The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc. ©Copyright 2014 Dwyer Instruments, Inc.TRANSCRIPT
![Page 1: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/1.jpg)
Paddlewheel Flow Sensors
The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific,
written prior permission from Dwyer Instruments, Inc. ©Copyright 2014 Dwyer Instruments, Inc.
![Page 2: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/2.jpg)
Overview
PFT - Paddlewheel Flow Transmitter
IPFS - Paddle Flow Sensor
PDWS - Paddle Flow Sensor
DFMT/DFMT2 - Digital Paddle Flow Transmitter
![Page 3: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/3.jpg)
Operation Principle
Paddlewheel Flow Sensors
Minimally invasive monitoring of fluid velocity in industrial pipesCost effective in comparison to other technologies
![Page 4: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/4.jpg)
PFT - Introduction
Paddlewheel transmitterInductive rotor sensing, no magnets
Good for magnetic materials
![Page 5: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/5.jpg)
PFT - Specifications
Adjustable from 1-1/2 to 40” (38 to 1016 mm) pipes1.2 to 25 ft/s (0.37 to 7.62 m/s)Linearity ±1% full rangeRepeatability ±0.5% full rangeNEMA 6P (IP69)
![Page 6: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/6.jpg)
PFT - Features
One unit adjustable for range of pipe sizes
1-1/2 to 40” (76 to 1016 mm)
Pulse or 4-20 mA output signalIn one unit with no need for converter
Brass or stainless body, variety of o-ringsLow friction bearings
![Page 7: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/7.jpg)
IPFS - Introduction
Adjustable insertion paddlewheel transmitterHall Effect sensor with pulse signal output
Good for low flow
![Page 8: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/8.jpg)
IPFS - Specifications
Adjustable between 3 to 40” (76 to 1016 mm) pipes0.3 to 30 ft/s (0.09 to 9.14 m/s)Accuracy ±1.5% full rangeNEMA 4X (IP66)
![Page 9: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/9.jpg)
IPFS - Features
Adjustable for range of pipe sizesBrass, PVC, or stainlessHot tap option (brass or stainless)Use with Series SDF fittingsOptional bi-directional sensor
![Page 10: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/10.jpg)
SDF FittingsUse with PFT and IPFS sensorsBrass or iron, 3 to 24” (76 to 609 mm) pipe size
![Page 11: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/11.jpg)
PDWS - Introduction
Fixed insertion paddlewheel transmitterHall Effect sensor with pulse signal output
Good for low flow
![Page 12: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/12.jpg)
PDWS - Specifications
Pipe sizes ½ to 8” (12.7 to 203 mm)0.3 to 30 ft/s (0.09 to 9.14 m/s)Accuracy ±1.5% full rangeNEMA 4X (IP66)
![Page 13: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/13.jpg)
PDWS - Features
Brass, stainless, PVC, or polypropylene bodyUse with Series PWF fittings and teesHigh pressure optionsImmersion options
![Page 14: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/14.jpg)
PWF - Fittings
Use with PDWS sensorBronze, PVC, SS, and steel½ to 8” pipes
(12.7 to 203 mm)
![Page 15: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/15.jpg)
DFMT & DFMT2 - Introduction
Digital paddlewheel sensorHall Effect sensor with analog or pulse output
Good for low flow
DFMT
DFMT2
![Page 16: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/16.jpg)
DFMT & DFMT2 - Specifications
Sizes from 3/8 to 2” NPT ( 9.5 to 51 mm)Measures flow from 0.5 to 180 GPM (0.1 to 40.0 m3/h)Accuracy ±1.5% full rangeIP65 ratingOptional RS485 communications
DFMT
DFMT2
![Page 17: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/17.jpg)
DFMT & DFMT2 - Features
Measures instantaneous and total flowResettable totalizerUser selectable 4-20mA or pulsed outputEasy to use push buttons for programmingPassword Protection
DFMT
DFMT2
![Page 18: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/18.jpg)
BAT Transmitter
Blind Analog TransmitterUse with IPFS and PDWSConverts pulse to 4-20mAMeter or wall mount
![Page 19: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/19.jpg)
RTI Transmitter
Rate/Total IndicatorUse with IPFS and PDWSConverts pulse to 4-20mAMeter, panel, or wall mount
![Page 20: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/20.jpg)
PWD Pulse Divider
Pulse DividerUse with any pulse output transmitterPace electronic pumps
![Page 21: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/21.jpg)
Applications
IrrigationGround water remediationCooling systemsPump flow provingChemical ProportioningReverse Osmosis
![Page 22: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/22.jpg)
Irrigation
Monitor water flow rate for pivot irrigation systems and drip irrigation systemsEnsure proper water transfer
![Page 23: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/23.jpg)
Groundwater Remediation
Monitor flow rate of water usage from water source for the purpose of cleaning water source
![Page 24: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/24.jpg)
Cooling SystemsMonitor water flow in and out of cooling system Use for obtaining BTU usage and monitoring efficiency with BAS system
![Page 25: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/25.jpg)
Chemical Proportioning
Pump proving
Continuous monitoring of chemical usage for ideal chemical proportioning or dosing
![Page 26: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/26.jpg)
Reverse Osmosis
Monitor water flow in and out of water filtration systemDetermine amount of water being processed
![Page 27: Paddlewheel Flow Sensors](https://reader038.vdocuments.us/reader038/viewer/2022103000/55693454d8b42add468b4fe6/html5/thumbnails/27.jpg)
The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc. ©Copyright 2014 Dwyer Instruments, Inc.