Whenever you are asked to cross reference a brand of HVAC packaged equipment, special care must be
taken to address all of the potential variables.
ALWAYS get the voltage, fuel type, and unit configuration! Never rely solely on the model number.
In addition, sometimes the model number does not reflect field or factory installed features & accessories.
To that end, its always important to "exclude" any items which are not specifically listed on your quote.
The attached cross reference charts are NOT intended to be a complete and total list of all models in the field.
Rather, the goal of building this reference guide is to simplify cross referencing roughly 60-70% of the models
encountered on a daily basis.
Please note: It is the contractor's responsibility to confirm the correctness of the project tonnage
requirements, voltage, & any required accessories.
Packaged Unit Cross-Reference Guide
CARRIER
1 2 3 4 5 6 7 8 V
Sample Model #: 4 8 D J Q 0 0 8 - 5
Digits 1,2: Voltage Indicator:
48 = Gas/Elect Pkg Unit -1 575/3/60
50 = Electric Pkg Unit -3 208/240-1-60
-5 208/240-3-60
Digits 3,4: -6 460-3-60
Product Series, for example:
DJ, LJ, TJ, HJ, HE Digits 6,7,8: Tonnage:
004 3-tons
Digit 5: Heat Type: 005 4-tons
D Low Heat 006 5-tons
E Med Heat 007 6-tons
F High Heat 008 7.5-tons
L Low Heat, Low NOX 009 8.5-tons
M Med Heat, Low NOX 012 10-tons
N High Heat, Low NOX 014 12.5-tons
Q Heat Pump 016 15-tons
020 18-tons
025 20-tons
028 25-tons
BRYANT
1 2 3 4 5 6 7 8 9 10 11 12
Sample Model #: 5 8 1 B E V 0 9 0 1 8 0
Digits 1,2,3,4: Digits 10, 11, 12: BTUH Input
Product Series, for example: 115 115,000 Input
581B = 3 to 12.5 ton Gas/Elec 180 180,000 Input
Digits 5: Voltage Indicator: Digits 7,8,9: Tonnage:
E 460-3-60 036 3-tons
J 208/240-1-60 048 4-tons
P 208/240-3-60 060 5-tons
T 575/3/60 072 6-tons
090 7.5-tons
Digits 6: Fuel 102 8.5-tons
V Nat Gas/ Spark Ignition 120 10-tons
150 12.5-tons
180 15-tons
020 18-tons
025 20-tons
028 25-tons
Digit Number
Digit Number
OLD LENNOX
1 2 3 4 5 6 7 8 9 10 11 V
Sample Model #: G C S 1 6 9 5 3 2 0 0 -Y
Digits 1,2,3: Digits 10, 11, 12: BTUH Input
GCS = Gas/Electric Pkg 125 125,000 Input
CHA = Electric / Electric Pkg 200 200,000 Input
CHP = Heat Pump Pkg 270 270,000 Input
Digits 4,5: Digits 6,7,8: Tonnage:
Product Series, for example: 413 3-tons, 3-phase
9,11,16,20,24 series 513 4-tons, 3-phase
653 5-tons, 3-phase
Voltage Indicator: 813 6-tons, 3-phase
P 208/240-1-60 953 7.5-tons, 3-phase
Y 208/240-3-60 1353 10-tons, 3-phase
G 460-3-60 1653 12.5-tons, 3-phase
J 575/3/60 1853 15-tons, 3-phase
2553 20-tons, 3-phase
3003 25-tons, 3-phase
TRANE
1 2 3 4 5 6 7 8 9 10
Sample Model #: Y S C 0 9 0 E 3 E L
Digits 1: Digit 10: Heating Capacity
Y = Gas/Electric Pkg Unit B 6kw - 3ph
T = Elect / Elect Pkg Unit E 8kw - 3ph
W = Heat Pump Pkg Unit G 12kw - 3ph
Digit 2: Efficiency J 23kw - 3ph
S = Std Eff / H = High Eff L Low Ht, Gas
Digit 3: C = Convertible M Med Ht, Gas
H High Ht, Gas
Digits 3,4,5: Tonnage:
036 3-tons Digit 9: Unit Controls
048 4-tons E Electro-Mech
060 5-tons R ReliaTel MicroProcess
072 6-tons
090 7.5-tons Digit 8: Voltage Indicator
102 8.5-tons 1 208/240-1-60
120 10-tons 3 208/240-3-60
150 12.5-tons 4 460-3-60
180 15-tons W 575/3/60
210 17.5-tons
240 20-tons Digits 7: Major Design Seq.
300 25-tons E = R410A
Digit Number
Digit Number
YORK
1 2 3 4 5 6 7 8 9 10
Sample Model #: Z H 0 9 0 N 1 0 A 2
Digits 1: Digit 10: Voltage Indicator
Z = Cooling Pkg Unit 2 208/240-3-60
X = Heat Pump Pkg Unit 4 460-3-60
5 575/3/60
Digit 2: Efficiency
H = 11+ EER, A/C Digits 9: Airflow
P = 11+ EER, HP A Std Motor
J = 11+ EER A/C N Hi Static Motor
F = 10 to 11 EER Others Fact Ins O/A Access
R = ReHeat
Digits 6,7,8: Heating
Digits 3,4,5: Tonnage: N10 105,000 Input
036 3-tons N15 150,000 Input
048 4-tons N20 200,000 Input
060 5-tons E09 9kw
078 6.5-tons E18 18kw
090 7.5-tons E24 24kw
102 8.5-tons
120 10-tons
150 12.5-tons
180 15-tons
210 17.5-tons
240 20-tons
300 25-tons
Digit Number