pds architecture inc. 12800 university dr. suite 402structural drawings shall be used in conjunction...
TRANSCRIPT
FT
MY
ER
S, F
L 33
907
1280
0 U
NIV
ER
SIT
Y D
R. S
UIT
E 4
02
FL
LIC
EN
SE
# A
A26
0024
74
PDS A
RCHI
TECT
URE I
NC.
FX
: 855
.835
.273
3P
H: 2
39.4
37.8
090
INF
O@
PD
Sin
conl
ine.
com
TITLE:
SHEET NO.
DATE:
JOB:
REVISIONS
ALL
IDE
AS
, DE
SIG
NS
, AN
D P
LAN
S IN
DIC
AT
ED
ON
OR
RE
PR
ES
EN
TE
D B
Y T
HE
SE
DO
CU
ME
NT
S A
RE
OW
NE
D B
Y A
ND
AR
E P
RO
PE
RT
Y O
F P
DS
AR
CH
ITE
CT
RU
E IN
C.
PD
S A
RC
HIT
EC
TR
UE
INC
. HE
RE
BY
EX
PR
ES
SLY
RE
SE
RV
ES
ITS
CO
PY
RIG
HT
AN
D O
TH
ER
PR
OP
ER
TY
RIG
HT
S IN
TH
ES
E D
OC
UM
EN
TS
. TH
ES
E P
LAN
S A
ND
DR
AW
ING
S A
RE
NO
T T
O B
E R
EP
RO
DU
CE
D, C
HA
NG
ED
OR
CO
PIE
D IN
AN
Y F
OR
M O
R M
AN
NE
R W
HA
TS
OE
VE
R W
ITH
OU
T F
IRS
T O
BT
AIN
ING
TH
E E
XP
RE
SS
WR
ITT
EN
PE
RM
ISS
ION
AN
D C
ON
SE
NT
OF
PD
S A
RC
HIT
EC
TR
UE
INC
., N
OR
AR
E T
HE
Y T
O B
E A
SS
IGN
ED
TO
AN
Y P
AR
TY
WIT
HO
UT
FIR
ST
OB
TA
ININ
G S
AID
WR
ITT
EN
CO
NS
EN
T.
©P
DS
AR
CH
ITE
CT
RU
E
INC
.
18-0100
5-17-19
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
FO
R
PO
RT
CH
AR
LOT
TE
, FL
3398
3
SELECT STRUCTURAL
SELECT STRUCTURAL12573 New Brittany Blvd
Fort Myers, Florida 33907
Phone: (239) 210-5090
Certification Auth. 28357
Project No. : 19217
1Issued for Bid10-17-19
S0.01Engineer: LG Drafter:JRA
GENERAL NOTES
GENERAL STRUCTURAL NOTES
GENERAL: DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE TYPICAL AND APPLY TO SIMILAR SITUATIONS ELSEWHERE, EXCEPT AS OTHERWISE INDICATED. ADAPT REQUIREMENTS OF DETAILS, SECTIONS, PLANS, AND NOTES AT LOCATIONS WHERE CONDITIONS ARE SIMILAR.
CENTER ALL FOOTINGS AND PIERS UNDER COLUMNS ABOVE UNLESS SPECIFICALLY DIMENSIONED OTHERWISE.
STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SITE DRAWINGS. CONSULT THESE DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS.
CONTRACTOR SHALL LOCATE ALL BURIED UTILITIES PRIOR TO EXCAVATION FOR BUILDING FOUNDATIONS. THE STRUCTURAL ENGINEER SHALL BE NOTIFIED OF POTENTIAL CONFLICTS BETWEEN FOUNDATIONS AND BURIED UTILITIES.
CODE REQUIREMENTS: THE BUILDING STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE 2017 6th EDITION OF THE FLORIDA BUILDING CODE. FOLLOW ALL APPLICABLE PROVISIONS FOR ALL PHASES OF CONSTRUCTION. ADDITIONS ARE IN COMPLIANCE WITH THE 2017 EDITION OF THE FLORIDA EXISTING BUILDING CODE.
SPECIAL INSPECTIONS: THIS BUILDING IS CLASSIFIED AS A “THRESHOLD BUILDING”. SPECIAL INSPECTION OF THE CONSTRUCTION IS REQUIRED BY THE STATE OF FLORIDA IN ACCORDANCE WITH CHAPTER 471 OF THE FLORIDA STATUTES. CONSTRUCTION SHALL BE INSPECTED IN ACCORDANCE WITH THE SPECIAL INSPECTION PLAN.
FORMWORK, SHORING, AND RESHORING IS REQUIRED TO BE REVIEWED BY THE SHORING DESIGN ENGINEER AND A LETTER STATING COMPLIANCE WITH THEIR INTENT SHALL BE SUBMITTED TO THE THRESHOLD INSPECTOR PRIOR TO CONCRETE PLACEMENT.
TEMPORARY CONDITIONS: THE STRUCTURAL INTEGRITY OF THE COMPLETED STRUCTURE DEPENDS ON INTERACTION OF VARIOUS CONNECTED COMPONENTS. PROVIDE ADEQUATE BRACING, SHORING, AND OTHER TEMPORARY SUPPORTS AS REQUIRED TO SAFELY COMPLETE THE WORK. THE STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR STABILITY UNDER FINAL CONFIGURATION ONLY.
DESIGN CRITERIA: DESIGN WAS BASED ON STRENGTH AND DEFLECTION CRITERIA OF THE 2017 FLORIDA BUILDING CODE. IN ADDITION TO THE DEAD LOADS, THE FOLLOWING LOADS AND ALLOWABLES WERE USED FOR DESIGN, WITH LIVE LOADS REDUCED PER THE 2017 FBC:
ROOF: 20 PSF LL 30 PSF SDL
FLOORS: RESIDENTIAL 40 PSF LL 20 PSF SDLSTAIRS 100 PSF LL
NOTE: LOADING ABOVE INCLUDES 5 PSF FOR SPRINKLER PIPING
WIND SPEED 150 MPH PER CHAPTER 26 ASCE 7-10116 MPH NOMINAL
RISK CATEGORY II EXPOSURE CINTERNAL PRESSURE COEFF +/- 0.18 ENCLOSED
OPENINGS BELOW 60 FEET SHALL BE PROTECTED FROM WIND BORNE DEBRIS PER FBC 2017 AND ASCE 7-10 REQUIREMENTS.
FOUNDATIONS: THE GEOTECHNICAL REPORT PREPARED BY: ECS FLORIDA, LLC PROJECT NUMBER: 60:1074 DATED: JANUARY 11, 2019, REVISED FEBRUARY 1, 2019 RECOMMEND FOUNDATION DESIGN WITH AN ALLOWABLE SOIL BEARING PRESSURE FOR SHALLOW FOUNDATIONS OF 5000 PSF. FOUNDATION DESIGN IS BASED ON AN ALLOWABLE SOIL BEARING PRESSURE OF 3000 PSF. CONTRACTOR SHALL FOLLOW THE RECOMMENDATIONS SPECIFIED IN THE GEOTECHNICAL REPORT INCLUDING, BUT NOT LIMITED TO, SUBGRADE PREPARATIONS AND FOUNDATION INSTALLATION. THE GEOTECHNICAL ENGINEER SHALL EXAMINE THE EXCAVATION TO VERIFY SOIL CONDITIONS AND BEARING PRESSURE PRIOR TO PLACEMENT OF CONCRETE.
SUBMITTALS: SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO FABRICATION AND CONSTRUCTION REGARDING ALL STRUCTURAL ITEMS INCLUDING THE FOLLOWING: CONCRETE MIX DESIGNS, CONCRETE AND MASONRY REINFORCING, EMBEDDED STEEL ITEMS, AND STRUCTURAL STEEL. SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTOR PRIOR TO SUBMITTAL TO THE ARCHITECT/ENGINEER. DRAWINGS SUBMITTED WITHOUT REVIEW WILL BE RETURNED UNCHECKED. IF THE SHOP DRAWINGS DIFFER FROM OR ADD TO THE DESIGN OF THE STRUCTURAL DRAWINGS, THEY SHALL BEAR THE SEAL AND SIGNATURE OF A STRUCTURAL ENGINEER REGISTERED IN THE STATE OF FLORIDA. ANY CHANGES TO THE STRUCTURAL DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT AND ARE SUBJECT TO THE REVIEW AND ACCEPTANCE OF THE ENGINEER.
DESIGN DRAWINGS, SHOP DRAWINGS, AND CALCULATIONS FOR THE DESIGN AND FABRICATION OF ITEMS THAT ARE DESIGNED BY OTHERS, INCLUDING: PRECAST PRESTRESSED CONCRETE MEMBERS, STRUCTURAL STEEL CONNECTIONS, STAIRS, COLD FORMED METAL STUDS, MECHANICAL SCREEN ENCLOSURE, AND ALUMINUM CANOPIES SHALL BEAR THE SEAL AND SIGNATURE OF A STRUCTURAL ENGINEER REGISTERED IN THE STATE OF FLORIDA, AND SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO FABRICATION. CALCULATIONS SHALL BE INCLUDED FOR ALL CONNECTIONS TO THE STRUCTURE, CONSIDERING LOCALIZED EFFECTS ON THE STRUCTURAL ELEMENTS INDUCED BY THE CONNECTION LOADS. DESIGN SHALL BE BASED ON THE REQUIREMENTS OF THE 2017 FBC.
SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGN INTENT OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC. CONTRACTOR SHALL NOT BE RELIEVED FROM RESPONSIBILITY FOR ERRORS OR OMISSIONS IN SHOP DRAWINGS OR MIX DESIGNS BY THE ENGINEER’S REVIEW.
CONCRETE: REINFORCED CONCRETE CONSTRUCTION SHALL CONFORM TO THE FBC AND ACI 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE". CONCRETE STRENGTHS SHALL BE VERIFIED BY STANDARD 28-DAY CYLINDER TESTS PER ASTM C39, AND SHALL BE AS FOLLOWS:
f’c USE3000 PSI FOUNDATIONS/SLAB ON GRADE4000 PSI ALL USES, U.N.O.
CEMENT SHALL CONFORM TO ASTM C150, TYPE 1. FLY ASH CONFORMING TO ASTM C618, TYPE F OR TYPE C, MAY BE USED TO REPLACE UP TO 20% OF THE CEMENT CONTENT, PROVIDED THAT THE MIX STRENGTH IS SUBSTANTIATED BY TEST DATA. COARSE AGGREGATE SHALL CONFORM TO ASTM C33 WITH A MAXIMUM SIZE OF 3/4". FINE AGGREGATE SHALL BE CLEAN, DURABLE, NATURAL SAND CONFORMING TO ASTM C33.
A WATER-REDUCING ADMIXTURE, IF USED, SHALL CONFORM TO ASTM C494 AND USED IN STRICT ACCORDANCE WITH THE MANUFACTURER’S RECOMMENDATIONS, SHALL BE INCORPORATED IN CONCRETE DESIGN MIXES. A HIGH-RANGE WATER-REDUCING ADMIXTURE CONFORMING TO ASTM C494, TYPE F OR G, MAY BE USED IN CONCRETE MIXES, PROVIDING THAT THE SLUMP DOES NOT EXCEED 8”.
SLEEVES, OPENINGS, CONDUIT, AND OTHER EMBEDDED ITEMS NOT SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE APPROVED BY THE STRUCTURAL ENGINEER BEFORE POURING. NO SLEEVE, OPENING, OR INSERT MAY BE PLACED IN BEAMS, JOISTS, OR COLUMNS UNLESS APPROVED BY THE ENGINEER. CONDUITS EMBEDDED IN SLABS SHALL NOT BE LARGER IN OUTSIDE DIMENSION THAN ONE THIRD OF THE THICKNESS OF THE SLAB AND SHALL NOT BE SPACED CLOSER THAN THREE DIAMETERS ON CENTER.
PROVIDE 3/4” CHAMFERS ON ALL EXPOSED CONCRETE EDGES, UNLESS NOTED OTHERWISE. WHERE INDICATED OR REQUIRED, SLOPE CONCRETE SLABS TO DRAINS SHOWN ON PLUMBING AND/OR ARCHITECTURAL DRAWINGS.
ALL CONCRETE SHALL BE CURED IMMEDIATELY AFTER FINISHING OPERATIONS.
SHORING AND RESHORING: THE FORM AND SHORING SYSTEM SHALL BE DESIGNED BY A FLORIDA REGISTERED ENGINEER IN ACCORDANCE WITH ACI 347R RECOMMENDED PRACTICE FOR CONCRETE FORMING.
SHORING AND RESHORING PLANS SHALL BE SIGNED AND SEALED AND SUBMITTED WITH CALCULATIONS. CALCULATIONS FOR THE RE-SHORING PROCESS SHALL INCLUDE THE POURING AND STRIPPING CYCLE BASED ON THE CONSTRUCTION SCHEDULE. THE ASSUMED CONCRETE STRENGTH AT THE TIME OF STRIPPING SHALL BE SUBSTAINTIATED BY FIELD TESTING.
CONVENTIALLY REINFORCED FLAT SLAB SHORING AND SUPPORTING FORMWORK SHALL NOT BE REMOVED UNTIL CONCRETE STRENGTH IS AT LEAST 70 PERCENT OF DESIGN STRENGTH, AS DETERMINED BY FIELD CURE CYLINDERS. IN ADDITION, SHORING SHALL NOT BE REMOVED SOONER THAN RECOMMENDED BY ACI 347R, SECTION 3.7.2.3 OR FOURTEEN (14) DAYS, WHICHEVER IS LONGER, UNLESS APPROVED OTHERWISE.
REINFORCING STEEL: REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, FOR DEFORMED BAR AND ASTM A185 FOR SMOOTH WELDED WIRE FABRIC (WWF), UNLESS OTHERWISE NOTED. REINFORCING STEEL TO BE WELDED SHALL CONFORM TO ASTM A706. REINFORCING STEEL SHALL BE SECURELY TIED IN PLACE WITH #16 ANNEALED IRON WIRE.
ALL DETAILING AND ACCESSORIES SHALL CONFORM TO ACI DETAILING MANUAL SP-66. PROVIDE CHAIRS, SPACERS, BOLSTERS, AND ITEMS IN CONTACT WITH FORMS WITH HOT-DIP GALVANIZED LEGS OR PLASTIC LEGS. ACCURATELY POSITION, SUPPORT, AND SECURE REINFORCEMENT AGAINST DISPLACEMENT BY FORMWORK CONSTRUCTION OR CONCRETE PLACEMENT OPERATIONS. "WET-STICKING" OF REINFORCING IS PROHIBITED.
REQUIRED CONCRETE COVER FOR REINFORCING STEEL (UNLESS NOTED OTHERWISE):
FOOTINGS 3" BOTTOM AND SIDES, 2" TOPSLABS 3/4"COLUMNS 1-1/2" TO TIES, 2" TOPBEAMS 1-1/2" TO STIRRUPSWALLS 1-1/2”
LAP SPLICE CONTINUOUS VERTICAL OR HORIZONTAL BARS IN CONCRETE MEMBERS IN ACCORDANCE WITH ACI 318, LATEST EDITION, FOR CLASS "B" TENSION LAP SPLICES. DO NOT SPLICE CONTINUOUS TOP BARS IN BEAMS AT ENDS OF CLEAR SPANS. DO NOT SPLICE CONTINUOUS BOTTOM BARS IN BEAMS IN CLEAR SPANS BETWEEN SUPPORTS. SHOW ALL SPLICES ON SHOP DRAWINGS. SPLICE LOCATIONS AND METHODS SUBJECT TO APPROVAL OF STRUCTURAL ENGINEER.
AT SLAB RE-ENTRANT CORNERS, PROVIDE (2) #5 X 4’-0” DIAGONAL BARS. AT SLAB AND WALL OPENINGS PROVIDE A MINIMUM OF (2) #5 BARS ALL FOUR SIDES AND DIAGONALLY; EXTEND THESE BARS A LAP DISTANCE OR A MINIMUM OF 24” PAST THE OPENING OR HOOK BARS IF DISCONTINUOUS.
DOWEL ALL WALLS AND COLUMNS TO FOOTINGS WITH BAR SIZE AND SPACING TO MATCH VERTICAL REINFORCING UNLESS OTHERWISE SHOWN.
SLABS ON GRADE: PREPARE SUBGRADE AS PER THE RECOMMENDATIONS OUTLINED IN THE GEOTECHNICAL REPORT. CHAIR WIRE FABRIC DURING CONCRETE PLACEMENT TO INSURE PROPER POSITION IN SLAB. USE VAPOR BARRIER UNDER ALL ENCLOSED INTERIOR SPACES, PER ARCHITECTURAL DRAWINGS.
PLACE CRACK CONTROL JOINTS AS SHOWN ON PLAN OR AT 12 FEET MAXIMUM FOR 4” SLAB, OR 15 FEET MAXIMUM FOR 6” SLAB. JOINT SPACING SHALL NOT EXCEED A 1.5 TO 1 WIDTH TO LENGTH RATIO. CONTRACTOR SHALL SUBMIT A CONTROL JOINT LAYOUT FOR ENGINEER’S AND ARCHITECT’S REVIEW PRIOR TO CONCRETE PLACEMENT. LOCATE CONTROL JOINTS AT COLUMN LINES AND RE-ENTRANT CORNERS TYPICAL. PROVIDE (1) #5 X 4’-0” DIAGONAL BARS AT SLAB RE-ENTRANT CORNERS.
FOR 4” THICK SLABS ON GRADE, PROVIDE 6X6 W1.4XW1.4 WELDED WIRE FABRIC OR 1.5 POUNDS PER CUBIC YARD OF MICRO SYNTHETIC FIBERS (FRC MONO-150 OR EQUAL), UNLESS NOTED OTHERWISE. FOR 6” THICK SLABS ON GRADE, PROVIDE 6X6 W2.9XW2.9 WELDED WIRE FABRIC PLACED 2” BELOW TOP OF SLAB OR 3 POUNDS PER CUBIC YARD OF MACRO SYNTHETIC FIBERS (FORTA FERRO OR EQUAL), UNLESS NOTED OTHERWISE.
CONCRETE ACCESSORIES: HEADED SHEAR STUDS SHALL BE NELSON HEADED ANCHORS WITH FLUXED ENDS OR APPROVED EQUAL. DEFORMED BAR ANCHORS (DBA) SHALL BE NELSON, TYPE D2L, OR APPROVED. STUDS AND DBA SHALL BE AUTOMATICALLY END WELDED WITH THE MANUFACTURER'S STANDARD EQUIPMENT IN ACCORDANCE WITH THEIR RECOMMENDATIONS. HAND WELDING NOT PERMITTED.
PERMANENTLY EXPOSED EMBEDDED PLATES AND ANGLES SHALL BE HOT-DIPPED GALVANIZED AFTER FABRICATION. ACCURATELY POSITION, SUPPORT, AND SECURE EMBEDDED ITEMS AGAINST DISPLACEMENT BY FORMWORK CONSTRUCTION OR CONCRETE PLACEMENT OPERATIONS. SECURELY ATTACH EMBEDDED ITEMS TO FORMWORK PRIOR TO START OF CONCRETE PLACEMENT. “WET-STICKING" OF EMBEDDED ITEMS IS PROHIBITED. NO LOADS OR WELDS SHALL BE PLACED ON EMBEDDED PLATES OR ANGLES FOR A MINIMUM OF 7 DAYS AFTER CASTING.
WHERE NEW CONCRETE IS PLACED AGAINST EXISTING CONCRETE, THE EXISTING CONCRETE SURFACE SHOULD BE CLEANED AND ROUGHENED TO A MINIMUM 1/4” AMPLITUDE.
HOLLOW-CORE SLABS: PRESTRESSED CONCRETE HOLLOW-CORE SLABS WITH COMPOSITE TOPPING, WHERE SHOWN ON PLANS SHALL BE DESIGNED IN ACCORDANCE WITH ACI 318. COMPOSITE HOLLOW-CORE SLABS SHALL BE DESIGNED TO SUPPORT THE SELFWEIGHT OF THE COMPOSITE SYSTEM, INDICATED SUPERIMPOSED DEAD AND LIVE LOADS, AND ADDITIONAL UNIFORM AND CONCENTRATED LOADS INDICATED ON DRAWINGS.
PROVIDE 6X6 W1.4XW1.4 WELDED WIRE FABRIC AT MID-DEPTH OF CONCRETE TOPPING OR 4 POUNDS PER CUBIC YARD OF MACRO SYNTHETIC FIBERS (FORTA FERRO OR EQUAL), UNLESS NOTED OTHERWISE.
SUBMIT COMPLETE SHOP DRAWINGS AND CALCULATIONS, SIGNED AND SEALED BY A STRUCTURAL ENGINEER LICENSED IN THE STATE OF FLORIDA, SUBSTANTIATING ALL STRENGTH AND SERVICEABILITY CRITERIA.
MECHANICAL ANCHORS: MECHANICAL ANCHORS SHALL HAVE THE ICC ES EVALUATION REPORT INDICATING CONFORMANCE WITH CURRENT APPLICABLE ICC ES ACCEPTANCE CRITERIA. MECHANICAL ANCHORS SHALL BE EXPANSION TYPE OR SCREW TYPE AS NOTED ON THE DRAWINGS.
UNLESS OTHERWISE NOTED, PROVIDE CARBON STEEL ANCHORS, ZINC PLATED IN ACCORDANCE WITH ASTM B633 OR HOT-DIPPED GALVANIZED ACCORDING TO ASTM A153. PERMANENTLY EXPOSED ANCHORS SHALL BE STAINLESS STEEL. USE 316 STAINLESS STEEL FOR MECHANICAL EQUIPMENT AND FOR ALUMINUM AND FIBERGLASS STRUCTURES AND ASSEMBLIES.
ACCEPTABLE MECHANICAL ANCHORS FOR ANCHORAGE TO CONCRETE SHALL BE AS FOLLOWS, OR AS NOTED ON THE DRAWINGS:
1. HILTI KWIK HUS EZ AND KWIK HUS EZ-I SCREW ANCHORS PER ICC ESR-3027 2. POWERS WEDGE BOLT SCREW ANCHOR PER ICC ESR-25263. SIMPSON TITEN HD SCREW ANCHOR PER ICC ESR-2713
MINIMUM EMBEDMENT FOR CONCRETE ANCHORS SHALL BE AS FOLLOWS, OR AS NOTED ON THE DRAWINGS:1. 1/2” DIAMETER – 3 3/4” EMBEDMENT2. 5/8” DIAMETER – 5” EMBEDMENT3. 3/4" DIAMETER – 5 3/4” EMBEDMENT
FOR ANCHORAGE TO SOLID GROUTED CMU PROVIDE ONE OF THE FOLLOWING ANCHORS, OR AS NOTED ON THE DRAWINGS:1. HILTI KWIK HUS EZ AND KWIK HUS EZ-I SCREW ANCHORS PER ICC ESR-3056 2. POWERS WEDGE BOLT SCREW ANCHOR PER ICC ESR-16783. SIMPSON TITEN HD SCREW ANCHOR PER ICC ESR-1056
MINIMUM EMBEDMENT FOR SOLID GROUTED CMU ANCHORS SHALL BE AS FOLLOWS, OR AS NOTED ON THE DRAWINGS: ANCHORS NOT ALLOWED WITHIN 1 1/2" OF HEAD JOINTS1. 1/2” DIAMETER – 3 3/4” EMBEDMENT2. 5/8” DIAMETER – 5” EMBEDMENT3. 3/4" DIAMETER – 5 3/4” EMBEDMENT
IDENTIFY POSITION OF REINFORCING STEEL AND OTHER EMBEDDED ITEMS PRIOR TO DRILLING HOLES FOR ANCHORS. EXERCISE CARE IN CORING OR DRILLING TO AVOID DAMAGING EXISTING REINFORCING OR EMBEDDED ITEMS. NOTIFY THE ENGINEER IF REINFORCING STEEL OR OTHER EMBEDDED ITEMS ARE ENCOUNTERED DURING DRILLING.
ADHESIVE ANCHORS: ADHESIVE ANCHORS (EPOXY STYLE) SHALL HAVE THE ICC ES EVALUATION REPORT INDICATING CONFORMANCE WITH CURRENT APPLICABLE ICC ES ACCEPTANCE CRITERIA. ADHESIVE SHALL BE MOISTURE INSENSITIVE, ALLOWING INSTALLATIONS IN DAMP OR WATER-FILLED HOLES. ADHESIVE SHALL HAVE A FULL-CURE LOAD OF 2 HOURS OR LESS AT 70°F.
ACCEPTABLE ADHESIVE IN FOUNDATIONS, SLAB ON GRADE, COLUMNS AND WALLS ARE HILTI HY-200 OR POWERS AC100+ GOLD; IN BEAMS AND ELEVATED SLABS ARE HILTI RE500 OR POWERS PE1000+.
THREADED STUDS SHALL CONFORM TO ASTM A36, UNLESS NOTED OTHERWISE. PERMANENTLY EXPOSED STUDS SHALL BE STAINLESS STEEL. NUTS AND WASHERS SHALL CONFORM TO SAME SPECIFICATION AS THE SUPPLIED ANCHOR RODS.
INSTALLATION SHALL BE IN CONFORMANCE WITH MANUFACTURER'S PRINTED LITERATURE. INSTALLATION SHALL ALSO INCLUDE BRUSHING AND CLEANING OF DRILLED HOLES WITH COMPRESSED AIR AS INSTRUCTED. INSTALLERS SHALL BE TRAINED BY THE MANUFACTURER'S REPRESENTATIVE. EMBEDMENT SHALL BE AS INDICATED ON THE STRUCTURAL DRAWINGS.
IDENTIFY POSITION OF REINFORCING STEEL AND OTHER EMBEDDED ITEMS PRIOR TO DRILLING HOLES FOR ANCHORS. EXERCISE CARE IN CORING OR DRILLING TO AVOID DAMAGING EXISTING REINFORCING OR EMBEDDED ITEMS. NOTIFY THE ENGINEER IF REINFORCING STEEL OR OTHER EMBEDDED ITEMS ARE ENCOUNTERED DURING DRILLING.
MASONRY WALLS: MASONRY UNITS SHALL MEET ASTM C90, TYPE 2. ASSEMBLIES SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF f’m= 1500 PSI. MORTAR SHALL BE TYPE "M" OR "S" AND MEET ASTM C270. GROUT SHALL BE 2000 PSI MINIMUM COMPRESSIVE STRENGTH AND MEET ASTM C476. GROUT SHALL CONSIST OF A MIXTURE OF CEMENTITIOUS MATERIALS AND AGGREGATE TO WHICH SUFFICIENT WATER HAS BEEN ADDED TO CAUSE THE MIXTURE TO FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. ALL CELLS CONTAINING VERTICAL BARS, BOND BEAMS, AND ALL CELLS BELOW
GRADE SHALL BE FILLED WITH GROUT. MAXIMUM HEIGHT OF GROUT POUR ALLOWED IS 4'-0" UNLESS CLEAN-OUT OPENING IS PROVIDED AT BOTTOM OF CELLS TO BE FILLED. LOCATE CLEAN-OUT OPENINGS IN AREAS NOT EXPOSED TO VIEW.
UNLESS NOTED OTHERWISE EIGHT INCH MASONRY WALLS SHALL BE PARTIALLY REINFORCED MASONRY WALL CONSTRUCTION WITH #5 AT 48 INCH O.C. IN GROUT FILLED CELLS. ADD (1) #5 REINFORCING BAR EACH SIDE OF OPENINGS EXCEEDING 3 FEET.
PROVIDE REINFORCING BARS AT CORNERS, INTERSECTIONS, AND EACH SIDE OF OPENINGS. PROVIDE (2) REINFORCING BARS EACH SIDE OF OPENINGS OVER 4 FEET WIDE, AND AS SHOWN ON THE PLANS. PROVIDE HOOKED DOWELS INTO FOOTINGS AND STRUCTURE ABOVE AND/OR BELOW TO PROVIDE CONTINUITY. PROVIDE 9 GAGE GALVANIZED HORIZONTAL
JOINT REINFORCING (DUR-O-WAL OR ENGINEER-APPROVED EQUAL) AT 16” O.C. REINFORCING LAPS TO BE 48 BAR DIAMETERS.
DO NOT PLACE CONDUITS, PIPES, ETC., IN CELLS WITH VERTICAL REINFORCING. DO NOT RUN CONDUITS, PIPES, ETC., HORIZONTALLY IN CMU WALLS PARALLEL TO LENGTH OF WALL. WHERE MASONRY WALLS ABUT CONCRETE COLUMNS TO BE PLACED PRIOR TO ERECTION OF MASONRY WALLS, PROVIDE DOVETAIL SLOTS BETWEEN COLUMN AND WALLS AND GROUT THE CMU CELL CONTAINING THE DOVETAIL ANCHORS. OTHERWISE, EXTEND CMU HORIZONTAL JOINT REINFORCING THROUGH CONCRETE COLUMN.
CONTROL JOINTS SHALL BE PROVIDED IN ALL CONCRETE MASONRY CONSTRUCTION AT LOCATIONS INDICATED ON THE ARCHITECTURAL DRAWINGS. HORIZONTAL WALL REINFORCING SHALL BE STOPPED EACH SIDE OF CONTROL JOINTS. SEE ARCHITECTURAL DRAWINGS FOR SEALANT REQUIREMENTS AT CONTROL JOINTS.
USE METAL LATH OR WIRE SCREEN FOR CAVITY CAPS. SHEET METAL, FELT, BUILDING PAPER, OR LIKE MATERIALS ARE PROHIBITED.
TIE BEAMS: TIE BEAMS SHALL BE CONCRETE, POURED AFTER THE BLOCK WALLS BELOW ARE IN PLACE. REINFORCING SHALL BE CONTINUOUS THROUGH TIE BEAMS WITH MINIMUM LAP SPLICES OF 48 BAR DIAMETERS AND BENT BARS AT CORNERS. USE METAL LATH, MORTAR, OR SPECIAL UNITS TO CONFINE CONCRETE TO AREA REQUIRED, IN ACCORDANCE WITH ACI 530.1, SECTION 3.5 B. SOLID METAL OR FELT CAVITY CAPS ARE PROHIBITED.
PRECAST CONCRETE LINTELS: UNLESS INDICATED OTHERWISE, ALL LINTELS TO BE "U" TYPE PRECAST CONCRETE UNITS
EQUAL TO UNITS MANUFACTURED BY CAST-CRETE CORP. AND PRESTRESSED (AND ADDITIONALLY REINFORCED AS
REQUIRED) IN ACCORDANCE WITH CAST-CRETE CORP. ''DESIGN MANUAL", LATEST EDITION, FOR THE SPAN AND LOADING CONDITION RELATIVE TO LINTEL LOCATION.
LINTEL SIZE IF NOT SHOWN ON THE PLANS SHALL BE 8F8-1B FOR OPENINGS LESS THAN 10 FEET AND 8F16-1B/1T FOR OPENINGS 10 FEET TO 20 FEET. PROVIDE 8" MINIMUM BEARING FOR LINTELS UNLESS NOTED OTHERWISE.
STRUCTURAL STEEL: STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING:W-SHAPES ASTM A992 GRADE 50.CHANNELS, PLATES AND ANGLES ASTM A36. RECTANGULAR AND SQUARE TUBES ASTM A500 GRADE B (Fy = 46KSI). ROUND HSS ASTM A500 GRADE B (Fy = 42KSI). PIPES ASTM A53 GRADE B (Fy = 35KSI).
DESIGN, FABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH THE "AISC SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS".
BOLTS SHALL CONFORM TO THE ASTM SPECIFICATION FOR A325 OR A490, HIGH STRENGTH BOLTS.
WELDING SHALL CONFORM TO THE AWS CODES FOR ARC AND GAS WELDING IN BUILDING CONSTRUCTION. WELDS SHALL BE MADE USING E70XX ELECTRODES AND SHALL BE 3/16” MINIMUM UNLESS OTHERWISE NOTED. WELDING SHALL BE BY AWS CERTIFIED WELDERS. PREQUALIFIED WELDING PROCEDURES ARE TO BE USED, UNLESS AWS QUALIFICATION IS SUBMITTED TO THE ENGINEER PRIOR TO FABRICATION.
STEEL TO RECEIVE ONE SHOP COAT AND ONE FIELD TOUCH UP COAT OF APPROVED PAINT, EXCEPT WHERE GALVANIZING IS INDICATED ON THE DRAWINGS.
ALL BOLTED CONNECTIONS SHALL CONSIST OF MINIMUM 3/4 INCH DIAMETER ASTM A325 HIGH STRENGTH BOLTS. BEAM CONNECTIONS SHALL BE DESIGNED BY THE FABRICATOR FOR THE REACTIONS SHOWN ON THE PLANS. IF NOT SHOWN, THE FABRICATOR SHALL DESIGN THE BEAM CONNECTIONS TO SUPPORT AN END REACTION OF 1/2 THE ALLOWABLE UNIFORM LOAD CAPACITY WITH A MINIMUM OF 2 BOLTS.
ANCHOR RODS: UNLESS INDICATED OTHERWISE ON THE DRAWINGS, ANCHOR RODS SHALL BE ASTM F1554 GRADE 36 AND THE SIZE SHALL BE 3/4 DIA. AND SHALL EMBED INTO THE CONCRETE FOUNDATION A DISTANCE OF 1’-0” WITH A HEAVY HEX NUT AT THE EMBEDDED END.
LIGHT-GAGE STEEL STUDS: STEEL STUDS SHALL BE C-STUDS WITH A MINIMUM YIELD OF 33,000 PSI FOR 18 AND 20 GAUGE, AND 50,000 PSI FOR 14 AND 16 GAUGE. STUDS SHALL BE OF THE SIZE, GAUGE, AND SPACING SHOWN ON THE DRAWINGS. PROVIDE BRIDGING IN CONFORMANCE WITH THE MANUFACTURER’S RECOMMENDATIONS ADEQUATE FOR DEVELOPMENT OF THE FULL MOMENT CAPACITY OF THE STUDS. FOR LOAD-BEARING STUDS, TRACK SHALL BE OVERSIZE TO PROVIDE FULL STUD BEARING. SCREWS SHALL BE ELCO DRIL-FLEX, HILTI KWIK-FLEX, OR APPROVED.
LIGHT GAUGE EXTERIOR METAL FRAMING: DESIGN AND MANUFACTURE LIGHT GAUGE METAL FRAMING, INCLUDING ALL CONNECTIONS, ANCHORAGE HARDWARE, AND FASTENERS IN ACCORDANCE WITH REQUIREMENTS OF AISI SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS (LATEST EDITION) OR THE AISI LOAD AND RESISTANCE FACTOR DESIGN SPECIFICATION FOR COLD-FORMED STEEL STRUCTURAL MEMBERS (LATEST EDITION) AND THE RECOMMENDATIONS OF THE LIGHT GAUGE METAL WALL FRAMING MANUFACTURER.
STEEL STUDS AND RUNNER TRACK MEMBERS SHALL CONFORM TO ASTM A653 GRADE C (MINIMUM YIELD POINT 40,000 PSI) WITH HOT DIPPED GALVANIZED COATING CONFORMING TO ASTM A525 (CLASS G90).
ALL FRAMING MEMBERS SHALL BE CUT SQUARELY. MEMBERS SHALL BE HELD FIRMLY IN PLACE UNTIL PROPERLY JOINED. JOINING OF MEMBERS SHALL BE MADE WITH SELF-DRILLING SCREWS OR WELDING. WIRE TYING OF FRAMING MEMBERS SHALL NOT BE PERMITTED. ATTACHMENT OF MATERIALS TO FRAMING MEMBERS SHALL BE MADE WITH SELF DRILLING SCREWS.
STUDS SHALL SIT SQUARELY IN THE TOP AND BOTTOM RUNNER TRACKS WITH FIRM ABUTMENT AGAINST TRACK WELDS. STUDS SHALL BE PLUMB AND SECURELY FASTENED TO THE FLANGES OF BOTH TOP AND BOTTOM RUNNER TRACKS.
SUBMIT COMPLETE SHOP DRAWINGS AND DESIGN CALCULATIONS, PREPARED, SIGNED, AND SEALED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF FLORIDA, SUBSTANTIATING ALL STRENGTH AND SERVICEABILITY CRITERIA.
a a
aa
32
1
3
3 3
2
2
2
5
5 5
5
4
4
a
a
3
3
3
3
2
1
2
2
2
FT
MY
ER
S, F
L 33
907
1280
0 U
NIV
ER
SIT
Y D
R. S
UIT
E 4
02
FL
LIC
EN
SE
# A
A26
0024
74
PDS A
RCHI
TECT
URE I
NC.
FX
: 855
.835
.273
3P
H: 2
39.4
37.8
090
INF
O@
PD
Sin
conl
ine.
com
TITLE:
SHEET NO.
DATE:
JOB:
REVISIONS
ALL
IDE
AS
, DE
SIG
NS
, AN
D P
LAN
S IN
DIC
AT
ED
ON
OR
RE
PR
ES
EN
TE
D B
Y T
HE
SE
DO
CU
ME
NT
S A
RE
OW
NE
D B
Y A
ND
AR
E P
RO
PE
RT
Y O
F P
DS
AR
CH
ITE
CT
RU
E IN
C.
PD
S A
RC
HIT
EC
TR
UE
INC
. HE
RE
BY
EX
PR
ES
SLY
RE
SE
RV
ES
ITS
CO
PY
RIG
HT
AN
D O
TH
ER
PR
OP
ER
TY
RIG
HT
S IN
TH
ES
E D
OC
UM
EN
TS
. TH
ES
E P
LAN
S A
ND
DR
AW
ING
S A
RE
NO
T T
O B
E R
EP
RO
DU
CE
D, C
HA
NG
ED
OR
CO
PIE
D IN
AN
Y F
OR
M O
R M
AN
NE
R W
HA
TS
OE
VE
R W
ITH
OU
T F
IRS
T O
BT
AIN
ING
TH
E E
XP
RE
SS
WR
ITT
EN
PE
RM
ISS
ION
AN
D C
ON
SE
NT
OF
PD
S A
RC
HIT
EC
TR
UE
INC
., N
OR
AR
E T
HE
Y T
O B
E A
SS
IGN
ED
TO
AN
Y P
AR
TY
WIT
HO
UT
FIR
ST
OB
TA
ININ
G S
AID
WR
ITT
EN
CO
NS
EN
T.
©P
DS
AR
CH
ITE
CT
RU
E
INC
.
18-0100
5-17-19
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
FO
R
PO
RT
CH
AR
LOT
TE
, FL
3398
3
SELECT STRUCTURAL
SELECT STRUCTURAL12573 New Brittany Blvd
Fort Myers, Florida 33907
Phone: (239) 210-5090
Certification Auth. 28357
Project No. : 19217
1Issued for Bid10-17-19
S0.02Engineer: LG Drafter:JRA
THRESHOLD
a= 6.4 ft
CORNER 5 +/-118 +/-77 +/-59PARAPET
INTERIOR 4 +/-86 +/-67 +/-59
CORNER 5 34 / -46 31 / -39 29 / -36
WALLINTERIOR 4 34 / -37 31 / -34 29 / -32
CORNER 3 15 / -95 13 / -57 12 / -41
EDGE 2 15 / -63 13 / -47 12 / -41ROOF
INTERIOR 1 15 / -38 13 / -35 12 / -34
10 SF 50 SF 100 SF
TRIBUTARY AREAALLOWABLE DESIGN WIND PRESSURES (PSF)
COMPONENT AND
CLADDING DIAGRAMS
THRESHOLD INSPECTION PLAN
GENERAL THE SPECIAL INSPECTOR OF THRESHOLD BUILDINGS OR HIS DESIGNATED REPRESENTATIVE SHALL OBSERVE THAT THE STRUCTURAL PORTION OF THE WORK ARE EXECUTED IN SUBSTANTIAL ACCORDANCE WITH THE PERMITTED CONTRACT DOCUMENTS.
THE CONTRACTOR SHALL PROVIDE THE SPECIAL INSPECTOR SAFE ACCESS TO ALL PORTIONS OF THE STRUCTURE THAT NEED INSPECTIONS. A MINIMUM OF 24 HOURS’ NOTICE SHALL BE GIVEN FOR ALL INSPECTIONS.
CONTRACTOR IS RESPONSIBLE FOR PROVIDING COMPLETE CONTRACT DOCUMENTS, INCLUDING FABRICATION/ERECTION DRAWINGS, RFI RESPONSES, AND REVISIONS. THE CONTRACTOR HAS THE SOLE RESPONSIBILITY FOR ANY DEVIATIONS FROM THE CONTRACT DOCUMENTS. THE SPECIAL INSPECTOR DOES NOT REPLACE THE QUALITY CONTROL RESPONSIBILITY OF THE CONTRACTOR.
THE SPECIAL INSPECTOR IS TO PROVIDE SERVICES ONLY WITH REGARD TO THE STRUCTURE OF THE BUILDING INCLUDING FOUNDATION, PRIMARY AND SECONDARY FRAMING SYSTEMS, AND ALL ITEMS INCLUDED IN THE INSPECTION PLAN. THIS DOES NOT INCLUDE INSPECTION OF ANY SAFETY PROVISIONS NOR DOES IT APPLY TO ELEMENTS SUCH AS GLASS, METAL, OR WOODEN RAILINGS, FIRE PROTECTION, ROOFING MECHANICAL/ELECTRICAL SYSTEMS, ARCHITECTURAL COMPONENTS, SITE WORK OR OTHER ELEMENTS NOT CONTRIBUTING TO THE CAPACITY OF THE STRUCTURAL BUILDING FRAME.
IT IS NOT THE INTENT OF THIS THRESHOLD INSPECTION PLAN FOR THE SPECIAL INSPECTOR TO BE RESPONSIBLE FOR ANY MATERIAL TESTING, WELD TESTING OR SIZING OR BOLT TESTING FOR PROJECT STRUCTURAL MEMBERS AND/OR CONNECTIONS. ALL MATERIAL TESTING AND STRUCTURAL COMPONENT TESTING WILL BE COVERED UNDER SEPARATE CONTRACT WITH APPROPRIATE PARTIES.
SINCE THE SPECIAL INSPECTOR DOES NOT CERTIFY THAT THE CONTRACT DOCUMENTS ARE, IN THEMSELVES, IN COMPLIANCE WITH THE APPLICABLE BUILDING CODES ALL CERTIFICATIONS ISSUED WILL REFER TO COMPLETED WORK BEING IN SUBSTANTIAL ACCORDANCE WITH THE CONTRACT DOCUMENTS RATHER THAN THE APPROPRIATE BUILDING CODE.
STRUCTURAL THRESHOLD INSPECTIONS INCLUDE AND ARE LIMITED TO THE ITEMS IDENTIFIED IN THIS THRESHOLD PLAN.
FOUNDATION – FOOTINGS AND SLAB ON GRADEREVIEW PLACEMENT OF REINFORCEMENT FOR COMPLIANCE WITH THE CONTRACT DOCUMENTS.
VERIFY COMPACTION REPORTS AND KEEP ON FILE.
CONCRETEVERIFY CONSTRUCTION JOINT LOCATIONS.
VERIFY OPENINGS AGAINST CONTRACT DOCUMENTS.
REVIEW EMBEDDED ITEMS.
REVIEW REINFORCEMENT DOWELING AND EXPANSION/CHEMICAL ANCHORS
VERIFY CONTRACTOR HAS SHORING INSPECTION LETTER SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA FOR FORMWORK, SHORING AND RESHORING.
REINFORCING STEELVERIFY GRADE, SIZE, QUANTITY AND SPACING OF REINFORCING BARS FOR COMPLIANCE WITH CONTRACT DOCUMENTS AS WELL AS APPROVED SHOP DRAWINGS.
VERIFY MINIMUM CLEARANCE REQUIREMENTS FROM CONCRETE SURFACES.
VERIFY THAT REINFORCING IS ADEQUATELY SUPPORTED TO RESIST DISPLACEMENT OR SHIFTING DURING POUR.
VERIFY THAT REBAR SURFACES ARE FREE OF EXCESS RUST OR OTHER COATINGS THAT MAY ADVERSELY AFFECT BONDING CAPACITY.
VERIFY REBAR SPLICE LOCATIONS AND REQUIRED LENGTH OF LAP.
VERIFY THAT DEBRIS AND FOREIGN MATERIAL HAVE BEEN REMOVED BEFORE CONCRETE IS PLACED.
STEEL STRUCTURE CHECK THE INSTALLATION OF COLUMN BASE PLATES FOR PROPER LEVELING, GROUT TYPE AND GROUT APPLICATION.
VISUALLY SPOT CHECK THAT BOLTS ARE BEING TIGHTENED PROPERLY.
VISUALLY CHECK THAT ALL CONNECTIONS ARE COMPLETED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND THE APPROVED SHOP DRAWINGS.
VERIFY STEEL BEAM SIZE AND STEEL GRADE.
REVIEW STEEL MEMBERS FOR POSSIBLE DAMAGE IN SHIPPING; CHECK WORKMANSHIP AND PIECE MARKING.
PRECAST FLOOR SYSTEMREPORT ANY NOTED VISUAL DEFECTS (INCLUDING SURFACE CRACKS) OBSERVED IN THE PRECAST MEMBER. ERECTION OF ANY REPORTED DEFECTIVE MEMBER WILL NOT BE PERMITTED.
OBTAIN DETAILED ERECTION DRAWINGS SIGNED AND SEALED BY A PROFESSIONAL ENGINEER IN THE STATE OF FLORIDA AND APPROVED BY THE ENGINEER FOR PRECAST PRESTRESSED CONCRETE.
VERIFY THAT PRECAST PRESTRESSED CONCRETE MEMBERS ARE ERECTED IN CONFORMANCE WITH APPROVED DRAWINGS AND DETAILS.
REINFORCED CONCRETE MASONRY (CMU)OBSERVE MORTAR MIX AND PLACEMENT. VERIFY THAT GROUT INSPECTION AND TESTING IS IN ACCORDANCE WITH CONTRACT DOCUMENTS.
VERIFY PLACEMENT OF JOINT REINFORCING AND WALL VERTICAL STEEL WHERE SPECIFIED.
VERIFY THAT CONTROL JOINTS ARE PLACED IN WALLS AS SPECIFIED.
VERIFY PROPER CONNECTION TO SUPPORT STRUCTURE.
VERIFY PROPER PLACEMENT OF CMU LINTELS, DOOR AND WINDOW JAMBS.
NOTIFY THE ENGINEER OF RECORD WHEN PLACEMENT OF CONDUIT OR PIPING INTERFERES WITH CELL GROUTING AND VERTICAL REINFORCING STEEL.
VERIFY THAT PLACEMENT AND CONSOLIDATION OF GROUT IS IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS.
FOUNDATION PLAN NOTES:
1. SEE ARCHITECTURAL DRAWINGS FOR SLOPES, STEPS, DRAIN LOCATIONS, AND VAPOR BARRIER REQUIREMENTS FOR FLOOR SLABS.
2. VERIFY/COORDINATE EDGE OF SLAB DETAILS AT EXTERIOR DOORS WITH ARCHITECTURAL DRAWINGS.
3. VERIFY/COORDINATE SILL HEIGHTS AND DETAILS OF WALL OPENINGS WITH ARCHITECTURAL DRAWINGS.
4. SEE GEOTECHNICAL RECOMMENDATIONS FOR SUBGRADE COMPACTION AND DRAINAGE REQUIREMENTS.
5. VERIFY/COORDINATE LOCATION OF UNDERGROUND PIPING WITH FOUNDATIONS.
6. DO NOT SCALE DRAWINGS. VERIFY/COORDINATE ALL DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS BEFORE COMMENCING CONSTRUCTION. NOTIFY STRUCTURAL ENGINEER AND ARCHITECT OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK.
7. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS PRIOR TO COMMENCING CONSTRUCTION. NOTIFY THE ENGINEER OF RECORD OF ANY DISCREPANCIES.
8. 'FX' INDICATES FOOTING TYPE, SEE SCHEDULE THIS SHEET.
9. X’-X” INDICATES TOP OF FOOTING ELEVATION, -2’-0” UNO.
10. INDICATES 8” CMU WALL WITH #5 AT 40” OC MAX AND AT CORNERS, INTERSECTIONS AND BOTH SIDES OF OPENINGS, UNO.
11. INDICATES CONCRETE COLUMN TYPE. SEE SCHEDULE.
12. INDICATES STEP IN FOOTING. COORDINATE LOCATION WITH MEP DRAWINGS.
C#
C3
HSS8X8X
1/2
HSS12X12
X5/8F130
F90
F80
F130
F66W
F40W
F20W
F20W
F20W
F20W
F20W
F40W
F40W
F40W
F46W
F40W
F46W
F20W
F20W
F20W
F20W
F20W
F20W
F20WF
20W
F20W
F20W
F56U
F20W
F20W
F20W F20W F20W
F40W
18' - 4" 193' - 7"
3' - 9" 53' - 2" 31' - 0" 105' - 8"
22' - 0" 3' - 6" 13' - 0" 14' - 6"
67' -
8"
1' -
0"
30' -
8"
5' -
4"
30' -
8"
10' -
1"
19' - 11"
6' - 0"
98' - 6" 25' - 4" 40' - 6"
10' - 11" 8' - 3"
17' -
4"
14' -
0"
58' - 0" 9" 5' - 0" 30' - 2" 4' - 7" 4' - 7" 35' - 11"
30' - 10" 22' - 4" 5' - 2" 25' - 10"
12' -
2"
6' -
0"
12' -
10"
14' -
0"
9' -
2"
34' -
8"
5' - 0" 26' - 8" 66' - 10"
6' - 11"
2' - 0"
2' -
6"
27' -
6"
20' -
0"
26' -
5"
21' -
0"
5' -
0"
76' -
5"
26' -
0"
36' -
8"
9' -
0"
4' -
5"
5' -
8"
2' -
0"
7' -
0"
11' -
8"
5' - 0" 12' - 11" 13' - 4" 4' - 1" 8' - 0" 12' - 8" 12' - 8" 8' - 0" 5' - 0"
8' - 10"
5 3
/4"
4' -
0"
6 1
/4"
F20W
F20W F20W
F20W F30U
F30U F30U
F30U F30U
F30U F20W
F20W
F20W
F20W
F20W
F20W
F20W
F20W
F20W
4" CONCRETE SLAB ON GRADEW/ 6x6 W1.4xW1.4 WWF
TYPICAL
F36U F46U F36U
F56UF56U
F66U F66U
F56U
T/FOOTING
-5' - 0"
SUMP PITTYPICAL
1
S5.01
TYP
12
S5.01
12
S5.01
4
S5.01
TYP
8
S5.01
TYP
4
S5.01
TYP
4
S5.01
TYP
3
S5.01
TYP
3
S5.01
TYP
6
S5.01
TYP
8
S5.01
TYP
8
S5.01
TYP
8' -
0"
6' -
0"
22' -
10"
F130170
C4
F66W
C4
F40W
26' - 4" 26' - 4"
PRE ENGINEERED CANOPYCOLUMN, BY OTHERS(TYPICAL 3 PLCS)
PRE ENGINEERED CANOPYCOLUMN, BY OTHERS(TYPICAL 6 PLCS)
PRE ENGINEERED CANOPYCOLUMN, BY OTHERS(TYPICAL 6 PLCS)
T/SLAB T/SLAB 0' - 0"
4' - 0"
C2
C1
C1
F56U
C1
5
S5.01
F40W
11
S5.01
6
S5.01
TYP
C1
C1
3' -
0"
F20W
9
S5.01
TYP
#5V IN 2 FILLEDCELLS AT ENDOF WALL
7' -
0"
8' -
4 1
/4"
10
S5.01
81' - 8"
F20W
6' -
1"
2' -
0"
1
2
3
A B C D E
7' - 8"
191' - 2"
4
5
C.7 D.5 E.5
18' -
5"
D.1
1
1
1
1
1
11
PAD FOUNDATION SCHEDULE
MARK LENGTH WIDTH THICKNESS REINFORCEMENT COMMENTS
F30U 3' - 0" 3' - 0" 1' - 4" (4) #5 EW TOP & BOT -
F36U 3' - 6" 3' - 6" 2' - 0" (4) #5 EW TOP & BOT -
F46U 4' - 6" 4' - 6" 2' - 0" (5) #5 EW TOP & BOT -
F56U 5' - 6" 5' - 6" 2' - 0" (6) #5 EW TOP & BOT -
F66U 6' - 6" 6' - 6" 2' - 0" (7) #5 EW TOP & BOT -
F80 8' - 0" 8' - 0" 1' - 8" (9) #6 EW BOT -
F90 9' - 0" 9' - 0" 2' - 0" (10) #6 EW BOT -
F130 13' - 0" 13' - 0" 2' - 4" (14) #7 EW BOT -
F130170 17' - 0" 13' - 0" 2' - 4" (14) #7 LW, (18) #7 SW -
WALL FOUNDATION SCHEDULE
MARK WIDTH THICKNESS REINFORCEMENT COMMENTS
F20W 2' - 0" 1' - 0" (3) #5 CONT. BOT -
F40W 4' - 0" 1' - 0" (5) #5 CONT. & #4 @ 12" OC TRANSVERSE BOT -
F46W 4' - 6" 1' - 0" (5) #5 CONT. & #4 @ 12" OC TRANSVERSE BOT -
F66W 6' - 6" 1' - 0" (7) #5 CONT. & #4 @ 12" OC TRANSVERSE BOT -
CONCRETE COLUMN SCHEDULE
MARK WIDTH SS_HEIGHT REINFORCING COMMENTS
C1 0' - 8" 1' - 4" (4) #6 VERT & #3 @ 8" OC -
C2 0' - 8" 2' - 0" (6) #6 VERT & #3 @ 8" OC -
C3 0' - 8" 2' - 4" (8) #6 VERT & #3 @ 8" OC -
C4 1' - 8" 1' - 8" (12) #6 VERT & #3 @ 12" OC -
STEEL COLUMN SCHEDULE
SIZE BASE PLATE ANCHOR RODS
HSS6X6X1/4 1"x14"x1'-2" (4) 3/4" DIA THRU BOLTS
HSS8X8X1/2 1"x14"x1'-2" (4) 3/4" DIA (12" EMBED)
HSS12X12X5/8 1"x18"x1'-6" (4) 3/4" DIA (12" EMBED)
FT
MY
ER
S, F
L 33
907
1280
0 U
NIV
ER
SIT
Y D
R. S
UIT
E 4
02
FL
LIC
EN
SE
# A
A26
0024
74
PDS A
RCHI
TECT
URE I
NC.
FX
: 855
.835
.273
3P
H: 2
39.4
37.8
090
INF
O@
PD
Sin
conl
ine.
com
TITLE:
SHEET NO.
DATE:
JOB:
REVISIONS
ALL
IDE
AS
, DE
SIG
NS
, AN
D P
LAN
S IN
DIC
AT
ED
ON
OR
RE
PR
ES
EN
TE
D B
Y T
HE
SE
DO
CU
ME
NT
S A
RE
OW
NE
D B
Y A
ND
AR
E P
RO
PE
RT
Y O
F P
DS
AR
CH
ITE
CT
RU
E IN
C.
PD
S A
RC
HIT
EC
TR
UE
INC
. HE
RE
BY
EX
PR
ES
SLY
RE
SE
RV
ES
ITS
CO
PY
RIG
HT
AN
D O
TH
ER
PR
OP
ER
TY
RIG
HT
S IN
TH
ES
E D
OC
UM
EN
TS
. TH
ES
E P
LAN
S A
ND
DR
AW
ING
S A
RE
NO
T T
O B
E R
EP
RO
DU
CE
D, C
HA
NG
ED
OR
CO
PIE
D IN
AN
Y F
OR
M O
R M
AN
NE
R W
HA
TS
OE
VE
R W
ITH
OU
T F
IRS
T O
BT
AIN
ING
TH
E E
XP
RE
SS
WR
ITT
EN
PE
RM
ISS
ION
AN
D C
ON
SE
NT
OF
PD
S A
RC
HIT
EC
TR
UE
INC
., N
OR
AR
E T
HE
Y T
O B
E A
SS
IGN
ED
TO
AN
Y P
AR
TY
WIT
HO
UT
FIR
ST
OB
TA
ININ
G S
AID
WR
ITT
EN
CO
NS
EN
T.
©P
DS
AR
CH
ITE
CT
RU
E
INC
.
18-0100
5-17-19
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
FO
R
PO
RT
CH
AR
LOT
TE
, FL
3398
3
SELECT STRUCTURAL
SELECT STRUCTURAL12573 New Brittany Blvd
Fort Myers, Florida 33907
Phone: (239) 210-5090
Certification Auth. 28357
Project No. : 19217
1Issued for Bid10-17-19
S1.01Engineer: LG Drafter:JRA
FOUNDATION
SCALE: 1/8" = 1'-0"
FOUNDATION
1
1
1
B4 T13' - 0"
C3
BB
1B
B1
B7 T13' - 0"
BB1
BB
1
BB
1
BB1BB1
BB
1
BB1
BB1
BB1
BB
1
BB
1
B7 T13' - 0"
BB
1
BB1
BB
1
BB
1
BB
1
BB
1
BB1
BB1
BB
1
BB1
BB
1
BB
1
BB
1BB1
BB
1
BB
1
BB
1
BB1
BB
1
BB1
BB
1
BB1
P1
P1
P1
P1
P1
P1
P1
P1
1
S5.02
TYP
2
S5.02
TYP
9
S5.00
TYP
1
S5.02
TYP
4
S5.02
TYP
5
S5.02
T12' -
2"
B2
P1
4
S5.02
TYP
HSS6X4X3/8
1
S5.02
TYP
B6 (
2 S
PA
N)
T13
' -0"
BB
1
B3 (
3 S
PA
N)
T12
' -2"
B5 (
2 S
PA
N)
T16
' -8"
9
S5.03
3
S5.02
TYP
2
S5.02
TYP
19' -
0"
1' -
8"
5' -
8"
48' -
1"
3' -
0"
1' - 0"30' - 10" 53' - 4"
85' - 2" 105' - 8"
6' -
0"
1' -
0"
11 3
/4"14
S5.02
14
S5.022
S5.02
TYP
77' -
5"
66' -
8"
190' - 10"
SIM SIM
SIM
PRE ENGINEEREDCANOPY BY OTHERS
PRE ENGINEEREDCANOPY BY OTHERS
PRE ENGINEEREDCANOPY BY OTHERS
C1
C1
C1
C2
C4
C4
B3 T12' - 2"
8
S5.02
6
S5.03
TYP
10
S5.02
TYP
T/SLAB 13' - 0"
15
S5.02
B3 T12' - 2"
BB1
BB
1
BB1
BB
1 T
11' -
10" BB1 T11' - 10"
BB
1
BB1
BB
1
BB
1
BB1B
B1
BB1 T11' - 10"B
B1
C1
C1
13
S5.02
8F
24-1
B/2
T
B
3 T
10
' -8"
B2 T12' - 2"
9
S5.02
B3 T
12
' -2"
13
S5.02
9
S5.02
1
2
3
A B C D E
4
5
C.7 D.5 E.5
191' - 2"
40' - 6"19' - 2" 106' - 2" 25' - 4"
6' -
1"
3' -
9"
12
S5.01
D.1
1
1
FRAMING PLAN NOTES:
1. SEE ARCHITECTURAL DRAWINGS FOR SLOPES, DROPS, AND DRAIN LOCATION IN FLOOR SLABS.
2. P1 INDICATES SPAN DIRECTION OF 8" HOLLOW CORE PLANK WITH 2" MINIMUM CONCRETE TOPPING W/ 6X6 W1.4XW1.4 WWF (10” TOTAL THICKNESS).
3. TX’-X” INDICATES TOP OF BEAM ELEVATION.
4. INDICATES 8” CMU WALL WITH #5 AT 40” OC MAX AND AT CORNERS, INTERSECTIONS AND BOTH SIDES OF OPENINGS, UNO.
5. INDICATES CONCRETE COLUMN ABOVE AND BELOW FLOOR LEVEL.
6. INDICATES CONCRETE COLUMN BELOW FLOOR LEVEL.
7. INDICATES CONCRETE COLUMN ABOVE FLOOR LEVEL.
C#
C#
C#
CONCRETE BEAM SCHEDULE
MARK WIDTH DEPTH
REINFORCEMENT
COMMENTSTOP MID BOT STIRRUPS
B1 8" 1' - 0" (2) #7 - (2) #7 #3 @4" OC -
B2 8" 1' - 4" (2) #6 - (2) #6 #3 @ 6" OC -
B3 8" 1' - 8" (4) #7 (2) #5 (4) #7 #3 @ 8" OC TOP & BOT STEEL IN 3 LAYERS
B4 8" 2' - 6" (4) #8 (2) #6 (4) #8 #4 @ 12" OC TOP & BOT STEEL IN 2 LAYERS
B5 8" 4' - 8" (6) #8 (4) #6 (6) #8 #4 @ 4" OC TOP & BOT STEEL IN 3 LAYERS
B6 1' - 8" 2' - 6" (10) #8 (2) #6 (10) #8 (2) #4 @ 6" OC TOP & BOT STEEL IN 2 LAYERS
B7 1' - 8" 3' - 0" (10) #7 (4) #5 (10) #7 #4 @ 4" OC TOP & BOT STEEL IN 2 LAYERS
BB1 8" 0' - 8" (2) #5 - - - SINGLE COURSE BOND BEAMS
BB2 8" 1' - 4" (2) #5 - (2) #5 - DOUBLE COURSE BOND BEAMS
FT
MY
ER
S, F
L 33
907
1280
0 U
NIV
ER
SIT
Y D
R. S
UIT
E 4
02
FL
LIC
EN
SE
# A
A26
0024
74
PDS A
RCHI
TECT
URE I
NC.
FX
: 855
.835
.273
3P
H: 2
39.4
37.8
090
INF
O@
PD
Sin
conl
ine.
com
TITLE:
SHEET NO.
DATE:
JOB:
REVISIONS
ALL
IDE
AS
, DE
SIG
NS
, AN
D P
LAN
S IN
DIC
AT
ED
ON
OR
RE
PR
ES
EN
TE
D B
Y T
HE
SE
DO
CU
ME
NT
S A
RE
OW
NE
D B
Y A
ND
AR
E P
RO
PE
RT
Y O
F P
DS
AR
CH
ITE
CT
RU
E IN
C.
PD
S A
RC
HIT
EC
TR
UE
INC
. HE
RE
BY
EX
PR
ES
SLY
RE
SE
RV
ES
ITS
CO
PY
RIG
HT
AN
D O
TH
ER
PR
OP
ER
TY
RIG
HT
S IN
TH
ES
E D
OC
UM
EN
TS
. TH
ES
E P
LAN
S A
ND
DR
AW
ING
S A
RE
NO
T T
O B
E R
EP
RO
DU
CE
D, C
HA
NG
ED
OR
CO
PIE
D IN
AN
Y F
OR
M O
R M
AN
NE
R W
HA
TS
OE
VE
R W
ITH
OU
T F
IRS
T O
BT
AIN
ING
TH
E E
XP
RE
SS
WR
ITT
EN
PE
RM
ISS
ION
AN
D C
ON
SE
NT
OF
PD
S A
RC
HIT
EC
TR
UE
INC
., N
OR
AR
E T
HE
Y T
O B
E A
SS
IGN
ED
TO
AN
Y P
AR
TY
WIT
HO
UT
FIR
ST
OB
TA
ININ
G S
AID
WR
ITT
EN
CO
NS
EN
T.
©P
DS
AR
CH
ITE
CT
RU
E
INC
.
18-0100
5-17-19
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
FO
R
PO
RT
CH
AR
LOT
TE
, FL
3398
3
SELECT STRUCTURAL
SELECT STRUCTURAL12573 New Brittany Blvd
Fort Myers, Florida 33907
Phone: (239) 210-5090
Certification Auth. 28357
Project No. : 19217
1Issued for Bid10-17-19
S1.02Engineer: LG Drafter:JRA
SECOND FLOOR
SCALE: 1/8" = 1'-0"
SECOND FLOOR FRAMING PLAN
BB
1
BB1BB1
BB1BB1
BB
1
BB1
BB1
BB1
BB
1
BB1
BB
1
BB1
BB
1
BB1BB1
BB
1
BB1
BB
1
BB
1
BB
1
BB
1
BB1
BB
1
BB1
BB
1
BB1
BB
1
BB1
P1
P1
P1
HSS6X4X3/8
P1
P1
P1
P1
P1
B1 T
23
' -0"
B1 T
23
' -0"
B1 T
23
' -0"
P1
T/SLAB
23'-2" 3RD FLOOR
33'-4" 4TH FLOOR
1
S5.02
TYP
BB
1 BB
1
BB
1
BB
1 T
22
' -4"
BB
1B
B1
2
S5.02
TYP
3
S5.02
TYP
4
S5.02
TYP
2
S5.02
TYP
3
S5.02
TYP
2
S5.02
TYP
1
S5.02
TYP
9
S5.00
TYP
1
S5.02
TYP
P1
B2 T
22
' -4"
B1 T
33
' -2"
B1 T
33
' -2"
B1 T
33
' -2"
BB
1 T
32
' -6"
B2 T
32
' -6"
C1
12
S5.03
1
2
3
B C D EC.7 D.5 E.5D.1
11
S5.03
11
S5.03
1
1
1
1
FRAMING PLAN NOTES:
1. SEE ARCHITECTURAL DRAWINGS FOR SLOPES, DROPS, AND DRAIN LOCATION IN FLOOR SLABS.
2. P1 INDICATES SPAN DIRECTION OF 8" HOLLOW CORE PLANK WITH 2" MINIMUM CONCRETE TOPPING W/ 6X6 W1.4XW1.4 WWF (10” TOTAL THICKNESS).
3. TX’-X” INDICATES TOP OF BEAM ELEVATION.
4. INDICATES 8” CMU WALL WITH #5 AT 40” OC MAX AND AT CORNERS, INTERSECTIONS AND BOTH SIDES OF OPENINGS, UNO.
5. INDICATES CONCRETE COLUMN ABOVE AND BELOW FLOOR LEVEL.
6. INDICATES CONCRETE COLUMN BELOW FLOOR LEVEL.
7. INDICATES CONCRETE COLUMN ABOVE FLOOR LEVEL.
C#
C#
C#
FT
MY
ER
S, F
L 33
907
1280
0 U
NIV
ER
SIT
Y D
R. S
UIT
E 4
02
FL
LIC
EN
SE
# A
A26
0024
74
PDS A
RCHI
TECT
URE I
NC.
FX
: 855
.835
.273
3P
H: 2
39.4
37.8
090
INF
O@
PD
Sin
conl
ine.
com
TITLE:
SHEET NO.
DATE:
JOB:
REVISIONS
ALL
IDE
AS
, DE
SIG
NS
, AN
D P
LAN
S IN
DIC
AT
ED
ON
OR
RE
PR
ES
EN
TE
D B
Y T
HE
SE
DO
CU
ME
NT
S A
RE
OW
NE
D B
Y A
ND
AR
E P
RO
PE
RT
Y O
F P
DS
AR
CH
ITE
CT
RU
E IN
C.
PD
S A
RC
HIT
EC
TR
UE
INC
. HE
RE
BY
EX
PR
ES
SLY
RE
SE
RV
ES
ITS
CO
PY
RIG
HT
AN
D O
TH
ER
PR
OP
ER
TY
RIG
HT
S IN
TH
ES
E D
OC
UM
EN
TS
. TH
ES
E P
LAN
S A
ND
DR
AW
ING
S A
RE
NO
T T
O B
E R
EP
RO
DU
CE
D, C
HA
NG
ED
OR
CO
PIE
D IN
AN
Y F
OR
M O
R M
AN
NE
R W
HA
TS
OE
VE
R W
ITH
OU
T F
IRS
T O
BT
AIN
ING
TH
E E
XP
RE
SS
WR
ITT
EN
PE
RM
ISS
ION
AN
D C
ON
SE
NT
OF
PD
S A
RC
HIT
EC
TR
UE
INC
., N
OR
AR
E T
HE
Y T
O B
E A
SS
IGN
ED
TO
AN
Y P
AR
TY
WIT
HO
UT
FIR
ST
OB
TA
ININ
G S
AID
WR
ITT
EN
CO
NS
EN
T.
©P
DS
AR
CH
ITE
CT
RU
E
INC
.
18-0100
5-17-19
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
FO
R
PO
RT
CH
AR
LOT
TE
, FL
3398
3
SELECT STRUCTURAL
SELECT STRUCTURAL12573 New Brittany Blvd
Fort Myers, Florida 33907
Phone: (239) 210-5090
Certification Auth. 28357
Project No. : 19217
1Issued for Bid10-17-19
S1.03Engineer: LG Drafter:JRA
3RD & 4TH FLOOR
SCALE: 1/8" = 1'-0"
THIRD AND FOURTH FLOOR FRAMING PLAN
CONCRETE BEAM SCHEDULE
MARK WIDTH DEPTH
REINFORCEMENT
COMMENTSTOP MID BOT STIRRUPS
B1 8" 1' - 0" (2) #7 - (2) #7 #3 @4" OC -
B2 8" 1' - 4" (2) #6 - (2) #6 #3 @ 6" OC -
B3 8" 1' - 8" (4) #7 (2) #5 (4) #7 #3 @ 8" OC TOP & BOT STEEL IN 3 LAYERS
B4 8" 2' - 6" (4) #8 (2) #6 (4) #8 #4 @ 12" OC TOP & BOT STEEL IN 2 LAYERS
B5 8" 4' - 8" (6) #8 (4) #6 (6) #8 #4 @ 4" OC TOP & BOT STEEL IN 3 LAYERS
B6 1' - 8" 2' - 6" (10) #8 (2) #6 (10) #8 (2) #4 @ 6" OC TOP & BOT STEEL IN 2 LAYERS
B7 1' - 8" 3' - 0" (10) #7 (4) #5 (10) #7 #4 @ 4" OC TOP & BOT STEEL IN 2 LAYERS
BB1 8" 0' - 8" (2) #5 - - - SINGLE COURSE BOND BEAMS
BB2 8" 1' - 4" (2) #5 - (2) #5 - DOUBLE COURSE BOND BEAMS
RTU-24000#
RTU-14000#
6
S5.02HSS6X6X
1/4
POST U
P TYPIC
AL
HSS6X6X
1/4
POST U
P TYPIC
AL
9' - 0 5/8" 9' - 0 5/8" 9' - 0 5/8" 12' - 9 3/8"
21' -
3"
6' -
7"
6' -
7"
6' -
7"
7
S5.03
7
S5.03
8
S5.03
6
S5.028
S5.02
P1
P1
P1 P1
P1
P1
P1
P1
BB
1B
B1
B1 T
43
' -4"
BB
1B
1 T
43
' -4"
BB
1
BB
1
BB1
BB1
B1 T
43
' -4"
BB
1
BB2 T42' - 8" BB
1
BB1
BB
1 BB2 T42' - 8"
BB1 T42' - 8"
BB
1 T
42
' -8"
BB1 T42' - 8"
BB
1 T
42
' -8"
BB1 T42' - 8"
BB1 T42' - 8"
BB
1
BB1 T42' - 8"
BB
1 T
42
' -8"
BB
1 T
42
' -8"
BB1 BB1
BB1
BB
1
BB1
6
S5.02
21' - 8 5/8" 9' - 10 1/4" 9' - 10 1/4"
11' -
3"
9' -
0 5
/8"
9' -
0 5
/8"
9' -
0 5
/8"
7
S5.03
B6 T
42
' -8"
BB2 T42' - 8"
BB2 T42' - 8"
BB
2 T
42
' -8"
T/WALL
48' - 2"
T/WALL
48' - 2"
T/WALL
46' - 2"
T/WALL
48' - 2"
T/WALL
48' - 2"
T/WALL
48' - 2"
T/WALL
48' - 2"
T/WALL
48' - 2"
T/WALL
46' - 2"
T/WALL
48' - 2"
T/WALL
48' - 2"
T/SLAB 43' - 6"
T/WALL
48' - 2"
T/WALL
48' - 2"
T/WALL
51' - 0"
T/WALL
51' - 0"
T/WALL
51' - 0"
T/WALL
48' - 2"
T/WALL
54' - 4"
T/WALL
54' - 4"
T/WALL
54' - 4"
B2 T
42
' -8"
W12X19
W8X
10
W8X
10
HOIST BEAMCOORD W/ELEVATOR MANUF
8
S5.03
5
S5.03
TYP
4
S5.03
TYP4
S5.03
TYP
3
S5.03
4
S5.03
TYP
3
S5.03
8
S5.03
10
S5.03
12
S5.03
T/WALL
51' - 0"
LIGHT FEATUREWITH LT GAUGEMETAL FRAMINGBY OTHERS
1
S5.03
10
S5.03
(4) CU200# EACH
BB2 T42' - 8"
w=350 PLF(WORKING LOAD)
w=350 PLF(WORKING LOAD)
7
S5.02
w=350 PLF(WORKING LOAD)
w=350 PLF(WORKING LOAD)
w=
35
0 P
LF
(WO
RK
ING
LO
AD
)
EF
EF
EF EF EF EF
EF
EF
EF
EFEFEF
EF
5
S5.03
TYP
1' - 0"
1' -
0"
1' - 0"
68
' -
8"
192' - 2"
77
' -
5"
85' - 2" 12' - 6" 94' - 2"
191' - 10"
T/SLAB 48' - 4"
BB1 T47' - 6"
BB
1 T
47
' -6"
BB1 T47' - 6"
BB1 T47' - 6"
BB
1 T
47
' -6"
BB
1 T
47
' -6"
1
2
3
B C D EC.7 D.5 E.5
19' - 2" 106' - 2" 25' - 4" 41' - 6"
2' -
8 7
/8"
6' -
1"
D.1
2
S5.03
11
S5.03
11
S5.03
EF
HSS6X6X1/4 T51' - 6"HSS6X6X1/4 T48' - 6"TYP
HSS4X4X1/4 BRACE-TYP
HSS6X6X1/4 T51' - 6"HSS6X6X1/4 T48' - 6"TYP
HSS4X4X1/4 BRACE-TYP
CU200#
(3) CU200# EACH
ROOF HATCHPER ARCH
(4) CU200# EACH
T/WALL
54' - 4"
8" LT GAUGEMETAL STUDFRAMINGM=2.2K-FT/FT(WALL TO HOLLOWCORE)
W=200PLFWORKING LOAD
ROOF FRAMING PLAN NOTES:
1. SEE ARCHITECTURAL DRAWINGS FOR SLOPES, DROPS, AND DRAIN LOCATION IN FLOOR SLABS.
2. P1 INDICATES SPAN DIRECTION OF 8" HOLLOW CORE PLANK WITH 2" MINIMUM CONCRETE TOPPING W/ 6X6 W1.4XW1.4 WWF (10” TOTAL THICKNESS).
3. TX’-X” INDICATES TOP OF BEAM ELEVATION.
4. INDICATES 8” LT GAUGE METAL STUD WALL.
FT
MY
ER
S, F
L 33
907
1280
0 U
NIV
ER
SIT
Y D
R. S
UIT
E 4
02
FL
LIC
EN
SE
# A
A26
0024
74
PDS A
RCHI
TECT
URE I
NC.
FX
: 855
.835
.273
3P
H: 2
39.4
37.8
090
INF
O@
PD
Sin
conl
ine.
com
TITLE:
SHEET NO.
DATE:
JOB:
REVISIONS
ALL
IDE
AS
, DE
SIG
NS
, AN
D P
LAN
S IN
DIC
AT
ED
ON
OR
RE
PR
ES
EN
TE
D B
Y T
HE
SE
DO
CU
ME
NT
S A
RE
OW
NE
D B
Y A
ND
AR
E P
RO
PE
RT
Y O
F P
DS
AR
CH
ITE
CT
RU
E IN
C.
PD
S A
RC
HIT
EC
TR
UE
INC
. HE
RE
BY
EX
PR
ES
SLY
RE
SE
RV
ES
ITS
CO
PY
RIG
HT
AN
D O
TH
ER
PR
OP
ER
TY
RIG
HT
S IN
TH
ES
E D
OC
UM
EN
TS
. TH
ES
E P
LAN
S A
ND
DR
AW
ING
S A
RE
NO
T T
O B
E R
EP
RO
DU
CE
D, C
HA
NG
ED
OR
CO
PIE
D IN
AN
Y F
OR
M O
R M
AN
NE
R W
HA
TS
OE
VE
R W
ITH
OU
T F
IRS
T O
BT
AIN
ING
TH
E E
XP
RE
SS
WR
ITT
EN
PE
RM
ISS
ION
AN
D C
ON
SE
NT
OF
PD
S A
RC
HIT
EC
TR
UE
INC
., N
OR
AR
E T
HE
Y T
O B
E A
SS
IGN
ED
TO
AN
Y P
AR
TY
WIT
HO
UT
FIR
ST
OB
TA
ININ
G S
AID
WR
ITT
EN
CO
NS
EN
T.
©P
DS
AR
CH
ITE
CT
RU
E
INC
.
18-0100
5-17-19
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
FO
R
PO
RT
CH
AR
LOT
TE
, FL
3398
3
SELECT STRUCTURAL
SELECT STRUCTURAL12573 New Brittany Blvd
Fort Myers, Florida 33907
Phone: (239) 210-5090
Certification Auth. 28357
Project No. : 19217
1Issued for Bid10-17-19
S1.04Engineer: LG Drafter:JRA
ROOF PLAN
SCALE: 1/8" = 1'-0"
ROOF FRAMING PLAN
CONCRETE BEAM SCHEDULE
MARK WIDTH DEPTH
REINFORCEMENT
COMMENTSTOP MID BOT STIRRUPS
B1 8" 1' - 0" (2) #7 - (2) #7 #3 @4" OC -
B2 8" 1' - 4" (2) #6 - (2) #6 #3 @ 6" OC -
B3 8" 1' - 8" (4) #7 (2) #5 (4) #7 #3 @ 8" OC TOP & BOT STEEL IN 3 LAYERS
B4 8" 2' - 6" (4) #8 (2) #6 (4) #8 #4 @ 12" OC TOP & BOT STEEL IN 2 LAYERS
B5 8" 4' - 8" (6) #8 (4) #6 (6) #8 #4 @ 4" OC TOP & BOT STEEL IN 3 LAYERS
B6 1' - 8" 2' - 6" (10) #8 (2) #6 (10) #8 (2) #4 @ 6" OC TOP & BOT STEEL IN 2 LAYERS
B7 1' - 8" 3' - 0" (10) #7 (4) #5 (10) #7 #4 @ 4" OC TOP & BOT STEEL IN 2 LAYERS
BB1 8" 0' - 8" (2) #5 - - - SINGLE COURSE BOND BEAMS
BB2 8" 1' - 4" (2) #5 - (2) #5 - DOUBLE COURSE BOND BEAMS
1
1
KEYED JOINT (AT SLAB MID-DEPTH)PAINT W/CURING COMPOUND ASBOND BREAK BEFORE ADJACENTSLAB IS PLACED
SLABREINF
SAW CUT JOINTSAME DAY AS POUR
SLABREINF
NOTE:CONTROL JOINTS TO BE SPACED PER ACI RECOMMENDATIONS AND 36x SLAB DEPTH OC MAX
CONSTRUCTION JOINT
CONTROL JOINT
IV:3HCOMPACTEDSTRUCTURAL FILL
VAPOR BARRIERPER ARCH
COMPACTED STRUCTURAL FILL
DE
PT
H1
/4"
SL
AB
VAPOR BARRIERPER ARCH
SLA
BD
EP
TH
MATCH BOTTOMREINFORCING
MATCH FOOTINGREINFORCING
11
4' - 0" MIN
1' - 6"
MA
X
2' -
0"
CONCRETE FOOTING
EXTEND ALL REINFORCING TO FAR FACE
CORNERREINFORCING(1) #5 2'-6"
2'-6"
SEEP
LAN
PRECASTCONCRETELINTEL
OPENING
MATCH TYPICAL WALL REINFORCING ABOVE AND BELOW OPENINGS
GROUT SILL SOLID, AT OPENINGS4'-0" AND WIDER PROVIDE (1) #5
REINFORCEDMASONRY WALL
VERTICAL REINFORCINGAT EACH OPENING - SEEPLAN FOR ADDITIONALREINFORCING REQUIREMENTS
CONCRETE TIE BEAM
MASONRY COURSESAS REQ'D
OPENING WIDTH LINTEL SIZE
W < 6' 8F8-1B
6' < W < 10' 8F16-1B/2T
10' < W < 14' 8F24-1B/2T
NO
MIN
AL H
EIG
HT
(1) #5 TOP
GROUT SOLID
(1) #5 BOT
PRECAST LINTEL
8F16-1B/1T
NOMINAL WIDTH
F= FILLED WITHGROUT/ U=UNFILLED
NOMINAL HEIGHT
QUANTITY OF #5 REBAR ATBOTTOM OF LINTEL CAVITY
QUANTITY OF #5REBAR AT TOP
WIDTH
NOMINAL
0' -
1 1
/2"
CL
R
#5 BAR IN GROUT FILLEDCELL LAP 18" MIN EACHDIRECTION W/#5 BENT BAR
#5 BARS IN GROUTFILLED CELLS
OPEN FACE OF BLOCKTO FILL THIS CELL SOLID
BOND BEAM
#5 CORNER BAR18"x18"
6"
6"
MIN
1" CLEAR SLEEVE TO PIPE
PIPE
1
2
NO EXCAVATIONBELOW THIS POINTAFTER POURING FOUNDATION
PIPE PARALLEL TO FOUNDATIONWALL
FINISH GRADEFOUNDATION WALL
PIPE
FOUNDATION
1' - 6" MIN.
4"
MIN
4"
MIN
5/8" HOLLOW CORE PLANKPER PLAN
ANGLE 6"x4"X3/8"
NOTE: EARS OF HANGERABOVE NOT SHOWN FOR CLARITY
ANGLE 6"x4" (TYP)
PLANK HANGER
TYPICAL HANGER
HSS 3"x3" (TYP)
PLANK HANGERHOLLOW CORE PLANKPER PLAN
HSS 3x3PLANK HANGER
SPECIAL UNDER-SLUG HANGER
NOTE: EARS OF HANGERABOVE NOT SHOWN FOR CLARITY
PRECAST STAIR LANDING
CMU WALLPER PLAN
PRECAST LEDGERBEAM PER PRECASTMANUF
OPENING
STEEL HEADERSWHERE REQDBY MANUF
PC
PL
AN
K S
PA
N
SPACING1/2 S STIRRUP SPACING "S"
EXTEND REINFINTO BEAM
WIDTH
BE
AM
DE
PT
H
TOP REINF
STIRRUPS PER SCHEDULE
BOT REINF
1 1/2" CLR TYP#5 REBAR EA CELL, GROUT SOLID
16" MIN BRG
AS
RE
QD
1 1
/2"
CLR
TY
P
TIE
BE
AM
DE
PT
H
HORIZONTAL REINFORCING-SEE SCHEDULE
(1) #5 CORNER REINFORCINGEACH LAYER
2'-6"
2'-6"SEEP
LAN
EXTEND ALL REINFORCINGTO FAR FACE
CONC BEAMPER PLAN
HSS BEAM PER PLANCOORDINATE LOCATIONW/ ELEVATOR MFR
CONCRETE OR CMU WALLPER PLAN
PLATE 1/2"x10"x10" W/(4) 5/8" DIA SCREW ANCHORSW/ 5" EMBEDMENT @ 7" GAGE
3/16
FT
MY
ER
S, F
L 33
907
1280
0 U
NIV
ER
SIT
Y D
R. S
UIT
E 4
02
FL
LIC
EN
SE
# A
A26
0024
74
PDS A
RCHI
TECT
URE I
NC.
FX
: 855
.835
.273
3P
H: 2
39.4
37.8
090
INF
O@
PD
Sin
conl
ine.
com
TITLE:
SHEET NO.
DATE:
JOB:
REVISIONS
ALL
IDE
AS
, DE
SIG
NS
, AN
D P
LAN
S IN
DIC
AT
ED
ON
OR
RE
PR
ES
EN
TE
D B
Y T
HE
SE
DO
CU
ME
NT
S A
RE
OW
NE
D B
Y A
ND
AR
E P
RO
PE
RT
Y O
F P
DS
AR
CH
ITE
CT
RU
E IN
C.
PD
S A
RC
HIT
EC
TR
UE
INC
. HE
RE
BY
EX
PR
ES
SLY
RE
SE
RV
ES
ITS
CO
PY
RIG
HT
AN
D O
TH
ER
PR
OP
ER
TY
RIG
HT
S IN
TH
ES
E D
OC
UM
EN
TS
. TH
ES
E P
LAN
S A
ND
DR
AW
ING
S A
RE
NO
T T
O B
E R
EP
RO
DU
CE
D, C
HA
NG
ED
OR
CO
PIE
D IN
AN
Y F
OR
M O
R M
AN
NE
R W
HA
TS
OE
VE
R W
ITH
OU
T F
IRS
T O
BT
AIN
ING
TH
E E
XP
RE
SS
WR
ITT
EN
PE
RM
ISS
ION
AN
D C
ON
SE
NT
OF
PD
S A
RC
HIT
EC
TR
UE
INC
., N
OR
AR
E T
HE
Y T
O B
E A
SS
IGN
ED
TO
AN
Y P
AR
TY
WIT
HO
UT
FIR
ST
OB
TA
ININ
G S
AID
WR
ITT
EN
CO
NS
EN
T.
©P
DS
AR
CH
ITE
CT
RU
E
INC
.
18-0100
5-17-19
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
FO
R
PO
RT
CH
AR
LOT
TE
, FL
3398
3
SELECT STRUCTURAL
SELECT STRUCTURAL12573 New Brittany Blvd
Fort Myers, Florida 33907
Phone: (239) 210-5090
Certification Auth. 28357
Project No. : 19217
1Issued for Bid10-17-19
S5.00Engineer: LG Drafter:JRA
TYPICAL DETAILS
SCALE: 3/4" = 1'-0"
TYPICAL JOINT DETAILS1 SCALE: 1/2" = 1'-0"
STEP FOOTING DETAIL2 SCALE: 3/4" = 1'-0"
FOOTING CORNER DETAIL3 SCALE: 1/2" = 1'-0"
OPENING IN MASONRY WALL5
SCALE: 3/4" = 1'-0"
PRECAST LINTEL SCHEDULE6 SCALE: 1/2" = 1'-0"
STEPPED BOND BEAM7
SCALE: NTS
PIPE THROUGH FOUNDATION4
SCALE: 3/4" = 1'-0"
HOLLOW CORE PLANK CONNECTION HANGER DETAIL8 SCALE: 3/4" = 1'-0"
PRECAST STAIR LANDING DETAIL9 SCALE: 3/4" = 1'-0"
TYPICAL PRECAST OPENING10
SCALE: 3/4" = 1'-0"
TYPICAL CONCRETE BEAM11 SCALE: 3/4" = 1'-0"
TYPICAL BEAM CORNER12 SCALE: 3/4" = 1'-0"
ELEVATOR SEPARATOR BEAM DETAIL13
CONCRETE FOOTINGPER PLAN
1 1/2" NON-SHRINK GROUT
BASE PLATE AND ANCHOR RODSPER PLAN
BLOCKOUT AS IN [04.B.002]
SLAB ON GRADEPER PLAN
STEEL COLUMNPER PLAN 1/4
3"
CLR
TYP3" CLR
EM
BE
DM
EN
TLE
NG
TH
9"
UN
O
3" MIN
ISOLATION JOINT
CENTERLINE COLUMN AND FOOTING
CJ
CJ
CJ
CJ
SECOND POURDIAMOND OR ROUND
STEEL COLUMN AND BASE PLATEPER PLAN
4" M
IN
PRECAST STAIRS-SEE ARCH DRAWINGS
CONNECTION BY MANUF
1' - 4"
1' -
0"
(2) #5 CONT
SEE FTG SCHEDULE FOR SIZE AND REINF
CONC SLAB- SEE PLAN GROUT CELLS
SOLIDBELOW SLAB
0' -
3"
CL
R
LAP REINFORCING 48 BAR DIAMETERS
@ SIM CONCSLAB ON BOTH SIDES
TOP OF FTG
0'-0"
CONCRETE COLUMNPER PLAN
SP
AC
ING
1/2
TIE
CONC SLABPER PLAN
SEE FOOTING SCHEDULEFOR SIZE AND REINF
0' -
3"
CL
R
TOP OF FTG
PER PLAN
0' - 1 1/2" CLR
DOWELS TO MATCHSIZE AND QTY OF VERTBARS, LAP 24 BAR DIA
CONC SLAB-SEE PLAN
(2) #5x CONT
1
1
1' - 0"
MIN
1' -
0"
CLR
3"
SEE FTG SCHEDULEFOR SIZE AND REINF
GROUT SOLIDBELOW GRADE
(1) #5 CONTCONC SLABPER PLAN
0' -
3"
CL
R
TOP OF FTG
PER PLAN
#5 @ 24" OC
CONCRETE SLAB,PAVERS OR GRADE
SEE FTG SCHEDULE FOR SIZE AND REINF
CONC SLABPER PLAN
GROUT CELLS SOLIDBELOW SLAB
3"
CLR
LAP DOWELS 48 BAR , DIAMETERS, MATCH SIZE & SPACING OF VERTICAL REINFORCING
T/WALL
PER PLAN
8x8 BOND BEAMW/ (1) #5 CONT
8" CMU WALLW/ #5 @ 24" OC
(1) #5 CONT CONCRETE SLABPER PLAN
SEE FTG SCHEDULEFOR SIZE AND REINF
GROUT SOLIDBELOW GRADE
3"
CLR
TOP OF FOOTING
PER PLAN
#5 @ 24" OC
#5 @ 12" OC EWTOP AND BOTTOM
#5 @ 12" OC EW- TYP 4 SIDES
KEYWAY W/WATERSTOP- CONT
CONC SLAB- SEE PLAN
1' -
0"
L4x4x1/4 W/ 5/8" DIA AB@ 24" OC AT DOOR(COORD W/ MFR)
0' - 8"
(2) #5CONT
0' -
2"
TOP OF SLAB
CMU WALL-SEE PLAN
#5 CONT
WALL BEYOND
#5 @ 12 EW (AT SUMP)
STEP FTG@ SUMP
1'-0"x1'-0"x1'-0"SUMP (BEYOND)
SEE PLAN
TYP
1' - 4"
1' -
4"
PE
R P
LA
N
#5 CONT#4 x 4'-0"@ 24" OC
48 B
AR
DIA
3"
CLR
CLR
3"
TOP OF FTG
PER PLAN
SEE FTG SCHEDULE FOR SIZE AND REINF
CONC SLABPER PLAN
GROUT CELLS SOLIDBELOW SLAB
3"
CLR
LAP DOWELS 48 BAR , DIAMETERS, MATCH SIZE & SPACING OF VERTICAL REINFORCING
CONC TIE BEAM
COL 90 DEG STDHOOK INTO TIE BEAM
EXTEND JOINT REINFINTO COLUMN ORPROVIDE DOVETAILANCHORS @ 16" OC
CLA
SS
'B' L
AP
3"
3"
COL FDNPER PLAN
WALL FDNPER PLAN
TOP OF FTG
PER PLAN
COLUMN SIZEPER PLAN
FT
MY
ER
S, F
L 33
907
1280
0 U
NIV
ER
SIT
Y D
R. S
UIT
E 4
02
FL
LIC
EN
SE
# A
A26
0024
74
PDS A
RCHI
TECT
URE I
NC.
FX
: 855
.835
.273
3P
H: 2
39.4
37.8
090
INF
O@
PD
Sin
conl
ine.
com
TITLE:
SHEET NO.
DATE:
JOB:
REVISIONS
ALL
IDE
AS
, DE
SIG
NS
, AN
D P
LAN
S IN
DIC
AT
ED
ON
OR
RE
PR
ES
EN
TE
D B
Y T
HE
SE
DO
CU
ME
NT
S A
RE
OW
NE
D B
Y A
ND
AR
E P
RO
PE
RT
Y O
F P
DS
AR
CH
ITE
CT
RU
E IN
C.
PD
S A
RC
HIT
EC
TR
UE
INC
. HE
RE
BY
EX
PR
ES
SLY
RE
SE
RV
ES
ITS
CO
PY
RIG
HT
AN
D O
TH
ER
PR
OP
ER
TY
RIG
HT
S IN
TH
ES
E D
OC
UM
EN
TS
. TH
ES
E P
LAN
S A
ND
DR
AW
ING
S A
RE
NO
T T
O B
E R
EP
RO
DU
CE
D, C
HA
NG
ED
OR
CO
PIE
D IN
AN
Y F
OR
M O
R M
AN
NE
R W
HA
TS
OE
VE
R W
ITH
OU
T F
IRS
T O
BT
AIN
ING
TH
E E
XP
RE
SS
WR
ITT
EN
PE
RM
ISS
ION
AN
D C
ON
SE
NT
OF
PD
S A
RC
HIT
EC
TR
UE
INC
., N
OR
AR
E T
HE
Y T
O B
E A
SS
IGN
ED
TO
AN
Y P
AR
TY
WIT
HO
UT
FIR
ST
OB
TA
ININ
G S
AID
WR
ITT
EN
CO
NS
EN
T.
©P
DS
AR
CH
ITE
CT
RU
E
INC
.
18-0100
5-17-19
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
FO
R
PO
RT
CH
AR
LOT
TE
, FL
3398
3
SELECT STRUCTURAL
SELECT STRUCTURAL12573 New Brittany Blvd
Fort Myers, Florida 33907
Phone: (239) 210-5090
Certification Auth. 28357
Project No. : 19217
1Issued for Bid10-17-19
S5.01Engineer: LG Drafter:JRA
DETAILS
SCALE: NOT TO SCALE
STEEL COLUMN FOOTING1 SCALE: 3/4" = 1'-0"
STEEL COLUMN BLOCKOUT2 SCALE: 3/4" = 1'-0"
PRECAST STAIR FOOTINGS3 SCALE: 3/4" = 1'-0"
TYPICAL STEMWALL FOOTING4
SCALE: 3/4" = 1'-0"
TYPICAL CONCRETE COLUMN DETAIL6 SCALE: 3/4" = 1'-0"
TYPICAL THICKENED SLAB7 SCALE: 3/4" = 1'-0"
DOOR THRESHOLD DETAIL8
SCALE: 3/4" = 1'-0"
PATIO WALL12
SCALE: 3/4" = 1'-0"
INTERIOR DOOR THRESHOLD9
SCALE: 3/4" = 1'-0"
ELEVATOR SECTION11
SCALE: 3/4" = 1'-0"
TYPICAL STEMWALL FOOTING5
SCALE: 1/2" = 1'-0"
CONCRETE COLUMN IN CMU WALL10
(1) #5 CONT
#4 @ 48" OC
24"
BOND BEAMPER PLAN
PRECAST PLANKPER PLAN
TOPPING PER PLANCMU WALLPER PLAN4
8 B
AR
DIA
LA
P
TYP3" BRG
6"
(1) #5 CONT
#4 @ 48" OC
PRECAST PLANKPER PLAN
TOPPING PER PLANCMU WALLPER PLAN
24"
6"
48 B
AR
DIA
LA
P
BOND BEAMPER PLAN
1" MIN
BOND BEAMPER PLAN
PRECAST PLANKPER PLAN
TOPPING PER PLAN
(1) #5 CONT
#4 @ 48" OC x 5'-0"
CMU WALLPER PLAN
48 B
AR
DIA
LA
P
3" BRG
PRECAST PLANKPER PLAN
TOPPING PER PLAN
(1) #5 CONT
#4 x 5'-0" @ 48" OC
BOND BEAMPER PLAN
CMU WALLPER PLAN
1" MINMIN3"
CMU WALLPER PLAN
48 B
AR
DIA
LA
P
BOND BEAMPER PLAN
PRECAST PLANKPER PLAN
TOPPING PER PLAN
(1) #5 CONT
#4 @ 48" OC x 5'-0"
CMU WALLPER PLAN
48 B
AR
DIA
LA
P
1" MIN
BOND BEAMPER PLAN
CMU WALLPER PLAN
PRECAST PLANKPER PLAN
DOWEL VERTICAL REINFORCINGINTO TOPPING
TOPPING PER PLAN
BOND BEAMPER PLAN
CMU WALLPER PLAN
#4 x 1'-4" W/3" HOOK @ 48" OC
PRECAST PLANKPER PLAN
(1) #5 CONT
BRG 3"
TOPPING PER PLAN #4 x 5'-0" @ 48" OC
PRECAST PLANKPER PLAN
TOPPING PER PLAN (1) #5 CONT
#4 x 5'-0" @ 48" OC
BOND BEAMPER PLAN
CMU WALLPER PLAN
1" MINMIN3"
CONCRETE BEAMPER PLAN
PRECAST PLANKPER PLAN
TOPPING PER PLAN
(1) #5 CONT
#4 @ 48" OC x 6'-0"
CMU WALLPER PLAN
BRG3"
48 B
AR
DIA
LA
P
(1) #5 CONT
#4 @ 48" OC 6"
24"
CONCRETE BEAMPER PLAN
PRECAST PLANKPER PLAN
TOPPINGPER PLAN
CMU WALLPER PLAN4
8 B
AR
DIA
PRECAST PLANKPER PLAN
TOPPING PER PLAN
CMU WALLPER PLAN
HOOKED DOWEL TO MATCH WALL REINF.
CONC BEAMPER PLAN
(2) COURSE BOND BEAMPER PLAN
HOOK DOWEL VERTICAL REINFORCING INTO TOPPING
5/16TYP
L6x6x3/8xCONT
EMBED PLATE 1/2"x14"x0'-9"W/ (6) 3/4" DIA HS @ 48" OC MAX
#5 DOWEL @ EA KEYWAY MAX 48" OC
2' - 6"
CONCRETE BEAMPER PLAN
PRECAST PLANKPER PLAN
TOPPING PER PLAN
(1) #5 CONT
#4 @ 48" OC x 5'-0"
MIN1"
CMU WALLPER PLAN
48 B
AR
DIA
CONCRETE BEAMPER PLAN
PRECAST PLANK &TOPPING PER PLAN
CMU WALLPER PLAN
EMBED PLATE IN PLANKMIN (2) PER SIDE PERPLANK
DOWELS INTO BEAM TO MATCHSIZE AND SPACING OF VERTICALREINFORCING
EMBED PLATE 1/2"x14"x0'-9"W/ (6) 3/4" DIA x 5" HS @ 48" OC MAX
B/BEAM
PER PLAN
L6x6x1/2xCONT
PLANK ON BOTH SIDES OF BEAM.COORDINATE DIRECTION WITH PLAN.
1/4TYP
5/16TYP
T/SLAB
PER PLAN
MIN BRG0' - 3"
PRECAST PLANKPER PLAN
TOPPING PER PLAN
(1) #5 CONT
#4 x 5'-0" @ 48" OC
CONCRETE BEAMPER PLAN
BRG1"
BRG3"
(1) #5 CONT
#4 @ 48" OC
24"
PRECAST PLANKPER PLAN
TOPPING PER PLANCMU WALLPER PLAN4
8 B
AR
DIA
LA
P
6"
CONCRETE BEAMPER PLAN
BRG3"
FT
MY
ER
S, F
L 33
907
1280
0 U
NIV
ER
SIT
Y D
R. S
UIT
E 4
02
FL
LIC
EN
SE
# A
A26
0024
74
PDS A
RCHI
TECT
URE I
NC.
FX
: 855
.835
.273
3P
H: 2
39.4
37.8
090
INF
O@
PD
Sin
conl
ine.
com
TITLE:
SHEET NO.
DATE:
JOB:
REVISIONS
ALL
IDE
AS
, DE
SIG
NS
, AN
D P
LAN
S IN
DIC
AT
ED
ON
OR
RE
PR
ES
EN
TE
D B
Y T
HE
SE
DO
CU
ME
NT
S A
RE
OW
NE
D B
Y A
ND
AR
E P
RO
PE
RT
Y O
F P
DS
AR
CH
ITE
CT
RU
E IN
C.
PD
S A
RC
HIT
EC
TR
UE
INC
. HE
RE
BY
EX
PR
ES
SLY
RE
SE
RV
ES
ITS
CO
PY
RIG
HT
AN
D O
TH
ER
PR
OP
ER
TY
RIG
HT
S IN
TH
ES
E D
OC
UM
EN
TS
. TH
ES
E P
LAN
S A
ND
DR
AW
ING
S A
RE
NO
T T
O B
E R
EP
RO
DU
CE
D, C
HA
NG
ED
OR
CO
PIE
D IN
AN
Y F
OR
M O
R M
AN
NE
R W
HA
TS
OE
VE
R W
ITH
OU
T F
IRS
T O
BT
AIN
ING
TH
E E
XP
RE
SS
WR
ITT
EN
PE
RM
ISS
ION
AN
D C
ON
SE
NT
OF
PD
S A
RC
HIT
EC
TR
UE
INC
., N
OR
AR
E T
HE
Y T
O B
E A
SS
IGN
ED
TO
AN
Y P
AR
TY
WIT
HO
UT
FIR
ST
OB
TA
ININ
G S
AID
WR
ITT
EN
CO
NS
EN
T.
©P
DS
AR
CH
ITE
CT
RU
E
INC
.
18-0100
5-17-19
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
FO
R
PO
RT
CH
AR
LOT
TE
, FL
3398
3
SELECT STRUCTURAL
SELECT STRUCTURAL12573 New Brittany Blvd
Fort Myers, Florida 33907
Phone: (239) 210-5090
Certification Auth. 28357
Project No. : 19217
1Issued for Bid10-17-19
S5.02Engineer: LG Drafter:JRA
DETAILS
SCALE: 3/4" = 1'-0"
PLANK AT BOND BEAM1 SCALE: 3/4" = 1'-0"
PLANK AT BOND BEAM2 SCALE: 3/4" = 1'-0"
PLANK AT INTERIOR WALL3 SCALE: 3/4" = 1'-0"
PLANK AT BOND BEAM4 SCALE: 3/4" = 1'-0"
PLANK AT BOND BEAM5
SCALE: 3/4" = 1'-0"
PLANK AT BOND BEAM6 SCALE: 3/4" = 1'-0"
PLANK AT BOND BEAM7 SCALE: 3/4" = 1'-0"
PLANK AT BOND BEAM8 SCALE: 3/4" = 1'-0"
PLANK BEARING AT CONCRETE BEAM9
SCALE: 3/4" = 1'-0"
PLANK AT CONCRETE BEAM13 SCALE: 3/4" = 1'-0"
CANTILEVERED SLAB SECTION14SCALE: 3/4" = 1'-0"
PLANK AT CONCRETE BEAM11
SCALE: 3/4" = 1'-0"
UPTURNED BEAM DETAIL15
SCALE: 3/4" = 1'-0"
PLANK AT CONCRETE BEAM10
SCALE: 3/4" = 1'-0"
PLANK AT CONCRETE BEAM12
BOND BEAMPER PLAN
WALL BEYOND
PRECAST PLANKPER PLAN
HOIST BEAM W8x10
L4x4x3/8x0'-6" BOTH SIDESW/ (2) 5/8" DIA SCREW ANCHORSW/ 5" EMBEDMENTINTO GROUT FILLED CELLS
TO CAP
PER PLAN
(1) #5 CONT
TOW
PER PLAN
8x8 BOND BEAMW/ (1) #5 CONT
#4 @ 28" OC MAXIN KEYWAY 24"
TOPPING PER PLAN
T/BEAM
PER MFR
24"
8x8 BOND BEAMW/ (1) #5 CONT TOW
PER PLAN
(1) #5 CONT
#4 @ 48" OC 6"
24"
BOND BEAMPER PLAN
PRECAST PLANKPER PLAN
TOPPING PER PLANCMU WALLPER PLAN
(1) #5 CONT
#4 @ 48" OC
BOND BEAMPER PLAN
PRECAST PLANKPER PLAN
TOPPING PER PLANCMU WALLPER PLAN@ SIM NOWALL ABOVE
24"
6"0' - 1" MIN
8x8 BOND BEAMW/ (1) #5 CONT T/ PARAPET
PER PLAN
PRECAST PLANKPER PLAN
CMU WALLPER PLAN
TOPPING PER PLAN
GROUT
48 B
AR
DIA
CONCRETE BEAMPER PLAN
PRECAST PLANK &TOPPING PER PLAN
EMBED PLATE 1/2"x14"x0'-9"W/ (6) 3/4" DIA x 5 HS @ 48" OC MAXSTAGGER PLATES EA SIDE OF BEAM
L6x6x1/2x CONT
#4 x 5'-0" @ 48" OC
5/16TYP
HSS - PER PLAN
AT HSS 8x8PLATE 1/2"x8 1/2"x1'-0"W/ (4) 1/2" DIA x 6" HSAT HSS 12x12PLATE 3/4" x 1'-2" x1'-6"W/ (6) 1/2" DIA x 6" HS
CMU WALLPER PLAN
48 B
AR
DIA
LA
P
PRECAST PLANK& TOPPINGPER PLAN
CMU PARAPET W/#5 VERTS @ 32" OC
BOND BEAMPER PLAN
ADDITIONAL #5 CONT @12" OC FOR OVERHANGS >1'-0"
CMU WALLPER PLAN
2' - 6"
8x8 BOND BEAMW/ (1) #5 CONT
PER ARCH
(2) #5 CONT
#6 @ 6" OC
3" BRG
PRECAST PLANK& TOPPINGPER PLAN
CMU PARAPET W/#5 VERTS @ 32" OC
BOND BEAMPER PLAN
ADDITIONAL #5 CONT @12" OC FOR OVERHANGS >1'-0"
CMU WALLPER PLAN
8x8 BOND BEAMW/ (1) #5 CONT
PER ARCH
(2) #5 CONT
#6 @ 6" OC
1" BRG
2' - 6"
8" STEEL SLEEVE FOR 6-INCH STORM PIPING, COORDINATE LOCATION W/ MEP DWGS
1/4TYP
T/BEAM
PER PLAN
HSS 6X6X1/4
POST UPPER PLAN
HSS 4x4x1/4" BRACE
PRECAST PLANK & TOPPING PER PLAN
CL
PLATE 3/4" x 12" x 1'-0"TOP & BOTTOMW/ (4) 3/4" THRU BOLTSTYPICAL GROUT CORES AROUND BOLTS
1/4TYP
HSS 6x6x1/4
WORK POINT
5' -
0"
2' -
0"
CAP PLATE 3/8"
L6x4x3/8 CENTERED BETWEEN EACH POST
1/4TYP
5' - 0"
WORK POINT
T/BEAM
PER PLAN
1/4HSS TO HSS
1/4
ANGLE TOHSS
CO
OR
D W
/ A
RC
H
2' -
0"
STEEL EXPOSED TO WEATHER SHALL BE GALVANIZED
PRECAST PLANK& TOPPINGPER PLAN
CMU WALL, SEE PLAN
CONCETE BEAMPER PLAN
ADDITIONAL #5 CONT @12" OC FOR OVERHANGS >1'-0"
CMU WALLBEYOND
#5 @ 12"OC
4' - 0"
1" BRG
CONCETE BEAMPER PLAN
10"
BOND BEAMPER PLAN
WALL BEYOND
PRECAST PLANKPER PLAN
W12x19SEPARATOR BEAM
PL 1/2x14"x1'-2" W/ (4) 3/4"DIA SCREW TYPE ANCHORSWITH 5 1/2" MIN EMBED INTOGROUT FILLED CELLS. FILL CELLS AROUND ANCHORS ASNECESSARY.
TO CAP
PER PLAN
(1) #5 CONT
#4 @ 28" OC MAXIN KEYWAY 24"
TOPPING PER PLAN
24"
CONCRETE BEAMPER PLAN
PRECAST PLANK &TOPPING PER PLAN
EMBED PLATE 1/2"x14"x0'-9"W/ (6) 3/4" DIA x 5 HS @ 48" OC MAXSTAGGER PLATES EA SIDE OF BEAM
L6x6x1/2x CONT
#4 x 5'-0" @ 48" OC
5/16TYP
CONCRETE BEAMPER PLAN
PRECAST PLANK &TOPPING PER PLAN
EMBED PLATE 1/2"x14"x0'-9"W/ (6) 3/4" DIA x 5 HS @ 48" OC MAXSTAGGER PLATES EA SIDE OF BEAM
L6x6x1/2x CONT
#4 x 5'-0" @ 48" OC
5/16TYP
FT
MY
ER
S, F
L 33
907
1280
0 U
NIV
ER
SIT
Y D
R. S
UIT
E 4
02
FL
LIC
EN
SE
# A
A26
0024
74
PDS A
RCHI
TECT
URE I
NC.
FX
: 855
.835
.273
3P
H: 2
39.4
37.8
090
INF
O@
PD
Sin
conl
ine.
com
TITLE:
SHEET NO.
DATE:
JOB:
REVISIONS
ALL
IDE
AS
, DE
SIG
NS
, AN
D P
LAN
S IN
DIC
AT
ED
ON
OR
RE
PR
ES
EN
TE
D B
Y T
HE
SE
DO
CU
ME
NT
S A
RE
OW
NE
D B
Y A
ND
AR
E P
RO
PE
RT
Y O
F P
DS
AR
CH
ITE
CT
RU
E IN
C.
PD
S A
RC
HIT
EC
TR
UE
INC
. HE
RE
BY
EX
PR
ES
SLY
RE
SE
RV
ES
ITS
CO
PY
RIG
HT
AN
D O
TH
ER
PR
OP
ER
TY
RIG
HT
S IN
TH
ES
E D
OC
UM
EN
TS
. TH
ES
E P
LAN
S A
ND
DR
AW
ING
S A
RE
NO
T T
O B
E R
EP
RO
DU
CE
D, C
HA
NG
ED
OR
CO
PIE
D IN
AN
Y F
OR
M O
R M
AN
NE
R W
HA
TS
OE
VE
R W
ITH
OU
T F
IRS
T O
BT
AIN
ING
TH
E E
XP
RE
SS
WR
ITT
EN
PE
RM
ISS
ION
AN
D C
ON
SE
NT
OF
PD
S A
RC
HIT
EC
TR
UE
INC
., N
OR
AR
E T
HE
Y T
O B
E A
SS
IGN
ED
TO
AN
Y P
AR
TY
WIT
HO
UT
FIR
ST
OB
TA
ININ
G S
AID
WR
ITT
EN
CO
NS
EN
T.
©P
DS
AR
CH
ITE
CT
RU
E
INC
.
18-0100
5-17-19
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
FO
R
PO
RT
CH
AR
LOT
TE
, FL
3398
3
SELECT STRUCTURAL
SELECT STRUCTURAL12573 New Brittany Blvd
Fort Myers, Florida 33907
Phone: (239) 210-5090
Certification Auth. 28357
Project No. : 19217
1Issued for Bid10-17-19
S5.03Engineer: LG Drafter:JRA
DETAILS
SCALE: 3/4" = 1'-0"
HOIST BEAM1 SCALE: 3/4" = 1'-0"
PLANK AT BOND BEAM WITH PARAPET3 SCALE: 3/4" = 1'-0"
PLANK AT BOND BEAM WITH PARAPET4 SCALE: 3/4" = 1'-0"
CMU WALL ON PLANK5
SCALE: 3/4" = 1'-0"
PLANK AT CONCRETE BEAM6 SCALE: 3/4" = 1'-0"
ROOF OVERHANG7 SCALE: 3/4" = 1'-0"
ROOF OVERHANG8
SCALE: 3/4" = 1'-0"
SCREEN WALL DETAIL10
SCALE: 3/4" = 1'-0"
WALL SECTION9
SCALE: 3/4" = 1'-0"
SEPARATOR BEAM DETAIL2
SCALE: 3/4" = 1'-0"
PLANK AT CONCRETE BEAM11
SCALE: 3/4" = 1'-0"
PLANK AT CONCRETE BEAM12