P13656 Week 6 - SDII Update. Meeting Agenda. Variable Testing Discuss results Possible future steps Corrosion & Resistance Testing Results and possible influence on the project Cleaning Unit Update Future Steps. Variable Testing. Performed at different starting temperatures - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: P13656 Week 6 - SDII Update

P13656Week 6 - SDII Update

Page 2: P13656 Week 6 - SDII Update

Meeting Agenda• Variable Testing

o Discuss resultso Possible future steps

• Corrosion & Resistance Testingo Results and possible influence on the project

• Cleaning Unit Update

• Future Steps

Page 3: P13656 Week 6 - SDII Update

Variable Testing• Performed at different

starting temperatures• Samples were

submerged for 1.5-6 hours

• Used CTI hydrogen peroxide solution

• Coating removal was visible

Page 4: P13656 Week 6 - SDII Update

Variable Testing• Testing Schedule

Page 5: P13656 Week 6 - SDII Update

Variable Testing• Testing Data

Page 7: P13656 Week 6 - SDII Update

Visible Results• Increased time in

ultrasonic unit decreased amount of coloration

• As temperature increased, rate of stripping increased slightly

Page 8: P13656 Week 6 - SDII Update

Increase in Temp

Increase in Time

Page 9: P13656 Week 6 - SDII Update

Conductivity Testing• Measured

conductivity of peroxide solution from variable testing

• Test results obtained

• Colorimetry and correlations of base values for check

Page 10: P13656 Week 6 - SDII Update

Conductivity Testing

Page 11: P13656 Week 6 - SDII Update

Conductivity Summary• Correlation between visual results and

conductivity resultso Colorimetry also expected to support these results

• Next stepso Solution lifetime/optimal replacement period

• Potential use of conductivity to standardize solution replacement

Page 12: P13656 Week 6 - SDII Update

Corrosion Testing• Used weight loss

method

• Measuring mass change in stainless steel wire sampleso AWG 18 - 316L and

430 SS wireo 6 hour exposure

periodo Varied conditions

and solutions

Page 13: P13656 Week 6 - SDII Update

Corrosion Test Condition MethodologyStill bath (20 C) filled with:• H2O - Control• H2O2 - Baseline effect of hydrogen peroxide

Sonic bath (50 C) filled with:• H2O - Control• H2O2 - Typical operation• H2O2 + Cl (PVC shavings) - Worst case

Page 14: P13656 Week 6 - SDII Update

T = 20 C

T = 50 C

Page 15: P13656 Week 6 - SDII Update
Page 16: P13656 Week 6 - SDII Update

Significance of Corrosion Testing Results• Protection of tank integrity and estimation of

tank lifetimeo Direct vs. indirect stripping methodso Calculation of tank lifetime when used with certain

solutions

• Protection of the base metal of the producto Limit uncoated exposure time in ultrasonics

• Chlorides (PVC shavings) may have greater effect over longer time frameo Recommend using HCl for future testing

Page 17: P13656 Week 6 - SDII Update

Ultrasonic Unit• Unit has been set up in the test area and is

working properly• Heater control located on tank

Page 18: P13656 Week 6 - SDII Update

Function Generation Unit• Power selection

• Timer

• Sweep function varies power

• Overrides unit's onboard controls (excepting heat)

• User manual is on EDGE:

https://edge.rit.edu/edge/P13656/public/Phase_II_Documents/Pete/SC%20Operator's%20Guide.pdf

Page 19: P13656 Week 6 - SDII Update

Future Steps• Prepare detailed instruction manual for the

cleaner• Process conditions and optimization

• Test samples in the full-sized unit (use more realistic samples if available)

• Technical paper and poster for Imagine RIT