parking numbers fitzpatrick+partners
TRANSCRIPT
N
13 13
8690
1364
139
6413
WT315
WT326
WT401
VA
RIES
REFE
R TO
S.E
.D.
140
140
190
190
509
5963
1350
63
135063
WT202
WT202A
WT411
WT403B
WT403A
WT201
WT201A
WT101 IN-SITU CONCRETE
WALL TYPES SCHEDULE
190 CONCRETE BLOCK
190 CORE-FILLEDCONCRETE BLOCK
140 CONCRETE BLOCK
140 CORE-FILLEDCONCRETE BLOCK
50MM FURRING CHANNELS+ INSULATION + 9MM FC SHEET
50MM FURRING CHANNEL +INSULATION +FIBRE CEMENT
50MM FURRING CHANNEL +INSULATION +FIRE RATED PLASTERBOARD
50MM FURRING CHANNELS+ INSULATION
+ 13MM FIRE RATED PLASTERBOARD
50MM FURRING CHANNEL +INSULATION +PLASTERBOARD
50MM FURRING CHANNELS+ INSULATION
+ 13MM PLASTERBOARD
PLASTERBOARD
13MM PLASTERBOARDDIRECT STICK
13MM PLASTERBOARD+ 64 STUDS
+ 13MM PLASTERBOARD
13MM PLASTERBOARD+64 STUDS + INSULATION
+ 9MM FC SHEET
PLASTERBOARD +64MM STUD +INSULATION +FIBRE CEMENT
PLASTERBOARD +64MM STUD +PLASTERBOARD
REFER TO BCA FOR FIRERESISTANCE REQUIREMENTS
REFER TO STRUCT. ENG.DRAWINGS FORWALL REQUIREMENTS
REFER TO BCA FOR FIRERESISTANCE REQUIREMENTS
REFER TO STRUCT. ENG.DRAWINGS FORWALL REQUIREMENTS
REFER TO BCA FOR FIRERESISTANCE REQUIREMENTS
REFER TO STRUCT. ENG.DRAWINGS FORWALL REQUIREMENTS
REFER TO BCA FOR FIRERESISTANCE REQUIREMENTS
REFER TO STRUCT. ENG.DRAWINGS FORWALL REQUIREMENTS
REFER TO BCA FOR FIRERESISTANCE REQUIREMENTS
REFER TO STRUCT. ENG.DRAWINGS FORWALL REQUIREMENTS
REV. DATE DESCRIPTION CHK10
09
08
07
06
05
04
03
02
1/12/2020
19/11/2020
23/10/2020
20/10/2020
25/09/2020
12/05/2020
16/04/2020
30/03/2020
28/02/2020
FOR CONSTRUCTION
FOR COORDINATION
FOR COORDINATION 100%
FOR COORDINATION
FOR COORDINATION
FOR TENDER
FOR TENDER
DESIGN DEVELOPMENT
ISSUE FOR COORDINATION
RP
RP
RP
RP
RP
BC
BC
BC
BC
FOR CONSTRUCTION
AMENDMENTS
CLIENT
PROJECT
GENERAL ARRANGEMENT PLANS -LEVEL 1
50mm ON ORIGINAL
LIVERPOOL HEALTH & ACADEMICPRECINCT
PROJECT NORTH
DRAWING
SCALE PROJECT NO.
14/77 PACIFIC HWY, NORTH SYDNEY NSW 2060
© Copyright 2018p. +61 (0)2 8274 8200 w. www.fitzpatrickpartners.coma. LEVEL 6, 9 CASTLEREAGH STREET, SYDNEY 2000, AUSTRALIA
fitzpatrick partners+
ELIZABETH STREET LIVERPOOL NSW
NOTES
ABBREVIATIONSCOLCOSDPELECEXFCLFFLFHFHRFRLFSFWHYDENGDWG
COLUMNCHECK ON SITE
DOWNPIPEELECTRICAL
EXISTINGFINISHED CEILING LEVELFINISHED FLOOR LEVEL
FIRE HYDRANTFIRE HOSE REEL
FIRE RESISTANCE LEVELFIRE STAIR
FLOOR WASTEHYDRAULICENGINEERS
DRAWINGS + SPECS
MECHMINMAXNOMRLRWOSIMSPECSSLTBCTOWTYPU/SSTRUC
MECHANICALMINIMUM
MAXIMUMNOMINAL
RELATIVE LEVELRAIN WATER OUTLET
SIMILARSPECIFICATION
STRUCTURAL SLAB LEVELTO BE CONFIRMED
TOP OF WALLTYPICAL
UNDERSIDESTRUCTURAL
1. THIS DRAWING IS ISSUED UPON THE CONDITION IT IS NOT COPIED,REPRODUCED, RETAINED OR DISCLOSED TO ANY UNAUTHORISED PERSONEITHER WHOLLY OR IN PART WITHOUT PRIOR CONSENT IN WRITING OFfitzpatrick+partners.
2. DRAWINGS SHOW DESIGN INTENT ONLY. SHOP DRAWINGS ARE TO BEPROVIDED FOR APPROVAL PRIOR TO CONSTRUCTION OR MANUFACTURE.
3. DO NOT SCALE DRAWINGS. CHECK DIMENSIONS BEFORE COMMENCINGWORK.
4. INCONSISTENCIES ARE TO BE REPORTED TO fitzpatrick+partners.
5. NUMBERS FOLLOWING AN ABBREVIATION DENOTE A PARTICULAR TYPE OFITEM. FOR EXPLANATION OF ITEM TYPES REFER TO SPECIFICATION ANDFINISHES SCHEDULE.
6. CONSULTANT DETAILS ARE INCLUDED FOR EASE OF REFERENCE ONLY.
7. ALL DRAWINGS TO BE PRINTED IN COLOUR.
MSCP CONTRACTOR
LEVEL 5/9 -13 CASTLEREAGH ST, SYDNEY NSW 2000
STRUCTURAL / CIVIL
LEVEL 3/48 CHANDOS ST, ST LEONARDS NSW 2065
MECHANICAL / ELECTRICAL / SECURITY
HYDRAULIC / FIRE
LEVEL 9/233 CASTLEREAGH ST, SYDNEY NSW 2000
LEVEL 4/99 WALKER ST, NORTH SYDNEY NSW 2060
LANDSCAPE ARCHITECT
65-69 KENT ST, SYDNEY NSW 2000
2180
7 LH
AP M
SCP
DD
-05
KEY PLAN
218071:200@A1STATUS
CONSTRUCTIONDOCUMENTATION
APPROVEDRP
DRAWNAB
PRINT DATE1/12/2020
ISSUEDRAWING NO.10LHAP-AR-FPA-DRG-CP-110102
PROJECT MANAGER
LEVEL 2, 7-9 WEST STREET, NORTH SYDNEY, NSW 2060
GENERAL NOTES1. DRAWINGS TO BE READ IN CONJUNCTION WITH ALL DOCUMENTATION PROVIDED.2. DRAWINGS TO BE READ IN CONJUNCTION WITH ALL SPECIALIST ENGINEERING CONSULTANT DOCUMENTATION. ALL ENGINEERING INFORMATION SHOWN IN THE ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY.3. FOR ALL EXTERNAL AREAS REFER TO CIVIL / LANDSCAPE DRAWINGS.4. ALL CONCRETE FINISH TO BE CLASS 2 UNO [SHARP CORNER EDGES].5. FOR BUILDING ROOF SAFETY PLEASE REFER TO FINISHES SCHEDULE.6. FIBRE CEMENT SHEETING TO ALL WET AREAS.7. DENOTES WALLS THAT REQUIRE TO BE FIRE RATED. REFER TO BCA FOR FIRE RESISTANCE REQUIREMENTS.
6.61 %
BRAIN INJURY
FHR
BO01
LOW CLEARANCECAR SPACES
(WARNING REQUIRED)
52,368.6 mm52,985 mm
2320001
2320002
3320004
1320005
1130001
10,800 10,800 10,800 10,800 10,800 10,800 10,800 10,800 10,800 10,800 11,400 5,050
8,30
08,
700
8,30
028
,700
10,800 10,800 10,800 10,800 10,800 10,800 10,800 10,800 10,800 10,800 11,400 5,050
2120002
OUTLINE OF BRIDGE LINK ABOVE
BO01
BO01
FHR
FHR
DCS DCS
BO01
FE
FE
FE
BO01BO01
BO01BO01
FE
FHRFED03B
L1A
D03AL1A
D04BL1A
D04AL1A
D01BL1A
D05L1A
D01AL1A
FH
PA13 TO ALL CAR SPACES LINE MARKINGS
WS0
1
WS0
1W
S01
WS0
1
SC
SC
SC SCSCSC
SCSCSC
SC
SC
SC
SC
SC SC
SC SCSC SC SC SC
SC
WT1
01
WT101
WT101
WT1
01
WT101
WT1
01
WT2
02
WT1
01
WT1
01
WT1
01
CO02
CO02
CO02CO02
CO02
CO02 CO02
BK03
CO02
CO02
CO02
BR01
BR01
BR03BR03BR03
BR01
BR03
CO02
CO05 CO05 CO05 CO05
CO05
CO05
CO05
CO05 CO05 CO05
CO05
CO04
WS0
1
FX06
FX06
SC
WT403B
OUTLINE OF SLAB ABOVE
FX03
CD01-05
CD01-05
CD01-05
CD01B TO PERIMETER OFUPSTAND OF SPIRAL RAMPUNDER REVIEW
CO03
CO04
CO05 CO05
CO05
CO05
COVERED WALKWAY TYPE 1 & 2PART OF THE MSCP SCOPE.REFER TO DWG LHAP-AR-FPA-DRG-CP-670001 FOR DETAILS
COVERED WALKWAYTYPE 3 & 4 NOT PARTOF THE MSCP SCOPE.REFER TO DWG LHAP-AR-FPA-DRG-CP-670001 FOR DETAILS
DP
CD01, TO SEMICIRCLE VOID
TGSI 01
SC SC SC
FX06
FX06
PA11
, KE
RB
CD01
BR03
PA11
KER
B
PA11
KER
B
BO01 BO01FHR, FH
FH
FX01
BR02
BR02
CO05
FX13
FH FH
LV01, HIGH LEVEL
CO02
RAMP WIDTH SUBJECT TOFINALIZATION OF ANTI-CLIMBABLEBARRIER DESIGN
WS0
1W
S01
WS0
1
CD01 EXTENSIONFROM GF TO LEVEL 1[COVERING BLOCK WALL]& CONCRETE UPSTAND
1:8 UP TO LEVEL 2A
1:8 UP TO LEVEL 1B
UP
DOWN
DOWN
UPfrom belowEX
ISTIN
G P
2 O
UTLI
NE
[to
be d
emol
ished
afte
r MSC
P co
mpl
etio
n]
LIFT 45 LIFT 46
UPPER DECK FALLS TONORTHERN SLAB EDGE
LOWER DECK FALLS TOSOUTHERN SLAB EDGE
74 CARS
70 CARS
BRAIN INJURY
DOWN
UP
RAMP 1:8 MAX AT INSIDEFACE OF INNER KERB UNO
LIFT 44
CO05 TO ALLEXPOSED COLUMNS
LINEMARKINGSEPARATION
SSL +14.750
SSL +13.550
FX03FX03
FX03
FX03
FX03
FX03
FLOW ARROWS INDICATIVE ONLYREFER TO TRAFFIC DWGs FOR DETAILS
FLOW ARROWS INDICATIVE ONLYREFER TO TRAFFIC DWGs FOR DETAILS
L1-01BLEVEL 1BCO01
L1-01ALEVEL 1ACO01
1120002
CY
CW
CX
CZ
CA
CB
CC
CD
C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13
D01CL1A
DP FX01 DP FX01DP FX01DP FX01DP FX01DP FX01DP FX01DP FX01DP FX01DP FX01
DP FX01FX01 DP FX01 DP FX01 DP FX01 DP FX01 DP FX01 DP FX01 DP FX01 DP FX01 DP FX01
WT101WT1
01
WT1
01 WT1
01
CO02
CO05DP FX01
CRDP FX01 DP
DP FX01FE
FHRFE
DP
DP
LV01, HIGH LEVEL
LV01, ABOVE DOOR
WS0
1
NEWCOVEREDWALKWAY
LOT BOUNDARY
RAMP 1:8 MAXAT INSIDE FACEOF INNER KERB
RAMP 03
RAMP 04
RAMP 02
RAMP 01
L1-03STAIR 01
L1-04STAIR 02
L1-05COMMS
COMMS
ELEC ELEC
2120001
PARKING NUMBERSON-GRADE
GROUND LEVEL
LEVEL 1A+1B
66 (17 SC / 11 ACC / 0 MB)
94 (19 SC / 12 ACC / 0 MB)
144 (26 SC / 0 ACC / 0MB)
<< NOT PART OF THE MSCP SCOPE