PCS0534 reation of C omfort C re o AIR CONDITIONING SYSTEM For high outdoor temperature use COOLING ONLY [ 60 Hz ] HEAT PUMP [ 60 Hz ] The specifications, designs, and information in this brochure are subject to change without notice. All rights reserved Printed in Japan 02/05/003 SW HP SS c Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorized parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. Warning For any inquiries, contact your local distributor. 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided and choose an outdoor unit with anti-corrosion treatment. Cautions on product corrosion Head Office: Umeda Center Bldg., 4-12, Nakazaki-Nishi 2-chome, Kita-ku, Osaka, 530-8323 Japan Tokyo Office: JR Shinagawa East Bldg., 18-1, Konan 2-chome, Minato-ku, Tokyo, 108-0075 Japan http://www.daikin.com/global/ All Daikin Industries locations and subsidiaries in Japan have received environmental management system standard ISO 14001 certification. The air conditioners manufactured by Daikin Industries have received ISO 9001 certification for quality assurance. Certificate Number. JMI-0107 JQA-0495 JQA-1452 Daikin Industries, Ltd. Domestic Group Certificate Number. EC99J2044 ISO 14001 is the standard defined by the International Organization for Standardization (ISO) relating to environmental management systems. Our group has been acknowledged by an internationally accredited compliance organisation as having an appropriate programme of environmental protection procedures and activities to meet the requirements of ISO 14001. About ISO 14001

Upload: bartamone

Post on 27-Apr-2015

625 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: PCS0534 - SkyAir 60Hz_tcm185-113920

PCS0534

r e a t io n o fCo m fo r tC

r e

o

AIR CONDITIONING SYSTEM

For high outdoor temperature use

C OOLING ONLY [60 Hz ]

HE AT PUMP [60 Hz ]

The specifications, designs, and information in this brochure are subject to change without notice.

All rights reservedPrinted in Japan 02/05/003 SW •HP •SSc

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer orcontractor to install those parts and accessories. Use of unauthorized parts and accessories orimproper installation of parts and accessories can result in water or refrigerant leakage, electricalshock, fire or explosion.Read the User's Manual carefully before using this product. The User's Manual provides importantsafety instructions and warnings. Be sure to follow these instructions and warnings.

Warning

For any inquiries, contact your local distributor.

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided and choose anoutdoor unit with anti-corrosion treatment.

Cautions on product corrosion

Head Office:Umeda Center Bldg., 4-12, Nakazaki-Nishi2-chome, Kita-ku, Osaka, 530-8323 Japan

Tokyo Office:JR Shinagawa East Bldg., 18-1, Konan2-chome, Minato-ku, Tokyo, 108-0075 Japan

http://www.daikin.com/global/

All Daikin Industries locationsand subsidiaries in Japan havereceived environmentalmanagement system standardISO 14001 certification.

The air conditioners manufacturedby Daikin Industries havereceived ISO 9001 certification forquality assurance.

Certificate Number. JMI-0107JQA-0495JQA-1452

Daikin Industries, Ltd.Domestic GroupCertificate Number. EC99J2044

ISO 14001 is the standard defined by theInternational Organization for Standardization (ISO)relating to environmental management systems.Our group has been acknowledged by aninternationally accredited compliance organisationas having an appropriate programme ofenvironmental protection procedures and activitiesto meet the requirements of ISO 14001.

About ISO 14001

Page 2: PCS0534 - SkyAir 60Hz_tcm185-113920

Cooling only

(Type without factory charged refrigerant)

19,1005.6

4,82023,2006.8

5,85027,8008.1

7,00038,90011.4

9,80048,80014.3

12,30053,90015.8

13,50099,60029.2

25,10081,80024.0

20,600163,50047.9

41,200199,40058.4

50,200

2 2.5 3 4 5 6 108 15 20kWCapacityBtu/hkcal/h

FDM03FAVAL FDM04FAVAL FDM05FAVAL FDYM06FAVAL

CEILING MOUNTEDCASSETTE TYPE

CEILING SUSPENDED TYPE

OUTDOOR UNIT

FLOOR STANDING TYPE

WALL MOUNTED TYPE

FA71FVEK FA100FVEK

FV71LAVE FV100LAVE FV125LAVE

R50GVAL R60GVAL R71FUVAL R100FUVALR125FUTAL RU06KTALR140KUTALKR125KUYALK

R140KUYALK

FHC50KVE FHC60KVE FHC71KVE FHC100KVE FH(Y)C125KVE FHYC140KVE

DUCTCONNECTION

MIDDLE STATICPRESSURE TYPE

LOW STATICPRESSURE TYPE

HIGH STATICPRESSURE TYPE

FDB50KVE FDB60KVE FDB71KVE

FH50BVE FH60BVE FH71BVE FH100BVE FH125BVE

FD06KTAL FD08KTAL FD10KTAL FD15KTAL FD20KTALFD03KVAL FD04KVAL FD05KTAL

RU08KTAL RU10KTAL RU08KTAL × 2 RU10KTAL × 2RU08KUTAL RU10KUTAL RU08KUTAL × 2 RU10KUTAL × 2

R50GVAL R60GVAL R140KUTALK/YALKR125FUTAL(R125KUYALK)R100FUVALR71FUVAL

R140KUTALKR125FUTALR100FUVALR71FUVAL

R50GVAL R60GVAL R125FUTALR100FUVALR71FUVAL

R50GVAL R60GVAL

R100FUVALR71FUVAL

R125FUTALR100FUVALR71FUVAL

RU08KUTAL RU10KUTALRU06KTALR125FUTALR100FUVALR71FUVAL

R71FUVAL

RU08KUTAL × 2 RU10KUTAL × 2RU08KTAL RU10KTAL RU08KTAL × 2 RU10KTAL × 2

Page 22Specifications

Page 22Specifications

Page 23Specifications

Page 23Specifications

Page 24Specifications

Page 24Specifications

Page 25– 26Specifications

Page 9– 11

Page 12

Page 14

Page 14

Page 15– 16

Page 17– 18

HP

PACKAGED AIR CONDITIONERS

Outdoor unitIndoor unit

Outdoor unitIndoor unit

Outdoor unitIndoor unit

Outdoor unitIndoor unit

Outdoor unitIndoor unit

Outdoor unitIndoor unit

Outdoor unitOutdoor unit

Indoor unit

1 2

Notes)•*Capacities of FD series are gross capacities which do not include a deduction for evaporator fan motor heat.*1. The values given on the right are for the FHYC type. Values for other types may differ slightly.The values given for 8HP to 20HP are for the FD type.

*1

Page 3: PCS0534 - SkyAir 60Hz_tcm185-113920

TRIPLE MULTI OPERATION

Page 19– 20 Page 27– 28Specifications

Outdoor unitIndoor unit

Outdoor unitIndoor unit

Outdoor unitIndoor unit

Outdoor unitIndoor unit

Outdoor unitIndoor unit

Outdoor unitIndoor unit

Page 17– 18

75,80022.2

19,10075,80022.2

19,10090,80026.6

22,900

kWBtu/hkcal/h

HP

R200KUYAL

OUTDOOR UNIT

FDYM03FAVAL × 3

FHYC50KVE × 3 FHYC71KVE × 3 FHYC50KVE × 4 FHYC60KVE × 4

FHY50BVE × 3 FHY71BVE × 3 FHY50BVE × 4 FHY60BVE × 4

R200KUYAL R250KUYAL

8 8 106

*1. The values given on the right are for the FHYC type.

*1. The values given on the right are for the FHYC type.

53,90015.8

13,500

R140KUTALK R200KUTAL R200KUTAL R250KUTAL

R140KUTALK R200KUTAL/YAL R200KUTAL/YAL R250KUTAL/YAL

R140KUTALK R200KUTAL/YAL R200KUTAL/YAL R250KUTAL/YAL

R200KUTAL/YAL

Cooling only

3 4

Capacity *1

kWBtu/hkcal/h

HPCapacity *1

CEILING MOUNTEDCASSETTE TYPE

CEILING SUSPENDEDTYPE

DUCT CONNECTIONMIDDLE STATIC PRESSURETYPE

Page 17– 18

OUTDOOR UNIT

CEILING MOUNTEDCASSETTE TYPE

CEILING SUSPENDEDTYPE

DUCT CONNECTIONMIDDLE STATIC PRESSURETYPE

Simultaneous operation system Simultaneous operation systemDOUBLE TWIN MULTI OPERATIONPage 19– 20Page 27– 29Specifications

TWIN MULTI OPERATIONSimultaneous operation systemPage 19– 20

Page 27– 29Specifications

53,90015.8

13,50090,80026.6

22,900

FHYC125KVE × 2FHYC71KVE × 2

FHY71BVE × 2 FHY125BVE × 2

6 10

FDYM05FAVAL × 2

R250KUYAL

R140KUTALK R250KUTAL/YAL

R140KUTALK R250KUTAL/YAL

R250KUTAL/YAL

R140KUTALK R250KUTAL

75,80022.2

19,100

FHYC100KVE × 2

FHY100BVE × 2

8

FDYM04FAVAL × 2

R200KUYAL

R200KUTAL/YAL

R200KUTAL/YAL

R200KUTAL/YAL

R200KUTAL

Simultaneous control with2 units in spacious room

Simultaneous control with3 units for irregularly shaped room

Large room air conditioned bysimultaneous control of fourdistributed units

Simultaneously running2 to 4 units completelydistributes comfort acrosswide spaces.

Page 4: PCS0534 - SkyAir 60Hz_tcm185-113920

Heat pump

kWBtu/h

HP

kcal/h38,90011.4

9,80048,80014.3

12,30053,90015.8

13,50019,8005.8

4,99022,2006.5

5,59027,8008.1

7,000

4 5 62 2.5 3

kWBtu/hkcal/h

43,70012.8

11,00055,20016.2

13,90061,90018.1

15,600

75,70022.2

19,100

8

79,20023.2

20,000

92,50027.1

23,300

10

100,70029.5

25,400

148,00043.5

37,400

15

153,00044.8

38,500

181,00053.0

45,600

20

194,00056.8

48,80021,5006.3

5,42024,5007.19

6,18030,6009.0

7,700

Cooling

Heating

FDY08KATAL/YAL FDY10KATAL/YAL FDY15KATAL/YAL FDY20KATAL/YAL

FDYM03FAVAL FDYM04FAVAL FDYM05FAVAL FDYM06FAVAL

FHYC50KVE FHYC60KVE FHYC71KVE FHYC100KVE FHYC125KVE

FHYB71FVAL FHYB100FVAL FHYB125FVAL

FAY100FVE

FVY71LAVE FVY100LAVE FVY125LAVE

RY50GVAL RY60GVAL RY71FUVAL RY100FUVAL RY125FUTAL

FHYC140KVE

LOW STATIC PRESSURETYPE

MIDDLE STATIC PRESSURETYPE

HIGH STATIC PRESSURETYPE

FDYB50KAVE FDYB60KAVE FDYB71KAVE

FHY50BVE FHY60BVE FHY71BVE FHY100BVE FHY125BVE

RY200KUYAL RY250KUYAL RY200KUYAL × 2 RY250KUYAL × 2RY200KUTAL

RY140KUYALKRY140KUTALK RY250KUTAL RY200KUTAL × 2 RY250KUTAL × 2

RY50GVAL RY60GVAL RY71FUVAL RY100FUVAL RY125FUTAL RY140KUTALK/YALK

RY50GVAL RY60GVAL RY71FUVAL RY100FUVAL RY125FUTAL

RY71FUVAL RY100FUVAL RY125FUTAL

RY71FUVAL RY100FUVAL

RY71FUVAL RY100FUVAL RY125FUTAL

RY50GVAL RY60GVAL RY71FUVAL

RY71FUVAL RY100FUVAL RY125FUTAL RY140KUTALK

RY200KUTAL/YAL RY250KUTAL/YAL RY200KUTAL/YAL × 2 RY250KUTAL/YAL × 2

Page 9– 11

Page 12

Page 13

Page 14

Page 14

Page 17– 18

PACKAGED AIR CONDITIONERS

Outdoor unitIndoor unit

Outdoor unitIndoor unit

Outdoor unitIndoor unit

Outdoor unitIndoor unit

Outdoor unitIndoor unit

Outdoor unitIndoor unit

Outdoor unitIndoor unit

Outdoor unitIndoor unit

FAY71FVE

5 6

Notes)•*Cooling capacities of FDY series are gross capacities which do not include a deduction for evaporator fan motor heat.*1. The values given on the right are for the FHYC type. Values for other types may differ slightly.The values given for 8HP to 20HP are for the FDY type.

OUTDOOR UNIT

Page 30Specifications

CEILING MOUNTED CASSETTE TYPE

Page 30Specifications

CEILING SUSPENDED TYPE

Page 31Specifications

CEILING MOUNTED BUILT-IN TYPE

Page 31Specifications

WALL MOUNTED TYPE

Page 32Specifications

Page 33Specifications

Page 32Specifications

Page 34Specifications

FLOOR STANDING TYPE

DUCTCONNECTIONPage 15– 16

Capacity *1

Page 5: PCS0534 - SkyAir 60Hz_tcm185-113920

Cooling /Heating

Heat pump

Simultaneous control with2 units in spacious room

Simultaneous control with3 units for irregularly shaped room

Large room air conditioned bysimultaneous control of fourdistributed units

Simultaneously running2 to 4 units completelydistributes comfort acrosswide spaces.

53,900/61,90015.8/18.1

13,500/15,60075,800/77,50022.2/22.7

19,100/19,50090,800/97,00026.6/28.4

22,900/24,400

FHYC100KVE × 2 FHYC125KVE × 2FHYC71KVE × 2

FHY71BVE × 2 FHY100BVE × 2 FHY125BVE × 2

6 8

75,800/77,50022.2/22.7

19,100/19,500

8

75,800/77,50022.2/22.7

19,100/19,500

8

10

90,800/97,00026.6/28.4

22,900/24,400

10

FDYM04FAVAL × 2 FDYM05FAVAL × 2

FHYC50KVE × 3 FHYC71KVE × 3

FHY50BVE × 3 FHY71BVE × 3

RY200KUYAL RY250KUYALRY140KUTALK

RY140KUTALK

RY200KUTAL

RY200KUYALRY200KUTAL

RY200KUYALRY200KUTAL

RY250KUTAL

RY250KUYAL

RY140KUTALK RY200KUTAL/YAL RY250KUTAL/YAL

RY140KUTALK RY200KUTAL/YAL RY250KUTAL/YAL

RY200KUTAL/YAL RY250KUTAL/YAL

RY140KUTALK RY200KUTAL/YAL RY200KUTAL/YAL RY250KUTAL/YAL

RY140KUTALK RY200KUTAL/YAL RY200KUTAL/YAL RY250KUTAL/YAL

RY200KUTAL/YAL RY200KUTAL/YAL RY250KUTAL/YAL

RY200KUTAL/YAL

RY250KUTAL

FDYB71KAVE × 3

FHYC50KVE × 4 FHYC60KVE × 4

FHY50BVE X 4 FHY60BVE × 4

FDYM03FAVAL × 3

106

FDYB50KAVE × 4 FDYB60KAVE × 4

Outdoor unitIndoor unit

Outdoor unitIndoor unit

Outdoor unitIndoor unit

53,900/61,90015.8/18.1

13,500/15,600

7 8

TWIN MULTI OPERATIONSimultaneous operation systemPage 19– 20

Page 34– 36Specifications

TRIPLE MULTI OPERATIONSimultaneous operation systemPage 19– 20

Page 34– 36Specifications

Page 19– 20 Page 34– 36Specifications

Simultaneous operation systemDOUBLE TWIN MULTI OPERATION

kWBtu/hkcal/h

HPCapacity *1

CEILING MOUNTEDCASSETTE TYPE

CEILING SUSPENDEDTYPE

DUCT CONNECTIONMIDDLE STATIC PRESSURE TYPE

Cooling /Heating

Outdoor unitIndoor unit

Outdoor unitIndoor unit

Outdoor unitIndoor unit

kWBtu/hkcal/h

HPCapacity *1

CEILING MOUNTEDCASSETTE TYPE

CEILING SUSPENDEDTYPE

DUCT CONNECTIONLOW STATIC PRESSURE TYPE

Outdoor unitIndoor unit

DUCT CONNECTIONMIDDLE STATIC PRESSURE TYPE

Page 17– 18

OUTDOOR UNIT

Page 17– 18

OUTDOOR UNIT

*1. The values given on the right are for the FHYC type.

Page 6: PCS0534 - SkyAir 60Hz_tcm185-113920

10

Diffuser

3-Dimensional blade

Quiet design

Compact and aesthetic square panel type

Uses the newly developed "Diffuser Turbo Fan" with applicationof aircraft technology.

Quiet operation is realized by a unified structure of 3-dimensionalblades and air diffuser for arranging the flow of air in the airconditioner.

Uniform panel size for all models.The conventional 100– 140models' rectangular panel types have all beenconverted to the same compact square type as the 50– 71models. Thispermits smooth interior harmony of ceilings with the lighting fixtures.Installation of multiple air conditioners of different capacities will also be

FH(Y)C71K 35 dB 30 dBFH(Y)C125K 42 dB

Indoor unit

Note: Operating sound may increase more than that when used with 3-way air flowor 2-way air flow, or when used together with a optional kit.

High Low

36 dB

Top class of the industry

Super cassette type is more compact, lighter andeasier to install than the conventional types.Maintainability also greatly improved.

Simplifies height adjustment of the mainunit.Adjustment pockets in the four corners ofthe panel make height adjustment of themain unit much easier.

Main unit is lighter and more compact tofurther simplify installation

Because of the light weight, suspension is possible without anupper lift.

Provided with high lift drainwater lift-up mechanism(Increased lift of drain pipe upto 750 mm from the ceiling).

The FH(Y)C50K– 71K are thinmodels (230 mm) which canbe installed in narrow falseceiling space.

Min. 245 mm

FH(Y)C100K– 140K

750 mm

Two Select thermo-sensors

Thermo-sensors on both indoor unit and wired remote con-troller (option). Temperature detection can be set closer tothe living area to further improve comfort level.* Indoor unit's thermo-sensor must be used when the air conditioner is controlled

from another room. (Wireless remote controller does not have a thermo-sensor.)

( FHYC125F)

100~140

50~71

50( )

9

There are 3 patterns in auto swing operation

Swings within the range of 10° to 65°. Swing angle is set from 10° to 40° sopeople are not subjected to strong winds(Recommended where there are seats nearthe air conditioner).

Swing angle is within a range of 30° to 65°

to prevent blowing against the ceiling. (Thisrecommended for those who are particularabout cleanliness of the ceiling).

10° 10°

40° 40°30° 30°

65° 65°

10° 10°

65° 65°

•Has been set to standard setting at time of shipment. This can be changed using the remote control.

Pattern 1 Standard setting

CEILING-MOUNTED CASSETTE TYPE

Sound level

3 5 /3 0 dB[High] [Low]

FHYC71K

CEILING MOUNTED CASSETTE TYPEF H (Y )C 5 0 – 1 4 0 K

Freedom of selection of installation location

Since a multi-flow system is used, 4-way, 3-

way or 2-way air flow can easily be

selected, permitting installation in

locations corresponding to interior

Can also be installed in high ceilings.

Max. 4.2 m

Pattern 2 Draft prevention setting Pattern 3 Setting to prevent soiling of ceiling

Number of air flow outlets used

3-wayair flow

FH(Y)C50K–71K FH(Y)C100K–140K

3.0 m

3.3 m

3.5 m

3.5 m

3.8 m

4-wayair flow

2.7 mStandard

High ceiling

High ceiling

3.0 m

3.5 m

3-wayair flow

3.6 m

4.0 m

4.2 m

2-wayair flow

2-wayair flow

4.2 m

4.2 m

4-wayair flow

3.2 m

3.6 m

4.2 m

Ceilingheight

Note: Set to standard 4-way air flow when shipped.High ceiling types and will be set forremote control operation.

Criteria for ceiling height and number of air flow outlets

Note : For 3-way or 2-way air flow installation,the sealing member (option) for airdischarge outlet must be used toclose off the unused outlet(s).

(FHYC100K–140K)

Wired LCD remote controller Wireless LCD remote controller

A signal rec eiver must beadded to the indoor unit.

Wireless remote c ontroller and signalrec eiver unit are sold as a set.

Note: R emote c ontroller c able notinc luded. C ables must beproc ured loc ally.

Accessory required for indoor unit (option)

BRC1C61

Signal receiver unit(Installed type)

BRC7C613W(for c ooling only type)

BRC7C612W(for heat pump type)

Page 7: PCS0534 - SkyAir 60Hz_tcm185-113920

11 12

Soiling of ceiling reduced 30– 40% (compared to conventional models).

Maintenance is simple

Maintenance cost is reduced by using a high-efficiency long-life filtersince maintenance is required only once every 3 years as comparedto once every 2 years as was previously the case.

Maintenance cost reduced since cleaning of the heat exchangeris only necessary once every 3 years.

Cleaning is simple because of the "Non-dew Flap" with no flocking.

Although flocking is presently used on flaps to prevent dewing, thenew flaps are "Non-dew Flaps" that do not soil easily and are easy to

A high efficiency mildew-proof long-life filter is provided asstandard parts. Maintenance not required for about one year(2, 500 hrs).

The ceiling tends to become soiled bydust in the air temporarily blowing outhorizontally when resetting the flap angle.

Thanks to the stepping motor,the flap canbe set to the new setting directlypreventing soiling due to the air flow nothitting the ceiling.

Horizontaldischarge

Newly set angle

Presently set angle

Newly set angle

Stepping motor

Presently set angle

New systemConventional system

Non-dew flap

(Conventional model) (New model)

Once

2years

Once

3years

Heat pump only

(Option)

Fresh air intake kit (Option) Branch duct chamber (Option)

In addition to discharging air from the outlet on the decoration panel,a duct can be connected to the air conditioner itself for an additionaldischarge outlet. The additional discharge outlet is useful for areaswhich tend to be crowded or near doors or windows where thetemperature is affected by the outside temperature.

Note : Intake duct, hood, air filter, insect screen, fireproof damper, etc. must be procured at a local outlet if needed.

Allows intake of fresh air from the outdoors. When neither heatingnor cooling is required, fresh air can be circulated by only using thefan. This is especially useful in buildings in which ventilation fans

Three types of kits are available forspecific installation conditions.For the details, see page.37. Notes : Use only one branch duct chamber per air conditioner.

Close the decoration panel's outlet on the chamber installation side with the sealerfor the air discharge outlet.

Discharge ductBranch duct chamber

Discharge panel

Note :Discharge duct, discharge panel, etc.must be procured at a local outlet ifneeded.

Using the optional accessories produces an even higher level of comfort

Intake ductFresh air intake kit (Outdoor)

Hood

Air filter

3 9 /3 5 dB[High] [Low]

FHY71B

CEILING SUSPENDED TYPECEILING SUSPENDED TYPE

Sound level

Heat pump only

F H (Y )5 0–1 2 5 B

Two Select thermo-sensors

Thermo-sensors on both indoor unit and wired remote con-troller (option). Temperature detection can be set closer tothe living area to further improve comfort level.* Indoor unit's thermo-sensor must be used when the air conditioner is controlled

from another room. (Wireless remote controller does not have a thermo-sensor.)

Auto-swing for comfort in all directions.

Wide air discharge openings produce a spreading 100° air flow.

Installable on ceilings3. 5 m high.

Distributes comforting air flow throughout the room

Upgrade to an even more quiet andcompact system.

Maintenance is simple100°

New model

Two time settings (2500 hrs and 1250 hrs) are available to match the installationenvironment. Maintenance time warning is displayed on the remote controller(filter sign).

Long-life filter lasts about 1 year *Maintenance not required.* For dust concentration of 0.15 mg/m3

Drain-up kit (option) can beeasily incorporated.

Drain-up kit (built inside main unit)

600 mm

Wired LCD remote controller Wireless LCD remote controller

A signal rec eiver must beadded to the indoor unit.

Wireless remote c ontroller and s ignalrec eiver unit are sold as a set.

Note: R emote c ontroller c able notinc luded. C ables must beproc ured loc ally.

Accessory required for indoor unit (option)

BRC1C61 Signal receiver unit(Installed type)BRC7E66

(for c ooling only type)

BRC7E63W(for heat pump type)

Page 8: PCS0534 - SkyAir 60Hz_tcm185-113920

1413

CEILING MOUNTED BUILT-IN TYPE

With the use of simple ducts, discharge outlets can belocated in a multitude of ways. Top priority given to interiordecor, built-in type units realize ideal air current distribution.

By separating the air outlet from the main unit and blowing air, variousconditions will be cleared such as in modified stores, state of sunshineand gathering of people to realize comfortable air conditioning.

4 1 /3 5 dB[High] [Low]

FHYB71F

CEILING MOUNTED BUILT-IN TYPEF H Y B 7 1–1 2 5 F

Sound level

Highly Flexible for Various Application

Highly flexible installation is possible with a complete line-up of optional kits to satisfy the various needs, such asthe design concept, interior decoration and so on.

Long-life Filter is provided as a standard accessory.

Drain-up pump is equipped as Standard accessory with250 mm lift.

The unit can be installed, if there is a space of 350 mmabove ceiling. (when suction panel is used.)

Min.350 mm

250 mm

Standard

With duct (case 1)

With duct (case 2)

Cassette style (standard filter)

Cassette style (high efficiency filter)

Long-life filter

Long-life filter

Air suctioncanvas bellows*

Air suction panel*

Installation examples(*Optional parts)

Air suction panel*

Access panel* Access panel*

Access panel*

Air suctioncanvas bellows*

Ceiling returnLong-life filterLong-life filter

Screeningdoor*

Screeningdoor*

High-efficiencyfilter*

(Option)

Wired LCD remote controller

Note: R emote c ontroller c able notinc luded. C ables must beproc ured loc ally.

Accessory required for indoor unit (option)

BRC1C61

WALL MOUNTED TYPE

Wall mounted type units feature the lowest soundlevels in the industry and greatly upgraded comfort,thanks to the high fan speed mode.

"High fan speed mode" for further comfort.If an indoor "High fan speed mode" type unit isinstalled in a long, narrow store or in the cornerof a room,there is approximately a 10% increasein air volume. A comfortable air stream will reachdistant areas.

WALL MOUNTED TYPEF A (Y ) 7 1 /1 0 0 F

4 1 /3 7 dB[High] [Low]

FAY71F(Cooling)

Sound level

FLOOR STANDING TYPE

Floor standing type units are easy to installand maintain; their slimness is suitable forinstallation in high-ceiling stores and offices.

The panel can also be removed and used for remotecontrol such as controlling air conditioning from adifferent room or from near the cashier.

FLOOR STANDING TYPEF V (Y )7 1–1 2 5 L A

4 1 /3 5 dB[High] [Low]

FVY71LA

Sound level

These units are number one in the world in quietness and lightness.The use of a high-efficiency, long-life filter reduces maintenance time and cost.

The heat exchanger has been subjected to antibacterial treatment and mildew proofing.

Filter

Maintenance cycle

Heat exchanger

Parts Previous model New model

Once2 weeks

Once2 year

Once1 year

Once3 year

Heat pump only

Liquid crystal control panel(Standard equipment)

Signal receiver unit

Wired LCD remote controller Wireless LCD remote controller

A signal rec eiver must beadded to the indoor unit.

Wireless remote c ontroller and s ignalrec eiver unit are sold as a set.

Note: R emote c ontroller c able notinc luded. C ables must beproc ured loc ally.

Accessory required for indoor unit (option)

BRC1C61(Installed type)BRC7C69W

(for c ooling only type)

BRC7C64W(for heat pump type)

Heat pump only

Page 9: PCS0534 - SkyAir 60Hz_tcm185-113920

16

These duct type air conditioners can be installed in the ceiling spacefor an attractive interior finish. Daikin's middle static pressure duct typeair conditioners are compact and quiet, well-suited for use in a widevariety of duct type air conditioning systems for homes, stores, andoffices.

DUCT CONNECTION MIDDLE STATICPRESSURE TYPEDUCT CONNECTION MIDDLE STATICPRESSURE TYPE F D (Y ) M 0 3 –0 6 F A

[Low]4 2 dBFDM03FA

Sound level

•The duct system allows the most efficient location of discharge outlets inaccordance with the room layout.

Air c onditioner295 mm

Ordinary duc t(proc ured loc ally)

Ordinary duc t(proc ured loc ally)

Air blow Air intake

305 mm or more

Superior freedom of layout

•The standard-equipment rear intake chamber simplifies the ductconnecting work.

•Compact, 295 mm height design makes installation possible where theceiling space is limited.

Note : The under-door cutout method should be used onlywhen there is a small volume of air flow.

Ventilation grille Ventilation grille Under-door cutout

Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)

Door-installedventilation grille

Wall-installedventilation grille Under-door cutout

When air conditioning two rooms simultaneously, the airdischarged into each room must be circulated back to the airconditioner. To ensure this, a ventilation duct should beinstalled for each room or one of the indicated ventilationgrilles should be installed on the partitioning wall or under thedoor between the rooms.

Ventilates air through thepartitioning wall. (see right)

Partitioning wall

15

Heat pump only

Wired LCD remote controller Wireless LCD remote controller

A signal rec eiver must beadded to the indoor unit.

Wireless remote c ontroller and signalrec eiver unit are sold as a set.

Note: R emote c ontroller c able notinc luded. C ables must beproc ured loc ally.

Accessory required for indoor unit (option)

BRC1C61 Signal receiver unit(Separate type)

BRC4C62 (for heat pump type)

BRC4C64 (for c ooling only type)

Signal receiver unit

Wired LCD remote controller Wireless LCD remote controller

Wireless remote c ontroller and s ignalrec eiver unit are sold as a set.

Note: R emote c ontroller c able notinc luded. C ables must beproc ured loc ally.

BRC1C61(Separate type)

BRC4C62

A signal rec eiver must beadded to the indoor unit.

DUCT CONNECTION LOW STATICPRESSURE TYPE

DUCT CONNECTION HIGH STATICPRESSURE TYPE

By placing the main unit into the false ceiling, the room'sdesign and finish remain beautiful and undisturbed. Togetherwith minimal operating sound,the units are perfect for roomswhere atmosphere is important.

DUCT CONNECTION LOW STATICPRESSURE TYPE F D (Y )B 5 0–7 1 K (A )

High static pressure that allows long duct and longrefrigerant piping enables flexible installation.Recommended for spacious and large-volume areas likelarge stores or factories.

DUCT CONNECTION HIGH STATICPRESSURE TYPE F D (Y )0 3–2 0 K (A )

4 1 /3 8 dB[Low]

FDB50K

[High]

Sound level

Note: The unit shown in the photo is a dedicated cooling type.Switch box dimensions differ for combination cooling/heating type.

[Low]4 6 dBFD03K

Sound level

FD05K FDY15KA

Suction Chamber(standard equipment)

Air Filter (Field supply)fig.1.0.

Heat pump only

Heat pump onlyCooling only

Accessory required for indoor unit (option)

KRC47-2 / KRC47-4 KRC47-1

Digital remote controller Remote controllerFor cooling only type

Wired LCD remote controller Wireless LCD remote controller

Wireless remote c ontroller and signalrec eiver unit are sold as a set.

Note: R emote c ontroller c able notinc luded. C ables must beproc ured loc ally.

BRC1C61

BRC4C62

A signal rec eiver must beadded to the indoor unit.

Signal receiver unit(Separate type)

KRC47-5 KRC47-3

Digital remote controller Remote controller

For heat pump type

For cooling only type

Accessory required for indoor unit (option)

For heat pump type

FDY08-10KA only

Page 10: PCS0534 - SkyAir 60Hz_tcm185-113920

1817

Auto-swing Timer selector

High ceilingapplication

Long life filter High fanspeed mode

Twin / triple /double twin multiapplication(See page 19–20)

Program "Dry" Fan operationmode

Mold resistanttreatment for filter

Anti-corrosiontreatment ofoutdoor heatexchanger fins

Self diagnosisfunction

Auto-restart

Ceiling soilingprevention

Fresh air intake

Filter sign

OPTIONALFUNCTIONS

Main functions for extra comfort.*Please look for available functions for the model you select.Greater of corrosion resistance

Construction.

Against acid corrosionAgainst salt corrosion

Non-treated finNon-treated fin

Aluminium

PE fin PE fin

11 5– 6 5– 6Corrosion

resistance grade

AluminiumC orros ion res istanc e ac rylic res in

Hydrophilic film

Also adapts to year-round cooling

RY200KU and RY250KU can adapt up to 0°C.(Heat pump only)

200 and 250 models can be combined forcentralized, horizontal-series installationCommon width and depth make series installation easy.

RU08/10K models are availablein two types depending oninstallation conditionsRU08/10KU models are factory shipped withrefrigerant charged for 5 meters of piping.RU08/10K models are factory shipped with norefrigerant charged.

Outdoor Unit

Two selectthermo-sensors

Draft preventivefunction

Automatic Cool/HeatChange-over

Hot start

R50GR60GRY50G R(Y)71FU R(Y)100/125FU

R(Y)200KU R(Y)250KURU08K(U)R125KU

RU06KR(Y)140KU

RU10K(U)

RY60G

Flexible designfor large room ormulti-use

Piping can be drawn out from three directions - front, left side, or below.

Max. length Max. heightdifference

Pre-charged*1

50 m(Equivalent length 70 m) 30 m

50 m(Equivalent length 70 m) 30 m

5 mR(Y)200KU

5 mR(Y)250KU

Note: 1Additional refrigerant charging is required if the refrigerant pipe islonger than the indicated length.

Allowable refrigerant pipe length and height difference

R(Y)250KU

1280 mm

R(Y)200KU

1280 mm

R(Y)200KU

1280 mm

690 mm

Reduces installation space.Equipped with "high static pressure" fan.

Long hypotenuse blades with a gentle camber make the pressure rise on thesurface of the blades smooth and uniform, while suppressing break away ofthe flow. As a result, it prevents rise in draft resistance produced due to lack ofopen space behind the unit, and prevents air power from dropping.

"Air Flow Adjustment Guide" (standard equipment).Cross-section of "Air Flow Adjustment Guide".

As show in the diagram, the air flow adjustment guide is factory setso that exhaust air flow is inclined 30 degrees. The guide can be setto direct the air flow to the left, right or down as well as upward, soyou can adjust the direction according to the place of installation.

Outdoor units include as standard equipment the "Air Flow AdjustmentGuide" which lets you set as desired the air flow in any one of fourdirections in accordance with your layout. Cushions effect of air flowstriking against obstructions in front of the unit (walls,etc.) and prevents"short circuits" from being formed.

Anti-Corrosion treatment of heat exchange fins.The special acrylic precoated fin (PE fin) for anti-corrosion treatmenton the outdoor unit heat exchanger ensures greater resistance againstsalt damage and atmospheric pollution than ever.

R125KUYALK has been added to the list ofmodels capable of operating with outdoor airtemperatures of up to 54°C.

Long hypotenuse blades(Optimal camber)

500

50

30°

( Applies to R71–125FU and 140KU )

( Applies to R71–125FU and 140KU )

( Applies to all outdoor units )

(Refer to the Specifications for details on other model)