percutaneous closure of asds with relatively deficient ...€¦ · defects with deficient inferior...
TRANSCRIPT
![Page 1: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/1.jpg)
Percutaneous Closure of ASDs with Relatively Deficient Rims – Tips and
Tricks
Krishna Kumar
AIMS
Cochin
![Page 2: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/2.jpg)
Key Questions?
• Is percutaneous closure possible?
• Device size?
• Closure technique?
![Page 3: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/3.jpg)
Definition and Terminology
IVC
SVC
Asc
Aorta
TV cs
Superior
Inferior
Posterior
Anterior
![Page 4: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/4.jpg)
ASDs with adequate and minimal margins
![Page 5: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/5.jpg)
Atrial Septal Evaluation: TTE
S
I
A P
Deficient inferior
rim
Inferior rim:
absent Adequate superior
and inferior rims
![Page 6: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/6.jpg)
6
RA LA
RV
LV
RV
LV
RA cs
The Apical Views
Inferior sweeps
reveal posterior
structures
The apical
4 chamber
view
![Page 7: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/7.jpg)
Imaging the IVC Margin
•Sub-xiphoid views are also very useful provided there
are good acoustic windows
•Imaging through TEE requires special maneuvers
RA
LA
EV
![Page 8: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/8.jpg)
Imaging the IVC Margin through
conventional TEE: Why is it difficult?
CT chest: Mid-thoracic
![Page 9: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/9.jpg)
Imaging the IVC Margin through
conventional TEE: Why is it difficult?
Remadevi KS, Francis E, Kumar RK, Catheter closure of atrial septal
defects with deficient inferior vena cava rim under transesophageal echo
guidance, Cathet Cardiovasc. Interven. 2009, 73:90-96
![Page 10: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/10.jpg)
Imaging the IVC Margin through TEE:
The modified retroflexed view
Retroflexion moves probe away from heart and eliminates the parallel
orientation of the ultrasound beams to the atrial septum
Device
TEE
probe
Device
TEE probe
A B
![Page 11: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/11.jpg)
RA
LA
A
RA
LA
B
Conventional
Retroflexed
![Page 12: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/12.jpg)
RA
LA
RA
LA A
LA
RA
B
Conventional
Retroflexed
![Page 13: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/13.jpg)
Retroflexed
![Page 14: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/14.jpg)
RA
LA
Ao
posterior
anterior
![Page 15: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/15.jpg)
Choosing size of the device
• Balloon stretched diameter
– Unrealistic for large ASDs with minimal rims?
• Largest dimension on TEE
– + 2mm to be safe
– ± 1mm in small children
– + 4 mm • Deficient margins
• Floppy
• Adjacent defects
![Page 16: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/16.jpg)
Acceptable limits of device sizing
Children:
8-10 Kg: < 15 mm
10-15 Kg: < 20 mm
15-25 Kg: < 28-30 mm
Adults:
40-46 mm (Kannan BRJ, Anil SR, Sivakumar K, Kumar RK, Transcatheter closure of the very
large atrial septal defects using the Amplatzer septal occluder, Catheterization and Cardiovascular Interventions 2003;59:522-527)
![Page 17: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/17.jpg)
Device Deployment: Usual Sequence
![Page 18: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/18.jpg)
ASD with deficient rims: deployment not likely to be straightforward?
Poor alignment of assembly vs. plane of the defect
![Page 19: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/19.jpg)
Device Deployment Techniques to Ensure Rim Capture
Right atrial disc should form to the right of the septal plane before the left atrial disc can slip out
Rapid release
Hold on to the LA disc until RA disc is positioned
![Page 20: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/20.jpg)
What to do when deployment is not straightforward?
Rapid deployment using aortic root support
(Deficient aortic root margin)
![Page 21: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/21.jpg)
The left upper pulmonary vein approach
![Page 22: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/22.jpg)
The right upper pulmonary vein approach
ASDs with floppy or deficient posterior margins
![Page 23: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/23.jpg)
Catheter or Balloon-assisted deployment
Dalvi BV et al Catheter Cardiovasc Interv. 2005
Jan;64(1):102-7.
![Page 24: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/24.jpg)
Echo guided deployment
![Page 25: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/25.jpg)
Echo guided deployment
![Page 26: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/26.jpg)
Other “ Tricks”
Making the sheath “coaxial to the defect
•Hausdorf
•Fu-star
•Cutting away a part of the sheath (Latson technique)
![Page 27: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/27.jpg)
Assessment before release
![Page 28: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/28.jpg)
Testing device stability
![Page 29: Percutaneous Closure of ASDs with Relatively Deficient ...€¦ · defects with deficient inferior vena cava rim under transesophageal echo guidance, Cathet Cardiovasc. Interven](https://reader033.vdocuments.us/reader033/viewer/2022060801/6085dafb07e7b0024627b594/html5/thumbnails/29.jpg)
What Determines Results of
Catheter Closure of ASD?
Anatomy of defect
Patient characteristics
Equipment
Size Location Margins
Neighboring structures Associated lesions
Weight Age Co-morbidity
Echocardiography Devices
Delivery systems
Operator(s)
Imaging guidance Experience Hand-eye coordination