pg.70-71(hid -future f)x (page 1) - frontier lighting · rab lighting, inc. š 170 ludlow aveš...
TRANSCRIPT
FF150
JOB NAME:
DATE:
TYPE:
DESCRIPTIONCompact, tough and good looking cast aluminum housing with hinged framed glass lens.Integra Hood glare shield and stainless steel clip. 35 to 150 watt HPS Metal Halide PulseStart. 50 & 70 watt with 120v reactor ballast or 100W with 277V NPF ballast. Lampincluded.
SPECIFICATIONSFinish:Chip and fade resistant polyester powdercoating
Housing:Precision die cast aluminum, 1/2" NPSthreaded arm with locking swivel fits allstandard mounting boxes
Lens Gasket:High temperature tubular silicone set in diecast retaining groove remains in placeduring relamping
Lens:Thermal tempered shock resistant glassReflector:Anodized semi-specular aluminum
Socket:Glazed porcelain 4kv pulse rated with nickelplated screw shell and spring contacts
Sockets:Porcelain with all copper current carryingcomponents
UL Listing:Suitable for wet locations. Suitable formounting within 4' of the ground
EPA:0.43Patents:Pat. D420,458Color:BronzeWeight:8.42
DIMENSIONS
PHOTOMETRIC
ORDERING INFORMATIONHigh Pressure Sodium Total
WattsLamp Type
Lamp Base Ballast
Starting Amps/ Operating Amps120V 208V 240V 277V
Input Watts
LAMP ANSI
Initial Lumens
Lamp HoursLamp supplied with fixture
150 ED17 Medium R-NPF 120V 4.5/3.2 170 S55 16000 24000
Factory Installed OptionsAdd suffix to Catalog Number
Swivel Photocontrol (/PCS)Single fusing for 120 and 277 volt (/F)
Double fusing for 208 and 240 volt. (/FF)Button Photocontrol (/PC)
RAB Lighting, Inc. • 170 Ludlow Ave• Northvale, NJ 07647 • Tel: 888 RAB-1000 • Fax: 888 RAB-1232 • www.rabweb.com© 2007
Note: Specifications may change without notice
FUTURE FLOOD INSTALLATION INSTRUCTIONS
IMPORTANTREAD CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
WARNING: Make certain power is OFF before installing or maintaining fixture.
Thank you for buying RAB lighting fixtures. Our aim is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000, or email: [email protected]
LOCATIONSecure the Future Flood to any 1/2” NPS hole in a metal plate coverplate, junction box or landscape post. Plug all unused holes and seal threads with silicone.
The swivel arm on the Future Flood allows 150º of vertical aiming adjustment.
Do not aim fixture to any object closer than 18 inches.
LAMP INSTALLATIONCAUTION: Prior to installing, check that the lamp is the correct ANSI type and wattage. Observe lamp manufacturer’s recommendations on lamp operation, ballast type and burning positions.
Disconnect power. Make sure fixture and lamp are cool enough to touch.
Remove screw from the door clip on the top of the fixture. Open fixture, swing door down on hinges.
Fully insert lamp into socket.
Before closing door, make sure frame gasket is properly seated all around the fixture.
Close door. Replace screw on door clip, if desired.
1.
2.
3.
1.
2.
3.
4.
5.
WIRINGDo not use any supply voltage other than those specified below: FF35-FF150 HPS 120V only FFH50-70 MH 120V only FFH100/277V 277V only FF42QT 120V thru 277V*
*No internal wiring changes needed for various voltages as the ballast is quad tap electronic.
Connect the black fixture lead to the (+) LINE supply lead.
Connect the white fixture lead to the (-) COMMON supply lead.
Connect the bare copper Ground wire from fixture to supply ground.
1.
2.
3.
CLEANING & MAINTENANCE CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.
Clean glass lens with non-abrasive glass cleaning solution.
As lamps age, light output diminishes. Mass relamping at regular intervals ensures full light output at the highest efficiency.
1.
2.
FUTURE FLOOD INSTALLATION INSTRUCTIONS
TROUBLESHOOTING Is the proper lamp is installed? Check the wattage and ANSI code on the fixture label against markings on the lamp. Refer to Replacement Lamp table above for verification.
Make sure the lamp is not defective. Try a lamp known to be in operating condition.
Check that the line voltage at fixture is correct. Refer to wiring directions.
Is there voltage at the lamp socket? If there is no voltage, check all connections.
Is the fixture is grounded properly?
Is the photocell is functioning properly (if used)?
1.
2.
3.
4.
5.
6.
ACCESSORIES AND REPLACEMENT PARTSChrome Wire Guard: GDFF Door and Frame with Glass: LFF (bronze) LFFW (white)Swivel Arm: FFLARMA (bronze) FFLARMW (white)Factory Installed Photocell: “/PC” (120V) “/PC2” (277V) “/PCS” (Swivel 120V)
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
FF-IN-0407
REPLACEMENT LAMPS AND BALLASTS Lamp ANSI Ballast Wattage Catalog# Code Catalog#High Pressure Sodium35 LHPS35 S76 BHPSN3550 LHPS50 S68 BHPSN5070 LHPS70 S62 BHPSN70 100 LHPS100 S54 BHPSN100 150 LHPS150 S55 BHPSN150Metal Halide50 LMH50 M110 BMHN5070 LMH70 M98 BMHN70 100 LMH100 M90 BMHN100/277Compact Fluorescent Base Type42 LCFL42 GX24q-4 BCLF42
GUARD INSTALLATION
Slide top and bottom ends of one side of guard into notches in the door frame.
Squeeze guard and slide the other ends of the guard into notches on the opposite side of the frame.
1.
2.
Slide end of guard into notch
Factory Installed OptionsAdd suffix to catalog number
Accessories for Field Installation:
4 3 2 1 0 1 2 3 4
01
2
3
4
5
5 fc2 fc
1 fc
0.2 fc
4 3 2 1 0 1 2 3 4
p g
Isofootcandle Diagram
5
4
3
2
1
0
13fc 50fc
105fc
4fc
Multiples of Distance to Sign/Wall(2' multiples)
Compact, tough and good lookingcast aluminum housing with hingedframed glass lens. Integra Hoodglare shield and stainless steel clip.35 to 150 watt HPS Metal HalidePulse Start. 50 & 70 watt with 120vreactor ballast or 100w with 277vNPF ballast. Lamp included.
/PC/PCS
/PC/PCS
/PC/PCS
FF HPS & MH
LampType
Lamp Base Ballast Bronze White White
Starting Amps / Operating Amps
ED17ED17ED17
MedMedMed
2 / 1.62.5 / 2.1Available in 277 volt only .7 / .5
LMH50LMH70LMH100
Bronze120V 208V 240V 277V
1.4 / 0.91.8 / 1.22.1 / 1.63.1 / 2.14.5 / 3.2
355070
100150
ED17ED17ED17ED17ED17
FF35FF50FF70FF100FF150
FF35WFF50WFF70WFF100WFF150W
FF42QT FF42QTW
Finish: Architectural BronzeWhite
Finish: Architectural BronzeWhite
UL Listing:Suitable for wet locations. Suitable formounting within 4’ of the ground.
Housing:Precision die cast aluminum, 1/2” NPSthreaded arm with locking swivel fits allstandard mounting boxes.
Reflector:Anodized semi-specular aluminum
Lens:Thermal tempered shock resistant glass
Lens Gasket:High temperature tubular silicone set in diecast retaining groove remains in place during relamping.
Socket:Glazed porcelain 4kv pulse rated with nickel plated screw shell and spring contacts.
GDFF
Finish: Chrome plated steel
Sign & Wall Lighting 150w HPS @ 6’ from wall - 30º above horizontal
Multiples of Mounting Height
Order fixture+ order GDFF guard
Order fixture+ order GDFF guard
BMHN50BMHN70BMHN100/277*
LHPS35LHPS50LHPS70LHPS100LHPS150
BHPSN35BHPSN50BHPSN70BHPSN100BHPSN150
GX24q-442 .4 .3 .2 .2
79
8”20.3 cm
The popular choice for reliable security.
78
MedMedMedMedMed
R-NPF 120VR-NPF 120VR-NPF 120VR-NPF 120VR-NPF 120V
Input Watts
InitialLumens
LampHours
24,00024,00024,00024,00024,000
7294
129
46
3,4005,6009,000
3,200
10,00015,00015,000
12,000
2,2504,0006,4009,500
16,000
466286
115170
M110M98M90
S76S68S62S54S55
150w HPS @ 10’ Mounting HeightAimed 30º below horizontal
6 3/4”17.1cm
*100 watt Metal Halide is 277 volt only
DimensionsSpecifications
FF GuardHeavy duty chrome plated steelwire guard prevents damage andvandalism. Easily field installable.Also fits QF500F Quartz flood.
White light in a compact package.Compact Fluorescent 42 watt withquad tap electronic ballast. Lamp included.
Button PhotocontrolSwivel Photocontrol
9”22.9 cm
6 3/4”17.1cm
9”22.9 cm
8”20.3 cm
HID
HID
FLO
OD
SFL
OO
DS
FF with GDFFinstalled
Finish:Chip and fade resistant metallic architecturalbronze or bright white polyester powder coating..
Spec Sheets, Installation Manuals,Wiring Diagrams & Photometrics 24/7www.rabweb.com > click “PRODUCTS”
Patents:The design of the Future Flood is protectedby U.S. Patent #D420458 and similar patentspending in China, Taiwan and Canada.
Effective Projected Area:Maximum EPA = .43
Photometrics
Replacement Lens:Mighty Post for ground installation:Chrome Plated Wire Guard:
FluorescentLamp supplied with fixture
Metal HalideLamp supplied with fixture
= Pulse Start
Catalog NumbersProduct InformationHigh Pressure SodiumLamp supplied with fixture
FF CFL
• SAVE ENERGY $$• LONGER LAMP LIFE• FASTER START TIME• BETTER LUMEN MAINTENANCE• LAMPS REMAIN SAME COLOR• COLD STARTING TO -40º
Metal Halide
5070
100
FFH50WFFH70W
*FFH100W/277
FFH50FFH70
*FFH100/277*100 watt Metal Halide is 277 volt only
LCFL42 BCFL42Triple
MountingHeight Multiplier
8’10’12’16’20’
1.61.0.7.4
.25
MultiplierWatts HPS MH CFL
.6
.4
.2
.2
150100
70503542
1.6.4.3
.15
1
Multiples of Distance to Sign/Wall
MountingHeight Multiplier
1.5.3
MultiplierWatts HPS MH CFL
.6
.4
.2
.2
150100
70503542
1.6.4.3
.15
6’9’
12’
Replacement Lamps Ballasts
BMHN50BMHN70BMHN100/277V
HID FLOODSHID FLOODSFUTUREFUTURE FLOODFLOOD™
EZ Grip Locknut matches fixture finish and can be adjusted with fingers, pliers or screwdriver
LFFMPM19 - see Pg. 110-111 for detailsGDFF
Electronic QT
/PC/PCS
Watts
RAB® TEL 888 RAB 1000FAX 888 RAB 1232www.rabweb.com RAB®TEL 888 RAB 1000
FAX 888 RAB 1232www.rabweb.com
LampANSI
Preferred by contractors for reliability, quality features and ease of installation.
2
1
Variable beam spread with 2 position adjustable socket
Mounting arm with sturdy locking teeth & internal gasket
Precision die cast aluminum housing with durable polyester powder coat finish
Long life lamp included Narrow Beamin Position 1Factory Setting
Wide Beamin Position 2
1
2
Weight:
MH50MH70MH100
67789
898
Fixture lbs Fixture lbs
HPS35HPS50HPS70HPS100HPS150
Easy Clip for tool-less relamping with vandalproof screw capability
Integra Hood Glare Shield for Friendly Lighting when properly aimed Sharp Light
CutoffLine
Silicone gasket stays in place for durableweatherproofing & easy relamping
Future Flood Integra Hood
Other fixtureswith no hood
Factory Installed OptionsAdd suffix to catalog number
Accessories for Field Installation:
4 3 2 1 0 1 2 3 4
01
2
3
4
5
5 fc2 fc
1 fc
0.2 fc
4 3 2 1 0 1 2 3 4
p g
Isofootcandle Diagram
5
4
3
2
1
0
13fc 50fc
105fc
4fc
Multiples of Distance to Sign/Wall(2' multiples)
Compact, tough and good lookingcast aluminum housing with hingedframed glass lens. Integra Hoodglare shield and stainless steel clip.35 to 150 watt HPS Metal HalidePulse Start. 50 & 70 watt with 120vreactor ballast or 100w with 277vNPF ballast. Lamp included.
/PC/PCS
/PC/PCS
/PC/PCS
FF HPS & MH
LampType
Lamp Base Ballast Bronze White White
Starting Amps / Operating Amps
ED17ED17ED17
MedMedMed
2 / 1.62.5 / 2.1Available in 277 volt only .7 / .5
LMH50LMH70LMH100
Bronze120V 208V 240V 277V
1.4 / 0.91.8 / 1.22.1 / 1.63.1 / 2.14.5 / 3.2
355070
100150
ED17ED17ED17ED17ED17
FF35FF50FF70FF100FF150
FF35WFF50WFF70WFF100WFF150W
FF42QT FF42QTW
Finish: Architectural BronzeWhite
Finish: Architectural BronzeWhite
UL Listing:Suitable for wet locations. Suitable formounting within 4’ of the ground.
Housing:Precision die cast aluminum, 1/2” NPSthreaded arm with locking swivel fits allstandard mounting boxes.
Reflector:Anodized semi-specular aluminum
Lens:Thermal tempered shock resistant glass
Lens Gasket:High temperature tubular silicone set in diecast retaining groove remains in place during relamping.
Socket:Glazed porcelain 4kv pulse rated with nickel plated screw shell and spring contacts.
GDFF
Finish: Chrome plated steel
Sign & Wall Lighting 150w HPS @ 6’ from wall - 30º above horizontal
Multiples of Mounting Height
Order fixture+ order GDFF guard
Order fixture+ order GDFF guard
BMHN50BMHN70BMHN100/277*
LHPS35LHPS50LHPS70LHPS100LHPS150
BHPSN35BHPSN50BHPSN70BHPSN100BHPSN150
GX24q-442 .4 .3 .2 .2
79
8”20.3 cm
The popular choice for reliable security.
78
MedMedMedMedMed
R-NPF 120VR-NPF 120VR-NPF 120VR-NPF 120VR-NPF 120V
Input Watts
InitialLumens
LampHours
24,00024,00024,00024,00024,000
7294
129
46
3,4005,6009,000
3,200
10,00015,00015,000
12,000
2,2504,0006,4009,500
16,000
466286
115170
M110M98M90
S76S68S62S54S55
150w HPS @ 10’ Mounting HeightAimed 30º below horizontal
6 3/4”17.1cm
*100 watt Metal Halide is 277 volt only
DimensionsSpecifications
FF GuardHeavy duty chrome plated steelwire guard prevents damage andvandalism. Easily field installable.Also fits QF500F Quartz flood.
White light in a compact package.Compact Fluorescent 42 watt withquad tap electronic ballast. Lamp included.
Button PhotocontrolSwivel Photocontrol
9”22.9 cm
6 3/4”17.1cm
9”22.9 cm
8”20.3 cm
HID
HID
FLO
OD
SFL
OO
DS
FF with GDFFinstalled
Finish:Chip and fade resistant metallic architecturalbronze or bright white polyester powder coating..
Spec Sheets, Installation Manuals,Wiring Diagrams & Photometrics 24/7www.rabweb.com > click “PRODUCTS”
Patents:The design of the Future Flood is protectedby U.S. Patent #D420458 and similar patentspending in China, Taiwan and Canada.
Effective Projected Area:Maximum EPA = .43
Photometrics
Replacement Lens:Mighty Post for ground installation:Chrome Plated Wire Guard:
FluorescentLamp supplied with fixture
Metal HalideLamp supplied with fixture
= Pulse Start
Catalog NumbersProduct InformationHigh Pressure SodiumLamp supplied with fixture
FF CFL
• SAVE ENERGY $$• LONGER LAMP LIFE• FASTER START TIME• BETTER LUMEN MAINTENANCE• LAMPS REMAIN SAME COLOR• COLD STARTING TO -40º
Metal Halide
5070
100
FFH50WFFH70W
*FFH100W/277
FFH50FFH70
*FFH100/277*100 watt Metal Halide is 277 volt only
LCFL42 BCFL42Triple
MountingHeight Multiplier
8’10’12’16’20’
1.61.0.7.4
.25
MultiplierWatts HPS MH CFL
.6
.4
.2
.2
150100
70503542
1.6.4.3
.15
1
Multiples of Distance to Sign/Wall
MountingHeight Multiplier
1.5.3
MultiplierWatts HPS MH CFL
.6
.4
.2
.2
150100
70503542
1.6.4.3
.15
6’9’
12’
Replacement Lamps Ballasts
BMHN50BMHN70BMHN100/277V
HID FLOODSHID FLOODSFUTUREFUTURE FLOODFLOOD™
EZ Grip Locknut matches fixture finish and can be adjusted with fingers, pliers or screwdriver
LFFMPM19 - see Pg. 110-111 for detailsGDFF
Electronic QT
/PC/PCS
Watts
RAB® TEL 888 RAB 1000FAX 888 RAB 1232www.rabweb.com RAB®TEL 888 RAB 1000
FAX 888 RAB 1232www.rabweb.com
LampANSI
Preferred by contractors for reliability, quality features and ease of installation.
2
1
Variable beam spread with 2 position adjustable socket
Mounting arm with sturdy locking teeth & internal gasket
Precision die cast aluminum housing with durable polyester powder coat finish
Long life lamp included Narrow Beamin Position 1Factory Setting
Wide Beamin Position 2
1
2
Weight:
MH50MH70MH100
67789
898
Fixture lbs Fixture lbs
HPS35HPS50HPS70HPS100HPS150
Easy Clip for tool-less relamping with vandalproof screw capability
Integra Hood Glare Shield for Friendly Lighting when properly aimed Sharp Light
CutoffLine
Silicone gasket stays in place for durableweatherproofing & easy relamping
Future Flood Integra Hood
Other fixtureswith no hood