p3.0 series - promationei.com · the p3.0 series can be ordered as an on/off (two position) model...
TRANSCRIPT
SD
15_P234_0_H
V Ver M
_041615
204450C US
®• Dutycycleisdefinedastheratioofruntimevs.off
time,andisafunctionofenvironmentalconditionsincludingambienttemperature,supplyvoltageandcontrolsignalstability
Duty cycle graph
Product Ordering Example:CSA Certified Duty Cycle Graph Duty Cycle Graph
50°F10°C
75°F24°C
100°F38°C
125°F52°C
150°F65°C
25%
50%
75%
100%
On/Off/Jog
Ambient Temperature Ambient Temperature
CSA Certified Duty Cycle Graph
50°F10°C
75°F24°C
100°F38°C
125°F52°C
150°F65°C
25%
50%
75%
100%
On/Off/Jog
Duty Cycle Graph
50°F10°C
75°F24°C
100°F38°C
125°F52°C
150°F65°C
25%
50%
75%
100%
On/Off/Jog
Proportional
Ambient Temperature
50°F10°C
75°F24°C
100°F38°C
125°F52°C
150°F65°C
25%
50%
75%
100%
On/Off/Jog
Proportional
Ambient Temperature
Page1of4P3.0Series
Data Sheet
P3.0 SeriesOn/Off/Jog
ISO5211 F07 8P22
Anelectricactuatordesignedforloadrequirementsupto1150”lbs.Theactuatorcomesstandardwithtwoauxiliaryswitches(FormC),aninternallowpowerheater,aNEMA4Xenvironmentalrating,andin120vacand230vacsupplyvoltages.TheP3.0mechanicalconnectionsareISO5211compliant.TheP3.0Seriescanbeorderedasanon/off(twoposition)modelthatcanbeusedinbump/jogapplicationsaswell.
On/Off Non-SpringReturn3.0 N NEMA4X4
P 3.0 - 120 N 4 Product Family ControlVoltage Options
1150”lbs / 130Nm120
230
120VAC610%
230VAC610%
Note: Not all combinations are possible. Please consult factory.
EnvironmentalOperation
Actuator Specifications P3.0Torque“lb/Nm 1150”lbs/130NmSupplyVoltage 120vac 230vacMaxInrushCurrent 1.8A 1.2ARunningCurrent 1.2A 1.0AMotor SplitPhaseCapacitorRuntime(90°@60Hz/vdc) 22 secRuntime(90O@50Hz) 26 secDuty Cycle 25% MotorStarts 1200perhourWeight 26lbs/12kgMechanicalConnections ISO5211F078pt22mmElectricalEntry (2)3/4”NPTElectricalTerminations 12-16gaEnvironmentalRating NEMA4/4XManualOverride 5”HandwheelControl On/Off-JogONLYActuatorCaseMaterial AluminumAlloy,Powdercoated
MotorProtection 230°F/110°CThermalF*Class*TotallyEnclosedNon-VentilatedMotors
AmbientTemperature OperatingRange
-22°Fto+125°F-30°Cto+52°C
SD
15_P
234_
0_H
V V
er M
_041
615
On/Off/Jog Control
WiresizingdataisprovidedinthetablebelowtoassistintheselectionoftheproperwiresizeforProMationPSeriesactuatorsusingvariouswiresizesoverdistance.
Pleasemakesuretoreferencethecorrectvoltageanddonotexceed the indicated lengthof thewire run foreachmodel.
• FieldControlDevicemayberelaycontact,SwitchorTriactype.
• Pilotdevice10AMAX.Auxiliaryswitchesarerated10A@250vacMAX.
• Terminals7-12aredrytypeFormC.• Terminalsaccept12-16gasolid/strandedwire.
SAMPLE DIAGRAMRefertotheproperIOMforyouractuatorforthecorrectwiringdiagramorvisitwww.promationei.com.
Switch Logic Map and Switch/Cam ArrangementSwitchsequencingdataisprovidedinthetablebelowtoshowthechange-of-statepointsduringtherotationoftheactuatorfromOPENtoCLOSEDandbackagain.Theredbarindicateswhenthatterminalmakeswithit’srespectivecommon.
SW1andSW2are set at the factory and shouldNOTbechanged.TheINCLUDEDauxiliaryswitchesSW3&SW4areforterminals7thru12andthosesetpointsmaybemodifiedifneedbe.Whensooptioned,SW5&SW6auxiliaryswitchesare initially set to function the sameas auxiliary switchesSW3&SW4.
On/Off Switch/Cam arrangement shown
TerminalID
#
12
11
10
9
8
7
-5° 0°CW CCW
85°5° 90° 95°
SW3 CCW AUX(FactorySet-Adj)
SW4 CW AUX(FactorySet-Adj)}
}Closed Common
Open Common
}UsedbyController
Open
Not Closed
Closed
Not Open
Page2of4P3.0Series
Wiring Diagrams for P3.0 Series
12
11
10
9
8
7
GND Screw
M
SW3
SW4
THERMALSWITCH
AUXILIARYSWITCH
(STANDARD)
ALL SWITCHESSHOWN WITHACTUATOR IN
FULL OPENPOSITION
AUXILIARYSWITCH
(STANDARD)
Red7"
Direct MountHeater
Blk8"
Wht8"
Wht12"
Blk12"
E1E2
Actuator ships in fully closed position!
410-50100TL25-1800
Capacitor410-3010012uF/250v
6
5
4
3
2
1
J1
HEATER
SW2
SW1
J2
E1E2
J3
112
43
Items within dotted line located inside actuator housing
430-10100 Switch Card
SW1
SW2
SW3
SW4
Switch StackDetail
NOT OPEN*
OPEN COM*
OPEN*
NOT CLOSED*
CLOSED COM*
CLOSED*
RUN OPEN
OPEN PILOT*
RUN CLOSED
CLOSED PILOT*
NEU
HOT
120VACLINE IN
* CONNECTIONSOPTIONAL
FIELDCONTROL
DEVICE
GND
120V AC Motor410-20100
(P2/3)
R (7")W (12")
B (12")
B (8")
W (8")
1
AW
D-8
50
-24
10
0
Use For:
P2/3-120N4-AC
Wire Sizing ChartMAXdistancebetweenActuator
andSupply(feet)
Actuator/ Voltage
P3.0 120VAC
P3.0 230VAC
1.8A 1.2A
16 722 207414 1166 335112 1783 512510 3030 87128 4523 13003
WireGage
Amps
120VAC 230VAC
Neu L2
Hot L1
GND GND
SD
15_P234_0_H
V Ver M
_041615
Page3of4P3.0Series
P3.0 Series Dimensional Data
1
1
2
2
A A
B B
Drawn By
Finish
Promation Engineering Inc.16138 Flight Path Drive
Brooksville, Fl 34604Phone: 352-544-8436Fax: 352-544-8439
This Document is the property of ProMation Engineering,Inc. Distribution of this document without the written
consent of the owner is Strictly forbidden. Failure to comply will incur a liability for Damages.
Checked By4/8/2015
P2~P3 Dim Data Rev.
G
NO SCALE Sheet Number: 1
Material
ProMation Engineering, Inc.KHL
KHL
4/25/2013
P2_3 F07 8P22 DimData.idw
Created:
Last Checked:
Part No.
Dwg. Name
Dimensional Data for P2~P3 Actuators
Engineering Change NoticeChange Date Description Name
04.25.13 Document transferred to Inventor format KHL
11.12.13 Added rounded edges on Drive Coupling Data KHL
04.15.2014 Added tolerance on drive coupling data KHL
10.07.2014 Pushed square dimension to three decimal places KHL
REV
A
B
C
D
E
F
Dimensional Tolerances (Unless Otherwise Noted):X ± 2.5mm [X.X ± .1]
X.X ± .3mm [X.XX ± .01"]X.XX ± .13mm [X.XXX ± .005"]
ALL TOLERANCE FEATURES IN mm
G 04.08.2015 Added Isometric view of Drive Coupling and "Depth" tag for clarity KHL
H
Drive Coupling Fabrication Data
22.00 - .13.00+ mm
0.866 - 0.0050.000+ in
22.00 - .13.00+ mm
0.866 - 0.0050.000+ in
30.00 mm1.181 inDepth
30.00 mm1.181 in
229 mm9.0 in
324 mm12.8 in
211 mm8.3 in
123 mm4.8 in
180 mm7.1 in
90 mm3.5 in
287 mm11.3 in
Add 257mm
[10.1"] to allowfor coverremoval
70 mm2.8 inBHC
22 mm0.9 in
(4) M8x1.25
20mm0.8"
F07 ISO Flange
(2) 3/4" NPTEMT Entry
125 mm4.9 in
86 mm3.4 in
P3.0 Series Views(Typical)
SD
15_P
234_
0_H
V V
er M
_041
615
Use your smart phone barcode scanner app here.
16138 Flight Path Drive Brooksville, FL 34604
Phone (352) 544-8436 Fax (352) 544-8439email: [email protected]
ProMation Engineering follows a policy of continual product updates and enhancements. Our website is the best place to obtain the latest product documentation, including the wiring diagrams for these controllers. Visit us at www.promationei.com or use the QR code below to link to the site.
ProMation Product Line
PL SeriesLinear Drive
Up to 4400lbs down/up force.
P SeriesNon-Spring Return
55”lbs through 40,000”lbs.
PA~PD Series Spring Return
445”lbs through 2300”lbs.
PBU Battery Back-Up Systems
Provides battery power to drive open
P Series Exploded View (Typical)
Application Notes:1. TheseactuatorsaretobemountedONLYbetweena
horizontalanduprightposition.2. Wheninstallingconduit,usepropertechniquesforentry
into the actuator.Use drip loops to prevent conduitcondensatefromenteringtheactuator.
3. BothNPTconduitportsMUSTuseproperequipmenttoprotecttheNEMA4Xintegrityofthehousing.
4. The anti-condensate heater is to be used inALLapplications.
5. Do not install or store the actuator outdoors or in humid environments without power to the heater.
6. Useproperwiresizetopreventactuator failure(seewiresizingchart).
7. Mechanicaltravelstopsexisttopreventover-rotationformanualoverrideonly.Theyarenotintendedtostopmotordrivenrotation.
8. Do not parallel wire multiple on/off actuators together without utilizing isolation relays!Ifthisisyourintention,pleasecontactProMationEngineeringforamultipleactuatorparallelwiringdiagram.
P Series Exploded View (P2/3-120N4 unit is shown)
Switchsequencingdataisprovidedinthetablebelowtoshowthechange-of-statepointsduringtherotationoftheactuatorfromCCWtoCWandbackagain.Theredbarshowswhenthatterminalmakeswith itsrespectivecommon.
Switches1and2aresetat thefactoryandshouldNOT be changed.The INCLUDEDauxiliaryswitchesSW3&SW4areforterminals7thru12andthosesetpointsmaybemodifiedifneedbe.Whensooptioned,SW5&SW6auxiliaryswitchesareinitiallysettofunctionthesameasauxiliaryswitchesSW3&SW4.
Easilydistinguishableyellow/redposition
indicator
WormDrive
HeavyDutyDriveMotor
Easilyaccessibleswitch&camstacks
ModularControlCards
ClutchlessOverride
Handwheel
AluminumCastingNEMA4XProtection
AluminumCastingNEMA4XProtection
EpicyclicGearing
MechanicalStopScrews(2)
NEMA4XCoverSeal
Switch Logic Map and Switch/Cam Arrangement
Page4of4P3.0Series