owner’s manual - aqua control · aqua control, inc. 1/2 hp. 50hz evolution series owners manual...
TRANSCRIPT
Aqua Control, Inc. 1/2 hp. 50Hz Evolution Series Owners Manual
Aqua Control, Inc.6A Wolfer Industrial DriveSpring Valley, IL 61362Ph: 815.664.4900 800.377.0019Fax: 815.664.4901www.aquacontrol.com
OWNER’S MANUAL
Evolution Series Fountain1/2 hp, 220-230V/50 Hz
1
Aqua Control, Inc. 1/2 hp. 50Hz Evolution Series Owners Manual
NOZZLE
FLOW STRAIGHTENER
MOUNTING FASTENERS
NOZZLE KIT
•The fountain must be connected to an individual branch circuit wire per the International Electrotechnical Commission (IEC), protected by the required time-delay fuses or circuit breaker. A three-wire, single phase 220-230V/50Hz 10 Amp circuit is required.
•The fountain is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the fountain safely. Young children should be supervised to ensure that they do not play with the fountain.
•If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
•Before connecting the fountain check that the voltage indicated on the type plate corresponds to the mains voltage.
•Under NO circumstances should anyone enter the water with the electrical equipment plugged in and/or in operation.
•NEVER run the unit out of water. It will damage the seals and create a dangerous situation for the operator.
•NEVER lift or drag the fountain by the power or light cord.
plastic bags are present, remove them with a bristle brush. Failure to keep the suction screen clear of blockages will cause low water flow and cause the fountain motor to fail. This type of failure is NOT covered under the Aqua Control, Inc. warranty.
•In freezing conditions, the fountain must be removed from the water body and stored in an area above 0°C.
ARUM #EV6-N-0.50-ARU
TIARA #EV6-N-0.50-TIA
GUSHER 4 (STATIONARY ONLY) #EV6-N-0.50-G4GUSHER 6 (STATIONARY ONLY) #EV6-N-0.50-G6
GUSHER 2 (STATIONARY ONLY) #EV6-N-0.50-G2
•The fountain suction screen should be inspected for clogging on a monthly basis. If matted weeds, leaves or
•Aqua Control. Inc. or its distributors are not liable for electrician's fees incurred for troubleshooting electrical issues.
SAFETY INSTRUCTIONS
OPTIONAL ACCESSORIES
TABLE OF CONTENTS
Stationary Assembly Instructions & Parts List 6
Torrent Pattern Conversion 7Troubleshooting Guide
Warranty Disclaimer 9
Safety 2
Assembly & Start Up Instructions 3
Maintenance & Accessory Installation 4
Evolution Parts List 5
2
CLUSTER ARCH #EV6-N-0.50-CLA
SSPIDER & ARCH #EV6-N-0.50- AR
FLEUR de LIS #EV6-N-0.50-FLEMETRO #EV6-N-0.50-MET
IMPORTANT: Reading and understanding these instructions and warranty disclaimer are necessary prior to product installation and operation.
Aqua Control, Inc. 1/2 hp. 50Hz Evolution Series Owners Manual
FOUNTAIN WITH SLOTIN FLOAT AND INSERT
MEASURE AND CUTMOORING ROPESTIE TO FLOAT
KEEPDRY
PULL FOUNTAIN TO DESIRED LOCATIONIN POND. DRIVE IN MOORING STAKES.KEEP MOTOR CORDPLUG DRY
MOORING ROPE
MOORING ROPEMOTOR CORD
SUBMERSIBLEMOTOR CORD
MOORING
THIS FACE TOWARDSFOUNTAIN
MOORING
QUICK STARTUP INSTRUCTIONS
ALIGN NOTCH IN
POWER CORD AND FOUNTAIN
3
220 VOLT RECEPTACLEPLUG FOUNTAIN INTOSTEP#5
STEP#2
STEP#1
STEP#3
STEP#4
TO CONTROL
STAKE
STAKE
TIE MOORING ROPETO MOORING STAKES
Aqua Control, Inc. 1/2 hp. 50Hz Evolution Series Owners Manual
SCRUBB WITHPLASTIC BRISTLE
BRUSH TO REMOVEDEBRIS.
SUCTIONSCREEN
PLUGGED SUCTION SCREEN
IF YOUR SUCTION SCREENBECOMES PLUGGED BY POND WEEDSOR OTHER DEBRIS.
OPTIONAL NOZZLE INSTALLATION
THROAT
REINFORCINGRING
NOZZLE
SCREWSINSERT SCREWS INNOZZLE FLANGEAND THREAD INTOTHROAT
FLANGE
INSERT FLOW STRAIGHTENERIN THROATREINFORCINGRING SIDE UP
FLOW STRAIGHTENER
MAINTENANCE AND ACCESSORY INSTALLATION
4
CAUTION!! BEFORE YOU BEGIN, DISCONNECTFROM POWER (UNPLUG FROM POWER SOURCE)
ITEM= PART= DESCRIPTION QTY1 * EV-H-KIT HARDWARE KIT (INCLUDES ITEMS 1A THRU 1G) 11A EV-H-MSP-0.75 1/4-15 X 3/4 PAN HEAD HI-LOW SCREW 41B EV-H-HN-8 8MM HEX NUT 4
1D EV-H-FW-8 8MM FLAT WASHER 41E EV-H-HHB-2.50 1/4-20 X 2 1/2 HEX HEAD CAP SCREW 11F EV-H-LW-0.25 1/4 LOCK WASHER 11G EV-H-MSP-0.75 1/4-20 X 3/4 PAN HEAD MACHINE SCREW 2
1/2HP GUSHER 2 (STATIONARY ONLY) -1/2HP GUSHER 4 (STATIONARY ONLY) -1/2HP GUSHER 6 (STATIONARY ONLY) -
3 EV-R-THROAT EVOLUTION THROAT 1
7A EV5-R-MC-050 15m MOTOR CORD 17B EV5-R-MC-100 30m MOTOR CORD 17C EV5-R-MC-175 55m MOTOR CORD 1
8 EV-R-SCREEN EVOLUTION SUCTION SCREEN 19 EV-R-FLOAT EVOLUTION FLOAT 110 EV-R-ANCHOR EVOLUTION MOORING STAKES 111 EV-R-ROPE 100' BLACK MOORING ROPE 1
REPLACEMENT MOTOR OPTIONS
NOZZLE KIT (INCLUDES NOZZLE, FLOW STRAIGHTENER & FASTENERS
8
B7A7
A6 6BB6
4
5
1C
1A
6C
7C
11
10 9
EVOLUTION PARTS LIST
1A
2A
1B
1D
3
1E
1F
1G
1C EV-H-LW-8 8MM LOCK WASHER 4
2A EV6-N-0.50-ARU 1/HP ARUM NIOZZLE KIT -2A EV6-N-0.50-CLA 1/2HP CLUSTER ARCH NOZZLE KIT -2A EV6-N-0.50-FLE 1/2HP FLEUR di LIS NOZZLE KIT -2A EV6-N-0.50-MET 1/2HP METRO NOZZLE KIT -2A EV6-N-0.50-SAR 1/2HP SPIDER & ARCH NOZZLE KIT -2A EV6-N-0.50-TIA 1/2HP TIARA NOZZLE KIT -2A * EV6-N-0.50-G22A * EV6-N-0.50-G42A * EV6-N-0.50-G6
4 EV-H-FW-PROP-2 PROPELLER WASHER 15 EV6-R-P-0.50 1/2HP PROPELLER 1
6A EV5-MA-0.50-050 1/2HP MOTOR WITH 15m OF CORD & MOLDED PLUG 16B EV5-MA-0.50-100 1/2HP MOTOR WITH 30m OF CORD & MOLDED PLUG 16C EV5-MA-0.50-175 1/2HP MOTOR WITH 55m OF CORD & MOLDED PLUG 1
5
MOTOR CORD OPTIONS (INCLUDES MOTOR CORD & MOLDED PLUG)
1
21
2
3
4
1
2
1
2
3
3
MINIMUM WATER DEPTH
STAND LEGS ASSEMBLED
MOUNTHOLE
MOUNT PATTERN
MOUNTHOLEMOUNT
ITEM NO. PART NUMBER DESCRIPTION QTY
PATTERNMAXIMUM WATER DEPTH
STAND LEGS ASSEMBLED
2 80WF-0.25 FLAT WASHER .25 18-8 S 20 1 80BH-0.25X0.63 HHCS .25-20x.625 18-8 S. 20
4 EV-S-FOOT FOOT EVOLUTION STAND 20-27 INC 4 3 80WL-0.25 LOCK WASHER .25 18-8 S. 20 STATIONARY
EVOLUTION SERIES ASSEMBLY INSTRUCTIONS6
***STATIONARY ASSEMBLY SHOWNWITH OPTIONAL LIGHT BRACKETS
LIGHTING FEATURES ARE NOT AVAILABLEFOR THE 50HZ EVOLUTION SERIES
5
5 EV-S-LEG LEG EVO STAND 20-27 INC 4
6
6 EV-S-RING CENTER RING EVO STAND 1
3 87
7
7
7 80NH-0.25-20 HEX NUT .25--20 S.S. 18-8 21
Aqua Control, Inc. 1/2 hp. 50Hz Evolution Series Owners Manual
Trouble Check Possible solutions
EVOLUTION SERIES FOUNTAINTROUBLESHOOTING GUIDE
CONVERTING YOUR EVOLUTION SERIES FOUNTAIN TO A TORRENT PATTERN
STEP 2
& LOCK WASHER.
STEP 1DISCONNECT UNIT FROM POWER.
PROP WASHER
PROP BOLT
LOCK WASHER
STEP 3REINSTALL PROP BOLT & LOCK WASHERWITHOUT PROP WASHER& TIGHTEN
Fountain does not work orstarts then stops
Not plugged in Cord must be plugged into a 3-wire outlet that isprotectd by an RCD.
RCD cuircuit breaker tripped
motor control box or the incoming power. If the RCDresets, plug the pump in to the motor control box.If the RCD trips, there may be a problem with thepump cord. Contact Aqua Control or yourdistributor for Technical Support to troubleshootthe unit.
RCD not tripped, not running Disconnect power. Check propeller for obstruction.These motors have internal overloads so, if thepropeller is jammed, the internal overload may trip.
down and reset. If the motor does not restart, theremay be other motor problems. Contact Aqua ControlTechnical Support or your distributor to troubleshootthe pump.
obstruction and remove debris.
Nozzle clogged Disconnect power, remove nozzle and check forobstruction and remove debris.
Fountain spray pattern is smaller Fountain intake clogged Disconnect power, check suction screen for
This overload may require up to 10 minutes to cool
7
If RCD will not reset, there may be a problem with the
REMOVE PROP WASHER, PROP BOLT
Reset circuit breaker. If circuit breaker will not resetor trips immediately, unplug pump and reset RCD.
AQUA CONTROLEvolution Series Fountain - International
Limited WarrantyAqua Control, Inc. warrants to the original purchaser (end user) of any Evolution Series Fountainmanufactured by Aqua Control, Inc. that any part thereof which proves to be defective in materials orworkmanship, as determined by the factory within two years from the purchase date, will be repairedor replaced at no charge with a new or remanufactured part, and returned freight prepaid. The enduser shall assume all the responsibility and expense for removal, packaging, and freight to ship to AquaControl, Inc. to determine the warranty claim and for all reinstallation expenses.
The warranty is void in cases where damage results from: improper installation, operation with noflow, continued operation with only partial flow, continued operation with obstructions that result inpump cavitation (noisy operation), improper electrical connection, improper voltage, alteration,lightning, careless handling, misuse, abuse, freezing, disassembly of motor, or failure to follow main-tenance or operating instructions. Modification or repair by an unauthorized repair facility will voidthe warranty.
In no case will Aqua Control or its distributors accept responsibility for any costs incurred by theuser during installation, removal, inspection, evaluation, repair, parts replacement, or for returnfreight. Nor will any liability be accepted for loss of use, loss of profits, loss of goodwill, for conse-quential damage, or for personal injuries to the purchaser or any person.
In the event of problems believed to be covered under warranty, it will be necessary to notify thedistributor who will then contact the factory for assistance to try and resolve the problem. If it isconcluded by Aqua Control, Inc. there may be a defect which may be covered under warranty, it willthen be the decision of Aqua Control, Inc. to ship a replacement item under warranty or deem itnecessary to issue a Return Material Authorization (RMA) to the distributor to have the product returnedto Aqua Control, Inc. for a thorough assessment.
If it is determined the product or part(s) must be returned to Aqua Control, Inc. for further assessment, theproduct or part(s) are to be returned freight prepaid, to the factory, as directed and in its original packagingor in a packaging which will prevent damage. Product that receives shipping damage will not be repaired orreplaced under warranty.
If the factory evaluation of the returned goods concludes that the failure is due to defects in materialsor workmanship, the part or parts in question will be replaced under warranty with new orremanufactured parts or, will be repaired; at the factory’s option. The warranty period for all partssupplied under warranty will terminate at the end of the original product’s warranty. All warrantyshipments from the factory will be shipped freight prepaid.
No implied warranties of any kind are made by Aqua Control, Inc. for its products, and no otherwarranties, whether expressed or implied, including implied warranties of merchantability and fitnessfor a particular purpose, shall apply. Should an Aqua Control, Inc. product prove to be defective inmaterials or workmanship, the retail purchaser’s sole remedy shall be repair or replacement of theproduct as expressly provided above.
Aqua Control, Inc.6A Wolfer Industrial Dr. Spring Valley, IL 61362
Phone: 800-377-0019 FAX 815-664-4901
9