1
length = 400 mm Data wires should be twisted pair. 15 twists/meter Installation 5030124 Wiring diagram Publ.no: M5030124A Ed. D Green 12 DATA + White 13 DATA - Black 29 GND (-VREF)* CABLE - USB Type B female / (PANEL) Ordering part no.: 5030124 IQAN-MC2 or IQAN-MD3 CABLE - USB Type A male to Type B male connection available from computer cable supplier 29 15 1 5030124 MC2 wire pos. signal name 42 28 14 To PC units in mm Panel mounting hole dimensions * Do not connect GND to pos. 15 (-BAT). 19,4 ±0,1 Ø20,8 ±0,1 Green C2:7 DATA + White C2:6 DATA - Black C2:5 GND (-VREF)* 5030124 MD3 wire pos. signal name * Do not connect GND to pos. C1:1 (-BAT). 5 4 3 2 1 12 11 10 9 8 7 6 11 10 9 8 7 6 5 4 3 2 1 12 C1 C2 USB isolation device WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application, including consequences of any failure, and review the information concerning the product or system in the current product catalogue. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice. CAUTION Do not connect the module directly to the USB port of your computer. Possible “ground loops” can damage your PC or the module. A USB isolation device is recommended to safely connect your PC to the module. 1 6 12 7

Upload: john-evans

Post on 24-Nov-2015

12 views

Category:

Documents


0 download

TRANSCRIPT

  • length = 400 mm Data wires should be twisted pair.15 twists/meter

    Installation 5030124Wiring diagram Publ.no: M5030124A Ed. D

    Green 12 DATA +White 13 DATA -Black 29 GND (-VREF)*

    CABLE - USB Type B female / (PANEL)Ordering part no.: 5030124

    IQAN-MC2 or IQAN-MD3

    CABLE - USB Type A male to Type B male connectionavailable from computer cable supplier

    29151

    5030124 MC2 wire pos. signal name

    422814

    To PC

    units in mm

    Panel mounting hole dimensions

    * Do not connect GND to pos. 15 (-BAT).

    19,4 0,1

    20,8 0,1

    Green C2:7 DATA +White C2:6 DATA -Black C2:5 GND (-VREF)*

    5030124 MD3wire pos. signal name

    * Do not connect GND to pos. C1:1 (-BAT).

    54

    32

    11211

    109

    87 6

    1110

    98

    7 65

    43

    2112

    C1C2

    USB isolation device

    WARNINGFAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application, including consequences of any failure, and review the information concerning the product or system in the current product catalogue. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met.

    The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.

    CAUTION Do not connect the module directly to the USB port of your computer.

    Possible ground loops can damage your PC or the module.A USB isolation device is recommended to safely connect your PC to the module.