pev performance verification system - team 14026 kristeen yee - team leader, stephanie zambito,...

12
PEV Performance Verification System - Team 14026 Kristeen Yee - Team Leader, Stephanie Zambito, Soham Chakraborty, Leslie Havens, Danielle Koch, Mike Allocco, Andrew Miller

Upload: mervyn-gaines

Post on 24-Dec-2015

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PEV Performance Verification System - Team 14026 Kristeen Yee - Team Leader, Stephanie Zambito, Soham Chakraborty, Leslie Havens, Danielle Koch, Mike Allocco,

PEV Performance Verification System - Team 14026Kristeen Yee - Team Leader, Stephanie Zambito, Soham Chakraborty, Leslie Havens, Danielle Koch, Mike Allocco, Andrew Miller

Page 2: PEV Performance Verification System - Team 14026 Kristeen Yee - Team Leader, Stephanie Zambito, Soham Chakraborty, Leslie Havens, Danielle Koch, Mike Allocco,

Agenda

● Project Background● Problem Statement & Project

Deliverables● Use Scenarios● Benchmarking of other testers● Prioritized Needs● Engineering Requirements● Draft of Project Plans

Team 14026 – Sept 12, 2013

Page 3: PEV Performance Verification System - Team 14026 Kristeen Yee - Team Leader, Stephanie Zambito, Soham Chakraborty, Leslie Havens, Danielle Koch, Mike Allocco,

What is a PEV?

● Portable Emergency Ventilator that provides positive pressure to a person that is incapable of breathing on their own.

Team 14026 – Sept 12, 2013

Page 4: PEV Performance Verification System - Team 14026 Kristeen Yee - Team Leader, Stephanie Zambito, Soham Chakraborty, Leslie Havens, Danielle Koch, Mike Allocco,

Previous PEV Prototypes

● MEDIRESP III○ Portable ventilator that does not use an

oxygen tank○ 4 modes of air flow

● MEDIRESP IV○ A digital system

● MEDIRESP V○ Attempting to make it lighter, more compact,

and user friendly

Team 14026 – Sept 12, 2013

Page 5: PEV Performance Verification System - Team 14026 Kristeen Yee - Team Leader, Stephanie Zambito, Soham Chakraborty, Leslie Havens, Danielle Koch, Mike Allocco,

Problem Statement● Current State

○ 1st generation of a verification system● Desired State

○ Simulate the respiratory system and measure flow, pressure, volume, and oxygen concentration

● Project Goals/Opportunities○ Collect data to evaluate PEV prototypes○ Develop database of analytic results

● Constraints○ ANSI Z79.7 - Standards for Breathing

Machines for Medical Use○ ISO 5469:1967 - Adult lung and Infant lung○ ASTM F 1100-90 - Ventilators Intended for

Use in Critical CareTeam 14026 – Sept 12, 2013

Page 6: PEV Performance Verification System - Team 14026 Kristeen Yee - Team Leader, Stephanie Zambito, Soham Chakraborty, Leslie Havens, Danielle Koch, Mike Allocco,

Project Deliverables

● Functional test fixture that simulates an active lung

● Test data verifying operation● Design alternatives:

○ Calibration techniques

http://enterprise1.astm.org/DOWNLOAD/F1100-WITHDRAWN.1565472-1.pdfTeam 14026 – Sept 12, 2013

Page 7: PEV Performance Verification System - Team 14026 Kristeen Yee - Team Leader, Stephanie Zambito, Soham Chakraborty, Leslie Havens, Danielle Koch, Mike Allocco,

Stakeholders

● Hospitals● First responders● Doctors● Jeff Gutterman● Dr. Roman Press● Mary Murphy● Ed Hanzlik● MSD Team 13027● MSD Team 14026

Team 14026 – Sept 12, 2013

Page 8: PEV Performance Verification System - Team 14026 Kristeen Yee - Team Leader, Stephanie Zambito, Soham Chakraborty, Leslie Havens, Danielle Koch, Mike Allocco,

Use Scenarios Considered

● Scenario 1: To test the prototypes of the different PEV’s

● Scenario 2: Potential use for quality control in a manufacturing setting

Team 14026 – Sept 12, 2013

Page 9: PEV Performance Verification System - Team 14026 Kristeen Yee - Team Leader, Stephanie Zambito, Soham Chakraborty, Leslie Havens, Danielle Koch, Mike Allocco,

Benchmarking Other Testers● CITREX H4

○ mobile & useful for production plants○ completely digital

● FlowAnalyser PF-300○ measures PEEP and peak pressures○ more bulky than CITREX but also more

powerful○ $7650

● Certifier FA Plus Ventilator Test System 4080○ measures air, O2 , Air/O2 mixture,N2,CO2, and

N2O○ neonatal to adult, and high frequency

breathing○ $3465

http://www.imtmedical.com/en-us/products/mobiletestingdevices/citrexh4/Pages/specs.aspx#5Team 14026 – Sept 12, 2013

Page 10: PEV Performance Verification System - Team 14026 Kristeen Yee - Team Leader, Stephanie Zambito, Soham Chakraborty, Leslie Havens, Danielle Koch, Mike Allocco,

Matrix

Team 14026 – Sept 12, 2013

Page 11: PEV Performance Verification System - Team 14026 Kristeen Yee - Team Leader, Stephanie Zambito, Soham Chakraborty, Leslie Havens, Danielle Koch, Mike Allocco,

Preliminary Schedule

Team 14026 – Sept 12, 2013

Page 12: PEV Performance Verification System - Team 14026 Kristeen Yee - Team Leader, Stephanie Zambito, Soham Chakraborty, Leslie Havens, Danielle Koch, Mike Allocco,

Issues & Corrective Actions

● Research respiratory system in depth○ Meet with Dr Doolittle

■ Planned meeting on Friday, Sept 20○ Library & Literature Research

■ Books from Risa Robinson■ Keep open communication with Mr

Hanzlik for standards research● Develop Work Breakdown Structure

o Determine strengths of team memberso Determine subsections of project

development● Develop Risk Management

o Develop FMEA tableTeam 14026 – Sept 12, 2013