  • Product Weight

    Weight

    0.157” (4mm) 1.50 Ib/ft² [7.3 kg/m²]

    Panel Sizes

    Dimensions

    Width 40”, 49.2”, 62” (1020mm, 1250mm. 1574mm)Custom: up to 78.74” (2000mm)

    Length 122”, 146”, 196” (3099mm, 3708mm, 4980mm)Custom: up to 256” (6502mm)

    Product Tolerances

    Product Composition

    Width ± 0.079” (2mm)

    Length ± 0.157” (4mm)

    Thickness ± 2%

    Bow Max 0.5% of length and/or width

    Squareness Max 0.196” (4.97mm)

    Surface Defects The surface shall not have any irregularities such as dents, scratches and other imperfections in accordance with our 3rd party verified QC program assurance.

    2 | Vitrabond | Technical Manual

    z Peel off Protective Film

    z Clear Coating Finish Dependent

    z PVDF Coloured Coating

    z Primer Coating

    z 0.5mm Aluminum Skin

    z 3mm Fire Retardant

    z 0.5mm Aluminum Skin

    z Chromate Conversion Coating

    TYPICAL COMPOSITION

  • Standards Description Test Standard Result

    PROPERTIES

    ASTM E136 Fire Performance of 3003 Aluminum T< 86°F PASS

    ASTM C393 Core Shear Ultimate Stress >150 psi [1.03 MPa] (Test Specimen Average) PASS

    ASTM C393 Flexure Stress >15695 psi [108.21 MPa] (Test Specimen Average) PASS

    IMPACT RESISTANCE

    ANSI FM4473 Severe Hail Exposure Test PASS/FAIL PASS

    THERMAL PERFORMANCE

    ASTM D696 Coefficient of Linear Expansion 13.8x10^-6 in/in°F

    BOND INTEGRITY

    ASTM C297 Flatwise Tensile Strength >400 psi [2.76 MPa] PASS

    ASTM D1781 Climbing Drum Peel Test >22.5 in-Ib/in [100 mm-N/mm] PASS

    ASTM D1002 Peak Shear Strength >515 psi [3.55 MPa] PASS

    FIRE PERFORMANCE

    ASTM E84 Flame Spread

  • PVDF Coating Descriptions Test Test Result

    ASTM B117 Salt Spray Resistance 5% salt fog at 95°FPasses 4000 hrs. Less than 1/16” avg creepage from scribe. None or few #8 blisters

    ASTM D523 Specular Gloss Test Standard @ 60° Varies per finish

    ASTM D1308 Alkali Test 10%, 25% NaOH, 1hr No Effect

    ASTM D714 Blistering of Paint Test 100% Relative Humidity @ 95°F Passes 4000 hrs.

    ASTM D2244 Exterior Exposure 10 years @ 45° South Florida PASS - Max. 5 fade

    ASTM D2247 Water Resistance 100% Relative Humidity @ 95°F No #8 blisters

    ASTM D2794 Reverse Impact 1.5 x metal thickness (Aluminum) No cracking or adhesion loss

    ASTM D3359 Adhesion Reverse impact 1/16” crosshatch No adhesion loss

    ASTM D3363 Film Hardness Pencil Test F - 2H PASS

    ASTM D4145 Prepainted Metal Coating Flexibility T - Bend 0 - 2 T - Bend, No pick off

    ASTM D4214 Chalk Resistance 10 years @ 45° South Florida Pass - Max. 8 Chalk

    Technical Data – AMMA 2605 Standard PVDF Coating

    Quality ControlOur dedication to fulfilling our customer’s expectations is reflected in our superior quality control system, beginning at the point of specification and continuing through to delivery of our guaranteed products. All activities are carried out in a manner that:

    z Uses the framework of ISO9000 Quality Standards to verify the quality of our systems

    z Ensures that our products and services are of the highest standards z Create continuous improvements to our product through the

    application of the best quality practices.

    4 | Vitrabond | Technical Manual

  • AAMA 508 PRESSURE EQUALIZED ARROWHEAD RAIN SCREEN

    Standard Test Test Standard Result

    ASTM E283 Air Leakage of Test Buck (without panel system installed)0.11 cfm/ft² min. 0.13 cfm/ft² max. PASS

    ASTM E1233 Cyclic Static Air Pressure Differential (pressure cycling)Cycle Time Lag 0.08 sec max. Cycle Pressure Difference 12.5 psf max.

    PASS

    PASS

    ASTM E331 Static Water Penetration 3.20 ft² PASS

    AAMA 501.1 Dynamic Water Penetration 3.20 ft² PASS

    ASTM E330 Uniform Load Deflection and Uniform Load Structural L/175 of Stiffener Length PASS

    Warranty

    AAMA 509 DRAINED AND BACK VENTILATED ARROWHEAD RAIN SCREEN

    Standard Test Lean Results Flex Results

    ASTM E283 Air Leakage V1 V3

    ASTM E331 Static Water PenetrationW1 W1

    AAMA 501.1Dynamic Water Penetration

    VITRABOND FR PANEL OVER ARROWHEAD

    Standard Test Test Results Results

    TAS 202 - 94Uniform Static Air Pressure

    (+100/-150 psf) PASS

    TAS 201 - 94Large Missile Impact Procedures

    (+100/-150 psf) PASS

    TAS 203 - 94Cyclic Winds Pressure Loading

    (+100/-150 psf) PASS

    Complies to AAMA 508 and 509 when installed with Arrowhead and meets the test protocols TAS201, 202, and 203 in accordance with the Florida building code for the high velocity hurricane zone and Miami Dade County requirements.

    System-Tested Solutions

    Vitrabond | Technical Manual | 5

    A product warranty of up 20 years is provided when installed by a licenced installer. An MCM coating warranty is issued on a project specific basis and is available up to 30 years per Fairview architectural approval.

  • It is the responsibility of the Architect, Building Owner, General Contractor, Installer or Fabricator to ensure that the appropriate tests have been

    carried out on the final assembly and that the materials meet the national, regional and local building codes and regulations. As the supplier, Fairview

    can only offer test reports for Vitrabond and any tested wall assembly. Fairview is not responsible for determining if a variation in the wall

    assembly will meet the test standards.

    Technical Data contained in this document is accurate at the time of writing 01/01/2020. In the event more information is required please

    contact the Fairview office on 860-242-2711 or email: [email protected]

    Project: The Parker, Alexandria, VA Issue - 2.0