, reinvented,and redefined the art of parkinggarage lighting. The PGL5 isKim’s fourth generation ofparking garage luminaires, andactually combines all the featuresof the first three generationsinto one incredible lightinginstrument.

The PGL5 not only improves theapplication flexibility of theprevious models, it is easier toinstall and maintain. No matterwhat the lighting criteria:Horizontal Illumination, VerticalIllumination, Cutoff, or LightTrespass, the PGL5 canprovide the solution. Simplystated, the PGL5 makes allother parking garage luminairesobsolete.

Table of Contents

Optical Configurations 2-3

Durability 4

Installation and Maintenance 5

Ordering Information 6-7

Specifications 8

Lamp and Electrical Guide 9

Photometrics (System) 10-16

Related Products 18

Other Applications 19

Other Kim Parking Garage 20Luminaires

Application Engineering Services 21

Page 3: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

KIM LIGHTING 1

Kim Speed Mount

Hangs the fixture allowing bothhands for field wiring.

Electrical Housing

Die-cast aluminum with integralno-tool latches. Magnetic orelectronic ballasts.

Upper Reflector

Hydroformed aluminum withspecular finish. No-tool attachmentto electrical housing.

Reflector Modules

Specular aluminum panels.Available in up-light or restrictedup-light configurations.

Primary Refractor

Injection molded polycarbonate.No-tool hinging and latching toelectrical housing.

Optional Refractor

Injection molded UV stabilizedacrylic. No-tool hinging andlatching to electrical housing.

Page 4: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

2 KIM LIGHTING

8 Basic Optical Configurations

Driving Direction

UPLIGHT NO INTERNAL

REFLECTORSDOWNLIGHT

PGL51 - no internal reflectors, moderatecutoff, up-light, and vertical fill.

Driving Direction

UPLIGHT

4 INTERNALDOWN-LIGHT REFLECTORS

DOWNLIGHT

Perspective view of light patternsoriented to driving direction.

Plan view anddescription offixture opticalconfiguration.

Plan views ofUp and Downlight patterns.

Two-way drive laneDouble fixture row

One-way drive laneSingle fixture row

UPLIGHT

4 INTERNALDOWN-LIGHTREFLECTORS

DOWNLIGHT

Driving Direction

PGL52 - full internal reflectors, square lightpattern, sharp cutoff, and up-light.

PGL52R - same as PGL52, no up-light,and increased down-light.

Two-way drive laneDouble fixture row

One-way drive laneSingle fixture row

PGL51

PGL52

UPLIGHT

2 INTERNALDOWN-LIGHT REFLECTORS

DOWNLIGHT

Driving Direction

PGL53 - two internal reflectors, rectangularlight pattern, cutoff, up-light, and vertical fill.

PGL53R - same as PGL53, restricted up-light, and increased down-light.

Two-way drive laneSingle fixture row

One-way drive laneSingle fixture row

PGL53

Fixture Icons Plan Views Elevations

Fixture Icon

Page 5: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

KIM LIGHTING 3

Driving Direction

UPLIGHT

2 INTERNALDOWN-LIGHTREFLECTORS

DOWNLIGHT

With Houseside Shield

WithoutHouseside Shield

GarageGaragePerimeterPerimeterGarage

Perimeter

PGL58 - two internal reflectors, asymmetriclight pattern, cutoff, up-light, and vertical fill.

PGL58R - same as PGL58, restricted up-light, and increased down-light.

Two-way drive laneDouble fixture row

One-way drive laneSingle fixture row

PGL58

Driving Direction

UPLIGHT

2 INTERNALDOWN-LIGHTREFLECTORS

DOWNLIGHT

With Houseside Shield

WithoutHouseside Shield

GarageGaragePerimeterPerimeterGarage

Perimeter

PGL57 - two internal reflectors, asymmetriclight pattern, cutoff, up-light, and vertical fill.

PGL57R - same as PGL57, restricted up-light, and increased down-light.

Two-way drive laneDouble fixture row

One-way drive laneSingle fixture row

PGL57

One-WayDriving Direction

Without Houseside Shield

UPLIGHT

2 INTERNALDOWN-LIGHTREFLECTORS

DOWNLIGHT

With Houseside Shield

PGL56 - two internal reflectors, asymmetric lightpattern, cutoff, up-light, and vertical fill.

PGL56R - same as PGL56, restricted up-light, and increased down-light.

Optional HousesideShield Substantiallyreduces light beyondone mounting heightbehind fixture.

One-way drive laneSingle fixture row

PGL56

NO UP LIGHT

4 INTERNALDOWN-LIGHT REFLECTORS

DOWNLIGHT

Garage entrance orhigh ceiling area.

PGL55

DrivingDirection

DrivingDirection

UPLIGHT

2 INTERNALDOWN-LIGHT REFLECTORS

DOWNLIGHT

PGL54 - two internal reflectors, rectangularlight pattern, cutoff, up-light, and vertical fill.

PGL55 - full internal reflectors, full cutoff,intense down light, and no up-light.

PGL54R - same as PGL54, restricted up-light, and increased down light.

Two-way drive laneSingle fixture row

One-way drive laneSingle fixture row

PGL54

Page 6: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

4 KIM LIGHTING

Durability

Hydroformed UpperReflectorThe top reflector is one-piecehydroformed aluminum to obtaina smooth and precise reflectingsurface. The reflector is finishedwith the same vacuum metalizingprocess as the die-cast reflectormodules.

Die-Cast AluminumHousing and SpecularAluminum ReflectorModulesThe electrical housing is die-cast aluminum using a low-copper content alloy formaximum corrosion resistance.The modular reflector modules arestamped specular aluminumpanels.

Totally Sealed OpticsParking garages are openstructures allowing outside airand moisture to enter. In addition,vehicle exhaust constantlyattacks the fixture. If any ofthese contaminants penetratethe luminaire, light output willsteadily decrease as the opticalcomponents become coatedwith a film of pollutants.

The PGL5 is totally sealed with an IP66 rating. A one-pieceextruded silicone gasket, withthe ends fused together to forma continuous piece, seals therefractor to the electrical housing.At the fixture top, wire penetrationsare sealed by a silicone grommet.

Eight Stage Finish 1. Power wash in a potassium

hydroxide solution at 100°F.

2. Clear water rinse bath.

3. Iron phosphate conversioncoating at 90°F.

4. Clear water rinse bath ambient temperature.

5. Sealer bath.

6. Dry off oven.

7. Powder coating, 2.5 milnominal thickness.

8. Bake for 15 minutes at 400°F.

Aluminum

Iron PhosphateConversionCoating

Powder Coat

••

Injection Molded RefractorsPrecision light control results fromthe sharp prisms produced byinjection molding. The standardmaterial is polycarbonate.Polycarbonate reduces lensyellowing and stabilizes within thefirst 100 hours of operation, andoffers significantly greater impactand vandal resistance during thelife of the lens. Optional refractormaterial is UV stabilized acrylic.

Page 7: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

Fast Installation and Maintenance

KIM LIGHTING 5

CleaningBecause parking garages are open structures, fixtures will eventuallybecome dirty with air and exhaust pollutants. With large numbers offixtures in most garages, it is simply not practical or cost effective tohand clean the luminaires. The PGL5 is rated to IP66, allowing powerwashing; a fast and effective way to keep the fixtures at peakefficiency through regular maintenance.

Speed MountThe Kim speed mount attachesto the junction box, which canbe flush with the ceiling, or surface mounted. Thespeed mount is labeled withthe “Driving Direction” clearlyindicated so the fixture will becorrectly oriented in the garagefor the selected light pattern.

Optional Balanced Pendant J-Box and Bird Shroud (PB2)Pendant installations pose two problems that are solved by thisoption. First, the fixture must be balanced to hang vertical. Second,the fixture top should not provide a place for birds to nest.Constructed of die-cast aluminum, the PB2 utilizes the Kim speedmount for rapid fixture mounting and provides an aesthetic andfunctional solution for pendant installations.

Fixture Wiring andMountingWith the fixture suspended bythe speed mount, both handscan be used for making fieldwire connections. Final mountingis made by simply sliding thefixture onto the speed mount,which engages an anti-theftfixture-locking device.

Lamp and Ballast AccessThe PGL5 has two no-toolaccess latches on the electricalhousing. Both latches are openedto lower the refractor, but oneside stays fixed as the hinge.The refractor then swings downfor easy access to the lamp. Ifaccess to the ballast is required,the upper reflector is removedthrough keyhole slots byloosening two no-tool fasteners.

Page 8: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

Driving Direction

Driving Direction

UPLIGHT 2 INTERNAL

DOWN-LIGHT REFLECTORS

DOWNLIGHT

NO UP LIGHT 4 INTERNALDOWN-LIGHT REFLECTORS

DOWNLIGHT

One-WayDriving Direction

WithoutHousesideShield

UPLIGHT

2 INTERNALDOWN-LIGHTREFLECTORSDOWN

LIGHT With Houseside Shield

GarageGaragePerimeterPerimeterGaragePerimeter

Driving Direction

UPLIGHT 2 INTERNAL

DOWN-LIGHTREFLECTORS

DOWNLIGHT

WithHousesideShield

WithoutHousesideShield

With Houseside Shield Without HousesideShieldDriving Direction

UPLIGHT 2 INTERNAL

DOWN-LIGHTREFLECTORS

DOWNLIGHT

GarageGaragePerimeterPerimeterGaragePerimeter

Driving Direction

UPLIGHT 2 INTERNAL

DOWN-LIGHT REFLECTORS

DOWNLIGHT

UPLIGHT 4 INTERNAL

DOWN-LIGHTREFLECTORS

DOWNLIGHT

Driving Direction

Driving Direction

UPLIGHT NO INTERNAL

REFLECTORSDOWNLIGHT

6 KIM LIGHTING

Ordering Information

PGL5

Ordering Example:

Fixture Electrical Module Options

PGL56/150PMH277/ G12 / QS / A / TS / SF / PB2 / HS1 2 3-11

1 Fixture:See pages 2 and 3 forapplication reference.

PGL51 Series

PGL52 Series

PGL53 Series

PGL54 Series

PGL55 Series

PGL56 Series

PGL57 Series

PGL58 Series

PGL51

n/a

PGL52

PGL52R

PGL53

PGL53R

PGL54

PGL54R

n/a

PGL55R

PGL56

PGL56R

PGL57

PGL57R

PGL58

PGL58R

• • • • • •

• • • • • •

• • • • • •

• • • • • •

• • • • • •

• • • • • •

• • • • • •

• • • • • •

• • • • • •

• • • • • •

• • • • • •

• • • • • •

• • • • • •

• • • • • •

100H

PS

150H

PS

100P

MH

150P

MH

175P

MH

200P

MH

Fixture with Full Uplight

Fixture withRestricted Uplight

Lamp Mode Availability (•) See page 7

Page 9: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

Cat. No.: A Injection molded UV stabilized acrylic having the same prism design and optical characteristics as the standard Lexan® SLX. However, the overall depth is 1K" greater than the standard refractor,and increases the luminaire efficiency by +6.5%.

Cat. No.: QS Integral current sensing relay energizes a T-4 mini-can socket during lamp warm-up andafter power interruption. Socket de-energizes prior to the HID lamp reaching fullbrightness. T-4 mini-can halogen lamp by others; 100 Watt maximum. NOTE: Input ampswill increase by .80 with this option.

KIM LIGHTING 7

9 Optional HousesideShield:

7 Optional BalancedPendant Junction Boxand Bird Shroud:

6 Optional Fusing:

5 Optional Tamper-Resistant Latches:

3 Optional StandbyLamping:Cat. No.: QS or PLS

2 Electrical Module:HPS = High Pressure SodiumPMH = Pulse Start Metal Halide

10 Lamp Included: To order fixture with lamp included and installed, add “Lamp Included” suffix to catalog number. Will alsoinclude QS and PLS lamp when these options are specified.

Cat. No.: PB2 Die-cast aluminum, finished to match the fixture electrical housing.Offset L" NPT pendant entry to balance fixture in free-swinginginstallation. The Kim speed mount is furnished for fixture attachmentto the PB2. This option is shipped separate from fixture.

Cat. No.: TB2 One-piece cast aluminum fixture mount utilizes the standard Kimspeed mount for fixture attachment, and also serves as a junction boxfor field wire connections. Top of fixture mount casting has K" N.P.T. to receive conduit from ceiling junction box. (ceiling junctionbox and conduit to fixture by others.) Upper trunnion section is 1K" aluminum bar with adjustable mounting positions in 1" increments.Suspends fixture from 8K" to 13K" below the ceiling, as measured tothe fixture top. Finished to match fixture electrical housing.

Cat. No.: HS Fabricated from aluminum sheet, and designed to cut off directlamp light approximately one mounting-height behind the fixture.Attaches to bottom edge of the die-cast reflectors.

8 Optional TrunnionMount:

4 Optional AcrylicRefractor:

Single Fuse

Line Volts: 120V 208V 240V 277V 347V 480V

Cat. No.: SF DF DF SF SF DF

100HPS120 150HPS120 100PMH120 150PMH120 175PMH120 200PMH120100HPS208 150HPS208 100PMH208 150PMH208 175PMH208 200PMH208100HPS240 150HPS240 100PMH240 150PMH240 175PMH240 200PMH240100HPS277 150HPS277 100PMH277 150PMH277 175PMH277 200PMH277100HPS347 150HPS347 100PMH347 150PMH347 175PMH347 200PMH347100HPS480 150HPS480 100PMH480 150PMH480 175PMH480 200PMH480

CAUTION: All manufacturers of metal halide lamps recommend turning them off for 15 minutes once per week when under continuous operation. This will reduce the risk of arc tube rupture at end of life. Also, color temperature may differ between manufacturers of metal halide lamps. See lamp manufacturer’sspecification sheets.

Quartz Standby

Acrylic Refractor

Tamper-ResistantLatch

Balanced PendantJunction Box and Bird Shroud

Trunnion Mount

Cat. No.: TS Stainless steel captive hex socket (Allen) shoulder screws securelatches in locked position.

Available only on:

PGL56 SeriesPGL57 SeriesPGL58 Series

Cat. No.: PLS Integral current sensing relay energizes an integral fluorescent ballast during lamp warm-up and after power interruption. Ballast de-energizes prior to the HID lampreaching full brightness. 57 Watt fluorescent lamp by others.

Fluorescent Standby

Houseside Shield

Lamp Lamp LineWatts Type Volts

100 PMH 277

Page 10: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

8 KIM LIGHTING

Specifications

PGL5 Models

Fixture with Standard Polycarbonate Refractor

Fixture with Optional Acrylic Refractor (A)

Dimensions

Fixture with Optional Balanced PendantJ-Box and Bird Shroud (PB2)

Fixture with Optional Trunnion Mount (TB2)

8J"(210 mm)

10L" DIA.(273 mm)

10" DIA.(254 mm)

18" DIA.(457 mm)

18" DIA.(457 mm)

8K" to 13K"(216 mm to 330 mm)

ADJUSTABLE MOUNTING POSITION

4"(102 mm)

4"(102 mm)

7E"(200 mm)

6K"(165 mm)

11E"(302 mm)

10K"(267 mm)

4J"(108 mm)

14E"(378 mm)

Polycarbonate

16J"(413 mm)Acrylic

Speed Mount: Electro-zinc plated steel for mounting to standard 4" junction box or mud-box. Fixture hangs from hooks to free bothhands to make field wire connections. Allows tool-free fixturemounting to junction box, with integral anti-theft lock.

Electrical Housing: Die-cast, low copper (< 0.6% Cu) aluminum fordirect mounting to the Kim speed mount. Wire entries are sealed bya silicone grommet. Integral latches (2) are die-cast aluminum withstainless steel springs and stainless steel hangers for the refractor.

Refractor: Standard refractor is one-piece injection moldedpolycarbonate .125" minimum wall thickness. Optional refractor isone-piece injection molded UV stabilized acrylic, .125" minimum wallthickness. Refractor attaches to electrical housing with (2) no-toolquick release latches, with one latch captive as a hinge. Perimeter isfully sealed with a one-piece extruded silicone gasket, with the endsfused together to form a continuous piece, sealing the refractor to theelectrical housing, and providing an IP66 fixture rating.

Upper Reflector and Socket: One-piece hydroformed aluminumwith a vacuum metalized reflective finish and protective coating.Reflector has keyhole slots for no-tool removal from the electricalhousing for ballast access. HID socket is 4KV pulse rated mediumbase. Optional G-12 base socket available for 150PMH lamp mode.

Reflector Modules: Specular aluminum panels. Reflectors areattached to the upper reflector, and configured for up-light, or restricted up-light depending on the specified fixture.Reflector modules are included in all models except the PGL51.

Electrical Components: Magnetic HID ballasts are high powerfactor, -20°F starting, mounted directly to the electrical housing.

Finish: Fade and abrasion resistant, electrostatically applied,thermally cured finish on fixture electrical housing and optional PB2and TB2 is (WH) white triglycidal isocyanurate (TGIC) polyesterpowdercoat paint. Consult factory for custom color (Include RAL#).

Listed To: UL 1598 Standard for Luminaires and CSA C22.2#250.0Luminaires.

CAUTION: Fixtures must be grounded in accordance with national,state and/or local electrical codes. Failure to do so may result inserious personal injury.

Page 11: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

100HPS 120 1.15 2.20 1.30 2.20ED-17 Clear 100 S-54 24K+ 9500 208 0.67 1.25 0.75 1.25Medium Base 240 0.58 1.10 0.65 1.10

277 0.50 0.85 0.60 0.85347 0.39 0.70 0.45 0.70480 0.29 0.55 0.35 0.55

150HPS 120 1.65 2.80 2.00 2.80

ED-17 Clear 150 S-55 24K+ 16000 208 0.95 1.60 1.15 1.60

Medium Base 240 0.83 1.40 1.00 1.40277 0.72 1.25 0.85 1.25347 0.56 0.92 0.52 0.92480 0.42 0.70 0.50 0.70

100PMH 120 1.15 2.30 1.20 2.30ED-17 Clear 100 M-90 16K+ 9500 208 0.66 1.40 0.80 1.40Medium Base 240 0.58 1.15 0.65 1.15

277 0.50 1.00 0.60 1.00347 0.40 1.00 0.40 1.00480 0.30 0.55 0.30 0.55

150PMH 120 1.60 3.65 1.75 3.65ED-17 Clear

150 M-10215K+

14000208 1.00 2.10 1.30 2.10

Medium Base 240 0.80 1.80 0.85 1.80277 0.70 1.58 0.77 1.58

T6 Clear 12K 347 0.55 1.25 0.65 1.25G12 Base 480 0.42 0.81 0.45 0.81

175PMH 120 1.80 1.80 0.95 1.80

ED-17 Clear 175 M-137 15K+ 17500 208 1.05 1.05 0.55 1.05

Medium Base 240 0.90 0.90 0.45 0.90277 0.80 0.80 0.40 0.80347 0.63 0.60 0.32 0.63480 0.45 0.62 0.15 0.62

200PMH 120 2.00 2.00 0.75 2.00

ED-17 Clear 200 M-136 12K+ 21000 208 1.20 1.20 0.40 1.20

Medium Base 240 1.00 1.00 0.35 1.00277 0.85 0.85 0.30 0.85347 0.70 0.65 0.25 0.70480 0.54 0.43 0.19 0.54

Lamp and Electrical Guide

KIM LIGHTING 9

Lamp

HIGH PRESSURE SODIUM

Lam

pW

atts

AN

SI

Bal

last

Typ

e

Lif

e(H

ou

rs)

Init

ial

Lu

men

s1

Volt

age

Ope

ratin

gA

mps

.

Op

enC

ircu

it

Sta

rtin

gA

mp

s.

Max

.A

mp

s.

PULSE START METAL HALIDE

1 Consult lamp manufacturer’s data for exact lumen and life data.

Page 12: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

Fixture Fixture Maintained HorizontalMounting Spacing Footcandles on Deck

Bay Height Maintained UniformityWidth H S A B C D E F Avg. fc Avg./Min. Max./Min.

55'

8'20' 13.5 11 6.2 5.9 2.5 2.5 5.93 2.37 5.4

30' 10.6 6.3 3.8 3.8 1.6 1.8 4.05 2.53 6.63

9'20' 11.9 10.2 6 5.9 3.5 3.5 6.04 1.73 3.4

30' 9.1 5.3 3.9 3.8 2.3 2.4 4.05 1.76 3.96

60'

8'20' 13.5 10.9 5.3 5.6 1.7 1.7 5.41 3.18 7.94

30' 10.6 6.3 3.8 3.8 1.2 1.4 3.89 3.24 8.83

9'20' 11.8 10.2 5.6 5.4 2.5 2.5 5.44 2.18 4.72

30' 9.1 5.2 3.8 3.7 1.7 1.8 3.76 2.21 5.35

55'

8'20' 16.6 14.4 9 7.8 3.3 3.3 7.77 2.35 5.03

30' 12.2 9 5.4 5.6 2.2 2.3 5.35 2.43 5.55

9'20' 15 13.5 8.5 7.9 4.2 4.3 7.85 1.87 3.57

30' 10.4 7.6 6 5.3 2.8 2.9 5.25 1.88 3.71

60'

8'20' 16.6 14.3 8 7.2 2.4 2.4 7.11 2.96 6.92

30' 12.2 8.9 5.3 5.5 1.7 1.8 5.1 3 7.18

9'20' 14.9 13.4 8 7.3 3.2 3.2 7.17 2.24 4.66

30' 10.4 7.6 5.9 5.1 2.2 2.3 4.95 2.25 4.73

10 KIM LIGHTING

PGL51 - Single Row SystemMaintainedIllumination for aSystem of Fixtures

6L"(171.5 mm)

MOUNTING HEIGHT - H

NOT TO SCALEF

F

D

D

A

E

E

C

C

B

F

F

D

D

A

PLAN VIEW

SBay

Width

NOTE: All values are maintainedillumination which include 40% ceilingreflection, contribution from adjoiningbays, and estimated lamp andluminaire depreciation betweenmaintenance cycles. Surface reflectionsfrom structural beams were notconsidered (flat ceiling presumed).Normal lamp output tolerances, jobsiteelectrical variations, maintenanceschedules and surface reflectioncharacteristics can affect accuracy.

6L"(171.5 mm)

MOUNTING HEIGHT - H

NOT TO SCALE

150 Watt PMHPGL51 onlyED-17 clearmedium base14,000 initial lumensKim Test No. KL00978Light Loss Factor: 0.72

150 Watt HPSPGL51 onlyED-17 clearmedium base16,000 initial lumensKim Test No. KL00919Light Loss Factor: 0.81

For Optional Acrylic Refractor, Multiply by 1.065

Standard Polycarbonate Refractor

Page 13: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

KIM LIGHTING 11

Standard Polycarbonate RefractorPGL51 - Double Row System

MaintainedIllumination for aSystem of Fixtures

6L"(171.5 mm)

MOUNTING HEIGHT - H

NOT TO SCALE

NOTE: All values are maintainedillumination which include 40% ceilingreflection, contribution from adjoiningbays, and estimated lamp andluminaire depreciation betweenmaintenance cycles. Surface reflectionsfrom structural beams were notconsidered (flat ceiling presumed).Normal lamp output tolerances, jobsiteelectrical variations, maintenanceschedules and surface reflectioncharacteristics can affect accuracy.

6L"(171.5 mm)

MOUNTING HEIGHT - H

NOT TO SCALE

Fixture Fixture Maintained HorizontalMounting Spacing Footcandles on Deck

Bay Height Maintained UniformityWidth H L S A B C D E F Avg. fc Avg./Min. Max./Min.

55'

8' 27.5'20' 16.1 13.6 12.4 11.9 12.3 11.9 13.33 1.12 1.35

30' 12.5 7.9 7.6 7.7 7.6 7.7 8.99 1.18 1.64

9' 27.5'20' 15.4 13.8 12.2 11.8 12.1 11.8 13.09 1.11 1.31

30' 11.6 7.6 7.9 7.6 7.8 7.5 8.69 1.16 1.55

60'

8' 30'20' 15.2 12.7 10.5 11.2 10.5 11.2 12.33 1.17 1.45

30' 11.8 7.4 7.2 7.4 7.2 7.4 8.53 1.18 1.64

9' 30'20' 14.3 12.7 11.2 10.8 11.2 10.8 12.07 1.12 1.32

30' 10.9 6.9 6.9 6.9 6.9 6.9 7.97 1.16 1.58

55'

8' 27.5'20' 20 17.8 18.1 15.7 18.1 15.6 17.58 1.13 1.28

30' 14.5 11.2 10.9 11.1 10.8 11.1 11.97 1.11 1.34

9' 27.5'20' 19.4 17.8 17 16 17 16 17.35 1.08 1.21

30' 13.4 10.4 12 10.5 12 10.5 11.56 1.11 1.29

60'

8' 30'20' 19 16.7 15.9 14.4 15.9 14.4 16.23 1.13 1.32

30' 13.9 10.5 9.5 10.5 9.5 10.5 11.21 1.18 1.46

9' 30'20' 18.6 16.7 16.1 14.6 16.1 14.5 16.23 1.12 1.28

30' 12.6 9.8 10.7 9.8 10.7 9.8 10.73 1.09 1.29

150 Watt PMHPGL51 onlyED-17 clearmedium base14,000 initial lumensKim Test No. KL00978Light Loss Factor: 0.72

150 Watt HPSPGL51 onlyED-17 clearmedium base16,000 initial lumensKim Test No. 00919Light Loss Factor: 0.81

For Optional Acrylic Refractor, Multiply by 1.065

Page 14: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

12 KIM LIGHTING

PGL52 - Single Row SystemMaintainedIllumination for aSystem of Fixtures

Fixture Fixture Maintained HorizontalMounting Spacing Footcandles on Deck

Bay Height Maintained UniformityWidth H S A B C D E F Avg. fc Avg./Min. Max./Min.

55'

8'20' 15.1 9.6 7.3 6.3 1.8 1.5 5.95 3.97 10.07

30' 13.2 5.4 5.7 3.9 1.2 1 4.35 4.35 13.2

9'20' 12.9 8.7 6.8 6.7 2.7 2.2 5.94 2.7 5.86

30' 10.9 5.9 5.7 3.5 2 1.4 4.18 2.99 7.79

60'

8'20' 15.1 9.6 6.5 5.1 1.2 1 5.31 5.31 15.1

30' 13.2 5.3 5.7 3.8 0.9 0.7 4.19 5.99 18.86

9'20' 12.8 8.7 6 6.2 1.8 1.6 5.43 3.39 8

30' 10.8 5.8 5.7 3.5 1.4 1 3.97 3.97 10.8

55'

8'20' 18.2 12.5 11.4 7.6 2.4 2.2 7.71 3.5 8.27

30' 15.9 7.1 6.3 5 1.8 1.3 5.35 4.12 12.23

9'20' 15.7 11.5 11.8 8.1 3.3 3.1 7.86 2.54 5.06

30' 13 7.4 7.6 4.9 2.5 1.8 5.36 2.98 7.22

60'

8'20' 18.1 12.5 9.1 6.4 1.7 1.6 6.82 4.26 11.31

30' 15.8 7.1 6.3 5 1.4 1 5.21 5.21 15.8

9'20' 15.6 11.4 10 7.3 2.4 2.2 7.03 3.2 7.09

30' 13 7.3 7.5 4.8 1.9 1.4 5.13 3.66 9.29

6L"(171.5 mm)

MOUNTING HEIGHT - H

NOT TO SCALEF

F

D

D

A

E

E

C

C

B

F

F

D

D

A

PLAN VIEW

SBay

Width

NOTE: All values are maintainedillumination which include 40% ceilingreflection, contribution from adjoiningbays, and estimated lamp andluminaire depreciation betweenmaintenance cycles. Surface reflectionsfrom structural beams were notconsidered (flat ceiling presumed).Normal lamp output tolerances, jobsiteelectrical variations, maintenanceschedules and surface reflectioncharacteristics can affect accuracy.

6L"(171.5 mm)

MOUNTING HEIGHT - H

NOT TO SCALE

150 Watt PMHPGL52 onlyED-17 clearmedium base14,000 initial lumensKim Test No. KL00980Light Loss Factor: 0.72

150 Watt HPSPGL52 onlyED-17 clearmedium base16,000 initial lumensKim Test No. KL00925Light Loss Factor: 0.81

Standard Polycarbonate Refractor

For Optional Acrylic Refractor, Multiply by 1.065

Page 15: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

KIM LIGHTING 13

PGL52 - Double Row SystemMaintainedIllumination for aSystem of Fixtures

6L"(171.5 mm)

MOUNTING HEIGHT - H

NOT TO SCALE

NOTE: All values are maintainedillumination which include 40% ceilingreflection, contribution from adjoiningbays, and estimated lamp andluminaire depreciation betweenmaintenance cycles. Surface reflectionsfrom structural beams were notconsidered (flat ceiling presumed).Normal lamp output tolerances, jobsiteelectrical variations, maintenanceschedules and surface reflectioncharacteristics can affect accuracy.

6L"(171.5 mm)

MOUNTING HEIGHT - H

NOT TO SCALE

Fixture Fixture Maintained HorizontalMounting Spacing Footcandles on Deck

Bay Height Maintained UniformityWidth H L S A B C D E F Avg. fc Avg./Min. Max./Min.

55'

8' 27.5'20' 16.7 11.4 14.7 12.6 14.7 12.6 13.95 1.22 1.47

30' 14.2 6.6 11.5 7.7 11.5 7.7 10.05 1.52 2.15

9' 27.5'20' 15.2 11.5 13.7 13.5 13.7 13.5 13.73 1.19 1.32

30' 12.2 7.8 11.5 7.1 11.5 7.1 9.43 1.35 1.72

60'

8' 30'20' 16.1 10.8 13 10.1 12.9 10.1 12.36 1.22 1.59

30' 13.8 6.2 10.2 5.9 10.2 5.9 8.91 1.51 2.34

9' 30'20' 14.4 10.5 12.1 12.5 12.6 12.5 12.65 1.2 1.37

30' 11.8 7.1 10.8 6.7 10.8 6.7 8.93 1.33 1.76

55'

8' 27.5'20' 20.4 15 22.8 15.3 22.8 15.2 18.09 1.21 1.52

30' 17.2 8.9 12.7 10.1 12.7 10.1 12.35 1.39 1.93

9' 27.5'20' 18.9 14.9 23.6 16.2 23.6 16.2 18.23 1.22 1.58

30' 14.9 9.9 15.2 9.8 15.2 9.8 12.25 1.25 1.55

60'

8' 30'20' 19.7 14.2 18.3 12.8 18.2 12.8 15.91 1.24 1.54

30' 16.8 8.3 11.1 8.3 11.1 8.3 11.13 1.34 2.02

9' 30'20' 17.9 13.8 20 14.6 19.9 14.6 16.44 1.19 1.45

30' 14.3 9.1 13.3 9 13.3 9 11.29 1.25 1.59

150 Watt PMHPGL52 onlyED-17 clearmedium base14,000 initial lumensKim Test No. KL00980Light Loss Factor: 0.72

150 Watt HPSPGL52 onlyED-17 clearmedium base16,000 initial lumensKim Test No. KL00925Light Loss Factor: 0.81

Standard Polycarbonate Refractor

For Optional Acrylic Refractor, Multiply by 1.065

Page 16: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

14 KIM LIGHTING

PGL53 - Single Row SystemMaintainedIllumination for aSystem of Fixtures

Fixture Fixture Maintained HorizontalMounting Spacing Footcandles on Deck

Bay Height Maintained UniformityWidth H S A B C D E F Avg. fc Avg./Min. Max./Min.

55'

8'20' 9.6 9.3 8 7 2.7 2.8 5.94 2.2 3.56

30' 9 2.6 3.7 5.8 1.6 2.2 4.21 2.63 5.63

9'20' 8.2 8.5 7.7 6.9 3.8 4 6.1 1.61 2.24

30' 7.3 3.3 4.4 5.4 2.4 3 4.34 1.81 3.04

60'

8'20' 9.5 9.2 6.8 6.3 1.9 1.9 5.23 2.75 5

30' 9 2.6 3.6 5.7 1.2 1.6 3.96 3.3 7.5

9'20' 8.2 8.4 7.1 6.3 2.7 2.8 5.39 2 3.11

30' 7.3 3.2 4.3 5.4 1.8 2.2 4.03 2.24 4.06

55'

8'20' 10.8 11.3 11 9.1 3.5 3.6 7.51 2.15 3.23

30' 9.8 3.5 4.6 7.6 2.2 2.7 5.19 2.36 4.45

9'20' 9.4 10.7 11.4 9.1 4.5 4.8 7.79 1.77 2.59

30' 8 4 5.8 7.2 2.9 3.5 5.35 1.84 2.76

60'

8'20' 10.7 11.3 9.4 8.3 2.6 2.6 6.69 2.57 4.35

30' 9.7 3.4 4.5 7.5 1.7 2 4.88 2.87 5.71

9'20' 9.3 10.7 10 8.2 3.4 3.5 6.86 2.02 3.15

30' 8 3.9 5.7 7.1 2.3 2.7 5.01 2.18 3.48

6L"(171.5 mm)

MOUNTING HEIGHT - H

NOT TO SCALEF

F

D

D

A

E

E

C

C

B

F

F

D

D

A

PLAN VIEW

SBay

Width

NOTE: All values are maintainedillumination which include 40% ceilingreflection, contribution from adjoiningbays, and estimated lamp andluminaire depreciation betweenmaintenance cycles. Surface reflectionsfrom structural beams were notconsidered (flat ceiling presumed).Normal lamp output tolerances, jobsiteelectrical variations, maintenanceschedules and surface reflectioncharacteristics can affect accuracy.

6L"(171.5 mm)

MOUNTING HEIGHT - H

NOT TO SCALE

150 Watt PMHPGL53 onlyED-17 clearmedium base14,000 initial lumensKim Test No. KL00982Light Loss Factor: 0.72

150 Watt HPSPGL53 onlyED-17 clearmedium base16,000 initial lumensKim Test No. KL00927Light Loss Factor: 0.81

Standard Polycarbonate Refractor

For Optional Acrylic Refractor, Multiply by 1.065

Page 17: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

KIM LIGHTING 15

PGL54 - Double Row SystemMaintainedIllumination for aSystem of Fixtures

6L"(171.5 mm)

MOUNTING HEIGHT - H

NOT TO SCALE

NOTE: All values are maintainedillumination which include 40% ceilingreflection, contribution from adjoiningbays, and estimated lamp andluminaire depreciation betweenmaintenance cycles. Surface reflectionsfrom structural beams were notconsidered (flat ceiling presumed).Normal lamp output tolerances, jobsiteelectrical variations, maintenanceschedules and surface reflectioncharacteristics can affect accuracy.

6L"(171.5 mm)

MOUNTING HEIGHT - H

NOT TO SCALE

Fixture Fixture Maintained HorizontalMounting Spacing Footcandles on Deck

Bay Height Maintained UniformityWidth H L S A B C D E F Avg. fc Avg./Min. Max./Min.

55'

8'' 27.5'20' 16.2 14.8 12.1 9.2 12 9.2 12.38 1.35 1.76

30' 10.5 10.7 8.6 4.9 8.5 4.9 7.89 1.61 2.18

9' 27.5'20' 15 12.8 12.5 11.2 12.5 11.2 12.69 1.13 1.34

30' 9.5 10.2 9.9 6.2 9.8 6.2 8.35 1.35 1.66

60'

8' 30'20' 15.8 14.5 9.3 7.2 9.2 7.2 10.87 1.51 2.19

30' 10.3 10.5 6.9 3.7 6.9 3.7 7.01 1.89 2.84

9' 30'20' 14.5 12.3 10.7 9.2 10.7 9.2 11.33 1.23 1.58

30' 9.3 9.9 8.1 4.9 8.1 4.9 7.38 1.51 2.02

55'

8' 27.5'20' 19.6 21.6 16.1 11.1 16 11.1 15.75 1.42 1.95

30' 11.8 14.3 10.7 6.4 10.7 6.4 9.75 1.52 2.23

9' 27.5'20' 18.7 18.2 17.7 13.7 17.6 13.7 16.42 1.2 1.37

30' 10.7 13.5 13.1 7.5 13.1 7.5 10.27 1.37 1.8

60'

8' 30'20' 19.1 21.1 12.1 8.9 12.1 8.9 13.89 1.56 2.37

30' 11.6 14 8.5 5.1 8.5 5 8.67 1.73 2.8

9' 30'20' 18 17.5 14.3 11.3 14.3 11.3 14.51 1.28 1.59

30' 10.4 13.1 10.5 6.2 10.5 6.2 9.1 1.47 2.11

150 Watt PMHPGL54 onlyED-17 clearmedium base14,000 initial lumensKim Test No. KL00982Light Loss Factor: 0.72

150 Watt HPSPGL54 onlyED-17 clearmedium base16,000 initial lumensKim Test No. KL00927Light Loss Factor: 0.81

Standard Polycarbonate Refractor

For Optional Acrylic Refractor, Multiply by 1.065

Page 18: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

16 KIM LIGHTING

PGL56 - Single Row SystemMaintainedIllumination for aSystem of Fixtures

Fixture Fixture Maintained HorizontalMounting Spacing Footcandles on Deck

Bay Height Maintained UniformityWidth H S A B C D E F Avg. fc Avg./Min. Max./Min.

55'

8'20' 14.2 9.9 7.3 5.7 2.1 2 5.86 2.93 7.1

30' 12 5 4.8 3.4 1.4 1.4 4.04 2.89 8.57

9'20' 12.1 9.4 7.2 6.3 3.1 2.8 6.04 2.16 4.32

30' 10.1 5.1 5 3.6 2.1 1.9 4.1 2.16 5.32

60'

8'20' 14.1 9.9 6.2 4.9 1.4 1.4 5.23 3.74 10.07

30' 12 5 4.8 3.3 1 1 3.85 3.85 12

9'20' 12.1 9.3 6.4 5.6 2.1 2 5.39 2.7 6.05

30' 10 5 4.9 3.6 1.6 1.4 3.87 2.76 7.14

55'

8'20' 16.9 12.7 10.7 7.1 2.8 2.7 7.51 2.78 6.26

30' 14 6.7 6 4.7 2 1.8 5.1 2.83 7.78

9'20' 14.7 11.8 11.1 7.9 3.7 3.7 7.79 2.16 4.08

30' 11.6 6.6 7.2 4.9 2.6 2.4 5.23 2.18 4.83

60'

8'20' 16.8 12.6 8.7 6.3 2 2 6.71 3.36 8.4

30' 13.9 6.7 5.9 4.6 1.5 1.4 4.89 3.49 9.93

9'20' 14.6 11.7 9.5 6.9 2.7 2.7 6.92 2.56 5.44

30' 11.6 6.6 7.1 4.8 2 1.9 4.97 2.62 6.11

6L"(171.5 mm)

MOUNTING HEIGHT - H

NOT TO SCALEF

F

D

D

A

E

E

C

C

B

F

F

D

D

A

PLAN VIEW

SBay

Width

NOTE: All values are maintainedillumination which include 40% ceilingreflection, contribution from adjoiningbays, and estimated lamp andluminaire depreciation betweenmaintenance cycles. Surface reflectionsfrom structural beams were notconsidered (flat ceiling presumed).Normal lamp output tolerances, jobsiteelectrical variations, maintenanceschedules and surface reflectioncharacteristics can affect accuracy.

6L"(171.5 mm)

MOUNTING HEIGHT - H

NOT TO SCALE

150 Watt PMHPGL56 onlyED-17 clearmedium base14,000 initial lumensKim Test No. KL00985Light Loss Factor: 0.72

150 Watt HPSPGL56 onlyED-17 clearmedium base16,000 initial lumensKim Test No. KL00929Light Loss Factor: 0.81

Standard Polycarbonate Refractor

For Optional Acrylic Refractor, Multiply by 1.065

Page 19: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

KIM LIGHTING 17

Page 20: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

18 KIM LIGHTING

Related Products

Top Deck LightingAn open top deck is essentiallya parking lot where polemounted luminaires offer thegreatest efficiency. Becausethey are totally exposed to theelements, these fixtures must beof the highest quality. Of equalimportance, top deck luminairesmust complement the buildingarchitecture since their relationshipis openly visible to aestheticscrutiny. Kim Lighting offers acomprehensive line of polemounted luminaires combiningrugged construction, highperformance and architecturalcompatibility. They are beingused for top deck lightingthroughout the world withunqualified success.Refer to the following Kimproduct lines and their respectivecatalogs:AR/SAR The Archetype®

AC Die-Cast CurvilinearAE Era® AcornBE Era® BellCC/CCS Curvilinear CutoffET/SET The Entablature®

LEB/LET Era® LanternMX Matrix™

RA Era®

OTS Outdoor Tube SystemSTS/STL/STX Structural™

VL Vertical Lamp LuminairesWP9 WARP9®

Stairways and PedestrianBridgesThe I.E.S. recommends amaintained average of 10 to 20footcandles on stairways. Thisrequires a luminaire far moreefficient than the typical steplight. The Kim Low LevelFloodlight is a perfect solutionfor stairways and pedestrianbridges because of itssophisticated optics. An entireflight of stairs can normally beilluminated with a single LLFbecause the light is throwndownward at the same angleas the stairway. See Kim LLFcatalog. The Kim Wall Formsprovide an aesthetic accent ina robust design. See Kim WFcatalog.

Page 21: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

Kim PB2BalancedPendantJ-Box

PGL53

8J"(209.6 mm)

Free SwingingFree SwingingL"L" Conduit Pendant Conduit Pendant(by others)(by others)

Free SwingingL" Conduit Pendant(by others)

14E"(377.8 mm)LEXAN® SLX

16J"(412.8 mm)ACRYLIC

4J"(108.0 mm)

KIM LIGHTING 19

Other Applications

Double-T Structural SystemsThe most difficult obstacle in parkinggarage lighting is the double-Tstructure in which the entire ceilingacts as a light-absorbing baffle. Thisprevents broad lighting of theceiling and beams for visualsecurity. The PGL53 is the bestsolution because its rectangularlight pattern is least affected by theclosely spaced beams. For optimumperformance, the PGL53 fixtureshould be suspended by apendant using the optional PB2balanced pendant junction boxand bird shroud. The bottom of thefixture should be even with thebottom of the beams, or even lowerif heights permit.

Adding or Relocating FixturesOlder parking garages are oftenpoorly illuminated because thecriteria for lighting was not wellestablished when they wereconstructed, and true parkingluminaires did not exist. Theseolder garages can be brought upto today’s lighting standards byreplacing the existing fixtures withKim’s PGL5 luminaires, or addingthese new luminaires to the existingsystem. Surface mounted conduitruns are normally used for fixtureadditions using one of the twomethods at left.

Conversion from Fluorescentto HIDParking garages with fluorescentlighting lack the efficiency andlong term performance of HIDsystems. Fluorescent lighting isoften bare lamp, which meansthey have no optical control, andcollect dirt and dust very rapidly.Also, fluorescent lamps aretemperature sensitive, withoutput reduced as the ambienttemperature decreases orincreases from the 77°F optimum.Because fluorescent systems areusually double-row configurations,the change to HID is relativelyeasy because the electricaldistribution is in the correctlocation for PGL54s.

VERTICAL SECTIONTHROUGH DOUBLE-T PLAN VIEW –– TYPICAL BAY

Fixture Mounted to Junction BoxA standard 4" junction box is fastened to theceiling and fed with surface mountedconduit. A PGL5 fixture is then mounted tothe junction box using the standard Kimspeed mount as illustrated on page 5. This isthe easiest method of adding fixturesbecause all standard components are used.

PGL5 Fixture used as a Junction BoxThis method is more difficult to install, but offers theadvantage of reduced depth where floor-to-ceilingdistance is minimal. The PGL5 fixtures must be orderedwith K" or L" N.P.T. conduit taps (Consult Factory). The refractor and upper reflector must be removed toallow fixture mounting to the ceiling, and field wiring.Fixtures are listed for 90°C through-wiring.

10K"(266.7 mm)

APPROX.12J"

(311.2 mm)

PLAN VIEW –– TYPICAL DOUBLEROW FLUORESCENT SYSTEM

TYPICAL 8' FLUORESCENTFIXTURE, DOUBLE ROW,FIXTURES BETWEENEVERY BEAM.

PLAN VIEW –– FLUORESCENTSYSTEM CONVERTED TO PGL54s

PGL54, DOUBLE ROW,FIXTURES BETWEEN EVERY OTHER BEAM.

Dimensions with standard Lexan® SLX

refractor

Page 22: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

20 KIM LIGHTING

Other Kim Parking Garage Luminaires

The PGL Omni-System was the second generation of Kimparking garage luminaires, but employed a totally differentoptical system and look than the PGL4. Due to the uniquenessand success of this luminaire, Kim is also retaining this productfor legacy requirements.

The PGL4 is an advanced version of the original Kim PGLintroduced in 1988. Because there are hundreds of thousands ofthese luminaires throughout the World, Kim is retaining thismodel for projects where replacements or additions are required,and keeping the original fixture configuration is desired.

Page 23: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

KIM LIGHTING 21

Application Engineering Services

Applications AssistanceKim Lighting utilizes the latest computer technology and soft-ware to provide specifiers with reliable evaluations of lightingsystem performance. We can analyze a proposed luminairelayout or provide recommendations based on performancecriteria.Electronic copies of plans can be sent directly to [email protected]. Hard copies can be sent by faxat 864-678-1743, or they can be mailed to Applications Dept, 701 Millennium Blvd, Greenville, SC 29607.

Photometric FilesKim Lighting .ies format photometric files are available foruse in lighting calculation software. The complete IES FileLibrary is on the internet at www.kimlighting.com.

PGL7 LED, the newest innovation in parking structure luminaires,offers multi-distributions that allow light to be directed where it isneeded. The future of parking structure and low mounting heightlighting solutions is here. Type I and Type V, 5100K are DLCapproved.

Page 24: PGL5 - hubbellcdn · 2017-01-13 · 30" 60" A B C PGL5 Today’s parking garage illumination guidelines involve both horizontal and vertical footcandles up to 60" above the floor

How may we serve you better? Let us know by visiting our web site at:

www.kimlighting.com

Your input is valuable to us.

Because of a continuing product improvementprogram, Kim Lighting reserves the right tochange specifications without notice.

PGL5U n i v e r s a l P a r k i n g G a r a g e L u m i n a i r e