pg.70-71(hid -future f)x (page 1) - frontier lighting · rab lighting, inc. š 170 ludlow aveš...

5
FF150 JOB NAME: DATE: TYPE: DESCRIPTION Compact, tough and good looking cast aluminum housing with hinged framed glass lens. Integra Hood glare shield and stainless steel clip. 35 to 150 watt HPS Metal Halide Pulse Start. 50 & 70 watt with 120v reactor ballast or 100W with 277V NPF ballast. Lamp included. SPECIFICATIONS Finish: Chip and fade resistant polyester powder coating Housing: Precision die cast aluminum, 1/2" NPS threaded arm with locking swivel fits all standard mounting boxes Lens Gasket: High temperature tubular silicone set in die cast retaining groove remains in place during relamping Lens: Thermal tempered shock resistant glass Reflector: Anodized semi-specular aluminum Socket: Glazed porcelain 4kv pulse rated with nickel plated screw shell and spring contacts Sockets: Porcelain with all copper current carrying components UL Listing: Suitable for wet locations. Suitable for mounting within 4' of the ground EPA: 0.43 Patents: Pat. D420,458 Color: Bronze Weight: 8.42 DIMENSIONS PHOTOMETRIC ORDERING INFORMATION High Pressure Sodium Total Watts Lamp Type Lamp Base Ballast Starting Amps/ Operating Amps 120V 208V 240V 277V Input Watts LAMP ANSI Initial Lumens Lamp Hours Lamp supplied with fixture 150 ED17 Medium R-NPF 120V 4.5/3.2 170 S55 16000 24000 Factory Installed Options Add suffix to Catalog Number Swivel Photocontrol (/PCS) Single fusing for 120 and 277 volt (/F) Double fusing for 208 and 240 volt. (/FF) Button Photocontrol (/PC) RAB Lighting, Inc. • 170 Ludlow Ave• Northvale, NJ 07647 • Tel: 888 RAB-1000 • Fax: 888 RAB-1232 • www.rabweb.com © 2007 Note: Specifications may change without notice

Upload: lenhu

Post on 19-Aug-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

FF150

JOB NAME:

DATE:

TYPE:

DESCRIPTIONCompact, tough and good looking cast aluminum housing with hinged framed glass lens.Integra Hood glare shield and stainless steel clip. 35 to 150 watt HPS Metal Halide PulseStart. 50 & 70 watt with 120v reactor ballast or 100W with 277V NPF ballast. Lampincluded.

SPECIFICATIONSFinish:Chip and fade resistant polyester powdercoating

Housing:Precision die cast aluminum, 1/2" NPSthreaded arm with locking swivel fits allstandard mounting boxes

Lens Gasket:High temperature tubular silicone set in diecast retaining groove remains in placeduring relamping

Lens:Thermal tempered shock resistant glassReflector:Anodized semi-specular aluminum

Socket:Glazed porcelain 4kv pulse rated with nickelplated screw shell and spring contacts

Sockets:Porcelain with all copper current carryingcomponents

UL Listing:Suitable for wet locations. Suitable formounting within 4' of the ground

EPA:0.43Patents:Pat. D420,458Color:BronzeWeight:8.42

DIMENSIONS

PHOTOMETRIC

ORDERING INFORMATIONHigh Pressure Sodium Total

WattsLamp Type

Lamp Base Ballast

Starting Amps/ Operating Amps120V 208V 240V 277V

Input Watts

LAMP ANSI

Initial Lumens

Lamp HoursLamp supplied with fixture

150 ED17 Medium R-NPF 120V 4.5/3.2 170 S55 16000 24000

Factory Installed OptionsAdd suffix to Catalog Number

Swivel Photocontrol (/PCS)Single fusing for 120 and 277 volt (/F)

Double fusing for 208 and 240 volt. (/FF)Button Photocontrol (/PC)

RAB Lighting, Inc. • 170 Ludlow Ave• Northvale, NJ 07647 • Tel: 888 RAB-1000 • Fax: 888 RAB-1232 • www.rabweb.com© 2007

Note: Specifications may change without notice

FUTURE FLOOD INSTALLATION INSTRUCTIONS

IMPORTANTREAD CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.

WARNING: Make certain power is OFF before installing or maintaining fixture.

Thank you for buying RAB lighting fixtures. Our aim is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000, or email: [email protected]

LOCATIONSecure the Future Flood to any 1/2” NPS hole in a metal plate coverplate, junction box or landscape post. Plug all unused holes and seal threads with silicone.

The swivel arm on the Future Flood allows 150º of vertical aiming adjustment.

Do not aim fixture to any object closer than 18 inches.

LAMP INSTALLATIONCAUTION: Prior to installing, check that the lamp is the correct ANSI type and wattage. Observe lamp manufacturer’s recommendations on lamp operation, ballast type and burning positions.

Disconnect power. Make sure fixture and lamp are cool enough to touch.

Remove screw from the door clip on the top of the fixture. Open fixture, swing door down on hinges.

Fully insert lamp into socket.

Before closing door, make sure frame gasket is properly seated all around the fixture.

Close door. Replace screw on door clip, if desired.

1.

2.

3.

1.

2.

3.

4.

5.

WIRINGDo not use any supply voltage other than those specified below: FF35-FF150 HPS 120V only FFH50-70 MH 120V only FFH100/277V 277V only FF42QT 120V thru 277V*

*No internal wiring changes needed for various voltages as the ballast is quad tap electronic.

Connect the black fixture lead to the (+) LINE supply lead.

Connect the white fixture lead to the (-) COMMON supply lead.

Connect the bare copper Ground wire from fixture to supply ground.

1.

2.

3.

CLEANING & MAINTENANCE CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.

Clean glass lens with non-abrasive glass cleaning solution.

As lamps age, light output diminishes. Mass relamping at regular intervals ensures full light output at the highest efficiency.

1.

2.

FUTURE FLOOD INSTALLATION INSTRUCTIONS

TROUBLESHOOTING Is the proper lamp is installed? Check the wattage and ANSI code on the fixture label against markings on the lamp. Refer to Replacement Lamp table above for verification.

Make sure the lamp is not defective. Try a lamp known to be in operating condition.

Check that the line voltage at fixture is correct. Refer to wiring directions.

Is there voltage at the lamp socket? If there is no voltage, check all connections.

Is the fixture is grounded properly?

Is the photocell is functioning properly (if used)?

1.

2.

3.

4.

5.

6.

ACCESSORIES AND REPLACEMENT PARTSChrome Wire Guard: GDFF Door and Frame with Glass: LFF (bronze) LFFW (white)Swivel Arm: FFLARMA (bronze) FFLARMW (white)Factory Installed Photocell: “/PC” (120V) “/PC2” (277V) “/PCS” (Swivel 120V)

Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.

FF-IN-0407

REPLACEMENT LAMPS AND BALLASTS Lamp ANSI Ballast Wattage Catalog# Code Catalog#High Pressure Sodium35 LHPS35 S76 BHPSN3550 LHPS50 S68 BHPSN5070 LHPS70 S62 BHPSN70 100 LHPS100 S54 BHPSN100 150 LHPS150 S55 BHPSN150Metal Halide50 LMH50 M110 BMHN5070 LMH70 M98 BMHN70 100 LMH100 M90 BMHN100/277Compact Fluorescent Base Type42 LCFL42 GX24q-4 BCLF42

GUARD INSTALLATION

Slide top and bottom ends of one side of guard into notches in the door frame.

Squeeze guard and slide the other ends of the guard into notches on the opposite side of the frame.

1.

2.

Slide end of guard into notch

Factory Installed OptionsAdd suffix to catalog number

Accessories for Field Installation:

4 3 2 1 0 1 2 3 4

01

2

3

4

5

5 fc2 fc

1 fc

0.2 fc

4 3 2 1 0 1 2 3 4

p g

Isofootcandle Diagram

5

4

3

2

1

0

13fc 50fc

105fc

4fc

Multiples of Distance to Sign/Wall(2' multiples)

Compact, tough and good lookingcast aluminum housing with hingedframed glass lens. Integra Hoodglare shield and stainless steel clip.35 to 150 watt HPS Metal HalidePulse Start. 50 & 70 watt with 120vreactor ballast or 100w with 277vNPF ballast. Lamp included.

/PC/PCS

/PC/PCS

/PC/PCS

FF HPS & MH

LampType

Lamp Base Ballast Bronze White White

Starting Amps / Operating Amps

ED17ED17ED17

MedMedMed

2 / 1.62.5 / 2.1Available in 277 volt only .7 / .5

LMH50LMH70LMH100

Bronze120V 208V 240V 277V

1.4 / 0.91.8 / 1.22.1 / 1.63.1 / 2.14.5 / 3.2

355070

100150

ED17ED17ED17ED17ED17

FF35FF50FF70FF100FF150

FF35WFF50WFF70WFF100WFF150W

FF42QT FF42QTW

Finish: Architectural BronzeWhite

Finish: Architectural BronzeWhite

UL Listing:Suitable for wet locations. Suitable formounting within 4’ of the ground.

Housing:Precision die cast aluminum, 1/2” NPSthreaded arm with locking swivel fits allstandard mounting boxes.

Reflector:Anodized semi-specular aluminum

Lens:Thermal tempered shock resistant glass

Lens Gasket:High temperature tubular silicone set in diecast retaining groove remains in place during relamping.

Socket:Glazed porcelain 4kv pulse rated with nickel plated screw shell and spring contacts.

GDFF

Finish: Chrome plated steel

Sign & Wall Lighting 150w HPS @ 6’ from wall - 30º above horizontal

Multiples of Mounting Height

Order fixture+ order GDFF guard

Order fixture+ order GDFF guard

BMHN50BMHN70BMHN100/277*

LHPS35LHPS50LHPS70LHPS100LHPS150

BHPSN35BHPSN50BHPSN70BHPSN100BHPSN150

GX24q-442 .4 .3 .2 .2

79

8”20.3 cm

The popular choice for reliable security.

78

MedMedMedMedMed

R-NPF 120VR-NPF 120VR-NPF 120VR-NPF 120VR-NPF 120V

Input Watts

InitialLumens

LampHours

24,00024,00024,00024,00024,000

7294

129

46

3,4005,6009,000

3,200

10,00015,00015,000

12,000

2,2504,0006,4009,500

16,000

466286

115170

M110M98M90

S76S68S62S54S55

150w HPS @ 10’ Mounting HeightAimed 30º below horizontal

6 3/4”17.1cm

*100 watt Metal Halide is 277 volt only

DimensionsSpecifications

FF GuardHeavy duty chrome plated steelwire guard prevents damage andvandalism. Easily field installable.Also fits QF500F Quartz flood.

White light in a compact package.Compact Fluorescent 42 watt withquad tap electronic ballast. Lamp included.

Button PhotocontrolSwivel Photocontrol

9”22.9 cm

6 3/4”17.1cm

9”22.9 cm

8”20.3 cm

HID

HID

FLO

OD

SFL

OO

DS

FF with GDFFinstalled

Finish:Chip and fade resistant metallic architecturalbronze or bright white polyester powder coating..

Spec Sheets, Installation Manuals,Wiring Diagrams & Photometrics 24/7www.rabweb.com > click “PRODUCTS”

Patents:The design of the Future Flood is protectedby U.S. Patent #D420458 and similar patentspending in China, Taiwan and Canada.

Effective Projected Area:Maximum EPA = .43

Photometrics

Replacement Lens:Mighty Post for ground installation:Chrome Plated Wire Guard:

FluorescentLamp supplied with fixture

Metal HalideLamp supplied with fixture

= Pulse Start

Catalog NumbersProduct InformationHigh Pressure SodiumLamp supplied with fixture

FF CFL

• SAVE ENERGY $$• LONGER LAMP LIFE• FASTER START TIME• BETTER LUMEN MAINTENANCE• LAMPS REMAIN SAME COLOR• COLD STARTING TO -40º

Metal Halide

5070

100

FFH50WFFH70W

*FFH100W/277

FFH50FFH70

*FFH100/277*100 watt Metal Halide is 277 volt only

LCFL42 BCFL42Triple

MountingHeight Multiplier

8’10’12’16’20’

1.61.0.7.4

.25

MultiplierWatts HPS MH CFL

.6

.4

.2

.2

150100

70503542

1.6.4.3

.15

1

Multiples of Distance to Sign/Wall

MountingHeight Multiplier

1.5.3

MultiplierWatts HPS MH CFL

.6

.4

.2

.2

150100

70503542

1.6.4.3

.15

6’9’

12’

Replacement Lamps Ballasts

BMHN50BMHN70BMHN100/277V

HID FLOODSHID FLOODSFUTUREFUTURE FLOODFLOOD™

EZ Grip Locknut matches fixture finish and can be adjusted with fingers, pliers or screwdriver

LFFMPM19 - see Pg. 110-111 for detailsGDFF

Electronic QT

/PC/PCS

Watts

RAB® TEL 888 RAB 1000FAX 888 RAB 1232www.rabweb.com RAB®TEL 888 RAB 1000

FAX 888 RAB 1232www.rabweb.com

LampANSI

Preferred by contractors for reliability, quality features and ease of installation.

2

1

Variable beam spread with 2 position adjustable socket

Mounting arm with sturdy locking teeth & internal gasket

Precision die cast aluminum housing with durable polyester powder coat finish

Long life lamp included Narrow Beamin Position 1Factory Setting

Wide Beamin Position 2

1

2

Weight:

MH50MH70MH100

67789

898

Fixture lbs Fixture lbs

HPS35HPS50HPS70HPS100HPS150

Easy Clip for tool-less relamping with vandalproof screw capability

Integra Hood Glare Shield for Friendly Lighting when properly aimed Sharp Light

CutoffLine

Silicone gasket stays in place for durableweatherproofing & easy relamping

Future Flood Integra Hood

Other fixtureswith no hood

Factory Installed OptionsAdd suffix to catalog number

Accessories for Field Installation:

4 3 2 1 0 1 2 3 4

01

2

3

4

5

5 fc2 fc

1 fc

0.2 fc

4 3 2 1 0 1 2 3 4

p g

Isofootcandle Diagram

5

4

3

2

1

0

13fc 50fc

105fc

4fc

Multiples of Distance to Sign/Wall(2' multiples)

Compact, tough and good lookingcast aluminum housing with hingedframed glass lens. Integra Hoodglare shield and stainless steel clip.35 to 150 watt HPS Metal HalidePulse Start. 50 & 70 watt with 120vreactor ballast or 100w with 277vNPF ballast. Lamp included.

/PC/PCS

/PC/PCS

/PC/PCS

FF HPS & MH

LampType

Lamp Base Ballast Bronze White White

Starting Amps / Operating Amps

ED17ED17ED17

MedMedMed

2 / 1.62.5 / 2.1Available in 277 volt only .7 / .5

LMH50LMH70LMH100

Bronze120V 208V 240V 277V

1.4 / 0.91.8 / 1.22.1 / 1.63.1 / 2.14.5 / 3.2

355070

100150

ED17ED17ED17ED17ED17

FF35FF50FF70FF100FF150

FF35WFF50WFF70WFF100WFF150W

FF42QT FF42QTW

Finish: Architectural BronzeWhite

Finish: Architectural BronzeWhite

UL Listing:Suitable for wet locations. Suitable formounting within 4’ of the ground.

Housing:Precision die cast aluminum, 1/2” NPSthreaded arm with locking swivel fits allstandard mounting boxes.

Reflector:Anodized semi-specular aluminum

Lens:Thermal tempered shock resistant glass

Lens Gasket:High temperature tubular silicone set in diecast retaining groove remains in place during relamping.

Socket:Glazed porcelain 4kv pulse rated with nickel plated screw shell and spring contacts.

GDFF

Finish: Chrome plated steel

Sign & Wall Lighting 150w HPS @ 6’ from wall - 30º above horizontal

Multiples of Mounting Height

Order fixture+ order GDFF guard

Order fixture+ order GDFF guard

BMHN50BMHN70BMHN100/277*

LHPS35LHPS50LHPS70LHPS100LHPS150

BHPSN35BHPSN50BHPSN70BHPSN100BHPSN150

GX24q-442 .4 .3 .2 .2

79

8”20.3 cm

The popular choice for reliable security.

78

MedMedMedMedMed

R-NPF 120VR-NPF 120VR-NPF 120VR-NPF 120VR-NPF 120V

Input Watts

InitialLumens

LampHours

24,00024,00024,00024,00024,000

7294

129

46

3,4005,6009,000

3,200

10,00015,00015,000

12,000

2,2504,0006,4009,500

16,000

466286

115170

M110M98M90

S76S68S62S54S55

150w HPS @ 10’ Mounting HeightAimed 30º below horizontal

6 3/4”17.1cm

*100 watt Metal Halide is 277 volt only

DimensionsSpecifications

FF GuardHeavy duty chrome plated steelwire guard prevents damage andvandalism. Easily field installable.Also fits QF500F Quartz flood.

White light in a compact package.Compact Fluorescent 42 watt withquad tap electronic ballast. Lamp included.

Button PhotocontrolSwivel Photocontrol

9”22.9 cm

6 3/4”17.1cm

9”22.9 cm

8”20.3 cm

HID

HID

FLO

OD

SFL

OO

DS

FF with GDFFinstalled

Finish:Chip and fade resistant metallic architecturalbronze or bright white polyester powder coating..

Spec Sheets, Installation Manuals,Wiring Diagrams & Photometrics 24/7www.rabweb.com > click “PRODUCTS”

Patents:The design of the Future Flood is protectedby U.S. Patent #D420458 and similar patentspending in China, Taiwan and Canada.

Effective Projected Area:Maximum EPA = .43

Photometrics

Replacement Lens:Mighty Post for ground installation:Chrome Plated Wire Guard:

FluorescentLamp supplied with fixture

Metal HalideLamp supplied with fixture

= Pulse Start

Catalog NumbersProduct InformationHigh Pressure SodiumLamp supplied with fixture

FF CFL

• SAVE ENERGY $$• LONGER LAMP LIFE• FASTER START TIME• BETTER LUMEN MAINTENANCE• LAMPS REMAIN SAME COLOR• COLD STARTING TO -40º

Metal Halide

5070

100

FFH50WFFH70W

*FFH100W/277

FFH50FFH70

*FFH100/277*100 watt Metal Halide is 277 volt only

LCFL42 BCFL42Triple

MountingHeight Multiplier

8’10’12’16’20’

1.61.0.7.4

.25

MultiplierWatts HPS MH CFL

.6

.4

.2

.2

150100

70503542

1.6.4.3

.15

1

Multiples of Distance to Sign/Wall

MountingHeight Multiplier

1.5.3

MultiplierWatts HPS MH CFL

.6

.4

.2

.2

150100

70503542

1.6.4.3

.15

6’9’

12’

Replacement Lamps Ballasts

BMHN50BMHN70BMHN100/277V

HID FLOODSHID FLOODSFUTUREFUTURE FLOODFLOOD™

EZ Grip Locknut matches fixture finish and can be adjusted with fingers, pliers or screwdriver

LFFMPM19 - see Pg. 110-111 for detailsGDFF

Electronic QT

/PC/PCS

Watts

RAB® TEL 888 RAB 1000FAX 888 RAB 1232www.rabweb.com RAB®TEL 888 RAB 1000

FAX 888 RAB 1232www.rabweb.com

LampANSI

Preferred by contractors for reliability, quality features and ease of installation.

2

1

Variable beam spread with 2 position adjustable socket

Mounting arm with sturdy locking teeth & internal gasket

Precision die cast aluminum housing with durable polyester powder coat finish

Long life lamp included Narrow Beamin Position 1Factory Setting

Wide Beamin Position 2

1

2

Weight:

MH50MH70MH100

67789

898

Fixture lbs Fixture lbs

HPS35HPS50HPS70HPS100HPS150

Easy Clip for tool-less relamping with vandalproof screw capability

Integra Hood Glare Shield for Friendly Lighting when properly aimed Sharp Light

CutoffLine

Silicone gasket stays in place for durableweatherproofing & easy relamping

Future Flood Integra Hood

Other fixtureswith no hood