panel sizes - fairview architectural north america · 2020. 10. 19. · astm d4214 chalk resistance...
TRANSCRIPT
-
Product Weight
Weight
0.157” (4mm) 1.50 Ib/ft² [7.3 kg/m²]
Panel Sizes
Dimensions
Width 40”, 49.2”, 62” (1020mm, 1250mm. 1574mm)Custom: up to 78.74” (2000mm)
Length 122”, 146”, 196” (3099mm, 3708mm, 4980mm)Custom: up to 256” (6502mm)
Product Tolerances
Product Composition
Width ± 0.079” (2mm)
Length ± 0.157” (4mm)
Thickness ± 2%
Bow Max 0.5% of length and/or width
Squareness Max 0.196” (4.97mm)
Surface Defects The surface shall not have any irregularities such as dents, scratches and other imperfections in accordance with our 3rd party verified QC program assurance.
2 | Vitrabond | Technical Manual
z Peel off Protective Film
z Clear Coating Finish Dependent
z PVDF Coloured Coating
z Primer Coating
z 0.5mm Aluminum Skin
z 3mm Fire Retardant
z 0.5mm Aluminum Skin
z Chromate Conversion Coating
TYPICAL COMPOSITION
-
Standards Description Test Standard Result
PROPERTIES
ASTM E136 Fire Performance of 3003 Aluminum T< 86°F PASS
ASTM C393 Core Shear Ultimate Stress >150 psi [1.03 MPa] (Test Specimen Average) PASS
ASTM C393 Flexure Stress >15695 psi [108.21 MPa] (Test Specimen Average) PASS
IMPACT RESISTANCE
ANSI FM4473 Severe Hail Exposure Test PASS/FAIL PASS
THERMAL PERFORMANCE
ASTM D696 Coefficient of Linear Expansion 13.8x10^-6 in/in°F
BOND INTEGRITY
ASTM C297 Flatwise Tensile Strength >400 psi [2.76 MPa] PASS
ASTM D1781 Climbing Drum Peel Test >22.5 in-Ib/in [100 mm-N/mm] PASS
ASTM D1002 Peak Shear Strength >515 psi [3.55 MPa] PASS
FIRE PERFORMANCE
ASTM E84 Flame Spread
-
PVDF Coating Descriptions Test Test Result
ASTM B117 Salt Spray Resistance 5% salt fog at 95°FPasses 4000 hrs. Less than 1/16” avg creepage from scribe. None or few #8 blisters
ASTM D523 Specular Gloss Test Standard @ 60° Varies per finish
ASTM D1308 Alkali Test 10%, 25% NaOH, 1hr No Effect
ASTM D714 Blistering of Paint Test 100% Relative Humidity @ 95°F Passes 4000 hrs.
ASTM D2244 Exterior Exposure 10 years @ 45° South Florida PASS - Max. 5 fade
ASTM D2247 Water Resistance 100% Relative Humidity @ 95°F No #8 blisters
ASTM D2794 Reverse Impact 1.5 x metal thickness (Aluminum) No cracking or adhesion loss
ASTM D3359 Adhesion Reverse impact 1/16” crosshatch No adhesion loss
ASTM D3363 Film Hardness Pencil Test F - 2H PASS
ASTM D4145 Prepainted Metal Coating Flexibility T - Bend 0 - 2 T - Bend, No pick off
ASTM D4214 Chalk Resistance 10 years @ 45° South Florida Pass - Max. 8 Chalk
Technical Data – AMMA 2605 Standard PVDF Coating
Quality ControlOur dedication to fulfilling our customer’s expectations is reflected in our superior quality control system, beginning at the point of specification and continuing through to delivery of our guaranteed products. All activities are carried out in a manner that:
z Uses the framework of ISO9000 Quality Standards to verify the quality of our systems
z Ensures that our products and services are of the highest standards z Create continuous improvements to our product through the
application of the best quality practices.
4 | Vitrabond | Technical Manual
-
AAMA 508 PRESSURE EQUALIZED ARROWHEAD RAIN SCREEN
Standard Test Test Standard Result
ASTM E283 Air Leakage of Test Buck (without panel system installed)0.11 cfm/ft² min. 0.13 cfm/ft² max. PASS
ASTM E1233 Cyclic Static Air Pressure Differential (pressure cycling)Cycle Time Lag 0.08 sec max. Cycle Pressure Difference 12.5 psf max.
PASS
PASS
ASTM E331 Static Water Penetration 3.20 ft² PASS
AAMA 501.1 Dynamic Water Penetration 3.20 ft² PASS
ASTM E330 Uniform Load Deflection and Uniform Load Structural L/175 of Stiffener Length PASS
Warranty
AAMA 509 DRAINED AND BACK VENTILATED ARROWHEAD RAIN SCREEN
Standard Test Lean Results Flex Results
ASTM E283 Air Leakage V1 V3
ASTM E331 Static Water PenetrationW1 W1
AAMA 501.1Dynamic Water Penetration
VITRABOND FR PANEL OVER ARROWHEAD
Standard Test Test Results Results
TAS 202 - 94Uniform Static Air Pressure
(+100/-150 psf) PASS
TAS 201 - 94Large Missile Impact Procedures
(+100/-150 psf) PASS
TAS 203 - 94Cyclic Winds Pressure Loading
(+100/-150 psf) PASS
Complies to AAMA 508 and 509 when installed with Arrowhead and meets the test protocols TAS201, 202, and 203 in accordance with the Florida building code for the high velocity hurricane zone and Miami Dade County requirements.
System-Tested Solutions
Vitrabond | Technical Manual | 5
A product warranty of up 20 years is provided when installed by a licenced installer. An MCM coating warranty is issued on a project specific basis and is available up to 30 years per Fairview architectural approval.
-
It is the responsibility of the Architect, Building Owner, General Contractor, Installer or Fabricator to ensure that the appropriate tests have been
carried out on the final assembly and that the materials meet the national, regional and local building codes and regulations. As the supplier, Fairview
can only offer test reports for Vitrabond and any tested wall assembly. Fairview is not responsible for determining if a variation in the wall
assembly will meet the test standards.
Technical Data contained in this document is accurate at the time of writing 01/01/2020. In the event more information is required please
contact the Fairview office on 860-242-2711 or email: [email protected]
Project: The Parker, Alexandria, VA Issue - 2.0