    To: OilView Users

    Subject: OilView News #3: "Consumables"

    This memo provided to share OilView information among OilView minilab users.

    If you know others who want to be added to this news letter, just "reply" to me and

    let me know their email address. If you want to be taken off of this news lettermailing, please respond and I will take your name off the list.Please respond to me with your questions, comments, and suggestions.Please send me your case histories so I can share them with the user group.

    Ray Garveyemail: "[email protected]"

    Today's subjects: "Consumables"

    OilView Consumables. Many times OilView users want to shop around to get the best buyfor consumable materials such as bottles, tubing, CO2 cartridges, and calibration fluids.Here is the information I have compiled -- see "Consum1.doc" below. If any of you haveother sources, let me know and I will pass out the word.

    By the way, I am very happy using "Lamp Oil" from Walmart for diluted sample testingusing the 5100, 51PC, and 51WD. To test the cleanliness of lamp oil or kerosene, simplytest it all by itself and expect clean results. You can install a final 0.75 micron filterelement to remove particles if you want. To do this, some like to use a stainless steelgarden sprayer with a Millipore filter adapter on the outlet. Color in the lamp oil has noeffect on results. I do think it's a good idea to avoid using scented lamp oil -- unlesseverybody agrees on the fragrance. All-in-all, unscented lamp oil is my new favorite.

    From: Ray Garvey, CSI (865) 675-3100 fax, [email protected]: OilView MiniLab UsersDate: Mar 10, 2000

    Subject: CONSUMABLES AND OTHER SUPPLIES FOR OILVIEWMINILABS

    Calibration fluids:CSI Part # Description Shelf LifeA510050 51DV cal fluid 8 pack UnlimitedA510051 5100 most oils sensor calib (Fluids A & B) 5 yr unopened, 90 daysopenA510052 5100 phosphate ester sensor calib (Fluids B & C) 5 yr unopened, 90 daysopen09600 Particle Counter ACFTD cal fluid, 400 ml bottle 1 year09610 Particle Counter ultraclean kerosene, 1 L bottle Unlimited

    4 ounce PET or HDPE bottle w/ lid (PET bottle Same as CSI Part#10698)Distribution Specalists Inc. 45449 Severn Way #179 Sterling, VA 22170(703)430-8986 (fax -9317)

    4 ounce PET or HDPE BottlesEasy Vac Inc, 7922 Nubbins Ridge Rd., Knoxville, TN 37919talked to Earl Johnson 5/1/96, (423) 691-7510201-04 I HDPE Qty 500 cost $260/1000

  • 7/27/2019 OVN 03 Consumables.doc

    2/5

    Qty 50 cost $17.75/50201-04 HDPE sturdy Qty 50 cost $19.40/50

    Qty 500 cost $290/1000201-04 C clear (PET) Qty 50 cost $31.40/50

    Qty 550 cost $536/1000

    4 ounce HDPE bottles w/ lidThompson Pump Company sells500 at a time $0.29 per Martha on 5/1/96 at phone (214) 352-6334

    1, 2, 4, and 16 oz HDPE bottles w/ 38mm lids (Supplier to Thompson)Midland Manufacturing Company, Monroe, Iowa (515) 259-2625500/pack min order 266.98/1000 includes the cap (prices only for the 4 ouncebottles)talked to Marianne on 5/1/96. 5/7/96 - I received 1, 2, 4, and 16 oz bottles w/38mm lids, they look good and work well, although they are dirty on the inside. Allbottles have ribs. The 1, 2, and 4 ounce bottles all work with the PC or Analzyer.

    To use them with the FW, simply remove the collar over the light sensors. The 16ounce bottle works well for either the Analzyer or the FW (without collar).

    4 ounce HDPE bottles

    (Note that Acorn is the onlysupplier ofcertified clean bottles for accurateparticle counting.)Acorn Industries (313) 261-294011844 Brookfield AveLivonia, MI 48150

    $1.41each certified clean$0.52 each without certification for cleanliness (i.e., as manufactured)

    talked to Ed Schiller 5/1/96

    Tubing NEWAGE 01PENAT5, (same as CSI Part#92079)Easy Vac Inc., 7922 Nubbins Ridge Rd., Knoxville, TN 37919, (423)691-7510

    Manual Sple Pump ACCU-VAC #1991, (same as CSI Part#92610)Thompson Pump Co., 2682 Myrtle Springs Ave., Dallas, TX 75220 (800)235-7867

    CO2 CARTRIDGE FOR OilView PARTICLE COUNTER:

    Here are the sources for CSI P/N 09514, which actually calls out either a 60gram or 68 gram, 5/8" threaded CO2 cartridge:

    Source Part Number Last Cost------ ----------- ---------

    Leland Limited, Inc. P/N 87203 (60 gram) or $12.80 eaBox 382 P/N 87207 (68 gram)Bedminster, NJ 07921Attn: Lee Stanford

  • 7/27/2019 OVN 03 Consumables.doc

    3/5

    Southern FluidPower, Inc. Parker Hannifin P/N 601895 $195 per2900 Dodds Ave. (68 gram 5/8" threaded, 10-packChattanooga, TN 37407 bought from Leland?)Attn: Luke Winder

    Source for calibration oils for Digital Viscometer

    Cannon Instrument Company Phone : (814) 353-80002139 High Tech RoadState College, PA 16803

    Visc 40C Visc 100C Cannon Part #S20 17.94 3.740 9729-C35S60 54.10 7.692 9727-C40S200 180.3 16.76 9727-C45

    N350 310.3 23.84 9727-C47N1000 941.2 79.74 9727-C52All standards come in a 1 pint bottle at a cost of $45 per bottle.Delivery time was 2 weeks.

    VACUUM CHAMBER:Available from Fisher Scientific 1-800-766-7000 (fax 1-800-926-1166)

    Vacuum Desiccator, Polycarbonate with Silicone O-RingFisher No. 08-642-7 $59.00

    Or Nalge No. 5310-0250

    Helpful accessory for testing is a10 inch (230 mm) metal plate for desiccator:Fisher No 08-642-10 $36.80Or Nalge No. 5312-230GAST PRESSURE/VACUUM PUMP:Available from Fisher Scientific 1-800-766-7000 (fax 1-800-926-1166)

    115 V A/C, pressure to 100 psig (689 kPag), vacuum to 25 in. Hg (84 kPag),free air flow 37 L/min (1.3 cfm)

    Fisher No. 01-092-25 $360.00Or Gast No. 1HAB25BM100X

    230 V 50 Hz A/C, pressure to 100 psig (689 kPag), vacuum to 25 in. Hg (84kPag), free air flow 34 L/min (1.2 cfm)Fisher No. 01-092-26 $474.00Or Gast No. 1HAE25AM104X

  • 7/27/2019 OVN 03 Consumables.doc

    4/5

    ULTRASONIC BATH FOR PARTICLE COUNT SAMPLE PREPARATION

    Cole Palmer Instrument Company7425 North Oak Park AvenueNiles, Illinois 60714

    1-800-323-434, (708) 647-7600, FAX (708) 647-9660

    Ultrasonic Cleaner 115 V AC H-08890-00$270 (same as CSI #93415)220 V AC H-08890-05$355

    Tray insert for samples H-08850-42$43 (same as CSI #75000)

    SUPPLIES FOR WEAR DEBRIS ANAYSIS

    The Millipore part numbers follow:Slides PDMA 047 008 micron patches SCWP 025 00

    3 micron patches SCWP 025 00

    To place an order call 1-800-645-5476

  • 7/27/2019 OVN 03 Consumables.doc

    5/5

    MESH FOR 51WD

    The part number for that item is D23628 and the price is $5. To placean order, call Darla Adcock at (865) 675-2400 ext. 2312