page 1 of 11 fitting rooms - single & double asy1-300fitting rooms - single & double...

11
A S Y 1 -3 0 0 FITTING ROOMS - SINGLE & DOUBLE PAGE 1 OF 11 INSTALLATION INSTRUCTIONS P.O. BOX 729 / TERRELL, TEXAS 75160 / 972.563.5744 / 800.776.2349 P.O. BOX 177 / GOODWATER, ALABAMA 35072 / 205.839.6354 / 800.633.6282 REV# ECN# REVISION BY DATE 5 0 / 8 1 / 8 B J A 6 8 9 3 L 5*3816 CAB 08/21/07 ADDED PART CODES TO THE ASY 01 A REV# ECN# REVISION BY DATE REV 01 DRICF DRDPS DRTRS DPS SPLICER DRDPR-LH DOOR PANEL RETAINER DRDP-60 DOOR PANEL DROA & DRIA FLOOR ANCHOR DROCF OBS KP-48 KICK PLATE TLEG-16 -4 SL-4 OBS-5 MEBP-4830 BXHL-424 MEBP-4830 MEBP-4836 BH-436 BXH-430 BXH-430 DRDPR-RH STL-5 STL-4 SS-4 STL-5 DRUFC EU-24 SS-5 BU-96 HARDWARE DRHPH SINGLE ROOM

Upload: others

Post on 13-Jun-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas

ASY1-300FITTING ROOMS - SINGLE & DOUBLEPAGE 1 OF 11

I N S T A L L A T I O N I N S T R U C T I O N S

P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2

REV# ECN# REVISION BY DATE50/81/8BJA6893L

5*3816 CAB 08/21/07ADDED PART CODES TO THE ASY01A

REV# ECN# REVISION BY DATE

REV01

DRICFDRDPSDRTRS

DPSSPLICER

DRDPR-LHDOOR PANELRETAINER

DRDP-60DOORPANEL

DROA & DRIAFLOOR ANCHOR

DROCF

OBS KP-48KICK PLATE

TLEG-16

-4

SL-4

OBS-5

MEBP-4830

BXHL-424

MEBP-4830

MEBP-4836BH-436

BXH-430

BXH-430

DRDPR-RH

STL-5

STL-4

SS-4

STL-5

DRUFC

EU-24

SS-5

BU-96

HARDWAREDRHPH

SINGLEROOM

Page 2: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas

ASY1-300FITTING ROOMS - SINGLE & DOUBLEPAGE 2 OF 11

I N S T A L L A T I O N I N S T R U C T I O N S

P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2

REV01

EU-24

DRICFDRDPSDRP

DRTRS DRPRPANEL RETAINER

DPSSPLICER

DRDPR-LHDOOR PANELRETAINER

DRDP-60DOOR PANEL

DROA & DRIAFLOOR ANCHOR

DROCF

MEBP-4830

MEBP-4830

MEBP-4836BH-436

BXH-430

STL-5

STL-5

STL-4

SS-4

SS-5

OBS-5

SL-4

DRDPSS

TLEG-16

-4

BU-96

DRDPR-RH

HARDWAREDRHPD

DOUBLEROOM

Page 3: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas

ASY1-300FITTING ROOMS - SINGLE & DOUBLEPAGE 3 OF 12

I N S T A L L A T I O N I N S T R U C T I O N S

P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2

REV01

Lay out accurate chalklines on the floor forlocation of uprights as shown at right. Singlefitting room and double fitting room usesame dimensions.

1

Build perimeter walls as shown at right.Note location of TLEG shoes. Double fittingroom is shown.

2UPRIGHT

Page 4: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas

ASY1-300FITTING ROOMS - SINGLE & DOUBLE PAGE 4 OF 11

I N S T A L L A T I O N I N S T R U C T I O N S

P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2

REV01

Side wall sections for both single & doublefitting rooms use same components. Metalpanels go to outside. Silver laminate goes tooutside for extension panels.

3

EU-24

BU-96

Page 5: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas

ASY1-300FITTING ROOMS - SINGLE & DOUBLE PAGE 5 OF 11

I N S T A L L A T I O N I N S T R U C T I O N S

P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2

REV01

Retainer pins MUST be installed in TLEGshoes. Install standard base shoes tem-porarliy to stablize walls until corners arebuilt. Engage lock clip on base shoes.Once walls are joined for corners, retractlock clips and remove base shoes straightout.

4

OBSOPEN BACK STIFFNERS BOLT TO UPRIGHTS

OBS bolts to uprights. Lower spannersinstall just above OBS. Continue up withMetal Backs and splicer spanners. Installtop caps at top. Do not install extensionsat this time.

5

Page 6: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas

ASY1-300FITTING ROOMS - SINGLE & DOUBLE PAGE 6 OF 11

I N S T A L L A T I O N I N S T R U C T I O N S

P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2

REV 01

After side walls are built, stand corneruprights (no shoes) at 90° and installspacers into lances. Four per corner.

6

DRUS, SPACER

NOTE:FOR SINGLE ROOMS...SET HANDICAP BENCH IN PLACE ANDCONSTRUCT WALLS AROUND BENCH -BENCH IS TOO LARGE TO SET IN PLACEAFTER ROOM IS CONSTRUCTED. BENCHSECURES TO REAR PANELS WITH DRY-WALL SCREWS. WAIT UNTIL LAST STEPTO SECURE BENCH!

SECURE BENCHAFTER WALLSBUILT

DRHB & DRCB

Page 7: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas

ASY1-300FITTING ROOMS - SINGLE & DOUBLE PAGE 7 OF 11

I N S T A L L A T I O N I N S T R U C T I O N S

P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2

REV 01

FOR DOUBLE FITTING ROOMS...Install LH & RH divider panel retainers intomiddle uprights on interior of walls. Tabsengage upright slots.

7

Locate lower divider panel in placebetween retainers and resting on floor.Run screws into panel through retainers.Locate splicer on top of lower panel andinstall upper panel. Secure splicer andupper panel with screws.

8

DRDPSSSPLICER

DRPR

DRPR

Page 8: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas

ASY1-300FITTING ROOMS - SINGLE & DOUBLE PAGE 8 OF 11

I N S T A L L A T I O N I N S T R U C T I O N S

P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2

REV 01

Install upright extensions and tightenexpansion screws as shown.

9

Install corner spacers (2) for each cor-ner.

10Install extension backs and top span-

ners.11

Slide outside corner covers into place.Covers are retained between the uprightedges and the spacers.

12COVER IN PLACE

DRUS

DROCF

Page 9: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas

ASY1-300FITTING ROOMS - SINGLE & DOUBLE PAGE 9 OF 11

I N S T A L L A T I O N I N S T R U C T I O N S

P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2

REV 01

1/4-20 x 1”SCREW

Install upright inserts (6) into side wallupright tops until they catch in lances

and can not be pulled out.

13

Install wall stabilizer rails over walllength, covering spanners and uprights.Use the provided 1” screws to securestabilizers to inserts. Only install outside

screws at this time.

14

Install middle stabilizer on both singleand double rooms. Secure with samescrews that hold wall stabilizers to mid-dle upright inserts.

15 1/4-20 x 1”SCREW

Page 10: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas

ASY1-300FITTING ROOMS - SINGLE & DOUBLE PAGE 10 OF 11

I N S T A L L A T I O N I N S T R U C T I O N S

P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2

REV 01

Install trim to interior faces of uprightsusing plactic fasteners as shown.

16 NOTE: IT IS RECOMMENDED THAT ALL VERTICALAND HORIZONTAL SEAMS BE CAULKED WITHCLEAR SILICONE FOR SECURITY AND THEFT

PEVENTION!

Position benches in rooms as shown.1

DRCB,

DRCB,

DRHB,

DRICFDRICF

Page 11: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas

ASY1-300FITTING ROOMS - SINGLE & DOUBLE PAGE 11 OF 11

I N S T A L L A T I O N I N S T R U C T I O N S

P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2

REV 01

Door panels ate stabilized at bottomwith floor anchors, as indicated by starsay right (DOUBLE room is shown - SIN-GLE only takes (2) anchors on doorside) Rough opening width is 38 3/4”.Install the anchors adjacent to the doorcasing as shown. Install anchorsAFTER the door units are in place.

17

DRIA,

DROA,