paddy regan department of physics university of surrey & national physical laboratory, uk

46
New decay and isomer physics studies with fast scintillation detection arrays at Coulomb Barrier separator focal planes Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK [email protected]

Upload: nora-webster

Post on 04-Jan-2016

35 views

Category:

Documents


0 download

DESCRIPTION

New decay and isomer physics studies with fast scintillation detection arrays at Coulomb Barrier separator focal planes. Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK [email protected]. Nuclear structure information. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

New decay and isomer physics studies with fast scintillation detection arrays at Coulomb Barrier separator focal planes

Paddy ReganDepartment of Physics

University of Surrey&

National Physical Laboratory, [email protected]

Page 2: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

How is measuring the lifetime

useful?

Transition probability (i.e., 1/mean lifetime as measured for state which decays by EM radiation)

(trivial) gamma-rayenergy dependence oftransition rate, goes as. E

2L+1 e.g., E5 for E2s

for example.

Nuclear structure information. The ‘reduced matrix element’ , B(L) tells us the overlapbetween the initial and final nuclear single-particle wavefunctions.

Page 3: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

Annual Review of Nuclear Science (1968) 18 p265-290

Page 4: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

FATIMA for DESPEC

• FATIMA = FAst TIMing Array = A high efficiency, gamma-ray detection array for precision measurements of nuclear structure in the most exotic and rare nuclei.

• Specs.– Good energy resolution.– Good detection efficiency– Excellent timing qualities (~100 picoseconds).

• (2012) Bought 31 x LaBr3 1.5” x 2” crystals for array (expect 36 in total).

• Can use to measure lifetimes of excited nuclear states; provide precision tests of shell model theories of nuclear structure.

• UK contribution to DESPEC (Decay Spectroscopy) project within NUSTAR.

• Part of ~ £8M UK STFC NUSTAR project grant (runs to 2015).

Page 5: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK
Page 6: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

Brighton & Surrey groups purchased 31 1.5” x 2” LaBr3 detectors from St Gobain (Dec. 2012). Mounted into designed holders with Hamamatsu PMTs Jan 2013.

Page 7: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

T1/2 = 1.4ns

Tests with 152Eu source to measure lifetime of I=2+ 122 keV level in 152Sm.

Page 8: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK
Page 9: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK
Page 10: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

PMTPMT

Digitizer

CFD

Trigger

AnodeDynode

Dynode

4 GS/s (250 ps sampling interval)10 bit resolution,1 Volt input dynamic range,4 GHz Bandwidth

To PC for offline analysis

Source

Digital CFD for timingCR-RC, Trapezoidal filters for energy

Acqiris digitizer model DC252HF.Tests by Mohammad Nakhostin (U. Surrey)

Page 11: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

0 200 400 600 800 10000

100

200

300

400

500

600

700

Co

unts

Channel Number

Sample energy spectrum, 137Cs

Page 12: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

0.0 0.5 1.0 1.5 2.0 2.5 3.0

250

300

Tim

e re

solu

tion

(ps)

Sampling interval (ns)

Time resolution vs pulse sampling rate

Energy gate: 1100-1400 keV

Still preliminary!

Analog result

Page 13: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

100 150 200 250 300 350 4000

10

20

30

40

50

60

C

ount

s

Time (channel)

1100-1400 keV 100-400 keV

Digital time spectra for two different energy gates

The width and peak location of time spectra move with energy

Page 14: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.53.4

3.6

3.8

4.0

4.2

4.4

4.6

4.8

5.0

5.2

5.4

Ener

gy re

solu

tion

(%)

Sampling interval (ns)

B

Energy resolution vs sampling rate

Page 15: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

137Cs source gives (initial) testenergy resolution of ~3.5% at 662 keV.Note presence of internal radioactivity in detector.PMT HV range ~1300 V

1436 keV EC(2+→ 0+ in 138Ba)789 keV + -

In 138Ce

Ba x-rays from 137Cs & EC from 138La decay

Page 16: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

138La, T1/2=1.02x1011 yearsA.A.Sonzogni, NDS 98 (2003) 515

5+ 138La

1435.8138Ba82

2+

0+

ec (66%)

0+

2+

138Ce80

788.7

- (34%)

Page 17: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK
Page 18: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK
Page 19: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

An experimental example:138Ce80

Page 20: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

(h11/2)-2 only

N=80 Isotones

0+

2+

4+

6+

8+

10+isomer

Primarily(d5/2)2

Primarily(g7/2)2

•N = 80 isotones above Z = 50 display 10+ seniority isomers from coupling of (h11/2)-2

•6+ level decays also usually ‘hindered’ e.g., in 136Ba, T1/2 = 3.1(1)ns.

•Thought to be due to change in configuration and seniority.

Page 21: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

N=80 Isotones•Neighbouring N=80 nuclei, 138Ce and 140Nd expected to show

similar 6+ → 4+ hindrance.

•Competing transitions to negative parity states •E1 decays, forbidden in truncated shell model space.

Page 22: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

Restricted basis SM calculations give reasonable comparison with experimental (near-yrast) states in 138Ce.

What about transition rates?

Page 23: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

130Te(12C,4n)138Ce @56 MeV

Page 24: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

T.Alharbi et al., Phys. Rev. C87 (2013) 014323

138Ce80

Page 25: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK
Page 26: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

138Ce80

Page 27: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

138Ce80

Page 28: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

S.-J. Zhu et al. Chin.Phys.Lett. 16, 635 (1999)

T1/2 = 140(11)ps

Using “delayed” HPGe gate

138Ce – Lifetime of the 11+ State

Page 29: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK
Page 30: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

188W

Page 31: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

2 neutrons more than heaviest stable Tungsten(Z=74) isotope (186W).

Populate 188W using 186W(7Li,ap)188W ‘incomplete fusion’ reaction.

(Not really a fusion-evapreaction, but populates medium spin states).

See e.g., Dracoulis et al., J. Phys. G23(1997) 1191-1202

110 111 112 113 114 115 N

Page 32: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

Half-life of the yrast 2+ state in 188W

•Neutron-rich A ~ 190 nuclei, a long predicted prolate – oblate shape transition region. e.g. Bengtsson et al. PLB190 (1987) 1

•Unusual (energy) deviation at 190W compared to trend of other nuclides.

•Measurement of B(E2;2+ →0+) gives best measure of (evolution of) low-lying collectivity

Page 33: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

Half-life of the yrast 2+ state in 188W

•16 mg/cm2 186W target with thick Pb backing •186W(7Li,p)188W. 31-, 33-MeV beam (Coul. Barr. ~ 29 MeV)

•Estimated 0.1-1 mb•Strongest channels:187Re (1-p transfer)189Ir (fusion-evap)

Page 34: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

•Sum of time differences between 143-keV (2->0) transition and any higher lying feeding transition.

Page 35: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

T1/2 =0.87(12)

ns

Time difference between 143 keV2+→0+ and feeding transitions.

Page 36: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

188W 188W

188W

Page 37: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

Other Recent Uses of Fatima Detectors

• 21 detectors went RIKEN for use in EURICA array from Nov. 2012 (see poster by Frank Browne).

• 8 detectors used with EXOGAM@ILL from Feb. – March 2013 for use in 235U(n,f) experimental campaign.

Page 38: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK
Page 39: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

140 keV 2+ →0+ in 104Zr

Demonstrates that beta-gamma time differences can be used in projectile fragmentation/fissionspectroscopy to measure, e.g., 2+ lifetimes in many, even-even, exotic nuclei, down to ~100 ps?

Page 40: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

EXILL + FATIMAEXOGAM

+ FATIMA LaBr3 array at ILL Grenoble

Ge-Ge-LaBr3-LaBr3

quadruple coincs between prompt gammas from fissionfragments in 235U(n,f) reaction usingthermal neutrons.. Massive data set, underanalysis (led by Koln group)

Page 41: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

Delayed Gammas

Isomeric state

PROMPT gammas

Isomeric state

Tagging Methods at Jyväskylä

Trigger-less Data Acquisition System

• JUROGAM, RITU, GREAT and the TDR.

D.M. Cullen, Physics with Large Arrays of Novel Scintillators, Dublin, Jan 2014

Page 42: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

Delayed γ rays but in prompt coincidence with each other (ps lifetimes)

Measure LaBr3 – LaBr3 coincidences with ~200ps intrinsic LaBr3 timing resolution.

Extract lifetimes down to ~5ps (centroid shift).

Isomeric state (~100ns – several µs)

~ 100ps

~ 50ps

~ 5ps

D.M. Cullen, Physics with Large Arrays of Novel Scintillators, Dublin, Jan 2014

Ground state

Technique

Page 43: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

Possible array configuration at focal plane of RITU spectrometer at JYFL

Page 44: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

An experimental challenge….

Page 45: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

1.N=74 K-Isomers e.g. 138Gd / 140Dy? to address the deformation of ground-state bands approaching the proton drip-line. Deformations used in hindrance calculations and also proton decay tunnelling calculations but not yet measured.

2.Deformation of states in neutron deficient Pb (188-194) under known isomers (11- isomers and K isomers).

3.States below the 14+ isomer in 94Pd giving information on n-p pairing.

4....

Some potential Physics Experiments at RITU:

D.M. Cullen, Physics with Large Arrays of Novel Scintillators, Dublin, Jan 2014

1. Minimum half-life possible is ~ few 100 ns(flight time through RITU, depends on v/c)

2. Maximum half-life possible is ~ few ms (depending on tagging method and implant

rate (beam current)).

Page 46: Paddy Regan Department of Physics University of Surrey & National Physical Laboratory, UK

Acknowledgements• Zsolt Podolyák, Peter Mason, Thamer

Alharbi, Christopher Townsley, Daniel Terver, Laila Gurgi, Mohammad Nakhostin (Surrey)

• Alison Bruce, Oliver Roberts, Frank Browne (Brighton)

• Dave Cullen et al. (Manchester)• Nicu Marginean et al., (Bucharest)• Funding for detectors and DAQ from STFC

UK.