p3.0 series - promationei.com · the p3.0 series can be ordered as an on/off (two position) model...

4
SD15_P234_0_HV Ver M_041615 204450 C US ® Duty cycle is defined as the ratio of run time vs. off time, and is a function of environmental conditions including ambient temperature, supply voltage and control signal stability Duty cycle graph Product Ordering Example: 50°F 10°C 75°F 24°C 100°F 38°C 125°F 52°C 150°F 65°C 25% 50% 75% 100% On/Off/Jog Ambient Temperature Page 1 of 4 P3.0 Series Data Sheet P3.0 Series On/Off/Jog ISO5211 F07 8P22 An electric actuator designed for load requirements up to 1150”lbs. The actuator comes standard with two auxiliary switches (Form C), an internal low power heater, a NEMA 4X environmental rating, and in 120vac and 230vac supply voltages. The P3.0 mechanical connections are ISO5211 compliant. The P3.0 Series can be ordered as an on/off (two position) model that can be used in bump/jog applications as well. On/Off Non-Spring Return 3.0 N NEMA 4X 4 P 3.0 - 120 N 4 Product Family Control Voltage Options 1150”lbs / 130Nm 120 230 120VAC610% 230VAC610% Note: Not all combinations are possible. Please consult factory. Environmental Operation Actuator Specifications P3.0 Torque “lb/Nm 1150”lbs/130Nm Supply Voltage 120vac 230vac Max Inrush Current 1.8A 1.2A Running Current 1.2A 1.0A Motor Split Phase Capacitor Runtime (90°@60Hz/vdc) 22 sec Runtime (90 O @50Hz) 26 sec Duty Cycle 25% Motor Starts 1200 per hour Weight 26lbs/12kg Mechanical Connections ISO5211 F07 8pt 22mm Electrical Entry (2) 3/4” NPT Electrical Terminations 12-16ga Environmental Rating NEMA 4/4X Manual Override 5” Handwheel Control On/Off-Jog ONLY Actuator Case Material Aluminum Alloy, Powder coated Motor Protection 230°F/110°C Thermal F* Class *Totally Enclosed Non-Ventilated Motors Ambient Temperature Operating Range -22°F to +125°F -30°C to +52°C

Upload: others

Post on 21-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: P3.0 Series - promationei.com · The P3.0 Series can be ordered as an on/off (two position) model that can be used in bump/jog applications as well. On/Off Non-Spring 3.0 N Return

SD

15_P234_0_H

V Ver M

_041615

204450C US

®• Dutycycleisdefinedastheratioofruntimevs.off

time,andisafunctionofenvironmentalconditionsincludingambienttemperature,supplyvoltageandcontrolsignalstability

Duty cycle graph

Product Ordering Example:CSA Certified Duty Cycle Graph Duty Cycle Graph

50°F10°C

75°F24°C

100°F38°C

125°F52°C

150°F65°C

25%

50%

75%

100%

On/Off/Jog

Ambient Temperature Ambient Temperature

CSA Certified Duty Cycle Graph

50°F10°C

75°F24°C

100°F38°C

125°F52°C

150°F65°C

25%

50%

75%

100%

On/Off/Jog

Duty Cycle Graph

50°F10°C

75°F24°C

100°F38°C

125°F52°C

150°F65°C

25%

50%

75%

100%

On/Off/Jog

Proportional

Ambient Temperature

50°F10°C

75°F24°C

100°F38°C

125°F52°C

150°F65°C

25%

50%

75%

100%

On/Off/Jog

Proportional

Ambient Temperature

Page1of4P3.0Series

Data Sheet

P3.0 SeriesOn/Off/Jog

ISO5211 F07 8P22

Anelectricactuatordesignedforloadrequirementsupto1150”lbs.Theactuatorcomesstandardwithtwoauxiliaryswitches(FormC),aninternallowpowerheater,aNEMA4Xenvironmentalrating,andin120vacand230vacsupplyvoltages.TheP3.0mechanicalconnectionsareISO5211compliant.TheP3.0Seriescanbeorderedasanon/off(twoposition)modelthatcanbeusedinbump/jogapplicationsaswell.

On/Off Non-SpringReturn3.0 N NEMA4X4

P 3.0 - 120 N 4 Product Family ControlVoltage Options

1150”lbs / 130Nm120

230

120VAC610%

230VAC610%

Note: Not all combinations are possible. Please consult factory.

EnvironmentalOperation

Actuator Specifications P3.0Torque“lb/Nm 1150”lbs/130NmSupplyVoltage 120vac 230vacMaxInrushCurrent 1.8A 1.2ARunningCurrent 1.2A 1.0AMotor SplitPhaseCapacitorRuntime(90°@60Hz/vdc) 22 secRuntime(90O@50Hz) 26 secDuty Cycle 25% MotorStarts 1200perhourWeight 26lbs/12kgMechanicalConnections ISO5211F078pt22mmElectricalEntry (2)3/4”NPTElectricalTerminations 12-16gaEnvironmentalRating NEMA4/4XManualOverride 5”HandwheelControl On/Off-JogONLYActuatorCaseMaterial AluminumAlloy,Powdercoated

MotorProtection 230°F/110°CThermalF*Class*TotallyEnclosedNon-VentilatedMotors

AmbientTemperature OperatingRange

-22°Fto+125°F-30°Cto+52°C

Page 2: P3.0 Series - promationei.com · The P3.0 Series can be ordered as an on/off (two position) model that can be used in bump/jog applications as well. On/Off Non-Spring 3.0 N Return

SD

15_P

234_

0_H

V V

er M

_041

615

On/Off/Jog Control

WiresizingdataisprovidedinthetablebelowtoassistintheselectionoftheproperwiresizeforProMationPSeriesactuatorsusingvariouswiresizesoverdistance.

Pleasemakesuretoreferencethecorrectvoltageanddonotexceed the indicated lengthof thewire run foreachmodel.

• FieldControlDevicemayberelaycontact,SwitchorTriactype.

• Pilotdevice10AMAX.Auxiliaryswitchesarerated10A@250vacMAX.

• Terminals7-12aredrytypeFormC.• Terminalsaccept12-16gasolid/strandedwire.

SAMPLE DIAGRAMRefertotheproperIOMforyouractuatorforthecorrectwiringdiagramorvisitwww.promationei.com.

Switch Logic Map and Switch/Cam ArrangementSwitchsequencingdataisprovidedinthetablebelowtoshowthechange-of-statepointsduringtherotationoftheactuatorfromOPENtoCLOSEDandbackagain.Theredbarindicateswhenthatterminalmakeswithit’srespectivecommon.

SW1andSW2are set at the factory and shouldNOTbechanged.TheINCLUDEDauxiliaryswitchesSW3&SW4areforterminals7thru12andthosesetpointsmaybemodifiedifneedbe.Whensooptioned,SW5&SW6auxiliaryswitchesare initially set to function the sameas auxiliary switchesSW3&SW4.

On/Off Switch/Cam arrangement shown

TerminalID

#

12

11

10

9

8

7

-5° 0°CW CCW

85°5° 90° 95°

SW3 CCW AUX(FactorySet-Adj)

SW4 CW AUX(FactorySet-Adj)}

}Closed Common

Open Common

}UsedbyController

Open

Not Closed

Closed

Not Open

Page2of4P3.0Series

Wiring Diagrams for P3.0 Series

12

11

10

9

8

7

GND Screw

M

SW3

SW4

THERMALSWITCH

AUXILIARYSWITCH

(STANDARD)

ALL SWITCHESSHOWN WITHACTUATOR IN

FULL OPENPOSITION

AUXILIARYSWITCH

(STANDARD)

Red7"

Direct MountHeater

Blk8"

Wht8"

Wht12"

Blk12"

E1E2

Actuator ships in fully closed position!

410-50100TL25-1800

Capacitor410-3010012uF/250v

6

5

4

3

2

1

J1

HEATER

SW2

SW1

J2

E1E2

J3

112

43

Items within dotted line located inside actuator housing

430-10100 Switch Card

SW1

SW2

SW3

SW4

Switch StackDetail

NOT OPEN*

OPEN COM*

OPEN*

NOT CLOSED*

CLOSED COM*

CLOSED*

RUN OPEN

OPEN PILOT*

RUN CLOSED

CLOSED PILOT*

NEU

HOT

120VACLINE IN

* CONNECTIONSOPTIONAL

FIELDCONTROL

DEVICE

GND

120V AC Motor410-20100

(P2/3)

R (7")W (12")

B (12")

B (8")

W (8")

1

AW

D-8

50

-24

10

0

Use For:

P2/3-120N4-AC

Wire Sizing ChartMAXdistancebetweenActuator

andSupply(feet)

Actuator/ Voltage

P3.0 120VAC

P3.0 230VAC

1.8A 1.2A

16 722 207414 1166 335112 1783 512510 3030 87128 4523 13003

WireGage

Amps

120VAC 230VAC

Neu L2

Hot L1

GND GND

Page 3: P3.0 Series - promationei.com · The P3.0 Series can be ordered as an on/off (two position) model that can be used in bump/jog applications as well. On/Off Non-Spring 3.0 N Return

SD

15_P234_0_H

V Ver M

_041615

Page3of4P3.0Series

P3.0 Series Dimensional Data

1

1

2

2

A A

B B

Drawn By

Finish

Promation Engineering Inc.16138 Flight Path Drive

Brooksville, Fl 34604Phone: 352-544-8436Fax: 352-544-8439

This Document is the property of ProMation Engineering,Inc. Distribution of this document without the written

consent of the owner is Strictly forbidden. Failure to comply will incur a liability for Damages.

Checked By4/8/2015

P2~P3 Dim Data Rev.

G

NO SCALE Sheet Number: 1

Material

ProMation Engineering, Inc.KHL

KHL

4/25/2013

P2_3 F07 8P22 DimData.idw

Created:

Last Checked:

Part No.

Dwg. Name

Dimensional Data for P2~P3 Actuators

Engineering Change NoticeChange Date Description Name

04.25.13 Document transferred to Inventor format KHL

11.12.13 Added rounded edges on Drive Coupling Data KHL

04.15.2014 Added tolerance on drive coupling data KHL

10.07.2014 Pushed square dimension to three decimal places KHL

REV

A

B

C

D

E

F

Dimensional Tolerances (Unless Otherwise Noted):X ± 2.5mm [X.X ± .1]

X.X ± .3mm [X.XX ± .01"]X.XX ± .13mm [X.XXX ± .005"]

ALL TOLERANCE FEATURES IN mm

G 04.08.2015 Added Isometric view of Drive Coupling and "Depth" tag for clarity KHL

H

Drive Coupling Fabrication Data

22.00 - .13.00+ mm

0.866 - 0.0050.000+ in

22.00 - .13.00+ mm

0.866 - 0.0050.000+ in

30.00 mm1.181 inDepth

30.00 mm1.181 in

229 mm9.0 in

324 mm12.8 in

211 mm8.3 in

123 mm4.8 in

180 mm7.1 in

90 mm3.5 in

287 mm11.3 in

Add 257mm

[10.1"] to allowfor coverremoval

70 mm2.8 inBHC

22 mm0.9 in

(4) M8x1.25

20mm0.8"

F07 ISO Flange

(2) 3/4" NPTEMT Entry

125 mm4.9 in

86 mm3.4 in

P3.0 Series Views(Typical)

Page 4: P3.0 Series - promationei.com · The P3.0 Series can be ordered as an on/off (two position) model that can be used in bump/jog applications as well. On/Off Non-Spring 3.0 N Return

SD

15_P

234_

0_H

V V

er M

_041

615

Use your smart phone barcode scanner app here.

16138 Flight Path Drive Brooksville, FL 34604

Phone (352) 544-8436 Fax (352) 544-8439email: [email protected]

ProMation Engineering follows a policy of continual product updates and enhancements. Our website is the best place to obtain the latest product documentation, including the wiring diagrams for these controllers. Visit us at www.promationei.com or use the QR code below to link to the site.

ProMation Product Line

PL SeriesLinear Drive

Up to 4400lbs down/up force.

P SeriesNon-Spring Return

55”lbs through 40,000”lbs.

PA~PD Series Spring Return

445”lbs through 2300”lbs.

PBU Battery Back-Up Systems

Provides battery power to drive open

P Series Exploded View (Typical)

Application Notes:1. TheseactuatorsaretobemountedONLYbetweena

horizontalanduprightposition.2. Wheninstallingconduit,usepropertechniquesforentry

into the actuator.Use drip loops to prevent conduitcondensatefromenteringtheactuator.

3. BothNPTconduitportsMUSTuseproperequipmenttoprotecttheNEMA4Xintegrityofthehousing.

4. The anti-condensate heater is to be used inALLapplications.

5. Do not install or store the actuator outdoors or in humid environments without power to the heater.

6. Useproperwiresizetopreventactuator failure(seewiresizingchart).

7. Mechanicaltravelstopsexisttopreventover-rotationformanualoverrideonly.Theyarenotintendedtostopmotordrivenrotation.

8. Do not parallel wire multiple on/off actuators together without utilizing isolation relays!Ifthisisyourintention,pleasecontactProMationEngineeringforamultipleactuatorparallelwiringdiagram.

P Series Exploded View (P2/3-120N4 unit is shown)

Switchsequencingdataisprovidedinthetablebelowtoshowthechange-of-statepointsduringtherotationoftheactuatorfromCCWtoCWandbackagain.Theredbarshowswhenthatterminalmakeswith itsrespectivecommon.

Switches1and2aresetat thefactoryandshouldNOT be changed.The INCLUDEDauxiliaryswitchesSW3&SW4areforterminals7thru12andthosesetpointsmaybemodifiedifneedbe.Whensooptioned,SW5&SW6auxiliaryswitchesareinitiallysettofunctionthesameasauxiliaryswitchesSW3&SW4.

Easilydistinguishableyellow/redposition

indicator

WormDrive

HeavyDutyDriveMotor

Easilyaccessibleswitch&camstacks

ModularControlCards

ClutchlessOverride

Handwheel

AluminumCastingNEMA4XProtection

AluminumCastingNEMA4XProtection

EpicyclicGearing

MechanicalStopScrews(2)

NEMA4XCoverSeal

Switch Logic Map and Switch/Cam Arrangement

Page4of4P3.0Series