page 1 of 11 fitting rooms - single & double asy1-300fitting rooms - single & double...
TRANSCRIPT
![Page 1: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas](https://reader035.vdocuments.us/reader035/viewer/2022070807/5f0657937e708231d4178342/html5/thumbnails/1.jpg)
ASY1-300FITTING ROOMS - SINGLE & DOUBLEPAGE 1 OF 11
I N S T A L L A T I O N I N S T R U C T I O N S
P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2
REV# ECN# REVISION BY DATE50/81/8BJA6893L
5*3816 CAB 08/21/07ADDED PART CODES TO THE ASY01A
REV# ECN# REVISION BY DATE
REV01
DRICFDRDPSDRTRS
DPSSPLICER
DRDPR-LHDOOR PANELRETAINER
DRDP-60DOORPANEL
DROA & DRIAFLOOR ANCHOR
DROCF
OBS KP-48KICK PLATE
TLEG-16
-4
SL-4
OBS-5
MEBP-4830
BXHL-424
MEBP-4830
MEBP-4836BH-436
BXH-430
BXH-430
DRDPR-RH
STL-5
STL-4
SS-4
STL-5
DRUFC
EU-24
SS-5
BU-96
HARDWAREDRHPH
SINGLEROOM
![Page 2: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas](https://reader035.vdocuments.us/reader035/viewer/2022070807/5f0657937e708231d4178342/html5/thumbnails/2.jpg)
ASY1-300FITTING ROOMS - SINGLE & DOUBLEPAGE 2 OF 11
I N S T A L L A T I O N I N S T R U C T I O N S
P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2
REV01
EU-24
DRICFDRDPSDRP
DRTRS DRPRPANEL RETAINER
DPSSPLICER
DRDPR-LHDOOR PANELRETAINER
DRDP-60DOOR PANEL
DROA & DRIAFLOOR ANCHOR
DROCF
MEBP-4830
MEBP-4830
MEBP-4836BH-436
BXH-430
STL-5
STL-5
STL-4
SS-4
SS-5
OBS-5
SL-4
DRDPSS
TLEG-16
-4
BU-96
DRDPR-RH
HARDWAREDRHPD
DOUBLEROOM
![Page 3: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas](https://reader035.vdocuments.us/reader035/viewer/2022070807/5f0657937e708231d4178342/html5/thumbnails/3.jpg)
ASY1-300FITTING ROOMS - SINGLE & DOUBLEPAGE 3 OF 12
I N S T A L L A T I O N I N S T R U C T I O N S
P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2
REV01
Lay out accurate chalklines on the floor forlocation of uprights as shown at right. Singlefitting room and double fitting room usesame dimensions.
1
Build perimeter walls as shown at right.Note location of TLEG shoes. Double fittingroom is shown.
2UPRIGHT
![Page 4: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas](https://reader035.vdocuments.us/reader035/viewer/2022070807/5f0657937e708231d4178342/html5/thumbnails/4.jpg)
ASY1-300FITTING ROOMS - SINGLE & DOUBLE PAGE 4 OF 11
I N S T A L L A T I O N I N S T R U C T I O N S
P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2
REV01
Side wall sections for both single & doublefitting rooms use same components. Metalpanels go to outside. Silver laminate goes tooutside for extension panels.
3
EU-24
BU-96
![Page 5: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas](https://reader035.vdocuments.us/reader035/viewer/2022070807/5f0657937e708231d4178342/html5/thumbnails/5.jpg)
ASY1-300FITTING ROOMS - SINGLE & DOUBLE PAGE 5 OF 11
I N S T A L L A T I O N I N S T R U C T I O N S
P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2
REV01
Retainer pins MUST be installed in TLEGshoes. Install standard base shoes tem-porarliy to stablize walls until corners arebuilt. Engage lock clip on base shoes.Once walls are joined for corners, retractlock clips and remove base shoes straightout.
4
OBSOPEN BACK STIFFNERS BOLT TO UPRIGHTS
OBS bolts to uprights. Lower spannersinstall just above OBS. Continue up withMetal Backs and splicer spanners. Installtop caps at top. Do not install extensionsat this time.
5
![Page 6: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas](https://reader035.vdocuments.us/reader035/viewer/2022070807/5f0657937e708231d4178342/html5/thumbnails/6.jpg)
ASY1-300FITTING ROOMS - SINGLE & DOUBLE PAGE 6 OF 11
I N S T A L L A T I O N I N S T R U C T I O N S
P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2
REV 01
After side walls are built, stand corneruprights (no shoes) at 90° and installspacers into lances. Four per corner.
6
DRUS, SPACER
NOTE:FOR SINGLE ROOMS...SET HANDICAP BENCH IN PLACE ANDCONSTRUCT WALLS AROUND BENCH -BENCH IS TOO LARGE TO SET IN PLACEAFTER ROOM IS CONSTRUCTED. BENCHSECURES TO REAR PANELS WITH DRY-WALL SCREWS. WAIT UNTIL LAST STEPTO SECURE BENCH!
SECURE BENCHAFTER WALLSBUILT
DRHB & DRCB
![Page 7: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas](https://reader035.vdocuments.us/reader035/viewer/2022070807/5f0657937e708231d4178342/html5/thumbnails/7.jpg)
ASY1-300FITTING ROOMS - SINGLE & DOUBLE PAGE 7 OF 11
I N S T A L L A T I O N I N S T R U C T I O N S
P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2
REV 01
FOR DOUBLE FITTING ROOMS...Install LH & RH divider panel retainers intomiddle uprights on interior of walls. Tabsengage upright slots.
7
Locate lower divider panel in placebetween retainers and resting on floor.Run screws into panel through retainers.Locate splicer on top of lower panel andinstall upper panel. Secure splicer andupper panel with screws.
8
DRDPSSSPLICER
DRPR
DRPR
![Page 8: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas](https://reader035.vdocuments.us/reader035/viewer/2022070807/5f0657937e708231d4178342/html5/thumbnails/8.jpg)
ASY1-300FITTING ROOMS - SINGLE & DOUBLE PAGE 8 OF 11
I N S T A L L A T I O N I N S T R U C T I O N S
P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2
REV 01
Install upright extensions and tightenexpansion screws as shown.
9
Install corner spacers (2) for each cor-ner.
10Install extension backs and top span-
ners.11
Slide outside corner covers into place.Covers are retained between the uprightedges and the spacers.
12COVER IN PLACE
DRUS
DROCF
![Page 9: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas](https://reader035.vdocuments.us/reader035/viewer/2022070807/5f0657937e708231d4178342/html5/thumbnails/9.jpg)
ASY1-300FITTING ROOMS - SINGLE & DOUBLE PAGE 9 OF 11
I N S T A L L A T I O N I N S T R U C T I O N S
P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2
REV 01
1/4-20 x 1”SCREW
Install upright inserts (6) into side wallupright tops until they catch in lances
and can not be pulled out.
13
Install wall stabilizer rails over walllength, covering spanners and uprights.Use the provided 1” screws to securestabilizers to inserts. Only install outside
screws at this time.
14
Install middle stabilizer on both singleand double rooms. Secure with samescrews that hold wall stabilizers to mid-dle upright inserts.
15 1/4-20 x 1”SCREW
![Page 10: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas](https://reader035.vdocuments.us/reader035/viewer/2022070807/5f0657937e708231d4178342/html5/thumbnails/10.jpg)
ASY1-300FITTING ROOMS - SINGLE & DOUBLE PAGE 10 OF 11
I N S T A L L A T I O N I N S T R U C T I O N S
P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2
REV 01
Install trim to interior faces of uprightsusing plactic fasteners as shown.
16 NOTE: IT IS RECOMMENDED THAT ALL VERTICALAND HORIZONTAL SEAMS BE CAULKED WITHCLEAR SILICONE FOR SECURITY AND THEFT
PEVENTION!
Position benches in rooms as shown.1
DRCB,
DRCB,
DRHB,
DRICFDRICF
![Page 11: PAGE 1 OF 11 FITTING ROOMS - SINGLE & DOUBLE ASY1-300fitting rooms - single & double asy1-300 page 1 of 11 i n s t a l l a t i o n i n s t r u c t i o n s p.o. box 729 / terrell, texas](https://reader035.vdocuments.us/reader035/viewer/2022070807/5f0657937e708231d4178342/html5/thumbnails/11.jpg)
ASY1-300FITTING ROOMS - SINGLE & DOUBLE PAGE 11 OF 11
I N S T A L L A T I O N I N S T R U C T I O N S
P. O . B OX 7 2 9 / T E R R E L L , T E X A S 7 5 1 6 0 / 9 7 2 . 5 6 3 . 5 7 4 4 / 8 0 0 . 7 7 6 . 2 3 4 9P. O . B OX 1 7 7 / G O O D W AT E R , A L A B A M A 3 5 0 7 2 / 2 0 5 . 8 3 9 . 6 3 5 4 / 8 0 0 . 6 3 3 . 6 2 8 2
REV 01
Door panels ate stabilized at bottomwith floor anchors, as indicated by starsay right (DOUBLE room is shown - SIN-GLE only takes (2) anchors on doorside) Rough opening width is 38 3/4”.Install the anchors adjacent to the doorcasing as shown. Install anchorsAFTER the door units are in place.
17
DRIA,
DROA,