Watch the Video E. A. F. D. B. C. G. H. I. Cordless Drill 1/16” drill bit File #2 Phillips head screwdriver PH-00 Screwdriver KIT INCLUDES | TOOLS REQUIRED 60241 Motor Mount 60264 MM4 RM series module (w/ optional REX) 40040 Phillips Screws 50453 Bracket 40059 Cable Mounting Pad 50636 Cable Guides 40060 Cable Ties 50741 MM4 RM Cable 50436 8’ Lead A. B. C. D. E. F. G. H. I. 1- 1- 2- 1- 2- 3- 2- 1- 1- PD15-UL-M KIT INSTRUCTIONS The Command Access PD15-UL-M-KIT is a field-installable motorized latch- pullback kit for the Jackson 1285/95 & AHT 8/9 series devices. #20379_J US customer support 1-888-622-2377 | www.commandaccess.com | CA customer support 1-855-823-3002

Upload: others

Post on 06-Jul-2020

34 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PD15-UL-M KIT - Command Access...Connect MM4 Cable. Attach the strain relief and secure MM4 cable with a zip tie. 20. STEP 3 - Reassemble Exit Device 1. 2. Once guides & bumpers are

Watch the Video

E.

A.

F.D.

B. C.

G. H. I.

Cordless Drill1/16” drill bitFile#2 Phillips head screwdriverPH-00 Screwdriver

KIT INCLUDES | TOOLS REQUIRED 60241 Motor Mount 60264 MM4 RM series module (w/ optional REX)40040 Phillips Screws 50453 Bracket40059 Cable Mounting Pad50636 Cable Guides40060 Cable Ties50741 MM4 RM Cable50436 8’ Lead

A. B.C.D.E. F.G.H.I.

1-1-2-1- 2-3-2-1-1-

PD15-UL-M KIT

INSTRUCTIONS The Command Access PD15-UL-M-KIT is a field-installable motorized latch-

pullback kit for the Jackson 1285/95 & AHT 8/9 series devices.

# 2 0 3 7 9 _ J

U S c u s t o m e r s u p p o r t 1 - 8 8 8 - 6 2 2 - 2 3 7 7 | w w w. c o m m a n d a c c e s s . c o m | C A c u s t o m e r s u p p o r t 1 - 8 5 5 - 8 2 3 - 3 0 0 2

Page 2: PD15-UL-M KIT - Command Access...Connect MM4 Cable. Attach the strain relief and secure MM4 cable with a zip tie. 20. STEP 3 - Reassemble Exit Device 1. 2. Once guides & bumpers are

Step 1 • Select your preferred torque mode (ships in standard torque) Press the device push pad to the desired setting. (Recommend to fully depress and release 5%, giving the device room for changing door conditions.)

Step 2 • While depressing the push pad, apply power. (i.e. presenting the credential to the reader).

Step 3 • Continue to keep pad depressed, the device will beep 6 times. After the beeps have stopped, release the pad and now the adjustment is complete. If not to your liking repeat the 3 steps.

Setting PTS

2 Beeps

3 Beeps

5 Beeps

6 Beeps

Beeps Explanation SolutionOver Voltage

Under Voltage

Retraction or dogging failure

PUSH TO SET

> 30V unit will shut down. Check voltage & adjust to 24 V.

< 20V unit will shut down. Check voltage & adjust to 24 V.

After 1st fail: 5 beeps then immediately attempts to retract again.After 2nd fail: 5 beeps with pause in-between for 30 seconds then device attempts to retract again.After 3rd fail: 5 beeps every 7 minutes, device will not attempt to retract. To Reset: Depress bar for 5 seconds at any time.

Device is recording it’s new position and power mode after the 6th beep.

Troubleshooting & Diagnostics

4 Beeps Failed Sensor Verify all 3 sensor wires are installed correctly. Replace sensor if problem persists by contacting office.

**Important Info**Make sure to set PTS before finishing installation

Technical Information

SPECIFICATIONS• Input Voltage: 24VDC +/- 10%• Wire gauge: Minimum 18 gauge• Direct wire run - no relays or

access control units in-between power supply & module

U S c u s t o m e r s u p p o r t 1 - 8 8 8 - 6 2 2 - 2 3 7 7 | w w w. c o m m a n d a c c e s s . c o m | C A c u s t o m e r s u p p o r t 1 - 8 5 5 - 8 2 3 - 3 0 0 2

Average Latch Retraction Current: 2 AmpAverage Holding Current: 250 mA

High Torque Mode

Average Latch Retraction Current: 1 AmpAverage Holding Current: 215 mA

Standard Torque ModeMM4 Switches

2

onon

off STANDARD TORQUEHIGH TORQUE

PTS PROGRAMMING LOCKEDPTS PROGRAMMING ON

off

1

Step 4 • Once you’ve found the correct location, flip the dip switch to off to lock programming.

Page 3: PD15-UL-M KIT - Command Access...Connect MM4 Cable. Attach the strain relief and secure MM4 cable with a zip tie. 20. STEP 3 - Reassemble Exit Device 1. 2. Once guides & bumpers are

Ceiling Tile

LegendStandard Placement

Module

GREEN CHANNEL 1

LED

NORMALLY OPENDRY CONTACT FROM

ACCESS CONTROL SYSTEM

NO VOLTAGE

LOCKING HARDWARE

+-

CAT

Electrified Exit Device

INSTALLATION EXAMPLE

Recommended PoweR SuPPlieS:All Command Access exit devices & field installable kits have been thoroughly cycle

tested with Command Access power supplies at our factory.

For more information click here or go to our website

U S c u s t o m e r s u p p o r t 1 - 8 8 8 - 6 2 2 - 2 3 7 7 | w w w. c o m m a n d a c c e s s . c o m | C A c u s t o m e r s u p p o r t 1 - 8 5 5 - 8 2 3 - 3 0 0 2

Page 4: PD15-UL-M KIT - Command Access...Connect MM4 Cable. Attach the strain relief and secure MM4 cable with a zip tie. 20. STEP 3 - Reassemble Exit Device 1. 2. Once guides & bumpers are

1

12

2

STEP 1 - Disassemble Exit Device

Remove (2) screws on push pad end caps from front & back1. Pull back push pad exposing the front activating brack-

et. Remove guides and roll pin from activating bracket.2.

Once connecting rods are disconnected from front activating bracket flip device over.3. Remove head assembly by removing (2) screws.4.

Slide push pad forward to remove from device.5. 6. Underneath pushpad remove dogging assembly.

U S c u s t o m e r s u p p o r t 1 - 8 8 8 - 6 2 2 - 2 3 7 7 | w w w. c o m m a n d a c c e s s . c o m | C A c u s t o m e r s u p p o r t 1 - 8 5 5 - 8 2 3 - 3 0 0 2

Page 5: PD15-UL-M KIT - Command Access...Connect MM4 Cable. Attach the strain relief and secure MM4 cable with a zip tie. 20. STEP 3 - Reassemble Exit Device 1. 2. Once guides & bumpers are

12

1

CVR RIM

Next, we’ll be installing the kit in between the activating brackets on the exposed baserail.7. Re-attach head assembly by securing (2) screws. 8.

9.

STEP 2- Installing Kit

Add bracket #50453 to front activating bracket. Dropping it over the top and securing it with the screw provided.

10.

1/4”

1/2”PILOT HOLE IN INCHES (“)

PILOT HOLE

BEFORE

AMOUNT REMOVED IN INCHES (“)

5/16”

5/8”

AFTERBEFORE MOVING TO STEP 2 - SEE STEP C on PAGE 8

**Important Info**

U S c u s t o m e r s u p p o r t 1 - 8 8 8 - 6 2 2 - 2 3 7 7 | w w w. c o m m a n d a c c e s s . c o m | C A c u s t o m e r s u p p o r t 1 - 8 5 5 - 8 2 3 - 3 0 0 2

2

FRO

NT

On the baserail, remove the back (2) screws from the dogging bracket. 11. Make sure scissor bracket on bottom side is diagonal

& screws are flush before installing.

12

1

Page 6: PD15-UL-M KIT - Command Access...Connect MM4 Cable. Attach the strain relief and secure MM4 cable with a zip tie. 20. STEP 3 - Reassemble Exit Device 1. 2. Once guides & bumpers are

Next, drop the motor mount in with the front over the front activating bracket.

13.

12

Line up the back with the (2) available screw holes and the bracket securing the motor mount.

14. Push screws to correct position (pictured) to straighten scissor bracket and secure front end of the motor kit by tightening (2) screws.

16.

U S c u s t o m e r s u p p o r t 1 - 8 8 8 - 6 2 2 - 2 3 7 7 | w w w. c o m m a n d a c c e s s . c o m | C A c u s t o m e r s u p p o r t 1 - 8 5 5 - 8 2 3 - 3 0 0 2

12.

Push Pad

Tighten back end of the module by re-installing (2) screws from dogging bracket.

17. 18.

End of Channel

21 3

4

Slide all the way up until the MM4 bracket is almost flush with end of the channel. Tighten all (4) screws here to secure MM4

Slide MM4 module into housing’s channel on the back of the device.

Page 7: PD15-UL-M KIT - Command Access...Connect MM4 Cable. Attach the strain relief and secure MM4 cable with a zip tie. 20. STEP 3 - Reassemble Exit Device 1. 2. Once guides & bumpers are

1. Attach the wire guides to the inside of the baserail. 2. Route wires along the inside of the baserail using the wire guides.

**HOOK UP TO POWER & TEST MOTOR BEFORE MOVING ON TO STEP 5.**

19. Connect MM4 Cable. Attach the strain relief and secure MM4 cable with a zip tie.

20.

STEP 3 - Reassemble Exit Device1. 2. Once guides & bumpers are installed on activating

brackets slide on the push pad.

Back of device

Front

Re-install pins and connecting rods on both activating brackets

Rod

Connecting Rod

Page 8: PD15-UL-M KIT - Command Access...Connect MM4 Cable. Attach the strain relief and secure MM4 cable with a zip tie. 20. STEP 3 - Reassemble Exit Device 1. 2. Once guides & bumpers are

3. Turn over BACK push pad end cap over and start a pilot hole beneath the bottom right hand corner (see measurements below). Use the gold bracket as a guide. Once your hole is drilled use your preferred method to clear out the remaining debris and file to clean up the edges.

1/4”

1/2”PILOT HOLE IN INCHES (“)

PILOT HOLE

BEFORE

AMOUNT REMOVED IN INCHES (“)

5/16”

5/8”

AFTER

21

4. 1. Slide BACK push pad end cap into channel before re-installing to push pad. 2. Re-install (2) screws on BACK & FRONT push pad end caps.

5. 1. Slide filler plates on and plug into power.2. Set “Push-to-Set” and once you found the correct location, turn PTS switch to OFF position.

U S c u s t o m e r s u p p o r t 1 - 8 8 8 - 6 2 2 - 2 3 7 7 | w w w. c o m m a n d a c c e s s . c o m | C A c u s t o m e r s u p p o r t 1 - 8 5 5 - 8 2 3 - 3 0 0 2

Setting PTSStep 1- Select your preferred torque mode (ships in standard torque) Press the device push pad to the

desired setting. (Recommend to fully depress and release 5%, giving the device room for changing door conditions.)

Step 2- While depressing the push pad, apply power. (i.e. presenting the credential to the reader).

Step 3- Continue to keep pad depressed, the device will beep 6 times. After the beeps have stopped, release the pad and now the adjustment is complete. If not to your liking repeat the three steps.

Step 4- Once you found the correct location, flip the dip switches to off to lock programming.

MM4 Switches

2

onon

off STANDARD TORQUEHIGH TORQUE

PTS PROGRAMMING LOCKEDPTS PROGRAMMING ON

off

1