PROJECTION (PLAN / ELEVATION)
MEMBRANE ROOFING
STUCCO
CUT (SECTION)
CONCRETE
EARTH
RIGID INSULATION
BATT INSULATION
WOOD BLOCKING
SPRAYED INSULATION
1HR WALL
CMU
BUILDING SECTION SYMBOL WALL SECTION SYMBOL
ELEVATION SYMBOLS REFERENCE KEYNOTE SYMBOL
A101
1SIM
DETAIL SYMBOL
A101
1SIM
SIMILAR, TYPICAL, OR MIRRORED REFERENCE
SIMILAR, TYPICAL, OR MIRRORED REFERENCE
SPOT DIMENSIONS
HEIGHT INDICATION (ABOVE RESPECTIVE GROUND FLOOR LEVEL ELEVATION)
0'-0"
WINDOW/ DOOR TAG SYMBOLS
WALL TAG SYMBOL
PARTITION TYPE
1,234 SF
12
ROOM NUMBER
AREA
OCCUPANT LOAD
ROOM TAG SYMBOL
Room name101
CH= 1'-0"
CEILING TAG SYMBOL
HEIGHT INDICATION (ABOVE RESPECTIVE FLOOR LEVEL ELEVATION)
DETAIL
SHEET NUMBER
SHEET NUMBER
BUILDING SECTIONNUMBER
SHEET NUMBER
DETAIL
SHEET NUMBER
BUILDING SECTION NUMBER
SHEET NUMBER
ELEVATION NUMBER
A1 A101
E3/A504
DETAIL / SHEET #E3/A
504
A101
1SIM
A101
1SIM
A101
1SIM
1
A101
1t
101 DOOR TAG
1tWINDOW TAG
DIVISION 00 -SHEET
KEYNOTES
KEYED NOTE - REFERS TO KEYNOTE LEGEND ON EACH SHEET
PROJECT LOCATION
N. HORSESHOE ST.
UNIVERSITY AVE.
S. E
SP
INA
ST
.
FRENGER ST.
PROJECT INFORMATION
MODIFICATIONS TO EXISTING BUILDINGLEVEL OF ALTERATIONS: LEVEL 1
Per IBC 2015 - 304.1OCCUPANCY CLASSIFICATION - GROUP B (UNCHANGED)
CONSTRUCTION TYPE - IIIBSPRINKLERED: YES
PROJECT GSF: 621 GSF
MEANS OF EGRESS - Per IBC 2015 CHAPTER 10
MAXIMUM COMMON PATH OF EGRESS TRAVEL DISTANCE (PER IBC TABLE 1006.2.1): B-BUSINESS 100' (SPRINKLERED)
ACTUAL COMMON PATH OF TRAVEL DISTANCE (TO FIRST FLOOR EXIT): 87'
EXISTING CLASSROOM DOOR HAS BEEN REMOVED. OCCUPANT LOAD OF SPACE IS LESS THAN 49 PERSONS. ONE EXIT ACCESS DOORWAY REQUIRED.
PER IBC 2015 TABLE 1017.2EXIT ACCESS TRAVEL DISTANCE: 300' (B OCCUPANCY-SPRINKLERED)ACTUAL EXIT TRAVEL DISTANCE: 87'
OCCUPANT LOAD FACTOR - Per IBC 2015 1004.1.2
CLASSROOM AREA - 20 NET/OCCUPANTOCCUPANT LOAD (WORK AREA):552 NSF/20 = 28 OCCUPANTS (UNCHANGED)
CODE REVIEW
PROJECT INFORMATION
RE
G
I ST ERED A RCH
I T
EC
T
ST
AT
E
OF NEWMEX
ICORICHARD HAAS
NO. 2530
This document may not be reproduced in whole or part by any means, electronic or otherwise without the explicit written permission of Desert Peak Architects P.C.. All reports, plans, specifications, computer files, field data and other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect. The Architect shall retain all common law, statutory, and other reserved rights, including the copyright thereto.
DESERT PEAK ARCHITECTS P.C.311 N MAIN STREETLAS CRUCESNEW MEXICO 88001P. 575.528.0022
SHEET NO.
SHEET TITLE
ISS
UE
:
D
C
B
A
1 3 4 52
NOT F
OR C
ONSTR
UCTIO
N
PROJECT NO.463-01
G001
COVER SHEET
11/2
1/2
019
NM
SU
CH
EM
IST
RY
BU
ILD
ING
Roo
m 2
05
Re
no
va
tion
s
11
7 N
ort
h H
ors
esho
e D
rive
La
s C
ruce
s, N
M 8
80
03
95%
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
DRAWING INDEXOWNER:NEW MEXICO STATE UNIVERSITY
CONTACT: ROBERT ESTRADA
CONSULTANTS:ELECTRICAL ENGINEERING
ARCHITECT:
DESERT PEAK ARCHITECTS, INC
1014 SOUTH MAIN STREET
LAS CRUCES, NM 88005
P. (575) 528 - 0022
CONTACT: JOSEPH FUEMMELER
VICINITY MAP
NMSU CHEMISTRY BUILDINGCOVER G-SHEETS
G001 COVER SHEET
117 NORTH HORSESHOE DRIVELAS CRUCES, NM 88003
ELECTRICAL
E1.0 SECOND FLOOR IMPROVEMENT PLAN
MATERIAL LEGEND
SYMBOL LEGEND
2015 INTERNATIONAL BUILDING CODE2015 EXISTING BUILDING CODE2015 NM COMMERCIAL CODES2015 UNIFORM MECHANICAL CODE2015 NM MECHANICAL CODE2017 NATIONAL ELECTRICAL CODE2017 NM ELECTRICAL CODE2009 INTERNATIONAL ENERGY CONSERVATION CODE
DESIGN CODES
ARCHITECTURAL
A101 FLOOR PLAN AND REFLECTED CEILING PLAN
A401 INTERIOR ELEVATIONS, SECTIONS, DETAILS AND FINISH SCHEDULE
ALPHA ENGINEERING1818 E. RIO GRANDE AVEEL PASO, TX. 79902(915) 838-9900
CONTACT: FELIX PADILLA
NMSU PROJECT #3728
ROOM 205 RENOVATIONS
Mark
Date
Description
DEMOLITION
D101 DEMOLITION PLAN AND DEMOLITION RCP
ED1.0 ELECTRICAL DEMOLITION PLAN
WAP
S
CLASSROOM205
CORRIDOR206
02 41 00.01
02 41 00.03
02 41 00.03
02 41 00.03
TYP
TYP
TYP
02 41 00.02
02 41 00.07TYP
02 41 00.0802 41 00.08
02 00 00.04 02 00 00.04
02 00 00.01
TYP
02 00 00.0202 41 00.13
02 41 00.14
02 41 00.15
02 41 00.16CLASSROOM
205 02 41 00.17
02 41 00.18 02 41 00.18
CLASSROOM205
CORRIDOR206
02 41 00.10TYP
02 41 00.06TYP
02 41 00.06TYP
02 41 00.11
02 41 00.04
02 41 00.05
02 41 00.09
02 41 00.12
21 00 00.SHTYP
A. ALL DIMENSIONS ARE TO FACE OF EXISTING MASONRY OR FINISHED FLOOR U.N.O.B. THE CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS AND
SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES.C. CONTRACTOR SHALL PROVIDE TEMPORARY BARRIERS DURING CONSTRUCTION TO
PROVIDE DUST AND DEBRIS CONTROL. CONTRACTOR TO COORDINATE BARRIER LOCATIONS WITH OWNER/ARCHITECT.
D. CONTRACTOR SHALL PROTECT ALL EXISTING TO REMAIN ITEMS WITHIN THE WORK AREA TO PREVENT DAMAGE. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING/REPLACING ANY DAMAGE DONE TO EXISTING CONDITIONS TO REMAIN.
E. CONTRACTOR SHALL COORDINATE SITE ACCESS AND STAGING AREA WITH OWNER/ARCHITECT.
F. THE CONTRACTOR SHALL REPAIR AND REPLACE ANY ITEM OR SURFACE DAMAGED BY THE WORK, OR AS REQUIRED BY NEW INSTALLATION.
G. ALL DEMOLISHED MATERIALS TO BE REMOVED FROM SITE. U.N.O.H. CONTRACTOR SHALL KEEP ALL EXISTING EXIT WAYS CLEAR AND OPEN DURING
CONSTRUCTION.I. HAZRDOUS MATERIALS - IT IS NOT EXPECTED THAT HAZARDOUS MATERIALS WILL BE
ENCOUNTERED DURING THE WORK. UPON DISCOVERY OF HAZARDOUS MATERIALS, CONTRACTOR SHALL STOP WORK AND INFORM THE OWNER/ARCHITECT
J. REFER TO ELECTRICAL AND MECHANICAL FOR FULL SCOPE OF DEMOLITION.
RE
G
I ST ERED A RCH
I T
EC
T
ST
AT
E
OF NEWMEX
ICORICHARD HAAS
NO. 2530
N
This document may not be reproduced in whole or part by any means, electronic or otherwise without the explicit written permission of Desert Peak Architects P.C.. All reports, plans, specifications, computer files, field data and other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect. The Architect shall retain all common law, statutory, and other reserved rights, including the copyright thereto.
DESERT PEAK ARCHITECTS P.C.311 N MAIN STREETLAS CRUCESNEW MEXICO 88001P. 575.528.0022
SHEET NO.
SHEET TITLE
ISS
UE
:
D
C
B
A
1 3 4 52
KEY PLAN - SECOND FLOOR
NOT F
OR C
ONSTR
UCTIO
N
PROJECT NO.463-01
D101
DEMOLITION PLAN
AND DEMOLITION
RCP
11/2
1/2
019
NM
SU
CH
EM
IST
RY
BU
ILD
ING
Roo
m 2
05
Re
no
va
tion
s
11
7 N
ort
h H
ors
esho
e D
rive
La
s C
ruce
s, N
M 8
80
03
95%
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
1/4" = 1'-0"D101A4 DEMOLITION FLOOR PLAN
1/4" = 1'-0"D101A2 DEMOLITION RCP
KEYNOTE LEGEND02 00 00.01 EXISTING WALLS TO REMAIN. PREP FOR NEW PAINT
02 00 00.02 EXISTING DOOR AND DOOR FRAME TO REMAIN. PREP FRAME FOR NEW PAINT. PAINT
02 00 00.04 EXISTING WINDOWS TO REMAIN.
02 41 00.01 DEMOLISH AND REMOVE EXISTING CARPET IN ROOM 205
02 41 00.02 DEMOLISH AND REMOVE EXISTING LECTURN. REMOVE ASSOCIATED CONDUIT AND
WIRING TO THE EXTENT POSSIBLE
02 41 00.03 REMOVE EXISTING CHALK-BOARDS IN ROOM 205. SALVAGE TO OWNER.
02 41 00.04 CAREFULLY REMOVE PROJECTOR AND MOUNTING BRACKET. SALVAGE TO OWNER.
02 41 00.05 CAREFULLY REMOVE CEILING MOUNTED SPEAKERS. SALVAGE TO OWNER
02 41 00.06 DEMOLISH AND REMOVE EXISTING CEILING DIFFUSERS AND GRILLES.
02 41 00.07 REMOVE EXISTING FLOOR MOUNTED DESKS.
02 41 00.08 REMOVE EXISTING WINDOW BLINDS.
02 41 00.09 CAREFULLY REMOVE EXISTING WIRELESS ACCESS POINT. KEEP IN CLEAN, SAFE AREA
FOR RE-USE.
02 41 00.10 REMOVE ALL TROFFER LIGHT FIXTURES. REFER TO ELECTRICAL FOR SCOPE OF
ELECTRICAL DEMOLITION
02 41 00.11 DEMOLISH AND REMOVE EXISTING ACOUSTICAL CEILING TILES AND GRID.
PATCH/REPAIR WALL WHERE GRID WAS REMOVED AS REQUIRED FOR NEW FINISHES
02 41 00.12 REMOVE EXISTING ALARM STROBE. KEEP IN CLEAN, SAFE AREA FOR RE-USE
02 41 00.13 DEMOLISH AND REMOVE EXISTING DOOR, DOOR FRAME AND HARDWARE.
02 41 00.14 DEMOLISH AND REMOVE PORTION OF EXISTING CMU PARTITION AS SHOWN. MORTAR
CAVITIES EXPOSED DURING DEMOLITION.
02 41 00.15 DEMOLISH AND REMOVE UNUSED SWITCHES IN THIS AREA - REFER TO ELECTRICAL
02 41 00.16 REMOVE AND REPLACE ALL SURFACE MOUNTED JUNCTION BOXES, RECEPTACLES AND
CONDUIT AS REQUIRED FOR NEW WALL FURRING. REFER TO ELECTRICAL
02 41 00.17 REMOVE RESILIENT BASE IN WORK AREA.
02 41 00.18 REMOVE TILE ON WINDOW SILLS. PREP SILLS FOR NEW FINISHES.
21 00 00.SH CONTRACTOR TO MODIFY LOCATION OF EXISTING SPRINKLER HEADS AS REQUIRED
BY NEW CEILING GRID LAYOUT. FIRE SUPPRESSION SYSTEM TO BE DESIGNED BY
FIRE SUPPRESSION ENGINEER AS HIRED BY CONTRACTOR. FIRE SUPPRESSION
DESIGN TO BE REVIEWED AND APPROVED BY NMSU FIRE DEPARTMENT.
GENERAL NOTES
Mark
Date
Description
PROJECT NORTH
PROJECT NORTH
CLASSROOM
205
CORRIDOR
206
CLASSROOM
205
RE
G
I ST ERED ARCH I TEC
T
S TAT
E
OF NEW MEXI CORICHARD HAAS
NO. 2530
N
This document may not bereproduced in whole or part by anymeans, electronic or otherwisewithout the explicit writtenpermission of Desert PeakArchitects P.C.. All reports, plans,specifications, computer files, fielddata and other documents andinstruments prepared by theArchitect as instruments of serviceshall remain the property of theArchitect. The Architect shall retainall common law, statutory, andother reserved rights, including thecopyright thereto.
DESERT PEAK ARCHITECTS P.C.311 N MAIN STREETLAS CRUCESNEW MEXICO 88001P. 575.528.0022
SHEET NO.
SHEET TITLE
ISS
UE
:
D
C
B
A
1 3 4 52
KEY PLAN - SECOND FLOOR
NOT FOR CONSTRUCTIO
N
PROJECT NO.463-01
ELECTRICALDEMOLITION
PLAN
NM
SU
C
HE
MIS
TR
Y B
UIL
DIN
G
Room
205 R
enova
tions
117 N
ort
h H
ors
eshoe
Drive
Las
Cru
ces,
NM
88003
Mar
kD
ate
Des
crip
tion
SECOND FLOOR ELECTRICAL DEMOLITION
DEMOLITION PLAN KEYED NOTES:
11/1
1/2
019
50%
ARCH
ITECTU
RAL
ED1.0
DEMOLITION GENERAL NOTES:
ELECTRICAL DEMOLITION SYMBOL LEGEND
D
S
WAP
S
A. REFER TO REFLECTED CEILING PLAN FOR CEILING-MOUNTED FIXTURES AND EQUIPMENT. COORDINATE WITH ELECTRICAL DRAWINGS.
B. ALL DIMENSIONS ARE TO FACE OF EXISTING MASONRY OR FINISHED FLOOR U.N.O.C. PROVIDE IN-WALL BLOCKING FOR ALL WALL MOUNTED ACCESSORIES.D. ALL CEILING MOUNTED EQUIPMENT INCLUDING FIRE ALARM AND FIRE SUPPRESSION
SYSTEMS ARE TO LIE ON THE CENTER OF CEILING GRIDS U.N.O. ALL CEILING MOUNTED EQUIPMENT TO BE SUSPENDED FROM STRUCTURE.
151413
B
C
D
F
G
CLASSROOM205
CORRIDOR206
A4 A401
A2
A401
B2
A40
1
B4 A401
11 00 00.TV
02 00 00.02
02 00 00.04 02 00 00.04
09 68 00.C
1
6'-0"
+60"
10 11 00.GMB
10 11 00.GMB
10 11 00.GMB
26 00 00.R
26 00 00.R
26 00 00.D
26 00 00.D
26 00 00.R26 00 00.S
26 00 00.RE26 00 00.RE
10 14 00.RIS
26 00 00.R2
2
2
2
2
09 68 00.TS A401
C2
10 26 01.CG
09 65 00.RBF
09 21 16.GBS 09 21 16.GBS
CLASSROOM205
CORRIDOR206
12 24 00.RS 12 24 00.RS
CH=10' - 6"
CH=8' - 0"
09 51 00.AT22
26 00 00.LF
09 21 16.CB3
7' - 10"
A
B
A
A A
21 00 00.SH
21 00 00.S
TYP
11 00 00.WAP
23 00 00.DTYP
23 00 00.R
C1
A401
TYP
24" X 24" ACOUSTIC CEILING TILE
HVAC RETURN AIR GRILLE - REF MECHANICAL SHEETS.
HVAC SUPPLY AIR GRILLE - REF MECHANICAL SHEETS.
GYPSUM BOARD CEILING TAPE, TEXTURE AND PAINT
2X2 LAY-IN LIGHT FIXTURE - REF. ELECTRICAL SHEETS
SPRINKLER HEAD - ADJUST EXISTING SPRINKLER PER NEW CEILING LAYOUT
CEILING MOUNTED STROBE LIGHT
1. ALL SPRINKLER HEADS, ELECTRICAL COMMUNICATIONS, AND LIFE SAFETY DEVICES TO FALL IN THE CENTER OF CEILING TILES.
2. START CEILING GRID LAYOUT IN THE CENTER OF ROOM AND WORK OUTWARD, UNLESS NOTED OR DIMENSIONED OTHERWISE.
3. CONTRACTOR SHALL COORDINATE WITH ALL ELECTRIAL ENGINEERING SHEETS FOR ADDITIONAL CEILING MOUNTED EQUIPMENT.
A. THE FIRE PROTECTION SYSTEM IS DESCRIBED IN THESE DOCUMENTS AS A PERFORMANCE SPECIFICATION ONLY. FIRE PROTECTION INFORMATION INCLUDED ON ALL DOCUMENTS INCLUDING PLANS AND SPECIFICATIONS ARE PROVIDED FOR INFORMATION ONLY AND SHALL NOT BE CONSIDERED DETAILED CONSTRUCTION DOCUMENTS. ACTUAL DISIGN OF THIS SYSTEM (INCLUDING MODIFICATIONS AND UPGRADES TO THE FIRE SUPPRESSION) SHALL BE THE RESPONSIBILITY OF THE FIRE PROTECTION SUB-CONTRACTOR/DESIGNER AS HIRED BY THE GENERAL CONTRACTOR
B. THE FIRE PROTECTION COMPONENTS AND SYSTEMS COMLPLY WITH APPLICABLE AHJ, CITY, STATE, AND FEDERAL FIRE PROTECTION CODES AND AUTHORITIES. COORDINATION AND APPROVALS BY THESE CODE AUTHORITIES SHALL BE THE RESPONSIBILITY OF THE FIRE PROTECTION CONTRACTOR/DESIGNER.
C. SIZES ARE NOT SHOWN FOR FIRE PROTECTION PIPE AND FITTINGS. ACTUAL SIZES SHALL BE DETERMINED BY THE FIRE PROTECTION DESIGNER/CONTRACTOR/ENGINEER.
D. THE FIRE PROTECTION ZONES AND THEIR OCCUPANCY TYPES FOR THIS BUILDING SHALL BE DEFINED BY NFPA. THE FIRE SYSTEM(S) SHALL BE COORDINATED WITH ARCHITECTURAL, STRUCTURAL, AND ALL OTHER TRADES TO PROPERLY PROTECT EACH ZONE TYPE. DESIGNER/SUB-CONTRACTOR SHALL CONFORM TO NFPA AND LOCAL FIRE DEPARTMENT REQUIREMENTS.
E. HYDRAULIC DESIGN SHALL MAINTAIN A MINIMUM OF A 10 PSI SAFETY FACTOR FROM WATER SUPPLY DATA. CONTRACTOR SHALL VERIFY EXISTING SYSTEM CONFIGURATION, PIPE ROUTING AND HEAD LOCATIONS. CONTRACTOR SHALL DETERMINE COVERAGE.
FINISHED FLOOR
CEILING LINE
EXISTING CONCRETE DECK
6" CONCRETE MASONRY UNIT 1 5/8" METAL STUD FURRING WALL WITH
GYPSUM WALL BOARD (ONE SIDE)
TERMINATE GYP 6" ABOVE CEILING - TYP
ONE SIDE
RESILIENT BASE
CONCRETE MASONRY UNIT(S)6"
1 2
GYPSUM BOARD 5/8",STANDARD - TAPE AND
TEXTURE WITH SMOOTH, LEVEL5 FINISH - PAINT
1-5/8" METAL STUDS, 16" OCMINIMUM
6"
RESILIENT BASEFLOOR LINE
PAINT NEW CMU WALL ON SIDEOF CORRIDOR TO MATCH
EXISTING
6" CMU BOND BEAM AT 8' A.F.FAND 12' A.F.F - FULLYGROUTED WITH (1) #4
CONTINUOUS REBAR TIED INTOEXISTING CMU WITH EPOXY.
RE
G
I ST ERED A RCH
I T
EC
T
ST
AT
E
OF NEWMEX
ICORICHARD HAAS
NO. 2530
N
This document may not be reproduced in whole or part by any means, electronic or otherwise without the explicit written permission of Desert Peak Architects P.C.. All reports, plans, specifications, computer files, field data and other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect. The Architect shall retain all common law, statutory, and other reserved rights, including the copyright thereto.
DESERT PEAK ARCHITECTS P.C.311 N MAIN STREETLAS CRUCESNEW MEXICO 88001P. 575.528.0022
SHEET NO.
SHEET TITLE
ISS
UE
:
D
C
B
A
1 3 4 52
KEY PLAN - SECOND FLOOR
NOT F
OR C
ONSTR
UCTIO
N
PROJECT NO.463-01
A101
FLOOR PLAN AND
REFLECTED CEILING
PLAN
11/2
1/2
019
NM
SU
CH
EM
IST
RY
BU
ILD
ING
Roo
m 2
05
Re
no
va
tion
s
11
7 N
ort
h H
ors
esho
e D
rive
La
s C
ruce
s, N
M 8
80
03
95%
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
GENERAL NOTES
KEYNOTE LEGEND02 00 00.02 EXISTING DOOR AND DOOR FRAME TO REMAIN. PREP FRAME FOR NEW PAINT. PAINT
02 00 00.04 EXISTING WINDOWS TO REMAIN.
04 20 00.CB6 CONCRETE MASONRY UNIT(S) 6"
04 27 31.BB 6" CMU BOND BEAM AT 8' A.F.F AND 12' A.F.F - FULLY GROUTED WITH (1) #4 CONTINUOUS
REBAR TIED INTO EXISTING CMU WITH EPOXY.
09 21 16.CB3 5/8" GYPSUM BOARD CEILING . TAPE & TEXTURE TO MATCH EXISTING. PAINT
09 21
16.GB58
GYPSUM BOARD 5/8", STANDARD - TAPE AND TEXTURE WITH SMOOTH, LEVEL 5 FINISH -
PAINT
09 21 16.GBS PROVIDE 5/8" GYPSUM BOARD AT JAMBS, SILL AND HEAD OF WINDOW OPENING SURROUND.
TERMINATE GYP WITH CASING BEAD AND PROVIDE CONTINUOUS SEALANT WHERE NEW
GYPSUM BOARD MEETS EXISTING WINDOW FRAME. - TAPE AND TEXTURE WITH SMOOTH,
LEVEL 5 FINISH - PAINT.
09 21 16.MS1 1-5/8" METAL STUDS, 16" OC MINIMUM
09 51 00.AT22 SUSPENDED TILE CEILING, 2X2 - REFER TO ROOM FINISH LEGEND FOR TILE DESIGNATION
09 65 00.RB RESILIENT BASE
09 65 00.RBF REPLACE MISSING/DAMAGED FLOORING IN CORRIDOR ALONG NEW CMU PARTITION WALL.
PROVIDE BASE AT NEW CMU PARTITION TO MATCH EXISTING.
09 68 00.C 24" X 24" CARPET TILE
09 68 00.TS ALUMINUM TRANSITION STRIP.
09 90 00.P1 PAINT NEW CMU WALL ON SIDE OF CORRIDOR TO MATCH EXISTING
10 11 00.GMB GLASS MARKER BOARD - 4' HEIGHT
10 14 00.RIS REPLACE EXISTING ROOM IDENTIFICATION SIGNAGE WITH NEW SIGNAGE PER NMSU
STANDARD. PROVIDE BRAILLE @ 60" A.F.F. AND INTERNATIONAL SYMBOL OF ACCESSIBILITY
WHERE REQUIRED
10 26 01.CG CORNER GUARD, TYPICAL AT ALL EXTERIOR CORNERS - REFER TO SPECS
11 00 00.TV 80" TELEVISION WITH FULL MOTION TV MOUNT - OWNER PROVIDED, CONTRACTOR
INSTALLED. TELEVISION MOUNT BASIS OF DESIGN: SANUS PREMIUM SERIES FULL-MOTION
TV WALL MOUNT MODEL NO. BLF213-B1. REFER TO ELECTRICAL
11 00 00.WAP WIRELESS ACCESS POINT - N.I.C. - OWNER PROVIDED, OWNER INSTALLED.
12 24 00.RS MANUAL DOUBLE ROLLER SHADES WITH SOLAR SCREEN AND BLACKOUT SHADE
COMBINATON. BASIS OF DESIGN - SOL-R-SHADE AS MANUFACTURED BY DFB SALES INC.
FABRICS: G 10-B SOUND ABSORBING FABRIC AND G-80 BLACKOUT FABRIC. INSTALL SIDE BY
SIDE WITH FASCIA BRACKET AS PROVIDED BY MANUFACTURER
21 00 00.S FIRE ALARM STROBE LIGHT. CONNECT TO EXITING FIRE ALARM CIRCUITRY. REFER TO
ELECTRICAL. FIRE ALARM STROBE LIGHT LOCATION TO BE APPROVED BY NMSU FIRE
DEPARTMENT
21 00 00.SH CONTRACTOR TO MODIFY LOCATION OF EXISTING SPRINKLER HEADS AS REQUIRED BY NEW
CEILING GRID LAYOUT. FIRE SUPPRESSION SYSTEM TO BE DESIGNED BY FIRE SUPPRESSION
ENGINEER AS HIRED BY CONTRACTOR. FIRE SUPPRESSION DESIGN TO BE REVIEWED AND
APPROVED BY NMSU FIRE DEPARTMENT.
23 00 00.D NEW MECHANICAL DIFFUSER - REFER TO SCHEDULE
23 00 00.R NEW RETURN GRILLE - REFER TO SCHEDULE
26 00 00.D DATA PORT - REFER TO ELECTRICAL
26 00 00.LF LIGHT FIXTURE - REFER TO ELECTRICAL
26 00 00.R ELECTRICAL RECEPTACLE - REFER TO ELECTRICAL
26 00 00.RE PROVIDE JUNCTION BOX EXTENSION AS REQUIRED FOR NEW GYPSUM PLASTER FINISH.
PROVIDE AND INSTALL NEW RECEPTACLE OUTLET AND NEW FACEPLATE TO EXISTING
CIRCUITRY
26 00 00.S ELECTRICAL SWITCH - REFER TO ELECTRICAL
PROJECT NORTH
1/4" = 1'-0"A101A4 SECOND FLOOR PLAN
1/4" = 1'-0"A101A2 SECOND FLOOR REFLECTED CEILING PLAN
PROJECT NORTH
RCP LEGEND
Mark
Date
Description
DIFFUSER AND GRILLE SCHEDULEType Mark Manufacturer Model Description
A TITUS OMNI SUPPLY DIFFUSER; STANDARD FINISH - #26 WHITE; STEEL CONSTRUCTION; 24" X 24" FACE;LAY-IN; CONTRACTO TO FIELD VERIFY REQUIRED NECK SIZE. CONNECT TO EXISTING DUCTWORK. INSTALL PER MANUFACTURER'S RECOMMENDATIONS
B TITUS 23RL RETURN GRILLE; STANDARD FINISH - #26 WHITE; STEEL CONSTRUCTION; 24" X 24" FACE; 45DEGREE DEFLECTION, 3/4" BLADE SPACING; INSTALL BLADES PARALLEL TO LONGDIMENSION OF ROOM. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
FIRE SUPPRESSION GENERAL NOTES
RCP GENERAL NOTES
1/2" = 1'-0"A101C2 WALL PARTITION TYPES
02 00 00.02 02 00 00.03TYP
5'-0
"
11 00 00.TV
4'-0"
26 00 00.R
26 00 00.D
04 20 00.CB6
2'-6
"
10 11 00.GMB
TYP
10'-0"26 00 00.R
26 00 00.D
EQEQ
10'-0"5'-0"
6" 5'-6"
2'-6
"4
'-0
"
10'-0" 5'-0"10"
09 21 16.GB5826 00 00.R
26 00 00.D
10 11 00.GMB
09 21 16.GB58
26 00 00.RE3'-0" 6"
12 24 00.RS
EQ EQ
2'-6
"4
'-0
"
10 11 00.GMB
09 21 16.GB58
26 00 00.RE
26 00 00.D
26 00 00.R
26 00 00.S
10'-0" 5'-0"
02 00 00.0402 00 00.04
02 00 00.03
12 24 00.RS12 24 00.RS
TYP
26 00 00.R
A. ALL DIMENSIONS ARE TO FACE OF EXISTING MASONRY OR FINISHED FLOOR. B. REFERENCE SHEET G005 FOR ACCESSIBLE MOUNTING HEIGHTSC. PROVIDE IN WALL BLOCKING FOR ALL WALL MOUNTED ACCESSORIES.
SECOND FLOOR12' - 0"
6"
09 21 16.MS3
09 21 16.GB58
09 21 16.ST
6"
02 00 00.04
09 65 00.RB
09 21 16.GB58
09 21 16.MS1
06 41 00.B
06 41 00.B
09 21 16.GB58
09 21 16.CB1
09 21 16.CB1
09 51 00.AT22
09 21 16.CB1
6"
09 21 16.MS1
2'-7 3/4"
09 21 16.MS3
06 41 00.B
12 24 00.RS
07 90 05.S
07 90 05.S
09 21 16.GBS
TYP
EXISTING CMU WALL TO REMAIN
EXISTING CMU WALL TO REMAIN
1' X 1/2" DOWELS AT 16" O.C. FROM F.F. TO B.O. DECK. EPOXY INTO EXISTING CMU.
GROUT CELLS SOLID
GROUT CELLS SOLID
1' X 1/2" DOWELS AT 16" O.C. FROM F.F. TO B.O. DECK.
EPOXY INTO EXISTING CMU.
BACKER ROD AND ELASTOMERIC SEALANT - MASTERSEAL NP 1 OR EQUAL
BACKER ROD AND ELASTOMERIC SEALANT -
MASTERSEAL NP 1 OR EQUAL
6" CMU WALL (NEW)
GYP: 5/8" GYPSUM CEILING BOARD - TAPE AND TEXTURE WITH SMOOTH, LEVEL 5 FINISH - PAINT
E: EXISTING WALL FINISH TO REMAIN. PAINT NEW CMU PARTITION TO MATCH EXISTING
CPT: 24" X 24" CARPET TILE: BASIS OF DESIGN - CLASS ACT 312 BRILLIANT HIGH MARKS AS MANUFACTURED BY MOHAWK
EF: EXISTING FLOORING TO REMAIN - REPAIR/REPLACE DAMAGED OR MISSING PORTIONS OF FLOORING AS REQUIRED TO MATCH EXISTING
*NOTE: PROVIDE ALUMINUM TRANSITION STRIPS AT JOINTS BETWEEN DISSIMILAR MATERIALS.
RB: 4" RUBBER COVED BASE - BASIS OF DESIGN - TARKETT #32 - PEBBLEEB: EXISTING WALL BASE TO REAMIN. PROVIDE NEW WALL BASE ALONG NEW CMU
PARTITION TO MATCH EXISTING BASE IN CORRIDOR
A22: 2' X 2' ACOUSTICAL TILE CEILINGGYP: 5/8" GYPSUM CEILING BOARD - TAPE AND TEXTURE WITH SMOOTH, LEVEL 5 FINISH
- PAINT E: EXISTING CEILING FINISH TO REMAIN. PATCH PAINT AS REQUIRED TO MATCH
EXISTING
CEILING FINISH
FLOOR FINISH
WALL BASE
WALL FINISH
RE
G
I ST ERED A RCH
I T
EC
T
ST
AT
E
OF NEWMEX
ICORICHARD HAAS
NO. 2530
This document may not be reproduced in whole or part by any means, electronic or otherwise without the explicit written permission of Desert Peak Architects P.C.. All reports, plans, specifications, computer files, field data and other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect. The Architect shall retain all common law, statutory, and other reserved rights, including the copyright thereto.
DESERT PEAK ARCHITECTS P.C.311 N MAIN STREETLAS CRUCESNEW MEXICO 88001P. 575.528.0022
SHEET NO.
SHEET TITLE
ISS
UE
:
D
C
B
A
1 3 4 52
NOT F
OR C
ONSTR
UCTIO
N
PROJECT NO.463-01
A401
INTERIOR
ELEVATIONS,
SECTIONS, DETAILS
AND FINISH
SCHEDULE
11/2
1/2
019
NM
SU
CH
EM
IST
RY
BU
ILD
ING
Roo
m 2
05
Re
no
va
tion
s
11
7 N
ort
h H
ors
esho
e D
rive
La
s C
ruce
s, N
M 8
80
03
95%
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
KEYNOTE LEGEND02 00 00.02 EXISTING DOOR AND DOOR FRAME TO REMAIN. PREP FRAME FOR NEW PAINT. PAINT
02 00 00.03 EXISTING CMU WALL TO REMAIN.
02 00 00.04 EXISTING WINDOWS TO REMAIN.
04 20 00.CB6 CONCRETE MASONRY UNIT(S) 6"
06 41 00.B BLOCKING
07 90 05.S CONT. SEALANT
09 21 16.CB1 GYPSUM CASING BEAD
09 21 16.GB58 GYPSUM BOARD 5/8", STANDARD - TAPE AND TEXTURE WITH SMOOTH, LEVEL 5 FINISH -
PAINT
09 21 16.GBS PROVIDE 5/8" GYPSUM BOARD AT JAMBS, SILL AND HEAD OF WINDOW OPENING SURROUND.
TERMINATE GYP WITH CASING BEAD AND PROVIDE CONTINUOUS SEALANT WHERE NEW
GYPSUM BOARD MEETS EXISTING WINDOW FRAME. - TAPE AND TEXTURE WITH SMOOTH,
LEVEL 5 FINISH - PAINT.
09 21 16.MS1 1-5/8" METAL STUDS, 16" OC MINIMUM
09 21 16.MS3 3-5/8" METAL STUDS, 16" OC MINIMUM
09 21 16.ST SLIP TYPE HEAD JOINT
09 51 00.AT22 SUSPENDED TILE CEILING, 2X2 - REFER TO ROOM FINISH LEGEND FOR TILE DESIGNATION
09 65 00.RB RESILIENT BASE
10 11 00.GMB GLASS MARKER BOARD - 4' HEIGHT
11 00 00.TV 80" TELEVISION WITH FULL MOTION TV MOUNT - OWNER PROVIDED, CONTRACTOR
INSTALLED. TELEVISION MOUNT BASIS OF DESIGN: SANUS PREMIUM SERIES FULL-MOTION TV
WALL MOUNT MODEL NO. BLF213-B1. REFER TO ELECTRICAL
12 24 00.RS MANUAL DOUBLE ROLLER SHADES WITH SOLAR SCREEN AND BLACKOUT SHADE COMBINATON.
BASIS OF DESIGN - SOL-R-SHADE AS MANUFACTURED BY DFB SALES INC. FABRICS: G 10-B
SOUND ABSORBING FABRIC AND G-80 BLACKOUT FABRIC. INSTALL SIDE BY SIDE WITH
FASCIA BRACKET AS PROVIDED BY MANUFACTURER
26 00 00.D DATA PORT - REFER TO ELECTRICAL
26 00 00.R ELECTRICAL RECEPTACLE - REFER TO ELECTRICAL
26 00 00.RE PROVIDE JUNCTION BOX EXTENSION AS REQUIRED FOR NEW GYPSUM PLASTER FINISH.
PROVIDE AND INSTALL NEW RECEPTACLE OUTLET AND NEW FACEPLATE TO EXISTING
CIRCUITRY
26 00 00.S ELECTRICAL SWITCH - REFER TO ELECTRICAL
1/2" = 1'-0"A401A4 CLASSROOM 205 LOOKING NORTH
1/2" = 1'-0"A401A2 CLASSROOM 205 LOOKING EAST
1/2" = 1'-0"A401B2 CLASSROOM 205 LOOKING WEST
1/2" = 1'-0"A401B4 CLASSROOM 205 LOOKING SOUTH
GENERAL NOTES
Mark
Date
Description
1/2" = 1'-0"A401C1 WALL SECTION
1 1/2" = 1'-0"A401C2 CMU CONNECTION DETAIL
SECOND FLOOR ROOM FINISH SCHEDULEROOM ID FLOOR WALLS CEILING
ROOM NO ROOM NAME FLOOR BASE NORTH SOUTH EAST WEST MATL
205 CLASSROOM CPT RB GYP GYP GYP GYP GYP
206 CORRIDOR EF EB E E E E E
ROOM FINISH LEGEND
CLASSROOM
205
CORRIDOR
206
RE
G
I ST ERED ARCH I TEC
T
S TAT
E
OF NEW MEXI CORICHARD HAAS
NO. 2530
N
This document may not bereproduced in whole or part by anymeans, electronic or otherwisewithout the explicit writtenpermission of Desert PeakArchitects P.C.. All reports, plans,specifications, computer files, fielddata and other documents andinstruments prepared by theArchitect as instruments of serviceshall remain the property of theArchitect. The Architect shall retainall common law, statutory, andother reserved rights, including thecopyright thereto.
DESERT PEAK ARCHITECTS P.C.311 N MAIN STREETLAS CRUCESNEW MEXICO 88001P. 575.528.0022
SHEET NO.
SHEET TITLE
ISS
UE
:
D
C
B
A
1 3 4 52
KEY PLAN - SECOND FLOOR
NOT FOR CONSTRUCTIO
N
E1.0
FLOOR PLAN ANDREFLECTED CEILING
PLAN
11/1
1/2
019
NM
SU
C
HE
MIS
TR
Y B
UIL
DIN
G
50%
ARCH
ITECTU
RAL
Mar
kD
ate
Des
crip
tion
SECOND FLOOR IMPROVEMENT PLAN
LIGHTING PLAN KEYED NOTES:
Room
205 R
enova
tions
117 N
ort
h H
ors
eshoe
Drive
Las
Cru
ces,
NM
88003
PROJECT NO.463-01
FIXTURE SCHEDULE
ELECTRICAL SYMBOL LEGEND
GENERAL NOTES: