Page 1: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

WELCOME

Page 2: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

PARAMETRIC STUDIES ON AUTOMOTIVE RADIATORS

PRESENTED BYJACKSON JOHNY

Roll No:127

GUIDED BYMr. SUMESH C.K

Assistant professor

SREE CHITRA THIRUNAL COLLEGE OF ENGINEERING TVM-18

Page 3: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

CONTENTS

1. INTRODUCTION

2. NECESSITY OF COOLING

3. TYPES OF RADIATOR

4. GEOMETRY DESCRIPTION

5. WORKING CONDITION

1/26

Page 4: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

6. PARAMETRIC STUDIES ON RADIATOR

AIR AND COOLANT MASS FLOW

INFERENCE

AIR INLET TEMPERATURE INFLUENCE

COOLANT FLUID INFUENCE

FIN PITCH INFLUENCE

LOUVER ANGLE INFERENCE

COOLANT FLOW LAYOUT INFLUENCE

7. CONCLUSION

8. REFERENCE2/26

Page 5: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

An important role in its weight and also in the design of its front-end module.

The automotive industry is continuously involved in a strong competitive career to obtain the best automobile design in multiple aspects.

An experimental testing on two radiators of the same flow area but with the tubes in vertical or horizontal position.

INTRODUCTION

3/26

Page 6: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

There are two type of automotive radiator.o Down flow type.o Cross flow type. Parameters radiator are:o Air flowo Coolant flowo Materialo Size

4/26

Page 7: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

Necessity of cooling IC engine

To keep the engine at its most efficient operating

temperature.

To control the pollution.

Safe guard the engine parts.

Higher the fuel efficiency.

To avoid excess engine oil consumption.

5/26

Page 8: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

Types of automotive radiators

Down flow radiator type

6/26

Page 9: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

Cross flow radiator type

• Advantage :Lower styling

profile.Reduce

pressure.Efficient cooling

7/26

Page 10: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

Geometry description of the automobile radiator under study

Core depth (mm) :23 Core height (mm) :133 Core length (mm) :184 Circuiting (passes) :I Rows (no) :1 Total tubes (no) :12 Tube dimensions (mm) :22 *2.1 Tube thickness (mm) :0.32 Tube pitch (mm) :10.40 Fin pitch (mm) :1.19 Fin thickness (mm) :0.1 Louver angle (O) :26 Louver pitch (mm) :0.9 8/26

Page 11: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

working conditions for the automobile radiator under study

Air inlet temperature (C) :25

Air inlet humidity (%) :50

Air mass flow (kg/s) :0.08/0.14/0.21/0.28/0.40

Coolant fluid :Water/ethylene glycol (50%)

Coolant inlet temperature (C) :95.0

Coolant mass flow (kg/h) :500/1000/1500/2000/2500

9/26

Page 12: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

Parametric studiesAir and coolant mass flow influence

10/26

Page 13: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

Performance maps obtained for a parametric study (fin pitch, Fp, in this case). On the left, heat transfer dependence on air and coolant flow rates. On the right, overall enhancement vs. air and coolant flow .

11/26

Page 14: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

• The heat transfer and fluid-dynamic performance of an automotive radiator is strongly dependent on both thermal fluids mass flow.

• Cooling capacity increases with both air and coolant flow.

• Pressure drop on mass flow.

12/26

Page 15: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

AIR INLET TEMPERATURE INFLUENCE

The maximum coolant flow (2500 kg/h)has been selected. The temperature ranges from 0to40C. Heat transfer decreases with air inlet temperature raises.

13/26

Page 16: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

Coolant fluid influence

The selection of a particular coolant fluid is

depend on the environmental conditions of

certain country.

The radiator is analysed working with seven

different thermal fluids: water,

ethylene glycol,and propylene glycol

14/26

Page 17: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

The impact on the cooling capacity and the overall heat transfer coefficient is notable.

while ethylene glycol and propylene glycol report similar values for the same water content little impact on the overall coolant pressure drop

15/26

Page 18: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

Fin pitch influence

16/26

Page 19: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

Fin pitch is one of the most important design

parameters in this kind of heat exchangers. Fin pitches from 0.6 to 2.4 mm have been considered.

UA has been taken as the enhancement parameter.

smaller fin spacing imply higher heat transfer

capacity and air pressure drop at fixed air flow rate.

High coolant flow is provided.

17/26

Page 20: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

Louver angle influence

18/26

Page 21: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

The heat transfer enhancement mechanisms involved in a louvered automotive radiator.

Louver angle varies from 15 to35 degrees. Best design solution could

depend on the need of compactness and available pumping power.

19/26

Page 22: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

Coolant flow lay-out influence

20/26

Page 23: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

The proposed radiator has been studied under five liquid flow arrangements: 1 pass (I), 2 passes (U), 2 passes with bypass of different diameters: 3, 5 and 7 mm (Uby-3,Uby-5, Uby-7).

21/26

Page 24: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

2 pass increase cooling capacity. Design can be carried out by the with help

of pumping power.

22/26

Page 25: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

Conclusions

Parametric study on automotive radiator

help to design high performance radiator. Performance of cooling system increases

with increase in coolant circulation. Heat exchange rate depend on the

temperature gradient between radiator temperature and inlet air temperature.

Better coolant can increase cooling capacity.

23/26

Page 26: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

REFERENCEC. Oliet, A. Oliva *, J. Castro, C.D. Pe´rez-Segarra,Parametric

studies on automotive radiators, Centre Tecnolo` gic de Transfere`ncia de Calor (CTTC), Universitat Polite`cnica de Catalunya (UPC), ETSEIAT,

Colom 11, 08222 Terrassa (Barcelona), Spain. C. Lin, J. Saunders, S. Watkins, The effect of changes in ambient

and coolant radiator inlet temperatures and coolant flowrate on specific dissipation, SAE Technical Paper Series (2000-01-0579), 2000.

24/26

Page 27: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

J.J. Juger, R.F. Crook, Heat transfer performance of propylene glycol versus ethylene glycol coolant solutions in laboratory testing, SAE Technical Paper Series SP-1456, 1999-01-0129,

M. Gollin, D. Bjork, Comparative performance of ethylene glycol/ water and propylene glycol/water coolants in automobile radiators,SAE Technical Paper Series SP-1175, 960372, 1996, pp. 115–123.

Dr.Kripal Singh,automobile engineering,vol-2. www.howautowork.com

25/26

Page 28: PARAMETRIC STUDES ON AUTOMOTIVE RADIATOR

26/26

TANK YOU